EATTACHMENT 1
PERFORMANCE WORK STATEMENT
FOR
SIGNAL GENERATOR REPAIR
523rd Electronics Maintenance Squadron (523 EMXS)
Hill Air Force Base
3 May 2020
TABLE OF CONTENTS
1. Scope 3
2. Basic Services 3
3. Service Summary 3
4. General Information 3
5. Appendices 4
1. SCOPE
The contractor shall provide all labor, tools, and parts necessary to provide a one time repair for seven signal generators in support of the 309th Electronic Maintenance Group (309 EMXG). The spare parts support test stands located in the 523rd Electronic Maintenance Squadron, Microwave Shop (Building
100, Bay A), Hill Air Force Base, Utah 84056.
2. BASIC SERVICES
2.1 The contractor shall repair seven 83620B Signal Generators, bringing them to a fully functional, calibrated state in accordance with OEM standards These items are outlined in
Appendix D.
2.2 The government will ship the defective pieces of equipment to the contractor’s facility for repair.
2.3 If the contractor is unable to complete a repair on a particular item, then the contractor shall provide a new or refurbished unit to the government. The refurbished unit must be of the same manufacturer, the same model, and with equal options.
2.4 Once repairs are completed, the contractor shall perform a functionality check and calibration in accordance with OEM standards. The contractor shall provide individual certificates of calibration.).
2.5 After all repairs and calibrations are completed, the contractor shall ship the repaired units back to Hill AFB.
2.6 The contractor shall provide a 90 day warranty on repaired units so that the government can ensure the original failures have been corrected and that units function properly for our applications.
3. SERVICES SUMMARY
Performance Objective PWS Para Performance Threshold
After repairs are completed the contractor shall perform a final functionality check.
2.3 Verified 100% test passed by SLT
4. GENERAL INFORMATION
4.1 . QUALITY CONTROL
4.1.1. In performing work under this contract, the contractor shall:
Refer to the CO any matter concerning a change to the scope, prices, terms or conditions of this contract.
Perform tasks to Rate Tables, maintaining rate tables to Original Equipment
Manufacturer specifications.
4.2. GOVERNMENT FURNISHED PROPERTY (GFP)
4.2.1 The Government will provide a document at the time of proposal and when award is made that indicates all GFP by model number, serial number and quantity.
4.2.2. The contractor is liable for any loss, damage, destruction, or theft of GFP after the contractor receives the GFP and is returned to the Government.
4.2.3. The contractor is responsible for returning all GFP to the Government after repair is complete at the destination specified in the contract, FOB destination unless directed otherwise in writing by the CO.
5. APPENDICES
A. Acronyms and Abbreviations List
B. Equipment List
APPENDIX A
ACRONYMS AND ABBREVIATIONS LIST
AFI Air Force Instruction
AFMC Air Force Material Command
CO Contracting Officer
EMXS Electronics Maintenance Squadron
GFP Government Furnished Property
OEM Original Equipment Manufacture
PWS Performance Work Statement
APPENDIX B
Parts List
QTY Model:
Serial
Number Known Faults
1 83620B Signal Generator 3844A01680 Output attenuator's accuracy is intermittent. (Self-tests pass)
1 83620B Signal Generator 3844A01586 Failing A5 and A6 self tests, output attenuator intermittent.
1 83620B Signal Generator 3844A01721 No output. Fails self-test 282 (YO Loop Locking), exhibited 18ghz amplitude issues and output attenuator accurancy issues prior to losing output.
1 83620B Signal Generator 3844A01596 Becomes unleveled from 17.929Ghz - 18.056Ghz. (Self-tests pass)
83620B Signal Generator 3844A01723 10Mhz-250Mhz amplitude fails accuracy. (Self-tests pass)
1 83620B Signal Generator 3844A01725 Output attenuator accuracy fails @ 18Ghz
1 83620B Signal Generator 3844A01563 Fails self tests for A4, A5, A6, A7, A9, 10, A11, A12, A13, A14, A15, A20 & all RF output self-tests.
File details come from the government source that posted it. Updated .