PWS-Salient Characteristics.doc
DOC document 80 KB Posted
- Solicitation number
- W911QX20Q0205
About this file
This solicitation requests proposals for one each Angle-Resolved Photoemission Spectroscopy tool, one each Scanning Tunneling Microscopy Cluster tool, and one each Hand-Off Chamber interconnected by an ultra-high vacuum transfer mechanism. Offerors must meet minimum specifications including an energy resolution of less than 1.8 milli-electron-volts for the ARPES tool. The solicitation is set aside for small businesses with less than 1,000 employees and is issued by the Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground. Proposals are due within 15 days of award with delivery required within 12 months of contract award. Evaluation criteria include technical approach, past performance, and price, with technical and past performance combined being more important than price.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| QandA.docx | DOCX document | |
| PWS-Salient Characteristics 0001.doc | DOC document | |
| Provisions and Clauses Full-Text Attachment (for Combo Synopsis-Solicitation).doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Commercial Availability Certification: I have evaluated the commercial marketplace and determined that all of the salient characteristics documented below are available in products/services offered in the commercial marketplace.
The Government requires one (1) each Angle-Resolved Photoemission Spectroscopy (ARPES) Tool, one (1) each Scanning Tunneling Microscopy (STM) Cluster Tool and one (1) each Hand-Off Chamber that are all interconnected by ultra-high-vacuum transfer mechanism and meet the following minimum specifications:
CLIN 0001 - Angle-Resolved Photoemission Spectroscopy (ARPES) Tool:
· Allow energy-momentum band mapping without sample rotation, tilt or motion during collection; with energy resolution of less than 1.8 milli-electron-volts (meV) and all control electronics, pumps to achieve <5 x 10-10 Torr and all software necessary for operation.
· Capable of x-ray photoelectron spectroscopy (XPS) using a monochromatic aluminum K-alpha radiation x-ray source.
· An electron flood gun to control sample charging during measurement to be included and located in a suitable location. Location such that electrostatic charging can be mitigated in real-time during measurement.
· The temperature of the ARPES sample stage shall be cooled by a cryogen-free closed-cycle helium (He) compressor-based refrigerator that can achieve a temperature of < Eight (8) Kelvin degrees and maintain that with a stability range of < 0.5 Kelvin degrees.
· Includes a Helium I and II ultra-violet (UV) differentially pumped light source and monochrometer, all control electronics, pumps and software necessary for operation. The source shall produce photon energy/linewidths of 21.2 electron-volts (eV) / < 1.2 x 10-3 eV and 41.8 eV / < 2 x 10-3 eV. Differential pumping to maintain vacuum of < 10-9 Torr during operation
· The sample manipulator of the ARPES tool shall allow computer control of at least five (5) degrees of freedom for sample manipulation and positioning.
· Allow a capability for resolving one (1) out-of-plane spin component, as well as at least one (1), preferably two (2), in-plane spin components.
CLIN 0002 - Scanning Tunneling Microscopy (STM) Cluster Tool:
· Capable of atomic-scale scanning tunneling microscopy (STM), atomic force microscopy (AFM) and scanning tunneling spectroscopy (STS) operational modes with cooling to < 125 Kelvin and base pressure of < 5 x 10-10 Torr with all control electronics, pumps and software necessary for operation.
· A low-energy-electron diffraction (LEED) for characterizing surface structure shall be included and located either in the hand-off/preparation chamber or the STM too with all control electronics, pumps and software necessary for operation.
CLIN 0003 - Hand-Off Chamber:
· Provides a wobblestick mechanism to exchange samples between a standard three (3) inch Varian/VEECO style molybdenum sample holder and a one (1) square centimeter flag-style holder.
· Provides Ultra-high Vacuum (UHV) connections, and gate valves isolating the connections, and mechanisms to move samples between the ARPES tool and the STM tool, and a Varian/VEECO style transfer tube that connects to a molecular beam epitaxy tool.
· Host an atomic hydrogen source to prepare oxide-free surfaces on samples, and shall include an ion source for sputter-cleaning surfaces, an electron beam source for simple evaporations, a low-energy-electron diffraction (LEED) for characterizing surface structure and all control electronics, pumps and software necessary for operation.
· Pumping techniques to achieve a base pressure of < 5 x 10-10 Torr, and a separate differential pumping capability for higher-pressure, dynamically pumped gas flows during sample cleaning.
· A separate vacuum suitcase, and port located at a suitable location on the cluster tool must be included for transfer of samples in and out of the cluster tool.
CLIN 0004: To include Shipping FOB Destination
Signature (typed name): __[REDACTED]__ Technical Point of Contact (TPOC) or Contracting Officer’s Representative (COR)
Contracting Officer:
Template last updated 07/28/2016