This document contains technical specifications for the purchase of 15 high-pressure washers by the Maine Department of Transportation (Maine DOT). The equipment specified is an oil-fired, electric motor-powered high-pressure washer with the Alkota Model 216AX4 listed as the preferred unit or approved equivalent. Key specifications include a discharge volume of 2.0 gallons per minute, pump head pressure of 1600 psi, a temperature rise of 120°F at 2.0 gallons per minute with a maximum temperature limit of 210°F, and combustion smoke ratings at Bacharach Scale #1 or #2 with allowed carbon monoxide levels of 0.01%. The equipment must include a four-wheeled cart, 4.5-gallon fuel tank, eight-inch stack, spray tips and nozzles, 115v 60 Hz 2.3hp single-phase electric motor, 50 feet of high-pressure hose, trigger gun, spray wand, and electrical power cord. All bids must include shipping and delivery to Maine DOT Fleet Services in Scarborough, Maine, with the vendor subject to pre-inspection before delivery.
Vendors must submit complete parts and service manuals with each unit, with CD format acceptable, and may be requested to provide training within eight weeks of delivery at the vendor's expense. The warranty requirement specifies one year on parts and labor with seven years on the heating coil, or the manufacturer's standard warranty, whichever is greater. Bids will be evaluated based on price, warranty, manufacturer's performance data, delivery schedule, parts availability, and other relevant factors deemed appropriate by Maine DOT. All necessary documentation including invoices must accompany delivery, and any exceptions to the stated specifications must be clearly identified on a separate document submitted with the bid proposal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation_terms[1].doc | DOC document | |
| Questions and Answers.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HIGH PRESSURE WASHER
Specifications
Purposes and Intent
The following specifications are intended to describe an oil fired high pressure washer that is electric motor powered. Alkota Model 216AX4 preferred (or approved equal).
1. Specifications to include:
· Discharge Volume of 2.0 gallons per minute.
· Pump Head Pressure of 1600 psi.
· Temperature Rise of 120° F @ 2.0 gallons per minute.
· Temperature Limit 210° F.
· Combustion Smoke / Bacharach Scale # 1 or # 2smoke.
· Allowed levels of carbon monoxide to be 0.01 %
2. Features to include:
· Four wheeled cart.
· Four and one half (4.5) gallon fuel tank.
· Eight (8) inch Stack (OD).
· Spray tips / nozzles.
· 115v 60 Hz 2.3hp single ph electric motor.
· Fifty (50) ft of high pressure hose.
· Trigger gun.
· Spray wand.
· Electrical power cord.
GENERAL INFORMATION:
1.
All bid proposals will include shipping and delivery to:
Maine DOT Fleet Services, 61 Pleasant Hill Road Scarborough, Maine, 04074.
2.
Maine DOT reserves the right to pre-inspect the equipment before delivery.
3.
Upon delivery of unit or units all necessary paper work such as invoices shall accompany unit(s).
4. One (1) complete parts manual shall be supplied per unit (CD’s are ok).
5. One (1) complete service manual shall be supplied per unit (CD’s are ok).
6.
Vendor may be asked to provide training at a later date, but within eight (8) weeks of delivery.
7.
Be it known that these specifications are a minimum and that bids will be evaluated based on price, warranty, manufacturer’s performance data, delivery schedule, parts availability and other items deemed appropriate.
WARRANTY:
1. One year on parts and labor and seven (7) years on the heating coil, or manufacturer’s standard warranty which ever one is greater.
EXCEPTIONS:
Exceptions to specifications shall be listed on a separate paper, noted as exceptions and submitted with bid proposal. If exceptions are not listed as such it shall be considered that the vendor will comply with all specifications as listed.
REV
9/12/11
ESB