This solicitation is for a parking lot expansion project at the U.S. Embassy in Lusaka, Zambia. The project involves expanding three existing parking lots located west of the Chancery building, north of the Utility Building, and in the current staff parking area. Work will cover approximately 730 square meters and includes earthworks, demolition, concrete work, paving, steel work, painting, minor electrical and plumbing, tree removal and replanting. The contractor's employees will be escorted while on site. The contracting officer's representative will oversee work, which will be carried out in phases to allow traffic flow. The contractor must provide temporary hoarding and agree to a phasing plan with the embassy. The solicitation was issued by the Department of State under number 19ZA6024PR12253735.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0+10400+1046 0+1065

0+1070

400mm Razor wire

NEW FENCE ARRANGEMENT BETWEEN CHAINAGE 1040 AND 1070 - NORTH

STRUCTURAL

NOTES:

AutoCAD SHX Text No.

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

AMENDMENTS

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

REFERENCE DRAWINGS

AutoCAD SHX Text DRAWING No.

AutoCAD SHX Text

TITLE

AutoCAD SHX Text

APPROVALS HE DOES SO ENTIRELY AT HIS OWN RISK.

AutoCAD SHX Text

SHOULD THE CONTRACTOR PROCEED WITHOUT THE ABOVE

AutoCAD SHX Text

INFORMATION SHOWN ON THE DRAWING AND DIMENSIONS

AutoCAD SHX Text

CONTRACTOR TO CHECK AND VERIFY SUFFICIENCY OF

AutoCAD SHX Text

IMMEDIATELY REPORTED TO THE PROJECT MANAGER.

AutoCAD SHX Text

ANY OMMISIONS, DISCREPANCIES OR ERRORS TO BE

AutoCAD SHX Text

FIGURED DIMENSIONS ON DRAWINGS TO BE GIVEN PRIORITY

AutoCAD SHX Text

GENERAL NOTES:

AutoCAD SHX Text

BEFORE COMMENCING WORK.

AutoCAD SHX Text

OVER SCALING.

AutoCAD SHX Text 3.

AutoCAD SHX Text 2.

AutoCAD SHX Text 1.

AutoCAD SHX Text JOB No.:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text DRG.No.:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text G

AutoCAD SHX Text F

AutoCAD SHX Text

PROJECT DESCRIPTION:

AutoCAD SHX Text

LUSAKA STAFF PARKING

AutoCAD SHX Text

PROPOSED FENCE ELEVATION

AutoCAD SHX Text

CHAINAGE 1040 TO 1070

AutoCAD SHX Text October 2023

AutoCAD SHX Text

C/NEC/P/2023/02

AutoCAD SHX Text 1:75

AutoCAD SHX Text

CHUMA

AutoCAD SHX Text

CHUMA

AutoCAD SHX Text

CHUMA

AutoCAD SHX Text 4 REINFORCEMENT COVER TO BE 40mm FOR BEAMS AND .

AutoCAD SHX Text

5 ALL DOWELS TO 16MM 400MM LONG.

AutoCAD SHX Text 3 SOLID CONCRETE BLOCKS TO HAVE MINIMUM 15Mpa .

AutoCAD SHX Text

1. ALL CONCRETE 25Mpa UNLESS STATED

AutoCAD SHX Text

2. ALL REINFORCEMENT TO BE HIGH TENSILE STEEL WITH

AutoCAD SHX Text A MINIMUM YIELD STRENGTH OF 450Mpa EXCEPT LINKS

AutoCAD SHX Text TO BE MILD STEEL 250MpA YIELD STRENGTH

AutoCAD SHX Text

COMPRESSIVE STRENGTH

AutoCAD SHX Text

AND 75MM WHERE CAST AGAINST EARTH