This document is a set of architectural and construction drawings for the Parks and Recreation Washington Square Addition project in York County, Virginia. The project aims to expand an existing Parks and Recreation rented space by annexing and constructing several offices and spaces within a designated zone at 5338-E George Washington Memorial Highway, Yorktown, Virginia. The scope of work includes general demolition, framing construction, electrical installation, mechanical systems, and finishes. The project includes two main work areas (Area A and Area B) with approximately 810 square feet of building addition and multiple new office spaces, restrooms, conference rooms, and storage areas. Key materials and specifications are detailed across 13 sheets of construction drawings, including floor plans, reflected ceiling plans, electrical plans, HVAC plans, and mechanical details. The project incorporates new light fixtures, electrical receptacles, exit and emergency lighting, supply and return diffusers, and ductwork. York County will waive all permit fees for local building permits, with the contractor responsible for any additional permits such as LDA or VSPM. The contractor must submit material submittals for owner approval prior to commencing work and must comply with the 2018 Virginia Construction Code, 2021 Virginia Uniform Statewide Building Code, 2017 Virginia Electrical Code, and applicable NFPA and ASTM standards.
The project specifications detail specific products and manufacturers, including Lithonia Lighting fixtures, Panasonic exhaust fans, Titus diffusers, Pure Performance paint, and Armstrong ceiling tiles, with approved equal alternatives permitted. The contractor is responsible for all material purchases and installations unless explicitly marked as "owner provided" or "third party installed." Drywall finishes must meet Level 4 standards with two coats of primer and two coats of paint on all new and existing walls and door frames in Dover White color. The contractor must remove and dispose of all demolished materials, with such material becoming contractor property unless otherwise noted. The project requires careful coordination to avoid disrupting services in occupied adjacent areas, with contractors required to notify the owner 24-48 hours prior to any entrance or hallway closures. An air balance test must be conducted in compliance with SMACNA standards, with final reports provided to the owner. The revised final design was dated May 13, 2026, with previous revision dates of April 2, 2026, and April 23, 2026. Specific provisions address ADA compliance for door approaches and clearances, electrical panel schedules, and life safety requirements including Knox Box installation by the owner and permanent occupancy load signage.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation, IFB B130250-VR, Parks & Recreation Office Renovation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PARKS AND RECREATION - WASHINGTON SQUARE ADDITION
TE
T
E
T E
E
OS
## AFF
Y O
R K
C O
U N
T Y
SE
R
V
IC
E D
R
IV
E
PO
ST
O
FF
IC
E B
O X
Y O
R K
T O
W N
, V
IR
G
IN
IA
0-
(7
) 8
-3
FA
X : 8
-3
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
PM
AutoCAD SHX Text
AutoCAD SHX Text G-001
AutoCAD SHX Text Revisions/Comments/Notes
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text
5338-E GEORGE WASHINGTON MEMORIAL HIGHWAY YORKTOWN, VA 23692
AutoCAD SHX Text PROJECT NARRATIVE: THIS PROJECT AIMS TO EXPAND AN EXISTING AREA WITHIN THE PARKS AND RECREATION RENTED SPACE BY ANNEXING AND/OR CONSTRUCTING SEVERAL OFFICES AND SPACES IN THE DESIGNATED ZONE.
AutoCAD SHX Text
PARKS AND RECREATION WASHINGTON SQUARE ADDITION COVER SHEET
AutoCAD SHX Text
IDENTIFIED AREA OF WORK TO BE COMPLETED
AutoCAD SHX Text
DUMPSTER, PORTAJOHN, AND LAYDOWN LOCATION
AutoCAD SHX Text ABBREVIATIONS AFF - ABOVE FINISHED FLOOR ASHRAE - AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR-CONDITIONING ENGINEERS BLDG - BUILDING CFM - CUBIC FEET PER MINUTE FLS - FIRE AND LIFE SAFETY LF - LINEAR FEET SF - SQUARE FEET SMACNA - SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION TYP - TYPICAL
AutoCAD SHX Text LEGENDS HVAC LEGEND SUPPLY DIFFUSER RETURN DIFFUSER AIR FLOW FLEX DUCT HEAT PUMP EXISTING THERMOSTAT EXHAUST FAN
AutoCAD SHX Text ELECTRICAL LEGEND LIGHT FIXTURES OCCUPANCY SENSOR FIRE EXTINGUISHER EXIT SIGN W/ DIRECTIONAL ARROW EMERGENCY LIGHT NEW RECEPTACLE EXISTING RECEPTACLE NEW LIGHT SWITCH EXISTING LIGHT SWITCH DATA OUTLET NEW/EXIST. DATA OUTLET ABOVE FINISHED FLOOR ELECTRICAL WIRING
AutoCAD SHX Text
GENERAL LEGEND DEMO HANGING CEILING PROJECT AREA
AutoCAD SHX Text INDEX OF DRAWINGS G - 001 COVER SHEET COVER SHEET G - 002 GENERAL NOTES AND SCHEDULE GENERAL NOTES AND SCHEDULE G - 003 GENERAL NOTES AND SPECS GENERAL NOTES AND SPECS A - 101 FLOOR PLAN - DEMO FLOOR PLAN - DEMO A - 102 FLOOR PLAN - CONSTRUCTION FLOOR PLAN - CONSTRUCTION A - 103 REFLECTED CEILING PLAN - DEMO REFLECTED CEILING PLAN - DEMO A - 104 REFLECTED CEILING PLAN - CONSTRUCTION REFLECTED CEILING PLAN - CONSTRUCTION A - 105 DETAILS DETAILS E - 101 FLOOR PLAN - POWER DEMO FLOOR PLAN - POWER DEMO E - 102 FLOOR PLAN - POWER CONSTRUCTION FLOOR PLAN - POWER CONSTRUCTION M - 101 REFLECTED CEILING PLAN - HVAC DEMO REFLECTED CEILING PLAN - HVAC DEMO M - 102 REFLECTED CEILING PLAN - HVAC CONSTRUCTION REFLECTED CEILING PLAN - HVAC CONSTRUCTION M - 103 MECHANICAL DETAILS MECHANICAL DETAILS F - 101 LIFE SAFETY PLAN
AutoCAD SHX Text
KEY PLAN NOT TO SCALE
AutoCAD SHX Text
PROJECT AREA
AutoCAD SHX Text
VICINITY MAP NOT TO SCALE
AutoCAD SHX Text N
AutoCAD SHX Text
ELECTRICAL BOX
AutoCAD SHX Text Closet 5 SF
AutoCAD SHX Text
DEPT. OF PUBLIC WORKS
AutoCAD SHX Text 05/13/2026
AutoCAD SHX Text Initial Preliminary Design
AutoCAD SHX Text 4/2/26
AutoCAD SHX Text
AutoCAD SHX Text Revised Preliminary Design
AutoCAD SHX Text 4/23/26
AutoCAD SHX Text
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA A
AutoCAD SHX Text Revised Final Design
AutoCAD SHX Text 5/13/26
AutoCAD SHX Text
Y O
R K
C O
U N
T Y
SE
R
V
IC
E D
R
IV
E
PO
ST
O
FF
IC
E B
O X
Y O
R K
T O
W N
, V
IR
G
IN
IA
0-
(7
) 8
-3
FA
X : 8
-3
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
PM
AutoCAD SHX Text
AutoCAD SHX Text Revisions/Comments/Notes
