PR_9469_Demo_of_Old_Unit_1_and_2_Breeching_Duct_IRPAddendum_5.pdf
PDF 245 KB Posted
- Solicitation number
- PR9469
- Issued by
- Florida
About this file
This document is an Addendum #5 to a Request for Quote issued by the Orlando Utilities Commission (OUC), a Florida-based utility authority, for the demolition of the Old Unit #1 and Unit #2 breeching duct at the Indian River Plant in Titusville, Florida. The scope of work requires complete demolition and removal of the deteriorated breeching duct from flange to flange, including crane rental, rigging, scaffolding, material disposal, and support for existing lighting cables using new stainless-steel cable that is properly grounded. The original quotation due date of September 30, 2026 at 2:00 p.m. local time has been extended to December 16, 2026 at 2:00 p.m. due to current workload and the volume of questions received. A non-mandatory pre-response conference was scheduled for September 16, 2026 at 9:00 a.m. EST at the facility, and bidders are encouraged to attend the site visit and bring subcontractors to assess conditions. No further questions are being accepted at this point in time, and no additional site visits will be held. Responses to previously submitted questions will be answered via addendum two to three weeks prior to the new due date.
Contractors must submit both a fixed-cost proposal and a Time and Material estimate priced per day, with the all-inclusive daily rate to cover crane rental and all subcontractor expenses. Quotations should be submitted electronically via VendorLink or emailed to Jonathan McLester, Buyer of Record, at jmclester@ouc.com. Bidders must acknowledge receipt of all addenda in their quote submittal or risk having their quote considered non-responsive. Submittal requirements include a completed quotation response, acknowledgement of the Sworn Statement on Public Entity Crimes and Scrutinized Companies under Florida Statutes Section 287.133(3)(a) and 287.135, a Dispute Disclosure form, and a W-9 form. Upon award, contractors must provide proof of General Liability, Worker's Compensation, and Automotive insurance, and suppliers must affirm compliance with Florida Statutes and confirm no allegations, defaults, lawsuits, or investigations have been initiated against them within the last five years. OUC reserves the right to award items to one or more suppliers or make no award. No communication between the supplier, their employees, or subcontractors concerning this RFP is permitted with anyone within OUC except the buyer of record.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PR 9469
DEMOLITION OF OLD UNIT 1 & UNIT 2 BREECHING DUCT AT IRP
ADDENDUM #5
DATED: November 3, 2026
This is an Addendum to and shall be considered as part of the original RFQ package for the above referenced proposal. In your Quote submittal, you MUST note that all Addenda were received OR YOUR QUTOE MAY BE CONSIDERED NON- RESPONSIVE. If additional information is required regarding this RFQ, please feel free to contact the buyer of record at jmclester@ouc.com. Thank you for your participation in this RFQ.
QUOTE DUE DATE AND TIME CHANGE
Due to current workload, and the volume of questions received to date, the due date and time for quote submittals is extended to December 16, 2026 at 2:00 p.m. Responses to questions received will be answered via addendum two to three weeks prior to this new due date and time.
No further questions are being accepted at this point in time, and no additional site-visits will be held. All quotes should be submitted electronically via VendorLink or to jmclester@ouc.com.
Note: There shall be no communication between the supplier, their employees or subcontractors concerning this RFP to anyone within OUC except the buyer of record.
Sincerely, Jonathan McLester, PMP, CPPO, CPPB Buyer | Strategic Sourcing Orlando Utilities Commission | Supply Chain Management
(407) 434–2217 | jmclester@ouc.com | Reliable Plaza | 100 West Anderson Street | Orlando, FL 32801
Orlando Utilities Commission P.O. Box 3193 Orlando Florida 32802 Reliable Plaza : 100 W Anderson St. Orlando, FL 32802 Phone: 407.434.2217 Website: www.ouc.com mailto:jmclester@ouc.com mailto:jmclester@ouc.com mailto:jmclester@ouc.com http://www.ouc.com/
| Orlando Utilities Commission |
| DEMOLITION OF OLD UNIT 1 & UNIT 2 BREECHING DUCT AT IRP |
| ADDENDUM #5 |
File details come from the government source that posted it. Updated .