Project Drawings - WVDNR Chief Logan Rec Center Pool HVAC Renovation 12Oct26.pdf

PDF 2 MB Posted

Attached to
Chief Logan Rec Center New HVAC Construction
Solicitation number
CRFQ 0310 DNR2700000010 1
Issued by
Lewis County, West Virginia

About this file

This file contains project drawings for the West Virginia Department of Natural Resources (WVDNR) Chief Logan Recreation Center Pool HVAC Renovation. The drawings document the mechanical, electrical, and plumbing systems required for the HVAC renovation project at the facility. The project scope includes the design and installation of heating, ventilation, and air conditioning systems to support the recreation center's pool operations. The drawings serve as technical specifications and visual representations of the proposed system layouts, equipment placement, and integration points with existing building infrastructure necessary for contractors to prepare accurate bids and execute the renovation work.

The project drawings establish the technical baseline and design standards that bidders must follow in their proposals and project execution. As design documentation rather than a solicitation document, the drawings do not independently establish pricing terms, set-asides, contract award dates, or term conditions. These parameters would be detailed in the accompanying bid solicitation, contract specifications, or procurement notices issued by WVDNR for the Chief Logan Recreation Center Pool HVAC Renovation project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PENNSYLVANIA OFFICE

429 LAUREL RUN ROAD

CARMICHAELS, PA 15320

PHONE: (724) 966 - 5655

WEST VIRGINIA OFFICE

54 WEST RUN RD

MORGANTOWN, WV 26508

PHONE: (304) 291 - 2234

WVDNR CHIEF LOGAN REC CENTER POOL HVAC

RENOVATION

MEI PROJECT #26010

DWG TITLE

GENERAL

G000 COVER PAGE

G101 EXISTING & NEW FLOOR PLANS

G102 ENLARGED PLANS & DETAILS

MECHANICAL

M000 MECHANICAL ABBREVIATIONS

M001 MECHANICAL DUCTWORK DEMO PLAN

M101 MECHANICAL DUCTWORK PLAN

M102 MECHANICAL PIPING PLAN

M401 ENLARGED MECHANICAL DUCTWORK PLAN

M402 ENLARGED MECHANICAL PIPING PLAN PLAN

M501 MECHANICAL DETAILS

M601 MECHANICAL SCHEDULES

M901 MECHANICAL PERSPECTIVE

ELECTRICAL

E000 ELECTRICAL ABBREVIATIONS

E001 ELECTRICAL DEMO POWER PLAN

E101 ELECTRICAL POWER PLAN

E102 ELECTRICAL POWER PLAN

E103 ELECTRICAL LIGHTING PLAN

E601 ELECTRICAL SCHEDULES & DETAILS

CHEM STG

62 SF

SPRINKLER

22 SF

POOL

103A

3381 SF

POOL DECK

4843 SF

POOL HEATER

105A

97 SF

ELEC

73 SF

POOL MECH

507 SF

MEN'S

SHOWERS/LOCKERS

773 SF

WOMEN'S

SHOWERS/LOCKERS

773 SF

STORAGE

195 SF

VENDING

124 SF

OFFICE

245 SF

LOBBY

550 SF

VEST

131 SF

JAN

103 SF

COURTS

23465 SF

POOL

103A

3381 SF

POOL DECK

4761 SF

VEST

131 SF

LOBBY

550 SF

OFFICE

245 SF

JAN

103 SF

STORAGE

195 SF

VENDING

124 SF

WOMEN'S

SHOWERS/LOCKERS

773 SF

MEN'S

SHOWERS/LOCKERS

773 SF

POOL MECH

507 SF

ELEC

73 SF

POOL HEATER

105A

97 SF

CHEM STG

62 SF

COURTS

23465 SF

SPRINKLER

22 SF

BOILER ROOM

104A

73 SF

G102

INSTALL NEW FLOAT VALVE ON

EXISTING PADDOCK VACSAND FILTER

CUT 16" x 16" HOLE AND INSTALL METAL ANGLE

PICTURE FRAME OF 1/4" STEEL PROVIDE FULL

COVERAGE STAINLESS STEEL PIANO HINGED LOCKING

DOOR FOR BULK CHLORINE FILL VALVE HOSE ACCESS PA OFFICE:

429 LAUREL RUN ROAD

CARMICHAELS, PA 15320

PH: (724) 966-5655

WV OFFICE:

54 WEST RUN RD.

MORGANTOWN, WV 26508

PH: (304) 291-2234

SHEET NAME:

MILLER ENGINEERING INC.

COPY RIGHT:

CHECKED BY:

DRAWN BY:

DESIGNED BY:

BCM

SEAL:

CONSULTANT:

PROJECT NAME:

PROJECT OWNER:

PROJECT STATUS:

PROJECT NUMBER:

ORIGINAL PAGE SIZE: 22x34

G101

EXISTING & NEW

FLOOR PLANS

12 OCT 2026

TRT

BCM

26010.1

ISSUED FOR

CONSTRUCTION

WVDNR

WVDNR CHIEF

LOGAN REC CENTER

POOL HVAC

RENOVATION

N O

D

ES

C

R

IP

TI

O

N D

A

TE

1/8" = 1'-0"1

EXISTING FIRST FLOOR PLAN

1/8" = 1'-0"2

NEW WORK FIRST FLOOR PLAN

104A

SPRINKLER

22 SF

POOL DECK

4761 SF

BOILER ROOM

104A

73 SF

G 3a

EXISTING

COLUMN WRAP

20' - 2 3/8"

4'

1/

4"

4' - 10"

G102

104A

G102

2' X 4' SIGN "CEILING ABOVE

NOT RATED FOR STORAGE"

SIGN BY OTHERS.

104A

ADOOR TYPE

1FRAME TYPE

FLUSH

# WIDTH

SOUND RATING

FIRE RATING

X

7/8" 1-5/8" 2-1/2" 3-5/8"

4" 5-1/2"

6"

8"

NONE

#G GYPSUM AND STEEL STUD TO CEILING - NO

INSULATION 45 STC RAL-TL99-103a

16 GA STRUCTURAL 6"

METAL STUD @ 16" O.C.

MOISTURE- AND MOLD-

RESISTANT 5/8" GYP. BOARD

MECHANICALLY FASTEN

BOTTOM TRACK TO FLOOR

SLAB @ 24" OC MAX

MOISTURE- AND MOLD-

RESISTANT 5/8" GYP. BOARD

PLAN

BASE

CEILING

WATER GUARD DRYWALL TRIM

CEILING

NOTE: PROVIDE CAULKING

AROUND ALL WALL

PENETRATIONS

DOUBLE TOP TRACK

RUBBER BASE

MARINE GRADE

3/4" PLYWOOD

16 GA STRUCTURAL 6"

METAL STUD @ 16" O.C.

MOISTURE- AND

MOLD-RESISTANT

5/8" GYP. BOARD

FASTEN TO

EXTERIOR WALL

SEAL ALL

PENETRATIONS

PER MEP

9'

0"

2" X 2" ALUMINUM

TRIM ALL SIDES

PA OFFICE:

429 LAUREL RUN ROAD

CARMICHAELS, PA 15320

PH: (724) 966-5655

WV OFFICE:

54 WEST RUN RD.

MORGANTOWN, WV 26508

PH: (304) 291-2234

SHEET NAME:

MILLER ENGINEERING INC.

COPY RIGHT:

CHECKED BY:

DRAWN BY:

DESIGNED BY:

BCM

SEAL:

CONSULTANT:

PROJECT NAME:

PROJECT OWNER:

PROJECT STATUS:

PROJECT NUMBER:

ORIGINAL PAGE SIZE: 22x34

G102

ENLARGED PLANS &

DETAILS

12 OCT 2026

TRT

BCM

26010.1

ISSUED FOR

CONSTRUCTION

WVDNR

WVDNR CHIEF

LOGAN REC CENTER

POOL HVAC

RENOVATION

N O

D

ES

C

R

IP

TI

O

N D

A

TE

1/2" = 1'-0"1

NEW WORK FIRST FLOOR PLAN - ENLARGED BOILER ROOM

1/2" = 1'-0"2 104A

DOOR SCHEDULE

FIRE

RATING WIDTH HEIGHT

PANEL FRAME

NOTES #TYPE MATL TYPE MATL

104A 6' - 0" 7' - 0" AA HM 1 HM 104A

1.

DOOR SCHEDULE NOTES:

EXTERIOR RATED W/ WEATHER STRIPPING, STOREROOM FUNCTION, INACTIVE LEAF W/ MANUAL FLUSH BOLTS.

DOOR TYPES

1/2" = 1'-0"3

WALL SECTION

PAINT WALLS, DOOR , AND PLYWOOD TO MATCH EXISTINGPAINT WALLS, DOOR , AND PLYWOOD TO MATCH EXISTING

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

WIRING IS SHOWN ON DRAWINGS ONLY FOR SPECIFIC ROUTES

OR SPECIAL CONDITIONS. ALL WALL MOUNTED DEVICES ARE

FINAL HEIGHT BY. ARCH.

WIRING AND CONDUIT OR MC CABLE SHALL BE REQUIRED FOR

ALL OUTLETS AND DEVICES. FOLLOW INDICATED CIRCUITS

NUMBERS AND PANEL DESIGNATION. OBTAIN PRIOR APPROVAL

OF ENGINEER FOR DEVIATIONS.

ALL 15A AND 20A, 115V AND 120V RECEPTACLES LOCATED IN

DWELLING UNITS SHALL BE TAMPER RESISTANT.

ALTHOUGH ALL BRANCH CIRCUIT WIRING IS NOT SHOWN, IT IS

THE INTENT OF THESE DOCUMENTS THAT A COMPLETE

BRANCH CIRCUIT WIRING SYSTEM BE INSTALLED.

ALL NEUTRALS SHALL BE FULL CAPACITY. THE USE OF SHARED

OR COMMON NEUTRALS IS PROHIBITED ON ALL ELECTRIC

WIRING.

PROVIDE CONTROL AND FIRE ALARM WIRE AS NECESSARY TO

INSTALL ALL SYSTEMS DEVICES AND PANELS FOR COMPLETE

SYSTEMS. FINAL CONNECTION TO PERMANTLY MOUNTED

EQUIPMENT IS PART OF THE ELECTRICAL SCOPE OF THIS

PROJECT.

PROVIDE TEL/DATA AND CAT5 AS INDICATED. REVIEW DATA,

SWITCH, RECEPTACLE, ETC LOCATIONS AND HEIGHTS WITH

OWNER PRIOR TO INSTALLATION.

