Proposed_Fence_Layout_325014.pdf
PDF 2 MB Posted
- Attached to
- Albion Facility Perimeter Fence Installation
- Solicitation number
- 325014
- Issued by
- Dane County, Eau Claire City, Wisconsin
About this file
This document is a detailed fence layout plan for the Dane County Albion Highway Garage Facility located in Wisconsin, specifically for a perimeter fence installation project along County Highway A. The site plan depicts a proposed fence configuration with precise measurements, including a 495' x 450' boundary, an entry gate with a 25' swing gate on the right side of the entrance, and a 45' rolling gate for facility access. Key design elements include an open path for the rolling gate, a fence gate, and specific instructions to remove all perimeter obstructions by the owner. The proposed fence offset will be finalized at a pre-bid meeting, and the project is associated with Request for Bid (RFB) No. 325014, with electronic bid submissions due by 2:00 p.m. on June 3rd, 2025.
The site plan shows the fence surrounding the Tow Plow Building and existing infrastructure, with careful consideration of edge of pavement, existing right of way, and site-specific geometric constraints. While specific budget details are not provided in this document, the plan suggests a comprehensive approach to securing the county highway facility's perimeter. The drawing is part of the WisDOT/CADDS system, plotted on September 12, 2024, and includes technical annotations such as rebar and geographic markers that indicate a professionally surveyed and engineered design for the fence installation project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Albion_Facility_Perimeter_Fence_Installation_(Addendum_#2_Revision).pdf | ||
| 325014_Final_RFB.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
495'
450'
307'
50'
193'
79'
101'
REBAR
REBAR
REBAR
REBAR
GS
IP
EXISTING RIGHT OF WAY
PROPOSED FENCE
CTH
A
66'
72'
39'
22'
22'
29'
173'
TOW PLOW BUILDING
70' 12'
12'
EDGE OF PAVEMENT
EDGE OF PAVEMENT
WISDOT/CADDS SHEET 42
EHWY: COUNTY:
H:\ENGINEER\ACAD-DWG\PROJECT\FACILITIES\ALBION\PROPOSED FENCE LAYOUT.DWGFILE NAME : 9/12/2024 4:05 PMPLOT DATE : PLOT BY : RACH, JEREMY
PROJECT NO:
PLOT NAME :
SHEET
PLOT SCALE : 1 IN:100 FT
XXXX-XX-XX CTH A DANE ALBION SHOP FENCE DETAIL
LAYOUT NAME - Plan 1 IN 40 FT
AutoCAD SHX Text
IP
DZM11
Callout Fence Gate
DZM11
Line
DZM11
Callout Entry Gate
DZM11
Line
DZM11
Arrow
DZM11
Callout Open path of 45' rolling gate
DZM11
Callout All perimeter obstructions to be removed by owner.
DZM11
Length Measurement 5'-0"
DZM11
Line
DZM11
Length Measurement 5'-0"
DZM11
Line
DZM11
Line
DZM11
Line
DZM11
Line
DZM11
Line
DZM11
Line
DZM11
Callout Proposed Fence Offset (Final Offset to be determined at Pre-Bid meeting)
DZM11
Cloud+
DZM11
Cloud+ 25'' swing gate on the right side of entrance
| Sheets and Views |
| Proposed Fence Layout-Plan 1 IN 40 FT |
File details come from the government source that posted it. Updated .