Addednum 2.pdf
PDF 9 MB Posted
- Solicitation number
- CRFQ 0603 ADJ2600000022 4
- Issued by
- Kanawha County, West Virginia
About this file
This is Addendum 2 to a construction contract issued by the West Virginia Department of Administration for HVAC renovations at the CFMO Building 1707. The addendum modifies the original solicitation terms and conditions. Key modifications include clarifications on project scope, technical specifications, and contractor requirements for the HVAC system upgrade and renovation work. The addendum addresses questions and concerns raised by potential bidders during the bidding process and provides additional details necessary for accurate bid preparation and submission.
The addendum establishes revised specifications, clarifications on materials and equipment standards, and updates to project requirements that contractors must incorporate into their bid proposals. It ensures all prospective bidders have consistent and complete information for developing competitive proposals. The modifications supersede conflicting language in the original solicitation documents and become part of the binding contract terms for the selected contractor upon award.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Date Printed: Jul 1, 2026 Page: 1 FORM ID: WV-PRC-CRFQ-002 2020/05
Department of Administration Purchasing Division 2019 Washington Street East Post Office Box 50130 Charleston, WV 25305-0130
State of West Virginia Centralized Request for Quote
Proc Folder: 1990727 Reason for Modification:
Doc Description: Construction: CFMO Building 1707 HVAC Renovations Addendum No. 2
Proc Type: Central Purchase Order
Date Issued Solicitation Closes Solicitation No Version
2026-07-01 2026-07-08 13:30 CRFQ 0603 ADJ2600000022 3
BID RECEIVING LOCATION
BID CLERK
DEPARTMENT OF ADMINISTRATION
PURCHASING DIVISION
2019 WASHINGTON ST E
CHARLESTON WV 25305
US
VENDOR
Vendor Customer Code:
Vendor Name :
Address :
Street :
City :
State : Country : Zip :
Principal Contact :
Vendor Contact Phone: Extension:
FOR INFORMATION CONTACT THE BUYER
David H Pauline 304-558-0067 david.h.pauline@wv.gov
Vendor Signature X FEIN# DATE
All offers subject to all terms and conditions contained in this solicitation
Date Printed: Jul 1, 2026 Page: 2 FORM ID: WV-PRC-CRFQ-002 2020/05
ADDITIONAL INFORMATION
Addendum No. 2
To respond to the Vendor Technical Questions, see attached.
To revise Specification M-1, see attachment.
To provide additional photos and drawings, see attached.
The Bid Opening Date & Time Remain July 8, 2026, at 1:30 PM EST.
No other changes.
INVOICE TO SHIP TO
ADJUTANT GENERALS
OFFICE
ADJUTANT GENERALS
OFFICE
1707 COONSKIN DR 1707 COONSKIN DR
CHARLESTON WV CHARLESTON WV
US US
Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 1 CFMO Building 1707 HVAC Renovations
Comm Code Manufacturer Specification Model #
72000000
Extended Description:
To input pricing see Exhibit "A" Bid Form
To provide Labor, materials and all associated costs to remove existing and replace with new HVAC system for the CFMO Building 1707 per the attached drawings & specifications.
SCHEDULE OF EVENTS
Line Event Event Date 1 Mandatory Prebid Meeting At 10:00 AM. EST. 2026-06-17 2 Vendor Technical Questions Due By 11:00 AM. EST. 2026-06-22
SOLICITATION NUMBER: CRFQ ADJ2600000022
Addendum Number: 2
The purpose of this addendum is to modify the solicitation identified as (“ADJ2600000022”) to reflect the change(s) identified and described below.
Applicable Addendum Category:
☐ Modify bid opening date and time.
☒ Modify specifications of product or service being sought.
☒ Attachment of vendor questions and responses.
☐ Attachment of pre-bid sign-in sheet.
☐ Correction of error.
☒ Other.
Description of Modification to Solicitation:
To respond to the Vendor Technical Questions, see attached.
To revise Specification M-1, see attachment.
To provide additional photos and drawings, see attached.
The Bid Opening Date & Time remains July 8, 2026, at 1:30 PM EST.
No other changes.
Additional Documentation: Documentation related to this Addendum (if any) has been included herewith as Attachment A and is specifically incorporated herein by reference.
