Price Schedule Western Regional Incin.xlsx

XLSX spreadsheet 815 KB Posted

Attached to
SOURCES SOUGHT Regional HW Incineration Federal contract opportunity
Solicitation number
SP450026-HW_Incineration
Issued by
Defense Logistics Agency

About this file

The file is a Price Schedule for a Western Regional Hazardous Waste Incineration Contract, detailing specific service line items (CLINs) and associated pricing for waste management and disposal services. The document covers multiple service categories including overpack/loose pack services for containers ranging from 5-gallon pails to 110-gallon drums, special packaging for damaged/defective lithium batteries, certificate of disposal preparation, and waste disposal for various hazardous materials such as corrosive acids, oxidizers, and water-contaminated solvents. The price schedule includes estimated quantities for a 30-month base period and a 30-month option period, with all listed unit prices currently showing as zero dollars, suggesting pricing details may be forthcoming or separately negotiated.

The associated federal contract opportunity is a Sources Sought announcement by the Defense Logistics Agency (DLA) Disposition Services, seeking qualified large and small businesses to address an industry-wide hazardous waste incineration backlog. The solicitation aims to find contractors capable of removing incinerable or thermal-treated waste for Department of Defense and U.S. Coast Guard installations, specifically targeting the Western region (AZ, CA, CO, ID, MT, NM, NV, OR, UT, WA, and WY). The objective is to help waste generators meet Resource Conservation and Recovery Act (RCRA) storage requirements by providing reliable waste removal, transportation, incineration, and disposal services in compliance with local, state, and federal regulations.

View the file

Other files for this federal contract opportunity

Other files attached to SOURCES SOUGHT Regional HW Incineration, newest first.
File Type Posted
PWS Southeastern Regional HW Incin v.08.13.25.docx DOCX document
Price Schedule SE Regional Incin.xlsx XLSX spreadsheet
PWS Mid-America Regional HW Incin v.08.21.25.docx DOCX document
PWS Western Reg HW Incin v.08.12.25.docx DOCX document
PWS NE Regional Incin v.08.11.25.docx DOCX document
Price Schedule Mid-America Regional Incin.xlsx XLSX spreadsheet
Price Schedule NE Regional Incin.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Price Schedule Western INCIN

PRICE SCHEDULE
Western Regional HW Incineration Contract
SVC or

Base CLIN Service/Waste Description CLIN Est. Qty.

30-Month Base Est. Qty.

30-Month

OptionU/MBase
Unit PriceOption
Unit PriceBase

Extended Price Option Extended Price

1093SVSurcharge for Less Than Minimum Task Order.
One (1) EA will be ordered per TO having a total price for disposal CLINs under $900.00. See 0.0.1093SV1818EA$ - 0$ - 0$ - 0$ - 0
1202SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 5-gal pail. See 3.1.1202SV11EA$ - 0$ - 0$ - 0$ - 0
1203SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 15-gal drum. See 3.1.1203SV11EA$ - 0$ - 0$ - 0$ - 0
1204SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 30-gal drum. See 3.1.1204SV11EA$ - 0$ - 0$ - 0$ - 0
1205SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 55-gal drum. See 3.1.1205SV11EA$ - 0$ - 0$ - 0$ - 0
1206SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 110-gal drum. See 3.1.1206SV11EA$ - 0$ - 0$ - 0$ - 0
1207SVLoose Pack smaller container(s) into one Government-provided Cubic Yard Box (CYB) or Military Tri-Wall Box. See 3.1.1207SV11EA$ - 0$ - 0$ - 0$ - 0
1221SVProvide special packaging of DDR Lithium Batteries IAW TSDF acceptance criteria and current DOT regulations. Includes provision of all labor and supplies with outer container size up to 5-gallons. See 2.1 & 3.2.1221SV33EA$ - 0$ - 0$ - 0$ - 0
1300SVPrepare and provide one (1) Certificate of Disposal or Destruction (CD). See 3.3.1300SV11EA$ - 0$ - 0$ - 0$ - 0
1301SVPrepare and provide one (1) Hazardous Waste Profile Sheet (HWPS) or equivalent form. See 3.4.1301SV11EA$ - 0$ - 0$ - 0$ - 0
BA17Batteries, Lithium, Damaged, Defective, or Recalled (DDR), for RCRA incineration. Generator special packaging required. Outer container size up to 55-gal. Managed as UW only if casing isn't breached. See 2.1 & 3.2.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, UW. *See 2.3.BA17C7770770LB$ - 0$ - 0$ - 0$ - 0
CS08Corrosive Acids, Non-Fuming, Hydrofluoric (HF) <40% and/or Nitric (HNO3), <25% in Water.

Physical State: Liquid.

Permissible Waste Codes: D001 (OX), D002. No metals codes.CS08C111EA$ - 0$ - 0$ - 0$ - 0
CS08C411EA$ - 0$ - 0$ - 0$ - 0
CS09Corrosive Acids, Fuming, Hydrofluoric (HF) >40% and/or Nitric (HNO3), ≥25% in Water, may include Red Fuming Nitric Acid (RFNA).

Physical State: Liquid.

Permissible Waste Codes: D001 (OX), D002. No metals codes.CS09C111EA$ - 0$ - 0$ - 0$ - 0
CS09C411EA$ - 0$ - 0$ - 0$ - 0
CS12Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, Flashpoint ≥140°F.

Physical State: Various.

Permissible Waste Codes: D002, D004-8, D009*, D010-43, Listed. *See 2.3.CS12C13535EA$ - 0$ - 0$ - 0$ - 0
CS12C255EA$ - 0$ - 0$ - 0$ - 0
CS12C388EA$ - 0$ - 0$ - 0$ - 0
CS12C43232EA$ - 0$ - 0$ - 0$ - 0
CS12C511EA$ - 0$ - 0$ - 0$ - 0
CS12C611EA$ - 0$ - 0$ - 0$ - 0
CS13Corrosive Organic Acids or Bases, Liquids/Sludges/ Solids/Debris. No Ammonia or Amines. No inorganic acids or bases unless mixed with organic constituents. Flashpoint ≥140°F.

Physical State: Various.

Permissible Waste Codes: D002, D004-8, D009*, D010-43, Listed. *See 2.3.CS13C13636EA$ - 0$ - 0$ - 0$ - 0
CS13C233EA$ - 0$ - 0$ - 0$ - 0
CS13C31111EA$ - 0$ - 0$ - 0$ - 0
CS13C411EA$ - 0$ - 0$ - 0$ - 0
CS13C511EA$ - 0$ - 0$ - 0$ - 0
CS13C611EA$ - 0$ - 0$ - 0$ - 0
CS15Corrosive Aerosols, Non-Ignitable and Non-Reactive, even when managed as UW.

Physical State: Various.

Permissible Waste Codes: UW, D002, D004-8, D009*, D010-43, Listed. *See 2.3.CS15C711LB$ - 0$ - 0$ - 0$ - 0
FL01Aerosols, Flammable/Combustible/Ignitable, Non-foaming. No isocyanates, reactives, or corrosives, even when managed as UW.

Physical State: Various

Permissible Waste Codes: Universal Waste, D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL01C75,0075,007LB$ - 0$ - 0$ - 0$ - 0
FL02Flammable Debris contaminated with common solvents, shreddable, no free liquids, no large metal, rock, or masonry components.

Physical State: Solid.

Permissible Waste Codes: D001, D004-8, D009*, D010-43, Listed. *See 2.3.FL02C199EA$ - 0$ - 0$ - 0$ - 0
FL02C266EA$ - 0$ - 0$ - 0$ - 0
FL02C32929EA$ - 0$ - 0$ - 0$ - 0
FL02C4129129EA$ - 0$ - 0$ - 0$ - 0
FL02C611EA$ - 0$ - 0$ - 0$ - 0
FL03Flammable Liquids/Solids/Sludges/Debris, e.g., tank sludge, lubricants, adhesives, contaminated rags and other debris. Consists of non-fuels-blendable materials. Use LP03 for loose packs. No paints or coatings eligible for FL16.

Physical State: Various.

