PWS Simulator Radar Test Equipment_Solicitation.pdf
PDF 245 KB Posted
- Attached to
- KC-46 Radar Calibration Federal contract opportunity
- Solicitation number
- FA4484-25-Q0042
About this file
This Performance Work Statement (PWS) outlines calibration requirements for Simulator Radar Test Equipment (RWR Tester) for the 605th Aircraft Maintenance Squadron at Joint Base McGuire-Dix-Lakehurst. The contract covers calibration of five Model 527 radar test equipment units (serial numbers 00119, 00097, 00109, 00101, 00115) with NSN 6940-01-563-1116 and Part Number 39300-40002-10, supporting KC-46 Pegasus air refueling aircraft mission readiness. The calibration shall be performed in accordance with technical order TO 1KC46-A-99-51-0000-05A0A-345A-A, with contractors required to use certified test equipment, provide detailed documentation, and verify component tolerances.
The contract is funded annually and spans five fiscal years from FY25 to FY29 (30 September 2025 - 29 September 2030), with calibration services to be completed within 3 calendar days per system. Key contractor responsibilities include performing detailed calibration, conducting preventive maintenance, running diagnostics, and submitting monthly performance reports and calibration certifications. The government will evaluate contractor performance using a Quality Assurance Surveillance Plan (QASP), with performance standards including 100% technical compliance, 95% on-schedule completion, and 100% documentation submission rate. Notably, the contractor will not be on-base, and there are no specific security or base entry requirements for this contract.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| JB MDL Antiterrorism Awareness for Contractors Trifold 22APR 24.pdf | ||
| JB MDL AT Awareness Guide for Contractors 22APR24.pdf | ||
| Combined Synopsis -Solicitation_KC 46 Radar Calibration.pdf | ||
| Wage Determination.pdf | ||
| SFS Appendix - CONTRACTOR APPENDIX 20 Sep 23.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Performance Work Statement (PWS)
Simulator Radar Test Equipment Calibration (RWR Tester) 605th Aircraft Maintenance Squadron 1835 East Arnold Ave, JB MDL, NJ 08641
Mission/Background Statement:
The new KC-46 Pegasus air refueling aircraft operates two of America's largest strategic aerial ports supporting the delivery of cargo and personnel to combatant commanders abroad.
Mission:
Warfighters Projecting Power Through Global Reach and Agile Maneuver
Priorities:
• Resilient Airmen & Families
• Relentless Innovation
• Mission Ready Tonight
1. Description of Services This Performance Work Statement (PWS) outlines the requirement for calibration of Simulator Radar Test Equipment, NSN: 6940-01-563-1116, Part Number: 39300-40002-10.
Calibration shall be performed IAW TO 1KC46-A-99-51-0000-05A0A-345A-A to maintain KC-46 sustainment and mission readiness.
This contract ensures continued fleet health through proper calibration and usage of radar simulator test equipment. The equipment shall be maintained by Air Force personnel and used solely under Air Force technical data guidance in support of fleet troubleshooting.
The contractor shall calibrate the items and provide a due date upon which calibration will be completed.
2. Current Technical Equipment
MFR # Description Serial #
39300-40002-10 Simulator Radar Test Equipment (527 RWR Tester)
00119
39300-40002-10 Simulator Radar Test Equipment (527 RWR Tester)
00097
39300-40002-10 Simulator Radar Test Equipment (527 RWR Tester)
00109
39300-40002-10 Simulator Radar Test Equipment (527 RWR Tester)
00101
39300-40002-10 Simulator Radar Test Equipment (527 RWR Tester)
00115
2.1. 500 MHz – 18 GHz Receiver
• RF Frequency
• Frequency Range (Carrier): 500 MHz to 18 GHz
• Frequency Accuracy (Absolute)
• ± 0.001% for a single frequency emitter
• ± 5 MHz for multiple emitters or multiple frequency, single emitters
• Frequency Resolution: > 500 kHz
• Frequency Switching Time:
• < 200 usec single frequency/emitters
• < 1 usec multiple frequency/emitters
• Spurious/Harmonics 2.1.1.5.1. Spurs: < -50 dBc
• 2.1.1.5.2.Harmonics: < -10 dBc
• Phase Noise
• -55 dBc at 10 kHz offset for a 10 GHz carrier for a single frequency emitter, single emitter.
• Intrapulse Modulation
• Frequency Modulation
• Deviation/Rate: ± 50 MHz / 20 usec
• Accuracy: ± 5 MHz
• Resolution: 500 kHz
• Phase Modulation (Bi-Phase) 2.1.2.2.1. Chip Width: 100 nsec Min.
• Number of Chips: Up to 32 chips
• Pulse Modulation
• Pulse Repetition Interval;
• PRI Range: 1 usec Min.
• PRI Accuracy: ± (15 nsec + 10 ppm of programmed PRI)
• PRI Resolution: 50 nsec
• PRI Jitter/Stagger: Greater than or equal to 1% and up to 99% change of either the PW or PRI (average pulse interval can be either PW or PRI).