Terms and Conditions:
1. All provisions of the Solicitation and other addenda not modified herein shall remain in full force and effect.
2. Vendor should acknowledge receipt of all addenda issued for this Solicitation by completing an Addendum Acknowledgment, a copy of which is included herewith. Failure to acknowledge addenda may result in bid disqualification. The addendum acknowledgement should be submitted with the bid to expedite document processing.
DEPARTMENT OF THE ARMY
JOINT FORCES HEADQUARTERS WEST VIRGINIA
1707 COONSKIN DRIVE
CHARLESTON, WEST VIRGINIA 25311-1026
July 1, 2026
ADDENDUM NO. 2- CRFQ-ADJ2600000022
RE: Construction – CFMO Building 1707 HVAC Renovation West Virginia Army National Guard Charleston, WV 25311
TO: Prospective Bidders
FROM: West Virginia Army National Guard
NOTE: This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents.
PART 1 – INFORMATION FOR BIDDERS
1. Responses to Questions
2. Answer for Question 1 and Question 1 Drawing (attached)
3. Answer for Question 3 Photo (attached)
4. Answer for Question 5 old spec & Answer for Question 5 new spec
Addendum 2 – Response for Questions
1. Please confirm ceiling work scope required to do the mechanical work - Type of tiles, specs, ceiling heights, reflected ceiling plan, etc?
a. See Answer.for.Question.7.attachment.―.Question.7.drawing.– Reflected Ceiling Plan and Specification Section 095113 – Acoustic Tile Ceiling
2. What is the existing fire alarm system?
a. Gamewell by Honeywell
3. Can you provide pictures of existing electrical service entrance to the building and existing MDP/Distribution? Is the new service a secondary service or will all existing panels be re-fed from new service.
a. See Answer.for.Question..9.Photo..attachment. The new service will be a secondary service, mainly to feed the new VAVs. New RTUs will be fed from existing electrical service.
4. Please confirm all existing hot water piping and devices are to be re-moved? Has the insulation been tested for asbestos?
a. Yes – Hot water piping to be removed. Based on the construction date of the building, asbestos is highly unlikely, however, should the contractor find suspected ACM the contractor should notify the Architect immediately
5. Do you have any old documents showing pipe routings? Most of the piping is concealed and cannot be observed.
a. See attached Answer.for.Question.❶.old.spec & Answer.for.Question.❶.
new.spec
6. Can the bid date be extended by about a week to allow for ceiling/electrical sub-contractors to visit the site?
a. The bid day has been extended to July 8th, 2026, at 1:30pm
No. 5742
COOK
WILLIAM R.
S T A T E
O F W E S T
V
I R G I N I A
A R C H I T E
C T
SHEET No.
C
AD
F
IL
E:
PROJECT No.
DRAWN:
CHECKED:
DATE:
DATE:
LA
YO
U T
TA
B:
PL
O
T D
AT
E/
TI
M
U
SE
R
P (304) 624-4108
600 WHITE OAKS BLVD.
P.O. BOX 940
BRIDGEPORT, WV 26330
www.thethrashergroup.com
F (304) 624-7831
N O
BY
D
AT
E D
ES
C
R
IP
TI
O
N
THE INFORMATION CONTAINED HEREIN IS
THE SOLE PROPERTY OF THE THRASHER
GROUP, INC. REPRODUCTION OF THESE
DOCUMENTS IN WHOLE, OR IN PART FOR
ANY REASON WITHOUT PRIOR WRITTEN
PERMISSION IS STRICTLY PROHIBITED.
COPYRIGHT © 2025
THE THRASHER GROUP, INC.
W
IL
L
IA
M S
T O
W N
A A
S F
A
V
IA
T
IO
N D
R
IV
E
W
IL
L
IA
M S
T O
W N
W
V
T60-11321
6/
/2
8:
:1
AM
Au to de sk
D oc s:
//W
VA
N
G C
FM
O
B
LD
G
H
VA
C R
EN
O
/2
5.