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text GENERAL NOTES (ALL SHEETS): 1. THE OWNER SHALL WAIVE ALL PERMIT FEES FOR YORK COUNTY BUILDING PERMITS (PLUMBING, ELECTRICAL, BUILDING, THE OWNER SHALL WAIVE ALL PERMIT FEES FOR YORK COUNTY BUILDING PERMITS (PLUMBING, ELECTRICAL, BUILDING, MECHANICAL, ETC.). ANY ADDITIONAL PERMITS (LDA, VSPM, ETC.) SHALL BE PAID FOR BY THE CONTRACTOR. 2. CONTRACTOR TO SUBMIT MATERIAL SUBMITTALS AND ASSOCIATED INFORMATION FOR APPROVAL TO THE OWNER PRIOR TO CONTRACTOR TO SUBMIT MATERIAL SUBMITTALS AND ASSOCIATED INFORMATION FOR APPROVAL TO THE OWNER PRIOR TO COMMENCING THE WORK WITHIN THE PROJECT AREA. 3. ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND APPLICABLE CODES AS CURRENTLY ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND APPLICABLE CODES AS CURRENTLY ENFORCED IN THE COUNTY OF YORK AND/OR WITHIN THE STATE OF VIRGINIA. 4. ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN THE PROJECT AREA. ALL ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN THE PROJECT AREA. ALL BLACK/DARK LINE WORK THROUGHOUT THIS PLAN INDICATE ITEMS TO BE DEMOLISHED OR ADDED FOR CONSTRUCTION WITHIN THE PROJECT AREA. 5. THE CONTRACTOR IS RESPONSIBLE FOR THE PURCHASE AND INSTALLATION OF ALL ITEMS LISTED IN THE DRAWING PACKAGE THE CONTRACTOR IS RESPONSIBLE FOR THE PURCHASE AND INSTALLATION OF ALL ITEMS LISTED IN THE DRAWING PACKAGE UNLESS CLEARLY MARKED AS "OWNER PROVIDED," OWNER," AND "THIRD PARTY INSTALLED." IN SOME CASES THE CONTRACTOR IS REQUIRED TO INSTALL OWNER PROVIDED EQUIPMENT AND SYSTEMS. 6. ALL ITEMS SUPPLIED TO THE CONTRACTOR BY THE OWNER WILL BECOME THE RESPONSIBILITY OF THE CONTRACTOR UPON ALL ITEMS SUPPLIED TO THE CONTRACTOR BY THE OWNER WILL BECOME THE RESPONSIBILITY OF THE CONTRACTOR UPON DELIVERY OF THOSE ITEMS. ANY DAMAGE NOT IDENTIFIED TO THE OWNER AFTER DELIVERY OR DAMAGE THAT OCCURS THEREAFTER IS THE CONTRACTORS RESPONSIBILITY. 7. CONTRACTOR TO REMOVE AND DISPOSE OF ALL RELATED MATERIAL SHOWN AS DEMOLISHED THROUGHOUT THE PLANS, UNLESS CONTRACTOR TO REMOVE AND DISPOSE OF ALL RELATED MATERIAL SHOWN AS DEMOLISHED THROUGHOUT THE PLANS, UNLESS OTHERWISE NOTIFIED TO SALVAGE TO THE OWNER. ALL MATERIAL AND EQUIPMENT SUBJECT TO BE REMOVED BECOMES PROPERTY OF THE CONTRACTOR, UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PROPERLY DISPOSE OF ALL SUCH MATERIAL AND EQUIPMENT OFF SITE. 8. SPACE NAME'S (OFFICES, HALLWAYS, RESTROOMS, ETC.) WITHIN THE PROJECT AREA AND SPECIFIED ON THE PLANS, MAY NOT SPACE NAME'S (OFFICES, HALLWAYS, RESTROOMS, ETC.) WITHIN THE PROJECT AREA AND SPECIFIED ON THE PLANS, MAY NOT MATCH WHAT IS SHOWN ON SITE. THE NAMES SHOWN ON THE CONTRACT DOCUMENTS ARE USED FOR CLARIFICATION. 9. EXISTING ELECTRICAL PANEL SCHEDULES HAVE NOT BEEN CONFIRMED FOR ACCURACY; AS SUCH, THEY MAY CONTAIN EXISTING ELECTRICAL PANEL SCHEDULES HAVE NOT BEEN CONFIRMED FOR ACCURACY; AS SUCH, THEY MAY CONTAIN OUTDATED OR MISSING INFORMATION. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL ELECTRICAL INFORMATION AT NO ADDITIONAL COST TO THE COUNTY. GENERAL NOTES - SURROUNDING AREAS (ALL SHEETS): 1. CONTRACTOR TO TAKE CARE AS TO NOT DISRUPT SERVICES IN OTHER AREAS/PARTS OF THE BUILDING OR THE SURROUNDING CONTRACTOR TO TAKE CARE AS TO NOT DISRUPT SERVICES IN OTHER AREAS/PARTS OF THE BUILDING OR THE SURROUNDING OFFICE SPACES. THE REMOVAL, RELOCATION, AND/OR ADDITION OF A CIRCUIT, UTILITY, OR ITEM MAY DISRUPT POWER, LIGHTING, COMMUNICATION/DATA, FIRE SYSTEMS, OR SOME OTHER SERVICE IN OCCUPIED PORTIONS OF THE BUILDING. PLEASE NOTIFY THE OWNER PRIOR TO COMMENCING SUCH WORK. . 2. CONTRACTOR TO ENSURE THAT THE HALLWAY AND ANY OTHER ENTRANCES TO THE PROJECT SHALL BE KEPT CLEAR OF CONTRACTOR TO ENSURE THAT THE HALLWAY AND ANY OTHER ENTRANCES TO THE PROJECT SHALL BE KEPT CLEAR OF HALLWAY AND ANY OTHER ENTRANCES TO THE PROJECT SHALL BE KEPT CLEAR OF DEBRIS, EQUIPMENT, AND MATERIAL. CONTRACTOR TO SWEEP AND CLEAN, AS NEEDED, THROUGHOUT THE DAY AND MOST IMPORTANTLY, AT THE END OF EACH DAY. 3. IF CLOSURE OF ENTRANCE(S) OR HALLWAY(S) IS REQUIRED, CONTRACTOR TO INFORM THE OWNER 24-48 HOURS PRIOR. IF CLOSURE OF ENTRANCE(S) OR HALLWAY(S) IS REQUIRED, CONTRACTOR TO INFORM THE OWNER 24-48 HOURS PRIOR. CONTRACTOR TO COORDINATE WITH THE OWNER IN ADVANCE TO ENSURE THAT SURROUNDING OFFICES AND/OR EMPLOYEES ARE MADE AWARE OF SUCH INSTANCES. ALL APPLICABLE CODES THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE LAWS AND BUILDING CODES GOVERNING THIS PROJECT. WHERE LAWS AND CODES ARE IN DIRECT CONFLICT, THE MORE STRINGENT REQUIREMENTS SHALL PREVAIL. SUCH COMPLIANCE SHALL INCLUDE, BUT NOT LIMITED TO THE LATEST ADOPTION VERSIONS OF: 1. 2018 VIRGINIA CONSTRUCTION CODE (VCC) 2018 VIRGINIA CONSTRUCTION CODE (VCC) 2. 2018 VIRGINIA MECHANICAL CODE 2018 VIRGINIA MECHANICAL CODE 3. 2018 VIRGINIA PLUMBING CODE 2018 VIRGINIA PLUMBING CODE 4. 2021 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) 2021 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) 5. 2018 VIRGINIA ENERGY CONSERVATION AND ENVIRONMENTAL STANDARD (VEES) 2018 VIRGINIA ENERGY CONSERVATION AND ENVIRONMENTAL STANDARD (VEES) 6. 2017 VIRGINIA ELECTRICAL CODE 2017 VIRGINIA ELECTRICAL CODE 7. 2017 ICC A117.1-2017 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2017 ICC A117.1-2017 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 8. 2017 NATIONAL ELECTRICAL CODE (NPFA 70) 2017 NATIONAL ELECTRICAL CODE (NPFA 70) 9. 2016 NATIONAL FIRE ALARM AND SIGNALING CODE (NFPA 72) 2016 NATIONAL FIRE ALARM AND SIGNALING CODE (NFPA 72) 10. 2010 AMERICANS WITH DISABILITIES ACT (ASD) 2010 AMERICANS WITH DISABILITIES ACT (ASD) 11. ACI STANDARD 530-13 "BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES" ACI STANDARD 530-13 "BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES" 12. OSHA, OCCUPATIONAL SAFETY AND HEALTH REGULATIONS OSHA, OCCUPATIONAL SAFETY AND HEALTH REGULATIONS 13. ASTM STANDARDS IN BUILDING CODES, VOLUME I AND II, LATEST EDITION ASTM STANDARDS IN BUILDING CODES, VOLUME I AND II, LATEST EDITION WALL FINISHING GENERAL NOTES (ALL SHEETS): 1. FOR ALL INFORMATION REGARDING BRAND, TYPE, AND COLOR REFER TO THE "PROJECT SPECIFICATIONS" ON SHEET G-002 FOR FOR ALL INFORMATION REGARDING BRAND, TYPE, AND COLOR REFER TO THE "PROJECT SPECIFICATIONS" ON SHEET G-002 FOR DETAILED PRODUCT INFORMATION. 2. CONTRACTOR TO PROVIDE LEVEL 4 DRYWALL FINISH. ALL CONNECTIONS POINTS BETWEEN THE NEW AND EXISTING DRYWALL TO CONTRACTOR TO PROVIDE LEVEL 4 DRYWALL FINISH. ALL CONNECTIONS POINTS BETWEEN THE NEW AND EXISTING DRYWALL TO BE TAPED, MUDDED, AND SMOOTHED TO MEET LEVEL 4 DRYWALL FINISHING STANDARDS. 3. CONTRACTOR SHALL PATCH AND DRYWALL ALL NEW WALLS. THESE WALLS MUST BE PATCHED, DRYWALLED, POINTED UP, CONTRACTOR SHALL PATCH AND DRYWALL ALL NEW WALLS. THESE WALLS MUST BE PATCHED, DRYWALLED, POINTED UP, PRIMED, AND PAINTED UNLESS OTHERWISE SPECIFIED WITHIN THE CONSTRUCTION PLANS. WALL FINISHING INCLUDES INSTALLATION OF RECEPTACLE/LIGHT SWITCH COVERS AS REQUIRED. 