• Pulse Width 2.1.3.2.1. PW Range: 50 nsec Min.; CW
• PW Accuracy: ± (25 nsec + 10 ppm of programmed PW)
• PW Resolution: 50 nsec
• Pulse Width Rise/Fall Time: > 15 nsec / 15 nsec
• On/Off Ratio: 60 dB
• Types: CW, Pulse, Agile, Jitter, Random, Doublet, Triplet, User Defined
• Amplitude Modulation
• Amplitude Range: 45 dB
• Accuracy (relative): The great of ± 2 dB or ± 10% of programmed value, with 5 dB min background attenuation.
• Resolution: 0.5 dB minimum
• Settling Time: < 1 usec
• Modulation Rate: 0.005 Hz – 2 kHz
• Accuracy: 0.005 Hz, ± 0.02%
• Resolution: 0.005 Hz
• Scan Modulation Types: Conical, raster, helical, sector, dwell, height finder, circular, palmer modifier, orthogonal, Loro, spiral.
• Power Levels
• Min-Max Power Level: -70 dBm to +20 dBm
2.2. Receiver for Optional MMW1 Band
• Frequency Range (Carrier): 28 GHz to 40 GHz
• Frequency Accuracy (Absolute) 2.2.1.2.1. ± 0.002% for a single frequency emitter
• ± 20 MHz for multiple emitters or multiple frequencies, single emitters
• Frequency Resolution: > 500 kHz
• Frequency Switching Time: 2.2.1.4.1. < 200 usec single frequency/emitters
• < 1 usec multiple frequency/emitters
• Spurious/Harmonics 2.2.1.5.1. Spurs: < -15 dBc
• Harmonics: < -10 dBc
• Phase Noise
• -55 dBc at 10 kHz offset for a 10 GHz carrier for a single frequency emitter, single emitter.
• Intrapulse Modulation
• Frequency Modulation
• Deviation/Rate: ± 50 MHz / 20 usec
• Accuracy: ± 5 MHz
• Resolution: 500 kHz
• Phase Modulation (Bi-Phase)
• Chip Width: 100 nsec Min.
• Number of Chips: Up to 32 chips
• Pulse Modulation
• Pulse Repetition Interval;
• PRI Range: 1 usec Min.
• PRI Accuracy: ± (15 nsec + 10 ppm of programmed PRI)
• PRI Resolution: 50 nsec
• PRI Jitter/Stagger: Greater than or equal to 1% and up to 99% change of either the PW or PRI (average pulse interval can be either PW or PRI).
• Pulse Width
• PW Range: 50 nsec Min.; CW
• PW Accuracy: ± (25 nsec + 10 ppm of programmed PW)
• PW Resolution: 50 nsec
• Pulse Width Rise/Fall Time: > 15 nsec / 15 nsec
• On/Off Ratio: 60 dB
• Types: CW, Pulse, Agile, Jitter, Random, Doublet, Triplet, User Defined
• Amplitude Modulation
• Amplitude Range: 45 dB
• Accuracy (relative): The great of ± 2 dB or ± 10% of programmed value, with 5 dB min background attenuation.
• Resolution: 0.5 dB minimum
• Settling Time: < 1 usec
• Modulation Rate: 0.005 Hz – 2 kHz
• Accuracy: 0.005 Hz, ± 0.02%
• Resolution: 0.005 Hz
• Scan Modulation Types: Conical, raster, helical, sector, dwell, height finder, circular, palmer modifier, orthogonal, Loro, spiral.
• Power Levels 2.2.5.1. Min-Max Power Level: -70 dBm to +20 dBm
2.3. Receiver for Optional Extended Low Frequency Receiver
• Frequency Range (Carrier): 10 MHz to 500 MHz
• Frequency Accuracy (Absolute) 2.3.1.2.1. ± 0.001% for a single frequency emitter
• ± 5 MHz for multiple emitters or multiple frequency, single emitters
• Frequency Resolution: > 500 kHz
• Frequency Switching Time:
• < 200 usec single frequency/emitters
• < 1 usec multiple frequency/emitters
• Spurious/Harmonics
• Spurs: < -50 dBc
• Harmonics: < -10 dBc
• Phase Noise 2.3.1.6.1. -55 dBc at 10 kHz offset for a 10 GHz carrier for a single frequency emitter, single emitter.
• Intrapulse Modulation
• Frequency Modulation
• Deviation/Rate: ± 50 MHz / 20 usec
• Accuracy: ± 5 MHz
• Resolution: 500 kHz
• Phase Modulation (Bi-Phase)
• Chip Width: 100 nsec Min.
• Number of Chips: Up to 32 chips
• Pulse Modulation
• Pulse Repetition Interval;
• PRI Range: 1 usec Min.
• PRI Accuracy: ± (15 nsec + 10 ppm of programmed PRI)
• PRI Resolution: 50 nsec
• PRI Jitter/Stagger: Greater than or equal to 1% and up to 99% change of either the PW or PRI (average pulse interval can be either PW or PRI).