.0
- W
VA
N G
H
VA
C R en o
- E C
R
VT
_C O
PY
.rv t
J U
N E
Au th or
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
A2.01
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
Author 06/22/26
REFLECTED CEILING
PLAN
Checker 06/22/26
W E
S T
V
IR
G
IN
IA
A
R M
Y N
A T
IO
N
A L G
U A
R D
NOTE:
1. CONTRACTOR TO REMOVE ALL EXISTING ACOUSTICAL CEILING TILE AND GRID. CONTRACTOR TO
INSTALL NEW ACOUTICAL TILE CEILING AND GRID AT SAME HEIGHT AS REMOVED CEILING.
2. CONTRACTOR TO REMOVE ALL ACOUSTIC CEILING MOUNTED LIGHTS, DETECTORS, SECURITY, FIRE ALARM, AND ALL OTHER CEILING MOUNTED ITEMS FOR REINSTALLATION. EXISTING DEVICES TO BE
REINSTALLED IN SAME LOCATION AS EXISTING.
3. CONTRACTOR TO COORDINATE WITH LOCATION OF NEW DUCTWORK AND HVAC EQUIPMENT AND
DEVICES. REFER TO MEP DRAWINGS.
West Virginia Army National Guard ADDENDUM 1 T60-11492
CFMO Building 1707 HVAC Renovation
ACOUSTICAL PANEL CEILINGS 095113 - 1
SECTION 095113 - ACOUSTICAL PANEL CEILINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes acoustical panels and exposed suspension systems for interior ceilings.
1.2 PREINSTALLATION MEETINGS
A. Preinstallation Conference: Conduct conference at Project site
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Samples: For each exposed product and for each color and texture specified.
1.4 INFORMATIONAL SUBMITTALS
A. Coordination Drawings: Reflected ceiling plans, drawn to scale, and coordinated with each other, using input from installers of the items involved.
B. Product test reports.
C. Research reports.
D. Field quality-control reports.
1.5 CLOSEOUT SUBMITTALS
A. Maintenance data.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Surface-Burning Characteristics: Comply with ASTM E 84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.
1. Flame-Spread Index: Class A according to ASTM E 1264.
2. Smoke-Developed Index: 50 or less.
West Virginia Army National Guard ADDENDUM 1 T60-11492
ACOUSTICAL PANEL CEILINGS 095113 - 2
2.2 MINERAL FIBER ACOUSTICAL PANELS
A. Basis of Design Product:
1. Armstrong World Industries, Inc.
a. School Zone - Fine Fissured, Square Lay-in
B. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1. Armstrong World Industries, Inc.
2. CertainTeed Corporation.
3. USG Corporation.
C. Acoustical Panel Standard: Manufacturer's standard panels according to ASTM E 1264.
D. Classification: Mineral Fiber-Texture.
E. Color: White.
F. Light Reflectance (LR): 0.82.
G. Ceiling Attenuation Class (CAC): ASTM E1414.
H. Noise Reduction Coefficient (NRC): 0.70.
I. Edge/Joint Detail: Square
J. Thickness: 5/8 inch.
K. Modular Size: 24 by 24 inches.
2.3 METAL SUSPENSION SYSTEM
A. Basis of Design Product:
1. Armstrong World Industries, Inc.
a. Prelude ML 15/16” Exposed Tee System.
B. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1. Armstrong World Industries, Inc.
C. Metal Suspension-System Standard: Manufacturer's standard, direct-hung, metal suspension system and accessories according to ASTM C 635/C 635M.
West Virginia Army National Guard ADDENDUM 1 T60-11492
ACOUSTICAL PANEL CEILINGS 095113 - 3
D. Wide-Face, Double-Web, Steel Suspension System: Main and cross runners roll formed from cold-rolled steel sheet; prepainted, electrolytically zinc coated, or hot-dip galvanized, G30 coating designation; with prefinished 15/16-inch-wide flanges.
1. Structural Classification: Intermediate-duty system.
2. End Condition of Cross Runners: butt-edge type.
3. Face Design: Flat, flush.
4. Cap Material: Cold-rolled steel or aluminum.
5. Cap Finish: Painted white.
2.4 ACCESSORIES
A. Attachment Devices: Size for five times the design load indicated in ASTM C 635/C 635M, Table 1, "Direct Hung," unless otherwise indicated. Comply with seismic design requirements.