ALL INTERIOR WIRING SHALL BE THHN/THWN IN METAL CONDUIT

OR MC CABLE. MAX OF 3'-0" OF FLEXIBLE CONDUIT MAY BE

USED FOR FINAL EQUIPMENT TERMINATIONS.

EXTERIOR WIRING IS TO BE THHN/THWN IN PVC CONDUIT. MAX.

OF 3'-0" OF FLEXIBLE METALLIC SEATITLE CONDUIT MAY BE

USED TO EXTERIOR EQUIPMENT.

TV AND TELEPHONE CABLING SHALL BE INSTALLED FROM

LOCATIONS INDICATED ON DRAWINGS TO DEMARC LOCATION.

COORDINATE FINAL DEMARC LOCATIONS w/ TV AND

TELEPHONE COMPANY.

GROUP AND TRAIN ALL TEL/DATA AND CABLE TV CABLE.

SUPPORT FROM STRUCTURE.

VERIFY ALL FIELD CONDITIONS AND MEASUREMENTS PRIOR TO

BIDDING. COORDINATE ALL WORK WITH OTHER TRADES.

COORDINATE ALL CEILING MOUNTED DEVICES WITH ALL OTHER

TRADES PRIOR TO INSTALLATION.

PERFORM ALL WORK IN ACCORDANCE WITH 2020 NEC.

COORDINATE FINAL FIXTURE LOCATIONS WITH OWNER AND

GENERAL CONTRACTOR PRIOR TO INSTALLATION OF CEILING.

FINAL COORDINATION OF SCOPE OF WORK , DIMENSIONS,

FIXTURE PLACEMENT, ROUTINGS, ETC IS THE RESPONSIBILITY

OF THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS

PRIOR TO BIDDING.

ELECTRICAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

PROVIDE FIRE ALARM WIRING AND CONDUIT AS

NECESSARY TO MEET CODES, STANDARDS AND

REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION

(AHJ).

PROVIDE WIRING AND CONDUIT AS NECESSARY TO

INSTALL ALL FIRE ALARM DEVICES AND PANELS FOR A

COMPLETE SYSTEM.

RETAIN THE SERVICES OF A NICET LEVEL 3 OR 4

SYSTEM DESIGNER TO DESIGN A COMPLETE FIRE

ALARM SYSTEM AS NECESSARY TO MEET CURRENT

NFPA, STATE AND LOCAL REQUIREMENTS.

PROJECT DRAWINGS ARE DIAGRAMMATIC IN NATURE.

PROVIDE HORN/STROBES AS SHOWN AND SUPPLEMENT

AS NECESSARY TO MEET REQUIREMENTS OF CURRENT

NFPA, STATE AND LOCAL REQUIREMENTS. OBTAIN ALL

NECESSARY APPROVALS PRIOR TO INSTALLATION OF

SYSTEM. OBTAIN FINAL INSPECTION AS REQUIRED BY

AHJ AND INSURANCE UNDERWRITERS.

PROVIDE DUCT DETECTORS IN ACCORDANCE w/ NFPA

STANDARDS IN THE RETURN STREAM FOR ALL AIR

SYSTEMS 2,000 CFM & GREATER ALONG W/ THE SUPPLY

STREAM FOR SYSTEMS 15,000 CFM & GREATER.

FIRE ALARM WIRING IS TO BE IN CONDUIT OR MC CABLE

APPROPRIATELY LABELED AS REQUIRED BY NFPA 72.

PERFORM ALL WORK IN ACCORDANCE w/ NFPA 72 AND

2020 NEC.

FINAL COORDINATION OF SCOPE OF WORK,

DIMENSIONS, FIXTURE PLACEMENT, ROUTING, ETC IS

THE RESPONSIBILITY OF THE GENERAL CONTRACTOR

AND ALL SUB-CONTRACTORS PRIOR TO BIDDING.

VERIFY ALL FIELD CONDITIONS AND MEASUREMENTS

PRIOR TO BIDDING. COORDINATE ALL WORK w/ OTHER

TRADES. COORDINATE ALL CEILING MOUNTED DEVICES

w/ ALL OTHER TRADES PRIOR TO INSTALLATION.

FIRE ALARM NOTES

LIGHTING LEGEND

SINGLE POLE SWITCH

3: THREE WAY

4: FOUR WAY

D: DIMMING

3D: THREE WAY DIMMING

K: KEYED

O: SWITCH W/ INTEGRAL OCCUPANCY SENSOR

OS

OCCUPANCY SENSOR. PROVIDE POWER SUPPLIES & ALL

ANCILLARY DEVICES AS NECESSARY FOR A COMPLETE

INSTALLATION.

ELECTRICAL LEGEND

120V, 20A, DUPLEX / QUADRUPLEX RECEPTACLE

G: GFCI

C: MOUNTED 6" ABOVE COUNTER HEIGHT

CG: GFCI, MOUNTED 6" ABOVE COUNTER HEIGHT

WP: GFCI INSTALLED IN WEATHERPROOF ENCLOSURE

TR: TAMPER RESISTANT

TV: MOUNTED 6'-0" A.F.F.

IG: ISOLATED GROUND

U: PROVIDED W/ USB PORTS

xD: EXISTING TO BE DEMOLISHED xR: EXISTING TO BE REPLACED W/ NEW DEVICE

SPECIALTY RECEPTACLE, COORDINATE NEMA

CONFIGURATION W/ EQUIPMENT SERVED BY RECEPTACLE

WIREMOLD 880 SERIES 3 GANG STANDARD DEPTH FLOOR BOX.

PROVIDE DUPLEX RECEPTACLE IN TWO GANGS.

WIREMOLD 880 SERIES 2 GANG STANDARD DEPTH FLOOR BOX.

PROVIDE DUPLEX RECEPTACLE IN ONE GANG

J EQUIPMENT TERMINATION. VERIFY TERMINATION METHOD w/

MANUFACTURER

M MOTOR SWITCH

EQUIPMENT TERMINATION. VERIFY TERMINATION METHOD w/

MANUFACTURER

1.

2.

3.

4.

5.

6.

7.

TELE/DATA AND CATV CONDUIT IS SHOWN ON DRAWINGS ONLY

FOR SPECIFIC ROUTES OR SPECIAL CONDITIONS. ALL WALL

MOUNTED DEVICES ARE FINAL HEIGHT BY ARCHITECT.

CONDUIT AND TEL/DATA OR CATV CABLING WILL BE REQUIRED

AT ALL TELE/DATA AND CATV LOCATIONS ON THE DRAWINGS.

PROVIDE TELE/DATA AND CATV AS INDICATED. REVIEW DATA,

SWITCH, RECEPTACLE, ETC LOCATIONS AND HEIGHTS w/

OWNER PRIOR TO INSTALLATION.

RACEWAY SHALL BE INSTALLED FROM LOCATIONS INDICATED

ON DRAWINGS TO DEMARC LOCATION. COORDINATE FINAL

DEMARC LOCATIONS w/ TV AND TELEPHONE COMPANY.

VERIFY ALL FIELD CONDITIONS AND MEASUREMENTS PRIOR TO

BIDDING. COORDINATE ALL WORK w/ OTHER TRADES.

COORDINATE ALL CEILING MOUNTED DEVICES w/ ALL OTHER

TRADES PRIOR TO INSTALLATION.

PERFORM ALL WORK IN ACCORDANCE 2020 NEC.

COORDINATION OF FINAL FIXTURE LOCATION w/ OWNER AND

GENERAL CONTRACTOR PRIOR TO INSTALLATION OF CEILING.

FINAL COORDINATION OF SCOPE OF WORK, DIMENSIONS,

FIXTURE PLACEMENT, ROUTINGS, ETC. IS THE RESPONSIBILITY

OF THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS

PRIOR TO BIDDING.

COMMUNICATION NOTES

COMMUNICATION LEGEND

TELE/DATA LOCATION. PROVIDE SINGLE GANG

BOX w/ 1" CONDUIT TO ABOVE ACCESSIBLE

CEILING. 2XCAT6 CABLE TO DEMARC.

WIREMOLD 880 FLOOR BOX PROVIDED & INSTALLED BY E.C.

INSTALL 1" CONDUIT FROM FLOOR BOX UP WALL TO ABOVE

ACCESSIBLE CEILING. PROVIDE (2) CAT6 JACKS & 2XCAT6 TO

DEMARC

TV

TELE LOCATION. PROVIDE SINGLE GANG BOX w/ 1"

CONDUIT TO ABOVE ACCESSIBLE CEILING. 1XCAT6

CABLE TO DEMARC.

DATA LOCATION. PROVIDE SINGLE GANG BOX w/

1" CONDUIT TO ABOVE ACCESSIBLE CEILING.

1XCAT6 CABLE TO DEMARC.

CATV LOCATION. PROVIDE SINGLE GANG BOX w/

1" CONDUIT TO ABOVE ACCESSIBLE CEILING.

1XRG59 COAX CABLE TO DEMARC.

1P SINGLE POLE

1PH SINGLE-PHASE

2/C TWO-CONDUCTOR

2WAY TWO-WAY

3/C THREE-CONDUCTOR

3PH THREE-PHASE

3WAY THREE-WAY

4/C FOUR-WIRE

4PDT FOUR-POLE DOUBLE THROW

4PST FOUR-POLE SINGLE THROW

4WAY FOUR-WAY

4W FOUR-WIRE

ø PHASE --------------------A------------------------------------------------------------------------------------

A AMPERE

AC ALTERNATING CURRENT; ARMORED CABLE

ACT ACOUSTIC CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

A/E ARCHITECT/ENGINEER

AFC ABOVE FINISHED COUNTER

AFCI ARC FAULT CIRCUIT INTERUPTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE

AMP AMPERE

AMT AMOUNT

ANN ANNUNCIATOR

APPD APPROVED

APPROX APPROXIMATELY; APPROXIMATE

ARCH ARCHITECT

ASC ABOVE SUSPENDED CEILING; AMPS SHORT CIRCUIT

ATS AUTOMATIC TRANSFER SWITCH

ATTN ATTENTION

AUTO AUTOMATIC

AUX AUXILIARY

A/V AUDIO VISUAL

AVG AVERAGE

AWG AMERICAN WRE GAUGE

---------------B----------------------------------------------------------------------------------------

BAS BUILDING AUTOMATION SYSTEM

BAT BATTERY

BFF BELOW FINISHED FLOOR

BG BELOW GRADE

BKBD BACKBOARD

BLDG BUILDING

BLT BUILT

BLW BELOW

BOT BOTTOM

BPS BOLTED PRESSURE SWITCH

BRKR BREAKER

BSMT BASEMENT

BTWN BETWEEN

BX INTERLOCKED ARMORED CABLE

BYP BYPASS

---------------C---------------------------------------------------------------------------------------

C CELSIUS

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION SYSTEM

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TV

CD CANDELA; CONSTRUCTION DOCUMENTS;

