QCC 202609800 SAFS.pdf
PDF 157 KB Posted
- Attached to
- AD Project #202609800 Quinsigamond Community College, Auburn, Boylston, Grafton, Holden, etc.
- Solicitation number
- BD-27-1019-DCP06-OOL01-132045
- Issued by
- Massachusetts
About this file
This is a Space Allocation and Finish Schedule document for Quinsigamond Community College, a Massachusetts institution located in Auburn, Boylston, Grafton, Holden, Leicester, Millbury, Paxton, Shrewsbury, West Boylston, or Worcester. The document outlines the departmental space requirements for Project Number 202609800, requesting approximately 5,600 usable square feet of facility space. The space allocation includes staff areas comprising 438 square feet with 4 staff members and 2 seats; instructional spaces totaling 4,125 square feet including a 2,500-square-foot lab space, a 750-square-foot classroom, a 250-square-foot tool cage, and a 300-square-foot equipment storage area; entry and support areas of 563 square feet encompassing restrooms, an MDF room, and waiting/seating areas; and a 500-square-foot secured outdoor training space with fenced area and concrete pads. The related state and local contract opportunity indicates the request is for a ten-year term, with DCAMM willing to consider space ranging from 4,000 to 7,000 usable square feet.
The Space Allocation and Finish Schedule specifies detailed specifications for each space type, including flooring materials (concrete, ceramic tile, resilient tile flooring, and carpet), partition types, and specialized features such as emergency eyewash stations, gas connections with automatic shut-off, exhaust ventilation, electrical service panels with multiple circuits, audio-visual equipment blocking, and exterior lighting for the outdoor training area. The document does not address pricing terms, set-asides, incumbent information, or funding sources within its scope, as it functions as a technical specification document detailing spatial requirements and finishes rather than procurement or financial terms.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| QCC 202609800 SNDA.pdf | ||
| QCC 202609800 RFP.pdf | ||
| QCC 202609800 RNDA.pdf | ||
| QCC 202609800 Office Lease.pdf | ||
| QCC 202609800 Estoppel Certificate.pdf | ||
| QCC 202609800 Ten-Year Lease Proposal Form.docx | DOCX document | |
| QCC 202609800 Warning.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Quinsigamond Community College
Auburn, Boylston, Grafton, Holden, Leicester, Millbury, Paxton, Shrewsbury, West Boylston or Worcester
Project Number 202609800
SECTION B-3
SPACE ALLOCATION AND FINISH SCHEDULE
A TOTAL OF APPROXIMATELY 5,600 USABLE SQUARE FEET
July 2026
B-3. SPACE ALLOCATION AND FINISH SCHEDULE
Project Number 202609800
July 2026
SUMMARY OF SPACE ALLOCATION
Staff Count Seat Count Usable Area
Staff Areas 4 2 438
Instructional Spaces 0 0 4,125
Entry & Support 0 1 563 5,125
SUBTOTAL:
Outdoor Training Space 0 0 500
TOTAL: 4 3 5,625
Quinsigamond Community College
TOTAL PARTI- FLOOR NOTATIONS ON
STAFF SEATS SF SUBTOTAL UNITS SF SUBTOTAL SF TIONS COVER SPECIFICATIONS (cf. RFP section B-2)
STAFF AREAS
Professor Offices 2 1 200 200 200 Full, UA-Wkstn CPT Lock,sidelight,4-V/D/P Adjunct Offices (Hoteling Office) 2 1 150 150 150 Full, UA-Wkstn CPT Lock, sidelight, 4-V/D/P
Subtotal Staff Areas 4 2 350 350
List of Abbreviations Subtotal 4 2 350 0 350 SF Usable Square Feet Circulation 25% 88 Full Office or room with full height partitions and door
TOTAL USABLE AREA 438 UA-Wkstn Open area with user agency-installed systems furniture LL-Wkstn Open area with landlord-installed systems furniture Open Open area with no partitions CPT Carpet RTF Resilient Tile Flooring V/D/P Combination Voice, Data, Power Outlet AV Audio-Visual SDT Static Dissipative Tile CER Non-Skid Ceramic Tile Flooring Conc Concrete
Staff Areas
TYPE OF ROOM OR AREA
B-3. SPACE ALLOCATION AND FINISH SCHEDULE: Quinsigamond Community College Auburn, Boylston, Grafton, Holden, Leicester, Millbury, Paxton, Shrewsbury, West Boylston or Worcester