2.5 METAL EDGE MOLDINGS AND TRIM
A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:
1. Armstrong World Industries, Inc.
B. Roll-Formed, Sheet-Metal Edge Moldings and Trim: Type and profile indicated or, if not indicated, manufacturer's standard moldings for edges and penetrations that comply with seismic design requirements; formed from sheet metal of same material, finish, and color as that used for exposed flanges of suspension-system runners.
PART 3 - EXECUTION
3.1 PREPARATION
A. Measure each ceiling area and establish layout of acoustical panels to balance border widths at opposite edges of each ceiling. Avoid using less-than-half-width panels at borders unless otherwise indicated.
B. Layout openings for penetrations centered on the penetrating items.
3.2 INSTALLATION
A. Install acoustical panel ceilings according to ASTM C 636/C 636M and manufacturer's written instructions.
West Virginia Army National Guard ADDENDUM 1 T60-11492
ACOUSTICAL PANEL CEILINGS 095113 - 4
B. Install edge moldings and trim of type indicated at perimeter of acoustical ceiling area and where necessary to conceal edges of acoustical panels.
1. Do not use exposed fasteners, including pop rivets, on moldings and trim.
END OF SECTION 095113
SYMBOL LEGEND
DESCRIPTIONSYMBOL
EQUIPMENT SYMBOL - SEE LIST ON DWGS.
RIGID AIR DUCT SYSTEM
FLEXIBLE DUCT
MANUAL CONTROL DAMPER (W/LOCKING DEVICE0
CEILING SUPPLY DIFFUSER
CEILING RETURN OR EXHAUST GRILLE
DUCT SIZE INSIDE DIMENSIONS - 24"W x 10"D
DUCT SIZE - 10" DIAMETER
THERMOSTAT / SENSOR
PLAN NOTE
NEW TO EXISTING
POINT OF DEMOLITION
24”x10”
10ӯ
T S
A
DIFFUSER SYMBOL - SEE SCHEDULE
NECK SIZE
DESIGN CUBIC FEE PER MINUTE OF AIR
QUANITY FOR ROOM OR SPACE
D1 8ӯ
(2)
ABBREVIATIONS
AFF ABOVE FINISHED FLOOR
BF BELOW FLOOR
BCU BLOWER COIL UNIT
CFM CUBIC FEET PER MINUTE
COP COEFFICIENT OF PERFORMANCE
CU CONDENSING UNIT
DN DOWN
DB DRY BULB
DU DUCTLESS UNIT
EA EXHAUST AIR
EAT ENTER AIR TEMPERATURE
EC ELECTRICAL CONTRACTOR
ECH ELECTRIC CEILING HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
ESP EXTERIOR STATIC PRESSURE
EUH ELECTRIC UNIT HEATER
EWH ELECTRIC WALL HEATER
FD FIRE DAMPER
FPD FEET PER MINUTE
GC GENERAL CONTRACTOR
GUH GAS UNIT HEATER
KW KILOWATTS
HP HORSEPOWER
L LOUVER
LAT LEAVING AIR TEMPERATURE
MAU MAKE-UP AIR UNIT
MH MOUNTING HEIGHT
MBH THOUSAND BTU/HR
MOD MOTORIZED DAMPER
NIC NOT INCLUDED IN CONTRACT
NTS NOT TO SCALE
O.A. OUTSIDE AIR
PC PLUMBING CONTRACTOR
PD PRESSURE DROP
RA RETURN AIR
RH RELATIVE HUMIDITY
RPM REVOLUTIONS PER MINUTE
RTU ROOFTOP UNIT
SA SUPPLY AIR
SD SMOKE DETECTOR
SF SUPPLY FAN
STR STARTER (MOTOR)
TS TIP SPEED
TSP TOTAL STATIC PRESSURE
(TYP) TYPICAL
TZ TRANSFORMER
UNO UNLESS NOTED OTHERWISE
W/ WITH
WH WATER HEATER
WB WET BULB
W/O WITHOUT
WP WEATHER PROOF
GENERAL MECHANICAL NOTES:
1. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO
INSTALL COMPLETE AND OPERABLE HVAC SYSTEM AS INDICATED ON THE DRAWINGS,
AS SPECIFIED AND AS REQUIRED BY CODE.
2. CERTAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK, ACCESS DOORS, VOLUME
DAMPERS, ETC., ARE INDICATED FOR CLARITY IN CERTAIN AREAS. THIS DOES NOT
RELIEVE THE CONTRACTOR OF PROVIDING THESE ITEMS NOT SHOWN IN OTHER
AREAS AS REQUIRED FOR A COMPLETE INSTALLATION.
3. UNLESS NOTED OTHERWISE, LOCATE ALL ROOM THERMOSTATS 5'-0" ABOVE FINISH
FLOOR.
4. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS.
5. ALL DUCTWORK DIMENSIONS, AS SHOWN ON DRAWINGS, ARE INTERNAL CLEAR
DIMENSIONS. DUCT SIZE SHALL BE INCREASED IN SIZE TO COMPENSATE FOR
INTERNAL LININGS.
6. COORDINATE DIFFUSER, REGISTER, AND GRILLE LOCATIONS WITH ARCHITECTURAL
PLANS, LIGHTING, AND OTHER ITEMS LOCATED IN CEILING.
7. LOCATE ALL MECHANICAL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS
PANELS, CONTROLS, AND VALVING.
8. PROVIDE FLEXIBLE CONNECTIONS IN ALL DUCTWORK SYSTEMS CONNECTED TO AIR
HANDLING UNITS, FANS, AND OTHER EQUIPMENT THAT REQUIRE VIBRATION
ISOLATION. FLEXIBLE CONNECTIONS SHALL BE PROVIDED AT THE POINT OF
CONNECTION UNLESS NOTED OTHERWISE.
9. RUNS OF FLEXIBLE DUCTWORK SHALL NOT EXCEED 5 FEET.
10. ALL DUCTS SHALL BE GROUNDED ACROSS FLEXIBLE CONNECTIONS WITH FLEXIBLE
COPPER GROUNDING STRAPS.
11. TURNING VANES SHALL BE INSTALLED IN ALL RECTANGULAR DUCT ELBOWS THAT
EXCEED 45° CHANGE IN DIRECTION.
12. INSTALL 1" DUCTLINER IN FIRST 15' OF ALL RETURN AIR DUCTS.
13. SMOKE DETECTORS SHALL BE FURNISHED AND WIRED BY THE ELECTRICAL
CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL INSTALL THE SMOKE
DETECTOR IN THE DUCTWORK.
14. CONTROL RELAYS SHALL BE WIRED BY THE ELECTRICAL CONTRACTOR. THE
MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL THE RELAY IN THE
EQUIPMENT.
1. COORDINATE HVAC DEMOLITION WITH OTHER TRADES AND GENERAL CONTRACTOR.
DO NOT DEMOLISH EQUIPMENT OR COMPONENTS WITHOUT APPROVAL.
2. UNDER NO CIRCUMSTANCE SHALL DEMOLITION CAUSE DAMAGE OR REMOVAL IN
WHOLE OR IN PART OF ANY STRUCTURAL MEMBER WITHOUT EXPRESS APPROVAL OF
THE GENERAL CONTRACTOR.
3. CAP AND PROTECT ANY EXPOSED EQUIPMENT, DUCT, PIPE OR ELECTRICAL CABLE /
CONDUIT THAT RESULTS FROM DEMOLITION. UNDER NO CIRCUMSTANCE WILL
DEMOLITION RESULT IN THE PERMANENT EXPOSURE OF ANY CHARGED OR LIVE
COMPONENT OR ANY EQUIPMENT TO BE RE-USED.
4. PROTECT ANY EQUIPMENT, SYSTEM, OR COMPONENT THEREOF THAT SHALL BE RE-
USED.
5. COORDINATE DISPOSAL OF ALL REMOVED ITEMS WITH THE GENERAL CONTRACTOR.
TURN OVER ANY COMPONENTS TO THE OWNER AS DESIGNATED IN CLEAN
CONDITION, WITHOUT DAMAGE, AND WITH OPENING SEALED. FURNISH RECEIPTS OF
PROPER DISPOSAL OF ALL ITEMS REMOVED TO THE GENERAL CONTRACTOR UPON
REQUEST. RECEIPTS SHALL INDICATE DISPOSAL IN ACCORDANCE WITH ALL LOCAL,
STATE AND FEDERAL REGULATIONS.
