PR_-_Scope_of_Work_-_SR_2640_-_8-20-2024_(Drawings).pdf

PDF 5 MB Posted

Attached to
Pole Barn at Walton Ranch
Solicitation number
242640MKM
Issued by
Sarasota County, Florida

About this file

These architectural drawings are for the Walton Ranch Preserve Pole Barn project for Sarasota County Parks, located at 7020 Toledo Blade Boulevard in North Port, Florida. The documents include three site plans and elevation drawings: a pre-storm event site plan, pre-storm event elevations, and a mitigation plan site plan and elevations, all dated July 18, 2024. The plans detail a pole barn structure with multiple components including offices, workshop, storage areas, and specific replacement elements such as roof structures, concrete floors, electrical outlets, exterior doors, overhead light fixtures, and exterior lamps.

The drawings provide comprehensive technical specifications for reconstructing the pole barn after hurricane damage, with specific measurements and structural details. The mitigation plan indicates modifications from the original structure, including changes to roof coverage (new metal roof enclosed structure of 1270 sq ft), post mounting, concrete flooring (2400 sq ft of steel reinforced 6" thick concrete), and electrical configurations. The plans show a 110'-8½" long structure with various section widths, multiple rooms, and standardized features like 3' on center typical spacing, 12' clearance open structures, and consistent door and lighting configurations across different elevations.

View the file

Other files

File Type Posted
242640MKM__Disaster_Funded_Provisions.pdf PDF
242640MKM__Solicitation_Documents.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

110'-81 2"

13'-0" O.C., TYP.

34'-5"

14'-101 2"

14'-101 2"

11'-10"

29'-1"10'-0"

3'-0" O.C., TYP.

30'-101 2"

16'-5"

6'-0"

6'-0"

21'-1"12'-1" 77'-6"

SCALE:

0' 5' 10'

1"=10' 11"x17" ORIGINAL SCALE IF ALTERED

(21) 8x8 posts

(3) 4x4 posts

101 sf concrete floor, 6" thickness

344 sf concrete floor, 6" thickness

3' x 10' built-in steel work table

(4) 220-V electrical outlets, (1) at every other center post

4 8

898 sf concrete floor, 6" thickness53940 sf total roof area (structure and metal roofing)

REPLACEMENT ITEMS

WALTON RANCH PRESERVE

POLE BARN SITE PLAN (PRE-STORM EVENT)

July 18, 2024 workshop office storage office covered storage

(2) exterior doors @ 36" wide x 80" high

(1) exterior door @ 28" wide x 80" high11

(12) overhead light fixtures, (1) centered over each bay9

(1) pair of exterior doors @ 66" wide x 120" high each12

SARASOTA COUNTY PARKS | 7020 Toledo Blade Blvd, North Port, FL 34289

(2) shielded exterior lamps, (1) centered at each gable13

34'-51

30'-51 2"

14'-11" 14'-11"

40'-5" 30'-5"

11'-11 2"

6'-0"

10'-0"

110'-81 2"

13'-0" O.C., TYP.

SCALE:

0' 5' 10'

1"=10' 11"x17" ORIGINAL SCALE IF ALTERED

(21) 8x8 posts

(3) 4x4 posts

101 sf concrete floor, 6" thickness

344 sf concrete floor, 6" thickness

3' x 10' built-in steel work table

(4) 220-V electrical outlets at every other center post

4 8

898 sf concrete floor, 6" thickness53940 sf total roof area (structure and metal roofing)

REPLACEMENT ITEMS

WALTON RANCH PRESERVE

POLE BARN ELEVATIONS (BEFORE STORM EVENT)

July 18, 2024

(2) exterior doors @ 36" wide x 80" high

(1) exterior door @ 28" wide x 80" high11

(12) overhead light fixtures, (1) centered over each bay9

(1) pair of exterior doors @ 66" wide x 120" high each12

12 10

WEST ELEVATION SOUTH ELEVATION

EAST ELEVATION NORTH ELEVATION

SARASOTA COUNTY PARKS | 7020 Toledo Blade Blvd, North Port, FL 34289

(2) shielded exterior lamps, (1) centered at each gable13

110'-81

13'-0" O.C., TYP.

34'-5"

14'-101 2"

14'-101 2"

11'-10"

29'-1"10'-0"

3'-0" O.C., TYP.

30'-101 2"

16'-5"

6'-0"

6'-0"

21'-1"12'-1" 77'-6"

SCALE:

0' 5' 10'

1"=10' 11"x17" ORIGINAL SCALE IF ALTERED

(21) 8x8 posts, surface mount to concrete footings

(3) 4x4 posts, , surface mount to concrete footings

101 sf concrete floor, steel reinforced, 6" thickness new metal roof over open structure, 12' clearance (2890 sf)

3' x 10' built-in steel work table

(4) 220-V/110-V electrical outlets, (1) every other center post

4 8

2400 sf concrete floor, steel reinforced, 6" thickness5new metal roof over enclosed structure (1270 sf)

REPLACEMENT ITEMS

WALTON RANCH PRESERVE

POLE BARN SITE PLAN (MITIGATION PLAN)

July 18, 2024 workshop office storage office covered storage

(2) exterior doors @ 36" wide x 80" high

(1) exterior door @ 28" wide x 80" high11

(12) overhead light fixtures, (1) centered over each bay9

(1) pair of exterior doors @ 66" wide x 120" high each12

SARASOTA COUNTY PARKS | 7020 Toledo Blade Blvd, North Port, FL 34289

34'-51

30'-51 2"

14'-11" 14'-11"

12'-0"

40'-5" 30'-5"

11'-11 2"

6'-0"

10'-0"

110'-81 2"

13'-0" O.C., TYP.

83'-10"

4'-0"

12'-0"

SCALE:

0' 5' 10'

1"=10' 11"x17" ORIGINAL SCALE IF ALTERED

WALTON RANCH PRESERVE

POLE BARN ELEVATIONS (MITIGATION PLAN)

July 18, 2024

10 11

12 10

WEST ELEVATION SOUTH ELEVATION

EAST ELEVATION NORTH ELEVATION

SARASOTA COUNTY PARKS | 7020 Toledo Blade Blvd, North Port, FL 34289

(21) 8x8 posts, surface mount to concrete footings

(3) 4x4 posts, , surface mount to concrete footings

101 sf concrete floor, steel reinforced, 6" thickness new metal roof over open structure, 12' clearance (2890 sf)

3' x 10' built-in steel work table

(4) 220-V/110-V electrical outlets, (1) every other center post

4 8

2400 sf concrete floor, steel reinforced, 6" thickness5new metal roof over enclosed structure (1270 sf)

REPLACEMENT ITEMS

(2) exterior doors @ 36" wide x 80" high

(1) exterior door @ 28" wide x 80" high11

(12) overhead light fixtures, (1) centered over each bay9

(1) pair of exterior doors @ 66" wide x 120" high each12

File details come from the government source that posted it. Updated .