This document is a Quality Assurance Provisions (QAP) for shipping containers and wooden skids, specifically for cannon containers at the Watervliet Arsenal. The document outlines detailed quality control requirements for manufacturing 16 containers for 155-MM Howitzer M284 tubes, with strict inspection criteria covering moisture content, material defects, workmanship, dimensional requirements, strapping, and marking.

Key technical specifications include first article inspection requirements, with a 15-calendar day advance notification for government representative inspection. The containers must meet ASTM D6199 standards for wood quality, have plywood covers with the best surface facing outward, uniform strapping, and precise workmanship standards such as flush end cleats, no exposed splinters, and properly driven nails and screws. The solicitation (W911PT-25Q0047) is issued by the Department of the Army Materiel Command Contracting Command Detroit Arsenal, with delivery required FOB destination and a first article testing requirement.

View the file

Other files

File Type Posted
11580190-4.pdf PDF
25Q0047.pdf PDF
CN3.pdf PDF
11579763 REV AA.pdf PDF
11580190-3.pdf PDF
010301-QAP-APPX-WVA.docx DOCX document
E -5051018Y - 11580190.docx DOCX document
11580190-1.pdf PDF
010731-QAP-APPX-BL.docx DOCX document
11580190-2.pdf PDF
CN 12.pdf PDF
A -5051018Y - 11580190.docx DOCX document
CN 5.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

QUALITY ASSURANCE PROVISIONS

FOR: SHIPPING CONTAINER AND SKIDS (WOOD)

END ITEM: ALL CANNONS

PART I - LIST OF APPLICABLE DOCUMENTS

NUMBER NOMENCLATURE

QAP-APPENDIX-WVAGENERAL QUALITY ASSURANCE PROVISIONS
PACKAGING DATA SHEETSAS SPECIFIED IN PROCUREMENT DOCUMENTS
BILL OF MATERIALSAS SPECIFIED IN APPLICABLE PDS OR DRAWINGS
SPECIFICATIONSAS SPECIFIED IN APPLICABLE PDS OR DRAWINGS
ASTM D6199QUALITY OF WOOD MEMBERS FOR CONTAINERS AND PALLETS

PART II QUALITY PROVISIONS

1. DISTRIBUTION STATEMEMT A: UNLIMITED.

2. The Contractor Requirements and Inspection Provisions contained in QAP-APPENDIX-WVA form a part of this QAP.

3. Quality Conformance Inspection shall consist of inspection of all Contract Quality Requirements in accordance with QAP-APPENDIX-WVA and this QAP.

4. FIRST ARTICLE REQUIREMENTS. Unless otherwise specified in the contract, a First Article Inspection shall be conducted in accordance with QAP-APPENDIX-WVA and STM-1.

PART III INSPECTION REQUIREMENTS

NOTE: ALL MEMBERS CUT FOR ONE TYPE AND ORDER OF CONTAINER SHALL BE CONSIDERED A LOT.

MAJOR CHARACTERISTICS SAMPLE SIZE PER LOT INSPECTION METHOD

101 MOISTURE CONTENT & MATERIAL DEFECTS 5 STM-2

102 WORKMANSHIP 5 STM-3

103 DIMENSIONAL REQUIREMENTS 5 SCALE

104 APPLICATION OF STRAPPING 5 VISUAL

105 MARKING 5 VISUAL

PART IV CERTIFICATIONS

NUMBER CHARACTERISTICS

301MATERIAL:
IAW APPLICABLE PDS, SPECIFICATION, BILL OF MATERIALS OR DRAWINGS
AS SPECIFIED IN PROCUREMENT DOCUMENTS

REVISION STATUS

ARDEC - QUALITY ENGINEERING DIRECTORATE -

ERR

DATE

REV

DWG DATE

REV

BENET LABORATORIES SUPPORT, WATERVLIET, NY 12189-4000

59260

950215

P

PREPARED BY CAGE CODE 1NUW7

DWG CAGE CODE 19206

L3Q1007

030211

R

SUBMITTED BY R. HUYCK

QAP/DWG 167917

APPROVED BY M. LONGMATE

SHEET 1 OF 2

AMSTA-AR-QAC-T Form 317-E, 1 Mar 00 Edition of SIOWV Form 317-E, 1 Jul 97 is obsolete.

PART V TEST METHODS AND PROCEDURES

STM-1 FIRST ARTICLE REQUIREMENTS

A government representative will inspect the initial container. A 15-calendar day prior notification is required to permit a representative to attend the inspection. Upon approval of the container inspection, the contractor will retain and will use this same container as a visual reference for constructional details. This container may be eventually used as part of the production lot.

STM-2 MOISTURE CONTENT & MATERIAL DEFECTS

Moisture content and material defects shall be determined in accordance with ASTM D6199.

STM-3 WORKMANSHIP

Workmanship shall be in accordance with good commercial practice for this type of work. Containers shall be free from exposed splinters, sharp projections, and ragged edges. End cleats shall be flush with sides. Plywood covers shall have the best surface to the outside. Strapping shall be uniformly applied, conforming to container surfaces and firmly secured in place. Nails shall not be bent or overdriven. When screws are specified they shall be hammer driven only far enough to make threads take hold, then driven the remaining distance with a manual or power screwdriver, avoiding overdriving. All screws shall be so driven that their heads shall not protrude above the surface of the board. For some cases it may be necessary to countersink.

ERR

DATE

REV

DWG DATE

REV

CAGE CODE

QAP/DWG

SHEET

L3Q1007

030211

R

19206

167917

AMSTA-AR-QAC-T Form 317-E,(CONT) 1 Mar 00 Edition of SIOWV Form 317-E, 1 Jul 97 is obsolete.

File details come from the government source that posted it. Updated .