Permissible Waste Codes: D001-2, D004-8, D009*, D010-43, Listed. *See 2.3.FL03C1139139EA$ - 0$ - 0$ - 0$ - 0
FL03C25151EA$ - 0$ - 0$ - 0$ - 0
FL03C3137137EA$ - 0$ - 0$ - 0$ - 0
FL03C4320320EA$ - 0$ - 0$ - 0$ - 0
FL03C533EA$ - 0$ - 0$ - 0$ - 0
FL03C62323EA$ - 0$ - 0$ - 0$ - 0
FL03T211EA$ - 0$ - 0$ - 0$ - 0
FL04Flammable Corrosive Liquids/Solids/Sludges/ Debris/Aerosols. Use LP03 for loose packs other than aerosols. FL04C7 for use with flammable corrosive aerosols only.

Physical State: Various.

Permissible Waste Codes: UW (Aerosols Only), D001 (IGN), D002, D004-8, D009*, D010-43, Listed. *See 2.3.FL04C17373EA$ - 0$ - 0$ - 0$ - 0
FL04C21818EA$ - 0$ - 0$ - 0$ - 0
FL04C311EA$ - 0$ - 0$ - 0$ - 0
FL04C42222EA$ - 0$ - 0$ - 0$ - 0
FL04C711LB$ - 0$ - 0$ - 0$ - 0
FL05Flammable Liquids, Pumpable, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine. See 2.4.1. No isocyanates or other polymerizable components.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL05C19191EA$ - 0$ - 0$ - 0$ - 0
FL05C21111EA$ - 0$ - 0$ - 0$ - 0
FL05C31616EA$ - 0$ - 0$ - 0$ - 0
FL05C4192192EA$ - 0$ - 0$ - 0$ - 0
FL05C511EA$ - 0$ - 0$ - 0$ - 0
FL05C622EA$ - 0$ - 0$ - 0$ - 0
FL05T211EA$ - 0$ - 0$ - 0$ - 0
FL06Flammable Liquids, Pumpable, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates or other polymerizable components.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL06C155EA$ - 0$ - 0$ - 0$ - 0
FL06C211EA$ - 0$ - 0$ - 0$ - 0
FL06C355EA$ - 0$ - 0$ - 0$ - 0
FL06C41919EA$ - 0$ - 0$ - 0$ - 0
FL06C511EA$ - 0$ - 0$ - 0$ - 0
FL07Flammable Liquids, Pumpable, Fuels Blendable, Lean to Rich, >2,500 BTU/Lb, 5-10% total chlorine, no isocyanates or other polymerizable components.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL07C111EA$ - 0$ - 0$ - 0$ - 0
FL07C211EA$ - 0$ - 0$ - 0$ - 0
FL07C311EA$ - 0$ - 0$ - 0$ - 0
FL07C422EA$ - 0$ - 0$ - 0$ - 0
FL07C511EA$ - 0$ - 0$ - 0$ - 0
FL08Flammable Resuspendable Solids/Sludges, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine, no isocyanates or other polymerizable components.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL08C111EA$ - 0$ - 0$ - 0$ - 0
FL08C311EA$ - 0$ - 0$ - 0$ - 0
FL08C411EA$ - 0$ - 0$ - 0$ - 0
FL09Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates or other polymerizable components.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL09C111EA$ - 0$ - 0$ - 0$ - 0
FL09C411EA$ - 0$ - 0$ - 0$ - 0
FL10Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean to Rich, greater than 2,500 BTU/Lb, 5-10% total chlorine, no isocyanates or other polymerizable components.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL10C111EA$ - 0$ - 0$ - 0$ - 0
FL10C411EA$ - 0$ - 0$ - 0$ - 0
FL11Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed, UW (Pesticides Only). *See 2.3.FL11C188EA$ - 0$ - 0$ - 0$ - 0
FL11C411EA$ - 0$ - 0$ - 0$ - 0
FL12Flammable Solids/Sludges, Highly Chlorinated (>10%), Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed, UW (Pesticides Only). *See 2.3.FL12C11212EA$ - 0$ - 0$ - 0$ - 0
FL12C411EA$ - 0$ - 0$ - 0$ - 0
FL13Oxidizers, Non-Reactive, Liquids/Sludges/Solids/ Debris, other than chromic acid (see Corrosives).

Physical State: Various.

Permissible Waste Codes: D001(OX), D002, D004-8, D009*. D010-43, Listed. *See 2.3.FL13C13535EA$ - 0$ - 0$ - 0$ - 0
FL13C211EA$ - 0$ - 0$ - 0$ - 0
FL13C377EA$ - 0$ - 0$ - 0$ - 0
FL13C42222EA$ - 0$ - 0$ - 0$ - 0
FL13C511EA$ - 0$ - 0$ - 0$ - 0
FL13C611EA$ - 0$ - 0$ - 0$ - 0
FL15Water Contaminated with Common Solvents, <2,500 BTU/Lb.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL15C155EA$ - 0$ - 0$ - 0$ - 0
FL15C211EA$ - 0$ - 0$ - 0$ - 0
FL15C311EA$ - 0$ - 0$ - 0$ - 0
FL15C411EA$ - 0$ - 0$ - 0$ - 0
FL15C511EA$ - 0$ - 0$ - 0$ - 0
FL15T211EA$ - 0$ - 0$ - 0$ - 0
FL16Non-Reactive paints and other coatings listing isocyanates, amines, or other polymerizable components in the ingredients. Non-fuels-blendable. Use LP16 for loose packs.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.FL16C188EA$ - 0$ - 0$ - 0$ - 0
FL16C255EA$ - 0$ - 0$ - 0$ - 0
FL16C38383EA$ - 0$ - 0$ - 0$ - 0
FL16C48888EA$ - 0$ - 0$ - 0$ - 0
FL16C511EA$ - 0$ - 0$ - 0$ - 0
FL16C61717EA$ - 0$ - 0$ - 0$ - 0
FL75Flammable Aerosols, paints and paint-related materials, non-foaming, no isocyanates, State-specific Universal Waste (UW).

Physical State: Various.

Permissible Waste Codes: UW.FL75C711LB$ - 0$ - 0$ - 0$ - 0
FL77Flammable Liquids, paints and paint-related materials, pumpable, rich, >7,000 BTU/Lb, <5% total chlorine, State-specific Universal Waste (UW).

Physical State: Liquid.

Permissible Waste Codes: UW.FL77C111EA$ - 0$ - 0$ - 0$ - 0
FL77C411EA$ - 0$ - 0$ - 0$ - 0
FL78Flammable Liquids, paints and paint-related wastes, pumpable, lean, 2,500-7,000 BTU/Lb, <5% total chlorine, State-specific Universal Waste (UW).

Physical State: Liquid.

Permissible Waste Codes: UW.FL78C111EA$ - 0$ - 0$ - 0$ - 0
FL78C411EA$ - 0$ - 0$ - 0$ - 0
FL79Flammable Solids/Sludges/Debris, paints and paint-related wastes, FLP <140° F, State-specific Universal Waste (UW).

Physical State: Various.

Permissible Waste Codes: UW.FL79C111EA$ - 0$ - 0$ - 0$ - 0
FL79C411EA$ - 0$ - 0$ - 0$ - 0
FL99Military Items, Demil-required, Flammable Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. for conventional RCRA treatment, disposal. CD required.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D002, D004-8, D009*, D010-43, Listed. *See 2.3.FL99C7325325LB$ - 0$ - 0$ - 0$ - 0
LP01Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.

Physical State: Various.

Permissible Waste Codes: D002, D004-8, D009*, D010-43, Listed Corrosives. *See 2.3.LP01C1115115EA$ - 0$ - 0$ - 0$ - 0
LP01C22020EA$ - 0$ - 0$ - 0$ - 0
LP01C31616EA$ - 0$ - 0$ - 0$ - 0
LP01C42323EA$ - 0$ - 0$ - 0$ - 0
LP01C511EA$ - 0$ - 0$ - 0$ - 0
LP01C611EA$ - 0$ - 0$ - 0$ - 0
LP01M111EA$ - 0$ - 0$ - 0$ - 0
LP01M211EA$ - 0$ - 0$ - 0$ - 0
LP03Lap Packs/Loose Packs, Flammables and Flammable Corrosives, including solvent-based products, adhesives, lubricants, etc. No flammable metals. No paint/coating products eligible for LP14 or LP16.

