Question 1 Drawing.pdf

PDF 431 KB Posted

Attached to
Construction: CFMO Building 1707 HVAC Renovations
Solicitation number
CRFQ 0603 ADJ2600000022 4
Issued by
Kanawha County, West Virginia

About this file

This is an architectural construction drawing for HVAC renovations at CFMO Building 1707 for the West Virginia Army National Guard. The document is a Reflected Ceiling Plan (Sheet A2.01) prepared by The Thrasher Group, Inc., dated June 26, 2026, and shows the ceiling layout and coordination requirements for the HVAC renovation project located at 1285 Aviation Drive, Williamstown, West Virginia 26187. The drawing specifies contractor responsibilities including removal and reinstallation of existing acoustical ceiling tile and grid at the same height, as well as removal and reinstallation of all ceiling-mounted items such as lights, detectors, security systems, and fire alarm equipment in their original locations.

The construction document requires coordination between the contractor and MEP (mechanical, electrical, and plumbing) drawings to ensure proper placement of new ductwork and HVAC equipment. The drawing is marked as construction documents and includes standard copyright protections indicating the plans are the sole property of The Thrasher Group, Inc. No specific pricing, timeline, or contracting terms are detailed within this architectural drawing; it serves as a technical specification document for the ceiling and HVAC-related work on the renovation project.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

No. 5742

COOK

WILLIAM R.

S T A T E

O F W E S T

V

I R G I N I A

A R C H I T E

C T

SHEET No.

C

AD

F

IL

E:

PROJECT No.

DRAWN:

CHECKED:

DATE:

DATE:

LA

YO

U T

TA

B:

PL

O

T D

AT

E/

TI

M

E:

U

SE

R

P (304) 624-4108

600 WHITE OAKS BLVD.

P.O. BOX 940

BRIDGEPORT, WV 26330

www.thethrashergroup.com

F (304) 624-7831

N O

BY

D

AT

E D

ES

C

R

IP

TI

O

N

THE INFORMATION CONTAINED HEREIN IS

THE SOLE PROPERTY OF THE THRASHER

GROUP, INC. REPRODUCTION OF THESE

DOCUMENTS IN WHOLE, OR IN PART FOR

ANY REASON WITHOUT PRIOR WRITTEN

PERMISSION IS STRICTLY PROHIBITED.

COPYRIGHT © 2025

THE THRASHER GROUP, INC.

W

IL

L

IA

M S

T O

W N

A A

S F

A

V

IA

T

IO

N D

R

IV

E

W

IL

L

IA

M S

T O

W N

W

V

T60-11321

6/

/2

8:

:1

AM

Au to de sk

D oc s:

//W

VA

N

G C

FM

O

B

LD

G

H

VA

C R

EN

O

/2

5.

.0

- W

VA

N G

H

VA

C R en o

- E C

R

VT

_C O

PY

.rv t

J U

N E

Au th or

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

A2.01

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

Author 06/22/26

REFLECTED CEILING

PLAN

Checker 06/22/26

W E

S T

V

IR

G

IN

IA

A

R M

Y N

A T

IO

N

A L G

U A

R D

NOTE:

1. CONTRACTOR TO REMOVE ALL EXISTING ACOUSTICAL CEILING TILE AND GRID. CONTRACTOR TO

INSTALL NEW ACOUTICAL TILE CEILING AND GRID AT SAME HEIGHT AS REMOVED CEILING.

2. CONTRACTOR TO REMOVE ALL ACOUSTIC CEILING MOUNTED LIGHTS, DETECTORS, SECURITY, FIRE ALARM, AND ALL OTHER CEILING MOUNTED ITEMS FOR REINSTALLATION. EXISTING DEVICES TO BE

REINSTALLED IN SAME LOCATION AS EXISTING.

3. CONTRACTOR TO COORDINATE WITH LOCATION OF NEW DUCTWORK AND HVAC EQUIPMENT AND

DEVICES. REFER TO MEP DRAWINGS.

Sheets
A2.01 - REFLECTED CEILING PLAN

File details come from the government source that posted it. Updated .