3.1. NEW AND EXISTING WALLS: NEW AND EXISTING WALLS: 3.1.1. TO RECEIVE TWO (2) COATS OF PRIMER. TO RECEIVE TWO (2) COATS OF PRIMER. 3.1.2. TO RECEIVE TWO (2) COATS OF PAINT. TO RECEIVE TWO (2) COATS OF PAINT. 4. CONTRACTOR SHALL PRIME AND PAINT ALL NEW AND EXISTING DOOR FRAMES UNLESS OTHERWISE SPECIFIED WITHIN THE CONTRACTOR SHALL PRIME AND PAINT ALL NEW AND EXISTING DOOR FRAMES UNLESS OTHERWISE SPECIFIED WITHIN THE CONSTRUCTION PLANS. 4.1. NEW AND EXISTING DOOR FRAMES: NEW AND EXISTING DOOR FRAMES: 4.1.1. TO RECEIVE TWO (2) COATS OF PRIMER. TO RECEIVE TWO (2) COATS OF PRIMER. 4.1.2. TO RECEIVE TWO (2) COATS OF PAINT. TO RECEIVE TWO (2) COATS OF PAINT. 5. AFTER THE FIRST COAT OF PRIMER IS APPLIED, ON ALL NEW OR EXISTING ITEMS BEING REPAIRED, ALL JOINTS MUST BE AFTER THE FIRST COAT OF PRIMER IS APPLIED, ON ALL NEW OR EXISTING ITEMS BEING REPAIRED, ALL JOINTS MUST BE INSPECTED. ANY IRREGULARITIES, IMPERFECTIONS, OR VISIBLE JOINTS IN NEW AND EXISTING AND OR PLASTER MUST BE CORRECTED AND RE-PRIMED BEFORE APPLYING THE FINAL FINISHES. PROJECT SPECIFICATION - ELECTRICAL: 1. LIGHT FIXTURE: LIGHT FIXTURE: 1.1. CPX SERIES, CATALOG #2X4 40L 35K SSAIR APIR, MANUFACTURED BY LITHONIA LIGHTING OR APPROVED EQUAL CPX SERIES, CATALOG #2X4 40L 35K SSAIR APIR, MANUFACTURED BY LITHONIA LIGHTING OR APPROVED EQUAL 1.2. CPX SERIES, CATALOG #2X2 32L 35K SSAIR APIR, MANUFACTURED BY LITHONIA LIGHTING OR APPROVED EQUAL CPX SERIES, CATALOG #2X2 32L 35K SSAIR APIR, MANUFACTURED BY LITHONIA LIGHTING OR APPROVED EQUAL 1.3. VENTILATION LIGHT VENTILATION LIGHT 1.3.1. PRODUCT #FV-0511VFL1, MANUFACTURED BY PANASONIC OR APPROVED EQUAL PRODUCT #FV-0511VFL1, MANUFACTURED BY PANASONIC OR APPROVED EQUAL 1.3.1. VENTILATION LIGHT TO BE A DUAL LIGHT AND EXHAUST FAN FIXTURE VENTILATION LIGHT TO BE A DUAL LIGHT AND EXHAUST FAN FIXTURE 1.4. EXIT LIGHT EXIT LIGHT 1.4.1. LPX7 SERIES, IVORY COLOR, MANUFACTURED BY COOPER LIGHTING OR APPROVED EQUAL LPX7 SERIES, IVORY COLOR, MANUFACTURED BY COOPER LIGHTING OR APPROVED EQUAL 1.4.2. LPXC SERIES, IVORY COLOR, MANUFACTURED BY COOPER LIGHTING OR APPROVED EQUAL LPXC SERIES, IVORY COLOR, MANUFACTURED BY COOPER LIGHTING OR APPROVED EQUAL 1.4.1. NEW EXIT LIGHT FIXTURES SHALL BE EQUIPPED WITH DIRECTIONAL ARROWS AS SHOWN ON THE REFLECTED CEILING PLAN. NEW EXIT LIGHT FIXTURES SHALL BE EQUIPPED WITH DIRECTIONAL ARROWS AS SHOWN ON THE REFLECTED CEILING PLAN. SHADING IN THE SPECIFIED DIRECTIONS INDICATES THE ORIENTATION AND NUMBER OF ILLUMINATED FACES 1.4.2. NEW EXIT LIGHT FIXTURES SHALL BE DOUBLE SIDED AS NOTED IN THE REFLECTED CEILING PLAN NEW EXIT LIGHT FIXTURES SHALL BE DOUBLE SIDED AS NOTED IN THE REFLECTED CEILING PLAN 1.4.3. NEW EXIT LIGHT FIXTURES WILL HAVE EMERGENCY LIGHTS AS NOTED IN THE REFLECTED CEILING PLAN NEW EXIT LIGHT FIXTURES WILL HAVE EMERGENCY LIGHTS AS NOTED IN THE REFLECTED CEILING PLAN 2. LIGHT SWITCH: LIGHT SWITCH: 2.1. 20-AMP SINGLE-POLE TOGGLE LIGHT SWITCH, COMMERCIAL GRADE, MANUFACTURED BY EATON OR APPROVED EQUAL 20-AMP SINGLE-POLE TOGGLE LIGHT SWITCH, COMMERCIAL GRADE, MANUFACTURED BY EATON OR APPROVED EQUAL 2.1.1. SIZE: MID-SIZE SIZE: MID-SIZE 2.1.2. COLOR: IVORY COLOR: IVORY 3. RECEPTACLE: RECEPTACLE: 3.1. 20-AMP, COMMERCIAL GRADE, METALLIC AND APPROVED FOR USE WITH METAL CLAD CABLE 20-AMP, COMMERCIAL GRADE, METALLIC AND APPROVED FOR USE WITH METAL CLAD CABLE 3.1.1. SIZE: MID-SIZE SIZE: MID-SIZE 3.1.2. COLOR: IVORY COLOR: IVORY PROJECT SPECIFICATION - MECHANICAL: 4. SUPPLY DIFFUSER: SUPPLY DIFFUSER: 4.0.1. TMS SERIES, LAY-IN, MANUFACTURED BY TITUS OR APPROVED EQUAL. TMS SERIES, LAY-IN, MANUFACTURED BY TITUS OR APPROVED EQUAL. 4.0.2. FINISH: #26 WHITE FINISH: #26 WHITE 5. RETURN DIFFUSER: RETURN DIFFUSER: 5.0.1. PMR SERIES, LAY-IN, 2-WAY OPPOSITE, MANUFACTURED BY TITUS OR APPROVED EQUAL. PMR SERIES, LAY-IN, 2-WAY OPPOSITE, MANUFACTURED BY TITUS OR APPROVED EQUAL. 5.0.2. FINISH: #26 WHITE FINISH: #26 WHITE 6. EXHAUST FAN: EXHAUST FAN: 6.1. PANASONIC WHISPERFIT, PRODUCT NUMBER FV-0511VFL1, MANUFACTURED BY PANASONIC OR APPROVED EQUAL. PANASONIC WHISPERFIT, PRODUCT NUMBER FV-0511VFL1, MANUFACTURED BY PANASONIC OR APPROVED EQUAL. 6.1.1. CFM: 110 CFM: 110 7. HANGERS: HANGERS: 7.1. RECTANGULAR METAL DUCTWORK: RECTANGULAR METAL DUCTWORK: 7.1.1. METAL PLUMBING STRAPS (EVERY 5'-0") METAL PLUMBING STRAPS (EVERY 5'-0") 7.1.2. 3/4" WIDE, MINIMUM 3/4" WIDE, MINIMUM 7.1.3. 26 GAUGE, GALVANIZED 26 GAUGE, GALVANIZED 7.1.4. 1 1/2" #10 WOOD SCREWS 1 1/2" #10 WOOD SCREWS 7.2. FLEX DUCTWORK: FLEX DUCTWORK: 7.2.1. WEBBING STRAP (EVERY 4'-0") WEBBING STRAP (EVERY 4'-0") 7.2.2. 3" WIDE, MINIMUM 3" WIDE, MINIMUM 7.2.3. CAP NAILS CAP NAILS PROJECT SPECIFICATIONS - FINISHES: 1. PAINT PAINT 1.1. WALLS: WALLS: 1.1.1. MANUFACTURED BY PURE PERFORMANCE OR APPROVED EQUAL. MANUFACTURED BY PURE PERFORMANCE OR APPROVED EQUAL. 1.1.2. PRIMER: GRIPPER OR APPROVED EQUAL. PRIMER: GRIPPER OR APPROVED EQUAL. 1.1.2.1. GENERAL COLORING: GENERAL COLORING: 1.1.3. FINISH: EGGSHELL FINISH: EGGSHELL 1.1.4. COLOR: DOVER WHITE COLOR: DOVER WHITE 1.1.4.1. FRONT DESK COLORING: FRONT DESK COLORING: 1.1.5. FINISH: FINISH: 1.1.6. COLOR: COLOR: 1.2. DOOR FRAMES: DOOR FRAMES: 1.2.1. MANUFACTURED BY PURE PERFORMANCE OR APPROVED EQUAL. MANUFACTURED BY PURE PERFORMANCE OR APPROVED EQUAL. 1.2.2. PRIMER: GRIPPER OR APPROVED EQUAL PRIMER: GRIPPER OR APPROVED EQUAL 1.2.3. FINISH: SEMI-GLOSS FINISH: SEMI-GLOSS 1.2.4. COLOR: DOVER WHITE COLOR: DOVER WHITE 2. BASEBOARD BASEBOARD 2.1. SELECTION 1: SELECTION 1: 2.1.1. WOOD BASEBOARD, 4"x1/8" WOODEN WALL BASE, WOOD BASEBOARD, 4"x1/8" WOODEN WALL BASE, 2.1.2. COLOR: DOVER WHITE COLOR: DOVER WHITE 3. CEILINGS CEILINGS 3.1. ACOUSTICAL CEILING TILE (BB): ACOUSTICAL CEILING TILE (BB): 3.1.1. 2'x2', TEGULAR EDGE, MANUFACTURED BY ARMSTRONG OR APPROVED EQUAL. 2'x2', TEGULAR EDGE, MANUFACTURED BY ARMSTRONG OR APPROVED EQUAL. 3.1.2. 2'X4', TEGULAR EDGE, MANUFACTURED BY ARMSTRONG OR APPROVED EQUAL. 2'X4', TEGULAR EDGE, MANUFACTURED BY ARMSTRONG OR APPROVED EQUAL. 3.1.3. FINISH: FISSURED FINISH: FISSURED 3.1.4. COLOR: WHITE COLOR: WHITE 3.2. GYPSUM WALLBOARD GYPSUM WALLBOARD 3.2.1. MOISTURE/MOLD RESISTANT, PRODUCT NUMBER 011932, MANUFACTURED BY TOUGHROCK OR APPROVED EQUAL. MOISTURE/MOLD RESISTANT, PRODUCT NUMBER 011932, MANUFACTURED BY TOUGHROCK OR APPROVED EQUAL. 3.2.2. FINISH: PAINTED FINISH: PAINTED 3.2.3. COLOR: P1 COLOR: P1
AutoCAD SHX Text G-002
AutoCAD SHX Text
LIGHTING SCHEDULE
AutoCAD SHX Text
TAG
AutoCAD SHX Text
CATALOG NO.