Physical State: Various.

Permissible Waste Codes: D001-2, D004-8, D009*, D010-43, Listed Flammables. *See 2.3.LP03C1595595EA$ - 0$ - 0$ - 0$ - 0
LP03C2122122EA$ - 0$ - 0$ - 0$ - 0
LP03C3111111EA$ - 0$ - 0$ - 0$ - 0
LP03C4523523EA$ - 0$ - 0$ - 0$ - 0
LP03C522EA$ - 0$ - 0$ - 0$ - 0
LP03C62323EA$ - 0$ - 0$ - 0$ - 0
LP03M111EA$ - 0$ - 0$ - 0$ - 0
LP03M211EA$ - 0$ - 0$ - 0$ - 0
LP04Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, no pharmaceuticals (see LP78). For mandatory RCRA incineration.

Physical State: Various.

Permissible EPA Waste Codes: N/A.LP04C111EA$ - 0$ - 0$ - 0$ - 0
LP04C211EA$ - 0$ - 0$ - 0$ - 0
LP04C311EA$ - 0$ - 0$ - 0$ - 0
LP04C411EA$ - 0$ - 0$ - 0$ - 0
LP04C611EA$ - 0$ - 0$ - 0$ - 0
LP05Lab Packs/Loose Packs, Non-Reactive Oxidizers, for mandatory RCRA incineration.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D002, D004-8, D009*, D010-43, Listed. *See 2.3.LP05C1114114EA$ - 0$ - 0$ - 0$ - 0
LP05C22424EA$ - 0$ - 0$ - 0$ - 0
LP05C33333EA$ - 0$ - 0$ - 0$ - 0
LP05C46767EA$ - 0$ - 0$ - 0$ - 0
LP05C611EA$ - 0$ - 0$ - 0$ - 0
LP05M111EA$ - 0$ - 0$ - 0$ - 0
LP05M211EA$ - 0$ - 0$ - 0$ - 0
LP06Lab Packs/Loose Packs, Reactive Oxidizers, including Organic Peroxides, for mandatory RCRA incineration. Special Generator packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D002-8, D009*, D010-43, Listed. *See 2.3.LP06C14141EA$ - 0$ - 0$ - 0$ - 0
LP06C21212EA$ - 0$ - 0$ - 0$ - 0
LP06C377EA$ - 0$ - 0$ - 0$ - 0
LP06C41313EA$ - 0$ - 0$ - 0$ - 0
LP06C511EA$ - 0$ - 0$ - 0$ - 0
LP06C611EA$ - 0$ - 0$ - 0$ - 0
LP06M111EA$ - 0$ - 0$ - 0$ - 0
LP06M211EA$ - 0$ - 0$ - 0$ - 0
LP07Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, includes Broken Sodium Lamps, MRE heaters, E-cigarettes and associated components and residues. Special Generator packaging may be required. May include non-reactive metals. Reactive metals must meet RX08 special packaging requirements.

Physical State: Various.

Permissible Waste Codes: D001, D003-8, D009*, D010-43, Listed. *See 2.3.LP07C13838EA$ - 0$ - 0$ - 0$ - 0
LP07C22828EA$ - 0$ - 0$ - 0$ - 0
LP07C355EA$ - 0$ - 0$ - 0$ - 0
LP07C411EA$ - 0$ - 0$ - 0$ - 0
LP07C511EA$ - 0$ - 0$ - 0$ - 0
LP07M111EA$ - 0$ - 0$ - 0$ - 0
LP07M211EA$ - 0$ - 0$ - 0$ - 0
LP08Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, for mandatory RCRA incineration. Special Generator packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.LP08C13131EA$ - 0$ - 0$ - 0$ - 0
LP08C266EA$ - 0$ - 0$ - 0$ - 0
LP08C311EA$ - 0$ - 0$ - 0$ - 0
LP08C466EA$ - 0$ - 0$ - 0$ - 0
LP08C511EA$ - 0$ - 0$ - 0$ - 0
LP08C611EA$ - 0$ - 0$ - 0$ - 0
LP08M111EA$ - 0$ - 0$ - 0$ - 0
LP08M211EA$ - 0$ - 0$ - 0$ - 0
LP10Lab Packs/Loose Packs, Toxic Organics, for mandatory RCRA incineration.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.LP10C17878EA$ - 0$ - 0$ - 0$ - 0
LP10C299EA$ - 0$ - 0$ - 0$ - 0
LP10C399EA$ - 0$ - 0$ - 0$ - 0
LP10C41818EA$ - 0$ - 0$ - 0$ - 0
LP10C511EA$ - 0$ - 0$ - 0$ - 0
LP10C611EA$ - 0$ - 0$ - 0$ - 0
LP10M111EA$ - 0$ - 0$ - 0$ - 0
LP10M211EA$ - 0$ - 0$ - 0$ - 0
LP11Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, for mandatory RCRA incineration. Includes pharmaceuticals. May be packaged with U-Listed waste.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, P-Listed, U-Listed. *See 2.3.LP11C17474EA$ - 0$ - 0$ - 0$ - 0
LP11C255EA$ - 0$ - 0$ - 0$ - 0
LP11C311EA$ - 0$ - 0$ - 0$ - 0
LP11C411EA$ - 0$ - 0$ - 0$ - 0
LP11C511EA$ - 0$ - 0$ - 0$ - 0
LP11M111EA$ - 0$ - 0$ - 0$ - 0
LP11M211EA$ - 0$ - 0$ - 0$ - 0
LP12Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals, for mandatory RCRA incineration.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, U-Listed. *See 2.3.LP12C15858EA$ - 0$ - 0$ - 0$ - 0
LP12C288EA$ - 0$ - 0$ - 0$ - 0
LP12C31414EA$ - 0$ - 0$ - 0$ - 0
LP12C42020EA$ - 0$ - 0$ - 0$ - 0
LP12C511EA$ - 0$ - 0$ - 0$ - 0
LP12C611EA$ - 0$ - 0$ - 0$ - 0
LP12M111EA$ - 0$ - 0$ - 0$ - 0
LP12M211EA$ - 0$ - 0$ - 0$ - 0
LP13Lab Packs/Loose Packs, Pesticides, for mandatory RCRA incineration. See CLIN LP77 for management as UW.

Physical State: Various.

Ermissible Waste Codes: D004-8, D009*, D010-43, U-Listed. *See 2.3.LP13C111EA$ - 0$ - 0$ - 0$ - 0
LP13C411EA$ - 0$ - 0$ - 0$ - 0
LP14Loose-Packed Paints and Paint-Related Materials, Primarily Oil/Petroleum-Based, >7,000 BTU/Lb. May contain incidental Latex paints. No isocyanates or other polymerizable components. Fuels blendable.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.LP14C15252EA$ - 0$ - 0$ - 0$ - 0
LP14C26666EA$ - 0$ - 0$ - 0$ - 0
LP14C32929EA$ - 0$ - 0$ - 0$ - 0
LP14C4517517EA$ - 0$ - 0$ - 0$ - 0
LP14C599EA$ - 0$ - 0$ - 0$ - 0
LP14C64040EA$ - 0$ - 0$ - 0$ - 0
LP16Loose-Packed Paints and Paint-Related Materials, Primarily Oil/Petroleum-Based, >7,000 BTU/Lb. May contain incidental Latex paints. No isocyanates or other polymerizable components. Fuels blendable.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-8, D009*, D010-43, Listed. *See 2.3.LP16C199EA$ - 0$ - 0$ - 0$ - 0
LP16C222EA$ - 0$ - 0$ - 0$ - 0
LP16C3104104EA$ - 0$ - 0$ - 0$ - 0
LP16C4228228EA$ - 0$ - 0$ - 0$ - 0
LP16C511EA$ - 0$ - 0$ - 0$ - 0
LP16C61414EA$ - 0$ - 0$ - 0$ - 0
LP77Lab Packs/Loose Packs, Pesticides, Managed as UW per 40 CFR 273.3.

Physical State: Various.