6. ALL DUCTWORK, PIPING AND EQUIPMENT SHOWN ON THE DRAWINGS WERE BASED ON
1981 AND 2026 BID DOCUMENTS, CONTRACTOR SHALL VERIFY ALL EXISTING DUCT AND
EQUIPMENT LOCATIONS PRIOR TO BID AND SHALL ADJUST INSTALLATION F NEW WORK
ACCORDINGLY AT NO ADDITIONAL COST TO OWNER.
DEMOLITION NOTES
VAV BOX SCHEDULE
VAV1-1
NOTES:
1-4TITUS DESV 325 4.5 SCR 55 95605 208/3
VAV 1-2
VAV 1-3
VAV 1-4
435 6.0 55 95700
310 4.0 55 95640
535 7.0 55 951080
305 4.0 55 95550
190 2.5 55 95415
330 4.5 55 95420
1-4
1-4
1-4
1-4
1-4
1-4
300 4.0 55 95635 1-4
445 6.0 55 95980 1-4
215 3.0 55 95525 1-4
125 2.0 55 95350 1-4
445 5.5 55 951010 1-4
280 3.5 55 95610 1-4
145 2.0 55 95360 1-4
200 2.5 55 95465 1-4
370 5.0 55 951060 1-4
220 3.0 55 95405 1-4
220 3.0 55 95450 1-4
670 9.0 55 951120 1-4
300 4.0 55 95695 1-4
210 3.0 55 95520 1-4
1. SINGLE-DUCT VAV TERMINAL UNIT WITH ELECTRIC REHEAT COIL WITH CONTROL PANEL, SCR ELECTRIC HEAT CONTROL, DIGITAL DISPLAY
ZONE SENSOR, 208/24 VOLT AND 480/24 VOLT TRANSFORMER.
2. DISCONNECT SWITCH AND POWER FUSE.
3. FOUR POINT AVERAGING TEMPERATURE SENSOR.
4. STANDARD ACTUATOR.
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
SCR
NOTES
MARK
SIZE
CFMCFM
KW
INLET
(VAV) HEATINGCOOLING
ELECTRIC REHEAT COIL
MANUFACTURER MODEL NO.
MAX. MIN.
STEPS (°F)
EAT
(°F)
LAT
(IN)
APDMBH VOLTS/PHASE
VAV 1-5
VAV 1-6
VAV 1-7
VAV 2-1
VAV 2-2
VAV 2-3
VAV 2-4
VAV 2-5
VAV 2-6
VAV 2-7
VAV 2-8
VAV 2-9
VAV 2-10
VAV 2-11
VAV 2-12
VAV 2-13
VAV 2-14
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
6" 8.54
10" 17.08
6" 10.24
6" 8.54
10" 30.74
6" 6.83
8" 11.95
10" 20.49
6" 6.83
8" 10.24
10" 20.49
8" 13.66
8" 10.24
8" 13.66
8" 15.37
6" 8.54
8" 13.66
10" 23.90
8" 13.66
8" 20.49
8" 15.37
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
RTU-1 AAON RN-013-3-0-GAAY-V0-21-000-A 2040 4410
1.05"
0.84"
5.0 2099
138.7
172.8
108.9
149.5
77.1/63.8 53/52
53/52
195.0
270.0
158.0
218.7
208/3
208/3
1-5
76.9/62.5
97.3
76.0 100.0 11.95/14.9
RTU-3 3490 0.75" 1701 102.2 91.21 53/52 158.0 106.376.7/62.1 65 90
RTU-2 2772
1868 208/3
86.0 110.0 11.17/15.19
49.0 70.0 12.84/15.783130 360
1-5
1-5
5.0
2.0
MANUF.
SEN. L.A.T.E.A.T.
