This document contains questions and answers regarding a solicitation for the cyclic replacement of a chain-link fence. The solicitation calls for a 9 gauge galvanized wire fence with 1-5/8 inch SCH40 top rail and bracing, 2 inch SCH40 line posts, 2-1/2 inch SCH40 terminal posts, and 4 inch SCH40 gate posts. The fence is to be straight without turns. Barbed wire is not required at the top of the fence. The solicitation was issued by the Department of the Interior National Park Service Southeast Region for work at MOCR under solicitation number 140P5323Q0045.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers

140P5323Q0045

1. Question: What is the gauge of the wire needed for the chain link fence?

Answer: 9 ga. Galvanized Wire

2. Question: What is the thickness of the pipes used in the fence?

Answer: 1-5/8" SCH40 Top Rail & Bracing

2" SCH40 Line Posts

2-1/2" SCH40 Terminal Posts

4" SCH40 Gate Posts

3. Question: How many times does the fence stop and turn?

Answer: The fence is straight and does not turn.

4. Question: Is barbed wire required at the top of the fence?

Answer: No, barbed wire is not required on top of the fence.