Permissible Waste Codes: UW.LP77C111EA$ - 0$ - 0$ - 0$ - 0
LP77C411EA$ - 0$ - 0$ - 0$ - 0
LP78Lab Packs/Loose Packs, Pharmaceuticals, including aerosols, non-RCRA, prescription and non-prescription. No DEA-controlled drugs. For mandatory RCRA Incineration. CD required.

Physical State: Various.

Permissible Waste Codes: N/A.LP78C111EA$ - 0$ - 0$ - 0$ - 0
LP78C211EA$ - 0$ - 0$ - 0$ - 0
LP78C311EA$ - 0$ - 0$ - 0$ - 0
LP78C411EA$ - 0$ - 0$ - 0$ - 0
LP78M111EA$ - 0$ - 0$ - 0$ - 0
LP78M211EA$ - 0$ - 0$ - 0$ - 0
LP79Lab Packs/Loose Packs, Miscellaneous laboratory-related wastes including preserved specimens, microscope slides, etc. No infectious or biohazardous wastes. May require a Non-Biohazardous or Non-Infectious Certificate.

Physical State: Various.

Permissible Waste Codes: N/A.LP79C111EA$ - 0$ - 0$ - 0$ - 0
LP79C211EA$ - 0$ - 0$ - 0$ - 0
LP79C311EA$ - 0$ - 0$ - 0$ - 0
LP79C411EA$ - 0$ - 0$ - 0$ - 0
NR04Non-RCRA Liquids, Organic-Based, pumpable, primarily consisting of wastes containing hydrocarbons.

Physical State: Liquid.

Permissible Waste Codes: N/A.NR04C111EA$ - 0$ - 0$ - 0$ - 0
NR04C411EA$ - 0$ - 0$ - 0$ - 0
NR07Non-RCRA Pharmaceuticals, prescription and non-prescription, for mandatory RCRA incineration. No DEA-restricted meds. Use LP79 for lab packs/loose packs. CD required.

Physical State: Various.

Permissible Waste Codes: N/A.NR07C111EA$ - 0$ - 0$ - 0$ - 0
NR07C211EA$ - 0$ - 0$ - 0$ - 0
NR07C311EA$ - 0$ - 0$ - 0$ - 0
NR07C411EA$ - 0$ - 0$ - 0$ - 0
NR07C611EA$ - 0$ - 0$ - 0$ - 0
NR78Non-RCRA Military Items for Demil, Debris/Liquids/ Solids and Sludge. Includes State Regulated decontaminated Chemical Agent related waste. Non-Flammable, i.e. CDE kits, Vials, filters, PPE, etc. for mandatory incineration. CD required.

Physical State: Various.

Permissible Waste Codes: N/A.NR78C111EA$ - 0$ - 0$ - 0$ - 0
NR78C211EA$ - 0$ - 0$ - 0$ - 0
NR78C311EA$ - 0$ - 0$ - 0$ - 0
NR78C411EA$ - 0$ - 0$ - 0$ - 0
NR78C611EA$ - 0$ - 0$ - 0$ - 0
NR96Non-RCRA Liquids for RCRA Incineration, pumpable. Not used for AFFF or other PFAS-related wastes. CD required.

Physical State: Liquid.

Permissible Waste Codes: N/A.NR96C11818EA$ - 0$ - 0$ - 0$ - 0
NR96C211EA$ - 0$ - 0$ - 0$ - 0
NR96C311EA$ - 0$ - 0$ - 0$ - 0
NR96C41010EA$ - 0$ - 0$ - 0$ - 0
NR96C611EA$ - 0$ - 0$ - 0$ - 0
NR97Non-RCRA Solids/Sludges/Debris for RCRA Incineration. May contain some free liquids. Not used for AFFF or other PFAS-related wastes. CD required.

Physical State: Various.

Permissible Waste Codes: N/A.NR97C13232EA$ - 0$ - 0$ - 0$ - 0
NR97C211EA$ - 0$ - 0$ - 0$ - 0
NR97C311EA$ - 0$ - 0$ - 0$ - 0
NR97C41111EA$ - 0$ - 0$ - 0$ - 0
NR97C611EA$ - 0$ - 0$ - 0$ - 0
PC01PCB wastes containing or contaminated with at least a 50 ppm source (5 ppm in CA, 2 ppm in WA), RCRA or Non-RCRA, e.g., fluids, soil, sludge, debris, leaking capacitors. CD required. See 2.2.

Physical State: Various.

Permissible Waste Codes: D001-8, D010-43, Listed.PC01C82222KG$ - 0$ - 0$ - 0$ - 0
PC03PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs (5-4,000 ppm in CA, 2-4,000 ppm in WA). Non-RCRA, CD required. See 2.2.

Physical State: Liquid.

Permissible Waste Codes: N/A.PC03C811KG$ - 0$ - 0$ - 0$ - 0
PC04PCB Mineral Oil, Water, Other Fluids, more than 4,000 ppm PCBs. RCRA or Non-RCRA. CD required. See 2.2.

Physical State: Liquid.

Permissible Waste Codes: D001-8, D010-43, Listed.PC04C811KG$ - 0$ - 0$ - 0$ - 0
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, at least 50 ppm PCBs (5 ppm in CA, 2 ppm in WA), Non-RCRA, CD required. See 2.2.

Physical State: Various.

Permissible Waste Codes: N/A.PC06C8126126KG$ - 0$ - 0$ - 0$ - 0
PC08PCB Oil-Filled Transformers, at least 50 ppm PCBs (5 ppm in CA, 2 ppm in WA). CD required. See 2.2.

Physical State: Various.

Permissible Waste Codes: N/A.PC08C811KG$ - 0$ - 0$ - 0$ - 0
PC10PCB Solids/Debris Contaminated with at least a 50 ppm Source (5 ppm in CA, 2 ppm in WA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA. CD required. See 2.2.

Physical State: Solid.

Permissible Waste Codes: N/A.PC10C811KG$ - 0$ - 0$ - 0$ - 0
PF10PFAS-containing Liquids/Solids/Sludges/Debris, Flammable/Combustible/Ignitable, for RCRA incineration.

Physical State: Various.

Permissible Waste Codes: D001, D002, D004-8, D009*, D010-43, Listed. *See 2.3.PF10C111EA$ - 0$ - 0$ - 0$ - 0
PF10C411EA$ - 0$ - 0$ - 0$ - 0
PF11PFAS-containing Liquids/Solids/Sludges/Debris, Corrosive, for RCRA incineration. CD required.

Physical State: Various.

Permissible Waste Codes: D002, D004-8, D009*, D010-43, Listed. *See 2.3.PF11C111EA$ - 0$ - 0$ - 0$ - 0
PF11C411EA$ - 0$ - 0$ - 0$ - 0
PF12PFAS-containing Liquids/Solids/Sludges/Debris, Reactive, for RCRA incineration. CD required.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.PF12C111EA$ - 0$ - 0$ - 0$ - 0
PF12C411EA$ - 0$ - 0$ - 0$ - 0
PF13PFAS-containing Liquids/Solids/Sludges/Debris, Toxic, for RCRA incineration. CD required.

Physical State: Various.

Permissible EPA Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.PF13C111EA$ - 0$ - 0$ - 0$ - 0
PF13C411EA$ - 0$ - 0$ - 0$ - 0
PF20PFAS and AFFF-impacted solids, sludges, and debris, e.g., spill-related solids, soil, gravel, filter media, tank bladders, etc. Non-RCRA, for RCRA incineration. May contain some free liquids.

Physical State: Various.

Permissible Waste Codes: N/A.PF20C142EA$ - 0$ - 0$ - 0$ - 0
PF20C221EA$ - 0$ - 0$ - 0$ - 0
PF20C321EA$ - 0$ - 0$ - 0$ - 0
PF20C45728EA$ - 0$ - 0$ - 0$ - 0
PF20C511EA$ - 0$ - 0$ - 0$ - 0
PF20C6219EA$ - 0$ - 0$ - 0$ - 0
PF21PFAS and AFFF high-concentrate liquids, pumpable, Non-RCRA, for RCRA incineration. Unused or more than 10% product by volume.

Physical State: Liquid.