MARK
NOTES:
MODEL NO. WEIGHT H.P.E.S.P. RPM
DB/WBMBH
TOTAL
MBH DB/WB MBH INPUT
TOTAL TOTAL
MBH OUTPUT
ROOFTOP UNIT SCHEDULE
CFM SUPPLY FAN COOLING HEATING
REMARKSVOLTS/PHASEL.A.T.E.A.T. MCA MOCP
1. PACKAGED DOWNFLOW VAV ROOFTOP UNIT WITH SINGLE POINT POWER WITH NON-FUSED DISCONNECT SWITCH, DUAL COMPRESSOR, PHASE FAILURE MONITOR, 2" THICK THROW AWAY FILTERS; POWERED CONVENIENCE GFi RECEPTACLE OUTLET; 100% COMPARATIVE ENTHALPY CONTROL ECONOMIZER WITH BAROMETRIC RELIEF DAMPER; EXHAUST FANS; HAIL GUARDS; MICROPROCESSOR CONTROLLER; BUILT IN DISCONNECT.
2. PROVIDE WITH FACTORY INSTALLED SENSORS FOR COIL LEAVING TEMP, DUCT HIGH LIMIT SWITCH, RETURN AIR TEMP, LEAVING AIR TEMP, RETURN AIR ENTHALPY, OUTSIDE AIR ENTHALPY, DIRTY FILTER, AND SUPPLY FAN AIR
PROVING.
3. PROVIDE CURB ADAPTOR.
4. PROVIDE WITH MODULATING GAS HEAT.
EER/IEERSUPPLY
AIR CFM
RETURN
AIR CFM
OUTSIDE
AIR CFM (MIN) QTY
AAON
AAON
RN-016-3-0-GAAY-V0-21-000-A
RN-011-3-0-GAAY-V0-21-000-A
5. PROVIDE RETURN AIR DUCT SMOKE DETECTOR.
MODEL NO.
NOTES:
MARK
EUH-1
KW BTU VOLTS / PHASE NOTESMANUFACTURER WEIGHT
(LBS)
QMARK MUH05-81 27 5.0 208/3 117.0
1. FAN-FORCED UNIT WALL HEATER WITH BUILT-IN THERMOSTAT; THERMAL OVERLOAD
PROTECTION; FAN DELAY SWITCH; POWER; MOUNTING BRACKETS.
EUH-2,3,4,5 QMARK MUH-10-8 38 10.0 208/3 134.1
EUH-6,7 QMARK MUH-15-8 53 15.0 208/3 151.2
ELECTRIC HEATER SCHEDULE
DESCRIPTIONUSEMODEL
NO.MANUFACTURERMARK NOTES
A. SIZE OF NECK FOR ABOVE ARE SHOWN ON PLAN.
B. SIZE OF GRILLE FOR ABOVE ARE SHOWN ON PLAN.
GENERAL NOTES:
1. STEEL
2. ALUMINUM
3. WHITE FINISH
NOTES:
D1
R1
R2
TITUS TMS
PAR
25RL
SUPPLY
RETURN
RETURN
SQUARE FULL LOUVER FACE CEILING DIFFUSER WITH FRAME
TYPE-3 FOR LAY-IN.
24"x24" SQUARE FLUSH PERFORATED FACE CEILING
DIFFUSER WITH FRAME TYPE-3 FOR LAY-IN.
1,3
2,3
2,3
TITUS
TITUS
D2 TITUS S300FS SUPPLY INDIVIDUALLY ADJUSTABLE BLADES DOUBLE DEFLECTION
GRILLE, WITH EXTRACTOR SET AT 45° ANGLE.
2,3
D3 TITUS 301RL SUPPLY ADJUSTABLE BLADES SUPPLY GRILLES WITH FRAME TYPE-1
FOR SURFACE MOUNT.
2,3
ADJUSTABLE BLADES RETURN GRILLES WITH FRAME TYPE-1
FOR SURFACE MOUNT.
GRILLE, REGISTER AND DIFFUSER SCHEDULE
GAS LOAD SCHEDULE
SIZING IN ACCORDANCE WITH INTERNATIONAL FUEL CODE 2018,
TABLE 402.4 (2) SCHEDULE 40 METALLIC PIPE AT 7" WC AND 300'
TOTAL DEVELOPED LENGTH. VERIFY PRESSURES AND EQUIPMENT
BTUS, ADJUST SIZES ACCORDINGLY.
RTU-1
RTU-2
RTU-3 195
IDENTIFICATION GAS LOAD (MBH)
TOTAL CONNECTION 660
SHEET No.