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CIR CIRCLE

CKT CIRCUIT

C CENTERLINE

CL CURRENT LIMITING; CENTER LINE; CLASS; CLOSE

CLG CEILING

CLR CLEAR

CND CONDUIT

COAX COAXIAL

COL COLUMN

COMB COMBINATION; COMBINED

COMM COMMUNICATION

COMPR COMPRESSOR

CONC CONCRETE

CONN CONNECT

CORR CORRIDOR; CORRECT

CP CONTROL PANEL

CR CONTROL RELAY

CS CONTROL SWITCH

CT CURRENT TRANSFORMER

CTR CENTER

CTRL CONTROL

CU COPPER; COEFFICIENT OF UTILIZATION; CUBIC

CU FT CUBIC FEET

CUR CURRENT

---------------D----------------------------------------------------------------------

D DEPTH

DB DIRECT BURIAL / DECIBEL

DBL DOUBLE

DC DIRECT CURRENT

DDC DIRECT DIGITAL CONTROL

DEL DELETE; DELIVER

DEMO DEMOLITION; DEMONSTRATION

DEPT DEPARTMENT

DIA DIAMETER

DIAG DIAGRAM; DIAGONAL

DIFF DIFFERENCE

DIM DIMENSION

DISC DISCONNECT

DIST DISTANCE; DISTRICT

DISTR PNL DISTRIBUTION PANEL

DIV DIVISION; DIVIDE

DN DOWN

DOC DOCUMENT

DPDT DOUBLE POLE; DOUBLE THROW

DPST DOUBLE POLE; SINGLE THROW

DS DISCONNECT SWITCH

DWG DRAWING

----------------E----------------------------------------------------------------------

E EAST

EA EACH

EC ELECTRICAL CONTRACTOR

EL ELEVATION

ELEC ELECTRIC

ELEV ELEVATOR

ELR END OF LINE RESISTOR

EM EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

ENGR ENGINEER

ENGY ENERGY

ENT ELECTRICAL NONMETALLIC TUBING

ENTR ENTRANCE

EO ELECTRICAL OUTLET

EP ELECTRICAL PANEL

EQ EQUAL

EQUIP EQUIPMENT

EQUIV EQUIVALENT

EST ESTIMATE

ESTB ESTABLISH

EX EXISTING

EXH EXHAUST

EXP EXPANSION; EXPOSED; EXPAND

EXT EXTERIOR; EXTERNAL

EXTN EXTENSION

----------------F----------------------------------------------------------------------

F FAHRENHEIT; FEMALE

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FBO FURNISHED BY OWNER

FC FOOT-CANDLE

FCU FAN COIL UNIT

FDR FEEDER

FIN FINISH

FIN GR FINISH GRADE

FIXT FIXTURE

FL MT FLUSH MOUNT

FLEX FLEXIBLE

FLG FLOORING

FLR FLOOR

FLUOR FLUORESCENT

FM FREQUENCY MODULATION

FP FIREPROOF

FR FIRE RESISTANT

FREQ FREQUENCY

FS FUSIBLE SWITCH; FLOW SWITCH

FSC FOOD SERVICE EQUIPMENT CONTRACTOR

FT FEET; FIRE TREATED; FOOT

FU FUSE

FU SW FUSED SWITCH

FURN FURNISH; FURNACE; FURNITURE

FUT FUTURE

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

----------------G----------------------------------------------------------------------

GA GAUGE

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERAL; GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GFI GROUND FAULT INTERRUPTER

GOVT GOVERNMENT

GRN GROUND

GYP GYPSUM

----------------H----------------------------------------------------------------------

HDW HARDWARE

HF HIGH FREQUENCY

HID HIGH INTENSITY DISCHARGE

HO HOLD OPEN

HOA HAND-OFF-AUTOMATIC

HORIZ HORIZONTAL

HOSP HOSPITAL

HP HORSEPOWER; HEAT PUMP;

HIGH PRESSURE

HPS HIGH PRESSURE SODIUM

HT HEIGHT

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING AND AIR

CONDITIONING

HZ HERTZ; FREQUENCY IN CYCLES PER

SECOND

----------------I----------------------------------------------------------------------

ID INSIDE DIAMTER; INSIDE DIMENSION;

IDENTIFICATION

ILLUM ILLUMINATION

IMC INTERMEDIATE METAL CONDUIT

INFO INFORMATION

INSUL INSULATION

INTERCOM INTERCOMMUNICATION

INTL INTERNATIONAL

IR INFRARED; INSIDE RADIUS

IT INFORMATION TECHNOLOGY

----------------J----------------------------------------------------------------------

JB JUNCTION BOX

----------------K----------------------------------------------------------------------

KCMIL THOUSAND CIRCULAR MILS

KHz KILOHERTZ

KIT KITCHEN

KO KNOCKOUT

kV KILOVOLT kVA KILOVOLT AMPERES kVAh KILOVOLT AMPERE PER HOUR kVAR KILOVAR; KILOVOLT AMPERE

REACTIVE

kW KILOWAT kWh KILOWATT HOURS ----------------L----------------------------------------------------------------------

L LITER; ANGLE

LA LIGHTNING ARRESTER

LAN LOCAL AREA NETWORK

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LIN LINEAR

LM LUMEN

LOC LOCATION

LP LIGHT POLE; LOW PRESSURE

LPW LUMENS PER WATT

LT LIGHT

LT SW LIGHT SWITCH

LTD LIMITED

LTG LIGHTING

LV LOW VOLTAGE

----------------M----------------------------------------------------------------------

M METER

mA MILLIAMPERE

MACH MACHINE

MAG MAGNET

MAINT MAINTENANCE

MAN MANUAL

MATL MATERIAL

MAX MAXIMIM

MC MECHANICAL CONTRACTOR; METAL

CLAD CABLE

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MCM THOUSAND CIRCULAR MILS

MDP MAIN DISTRIBUTION PANEL

MDS MAIN DISTRIBUTION SWITCHBOARD

ME MECHANICAL ENGINEER

MECH MECHANICAL

MED MEDICAL; MEDIUM

MFD MANUFACTURED

MFR MANUFACTURER

MFR REC MANUFACTURER'S RECOMMENDATION

MH MANHOLE; METAL HALIDE

MHZ MEGAHERTZ

MI MINERAL INSULATED

MIC MICROPHONE

MID MIDDLE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MOA MULTIOUTLET ASSEMBLY

MOCP MAXIMUM OVERCURRENT PROTECTION

MOD MODIFY; MODULE

MON MONITOR

MOT MOTOR

MOV MOTOR OPERATED VALVE

MS MOTOR STARTER

MTD MOUNTED

MTG MEETING; MOUNTING

MTL METAL

MTS MANUAL TRANSFER SWITCH

MULT MULTIPLE

mV MILLIVOLT

MVA MEGAVOLT-AMPERE

MW MEGAWATT; MICROWAVE

mW MILLIWATT

MWH MEGAWATT HOUR

----------------N----------------------------------------------------------------------

N NORTH

NC NORMALLY CLOSED

NE NORMAL EMERGENCY

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NEUT NEUTRAL

NF NON-FUSED

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NFS NON-FUSED SWITCH

NIC NOT IN CONTRACT

NM NONMETALLIC

NMAG NONMAGNETIC

NO NORMALLY OPEN; NUMBER

NORM NORMAL

NTS NOT TO SCALE

----------------O----------------------------------------------------------------------

OA OVERALL; OUTSIDE AIR

OC ON CENTER

OCC OCCUPANCY

OCPD OVERCURRENT PROTECTION DEVICE

OD OUTSIDE DIAMETER; OUTSIDE DIMENSION

OF/CI OWNER FURNISHED / CONTRACTOR

INSTALLED

OF/OI OWNER FURNISHED / OWNER INSTALLED

OH OVERHEAD

OL OVERLOAD ELEMENT

OPP OPPOSITE

OPT OPTIONAL; OPTIMUM

OVC OVERCURRENT

----------------P----------------------------------------------------------------------

P POLE (S); PILOT

PA POWER AMPLIFIER; PUBLIC ADDRESS

PART PARTIAL

PB PULL BOX; PANEL BOARD; PANIC BAR;

PUSH-BUTTON

PC PLUMBING CONTRACTOR; PIECE

PE PHOTOELECTRIC, PNEUMATIC ELECTRIC

PEN PENETRATE

PERF PERFORATED

PERIM PERIMETER

PERM PERMANENT

PF POWER FACTOR

PH PHASE

PIV POST INDICATOR VALVE

PL PILOT LIGHT

PLBG PLUMBING

PNL PANEL

POS POSITION; POSITIVE

PP POWER POLE

PR PAIR

PRELIM PRELIMINARY

PREP PREPARATION

PRESS SW PRESSURE SWITCH

PREV PREVIOUS

PRI PRIMARY

PROJ PROJECT

PS PULL STATION

PT POTENTIAL TRANSFORMER

PVC POLYVINAL CHLORIDE (PLASTIC)