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
VOLT
AutoCAD SHX Text
WATTS
AutoCAD SHX Text
COMMENTS
AutoCAD SHX Text L-1
AutoCAD SHX Text
LITHONIA, 2X4 40L 2X4 40L 35K SSAIR APIR
AutoCAD SHX Text 2'X4'
AutoCAD SHX Text 120-277
AutoCAD SHX Text 36.7
AutoCAD SHX Text L-2
AutoCAD SHX Text
LITHONIA, 2X2 32L 2X2 32L 35K SSAIR APIR
AutoCAD SHX Text 2'X2'
AutoCAD SHX Text 120-277
AutoCAD SHX Text 30.1
AutoCAD SHX Text L-3
AutoCAD SHX Text
PANASONIC, FV-0511VFL1
AutoCAD SHX Text 13"X13"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Dual light and exhaust fan
AutoCAD SHX Text L-4
AutoCAD SHX Text
LPX7WGS11
AutoCAD SHX Text 13"X7'-1/2"
AutoCAD SHX Text 120-277
AutoCAD SHX Text
AutoCAD SHX Text Assorted single/double sided as noted
AutoCAD SHX Text L-5
AutoCAD SHX Text
LPXC25R3
AutoCAD SHX Text 13"X7'-1/2"
AutoCAD SHX Text 120-277
AutoCAD SHX Text
AutoCAD SHX Text Exit and emergency light, both to be double sided
AutoCAD SHX Text
DOOR SCHEDULE
AutoCAD SHX Text
TAG
AutoCAD SHX Text
SWING
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
DOOR TYPE
AutoCAD SHX Text
FRAME TYPE
AutoCAD SHX Text
COMMENTS
AutoCAD SHX Text D-1
AutoCAD SHX Text
LH
AutoCAD SHX Text
ENTRANCE HARDWARE
AutoCAD SHX Text
BIRCH; VENT
AutoCAD SHX Text
CURRIES SERIES C
AutoCAD SHX Text Jamb detail, interior
AutoCAD SHX Text D-2
AutoCAD SHX Text
LH
AutoCAD SHX Text
ENTRANCE HARDWARE
AutoCAD SHX Text
BIRCH; VENT
AutoCAD SHX Text
CURRIES SERIES C
AutoCAD SHX Text Jamb detail, interior at existing wall
AutoCAD SHX Text D-3
AutoCAD SHX Text
LH
AutoCAD SHX Text
ENTRANCE HARDWARE
AutoCAD SHX Text
BIRCH; WINDOW
AutoCAD SHX Text
CURRIES SERIES C
AutoCAD SHX Text Jamb detail, interior
AutoCAD SHX Text D-4
AutoCAD SHX Text
LH
AutoCAD SHX Text
ENTRANCE HARDWARE
AutoCAD SHX Text
BIRCH; HOLLOW
AutoCAD SHX Text
CURRIES SERIES C
AutoCAD SHX Text Jamb detail, interior
AutoCAD SHX Text D-5
AutoCAD SHX Text
RH
AutoCAD SHX Text
ENTRANCE HARDWARE
AutoCAD SHX Text
BIRCH; HOLLOW
AutoCAD SHX Text
CURRIES SERIES C
AutoCAD SHX Text Jamb detail, interior
AutoCAD SHX Text D-6
AutoCAD SHX Text
RH
AutoCAD SHX Text
ENTRANCE HARDWARE
AutoCAD SHX Text
BIRCH; HOLLOW
AutoCAD SHX Text
CURRIES SERIES C
AutoCAD SHX Text Jamb detail, interior
AutoCAD SHX Text
PANEL SCHEDULE: EP1 (ANNEX)
AutoCAD SHX Text
AMP: 125 (24 SPACES)
AutoCAD SHX Text
VOLTAGE: 120240
AutoCAD SHX Text
PHASE: 1Φ
AutoCAD SHX Text
WIRE: 3
AutoCAD SHX Text
CIRCUIT NO.
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
CIRCUIT NO.
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN (2 POLE)
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN (2 POLE)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
UNKNOWN
AutoCAD SHX Text
AutoCAD SHX Text
TOGGLE SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
TOGGLE SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
TOGGLE SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
TOGGLE SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
TOGGLE SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
RECEPTACLE
AutoCAD SHX Text
AutoCAD SHX Text
RECEPTACLE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PANEL SCHEDULE: EP2 (EXISTING P&R SPACE)
AutoCAD SHX Text
AMP: 125 (22 SPACES)
AutoCAD SHX Text
VOLTAGE: 120240
AutoCAD SHX Text
PHASE: 1Φ
AutoCAD SHX Text
WIRE: 3
AutoCAD SHX Text
CIRCUIT NO.
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
CIRCUIT NO.
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
AutoCAD SHX Text
AC (2 POLE)
AutoCAD SHX Text
AutoCAD SHX Text
HEAT (2 POLE)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RECEPTACLE
AutoCAD SHX Text
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
AutoCAD SHX Text
RECEPTACLE
AutoCAD SHX Text
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
AutoCAD SHX Text
RECEPTACLE
AutoCAD SHX Text
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
AutoCAD SHX Text
WATER HEATER
AutoCAD SHX Text
AutoCAD SHX Text
TOGGLE SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
TOGGLE SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
TOGGLE SWITCH
AutoCAD SHX Text
AutoCAD SHX Text
RECEPTACLE
AutoCAD SHX Text
AutoCAD SHX Text
RECEPTACLE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DEPT. OF PUBLIC WORKS
AutoCAD SHX Text
PARKS AND RECREATION WASHINGTON SQUARE ADDITION GENERAL NOTES AND SCHEDULE
AutoCAD SHX Text 05/13/2026
AutoCAD SHX Text Initial Preliminary Design
AutoCAD SHX Text 4/2/26
AutoCAD SHX Text
AutoCAD SHX Text Revised Preliminary Design
AutoCAD SHX Text 4/23/26
AutoCAD SHX Text
AutoCAD SHX Text Revised Final Design
AutoCAD SHX Text 5/13/26
Feet 0 3 6
Y O
R K
C O
U N
T Y
SE
R
V
IC
E D
R
IV
E
PO
ST
O
FF
IC
E B
O X
Y O
R K
T O
W N
, V
IR
G
IN
IA
0-
(7
) 8
-3
FA
X : 8
-3
Feet 0 3 6
AutoCAD SHX Text
RESTROOM 55 SF
AutoCAD SHX Text
OFFICE 120 SF
AutoCAD SHX Text
OFFICE 110 SF
AutoCAD SHX Text
STORAGE ROOM 180 SF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RESTROOM 55 SF
AutoCAD SHX Text
BUILDING ADDITION 810 SF
AutoCAD SHX Text
REST- ROOM 25 SF
AutoCAD SHX Text
REST- ROOM 25 SF
AutoCAD SHX Text
OFFICE 50 SF
AutoCAD SHX Text
BATHROOM 90 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
RECEPTION DESK 80 SF
AutoCAD SHX Text
OFFICE 95 SF
AutoCAD SHX Text
CONFERENCE ROOM 200 SF
AutoCAD SHX Text
RECEPTION DESK 100 SF
AutoCAD SHX Text
OFFICE 100 SF
AutoCAD SHX Text
CONFERENCE ROOM 195 SF
AutoCAD SHX Text
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text Revisions/Comments/Notes
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text
PM
AutoCAD SHX Text GENERAL NOTES (THIS SHEET ONLY): 1. ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND APPLICABLE CODES AS CURRENTLY ENFORCED IN THE COUNTY OF YORK AND/OR WITHIN THE STATE OF VIRGINIA. 2. ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN THE PROJECT AREA. ALL BLACK/DARK LINE WORK THROUGHOUT THIS PLAN INDICATE ITEMS TO BE DEMOLISHED OR ADDED FOR CONSTRUCTION WITHIN THE PROJECT AREA. 3. ITEMS IDENTIFIED AS "OPTIONAL" INDICATE WORK THAT IS SUBJECT TO ACCEPTANCE ITEMS IDENTIFIED AS "OPTIONAL" INDICATE WORK THAT IS SUBJECT TO ACCEPTANCE UNDER ADDITIVE BID ITEM #1 (GENERAL DEMOLITION). REFER TO THE CONTRACT DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 4. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL WALLS AND RELATED MATERIAL CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL WALLS AND RELATED MATERIAL SHOWN AS DEMOLISHED. ALL MATERIALS AND EQUIPMENT TO BE REMOVED BECOMES PROPERTY OF THE CONTRACTOR UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PROPERLY DISPOSE OF ALL SUCH MATERIAL AND EQUIPMENT OFF SITE. KEY NOTES (THIS SHEET ONLY): 1. EXISTING DOOR AND FRAME TO BE REMOVED. THIS IS AN OPTIONAL WORK ITEM; SEE EXISTING DOOR AND FRAME TO BE REMOVED. THIS IS AN OPTIONAL WORK ITEM; SEE GENERAL NOTE 3 FOR MORE DETAILS. 2. CONTRACTOR TO REMOVE +/- 5 LF OF EXISTING TILE WALL AND BASEBOARD. THIS IS CONTRACTOR TO REMOVE +/- 5 LF OF EXISTING TILE WALL AND BASEBOARD. THIS IS THIS IS AN OPTIONAL WORK ITEM; SEE GENERAL NOTE 3 FOR MORE DETAILS. 3. CONTRACTOR TO REMOVE +/- 36 LF OF EXISTING STANDARD WALL AND BASEBOARD. CONTRACTOR TO REMOVE +/- 36 LF OF EXISTING STANDARD WALL AND BASEBOARD. CONTRACTOR TO REMOVE WALL TO BACK TO CLOSEST STUD. WALL REMOVAL NOT TO DISRUPT INTEGRITY OF EXISTING DOOR FRAMES. THIS IS AN OPTIONAL WORK ITEM; SEE THIS IS AN OPTIONAL WORK ITEM; SEE GENERAL NOTE 3 FOR MORE DETAILS.