C
AD
F
IL
PROJECT No.
DRAWN:
CHECKED:
DATE:
DATE:
LA
YO
U T
TA
B:
PL
O
T D
AT
E/
TI
M
U
SE
R
P (304) 624-4108
600 WHITE OAKS BLVD.
P.O. BOX 940
BRIDGEPORT, WV 26330
www.thethrashergroup.com
F (304) 624-7831
N O
BY
D
AT
E D
ES
C
R
IP
TI
O
N
THE INFORMATION CONTAINED HEREIN IS
THE SOLE PROPERTY OF THE THRASHER
GROUP, INC. REPRODUCTION OF THESE
DOCUMENTS IN WHOLE, OR IN PART FOR
ANY REASON WITHOUT PRIOR WRITTEN
PERMISSION IS STRICTLY PROHIBITED.
COPYRIGHT © 2024
THE THRASHER GROUP, INC.
6/
/2
8:
:2
AM
Au to de sk
D oc s:
//W
VA
N
G C
FM
O
B
LD
G
H
VA
C R
EN
O
/W
VA
N G
_M
EP
_R
.rv t
JU
N
E
TT
G
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
M1.01
LE
G
EN
D
, N O
TE
S
SC
H
ED
U
LE
S
TTG 07/15/2025
T60-11492
W
VA
N G
C
FM
O B
LD
G
H
VA
C
R
EN
O
VA
TI
O
N
C H
AR
LE
ST
O
N , W
ES
T
VI
R
G
IN
IA
LEGEND, NOTES &
SCHEDULES
KES 07/15/2025
W
ES
T
VI
R G
IN
IA
A R
M Y
N
AT
IO
N
AL
G
U
AR
D
TT
G
/2 6/
AD
D
EN
D
U M
N O
.1
ADDENDUM ACKNOWLEDGEMENT FORM
SOLICITATION NO.: CRFQ ADJ2600000022
Instructions: Please acknowledge receipt of all addenda issued with this solicitation by completing this addendum acknowledgment form. Check the box next to each addendum received and sign below.
Failure to acknowledge addenda may result in bid disqualification.
Acknowledgment: I hereby acknowledge receipt of the following addenda and have made the necessary revisions to my proposal, plans and/or specification, etc.
Addendum Numbers Received:
(Check the box next to each addendum received)
☒ Addendum No. 1 ☐ Addendum No. 6
☒ Addendum No. 2 ☐ Addendum No. 7
☐ Addendum No. 3 ☐ Addendum No. 8
☐ Addendum No. 4 ☐ Addendum No. 9
☐ Addendum No. 5 ☐ Addendum No. 10
I understand that failure to confirm the receipt of addenda may be cause for rejection of this bid. I further understand that that any verbal representation made or assumed to be made during any oral discussion held between Vendor’s representatives and any state personnel is not binding. Only the information issued in writing and added to the specifications by an official addendum is binding.
Company
Authorized Signature
Date
NOTE: This addendum acknowledgement should be submitted with the bid to expedite document processing.
| 1 |
| 1 |
| 2 |
| Question 1 Drawing.pdf |
| Sheets |
| A2.01 - REFLECTED CEILING PLAN |
| Answer for Question 5 M-1 - Old Spec.pdf |
| SAB old bldg001 |
| SAB old bldg002 |
| SAB old bldg003 |
| SAB old bldg004 |
| SAB old bldg005 |
| SAB old bldg006 |
| SAB old bldg007 |
| SAB old bldg008 |
| SAB old bldg009 |
| SAB old bldg010 |
| SAB old bldg011 |
| Answer for Question 5 M-1 - Old Spec.pdf |
| SAB old bldg001 |
| SAB old bldg002 |
| SAB old bldg003 |
| SAB old bldg004 |
| SAB old bldg005 |
| SAB old bldg006 |
| SAB old bldg007 |
| SAB old bldg008 |
| SAB old bldg009 |
| SAB old bldg010 |
| SAB old bldg011 |
| Answer for Question 5 M-1 New spec.pdf |
| Sheets |
| M1.01 - LEGEND, NOTES & SCHEDULES |
File details come from the government source that posted it. Updated .