PWR POWER

----------------Q----------------------------------------------------------------------

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QTY QUANTITY

QUAL QUALITY

----------------R----------------------------------------------------------------------

R RELAY; RADIUS

R/W RIGHT OF WAY

RC REMOTE CONTROL

RCP REFLECTED CEILING PLAN

REC RECESSED

RCPT RECEPTACLE

REF REFRIGERATOR; REFERENCE

REINF REINFORCED

REPL REPLACE

REQD REQUIRED

REV REVISION; REVOLUTIONS

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RHC REHEAT COIL

ROW RIGHT OF WAY

RS RAPID START

RTG RATING

RTU ROOF TOP UNIT

----------------S----------------------------------------------------------------------

S/S START / STOP

SAMP SAMPLE

SCHED SCHEDULE

SCHEM SCHEMATIC

SD SMOKE DETECTOR

SDMPR SMOKE DAMPER

SEC SECONDARY

SECT SECTION

SEP SEPARATE

SHT SHEET

SIM SIMILAR

SLV SLEEVE

SMR SURFACE MOUNTED RACEWAY

SNSR SENSOR

SOLV SOLENOID VALVE

SPDT SINGLE POLE; DOUBLE THROW

SPEC SPECIFICATION

SPKR SPEAKER

SPLY SUPPLY

SPST SINGLE POLE; SINGLE THROW

SQ SQUARE

SS STAINLESS STEEL

ST SINGLE THROW; STAIRS; STREET

ST PR STATIC PRESSURE

STA STATION

STD STANDARD

STL STEEL

STOR STORAGE

STR STARTER; STRAIGHT; STRIKE; STRINGERS

STRB STROBE

STRB/HRN STROBE / HORN

STRUCT STRUCTURAL

SUB SUBSTITUTE

SUP SUPPLEMENTARY

SUPVR SUPERVISOR

SURF SURFACE

SUSP SUSPEND

SW SWITCH; SIDEWALK

SWBD SWITCHBOARD

SWGR SWITCHGEAR

SYM SYMBOL

SYS SYSTEM

----------------T----------------------------------------------------------------------

T&M TIME AND MATERIAL

TECH TECHNICAL

TEL TELEPHONE

TEMP TEMPORARY

TERM TERMINAL

THRU THROUGH

TL TWIST LOCK

TOC TOP OF CONCRETE; TOP OF CURB

TOL TOLERANCE

TP TWISTED PAIR; TELEPHONE POLE

TSP TWISTED SHIELDED PAIR

TSTAT THERMOSTAT

TV TELEVISION

TVOUT TELEVISION OUTLET

TYP TYPICAL

----------------U----------------------------------------------------------------------

UG UNDERGROUND

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

UP UTILITY POLE

UPS UNINTERRUPTIBLE POWER SUPPLY

UL UNDER WRITERS LABORATORIES

UTP UNSHIELDED TWITED PAIR

UTIL UTILITY

UV UNIT VENTILATOR; ULTRAVIOLET

----------------V----------------------------------------------------------------------

V VOLT

VA VOLT AMPERE

VAM VOLTAMMETER

VAR VARIATION; VARIES; VOLT AMPERE

REACTIVE

VD VOLTAGE DROP; VOLUME DAMPER

VERT VERTICAL

VF VARIABLE FREQUENCY

VFD VARIABLE FREQUENCY DRIVE

VID VIDEO

VIF VERIFY IN FIELD

VOLT VOLTAGE

VR VOLTAGE REGULATOR; VAPOR RETARDED

VRFY VERIFY

VRLY VOLTAGE RELAY

VS VOLTMETER SWITCH; VENT STACK

----------------W----------------------------------------------------------------------

W WIRE; WATT; WASTE; WEST; WIDE

W/ WITH

W/O WITHOUT

WHM WATTHOUR METER

WP WEATHERPROOF; WATER PUMP;

WATER HEATER

WR WEATHER RESISTANT; WATER REPELLENT

WW WIREWAY; WARM WHITE; WASTE WATER

----------------X----------------------------------------------------------------------

XFMR TRANSFORMER

XP EXPLOSION PROOF

FIRE ALARM LEGEND

M MANUAL PULL STATION

H HEAT DETECTOR

S SMOKE DETECTOR:

ER - ELEVATOR RECALL

DD - DUCT DETECTOR

LV - LINE VOLTAGE (120V)

HORN / STROBEF

STROBE LIGHTS

ADDRESSABLE MODULE:

FS - FLOW SWITCH

TS - TAMPER SWITCH

RT - REMOTE TEST

ST - SHUNT TRIP

PR - PRIMARY FLOOR RECALL

SR - SECONDARY FLOOR RECALL

FH - FIREMAN'S HAT

FL - FLASHING HAT

AIM - INPUT MODULE

AOM - OUTPUT MODULE

xx

FAAP

FIRE ALARM ANNUNCIATOR PANEL

PA OFFICE:

429 LAUREL RUN ROAD

CARMICHAELS, PA 15320

PH: (724) 966-5655

WV OFFICE:

54 WEST RUN RD.

MORGANTOWN, WV 26508

PH: (304) 291-2234

SHEET NAME:

MILLER ENGINEERING INC.

COPY RIGHT:

CHECKED BY:

DRAWN BY:

DESIGNED BY:

BCM

SEAL:

CONSULTANT:

PROJECT NAME:

PROJECT OWNER:

PROJECT STATUS:

PROJECT NUMBER:

ORIGINAL PAGE SIZE: 22x34

E000

ELECTRICAL

ABBREVIATIONS

12 OCT 2026

TRT

BCM

26010.1

ISSUED FOR

CONSTRUCTION

WVDNR

WVDNR CHIEF

LOGAN REC CENTER

POOL HVAC

RENOVATION

ELECTRICAL ABBREVIATIONS

N O

D

ES

C

R

IP

TI

O

N D

A

TE

DEMO POWER TO EXISTING UNITS AND MAKE SAFE

ANYTHING THAT REMAINS FOR RE-USE

PA OFFICE:

429 LAUREL RUN ROAD

CARMICHAELS, PA 15320

PH: (724) 966-5655

WV OFFICE:

54 WEST RUN RD.

MORGANTOWN, WV 26508

PH: (304) 291-2234

SHEET NAME:

MILLER ENGINEERING INC.

COPY RIGHT:

CHECKED BY:

DRAWN BY:

DESIGNED BY:

BCM

SEAL:

CONSULTANT:

PROJECT NAME:

PROJECT OWNER:

PROJECT STATUS:

PROJECT NUMBER:

ORIGINAL PAGE SIZE: 22x34

E001

ELECTRICAL DEMO

POWER PLAN

12 OCT 2026

TRT

BCM

26010.1

ISSUED FOR

CONSTRUCTION

WVDNR

WVDNR CHIEF

LOGAN REC CENTER

POOL HVAC

RENOVATION

N O

D

ES

C

R

IP

TI

O

N D

A

TE

1/8" = 1'-0"1

01 - DEMO ELECTRICAL POWER PLAN

GFCI

GFCI

G

FC

I G

FC

I

GFCI

GFCI

E101

L1

MDP

DPLN1

DPHN1

DPHN1

(NEW)-7,9,11

DPHN1

(NEW)-8,10,12

CH-1

AHU-1

DPHN1

(NEW)-20,22,24

DPHN1

(NEW)-19,21,23

ROUTE 4" EMT OVERHEAD WITH

COMPRESSION COUPLINGS FROM MDP TO

DPHN1, VERITY ROUTE PRIOR TO BIDDING

DPHN1 25, 27, 29

DPHN1 26, 28, 30

DPHN1

(NEW)-25,27,29

DPHN1

(NEW)-26,28,30

SW-1

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

WIRING IS SHOWN ON DRAWINGS ONLY FOR SPECIFIC ROUTES

OR SPECIAL CONDITIONS. ALL WALL MOUNTED DEVICES ARE

FINAL HEIGHT BY. ARCH.

WIRING AND CONDUIT OR MC CABLE SHALL BE REQUIRED FOR

ALL OUTLETS AND DEVICES. FOLLOW INDICATED CIRCUITS

NUMBERS AND PANEL DESIGNATION. OBTAIN PRIOR APPROVAL

OF ENGINEER FOR DEVIATIONS.

ALL 15A AND 20A, 115V AND 120V RECEPTACLES LOCATED IN

DWELLING UNITS SHALL BE TAMPER RESISTANT.

ALTHOUGH ALL BRANCH CIRCUIT WIRING IS NOT SHOWN, IT IS

THE INTENT OF THESE DOCUMENTS THAT A COMPLETE

BRANCH CIRCUIT WIRING SYSTEM BE INSTALLED.

ALL NEUTRALS SHALL BE FULL CAPACITY. THE USE OF SHARED

OR COMMON NEUTRALS IS PROHIBITED ON ALL ELECTRIC

WIRING.

PROVIDE CONTROL AND FIRE ALARM WIRE AS NECESSARY TO

INSTALL ALL SYSTEMS DEVICES AND PANELS FOR COMPLETE

SYSTEMS. FINAL CONNECTION TO PERMANTLY MOUNTED

EQUIPMENT IS PART OF THE ELECTRICAL SCOPE OF THIS

PROJECT.

PROVIDE TEL/DATA AND CAT5 AS INDICATED. REVIEW DATA,

SWITCH, RECEPTACLE, ETC LOCATIONS AND HEIGHTS WITH

OWNER PRIOR TO INSTALLATION.

ALL INTERIOR WIRING SHALL BE THHN/THWN IN METAL CONDUIT

OR MC CABLE. MAX OF 3'-0" OF FLEXIBLE CONDUIT MAY BE

USED FOR FINAL EQUIPMENT TERMINATIONS.

EXTERIOR WIRING IS TO BE THHN/THWN IN PVC CONDUIT. MAX.

OF 3'-0" OF FLEXIBLE METALLIC SEATITLE CONDUIT MAY BE

USED TO EXTERIOR EQUIPMENT.

TV AND TELEPHONE CABLING SHALL BE INSTALLED FROM

LOCATIONS INDICATED ON DRAWINGS TO DEMARC LOCATION.

COORDINATE FINAL DEMARC LOCATIONS w/ TV AND

TELEPHONE COMPANY.

GROUP AND TRAIN ALL TEL/DATA AND CABLE TV CABLE.

SUPPORT FROM STRUCTURE.

VERIFY ALL FIELD CONDITIONS AND MEASUREMENTS PRIOR TO

BIDDING. COORDINATE ALL WORK WITH OTHER TRADES.

COORDINATE ALL CEILING MOUNTED DEVICES WITH ALL OTHER

TRADES PRIOR TO INSTALLATION.

PERFORM ALL WORK IN ACCORDANCE WITH 2020 NEC.

COORDINATE FINAL FIXTURE LOCATIONS WITH OWNER AND

GENERAL CONTRACTOR PRIOR TO INSTALLATION OF CEILING.

FINAL COORDINATION OF SCOPE OF WORK , DIMENSIONS,

FIXTURE PLACEMENT, ROUTINGS, ETC IS THE RESPONSIBILITY

OF THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS

PRIOR TO BIDDING.

ELECTRICAL NOTES

DPHN1

DPLN1

DPHN1

(NEW)-1,3,5 DPHN1

(NEW)-2,4,6

DPLN1

(NEW)-1

DPLN1

(NEW)-2

DPLN1

(NEW)-3

BOILER E-STOP SWITCH

D

PL

N

(N

EW

)-7

D

PL

N

(N

EW

)-8

GLYCOL PUMP

VFD

PA OFFICE:

429 LAUREL RUN ROAD

CARMICHAELS, PA 15320

PH: (724) 966-5655

WV OFFICE:

54 WEST RUN RD.

MORGANTOWN, WV 26508

PH: (304) 291-2234

SHEET NAME:

MILLER ENGINEERING INC.