AutoCAD SHX Text
AutoCAD SHX Text 1"=3'
AutoCAD SHX Text A-101
AutoCAD SHX Text
DEPT. OF PUBLIC WORKS
AutoCAD SHX Text
FLOOR PLAN DEMO AREA A
AutoCAD SHX Text
PARKS AND RECREATION WASHINGTON SQUARE ADDITION FLOOR PLAN DEMO
AutoCAD SHX Text
FLOOR PLAN DEMO AREA B
AutoCAD SHX Text
MATCHLINE - SEE AREA B
AutoCAD SHX Text
MATCHLINE - SEE AREA A
AutoCAD SHX Text Initial Preliminary Design
AutoCAD SHX Text 4/2/26
AutoCAD SHX Text
AutoCAD SHX Text Revised Preliminary Design
AutoCAD SHX Text 4/23/26
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL BOX
AutoCAD SHX Text Closet 5 SF
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA A
AutoCAD SHX Text 05/13/2026
AutoCAD SHX Text Revised Final Design
AutoCAD SHX Text 5/13/26
0 3 6
Y O
R K
C O
U N
T Y
SE
R
V
IC
E D
R
IV
E
PO
ST
O
FF
IC
E B
O X
Y O
R K
T O
W N
, V
IR
G
IN
IA
0-
(7
) 8
-3
FA
X : 8
-3
Feet 0 3 6
AutoCAD SHX Text
RESTROOM 55 SF
AutoCAD SHX Text
OFFICE 120 SF
AutoCAD SHX Text
OFFICE 110 SF
AutoCAD SHX Text
STORAGE ROOM 180 SF
AutoCAD SHX Text
LARGE STORAGE ROOM 230 SF
AutoCAD SHX Text
CONFERENCE ROOM 340 SF
AutoCAD SHX Text
ELECTRICAL ROOM 70 SF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D-1
AutoCAD SHX Text D-2
AutoCAD SHX Text D-3
AutoCAD SHX Text D-4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RESTROOM 25 SF
AutoCAD SHX Text
REST- ROOM 25 SF
AutoCAD SHX Text
REST- ROOM 25 SF
AutoCAD SHX Text
OFFICE 50 SF
AutoCAD SHX Text
BATHROOM 90 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
RECEPTION DESK 80 SF
AutoCAD SHX Text
OFFICE 95 SF
AutoCAD SHX Text
CONFERENCE ROOM 200 SF
AutoCAD SHX Text
RECEPTION DESK 100 SF
AutoCAD SHX Text
OFFICE 100 SF
AutoCAD SHX Text
OFFICE 90 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
AutoCAD SHX Text D-5
AutoCAD SHX Text D-6
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text Revisions/Comments/Notes
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text
PM
AutoCAD SHX Text GENERAL NOTES (THIS SHEET ONLY): 1. ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND APPLICABLE CODES AS CURRENTLY ENFORCED IN THE COUNTY OF YORK AND/OR WITHIN THE STATE OF VIRGINIA. 2. ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN THE PROJECT AREA. ALL BLACK/DARK LINE WORK THROUGHOUT THIS PLAN INDICATE ITEMS TO BE DEMOLISHED OR ADDED FOR CONSTRUCTION WITHIN THE PROJECT AREA. 3. ITEMS IDENTIFIED AS "OPTIONAL" INDICATE WORK THAT IS SUBJECT TO ACCEPTANCE ITEMS IDENTIFIED AS "OPTIONAL" INDICATE WORK THAT IS SUBJECT TO ACCEPTANCE UNDER ADDITIVE BID ITEM #2 (CONSTRUCTION FRAMING). REFER TO THE CONTRACT DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 4. CONTRACTOR TO TAKE CARE AS TO NOT DISRUPT SERVICES IN OTHER AREAS/PARTS OF CONTRACTOR TO TAKE CARE AS TO NOT DISRUPT SERVICES IN OTHER AREAS/PARTS OF AREAS/PARTS OF THE BUILDING OR THE SURROUNDING OFFICE SPACES. PLEASE NOTIFY THE OWNER PRIOR TO COMMENCING SUCH WORK AS THE REMOVAL, RELOCATION, AND/OR ADDITION OF A CIRCUIT, UTILITY, OR ITEM MAY DISRUPT POWER, LIGHTING, COMMUNICATION/DATA, FIRE SYSTEMS, OR SOME OTHER SERVICE IN OTHER OCCUPIED AREAS THROUGHOUT THE BUILDING. 5. CONTRACTOR TO ENSURE THAT ALL ENTRANCES TO THE PROJECT AREA ARE MADE CONTRACTOR TO ENSURE THAT ALL ENTRANCES TO THE PROJECT AREA ARE MADE ALL ENTRANCES TO THE PROJECT AREA ARE MADE ACCESSIBLE AND KEPT CLEAR OF DEBRIS, EQUIPMENT, AND MATERIAL THROUGHOUT THE DURATION OF THE PROJECT. IF CLOSURE OF ENTRANCE/HALLWAY IS REQUIRED, INFORM THE OWNER IN ADVANCE TO ENSURE THAT SURROUNDING OFFICES/EMPLOYEES ARE NOT NEGATIVELY IMPACTED. 6. CONTRACTOR IS RESPONSIBLE FOR THE PURCHASE AND INSTALLATION OF ALL ITEMS CONTRACTOR IS RESPONSIBLE FOR THE PURCHASE AND INSTALLATION OF ALL ITEMS LISTED IN THE DRAWING PACKAGE UNLESS CLEARLY MARKED AS "OWNER PROVIDED, OWNER, OR THIRD PARTY INSTALLED." IN SOME CASES THE CONTRACTOR IS REQUIRED TO INSTALL OWNER PROVIDED EQUIPMENT AND SYSTEMS. 7. CONTRACTOR TO ENSURE THAT ALL NEW DOORS MUST COMPLY WITH THE ADA DOOR CONTRACTOR TO ENSURE THAT ALL NEW DOORS MUST COMPLY WITH THE ADA DOOR APPROACH AND CLEARANCE GUIDELINES AS INDICATED ON SHEET A-109. 8. WHERE EQUIPMENT AND CONDUIT HAS BEEN REMOVED FROM EXISTING SURFACES, REPAIR WHERE EQUIPMENT AND CONDUIT HAS BEEN REMOVED FROM EXISTING SURFACES, REPAIR HOLES LEFT BY MOUNTING HARDWARE. PATCH, PAINT, AND FINISH WALLS, FLOORS, AND CEILING TO MATCH EXISTING OR NEW ADJACENT SURFACES PER THE "WALL FINISHING GENERAL NOTES" ON SHEET G-002. 9. SEE "PROJECT SPECIFICATIONS" ON SHEET G-002 FOR DETAILED PRODUCT INFORMATION SEE "PROJECT SPECIFICATIONS" ON SHEET G-002 FOR DETAILED PRODUCT INFORMATION FOR ALL NEW ITEMS. KEY NOTES (THIS SHEET ONLY): 1. CONTRACTOR TO CONSTRUCT +/- 100 LF OF METAL WALL FRAME . SEE "WALL DETAIL CONTRACTOR TO CONSTRUCT +/- 100 LF OF METAL WALL FRAME . SEE "WALL DETAIL (TYP)" ON SHEET A-109 FOR ADDITIONAL INFORMATION. 2. CONTRACTOR TO PATCH, DRYWALL, AND FINISH NEW WALL FRAMES. SEE "WALL FINISHING CONTRACTOR TO PATCH, DRYWALL, AND FINISH NEW WALL FRAMES. SEE "WALL FINISHING GENERAL NOTES" ON SHEET G-002 FOR ADDITIONAL INFORMATION. 3. CONTRACTOR TO INSTALL NEW DOORS AND PRIME/PAINT NEW DOOR FRAMES. SEE "DOOR CONTRACTOR TO INSTALL NEW DOORS AND PRIME/PAINT NEW DOOR FRAMES. SEE "DOOR SCHEDULE - NEW" ON SHEET G-002 FOR ADDITIONAL INFORMATION. 4. CONTRACTOR TO PAINT EXISTING AND NEW WALLS. SEE SHEET G-002 FOR ADDITIONAL CONTRACTOR TO PAINT EXISTING AND NEW WALLS. SEE SHEET G-002 FOR ADDITIONAL INFORMATION. 5. CONTRACTOR TO CONSTRUCT +/- 20 LF OF METAL WALL FRAME . SEE "WALL DETAIL CONTRACTOR TO CONSTRUCT +/- 20 LF OF METAL WALL FRAME . SEE "WALL DETAIL (TYP)" ON SHEET A-109 FOR ADDITIONAL INFORMATION. THIS IS AN OPTIONAL WORK THIS IS AN OPTIONAL WORK ITEM; SEE GENERAL NOTE 3 FOR MORE DETAILS.
