The document QA Mobile medical shelter~1.docx is a procurement file from the Illinois Department of Public Health (IDPH) soliciting five rapidly deployable mobile medical shelter systems through a competitive bidding process. The solicitation (number 25-482DPH-PREPD-B-47752) requires a comprehensive shelter system including five mobile shelter units, five kitchenette buildings, five restroom buildings, two mobilization trailers, and associated equipment. The shelters must be configurable for emergency preparedness, capable of housing up to three quarantined individuals, and adaptable as mobile clinics or offices during public health emergencies. Electronic bids are due by May 30, 2025, and must remain valid for 180 days. The contract will have an initial twelve-month term with a maximum total contract duration of ten years, with all items required to be delivered within 90 days of contract signing.

The procurement emphasizes specific technical requirements including rapid setup within 15 minutes without tools, negative air pressure filtration, HVAC systems capable of surgical-level disinfection, and ADA compliance. The state has established a 1% Business Enterprise Program (BEP) goal for businesses owned by minorities, women, and persons with disabilities, with potential vendor tax credits for hiring qualified veterans or ex-offenders. Subcontracting is limited to 49% for non-small businesses, and there is a preference for domestically manufactured products. Funding will come from the IDPH budget, potentially involving partial or full federal funding. The state reserves the right to award the contract to the lowest-priced, responsive, and responsible bidder, with vendors required to complete comprehensive disclosure forms and demonstrate compliance with state procurement regulations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Question and Answers Illinois Department of Public health

25-482DPH-PREPD-B-47752

Q: Mobile Collapsible 3-Room Building Specifications

1.The mobile shelter must be a collapsible building that can be fully set up and functioning without tools with three personnel in around fifteen (15) minutes.
2.The mobile collapsible building must be designed to be set up without electricity (non-motorized).
3.Each building must have three (3) rooms consisting of the following square footage (listed on line 4 and not exceed an exterior length of 19'9" long while in its stored configuration. When not in use, the building must not exceed 45" wide.
4.Each of the three rooms on each shelter must be at least 60 square feet and not exceed 129 square feet.
5.The shelter must have sidewalls that must be capable of opening and closing after the deployable building is erected; in addition, the sidewalls must be able to bring in equipment larger than the width of the door opening and has built-in handles to assist in opening and closing for use in a potential emergency.

From the above, is this structure truly collapsable to where when being transported it is in a sense “folded up”? Then when onsite it is “unfolded” and put into place?

A: Yes the unit would have to fold to be transported and expanded when in place.

Do you have a drawing or idea of what this is to resemble?

A:

this diagram is for description purpose only. This is not the specs included in the IFB. For specification requirements, please refer to Section 1.2. of the IFB document.