• Pulse Width
• PW Range: 50 nsec Min.; CW
• PW Accuracy: ± (25 nsec + 10 ppm of programmed PW)
• PW Resolution: 50 nsec
• Pulse Width Rise/Fall Time: > 15 nsec / 15 nsec
• On/Off Ratio: 60 dB
• Types: CW, Pulse, Agile, Jitter, Random, Doublet, Triplet, User Defined
• Amplitude Modulation
• Amplitude Range: 45 dB
• Accuracy (relative): The great of ± 2 dB or ± 10% of programmed value, with 5 dB min background attenuation.
• Resolution: 0.5 dB minimum
• Settling Time: < 1 usec
• Modulation Rate: 0.005 Hz – 2 kHz
• Accuracy: 0.005 Hz, ± 0.02%
• Resolution: 0.005 Hz
• Scan Modulation Types: Conical, raster, helical, sector, dwell, height finder, circular, palmer modifier, orthogonal, Loro, spiral.
• Power Levels
• Min-Max Power Level: -70 dBm to +20 dBm
3. Contractor Responsibilities
• A. Calibration Services
• Perform detailed calibration of RWR systems IAW applicable TOs and OEM specifications.
• Use certified, calibrated test equipment meeting MIL-STD requirements.
• Provide documentation for each calibration, including before/after metrics.
• Verify all components operate within required tolerances.
• B. Preventive Maintenance
• Inspect RWR systems for wear or damage during calibration.
• Repair/replace defective components with government approval.
• Run diagnostics to confirm functionality.
• C. Test and Verification
• Conduct operational checks post-calibration.
• Perform tests for frequency, sensitivity, and power output.
• Submit test data to the Contracting Officer’s Representative (COR).
• D. Reporting and Documentation
• Submit Calibration Certification upon service completion.
• Maintain detailed records of calibrations and equipment used.
• Submit monthly performance reports by the 5th of each month.
4. Performance Standards and Metrics Task Performance
Standard AQL Monitoring Method
Calibration Accuracy
Calibrated to TO specifications
100% technical compliance
Review of calibration data
Timeliness 3 calendar days per system
95% completed on schedule
Schedule tracking
Documentation Complete and accurate submissions
100% submission rate
Document review
5. Deliverables Deliverable Due Date Recipient
Calibration Certification Within 24 hours of completion
Contracting Officer’s Representative (COR)
Monthly Performance Report
5th of each month COR
• Contractor shall implement a Quality Control Plan (QCP).
• Government will evaluate contractor performance using a Quality Assurance Surveillance Plan (QASP).
6. Additional Sections Refer to original proprietary technical data document for detailed technical specifications covering receiver bands, amplitude modulation, pulse modulation, and additional requirements.
7. Installation & Cleanup Requirements
Contractor will not be on-base.
8. Site Visit Not Applicable
9. Special Requirements Contract funded annually
10. Points of Contact Please include all POCs in correspondence.
11. Base Entry Not Required
12. Security Requirements Not Applicable
13. Period of Performance FY25: 30 Sept 2025 - 29 Sept 2026 FY26: 30 Sept 2026 - 29 Sep 2027 FY27: 30 Sept 2027 - 29 Sep 2028 FY28: 30 Sept 2028 - 29 Sep 2029 FY29: 30 Sept 2029 - 29 Sep 2030
Item # Manufacturer/Description/Part/Model Number* Base year:
FY26: 30 Sept 2025 - 29 Sept
Model 527 Calibration S/N 000119/S/N 000097 /S/N 000109/ S/N 000101/ S/N 000115 /39300-
40002-10 Option Year 1:
FY27: 30 Sept 2026 - 29 Sep
Model 527 Calibration S/N 000119/S/N 000097 /S/N 000109/ S/N 000101/ S/N 000115 /39300-
40002-10 Option Year 2:
FY28: 30 Sept 2027 - 29 Sep
Model 527 Calibration S/N 000119/S/N 000097 /S/N 000109/ S/N 000101/ S/N 000115 /39300-
40002-10 Option Year 3:
FY29: 30 Sept 2028 - 29 Sep
Model 527 Calibration S/N 000119/S/N 000097 /S/N 000109/ S/N 000101/ S/N 000115 /39300-
40002-10 Option Year 4:
FY29: 30 Sept 2029 - 29 Sep
Model 527 Calibration S/N 000119/S/N 000097 /S/N 000109/ S/N 000101/ S/N 000115 /39300-
40002-10
14. Inspection & Acceptance FY26: Complete by 30 Sep 2026 FY27: Complete by 30 Sep 2027 FY28: Complete by 30 Sep 2028 FY29: Complete by 30 Sep 2029 FY30: Complete by 30 Sep 2030
| 1. Description of Services |
| 2. Current Technical Equipment |
| 3. Contractor Responsibilities |
| 4. Performance Standards and Metrics |
| 6. Additional Sections |
| 7. Installation & Cleanup Requirements |
| Contractor will not be on-base. |
| 8. Site Visit |
| 9. Special Requirements |
| 10. Points of Contact |
| 11. Base Entry |
| 12. Security Requirements |
| 13. Period of Performance |
File details come from the government source that posted it. Updated .