AutoCAD SHX Text
AutoCAD SHX Text 1"=3'
AutoCAD SHX Text A-102
AutoCAD SHX Text
DEPT. OF PUBLIC WORKS
AutoCAD SHX Text
PARKS AND RECREATION WASHINGTON SQUARE ADDITION FLOOR PLAN CONSTRUCTION
AutoCAD SHX Text
FLOOR PLAN CONST. AREA A
AutoCAD SHX Text
FLOOR PLAN CONST. AREA B
AutoCAD SHX Text
MATCHLINE - SEE AREA B
AutoCAD SHX Text
MATCHLINE - SEE AREA A
AutoCAD SHX Text Initial Preliminary Design
AutoCAD SHX Text 4/2/26
AutoCAD SHX Text
AutoCAD SHX Text Revised Preliminary Design
AutoCAD SHX Text 4/23/26
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL BOX
AutoCAD SHX Text Closet 5 SF
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA A
AutoCAD SHX Text 05/13/2026
AutoCAD SHX Text Revised Final Design
AutoCAD SHX Text 5/13/26
Feet 0 3 6
Y O
R K
C O
U N
T Y
SE
R
V
IC
E D
R
IV
E
PO
ST
O
FF
IC
E B
O X
Y O
R K
T O
W N
, V
IR
G
IN
IA
0-
(7
) 8
-3
FA
X : 8
-3
Feet 0 3 6
AutoCAD SHX Text
RESTROOM 55 SF
AutoCAD SHX Text
OFFICE 120 SF
AutoCAD SHX Text
OFFICE 110 SF
AutoCAD SHX Text
STORAGE ROOM 180 SF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REST- ROOM 25 SF
AutoCAD SHX Text
REST- ROOM 25 SF
AutoCAD SHX Text
OFFICE 50 SF
AutoCAD SHX Text
BATHROOM 90 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
RECEPTION DESK 80 SF
AutoCAD SHX Text
OFFICE 95 SF
AutoCAD SHX Text
CONFERENCE ROOM 200 SF
AutoCAD SHX Text
RECEPTION DESK 100 SF
AutoCAD SHX Text
OFFICE 100 SF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text Revisions/Comments/Notes
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text 1"=3'
AutoCAD SHX Text
PM
AutoCAD SHX Text GENERAL NOTES (THIS SHEET ONLY): 1. ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND APPLICABLE CODES AS CURRENTLY ENFORCED IN THE COUNTY OF YORK AND/OR WITHIN THE STATE OF VIRGINIA. 2. ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN THE PROJECT AREA. ALL BLACK/DARK LINE WORK THROUGHOUT THIS PLAN INDICATE ITEMS TO BE DEMOLISHED OR ADDED FOR CONSTRUCTION WITHIN THE PROJECT AREA. 3. ITEMS IDENTIFIED AS "OPTIONAL" INDICATE WORK THAT IS SUBJECT TO ACCEPTANCE ITEMS IDENTIFIED AS "OPTIONAL" INDICATE WORK THAT IS SUBJECT TO ACCEPTANCE UNDER ADDITIVE BID ITEM #1 (GENERAL DEMOLITION). REFER TO THE CONTRACT DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 4. CONTRACTOR TO TAKE CARE AS TO NOT DISRUPT SERVICES IN OTHER AREAS/PARTS OF CONTRACTOR TO TAKE CARE AS TO NOT DISRUPT SERVICES IN OTHER AREAS/PARTS OF AREAS/PARTS OF THE BUILDING OR THE SURROUNDING OFFICE SPACES. PLEASE NOTIFY THE OWNER PRIOR TO COMMENCING SUCH WORK AS THE REMOVAL, RELOCATION, AND/OR ADDITION OF A CIRCUIT, UTILITY, OR ITEM MAY DISRUPT POWER, LIGHTING, COMMUNICATION/DATA, FIRE SYSTEMS, OR SOME OTHER SERVICE IN OTHER OCCUPIED AREAS THROUGHOUT THE BUILDING. 5. CONTRACTOR TO ENSURE THAT ALL ENTRANCES TO THE PROJECT AREA ARE MADE CONTRACTOR TO ENSURE THAT ALL ENTRANCES TO THE PROJECT AREA ARE MADE ALL ENTRANCES TO THE PROJECT AREA ARE MADE ACCESSIBLE AND KEPT CLEAR OF DEBRIS, EQUIPMENT, AND MATERIAL THROUGHOUT THE DURATION OF THE PROJECT. IF CLOSURE OF ENTRANCE/HALLWAY IS REQUIRED, INFORM THE OWNER IN ADVANCE TO ENSURE THAT SURROUNDING OFFICES/EMPLOYEES ARE NOT NEGATIVELY IMPACTED. 6. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL RELATED MATERIAL SHOWN AS CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL RELATED MATERIAL SHOWN AS DEMOLISHED. ALL MATERIALS AND EQUIPMENT TO BE REMOVED BECOMES PROPERTY OF THE CONTRACTOR UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PROPERLY DISPOSE OF ALL SUCH MATERIAL AND EQUIPMENT OFF SITE. KEY NOTES (THIS SHEET ONLY): 1. CONTRACTOR TO DEMOLISH +/- 680 SF OF EXISTING 2'X4' HANGING CEILING, CONTRACTOR TO DEMOLISH +/- 680 SF OF EXISTING 2'X4' HANGING CEILING, SUPPORTS, AND INSULATION. IF POSSIBLE, DEMOLISHED CEILING TILES TO BE RE-USED IN CONSTRUCTION. THIS IS AN OPTIONAL WORK ITEM; SEE GENERAL NOTE 3 FOR MORE DETAILS. 2. CONTRACTOR TO DEMOLISH +/- 4 SF OF EXISTING 2'X2' HANGING CEILING TILES, CONTRACTOR TO DEMOLISH +/- 4 SF OF EXISTING 2'X2' HANGING CEILING TILES, SUPPORTS, AND INSULATION. IF POSSIBLE, DEMOLISHED CEILING TILES TO BE RE-USED IN CONSTRUCTION. THIS IS AN OPTIONAL WORK ITEM; SEE GENERAL NOTE 3 FOR MORE DETAILS. 3. CONTRACTOR TO REMOVE EXISTING LIGHT FIXTURES. ALL ASSOCIATED WIRING AND BOXES CONTRACTOR TO REMOVE EXISTING LIGHT FIXTURES. ALL ASSOCIATED WIRING AND BOXES TO BE TERMINATED AND REMOVED ACCORDINGLY. IF POSSIBLE, REMOVED LIGHT FIXTURES TO BE RE-USED IN CONSTRUCTION. THIS IS AN OPTIONAL WORK ITEM; SEE GENERAL NOTE 3 FOR MORE DETAILS. 4. EXISTING TOGGLE LIGHT SWITCH TO BE REMOVED. ALL ASSOCIATED WIRING AND BOXES EXISTING TOGGLE LIGHT SWITCH TO BE REMOVED. ALL ASSOCIATED WIRING AND BOXES TO BE TERMINATED AND REMOVED ACCORDINGLY. THIS IS AN OPTIONAL WORK ITEM; SEE GENERAL NOTE 3 FOR MORE DETAILS.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
AutoCAD SHX Text A-103
AutoCAD SHX Text
DEPT. OF PUBLIC WORKS
AutoCAD SHX Text
PARKS AND RECREATION WASHINGTON SQUARE ADDITION REFLECTECD CEILING PLAN DEMO
AutoCAD SHX Text
CEILING PLAN DEMO AREA A
AutoCAD SHX Text
CEILING PLAN DEMO AREA B
AutoCAD SHX Text
MATCHLINE - SEE AREA B
AutoCAD SHX Text
MATCHLINE - SEE AREA A
AutoCAD SHX Text Initial Preliminary Design
AutoCAD SHX Text 4/2/26
AutoCAD SHX Text
AutoCAD SHX Text Revised Preliminary Design
AutoCAD SHX Text 4/23/26
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL BOX
AutoCAD SHX Text Closet 5 SF
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA A
AutoCAD SHX Text 05/13/2026
AutoCAD SHX Text Revised Final Design
AutoCAD SHX Text 5/13/26
TET
T
T
T
OS
OS
OS
OS
T
T
T
Feet 0 3 6
Y O
R K
C O
U N
T Y
SE
R
V
IC
E D
R
IV
E
PO
ST
O
FF
IC
E B
O X
Y O
R K
T O
W N
, V
IR
G
IN
IA
0-
(7
) 8
-3
FA
X : 8
-3
Feet 0 3 6
AutoCAD SHX Text
RESTROOM 55 SF
AutoCAD SHX Text
OFFICE 120 SF
AutoCAD SHX Text
OFFICE 110 SF
AutoCAD SHX Text
STORAGE ROOM 180 SF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text L-1
AutoCAD SHX Text L-1
AutoCAD SHX Text L-1
AutoCAD SHX Text L-1
AutoCAD SHX Text L-1
AutoCAD SHX Text L-1
AutoCAD SHX Text L-1
AutoCAD SHX Text L-1
AutoCAD SHX Text L-2
AutoCAD SHX Text L-2
AutoCAD SHX Text L-1
AutoCAD SHX Text L-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EP1-13
