QAIRQMT_REPORT 4767FD.pdf

PDF 87 KB Posted

Attached to
Repair Services for the MUTES Program
Solicitation number
FA825026Q0011
Issued by

About this file

This is a Quality Assurance Provisions and Special Inspection Requirements form (AFMC Form 807) for the repair of an Azimuth Drive Motor (Part Number DPM56PF4-K7714, National Stock Number 6105013294767FD). The form specifies that standard inspection per FAR 52.246-2 will be conducted at the contractor's facility (source inspection and acceptance) as the item must meet critical technical and performance requirements. Inspection at destination is not feasible because the RTS-SPO lacks proper test equipment and reopening the item's packaging would necessitate costly repacking with no added value.

The technical authority, Jason L. Francom (415 SCMS/GUMAA, 801-586-2174), determined on 01 JUL 2024 that the item qualifies for source-point inspection and acceptance under all three applicable criteria. A previous source will be used for this acquisition, and no pre-award quality survey is required. The form includes a statement confirming that the requirement does not necessitate the use of Class I ozone-depleting substances. The item manager is Christina McGinnis (801-895-1226), and the equipment specification contact is Jason L. Francom (801-586-2884). Quality provisions cannot be downgraded without technical authority coordination, and the technical authority must be notified if award selection is made to a new source.

View the file

Other files

File Type Posted
FA825026Q0011.pdf PDF
ITMDESC_REPORT 6234FD.pdf PDF
ITMDESC_REPORT 4767FD.pdf PDF
TRNSPDATA_REPORT.pdf PDF
PKGRQMT_REPORT.pdf PDF
PWS.pdf PDF
QAIRQMT_REPORT 6234FD.pdf PDF
4767FD IUID.pdf PDF
CDRLS.pdf PDF
CAVAF.pdf PDF
PACKAGING SOW.pdf PDF
6234FD IUID.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RECOMMENDED QUALITY ASSURANCE PROVISIONS

AND SPECIAL INSPECTION REQUIREMENTS

1. PR / MIPR NUMBER

2. NATIONAL STOCK NUMBER

6105013294767FD

3. POINT OF INSPECTION

SOURCE DESTINATION

X

SEE DFARS 246.402

4. POINT OF ACCEPTANCE

SOURCE DESTINATION

X

5. ITEM MANAGER / PHONE

Christina, Mcginnis / 801-895-1226

6. EQUIPMENT SPEC / PHONE

Francom, Jason L / 801-586-2884

7. CONTRACT QUALITY REQUIREMENTS/SPECIAL INSPECTION REQUIREMENTS

CERTIFICATE OF CONFORMANCE

FAR 52.246-15

CONTRACT RESPONSIBILITY FOR INSPECTION

FAR 52.246-15

X STANDARD INSPECTION

FAR 52.246-2,-3,-4,-5 OR -6 AS APPLICABLE TO CONTRACT

HIGHER LEVEL CONTRACT QUALITY REQUIREMENTS FAR 52.246-11

COMMERCIAL ITEM INSPECTION

FAR 52.212-4

OTHER (Describe in Block 8)

8. REMARKS

Grimes, Willie MNAME: 11 OCT 2012DATE:

P/N: DPM56PF4-K7714; Nomenclature: Azimuth Drive Motor T.O. 31R2-4-950-4 ESD: No SPI: Yes, F000003XE4

"In accordance with FAR 46.2 Contract Quality Requirements, it has been determined by the Technical Authority that the item to be repaired under this acquisition must meet critical technical/performance requirements and therefore inspection at the contractor's facility, per FAR 52.246-2 Standard Inspection, is necessary."

Block 3. This item meets all three criteria for inspection at Source.

Block 4. This item meets the criteria for acceptance at the Source.

Note: It is not feasible to inspect/accept these items at the destination. The RTS-SPO does not have the proper test equipment at this location, if the packaging of this item is disturbed, opened in any way, these item will have to be re-packed. Not cost effective, No Value Added.

8a. OZONE DEPLETING SUBSTANCES (ODS)

X STATEMENT

"I HAVE REVIEWED THE REQUIREMENT, INCLUDING AVAILABLE TECHNICAL DOCUMENTATION, AND BELIEVE THAT IT DOES NOT REQUIRE THE CONTRACTOR USE CLASS I OZONE DEPLETING SUBSTANCES (ODS) IDENTIFIED IN AIR FORCE POLICY, NOR IS IT WRITTEN SO THAT IT CAN

ONLY BE MET BY THE USE OF A CLASS I ODS."

WAIVER (SEE DAFFARS 5323.8)

NOTE: Quality provisions as annotated hereon will not be downgraded without Technical Authority coordination. The Technical Authority must be notified if award selection is made to a new source using Acquisition Method Code (AMC) 3, 4, or 5.

9. QUALITY PRE-AWARD SURVEY

YES NEW SOURCE

X PREVIOUS SOURCEX NO

AFMC PARTICIPATION

RECOMMENDED

10. CODES

A. I&A

B. CQR

C

11. SIGNATURE OF TECHNICAL AUTHORITY

Francom, Jason L

ORGANIZATION / SYMBOL

415 SCMS / GUMAA

PHONE

801-586-2174 / 586-2174

DATE

01 JUL 2024

Page 1 of 1Prescribed by: AFMCI20-102 Version 4Generated by PRPS using Jasper Reports on 08 May 2026

AFMC FORM 807, 20230130 PREVIOUS EDITION IS OBSOLETE