Permissible Waste Codes: N/A.PF21C110714EA$ - 0$ - 0$ - 0$ - 0
PF21C211EA$ - 0$ - 0$ - 0$ - 0
PF21C341EA$ - 0$ - 0$ - 0$ - 0
PF21C4123EA$ - 0$ - 0$ - 0$ - 0
PF21C511EA$ - 0$ - 0$ - 0$ - 0
PF21T111EA$ - 0$ - 0$ - 0$ - 0
PF21T24812EA$ - 0$ - 0$ - 0$ - 0
PF21T311EA$ - 0$ - 0$ - 0$ - 0
PF22PFAS and AFFF rinsates and other impacted waters, pumpable, Non-RCRA, for RCRA incineration. At least 90% water by volume.

Physical State: Liquid.

Permissible Waste Codes: N/A.PF22C1195EA$ - 0$ - 0$ - 0$ - 0
PF22C241EA$ - 0$ - 0$ - 0$ - 0
PF22C3123EA$ - 0$ - 0$ - 0$ - 0
PF22C420447EA$ - 0$ - 0$ - 0$ - 0
PF22C511EA$ - 0$ - 0$ - 0$ - 0
PF22T111EA$ - 0$ - 0$ - 0$ - 0
PF22T219655EA$ - 0$ - 0$ - 0$ - 0
PF22T3205EA$ - 0$ - 0$ - 0$ - 0
RX01Aerosols, Foaming, Isocyanates or other reactives.

Physical State: Various.

Permissible Waste Codes: UW, D001-8, D009*, D010-43, Listed. *See 2.3.RX01C7987987LB$ - 0$ - 0$ - 0$ - 0
RX02Cyanide, >50% Debris, >590 mg/Kg Total CN.

Physical State: Various.

Permissible Waste Codes: D002-8, D009*, D010-43, Listed. *See 2.3.RX02C111EA$ - 0$ - 0$ - 0$ - 0
RX02C411EA$ - 0$ - 0$ - 0$ - 0
RX03Cyanide Liquids, Solids, <50% Debris, 590-10,000 mg/Kg (1%) Total CN.

Physical State: Various.

Permissible Waste Codes: D002-8, D009*, D010-43, Listed. *See 2.3.RX03C122EA$ - 0$ - 0$ - 0$ - 0
RX03C411EA$ - 0$ - 0$ - 0$ - 0
RX04Cyanide Liquids, Solids, <50% Debris, 1%-10% Total CN.

Physical State: Various.

Permissible Waste Codes: D002-8, D009*, D010-43, Listed. *See 2.3.RX04C111EA$ - 0$ - 0$ - 0$ - 0
RX04C411EA$ - 0$ - 0$ - 0$ - 0
RX05Cyanide Liquids, Solids, <50% Debris, >10% Total CN.

Physical State: Various.

Permissible Waste Codes: D002-8, D009*, D010-43, Listed. *See 2.3.RX05C144EA$ - 0$ - 0$ - 0$ - 0
RX05C411EA$ - 0$ - 0$ - 0$ - 0
RX06Reactive Oxidizers, e.g., Nitrates, Nitrites, Persulfates, Inorganic Peroxides, No Organic Peroxides. Special Generator packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.RX06C177EA$ - 0$ - 0$ - 0$ - 0
RX06C211EA$ - 0$ - 0$ - 0$ - 0
RX06C311EA$ - 0$ - 0$ - 0$ - 0
RX06C411EA$ - 0$ - 0$ - 0$ - 0
RX07Polymerizing Materials, e.g, Styrene, Isocyanates, Acrylates, etc. Special Generator packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.RX07C111EA$ - 0$ - 0$ - 0$ - 0
RX07C211EA$ - 0$ - 0$ - 0$ - 0
RX07C311EA$ - 0$ - 0$ - 0$ - 0
RX07C411EA$ - 0$ - 0$ - 0$ - 0
RX08Reactive Metals, powders, dusts, fines. Air/Water Reactive. Special Generator packaging required. See 1.2.3.

Physical State: Solid.

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.RX08C1103103EA$ - 0$ - 0$ - 0$ - 0
RX08C23232EA$ - 0$ - 0$ - 0$ - 0
RX08C399EA$ - 0$ - 0$ - 0$ - 0
RX08C42828EA$ - 0$ - 0$ - 0$ - 0
RX09Reactive Metals, debris. Air/Water Reactive. Special Generator packaging required. See 1.2.3.

Physical State: Solid.

Permissible Waste Codes: D001-8, D009*, D010-11, Listed. *See 2.3.RX09C188EA$ - 0$ - 0$ - 0$ - 0
RX09C211EA$ - 0$ - 0$ - 0$ - 0
RX09C322EA$ - 0$ - 0$ - 0$ - 0
RX09C411EA$ - 0$ - 0$ - 0$ - 0
RX10Reactive Non-Metals, e.g., P-Coded, Temperature Sensitive, PIHs, Air/Water Reactive. Special Generator packaging required.

Physical State: Solid.

Permissible Waste Codes: D001-8, D009*, D010-11, Listed. *See 2.3.RX10C12121EA$ - 0$ - 0$ - 0$ - 0
RX10C211EA$ - 0$ - 0$ - 0$ - 0
RX10C311EA$ - 0$ - 0$ - 0$ - 0
RX10C411EA$ - 0$ - 0$ - 0$ - 0
RX95Reactive, Ignitable, and Toxic Solids, Sludges, and Debris, for RCRA Incineration. Contaminated w/ Mineral Spirits, Motor Oil, Alcohol, Solvents, Otto Fuel. <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.

Physical State: Various.

Permissible Waste Codes: D001-8, D009*, D010-11, Listed. *See 2.3.RX95C111EA$ - 0$ - 0$ - 0$ - 0
RX96Reactive Electron Tubes for Demil and Disposal, Water Reactive, Intact, Contains Non-Radioactive Cesium. CD required.

Physical State" Solid

Permissible Waste Codes: D001-8, D009*, D010-43, Listed. *See 2.3.RX96C711LB$ - 0$ - 0$ - 0$ - 0
RX97Reactive, Ignitable, and Toxic Liquid for RCRA incineration. Contains Water, Mineral Spirits, Motor Oil, <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.

Physical State: Liquid.

Permissible Waste Codes: D001, D003-8, D009*, D010-43, Listed. *See 2.3.RX97C111EA$ - 0$ - 0$ - 0$ - 0
RX97C411EA$ - 0$ - 0$ - 0$ - 0
RX97T21414EA$ - 0$ - 0$ - 0$ - 0
RX99Reactive, Military Items, Demil-Required, Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. (No Batteries) for RCRA incineration. Generator special packaging may be required. Must Carry D003. CD required.

Physical State: Various.

Permissible Waste Codes: D001-8, D010-D043, Listed. *See 2.3.RX99C111EA$ - 0$ - 0$ - 0$ - 0
RX99C211EA$ - 0$ - 0$ - 0$ - 0
RX99C311EA$ - 0$ - 0$ - 0$ - 0
RX99C411EA$ - 0$ - 0$ - 0$ - 0
TX07Toxic, Debris, Organic Constituents. Must include organic Waste Code(s). May include inorganic Waste Code(s) and/or RCRA hazardous asbestos.

Physical State: Debris.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed, but no F020-32. *See 2.3.TX07C11919EA$ - 0$ - 0$ - 0$ - 0
TX07C21111EA$ - 0$ - 0$ - 0$ - 0
TX07C31818EA$ - 0$ - 0$ - 0$ - 0
TX07C49999EA$ - 0$ - 0$ - 0$ - 0
TX07C511EA$ - 0$ - 0$ - 0$ - 0
TX07C62424EA$ - 0$ - 0$ - 0$ - 0
TX09Toxic, High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides.

Physical State: Various.

Permissible Waste Codes: UW, D004-8, D009*, D010-43, Listed. *See 2.3.TX09C12626EA$ - 0$ - 0$ - 0$ - 0
TX09C222EA$ - 0$ - 0$ - 0$ - 0
TX09C31717EA$ - 0$ - 0$ - 0$ - 0
TX09C4121121EA$ - 0$ - 0$ - 0$ - 0
TX09C511EA$ - 0$ - 0$ - 0$ - 0
TX21Toxic Organics Contaminated Water, Pumpable, <10% Suspended Solids, <10% Organics, e.g., Toluene, Phenol in water. Not more toxic than common solvents.