AutoCAD SHX Text
EP1-15
AutoCAD SHX Text
EP1-17
AutoCAD SHX Text
EP1-16
AutoCAD SHX Text
EP1-14
AutoCAD SHX Text
LARGE STORAGE ROOM 230 SF
AutoCAD SHX Text
CONFERENCE ROOM 340 SF
AutoCAD SHX Text
ELECTRICAL ROOM 70 SF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text L-4
AutoCAD SHX Text L-5
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REST- ROOM 25 SF
AutoCAD SHX Text
REST- ROOM 25 SF
AutoCAD SHX Text
OFFICE 50 SF
AutoCAD SHX Text
BATHROOM 90 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
RECEPTION DESK 80 SF
AutoCAD SHX Text
OFFICE 95 SF
AutoCAD SHX Text
CONFERENCE ROOM 200 SF
AutoCAD SHX Text
RECEPTION DESK 100 SF
AutoCAD SHX Text
OFFICE 100 SF
AutoCAD SHX Text L-2
AutoCAD SHX Text L-2
AutoCAD SHX Text L-2
AutoCAD SHX Text L-2
AutoCAD SHX Text L-2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE 90 SF
AutoCAD SHX Text
OFFICE 70 SF
AutoCAD SHX Text
EP2-13
AutoCAD SHX Text
AutoCAD SHX Text
EP2-14
AutoCAD SHX Text
EP2-15
AutoCAD SHX Text
AutoCAD SHX Text L-4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text Revisions/Comments/Notes
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text
PM
AutoCAD SHX Text 1"=3'
AutoCAD SHX Text
AutoCAD SHX Text A-104
AutoCAD SHX Text GENERAL NOTES (THIS SHEET ONLY): 1. ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND ALL MATERIALS AND WORK SHALL BE IN ACCORDANCE WITH INDUSTRY STANDARDS AND APPLICABLE CODES AS CURRENTLY ENFORCED IN THE COUNTY OF YORK AND/OR WITHIN THE STATE OF VIRGINIA. 2. ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN ALL GRAY/LIGHT LINE WORK THROUGHOUT THIS PLAN INDICATE EXISTING ITEMS FOUND IN THE PROJECT AREA. ALL BLACK/DARK LINE WORK THROUGHOUT THIS PLAN INDICATE ITEMS TO BE DEMOLISHED OR ADDED FOR CONSTRUCTION WITHIN THE PROJECT AREA. 3. ITEMS IDENTIFIED AS "OPTIONAL" INDICATE WORK THAT IS SUBJECT TO ACCEPTANCE ITEMS IDENTIFIED AS "OPTIONAL" INDICATE WORK THAT IS SUBJECT TO ACCEPTANCE UNDER ADDITIVE BID ITEM #2 (CONSTRUCTION FRAMING). REFER TO THE CONTRACT DOCUMENTS FOR ADDITIONAL REQUIREMENTS. 4. CONTRACTOR TO TAKE CARE AS TO NOT DISRUPT SERVICES IN OTHER AREAS/PARTS OF CONTRACTOR TO TAKE CARE AS TO NOT DISRUPT SERVICES IN OTHER AREAS/PARTS OF AREAS/PARTS OF THE BUILDING OR THE SURROUNDING OFFICE SPACES. PLEASE NOTIFY THE OWNER PRIOR TO COMMENCING SUCH WORK AS THE REMOVAL, RELOCATION, AND/OR ADDITION OF A CIRCUIT, UTILITY, OR ITEM MAY DISRUPT POWER, LIGHTING, COMMUNICATION/DATA, FIRE SYSTEMS, OR SOME OTHER SERVICE IN OTHER OCCUPIED AREAS THROUGHOUT THE BUILDING. 5. CONTRACTOR TO ENSURE THAT ALL ENTRANCES TO THE PROJECT AREA ARE MADE CONTRACTOR TO ENSURE THAT ALL ENTRANCES TO THE PROJECT AREA ARE MADE ALL ENTRANCES TO THE PROJECT AREA ARE MADE ACCESSIBLE AND KEPT CLEAR OF DEBRIS, EQUIPMENT, AND MATERIAL THROUGHOUT THE DURATION OF THE PROJECT. IF CLOSURE OF ENTRANCE/HALLWAY IS REQUIRED, INFORM THE OWNER IN ADVANCE TO ENSURE THAT SURROUNDING OFFICES/EMPLOYEES ARE NOT NEGATIVELY IMPACTED. 6. CONTRACTOR IS RESPONSIBLE FOR THE PURCHASE AND INSTALLATION OF ALL ITEMS CONTRACTOR IS RESPONSIBLE FOR THE PURCHASE AND INSTALLATION OF ALL ITEMS LISTED IN THE DRAWING PACKAGE UNLESS CLEARLY MARKED AS "OWNER PROVIDED, OWNER, OR THIRD PARTY INSTALLED." IN SOME CASES THE CONTRACTOR IS REQUIRED TO INSTALL OWNER PROVIDED EQUIPMENT AND SYSTEMS. 7. ALL WIRING SHALL BE MC (METAL CLAD) CABLE WITH ALL METALLIC BOXES APPROVED ALL WIRING SHALL BE MC (METAL CLAD) CABLE WITH ALL METALLIC BOXES APPROVED FOR USE WITH MC CABLE. ALL NEW WIRING TO BE RUN FROM EXISTING POWER PANEL "EP1". IF SPECIAL WIRE IS CALLED FOR IN THE MANUFACTURERS INSTALLATION INSTRUCTIONS, THAT WIRE SHALL BE USED INSTEAD. 8. ALL NEW LIGHT SWITCHES ARE TO BE TOGGLE LIGHT SWITCHES. ALL NEW LIGHT SWITCH ALL NEW LIGHT SWITCHES ARE TO BE TOGGLE LIGHT SWITCHES. ALL NEW LIGHT SWITCH CONNECTIONS TO BE WRAPPED AROUND THE SCREW PER THE MANUFACTURERS SPECIFICATIONS. NO STAB-IN TYPE CONNECTIONS. 9. ALL NEW LIGHT FIXTURES TO BE INSTALLED SO THAT THEY ARE IN COMPLIANCE WITH ALL NEW LIGHT FIXTURES TO BE INSTALLED SO THAT THEY ARE IN COMPLIANCE WITH THE MANUFACTURERS SPECIFICATIONS AND THE LIGHTING SCHEDULE. LIGHT FIXTURES SHALL BE SUPPORTED AND SUSPENDED BY HANGERS/ANCHORS TO THE FLOOR SLAB ABOVE. 10. CONTRACTOR TO REPLACE EXISTING CEILING TILES THAT ARE DAMAGED OR CONTRACTOR TO REPLACE EXISTING CEILING TILES THAT ARE DAMAGED OR PERMANENTLY REMOVED DURING DEMOLITION. CONTRACTOR SHALL REPLACE WITH NEW CEILING TILES OF THE SAME TYPE, COLOR, AND SIZE TO MATCH THE EXISTING FINISH. ALL REPLACEMENTS MUST BE SECURELY INSTALLED TO MAINTAIN CONSISTENCY AND INTEGRITY OF THE EXISTING CEILING. 11. SEE SHEET G-002 FOR ELECTRICAL PANEL SCHEDULES. SEE SHEET G-002 FOR ELECTRICAL PANEL SCHEDULES. 12. SEE SHEET G-002 FOR LIGHTING SCHEDULE. SEE SHEET G-002 FOR LIGHTING SCHEDULE. 13. SEE SHEET G-002 FOR DETAILED PRODUCT INFORMATION FOR ALL ITEMS, INCLUDING SEE SHEET G-002 FOR DETAILED PRODUCT INFORMATION FOR ALL ITEMS, INCLUDING ROOM FINISHES AND CEILING MATERIAL.. KEY NOTES (THIS SHEET ONLY): 1. CONTRACTOR TO INSTALL +/- 130 SF OF 2'x4' TILE SUSPENDED CEILING. NEW HANGING CONTRACTOR TO INSTALL +/- 130 SF OF 2'x4' TILE SUSPENDED CEILING. NEW HANGING 130 SF OF 2'x4' TILE SUSPENDED CEILING. NEW HANGING SF OF 2'x4' TILE SUSPENDED CEILING. NEW HANGING 2'x4' TILE SUSPENDED CEILING. NEW HANGING CEILING TO BE INSTALLED TO THE SAME HEIGHT AS THE SURROUNDING EXISTING HANGING CEILING AND THE GRID CHANNEL CONNECTED DIRECTLY TO THE NEW AND/OR EXISTING WALLS. 2. CONTRACTOR TO INSTALL +/- 234 SF OF 2'x2' TILE SUSPENDED CEILING. NEW HANGING CONTRACTOR TO INSTALL +/- 234 SF OF 2'x2' TILE SUSPENDED CEILING. NEW HANGING CEILING TO BE INSTALLED TO THE SAME HEIGHT AS THE SURROUNDING EXISTING HANGING CEILING AND THE GRID CHANNEL CONNECTED DIRECTLY TO THE NEW AND/OR EXISTING WALLS. 