COPY RIGHT:

CHECKED BY:

DRAWN BY:

DESIGNED BY:

BCM

SEAL:

CONSULTANT:

PROJECT NAME:

PROJECT OWNER:

PROJECT STATUS:

PROJECT NUMBER:

ORIGINAL PAGE SIZE: 22x34

E101

ELECTRICAL POWER

PLAN

12 OCT 2026

TRT

BCM

26010.1

ISSUED FOR

CONSTRUCTION

WVDNR

WVDNR CHIEF

LOGAN REC CENTER

POOL HVAC

RENOVATION

N O

D

ES

C

R

IP

TI

O

N D

A

TE

1/8" = 1'-0"1

LEVEL 1 ELECTRICAL POWER PLAN

1/2" = 1'-0"2

LEVEL 1 ELECTRICAL POWER PLAN - ENLARGED

L3

DPHN1 DPLN1

E102

L3

DPHN1

DPLN1

SUBFEED PANEL "L3" TO DPLN1.

60A BREAKER, USE (4) #6 CU W/ #8 CU GRN.

1-1/2" CND

400-500 KCMIL cu W/ 1-#2 GR. CU, IN 4" EMT, WITH

COMPRESSION CONNECTORS. EXTEND TO MDP

AND INSTALL ON NEW 400A FEEDER BREAKER.

SEE SHEET E101 FOR LOCATION OF MDP

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

WIRING IS SHOWN ON DRAWINGS ONLY FOR SPECIFIC ROUTES

OR SPECIAL CONDITIONS. ALL WALL MOUNTED DEVICES ARE

FINAL HEIGHT BY. ARCH.

WIRING AND CONDUIT OR MC CABLE SHALL BE REQUIRED FOR

ALL OUTLETS AND DEVICES. FOLLOW INDICATED CIRCUITS

NUMBERS AND PANEL DESIGNATION. OBTAIN PRIOR APPROVAL

OF ENGINEER FOR DEVIATIONS.

ALL 15A AND 20A, 115V AND 120V RECEPTACLES LOCATED IN

DWELLING UNITS SHALL BE TAMPER RESISTANT.

ALTHOUGH ALL BRANCH CIRCUIT WIRING IS NOT SHOWN, IT IS

THE INTENT OF THESE DOCUMENTS THAT A COMPLETE

BRANCH CIRCUIT WIRING SYSTEM BE INSTALLED.

ALL NEUTRALS SHALL BE FULL CAPACITY. THE USE OF SHARED

OR COMMON NEUTRALS IS PROHIBITED ON ALL ELECTRIC

WIRING.

PROVIDE CONTROL AND FIRE ALARM WIRE AS NECESSARY TO

INSTALL ALL SYSTEMS DEVICES AND PANELS FOR COMPLETE

SYSTEMS. FINAL CONNECTION TO PERMANTLY MOUNTED

EQUIPMENT IS PART OF THE ELECTRICAL SCOPE OF THIS

PROJECT.

PROVIDE TEL/DATA AND CAT5 AS INDICATED. REVIEW DATA,

SWITCH, RECEPTACLE, ETC LOCATIONS AND HEIGHTS WITH

OWNER PRIOR TO INSTALLATION.

ALL INTERIOR WIRING SHALL BE THHN/THWN IN METAL CONDUIT

OR MC CABLE. MAX OF 3'-0" OF FLEXIBLE CONDUIT MAY BE

USED FOR FINAL EQUIPMENT TERMINATIONS.

EXTERIOR WIRING IS TO BE THHN/THWN IN PVC CONDUIT. MAX.

OF 3'-0" OF FLEXIBLE METALLIC SEATITLE CONDUIT MAY BE

USED TO EXTERIOR EQUIPMENT.

TV AND TELEPHONE CABLING SHALL BE INSTALLED FROM

LOCATIONS INDICATED ON DRAWINGS TO DEMARC LOCATION.

COORDINATE FINAL DEMARC LOCATIONS w/ TV AND

TELEPHONE COMPANY.

GROUP AND TRAIN ALL TEL/DATA AND CABLE TV CABLE.

SUPPORT FROM STRUCTURE.

VERIFY ALL FIELD CONDITIONS AND MEASUREMENTS PRIOR TO

BIDDING. COORDINATE ALL WORK WITH OTHER TRADES.

COORDINATE ALL CEILING MOUNTED DEVICES WITH ALL OTHER

TRADES PRIOR TO INSTALLATION.

PERFORM ALL WORK IN ACCORDANCE WITH 2020 NEC.

COORDINATE FINAL FIXTURE LOCATIONS WITH OWNER AND

GENERAL CONTRACTOR PRIOR TO INSTALLATION OF CEILING.

FINAL COORDINATION OF SCOPE OF WORK , DIMENSIONS,

FIXTURE PLACEMENT, ROUTINGS, ETC IS THE RESPONSIBILITY

OF THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS

PRIOR TO BIDDING.

ELECTRICAL NOTES

PA OFFICE:

429 LAUREL RUN ROAD

CARMICHAELS, PA 15320

PH: (724) 966-5655

WV OFFICE:

54 WEST RUN RD.

MORGANTOWN, WV 26508

PH: (304) 291-2234

SHEET NAME:

MILLER ENGINEERING INC.

COPY RIGHT:

CHECKED BY:

DRAWN BY:

DESIGNED BY:

BCM

SEAL:

CONSULTANT:

PROJECT NAME:

PROJECT OWNER:

PROJECT STATUS:

PROJECT NUMBER:

ORIGINAL PAGE SIZE: 22x34

E102

ELECTRICAL POWER

PLAN

12 OCT 2026

TRT

BCM

26010.1

ISSUED FOR

CONSTRUCTION

WVDNR

WVDNR CHIEF

LOGAN REC CENTER

POOL HVAC

RENOVATION

N O

D

ES

C

R

IP

TI

O

N D

A

TE

1/8" = 1'-0"1

LEVEL 2 ELECTRICAL POWER PLAN

3/8" = 1'-0"2

LEVEL 2 ELECTRICAL POWER PLAN - ENLARGED

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

WIRING IS SHOWN ON DRAWINGS ONLY FOR SPECIFIC ROUTES

OR SPECIAL CONDITIONS. ALL WALL MOUNTED DEVICES ARE

FINAL HEIGHT BY. ARCH.

WIRING AND CONDUIT OR MC CABLE SHALL BE REQUIRED FOR

ALL OUTLETS AND DEVICES. FOLLOW INDICATED CIRCUITS

NUMBERS AND PANEL DESIGNATION. OBTAIN PRIOR APPROVAL

OF ENGINEER FOR DEVIATIONS.

ALL 15A AND 20A, 115V AND 120V RECEPTACLES LOCATED IN

DWELLING UNITS SHALL BE TAMPER RESISTANT.

ALTHOUGH ALL BRANCH CIRCUIT WIRING IS NOT SHOWN, IT IS

THE INTENT OF THESE DOCUMENTS THAT A COMPLETE

BRANCH CIRCUIT WIRING SYSTEM BE INSTALLED.

ALL NEUTRALS SHALL BE FULL CAPACITY. THE USE OF SHARED

OR COMMON NEUTRALS IS PROHIBITED ON ALL ELECTRIC

WIRING.

PROVIDE CONTROL AND FIRE ALARM WIRE AS NECESSARY TO

INSTALL ALL SYSTEMS DEVICES AND PANELS FOR COMPLETE

SYSTEMS. FINAL CONNECTION TO PERMANTLY MOUNTED

EQUIPMENT IS PART OF THE ELECTRICAL SCOPE OF THIS

PROJECT.

PROVIDE TEL/DATA AND CAT5 AS INDICATED. REVIEW DATA,

SWITCH, RECEPTACLE, ETC LOCATIONS AND HEIGHTS WITH

OWNER PRIOR TO INSTALLATION.

ALL INTERIOR WIRING SHALL BE THHN/THWN IN METAL CONDUIT

OR MC CABLE. MAX OF 3'-0" OF FLEXIBLE CONDUIT MAY BE

USED FOR FINAL EQUIPMENT TERMINATIONS.

EXTERIOR WIRING IS TO BE THHN/THWN IN PVC CONDUIT. MAX.

OF 3'-0" OF FLEXIBLE METALLIC SEATITLE CONDUIT MAY BE

USED TO EXTERIOR EQUIPMENT.

TV AND TELEPHONE CABLING SHALL BE INSTALLED FROM

LOCATIONS INDICATED ON DRAWINGS TO DEMARC LOCATION.

COORDINATE FINAL DEMARC LOCATIONS w/ TV AND

TELEPHONE COMPANY.

GROUP AND TRAIN ALL TEL/DATA AND CABLE TV CABLE.

SUPPORT FROM STRUCTURE.

VERIFY ALL FIELD CONDITIONS AND MEASUREMENTS PRIOR TO

BIDDING. COORDINATE ALL WORK WITH OTHER TRADES.

COORDINATE ALL CEILING MOUNTED DEVICES WITH ALL OTHER

TRADES PRIOR TO INSTALLATION.

PERFORM ALL WORK IN ACCORDANCE WITH 2020 NEC.

COORDINATE FINAL FIXTURE LOCATIONS WITH OWNER AND

GENERAL CONTRACTOR PRIOR TO INSTALLATION OF CEILING.

FINAL COORDINATION OF SCOPE OF WORK , DIMENSIONS,

FIXTURE PLACEMENT, ROUTINGS, ETC IS THE RESPONSIBILITY

OF THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS

PRIOR TO BIDDING.

ELECTRICAL NOTES

F1 F1 F1

DPLN1

(NEW)-9

E103

F2 F2 F2

F1 F1 F1 E1

PA OFFICE:

429 LAUREL RUN ROAD

CARMICHAELS, PA 15320

PH: (724) 966-5655

WV OFFICE:

54 WEST RUN RD.

MORGANTOWN, WV 26508

PH: (304) 291-2234

SHEET NAME:

MILLER ENGINEERING INC.

COPY RIGHT:

CHECKED BY:

DRAWN BY:

DESIGNED BY:

BCM

SEAL:

CONSULTANT:

PROJECT NAME:

PROJECT OWNER:

PROJECT STATUS:

PROJECT NUMBER:

ORIGINAL PAGE SIZE: 22x34

E103

ELECTRICAL

LIGHTING PLAN

12 OCT 2026

TRT

BCM

26010.1

ISSUED FOR

CONSTRUCTION

WVDNR

WVDNR CHIEF

LOGAN REC CENTER

POOL HVAC

RENOVATION

N O

D

ES

C

R

IP

TI

O

N D

A

TE

1/4" = 1'-0"1

LEVEL 1 ELECTRICAL LIGHTING PLAN

1/2" = 1'-0"2

ENLARGED LEVEL 1 ELECTRICAL LIGHTING PLAN

PA OFFICE:

CARMICHAELS, PA 15320

PH: (724) 966-5655

WV OFFICE:

54 WEST RUN RD.

MORGANTOWN, WV 26508

PH: (304) 291-2234

SHEET NAME:

MILLER ENGINEERING INC.

COPY RIGHT:

CHECKED BY:

DRAWN BY:

DESIGNED BY:

BCM

SEAL:

CONSULTANT:

PROJECT NAME:

PROJECT OWNER:

PROJECT STATUS:

PROJECT NUMBER:

ORIGINAL PAGE SIZE: 22x34

E601

ELECTRICAL

SCHEDULES &

DETAILS

12 OCT 2026

TRT

BCM

26010.1

ISSUED FOR

CONSTRUCTION

WVDNR

WVDNR CHIEF

LOGAN REC CENTER

POOL HVAC

RENOVATION

N O

D

ES

C

R

IP

TI

O

N D

A

TE

Notes:

DPLN1 (NEW)-29 DPLN1 (NEW)-30

DPLN1 (NEW)-27 DPLN1 (NEW)-28

DPLN1 (NEW)-25 DPLN1 (NEW)-26

DPLN1 (NEW)-23 DPLN1 (NEW)-24

DPLN1 (NEW)-21 DPLN1 (NEW)-22

DPLN1 (NEW)-19 DPLN1 (NEW)-20

DPLN1 (NEW)-17 DPLN1 (NEW)-18

DPLN1 (NEW)-15 DPLN1 (NEW)-16

DPLN1 (NEW)-13 DPLN1 (NEW)-14

DPLN1 (NEW)-11 DPLN1 (NEW)-12

DPLN1 (NEW)-9 LTG BOILER ROOM 20 A 1 ... DPLN1 (NEW)-10

DPLN1 (NEW)-7 CONVENIENCE RCP BOILER... 20 A 1 ... 1 20 A RCP POOL SIDE DPLN1 (NEW)-8

DPLN1 (NEW)-5 SPARE 20 A 1 ... 1 20 A SPARE DPLN1 (NEW)-6

DPLN1 (NEW)-3 B-3 20 A 1 ... 1 20 A SPARE DPLN1 (NEW)-4

DPLN1 (NEW)-1 B-1 20 A 1 ... 1 20 A B-2 DPLN1 (NEW)-2

CKTCKT Circuit DescriptionCircuit Description TripTrip PolesPoles PolesPoles TripTrip Circuit DescriptionCircuit Description CKTCKT

ENCLOSURE:ENCLOSURE: NEMA 1 Indoor MAIN TYPE:MAIN TYPE: MLO

WIRES:WIRES: 4 MAIN:MAIN: 60 A

VOLTS:VOLTS: 120/208 Wye PHASES:PHASES: 3

Branch Panel:Branch Panel: DPLN1 (NEW)DPLN1 (NEW)

Notes:

41 SPARE 20 A 1 ... 42

39 SPARE 20 A 1 ... 40

37 SPARE 20 A 1 ...

3 60 A SUBFEED DPLN1

35 ... 1 20 A SPARE 36

33 - 20 A 2 ... 1 20 A SPARE 34

31 SPARE 20 A 1 ... 1 20 A SPARE 32

29 CEILING FANS #7,#8 20 A 1 ... 30

27 TV YOGA 20 A 1 ... 2 20 A - 28

25 CEILING FANS #3,#4 20 A 1 ... 1 20 A - 26

23 LOBBY FANS #1,#2 20 A 1 ... 1 20 A TREADMILL 24

21 - 20 A 1 ... 1 20 A TREADMILL 22

19 - 20 A 1 ... 1 20 A BATHROOM EXHAUST FAN 20

17 - 20 A 1 ... 18

15 YOGA ROOM LTG 20 A 1 ... 16

13 TV RCP 20 A 1 ...

3 20 A DH-2

11 EXERCISE RM RCP 20 A 1 ... 1 20 A EXERCISE RM RCP 12

9 EXERCISE RM RCP 20 A 1 ... 1 20 A EXERCISE RM RCP 10

7 SPARE 20 A 1 ... 1 20 A FANS YOGA 8

5 EXERCISE EQUIPMENT - TREAD 20 A 1 ... 1 20 A SPIN ROOM TV/FANS 6

3 EXERCISE EQUIPMENT 20 A 1 ... 1 20 A EXERCISE EQUIPMENT 4

1 EXERCISE EQUIPMENT 20 A 1 ... 1 20 A EXERCISE EQUIPMENT... 2

CKTCKT Circuit DescriptionCircuit Description TripTrip PolesPoles PolesPoles TripTrip Circuit DescriptionCircuit Description CKTCKT

ENCLOSURE:ENCLOSURE: NEMA 1 Indoor MAIN TYPE:MAIN TYPE: MLO

WIRES:WIRES: 4 MAIN:MAIN: 100 A

VOLTS:VOLTS: 120/208 Wye PHASES:PHASES: 3

Branch Panel:Branch Panel: L3(EXIST.)L3(EXIST.)

Notes:

59 60 57 58 55 56 53 54 51 52 49 50 47 ... 48 45 ... 46

SCOUR BLOWER 15 A 3

3 60 A SPARE

41 ... 42 39 ... 40

ASR PUMP 15 A 3

3 40 A RECIRC PUMP

35 ... 36 33 ... 34

ELEVATOR DISCONNECT SWITCH 60 A 3

3 400 A NEW SUBFEED DPHN1

29 ... 30 27 ... 28

HVAC UNIT PU-3 40 A 3

3 90 A L4 SUBFEED

23 ... 24 21 ... 22

HVAC UNIT PU-1 90 A 3

3 90 A HVAC UNIT PU-2

17 ... 18 15 ... 16

PANEL H2 100 A 3

3 40 A DUCT HEATER

11 ... 12 9 ... 10

SEWAGE LIFT STATION 70 A 3

3 150 A PANEL H1

5 ... 6 3 ... 4

L1 SUBFEED 90 A 3

3 90 A L2 SUBFEED

CKTCKT Circuit DescriptionCircuit Description TripTrip PolesPoles

AA BB CC

PolesPoles TripTrip Circuit DescriptionCircuit Description CKTCKT

ENCLOSURE:ENCLOSURE: NEMA 1 Indoor MAIN TYPE:MAIN TYPE: MCB

WIRES:WIRES: 4 MAIN:MAIN: 1200 A

VOLTS:VOLTS: 480/277 Wye PHASES:PHASES: 3

Branch Panel:Branch Panel: MDP(EXIST.)MDP(EXIST.)

DISCONNECT SWITCH SCHEDULE

TAG SERVES POLES VOLTS

RATING

NEMA ENCLOSURE TYPE

SWITCH FUSE

SW-1 EF-1 AND EF-2 3 480 V 30 A 15 A TYPE3R Fusible

LIGHT FIXTURE SCHEDULE

TAG MFR MODEL LUMENS COLOR TEMP VOLTS WATTS DESCRIPTION

F1 LITHONIA ZL1D L48 3000LM FST MVOLT 3500K 80CRI 4,456 3,500 K UNV 30 W 4' LED STRIP LIGHT F2 5,500 4,000 K 70 W

VARIABLE FREQUENCY DRIVE SCHEDULE

TAG SERVES POLES VOLTS ENCLOSURE STARTER SIZE MOTOR HP DESCRIPTION

VFD-1 EF-1 3 208 NEMA 1 Indoor 0 2 HVAC RATED VFD WITH INTEGRAL DISCONNECT AND DIGITAL OVERLOAD VFD-2 EF-2 3 208 NEMA 1 Indoor 0 2 HVAC RATED VFD WITH INTEGRAL DISCONNECT AND DIGITAL OVERLOAD

Notes:

DPHN1 (NEW)-35 DPHN1 (NEW)-36

DPHN1 (NEW)-33 DPHN1 (NEW)-34

DPHN1 (NEW)-31 DPHN1 (NEW)-32

DPHN1 (NEW)-29 ... DPHN1 (NEW)-30

DPHN1 (NEW)-27 ... DPHN1 (NEW)-28

DPHN1 (NEW)-25

P-8 15 A 3

3 15 A P-9

DPHN1 (NEW)-26

DPHN1 (NEW)-23 ... DPHN1 (NEW)-24

DPHN1 (NEW)-21 ... DPHN1 (NEW)-22

DPHN1 (NEW)-19

EF-1 15 A 3

3 15 A EF-2

DPHN1 (NEW)-20

DPHN1 (NEW)-17 ... DPHN1 (NEW)-18

DPHN1 (NEW)-15 ... DPHN1 (NEW)-16

DPHN1 (NEW)-13

P-6 15 A 3

3 15 A P-7

DPHN1 (NEW)-14

DPHN1 (NEW)-11 ... DPHN1 (NEW)-12

DPHN1 (NEW)-9 ... DPHN1 (NEW)-10

DPHN1 (NEW)-7

AHU-1 60 A 3

3 150 A CH-1

DPHN1 (NEW)-8

DPHN1 (NEW)-5 ... DPHN1 (NEW)-6

DPHN1 (NEW)-3 ... DPHN1 (NEW)-4

DPHN1 (NEW)-1

P-4 15 A 3

3 15 A P-5

DPHN1 (NEW)-2

CKTCKT Circuit DescriptionCircuit Description TripTrip PolesPoles PolesPoles TripTrip Circuit DescriptionCircuit Description CKTCKT

ENCLOSURE:ENCLOSURE: NEMA 1 Indoor MAIN TYPE:MAIN TYPE: MCB

WIRES:WIRES: 4 MAIN:MAIN: 400 A

VOLTS:VOLTS: 480/277 Wye PHASES:PHASES: 3

Branch Panel:Branch Panel: DPHN1 (NEW)DPHN1 (NEW)

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL

LABOR REQUIRED TO INSTALL, COMPLETE, AND OPERATE AS

INDICATED ON THE DRAWINGS, SPECIFICATIONS, AND

REQUIRED BY CODE.

SEPARATE BALANCE DAMPERS WILL BE INSTALLED AT ALL

TAKE-OFFS FROM MAIN DUCTS. FIRE DAMPERS WILL BE

INSTALLED AT LOCATIONS SHOWN OR WHERE ANY DUCT

PENETRATES A FIRE RATED WALL. REFER TO ARCHITECTURAL

SHEETS FOR RATED WALLS. FIRE DAMPERS ARE TO MATCH THE

RATING OF THE WALL OR CEILING BEING PENETRATED.

ALL DUCT TAKE-OFFS AND TRANSITIONS WILL BE TAPERED.

ELBOWS AND TURNS SHALL BE CONSTRUCTED w/ A SMOOTH

RADIUSED FITTING MIN 1.5 TIMES THE WIDTH OF THE DUCT.

TURNING VANES ARE NOT PERMITTED, UNLESS APPROVED BY

ENGINEER OR INDICATED ON DRAWINGS.

CERTAIN ITEMS SUCH AS RISERS AND DROPS IN DUCTWORK,

ACCESS DOORS, VOLUME DAMPERS, ETC. ARE INDICATED ON

THE CONTRACT DOCUMENT DRAWINGS FOR CLARITY FOR A

SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE

INTERPRETED AS THE EXTENT OF THE REQUIREMENTS FOR

THOSE ITEMS.

ALL DUCTWORK IS TO BE EXTERNALLY INSULATED. INTERIOR

MOUNTED DUCTWORK SHALL HAVE FOIL FACED 1-1/2 TO 2"

FIBERGLASS INSULATION AND SEALED w/ FIBERGLASS

REINFORCED FOIL TAPE.

CONSTRUCT ALL DUCTWORK PER SMACNA STANDARDS FOR

LOW PRESSURE DUCTWORK (2.0" STATIC). ALL JOINTS ARE TO

BE SEALED w/ MASTIC.

PROVIDE AIR LOUVERS w/ GRAVITY BACKDRAFT DAMPERS. ALL

EXTERIOR LOUVERS WILL HAVE 60% MIN. OPEN AREA AND BUG

SCREENS. INSTALL ALL w/ BIRD SCREEN. COLORS BY OWNER/ARCHITECT. COORDINATE LOCATIONS w/ GENERAL

CONTRACTOR.

PROVIDE FULLY ADHERED VELOCITY DUCT LINER FROM UNIT

DISCHARGE AND RETURN TO 10'-0" BEYOND UNIT. PROVIDE

NOSING AT THE BEGINNING AND END OF THE DUCT LINER.

UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM

THERMOSTATS AND HUMIDISTATS AT 5'-0" ABOVE FINISHED

FLOOR. FINAL THERMOSTAT LOCATION BY OWNER/ARCHITECT.

ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS.

ALL DUCTWORK DIMENSIONS, AS SHOWN ON THE DRAWINGS,

ARE INTERNAL CLEAR DIMENSIONS AND DUCT SIZE SHALL BE

INCREASED TO COMPENSATE FOR DUCT LINING WHERE

APPLICABLE.

COORDINATE DIFFUSERS, REGISTER, AND GRILLE LOCATIONS

w/ ARCHITECTURAL REFLECTED CEILING PLANS, LIGHTING, AND

OTHER CEILING ITEMS. MAKE MINOR DUCT MODIFICATIONS TO

SUIT.

LOCATE ALL MECHANICAL EQUIPMENT FOR UN-OBSTRUCTED

ACCESS TO UNIT ACCESS PANELS, CONTROL, AND VALVING.

PROVIDE FLEXIBLE CONNECTIONS IN ALL DUCTWORK SYSTEMS

CONNECTED TO AIR HANDLING UNITS, FANS, AND OTHER

EQUIPMENT WHICH REQUIRE VIBRATION ISOLATION.

OTHERWISE NOTED, ALL DUCTWORK IS OVERHEAD, TIGHT TO

THE UNDERSIDE OF THE STRUCTURAL, WITH SPACE FOR

INSULATION.

RUNS OF FLEXIBLE DUCT SHALL NOT EXCEED 3'-0". FLEXIBLE

DUCT IS TO BE USED FOR FINAL CONNECTIONS TO GRILLES

AND DIFFUSER ONLY.

ALL DUCTWORK SHALL BE COORDINATED w/ ALL TRADES

INVOLVED. OFFSETS IN DUCTS, INCLUDING DIVIDED DUCTS AND

TRANSITIONS AROUND OBSTRUCTIONS, SHALL BE PROVIDED AT

NO ADDITIONAL COST TO THE OWNER.

PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS

FOR ALL SMOKE DETECTORS, FIRE DAMPERS, SMOKE

DAMPERS, HUMIDIFIERS, COILS AND OTHER ITEMS LOCATED IN

DUCTWORK WHICH REQUIRE SERVICE OR INSPECTION.

SEE SPEC FOR DUCTWORK GAUGES, BRACING, HANGERS, AND

OTHER REQUIREMENTS.

EXTERIOR LOUVERS ARE INDICATED FOR INFORMATION ONLY.

DETAILED DESCRIPTIONS ARE PROVIDED IN THE

ARCHITECTURAL SPECIFICATIONS. LOUVER SIZES, LOCATIONS,

MOUNTING, AND DETAILS SHALL BE COORDINATED w/ OTHER

TRADES INVOLVED.

PERFORM WORK IN ACCORDANCE w/ CURRENT INTERNATIONAL

MECHANICAL CODE, FUEL GAS CODE, ASHRAE, SMACNA, STATE,

AND LOCAL CODES AND REQUIREMENTS.

VERIFY ALL FIELD CONDITIONS AND MEASUREMENTS PRIOR TO

BIDDING. COORDINATE ALL WORK w/ OTHER TRADES.

COORDINATE ALL CEILING MOUNTED DEVICES w/ ALL OTHER

TRADES PRIOR TO INSTALLATION. FINAL COORDINATION OF

SCOPE OF WORK, DIMENSIONS, FIXTURE PLACEMENT, ROUTING

ETC. IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR

AND ALL SUB-CONTRACTORS PRIOR TO BIDDING.

MECHANICAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL

LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE

PIPING SYSTEMS AS INDICATED ON THE DRAWINGS,

SPECIFICATIONS, AND REQUIRED BY CODE.

MAINTAIN A MIN. OF 3'-0" OF GROUND COVER OVER ALL

UNDERGROUND HAVC PIPING, UNLESS OTHERWISE NOTED.

NATURAL GAS / LP PIPING IS TO BE P40 STEEL w/ BLACK IRON

THREADED OR MECHANICALLY PRESSED FITTINGS.

MECHANICALLY PRESSED FITTINGS MUST BE LISTED FOR

NATURAL GAS OR LP PIPING. PROVIDE WELDED GAS PIPING BY

SIZE AS REQUIRED BY FUEL GAS CODE.

PROVIDE BALL VALVE STOPS AT ALL FIXTURES. PROVIDE

UNIONS, DIRT LEGS, AND REGULATORS ON ALL EQUIPMENT.

INSTALL APPLIANCE REGLUALTORS ON ALL NATURAL GAS / LP

EQUIPMENT. VENT REGULATORS PER THE FUEL GAS CODE &

REGULATOR MFR'S REQUIREMENTS.

COORDINATE ALL STUB-UPS AND FIELD ADJUST LOCATIONS FOR

COORDINATION AS NECESSARY. AVOID EXCESSIVE ADDITIONAL

PIPE FITTINGS.

PROVIDE AN AIR VENT AT THE HIGH POINT OF EACH DROP IN

THE HEATING WATER, CHILLED WATER, AND OTHER CLOSED

WATER PIPING SYSTEMS. ALL PIPING SHALL GRADE TO LOW

POINTS. PROVIDE HOSE END DRAIN VALVES AT BOTTOM OF

RISERS AND LOW POINTS.

UNLESS OTHERWISE NOTED, ALL PIPING IS TO OVERHEAD,

TIGHT TO UNDERSIDE OF STRUCTURE OR DECK w/ SPACE FOR

INSULATION.

INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS,

TRAPS, FLANGES, ETC. ARE ACCESSIBLE.

ALL BALANCING VALVES AND BUTTERFLY VALVES SHALL BE

PROVIDED w/ POSITION INDICATORS AND MANUAL ADJUSTABLE

STOPS.

ALL VALVES (EXCEPT CONTROL VALVES) AND STRAINERS SHALL

BE FULL SIZE OF PIPE BEFORE REDUCING SIZE TO MAKE

CONNECTIONS TO EQUIPMENT AND CONTROLS.

UNIONS AND/OR FLANGES SHALL BE INSTALLED AT EACH PIECE

OF EQUIPMENT, IN BYPASSES, AND IN LONG PIPING RUNS O

PERMIT DISASSEMBLY FOR ALTERATIONS AND REPAIRS.

ALL PIPING SHALL CLEAR DOORS AND WINDOWS. ALL VALVES

SHALL BE ADJUSTED FOR SMOOTH AND EASY OPERATION.

ALL PIPING WORK SHALL BE COORDINATED w/ ALL TRADES

INVOLVED. OFFSETS IN PIPING AROUND OBSTRUCTIONS SHALL

BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER.

PROVIDE FLEXIBLE CONNECTIONS IN ALL PIPING SYSTEMS

CONNECTED TO PUMPS, CHILLERS, COOLING TOWERS, AND

OTHER EQUIPMENT WHICH REQUIRE VIBRATION ISOLATION

EXCEPT WATER COILS.

ALL WORK TO MEET REQUIREMENTS OF CURRENT

INTERNATIONAL PLUMBING CODE, INTERNATIONAL MECHANICAL

CODE, APPLICABLE LOCAL CODES, LOCAL UTILITY

REQUIREMENTS, AND THE INTERNATIONAL FUEL GAS CODE.

FINAL COORDINATION OF SCOPE OF WORK, DIMENSIONS,

FIXTURE PLACEMENT, ROUTING, ECT. IS THE RESPONSIBILITY OF

THE PRIME CONTRACTOR AND ALL SUB-CONTRACTORS PRIOR

TO BIDDING.

PIPING NOTES

--------------------SYMBOLS------------------------------------------------------------------------

# NUMBER

& AND

º DEGREES

ºF DEGREES FAHRENHEIT

--------------------A------------------------------------------------------------------------------------

AAV AUTOMATIC AIR VENT

ABV ABOVE

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATELY

AUX AUXILIARY

AVG AVERAGE

---------------B----------------------------------------------------------------------------------------

BFV BUTTERFLY VALVE

BH BASEBOARD HEATER

BHP BRAKE HORESPOWER

BLR BOILER

BTUH BRITISH THERMAL UNIT PER HOUR

BV BALL VALVE

---------------C---------------------------------------------------------------------------------------

CA COMPRESSED AIR

CAP CAPACITY

CFM CUBIC FEET PER MINUTE

CHKV CHECK VALVE

CIRC CIRCULATING

CI CAST IRON

CKT CIRCUIT

CMU CONCRETE MASONARY UNIT

C/O CLEAN OUT

CON CONDENSATE

CONT CONTINUATION

CT COOLING TOWER

CU CONDENSING UNIT

---------------D----------------------------------------------------------------------

DIA DIAMETER

DWG DRAWING

DWH DOMESTIC WATER HEATER

----------------E----------------------------------------------------------------------

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE(ºF)

EC ELECTRICAL CONTRACTOR

EF EXHAUST FAN

EFF EFFICIENCY

ELEC ELECTRIC

ELEV ELEVATION

EQUIP EQUIPMENT

ESP EXTERNAL STATIC PRESSURE

EXH EXHAUST

EXIST EXISTING

EWT ENTERING WATER TEMPERATUR(ºF)