Physical State: Liquid.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.TX21C177EA$ - 0$ - 0$ - 0$ - 0
TX21C233EA$ - 0$ - 0$ - 0$ - 0
TX21C322EA$ - 0$ - 0$ - 0$ - 0
TX21C45252EA$ - 0$ - 0$ - 0$ - 0
TX21T211EA$ - 0$ - 0$ - 0$ - 0
TX22Toxic Organics in Solids/Sludges/Debris, i.e. soil, tank & still bottoms, adhesives, filtercake. Not more toxic than common solvents.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.TX22C12525EA$ - 0$ - 0$ - 0$ - 0
TX22C233EA$ - 0$ - 0$ - 0$ - 0
TX22C399EA$ - 0$ - 0$ - 0$ - 0
TX22C47373EA$ - 0$ - 0$ - 0$ - 0
TX24Toxic Organic Solvents, Technical grade, pure or mixed solutions, with or without water and/or metals, Flashpoint >140°F.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.TX24C144EA$ - 0$ - 0$ - 0$ - 0
TX24C211EA$ - 0$ - 0$ - 0$ - 0
TX24C311EA$ - 0$ - 0$ - 0$ - 0
TX24C44343EA$ - 0$ - 0$ - 0$ - 0
TX98Toxic, Military Items, Demil-required, RCRA Toxic, e.g., CDE Kits, Tents, Filters, PPE, etc. for RCRA incineration. CD required.

Physical State: Various.

Permissible Waste Codes: D004-8, D009*, D010-43, Listed. *See 2.3.TX98C7112112LB$ - 0$ - 0$ - 0$ - 0
TX99Submarine and Special Hull Treatment tiles. Demil-required via RCRA Incineration. For use even when no toxic EPA Waste Codes apply. Not for bulk removals. Restricted transportation requirements apply. See 2.5.1. Generator(s) must acquire written authorization from their Command Leadership to utilize this CLIN. Certificate of Destruction required.

Physical State: Solid.

Permissible Waste Codes: D004-8, D009*, D010-43. *See 2.3.TX99C7124,862124,862LB$ - 0$ - 0$ - 0$ - 0
$ - 0$ - 0