PERSONNEL SPACE SUPPORT SPACE
STAFF SF SUBTOTAL UNITS SF SUBTOTAL SF TIONS COVER SPECIFICATIONS (cf. RFP section B-2)
SUPPORT AREAS
Lab Space 1 2,500 2,500 2,500 Full CONC Lock,sidelight,V/D/P to User Agency supplied lecturn ,gas connections with automatic emergency shut-off, exhaust ventilation, 600 amp service panel with 12-208v/120v circuits, emergency eye wash station, floor core
Tool Cage 1 250 250 250 Cage CONC Lock, floor to ceiling chain link fencing with 3 'entry gate, Classroom 1 750 750 750 Full CONC Lock, sidelight, V/D/P to User Agency supplied lecturn,wall and ceiling blocking for User Agency AV equipment, floor core Equipment Storage 1 300 300 300 Full CONC Lock, sidelight, 4-duplex outlets
Subtotal Support Areas 3,800 3,800 List of Abbreviations Subtotal 3,800 3,800 SF Usable Square Feet Circulation 25% 325 Full Office or room with full height partitions and door
TOTAL USABLE AREA 4,125 UA-Wkstn Open area with user agency-installed systems furniture LL-Wkstn Open area with landlord-installed systems furniture Open Open area with no partitions CPT Carpet RTF Resilient Tile Flooring V/D/P Combination Voice, Data, Power Outlet AV Audio-Visual SDT Static Dissipative Tile CER Non-Skid Ceramic Tile Flooring Conc Concrete
Instructional Spaces
TYPE OF ROOM OR AREA
B-3. SPACE ALLOCATION AND FINISH SCHEDULE: Quinsigamond Community College Auburn, Boylston, Grafton, Holden, Leicester, Millbury, Paxton, Shrewsbury, West Boylston or Worcester
Project Number 202609800
PERSONNEL SPACE SUPPORT SPACE
STAFF SEAT SF SUBTOTAL UNITS SF SUBTOTAL SF TIONS COVER SPECIFICATIONS (cf. RFP section B-2)
Support Single Use Restrooms 3 60 180 180 Full CER Lock, deadbolt with in-use indicator MDF 1 120 120 120 Full RTF Lock, sidelight, HVAC, automatic exhaust
Subtotal Meeting Areas 300 300
ENTRY AREAS
Waiting/Seating 0 1 150 150 150 Full, UA-Wkstn CPT Door bell
Subtotal Entry Areas 0 1 150 150 List of Abbreviations Subtotal 0 1 150 300 450 SF Usable Square Feet Circulation 25% 113 Full Office or room with full height partitions and door
TOTAL USABLE AREA 563 UA-Wkstn Open area with user agency-installed systems furniture LL-Wkstn Open area with landlord-installed systems furniture Open Open area with no partitions CPT Carpet RTF Resilient Tile Flooring V/D/P Combination Voice, Data, Power Outlet AV Audio-Visual SDT Static Dissipative Tile CER Non-Skid Ceramic Tile Flooring Conc Concrete
TYPE OF ROOM OR AREA
Entry & Support
PERSONNEL SPACE SUPPORT SPACE
B-3. SPACE ALLOCATION AND FINISH SCHEDULE: Quinsigamond Community College Auburn, Boylston, Grafton, Holden, Leicester, Millbury, Paxton, Shrewsbury, West Boylston or Worcester
STAFF SEAT SF SUBTOTAL UNITS SF SUBTOTAL SF TIONS COVER SPECIFICATIONS (cf. RFP section B-2)
Outdoor Training Space Secure Fenced Area 1 500 500 500 Fence Conc 6'-00" high fencing with 2-3'-00", double gate, 4-6x6 concrete pads for U/A supplied equipment, 4- 208v disconnects, exterior lighting.
Subtotal Outdoor Storage 500 500
List of Abbreviations Subtotal 0 0 0 500 500 SF Usable Square Feet
0 Full Office or room with full height partitions and door TOTAL USABLE AREA 500 UA-Wkstn Open area with user agency-installed systems furniture
LL-Wkstn Open area with landlord-installed systems furniture Open Open area with no partitions CPT Carpet RTF Resilient Tile Flooring V/D/P Combination Voice, Data, Power Outlet AV Audio-Visual SDT Static Dissipative Tile CER Non-Skid Ceramic Tile Flooring Conc Concrete
TYPE OF ROOM OR AREA
OUTDOOR TRAINING SPACE
PERSONNEL SPACE SUPPORT SPACE
B-3. SPACE ALLOCATION AND FINISH SCHEDULE: Quinsigamond Community College Auburn, Boylston, Grafton, Holden, Leicester, Millbury, Paxton, Shrewsbury, West Boylston or Worcester
| Cover |
| Summary |
| Staff |
| Instructional Spaces |
| Entry & Support |
| Outdoor Storage |
File details come from the government source that posted it. Updated .