This is a Purchase Description document that specifies technical requirements and quantities for accelerometer sensors and related accessories.

The procurement requires three tri-axial accelerometer models: Model 7533A7-05 (±40g amplitude range, 20 mV/g sensitivity, 0-1500 Hz frequency range, operating temperature -40 to 257°F, 6 grams, integrated 6-wire cable 5 feet long) in quantity 10; Model 7603D5 (±50g amplitude range, 10 mV/g sensitivity, 0-2000 Hz frequency range, operating temperature -67 to 257°F, 38 grams, 4-pin M4.5 connector) in quantity 10; and Model 7603D7 (±200g amplitude range, 2.50 mV/g sensitivity, 0-3000 Hz frequency range, operating temperature -67 to 257°F, 38 grams, 4-pin M4.5 connector) in quantity 20. All accelerometers feature hermetically sealed construction with signal/ground isolated electrical configuration, variable capacitance technology with zero low-end frequency response, and a 5000g shock limit. The 7600 Series requires 3-11 Vdc excitation voltage while the 7500 Series requires 4-28 Vdc. Calibration certificates (physical copy and electronic data file) are required for each sensor. The procurement also includes cable assemblies (9-pin jack to pigtail in 30-foot, 50-foot, and 100-foot lengths in quantities 11, 20, and 10 respectively) and 30 adhesive mounting bases (aluminum anodized orange with specified tapped holes).

View the file

Other files

File Type Posted
Accelerometer Pre-Solicitation Notice.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Purchase Description

Technical Information

The accelerometer is a device that senses motion. The requirements for this purchase order are for accelerometers that sense motion in only one axis, a uniaxial accelerometer, and accelerometers packages that sense motion in 3 axes, a tri-axial accelerometer. The sensor converts movement to an electrical signal proportional to the acceleration of the movement. The models requested use variable capacitance technology to achieve a low-end frequency response of zero (0). There are three different models and measurement ranges specified for different applications.

Amplitude Range: Tri-axial Model 7603D5: +/- 50 g Tri-axial Model 7533A7-05: +/- 40 g

Tri-axial Model 7603D7: +/- 200 g

Sensitivity: Tri-axial Model 7603D5: 10 mV/g Tri-axial Model 7533A7-05: 20 mV/g

Tri-axial Model 7603D7: 2.50 mV/g

Minimum Excitation Voltage: 7600 Series Accelerometers: 3 Vdc 7500 Series Accelerometers: 4 Vdc

Maximum Excitation Voltage: 7600 Series Accelerometers: 11 Vdc

7500 Series Accelerometers: 28 Vdc

Shock Limit: 5000 g

Frequency Range +/-3db: Tri-axial Model 7603D5: 0-2000 Hz

Tri-axial Model 7533A7-A5: 0-1500 Hz Tri-axial Model 7603D7: 0-3000 Hz

Operating Temperature Range: Tri-axial Model 7603D5: -67 to 257 deg. F

Tri-axial Model 7533A7-A5: -40 to 257 deg. F Tri-axial Model 7603D7: -67 to 257 deg. F

Weight: Tri-axial Model 7603D5: 38 grams

Tri-axial Model 7533A7-A5: 6 grams Tri-axial Model 7603D7: 38 grams

Construction: Hermetically sealed Electrical Configuration: Signal/ground isolated Physical Signal Output Medium: 7600 Series Accelerometers: 4-pin M4.5 connector

7500 Series Accelerometers: integrated 6-wire cable, 5 feet long

Calibration: Calibration certificate, physical copy and electronic data file, required for each sensor.

Requirement Table:

Model # / Description Quantity

7533A7-05 DC ACCELEROMETER,+/-

40G, TRIAXIAL, INTEGRAL CABLE 5 FT

7603D5 TRIAXIAL DC

ACCELEROMETER, 50g

7603D7 TRIAXIAL DC

ACCELEROMETER, 200g

6964A30 CABLE ASSY, 9 PIN JACK TO

PIGTAIL, 30FT

69026 ADHESIVE MOUNTING BASE, 2X

8-32, 1X 10-32 TAPPED HOLES,

ALUMINUM ANODIZED, ORANGE

6964A50 CABLE ASSY, 9 PIN JACK TO

PIGTAIL, 50FT

6964A100 CABLE ASSY, 9 PIN JACK TO

PIGTAIL, 100 FT