3. CONTRACTOR TO INSTALL NEW LIGHT FIXTURE. CONTRACTOR TO RUN NEW WIRING PER CONTRACTOR TO INSTALL NEW LIGHT FIXTURE. CONTRACTOR TO RUN NEW WIRING PER HOMERUN DIAGRAM AND PANEL SCHEDULE. SEE SHEET G-002 FOR FIXTURE DETAILS 4. CONTRACTOR TO RE-USE EXISTING LIGHT FIXTURES FOR INSTALLATION. CONTRACTOR TO CONTRACTOR TO RE-USE EXISTING LIGHT FIXTURES FOR INSTALLATION. CONTRACTOR TO RUN NEW WIRING PER HOMERUN DIAGRAM AND PANEL SCHEDULE. SEE SHEET G-002 FOR FIXTURE DETAILS 5. CONTRACTOR TO INSTALL NEW EXIT LIGHT FIXTURE. EXIT LIGHT TO BE CEILING MOUNTED. CONTRACTOR TO INSTALL NEW EXIT LIGHT FIXTURE. EXIT LIGHT TO BE CEILING MOUNTED. SEE SHEET G-002 FOR FIXTURE DETAILS. SHEET G-002 FOR FIXTURE DETAILS. 6. CONTRACTOR TO INSTALL NEW DOUBLE-SIDED COMBINATION EXIT AND EMERGENCY LIGHT CONTRACTOR TO INSTALL NEW DOUBLE-SIDED COMBINATION EXIT AND EMERGENCY LIGHT FIXTURE. EMERGENCY EXIT LIGHT TO BE CEILING MOUNTED. SEE SHEET G-002 FOR SHEET G-002 FOR FIXTURE DETAILS. 7. CONTRACTOR TO INSTALL NEW TOGGLE LIGHT SWITCH 4' ABOVE FINISHED FLOOR. CONTRACTOR TO INSTALL NEW TOGGLE LIGHT SWITCH 4' ABOVE FINISHED FLOOR. CONTRACTOR TO RUN NEW WIRING PER HOME RUN DESIGNATION. THIS IS AN OPTIONAL WORK ITEM; SEE GENERAL NOTE 3 FOR MORE DETAILS. 8. CONTRACTOR TO INSTALL OCCUPANCY SENSOR. OCCUPANCY SENSOR TO BE CEILING CONTRACTOR TO INSTALL OCCUPANCY SENSOR. OCCUPANCY SENSOR TO BE CEILING MOUNTED. SEE SHEET G-002 FOR FIXTURE DETAILS. 9. CONTRACTOR TO CONNECT NEW SUSPENDED TILE CEILING TO EXISTING CEILING CONTRACTOR TO CONNECT NEW SUSPENDED TILE CEILING TO EXISTING CEILING
AutoCAD SHX Text
DEPT. OF PUBLIC WORKS
AutoCAD SHX Text
CEILING PLAN CONST. AREA A
AutoCAD SHX Text
CEILING PLAN CONST. AREA B
AutoCAD SHX Text PARKS AND RECREATION WASHINGTON SQUARE ADDITION REFLECTED CEILING PLAN CONSTRUCTION
AutoCAD SHX Text
MATCHLINE - SEE AREA B
AutoCAD SHX Text
MATCHLINE - SEE AREA A
AutoCAD SHX Text Initial Preliminary Design
AutoCAD SHX Text 4/2/26
AutoCAD SHX Text
AutoCAD SHX Text Revised Preliminary Design
AutoCAD SHX Text 4/23/26
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL BOX
AutoCAD SHX Text Closet 5 SF
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA B
AutoCAD SHX Text
AREA A
AutoCAD SHX Text 05/13/2026
AutoCAD SHX Text Revised Final Design
AutoCAD SHX Text 5/13/26
" M
IN
" M
IN
MIN
18"60
" M
IN
36" MIN
" M
IN
MIN
22"
42" MIN
MIN
24"48
" M
IN
MIN
24"42
" M
IN
" M
IN12" MIN *
12" MIN *
FRONT APPROACH, PULL SIDE FRONT APPROACH, PUSH SIDE
*IF BOTH CLOSER AND LATCH ARE PROVIDED
HINGE APPROACH, PULL SIDE HINGE APPROACH, PULL SIDE
HINGE APPROACH, PUSH SIDE
*IF BOTH CLOSER AND LATCH ARE PROVIDED
**48" MIN IF BOTH CLOSER AND LATCH
PROVIDED
LATCH APPROACH, PULL SIDE
*54" MIN IF CLOSER PROVIDED
LATCH APPROACH, PUSH SIDE
*48" MIN IF CLOSER PROVIDED
Y O
R K
C O
U N
T Y
SE
R
V
IC
E D
R
IV
E
PO
ST
O
FF
IC
E B
O X
Y O
R K
T O
W N
, V
IR
G
IN
IA
0-
(7
) 8
-3
FA
X : 8
-3
AutoCAD SHX Text 2'
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 1'
AutoCAD SHX Text 1'-3"
AutoCAD SHX Text
SEE DOOR SCHEDULE
AutoCAD SHX Text
SEE DOOR SCHEDULE
AutoCAD SHX Text 4'-9"
AutoCAD SHX Text
SEE DOOR SCHEDULE
AutoCAD SHX Text
SEE DOOR SCHEDULE
AutoCAD SHX Text
SEE DOOR SCHEDULE
AutoCAD SHX Text
SEE DOOR SCHEDULE
AutoCAD SHX Text 1'-8"
AutoCAD SHX Text 5'-2"
AutoCAD SHX Text 8"
AutoCAD SHX Text 8"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
PM
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text Revisions/Comments/Notes
AutoCAD SHX Text Date
AutoCAD SHX Text No.
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
AutoCAD SHX Text A-105
AutoCAD SHX Text
JAMB DETAIL - INTERIOR (TYP.) SCALE: N.T.S.
AutoCAD SHX Text
JOINT SEALANT (BOTH SIDES)
AutoCAD SHX Text
SCHEDULED DOOR FRAME
AutoCAD SHX Text
GYPSUM WALL BOARD (TYP.)
AutoCAD SHX Text
METAL STUD FRAMING
AutoCAD SHX Text 2"
AutoCAD SHX Text 5/8"
AutoCAD SHX Text
THROAT
AutoCAD SHX Text
JOINT SEALANT (BOTH SIDES)
AutoCAD SHX Text
GYPSUM WALL BOARD (TYP.)
AutoCAD SHX Text 2"
AutoCAD SHX Text 5/8"
AutoCAD SHX Text
THROAT
AutoCAD SHX Text
EXIST. GYPSUM WALL BOARD (TYP.)
AutoCAD SHX Text
EXIST. WOOD/METAL FRAMING
AutoCAD SHX Text
SCHEDULED DOOR TYPE
AutoCAD SHX Text
SCHEDULED DOOR FRAME
AutoCAD SHX Text
SCHEDULED DOOR TYPE
AutoCAD SHX Text
JAMB DETAIL - INTERIOR AT EXISTING WALL (TYP.) SCALE: N.T.S.
AutoCAD SHX Text DOOR APPROACH AND CLEARANCES DETAIL Scale: N.T.S
AutoCAD SHX Text
DEPT. OF PUBLIC WORKS
AutoCAD SHX Text
PARKS AND RECREATION WASHINGTON SQUARE ADDITION DOOR AND WALL DETAILS
AutoCAD SHX Text
METAL/STEEL STUDS ON 16" O/C (TYP.)
AutoCAD SHX Text
METAL BOTTOM PLATE
AutoCAD SHX Text
NEW/EXIST. FLOORING
AutoCAD SHX Text
NEW/EXIST. CEILING
AutoCAD SHX Text 4"
AutoCAD SHX Text
WALL DETAIL (TYP.) SCALE: N.T.S.
AutoCAD SHX Text
METAL TOP PLATE
AutoCAD SHX Text
5/8" DRYWALL
AutoCAD SHX Text
UNFACED R-13 INSULATION (TYP.)
AutoCAD SHX Text
WOOD BASEBOARD (TYP.)
AutoCAD SHX Text NOTES 1. TOP OF NEW WALLS SHALL TERMINATE 4" ABOVE THE LEVEL OF THE NEW AND/OR EXISTING CEILING, TOP OF NEW WALLS SHALL TERMINATE 4" ABOVE THE LEVEL OF THE NEW AND/OR EXISTING CEILING, INCLUDING CORNERS AND OPENINGS. ALL NEW WALLS SHALL BE FIRMLY BRACED TO THE UNDERSIDE OF THE METAL ROOF FRAMING TRUSSES EVERY 4'-0", NO MATTER THE LOCATION OF THE NEW WALL. 2. METAL TOP PLATE SHALL BE SCREWED INTO THE UNDERSIDE OF THE METAL ROOF FRAMING TRUSSES METAL TOP PLATE SHALL BE SCREWED INTO THE UNDERSIDE OF THE METAL ROOF FRAMING TRUSSES WITH THE APPROPRIATE HARDWARE. 3. METAL BOTTOM PLATE SHALL BE ANCHORED INTO THE FLOORING WITH THE APPROPRIATE HARDWARE. METAL BOTTOM PLATE SHALL BE ANCHORED INTO THE FLOORING WITH THE APPROPRIATE HARDWARE. 4. NEW WALLS WILL HAVE METAL STUDS ON 16" CENTER AND FEATURE A 1 HOUR FIRE RATING. NEW WALLS WILL HAVE METAL STUDS ON 16" CENTER AND FEATURE A 1 HOUR FIRE RATING. 5. WHERE NEWLY INSTALLED RECEPTACLES AND/OR DATA OUTLETS ARE INSTALLED 64" OR 84" ABOVE WHERE NEWLY INSTALLED RECEPTACLES AND/OR DATA OUTLETS ARE INSTALLED 64" OR 84" ABOVE FINISHED FLOOR CONTRACTOR TO INSTALL APPROPRIATE BLOCKING BETWEEN METAL STUDS TO SUPPORT DISPLAY UNIT. SEE SHEETS E-101 AND E-102 LOCATIONS OF RECEPTACLES AND DATA OUTLETS. 6. UNFACED R-13 INSULATION TO BE INSTALLED BETWEEN EACH METAL STUD SPACING IN ALL NEW WALLS UNFACED R-13 INSULATION TO BE INSTALLED BETWEEN EACH METAL STUD SPACING IN ALL NEW WALLS UNLESS OTHER WISE NOTED. 7. DRYWALL: DRYWALL: 7.1. RESTROOM RESTROOM 7.1.1. TO HAVE 5/8" MOISTURE-RESISTANT DRYWALL EVERYWHERE.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .