PWS Attachments - Exhibits.pdf
PDF 2 MB Posted
- Solicitation number
- W912P923R0039
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Technical Exhibit A General Location Map
Work area along Mississippi and Illinois Rivers
Technical Exhibit D-1 Contractor Contact Information
Technical Exhibit D-2
Contractor Available Equipment
Technical Exhibit D-3 Contractor Available Materials
Technical Exhibit D-4 Contractor Quality Control Plan
Technical Exhibit D-5
Contractor Accident Prevention Program
Technical Exhibit D-6
Contractor Accident Prevention Program Cont.
Technical Exhibit D-7 Contractor Job Hazard Analysis
ANNUAL PEST CONTROL REPORT
U.S. ARMY CORPS OF ENGINEERS
ST. LOUIS DISTRICT, RIVERS PROJECT OFFICE
Instructions on Back
PLANNED
OUTGRANT
ACTUAL YEAR
Name Number
APPLICATOR
Name Agency / Company Address City State Zip Phone Number ( ) License No.
AREA
County State
Area Measurement
Name Description
PEST
Description Quantity
PESTICIDE
Trade Name Quantity EPA Class EPA Reg.# Applications
Preparer Printed Name and Title Preparer Signature Date
OFFICAL USE ONLY Approved Disapproved
Approver Printed Name and Title Approver Signature Date
Reason for Disapproval / Notes on Approval
Technical Exhibit E-1
Instructions for Completing Annual Pest Control Report U.S. Army Corps of Engineers, St. Louis District, Rivers Project Office
Planned / Actual: Check either actual data for previous year or planned data for upcoming year.
Outgrant Name: If applicable, the agency, company or individual holding the lease, easement or permit.
Outgrant Number: If applicable, the lease, easement, or permit number.
Applicator Name / Agency / Company / Address / Phone Number: Pesticide applicator name, agency or company, address, and phone number.
Applicator License No. / State: Pesticide applicator license number and license state.
Area Measurement: Total measured area / volume of application area in acres, sq. yards, sq.
feet, cu. feet, etc.
Area Name: Application area common name, examples; River Access Area, Ag Field No. 24, Machinery compound, etc.
Area Description: Application area description, examples; restrooms, docks, shoreline riprap, cultivated field, food plot, levee, parking areas, fence line, trail, etc.
Pest Description: Target pests’ description, examples; Johnson grass, broadleaf weeds, woody vegetation, mosquitoes, spiders, mice, gophers, pigeons, etc.
Pest Quantity: Target pests estimated population by density, or other description, examples;
complete infestation, 4 plants / sq meter, 8 stems / acre, etc.
Pesticide Trade Name: Pesticide full trade name that appears on label, and common name if different than trade name.
Pesticide Quantity: Pesticide amount applied to the application area for each application described in gallons, quarts, pints, fluid ounces, etc.
Pesticide EPA Class: General-use or restricted-use. If restricted-use pesticide, include a written justification, including:
1. Specific reasons why a general-use pesticide cannot achieve an acceptable level of control.
2. Other technical guidance in the selection process, including specific contact names and recommendations received.
3. Specific actions taken to ensure that proper safeguards are employed in the application.
Pesticide EPA Reg. No.: Pesticide EPA registration number that appears on the label.
Pesticide Applications: Total number of pesticide applications for this area for the year.
Technical Exhibit E-2
Technical Exhibit F Boundary Line Work Specifications
4. Boundary Posts. Boundary posts shall be seven (7) foot, high tensile, high strength, hot-dip galvanized five sided flanged channel two (2) inch steel posts with three-eighths (3/8) inch pre-drilled holes, suitable for management and boundary signs placement.
5. Management Signs. Management signs shall be approved sign type, .080 gauge aluminum alloy, nine (9) inch by nine (9) inch, with reflective sheathing lettering and with two
(2) five-sixteenths (5/16} drilled holes to accommodate boundary posts.
6. Boundary Signs. Boundary signs shall be approved sign type, .080 gauge aluminum alloy, six (6) inch by six (6) inch, with reflective sheathing lettering and with two (2) five-sixteenths (5/16) drilled holes to accommodate boundary posts.
7. Boundary Post I Signs Placement. Boundary posts shall be placed;
(a) That a minimum of posts are placed, (b} On the boundary line,
(c) Seven (7) feet from all boundary line monuments, and
(1) Whenever the ground level obstructs the lower three (3) foot horizontal clearing limits, or
(2) Whenever the distance between boundary posts exceeds four hundred (400) feet.
(d) On public road and levee right-of-way lines,
(1) At the intersection of the boundary line,
(2) Seven (7) feet from the intersection of the boundary line offset from boundary lines within rights-of-way, and
(e) Whenever the distance between boundary posts exceeds four hundred (400) feet,
(f) Within five (5) degrees vertical,
(g) Within fifty-six (56) inches and fifty-two (52) inches extending above the ground surface,
(h) With the flanged side of the post open toward private property,
(i) With affixed management and/or boundary signs,
(1) With lettering facing private property,
(2) Within fifteen (15) degrees parallel of the boundary line,
(3) With the top of the top sign flush with the top of the boundary post, and
(4) With cap screws and nuts.
8. Witness Pots. Witness pos\s shall be five (5) foot six (6) inch, high tensile, high strength, hot-dip galvanized five sided flanged channel two (2) inch steel posts with three-eighths (3/8) inch pre-drilled holes, suitable for witness sign placement.
9. Witness Signs. Witness signs shall be approved sign type, .080 gauge aluminum alloy, three and three-quarter (3 3/4) inch by five and one-half (5 1/2) inch, with reflective sheathing lettering and with two (2) five-sixteenths (5/16) drilled holes to accommodate boundary posts.
10. Witness Post I Signs Placement. Witness posts shall be placed;
(a) Within six (6) inches of all line, reference and witness corner monuments,
(b) Within five (5) degrees of vertical,
(c) Within thirty-eight (38) inches and thirty-four (34) inches extending above the ground surface, (d With the flanged side of the post open toward private property,
(e) With affixed witness sign, {1) With lettering facing private property,
(2) With the top of the witness sign flush
(3) With the top of the witness post, and
(4) With cap screws and nuts.
11. Cap Screws ·and Nuts. Cap screws shall be five-sixteenths {5/16) inch diameter and one and one-half {1 1/2) inches length, zinc chromate coarse thread hex head standard strength low carbon steel grade two (2). Nuts shall be five sixteenths (5/16) inch zinc chromate coarse threaded steel full finished.
Exhibit F-1
RIVERS PROJECT BOUNDARY MAINTEANCE AND INSPECTION
REPORT FORM
Date:
Group No. / Work Area Personnel/Laborers:
Between Angle Point # and Angle Point # Coordinates: X Y Description of Problem:
Missing Monument Encroachment Other
Please Return Weekly.
Exhibit F-2
RIVERS PROJECT OFFICE BOUNDARY MAINTENANCE AND
INSPECTION MISSING ANGLE POINT MONUMENTS
Date:
Group No. / Work Area
AP#
Coordinates: X Y Notes:
Supervisor:
Exhibit F-3
RIVERS PROJECT BOUNDARY MAINTENANCE AND INSPECTION
NEXT WEEK’S WORK PROJECTION
Date:
Planned Group No. / Work Area
Planned hours of work for each day during the upcoming week:
Monday:
Tuesday Wednesday Thursday Friday
The following personnel will work during the upcoming week:
| St. Louis District |
| TABLE OF CONTENTS |
| SECTION 2 DEFINITIONS AND ACRONYMS |
| SECTION 3 ENVIRONMENTAL PROTECTION |
| SECTION 4 GOVENRMENT FURNISHED PROPERTY, EQUIPMENT AND SERVICES |
| SECTION 5 CONTRACTOR FURNISHED PERSONNEL, EQUIPMENT AND MATERIALS |
| SECTION 6 SERVICE DELIVERY SUMMARY |
| TECHNICAL EXHIBIT A – GENERAL WORK PERFORMANCE MAP 47 |
| TECHNICAL EXHIBIT D-1 – CONTRACTOR CONTACT INFORMATION 48 |
| TECHNICAL EXHIBIT D-2 – CONTRACTOR AVAILABLE EQUIPMENT 49 |
| TECHNICAL EXHIBIT D-3 – CONTRACTOR AVAILABLE MATERIALS 50 |
| TECHNICAL EXHIBIT D-4 – CONTRACTOR QUALITY CONTROL PLAN 51 |
| TECHNICAL EXHIBIT D-5 and D6 – CONTRACTOR ACCIDENT PREVENTION PROGRAM 52-53 |
| TECHNICAL EXHIBIT D-7 – CONTRACTOR JOB HAZARD ANALYSIS 54 |
| TECHNICAL EXHIBIT E-1 and E-2 - ANNUAL PEST CONTROL REPORT 55-56 |
| TECHNICAL EXHIBIT F – BOUNDARY LINE WORK SPECIFICATIONS 57-63 |
| TECHNICAL EXHIBIT F-1 – BOUNDARY MAINTENANCE AND INSPECTION REPORT FORM 64 |
| TECHNICAL EXHIBIT F-2 – BOUNDARY MAINTENANCE AND INSPECTION MISSING ANGLE POINT MONUMENTS REPORT 65 |
| TECHNICAL EXHIBIT F-3 – BOUNDARY MAINTENANCE AND INSPECTION WORK PROJECTION 66 |
| PERFORMANCE WORK STATEMENT (PWS) RIVERS PROJECT OFFICE |
| SECTION 2 DEFINITIONS AND ACRONYMS |
| SECTION 3 – ENVIRONMENTAL PROTECTION |
| SECTION 4 |
| SECTION 5 |
| SECTION 6 |
| ANNUAL PEST CONTROL REPORT |
| PLANNED OUTGRANT |
| APPLICATOR |
| AREA |
| PEST |
| PESTICIDE |
| Instructions for Completing Annual Pest Control Report |
| Exhibit F-1 |
| Exhibit F-2 |
| Exhibit F-3 |
File details come from the government source that posted it. Updated .