29-Mo Ordering Hx

DTIDGen EPA ID#Gen DescriptionPick Up DoDAACReceipt Dt (UTC)PIID Award Date (UTC):Turnin TypeStatusCLINQtyU/MNoun DescriptionContractPIIDHWD Doc Nr
N6247A4073D400CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP05C11EA6810DSOXIDZLP, HO41, UN2014, WASTE HYDROGEN PEROXIDE AQUEOUS SOLUTION, 5.1, (8),,PG II, D001, CA135, OXIDIZER, HYDROGEN PEROXIDE. ERG # 140, PLOMAB238,1X15DF,CONT#0107,, 28-FEB-2024, CA1170090020, WT/VOL 20 PSP450023D0009SP450024F4191AATS4117
N6247A4073D401CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP05C11EA6810DSOXIDZLP, HO71, UN1493, WASTE SILVER NITRATE, 5.1, PG II, D001 D011, CA 181, OXIDIZER, SOLID, ERG # 140, PLOMAB238,1X2DF,CONT#0109,, , 28-FEB-2024, CA1170090020, WT/VOL 5 PSP450023D0009SP450024F4191AAWN4078
N6247A4073D402CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP05C11EA6810DSOXIDZLP, HO71, UN1449, WASTE BARIUM PEROXIDE, 5.1,(6.1) PG II, D001 D005, CA 181, OXIDIZER, SOLID, ERG # 141, PLOMAB238,1X1DF,CONT#0138,, 12-MAR-2024, CA1170090020, WT/VOL 1 PSP450023D0009SP450024F4191AAWX4078
N6247A4073D403CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP05C11EA6810DSOXIDZLP, HO71, UN1481, WASTE PERCHLORATES,INORGANIC ,NOS (LITHIUM PERCHLORATES , 5.1,PG II, D001, CA 181, OXIDIZER, SOLID, INORGANIC. ERG # 140, PLOMAB238,1X2DF,CONT#0139,, , 12-MAR-2024, CA1170090020, WT/VOL 3 PSP450023D0009SP450024F4191AAXR4078
N6247A4073D404CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP05C11EA6810DSOXIDZLP, HO71, UN1502, WASTE SODIUM PERCHLORATE, 5.1, PG II, D001, 181, OXIDIZER, SOLID. ERG # 140, PLOMAB238,1X1DF,CONT#0141, 12-MAR-2024, CA1170090020, WT/VOL 1 PSP450023D0009SP450024F4191AAYD4078
N6247A4073D405CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP05C11EA6810DSOXIDZLP, HO71, UN1477, WASTE NITRATES ,INORGANIC,NOS (PALLADIUM NITRATE HYDRIDE) 5.1, PG II, D001,CA 181, OXIDIZER, SOLID, INORGANIC. ERG # 140, PLOMAB238,1X1DF,CONT#0140,,, 12-MAR-2024, CA1170090020, WT/VOL 1 PSP450023D0009SP450024F4191AAYK4078
N6247A4073D406CA1170090020412 MSG LGRN63406Mar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP05C11EA6810DSOXIDZLP, HO71, UN1479, WASTE OXIDIZING SOLID,N.O.S. (TETRABUTYLAMMONIUM PERCHLORATE), 5.1, PG II, D001, CA 181, OXIDIZER, SOLID,. ERG # 140, PLOMAB238,1X1DF,CONT#0143,, , 12-MAR-2024, CA1170090020, WT/VOL 1 PSP450023D0009SP450024F4191AAYM4078
N6247A4073D408CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP12C11EA6810DSSOLNOME, HI36, UN1184, WASTE ETHYLENE DICHLORIDE, 3,,(6.1) PG II, D001 U077, CA 214, SOLVENTS, IGNATIBLE, U-LISTED CHEMICALS. ERG # 131, PLOMAB238,1X5DF,CONT#0144,,, 12-MAR-2024, CA1170090020, WT/VOL 10 P,SP450023D0009SP450024F4191ABIL4078
N6247A4073D409CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP07C11EA8970DSFRHMRE0, HR21, UN1415, WASTE LITHIUM 4.3,PG I, D001 D003, CA141, REACTIVE, ELEMENTS METALS, PLOMAB238,1X5DM,CONT#0134,, ERG 138, 12-MAR-2024, CA1170090020, WT/VOL 1 PSP450023D0009SP450024F4191ABIR4078
N6247A4073D410CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP08C11EA6810DSTOXSOL0, LR26, UN1426, WASTE SODIUM BOROHYDRIDE, 4.3, PG I, D001 D003, CA331, - WATER REACTIVE CHEMICALS. ERG # 138, PLOMAB238,1X5DM,CONT#0136,, 12-MAR-2024, CA1170090020, WT/VOL 1 PSP450023D0009SP450024F4191ABIV4078
N6247A4073D411CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP03C11EA6840DSPESTSOL, HI33, UN1869, WASTE MAGNESIUM, 4.1,PG III,, D001, CA 331, IGNITABLE SOLIDS ERG # 138, PLOMAB238,1X5DM,CONT#0137,, , 12-MAR-2024, CA1170090020, WT/VOL 1 PSP450023D0009SP450024F4191ABIZ4078
N6247A4073D412CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentRX97T21EA6810DSTOXLIQ0, HR71, UN1992, RQ WASTE FLAMMABLE LIQUIDS,TOXIC,N.O.S.(CYANIDE,MINERAL SPIRITS), 3, (6.1), PG II, D001 D003 D006 D008 D018, CA 342, (OTTO FUEL) TORPEDO MAINTANCE; DEFUELING AND CLEANING ERG # 131, PLOMAB238,1XTOTE,(RQ D001,D018), 12-MAR-2024, CA1170090020, WT/VOL 2424 PSP450023D0009SP450024F4191ABJB4078
N6247A4073D407CA1170090020412 MSG LGRN6247AMar 18, 2024Mar 19, 2024HWAuthorized for PaymentLP05C11EA6810DSOXIDZLP, HO71, UN1514, RQ WASTE ZINC NITRATE, 5.1, PG II, D001, CA 181, OXIDIZER, SOLID, . ERG # 140, PLOMAB238,1X1DF,CONT#0142,, , 12-MAR-2024, CA1170090020, WT/VOL 1 PSP450023D0009SP450024F4191ABJG4078
N6247A4144D100CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP14C411EA8010DSOILPAIN, HI10, UN3469, WASTE PAINT RELATED MATERIAL,FLAMMABLE,CORROSIVE, 3,(8), PGII, D001, CA461, PAINTS,LIQUID,IGNITABLE,SOLVENT BASE,CORROSIVE (WITH AMINES). ERG # 132, NAVSTB332, 11X55 DF, BAY 10 CONT# 0628, 0669, 0713, 0647, 0745, 0818, 0842, 0841, 0864, 0884, 0902 (RQ D001), ASD, 26-MAR-2024, CA6170024289, WT/VOL 1917 P, Constituents Silver Nickel Vanadium Ethyl Benzene Methylene Chloride Naphthalene Toluene Xylenes AntimonySP450023D0009SP450024F6992AAMP4177
N6247A4144D101CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP03C410EA8030DSPRVCMPF, HI13, UN1133, WASTE ADHESIVE, 3, PGII, D001 D005 D007 D008 D011 D022 D035, 281, ADHESIVES, IGNITABLE. ERG # 128, NAVSTB332, 10X55 DF, BAY 10 CONT# 0592, 0574, 0680, 0712, 0698, 0697, 0812, 0867, 0909, 0970 (RQ D001), ASD, 19-MAR-2024, CA6170024289, WT/VOL 1947 P, UHC(s) Acetone Diethyl phthlate Methanol Naphthalene Isobutyl alcohol Toluene 1,1,1-Trichloroethane Xylenes-mixed isomers( Ethyl benzeneSP450023D0009SP450024F6992AAMY4177
N6247A4144D102CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP14C47EA8010DSOILPAIN, HI10, UN3469, WASTE PAINT RELATED MATERIAL,FLAMMABLE,CORROSIVE, 3,(8), PGII, D001, CA461, PAINTS,LIQUID,IGNITABLE,SOLVENT BASE,CORROSIVE (WITH AMINES). ERG # 132, NAVSTB332, 7X55 DM, BAY 9 CONT# 1711, 1710, 1741, 1739, 1981, 1991, 1990 (RQ D001), ASD, 05-SEP-2023, CA6170024289, WT/VOL 1756 P, Constituents Silver Nickel Vanadium Ethyl Benzene Methylene Chloride Naphthalene Toluene Xylenes AntimonySP450023D0009SP450024F6992AANF4177
N6247A4144D103CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP03C412EA8030DSPRVCMPF, HI13, UN1133, WASTE ADHESIVE, 3, PGII, D001 D005 D007 D008 D011 D022 D035, CA281, ADHESIVES, IGNITABLE. ERG # 128, NAVSTB332, 12X55 DM, BAY 3 CONT# 0738, 1740, 1716, 1715, 1712, 1713, 1738, 1708, 1709, 2233, 1980, 1979 (RQ D001), ASD, 05-SEP-2023, CA6170024289, WT/VOL 2150 P, UHC(s) Acetone Diethyl phthlate Methanol Naphthalene Isobutyl alcohol Toluene 1,1,1-Trichloroethane Xylenes-mixed isomers( Ethyl benzeneSP450023D0009SP450024F6992AANP4177
N6247A4144D106CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentTX21C41EA8010DSPNTMETH, HS51, UN2810, WASTE TOXIC, LIQUIDS, ORGANIC, N.O.S. (METHYLENE CHLORIDE), 6.1, PGIII, D005 D006 D007 D008 D022 F001 F002, CA741, SOLVENTS, TOXIC, SPENT METHYLENE CHLORIDE. ERG # 153, NAVSTB332, 1X55 DF, CONT# 2009 BAY 1 (RQ F002), ASD, 31-OCT-2023, CA6170024289, WT/VOL 461 P, UHC(s) Acetone Lead Methylene chloride 1,1-Dichloroethane Antimony Silver ThalliumSP450023D0009SP450024F6992AAQN4177
N6247A4144D105CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentTX07C42EA9999DSLISTDEB, HT46, NA3077, HAZARDOUS WASTE SOLID N.O.S. (METHYLENE CHLORIDE, METHYL ETHYL KETONE), 9, PGIII, D005 D006 D007 D008 D010 D022 D035 F002 F005, CA751, DEBRIS, SOLVENT, TOXIC LISTED C/W METHYLENE CHLORIDE. ERG # 171, NAVSTB332, 2X55 DF, BAY 1 CONT# 1793, 1982 (RQ F002), ASD, 19-SEP-2023, CA6170024289, WT/VOL 237 P, UHC(s) Lead Antimony Silver Thallium Vanadium Methylene chloride Acetone Chloromethane (methyl chloride) Methyl ethyl ketone 1,1,2-Trichloro-1,2,2-trifluorethane Butyl benzyl phthalate 1,1-Dichloroethane Methyl isobutyl ketone Phenol Xylenes-mixed isomersSP450023D0009SP450024F6992AAWB4177