----------------F----------------------------------------------------------------------

ºF FAHRENHEIT

FCU FAN COIL UNIT

FD FIRE DAMPER/FLOOR DRAIN

FLA FULL LOAD AMPS

FLR FLOOR

FO FLAT OVAL

FPM FEET PER MINUTE

FPS FEET PER SECOND

FT FEET

----------------G----------------------------------------------------------------------

GAS NATURAL GAS

GALV GALVANIZED

GA GAUGE

GC GENERAL CONTRACTOR

GLV GLOBE VALVE

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GV GATE VALVE

----------------H----------------------------------------------------------------------

HCWL HYDRONIC CHILLED WATER LOOP

HCWR HYDRONIC CHILLED WATER RETURN

HCWS HYDRONIC CHILLED WATER SUPPLY

HHWL HYDRONIC HOT WATER LOOP

HHWR HYDRONIC HOT WATER RETURN

HHWS HYDRONIC HOT WATER SUPPLY

HORIZ HORIZONTAL

HP HORSEPOWER/HEAT PUMP

HR HOUR

HTG HEATING

HVAC HEATING, VENTILATING, AND AIR CONDITIONING

HZ HERTZ

----------------I----------------------------------------------------------------------

ID INSIDE DIAMETER

IN INCHES

INV INVERT

----------------J----------------------------------------------------------------------

JB JUNCTION BOX

----------------K----------------------------------------------------------------------

KW KILOWATT

KWH KILOWATT HOUR

----------------L----------------------------------------------------------------------

LAT LEAVING AIR TEMPERATURE(ºF)

LBS POUNDS

LBS/HR POUNDS PER HOUR

LF LINEAR FEET

LP LIQUID PROPANE

LV LOUVER

LVG LEAVING

LWT LEAVING WATER TEMPERATURE(ºF)

----------------M----------------------------------------------------------------------

MAU MAKE-UP AIR UNIT

MAV MANUAL AIR VENT

MAX MAXIUM

MBH THOUSAND BTUH

MC MECHANICAL CONTRACTOR

MCC MOTOR CONTROL CENTER

MECH MECHANICAL

MFG MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MS MINI-SPLIT SYSTEM

----------------N----------------------------------------------------------------------

N/A NOT APPLICABLE

NC NORMALLY CLOSED; NOISE CRITERIA

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NO NORMALLY OPEN

NTS NOT TO SCALE

----------------O----------------------------------------------------------------------

OA OUTSIDE AIR

OC ON CENTER

OCC OCCUPANCY

OD OUTSIDE DIAMETER

OSHA OCCUPATIONAL SAFETY AND HEALTH

ADMINISTRATION

OSV OIL SAFETY VALVE

OZ OUNCE

----------------P----------------------------------------------------------------------

P PUMP

PC PLUMBING CONTRACTOR

PNL PANEL

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH ABSOLUTE

PSIG POUNDS PER SQUARE INCH GAGE

PTAC PACKAGED TERMINAL AIR CONDITIONER

----------------Q----------------------------------------------------------------------

QTY QUANTITY

----------------R----------------------------------------------------------------------

RA RETURN AIR

RAD RADIATOR

RCP RADIANT CEILING PANEL

REFRIG REFRIGERANT

REQD REQUIRED

REV REVISION

RH RELATIVE HUMIDITY

RPM REVOLUTIONS PER MINUTE

RV RELIEF VALVE

----------------S----------------------------------------------------------------------

SA SUPPLY AIR

SCH SCHEDULE

SD SMOKE DAMPER

SENS SENSIBLE

SP STATIC PRESSURE (INCHES OF WATER)

SPEC SPECIFICATION

SQ SQUARE

SQFT SQUARE FOOT

SS STAINLESS STEEL

STD STANDARD

STRUCT STRUCTURAL

----------------T----------------------------------------------------------------------

T THERMOSTATE

TA TRANSFER AIR

TCV TEMPERATURE CONTROL VALVE

TDV TRIPLE DUTY VALVE

TEMP TEMPERATURE

TOT TOTAL

TRANS TRANSITION

TSTAT THERMOSTAT

TV TURNING VANES

TYP TYPICAL

----------------U----------------------------------------------------------------------

UH UNIT HEATER

UV UNIT VENTILATOR

----------------V----------------------------------------------------------------------

VOLTS VOLTAGE

VA VOLT AMPERES

VAC VACUUM

VAV VARIABLE AIR VOLUME

VEL VELOCITY

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

VOLTS VOLTAGE

VRF VARIABLE REFRIGERANT FLOW

VVT VARIABLE VOLUME AND TEMPERATURE

----------------W----------------------------------------------------------------------

W/ WITH

W/O WITHOUT

WP WEATHERPROOF

WT WEIGHT

----------------Z----------------------------------------------------------------------

Z ZONE

ZCV ZONE CONTROL VALVE

A. SPACE SET POINTS:

1. GENERAL SPACES SETPOINTS

a. COOLING: 73°F, 55% RH

b. HEATING: 70°F

B. OUTSIDE AIR CONDITIONS

1. SUMMER: 91°F WB, 72°F DB

2. WINTER: 2°F DB, 0°F WB

C. BUILDING ENVELOPE

1. WALLS: R-19

2. ROOF: R-30

3. WINDOWS: 0.588 U-VALUE

4. DOORS: 0.30 U-VALUE W/ 0.588 U-VALUE GLASS

D. KITCHEN EXHAUST / MAKE UP AIR

1. KITCHEN HOOD:

a. WALL MOUNT CANOPY

b. HEAVY DUTY - 350 CFM/FT

c. CLASS I W/ FIRE SUPPRESSION

2. MAKE UP AIR UNIT:

a. 80% OF KITCHEN EXHAUST CFM

E. DISHWASHER EXHAUST

1. DISHWASHER HOOD:

a. WALL MOUNT CANOPY

b. 200 CFM/FT

c. CLASS II (NO SUPPRESSION)

F. RESTROOM EXHAUST

1. 50 CFM PER WATER CLOSET / URINAL

G. DEMAND CONTROL VENTILATION

1. CO2 BASED UPON SPACE SENSORS

2. SEE RTU SCHEDULES FOR MAX & MIN VENTILATION RATES.

HVAC BASIS OF DESIGN

PA OFFICE:

429 LAUREL RUN ROAD

CARMICHAELS, PA 15320

PH: (724) 966-5655

WV OFFICE:

54 WEST RUN RD.

MORGANTOWN, WV 26508

PH: (304) 291-2234

SHEET NAME:

MILLER ENGINEERING INC.

COPY RIGHT:

CHECKED BY:

DRAWN BY:

DESIGNED BY:

BCM

SEAL:

CONSULTANT:

PROJECT NAME:

PROJECT OWNER:

PROJECT STATUS:

PROJECT NUMBER:

ORIGINAL PAGE SIZE: 22x34

M000

MECHANICAL

ABBREVIATIONS

12 OCT 2026

TRT

BCM

26010.1

ISSUED FOR

CONSTRUCTION

WVDNR

WVDNR CHIEF

LOGAN REC CENTER

POOL HVAC

RENOVATION

MECHANICAL ABBREVIATIONS

ANNOTATION STYLE DUCTWORK SHAPE

24" x 12" RECTANGULAR

24" ø ROUND

24" / 12" FLAT OVAL

DUCTWORK SHAPE LEGEND

DUCT SYSTEM LEGEND

ABBREVIATION SYSTEM NAME

EA EXHAUST AIR

OA OUTDOOR AIR

RA RETURN AIR

SA SUPPLY AIR

MECH PIPING SYSTEM LEGEND

ABBREVIATION SYSTEM TYPE

HCWR CHILLED WATER RETURN

HCWS CHILLED WATER SUPPLY

HHWL HEATING WATER LOOP

HHWR HEATING WATER RETURN

HHWS HEATING WATER SUPPLY

N O

D

ES

C

R

IP

TI

O

N D

A

TE

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL

LABOR REQUIRED TO INSTALL, COMPLETE, AND OPERATE AS

INDICATED ON THE DRAWINGS, SPECIFICATIONS, AND

REQUIRED BY CODE.

SEPARATE BALANCE DAMPERS WILL BE INSTALLED AT ALL

TAKE-OFFS FROM MAIN DUCTS. FIRE DAMPERS WILL BE

INSTALLED AT LOCATIONS SHOWN OR WHERE ANY DUCT

PENETRATES A FIRE RATED WALL. REFER TO ARCHITECTURAL

SHEETS FOR RATED WALLS. FIRE DAMPERS ARE TO MATCH THE

RATING OF THE WALL OR CEILING BEING PENETRATED.

ALL DUCT TAKE-OFFS AND TRANSITIONS WILL BE TAPERED.

ELBOWS AND TURNS SHALL BE CONSTRUCTED w/ A SMOOTH

RADIUSED FITTING MIN 1.5 TIMES THE WIDTH OF THE DUCT.

TURNING VANES ARE NOT PERMITTED, UNLESS APPROVED BY

ENGINEER OR INDICATED ON DRAWINGS.

CERTAIN ITEMS SUCH AS RISERS AND DROPS IN DUCTWORK,

ACCESS DOORS, VOLUME DAMPERS, ETC. ARE INDICATED ON

THE CONTRACT DOCUMENT DRAWINGS FOR CLARITY FOR A

SPECIFIC LOCATION REQUIREMENT AND SHALL NOT BE

INTERPRETED AS THE EXTENT OF THE REQUIREMENTS FOR

THOSE ITEMS.

ALL DUCTWORK IS TO BE EXTERNALLY INSULATED. INTERIOR

MOUNTED DUCTWORK SHALL HAVE FOIL FACED 1-1/2 TO 2"

FIBERGLASS INSULATION AND SEALED w/ FIBERGLASS

REINFORCED FOIL TAPE.

CONSTRUCT ALL DUCTWORK PER SMACNA STANDARDS FOR

LOW PRESSURE DUCTWORK (2.0" STATIC). ALL JOINTS ARE TO

BE SEALED w/ MASTIC.

PROVIDE AIR LOUVERS w/ GRAVITY BACKDRAFT DAMPERS. ALL

EXTERIOR LOUVERS WILL HAVE 60% MIN. OPEN AREA AND BUG

SCREENS. INSTALL ALL w/ BIRD SCREEN. COLORS BY OWNER/ARCHITECT. COORDINATE LOCATIONS w/ GENERAL

CONTRACTOR.

PROVIDE FULLY ADHERED VELOCITY DUCT LINER FROM UNIT

DISCHARGE AND RETURN TO 10'-0" BEYOND UNIT. PROVIDE

NOSING AT THE BEGINNING AND END OF THE DUCT LINER.

UNLESS OTHERWISE SHOWN, LOCATE…