N6247A4144D107CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentTX21C41EA8010DSPNTMETH, HS51, UN2810, WASTE TOXIC, LIQUIDS, ORGANIC, N.O.S. (METHYLENE CHLORIDE), 6.1, PGIII, D005 D006 D007 D008 D022 F001 F002, CA741, SOLVENTS, TOXIC, SPENT METHYLENE CHLORIDE. ERG # 153, NAVSTB332, 1X55 DF, BAY 1, CONT# 1821 (RQ F002), ASD, 19-SEP-2023, CA6170024289, WT/VOL 301 P, UHC(s) Acetone Lead Methylene chloride 1,1-Dichloroethane Antimony Silver ThalliumSP450023D0009SP450024F6992AAWJ4177
N6247A4144D110CA6170024289NAVAL STATION SAN DIEGON00245Jun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP06C11EA6810DSORGPERO, HO51, UN3105, WASTE ORGANIC PEROXIDE TYPE D, LIQUID (METHYL ETHYL KETONE PEROXIDE, 35%), 5.2, PGII, D001 D003 D035 U160, CA331, ORGANIC PEROXIDE, NAVSTB332, 1X1 DF, BAY6, CONT# 1988, ASD, 02-NOV-2023, CA6170024289, WT/VOL 1 PSP450023D0009SP450024F6992AAWY4177
N6247A4144D113CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP05C31EA6810DSOXIDZLP, HO72, UN1493, WASTE SILVER NITRATE, 5.1, PGII, D006 D007 D008 D011, CA141, OXIDIZING LIQUID, NAVSTB332, 1X30 DF, BAY 6, CONT# 1733, ASD, 05-SEP-2023, CA6170024289, WT/VOL 44 PSP450023D0009SP450024F6992AAXC4177
N6247A4144D114CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP05C31EA6810DSOXIDZLP, HO71, UN2468, WASTE TRICHLOROISOCYANURIC ACID, DRY, 5.1, PGII, D003 D005 D006 D007 D008 D011, CA181, OXIDIZER, SOLID, INORGANIC. ERG # 140, NAVSTB332, 1X30 DF, BAY 6, CONT# 1983, ASD, 02-NOV-2023, CA6170024289, WT/VOL 19 PSP450023D0009SP450024F6992AAXD4177
N6247A4144D115CA6170090017NAVAL AIR STATION EL CENTRON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP05C11EA6850DSCHROMES, HO21, UN1463, WASTE CHROMIUM TRIOXIDE, ANHYDROUS, 5.1, (6.1, 8), PGII, D001 D007, CA181, OXIDIZER, CHROMIC ACID (SOLID). ERG # 141, NAVSTB332, 1X5 DF, BAY 6, CONT# 1735, ASD, 05-SEP-2023, CA6170090017, WT/VOL 16 PSP450023D0009SP450024F6992AAXG4177
N6247A4144D117CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentFL13C41EA6810DSOXIDZLP, HO72, UN3139, WASTE OXIDIZING LIQUID, N.O.S. (SODIUM HYDROXIDE, SODIUM PERMANGANATE), 5.1, PGII, D001 D006 D007 D008, CA141, OXIDIZING LIQUID, NAVSTB332, 1X55 DF, BAY 6, CONT# 1736, ASD, 05-SEP-2023, CA6170024289, WT/VOL 615 PSP450023D0009SP450024F6992AAXI4177
N6247A4144D118CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP05C21EA6810DSOXIDZLP, HO71, UN1498, WASTE SODIUM NITRATE, 5.1, PGII, D001 D005 D006 D007 D008 D011, CA181, OXIDIZER, SOLID, INORGANIC. ERG # 140, NAVSTB332, 1X15 DF, BAY 6, CONT# 1986, ASD, 21-MAY-2024, CA6170024289, WT/VOL 40 PSP450023D0009SP450024F6992AAXK4177
N6247A4144D119CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP05C41EA6810DSOXIDZLP, HO71, UN1479, WASTE OXIDIZING SOLID,N.O.S. (SODIUM PERBORATE), 5.1, PGII, D001 D005 D006 D007 D008 D011, CA181, OXIDIZER, SOLID, INORGANIC. ERG # 140, NAVSTB332, 1X55 DF, BAY6, CONT# 1971, ASD, 16-OCT-2023, CA6170024289, WT/VOL 84 PSP450023D0009SP450024F6992AAXL4177
N6247A4144D120CA6170024289NAVAL STATION SAN DIEGON6247AJun 25, 2024Jun 27, 2024HWAuthorized for PaymentLP05C418EA6810DSOXIDZLP, HO41, UN2014, WASTE HYDROGEN PEROXIDE AQUEOUS SOLUTION, 5.1, (8), PGII, D001, CA135, OXIDIZER, HYDROGEN PEROXIDE. ERG # 140, NAVSTB332, 19X55 DF, BAY 6, CONT#0987, 0988, 0989, 0990, 0991, 0992, 0993, 0994, 0995, 0996, 0997, 0998, 0999, 1000, 1001, 1002, 1389, 1705, 0201 (RQ D001), ASD, 28-JUL-2023, CA6170024289, WT/VOL 3188 PSP450023D0009SP450024F6992AAXW4177
N6247A4144D122CA6170024289NAVAL STATION SAN DIEGON6247AJun 26, 2024Jun 27, 2024HWAuthorized for PaymentLP05C31EA6810DSOXIDZLP, HO41, UN2014, WASTE HYDROGEN PEROXIDE AQUEOUS SOLUTION, 5.1, (8), PGII, D001, CA135, OXIDIZER, HYDROGEN PEROXIDE. ERG # 140, NAVSTB332, 1X30 DF, BAY 6, CONT# 1737, ASD, 05-SEP-2023, CA6170024289, WT/VOL 64 PSP450023D0009SP450024F6992AAFR4178
N6247A4144D124CA6170024289NAVAL STATION SAN DIEGON6247AJun 26, 2024Jun 27, 2024HWAuthorized for PaymentLP05C38EA6810DSOXIDZLP, HO71, UN1479, WASTE OXIDIZING SOLID,N.O.S. (SODIUM POTASSIUM NITRATE), 5.1, PGII, D001 D005 D006 D007 D008 D011, CA181, OXIDIZER, SOLID, INORGANIC. ERG # 140, NAVSTB332, 8X30 DF, BAY 6, CONT# 0196, 0199, 0195, 0198, 0197, 0193, 0194, 0200 (RQ D001), ASD, 26-JAN-2024, CA6170024289, WT/VOL 3387 PSP450023D0009SP450024F6992AAGC4178
N6247A4144D125CA6170024289NAVAL STATION SAN DIEGON6247AJun 26, 2024Jun 27, 2024HWAuthorized for PaymentLP05C31EA6810DSOXIDZLP, HO71, UN1479, WASTE OXIDIZING SOLID,N.O.S. (SODIUM CHLORATE, POTASSIUM CHLORATE), 5.1, PGII, D001 D005 D006 D007 D008 D011, CA181, OXIDIZER, SOLID, INORGANIC. ERG # 140, NAVSTB332, 1X30 DF, BAY 6, CONT# 1734, ASD, 05-SEP-2023, CA6170024289, WT/VOL 81 PSP450023D0009SP450024F6992AAGF4178
N6247A4144D121CA6170024289NAVAL STATION SAN DIEGON6247AJun 26, 2024Jun 27, 2024HWAuthorized for PaymentLP05C31EA6810DSOXIDZLP, HO71, UN3087, WASTE OXIDIZING SOLID,N.O.S. (SODIUM DICHROMATE DIHYDRATE), 5.1, (6.1, PGII, D001 D005 D006 D007 D008 D011, CA181, OXIDIZER, SOLID, INORGANIC. ERG # 140, NAVSTB332, 1X30 DF, BAY 6, CONT# 1987, ASD, 23-NOV-2023, CA6170024289, WT/VOL 57 PSP450023D0009SP450024F6992AAIL4178
N6247A4193L100CA3170024381ENV MGT DIV HAZ WASTE DEPTN63042Jul 15, 2024Jul 16, 2024HWAuthorized for PaymentLP03C11EA6810DSHMFLAML, LEMR061, UN1219, WASTE ISOPROPYL ALCOHOL, 3, II, D001, ISOPROPYL ALCOHOL, 1X5G, DF, 06-Jun-2024, CA3170024381, 5120 45 7 P, WT/VOL, Constituents ISOPROPYL ALCOHOL 50 - 75%SP450023D0009SP450024F7446AASK4197
N6247A4193L101CA3170024381ENV MGT DIV HAZ WASTE DEPTN63042Jul 15, 2024Jul 16, 2024HWAuthorized for PaymentFL16C41EA8010DSPAINTFL, LEMR084, RQ, UN1263, WASTE PAINT RELATED MATERIAL, 3, II, D001 D007 D005 D008 D035, 331, FLAMMABLE PAINT, 1X55G, DM, 17-Jun-2024, CA3170024381, 4756 45 112 P, WT/VOL 112 P, Constituents HEPTAN-2-ONE 10 - 30% SILICA GEL 7 - 13% METHYL ACETATE 10 - 20% METHYL AMYL KETONE 10 - 20% TITANIUM DIOXIDE 10 - 20% HEXAMETHYLENE DIISOCYANATE 10 - 20% XYLENE .1 - 1%SP450023D0009SP450024F7446AASM4197
N6247A4193L102CA3170024381ENV MGT DIV HAZ WASTE DEPTN63042Jul 15, 2024Jul 16, 2024HWAuthorized for PaymentFL16C34EA8010DSPAINTFL, LEMR084, RQ, UN1263, WASTE PAINT RELATED MATERIAL, 3, II, D001 D007 D005 D008 D035, 331, FLAMMABLE PAINT, 4X30G, DM, 06-Jun-2024, CA3170024381, 4895 45 65 P 5211 45 68 P 5126 45 66 P 5262 45 89 P, WT/VOL 288 P, Constituents HEPTAN-2-ONE 10 - 30% SILICA GEL 7 - 13% METHYL ACETATE 10 - 20% METHYL AMYL KETONE 10 - 20% TITANIUM DIOXIDE 10 - 20% HEXAMETHYLENE DIISOCYANATE 10 - 20% XYLENE .1 - 1%SP450023D0009SP450024F7446AASN4197
N6247A4193L103CA3170024381ENV MGT DIV HAZ WASTE DEPTN63042Jul 15, 2024Jul 16, 2024HWAuthorized for PaymentFL16C61EA8010DSPAINTFL, LEMR084, RQ, UN1263, WASTE PAINT RELATED MATERIAL, 3, II, D001 D007 D005 D008 D035, 331, 1 TRIWALL, CF, 07-May-2024, WT/VOL 720 P, Constituents HEPTAN-2-ONE 10 - 30% SILICA GEL 7 - 13% METHYL ACETATE 10 - 20% METHYL AMYL KETONE 10 - 20% TITANIUM DIOXIDE 10 - 20% HEXAMETHYLENE DIISOCYANATE 10 - 20% XYLENE .1 - 1%SP450023D0009SP450024F7446AASQ4197

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .