This is a Request for Quotation (RFQ) issued by the Maine Department of Environmental Protection for the purchase and installation of two Power Take-Off (PTO) units and hydraulic pump systems for oil and hazardous material response vehicles. The solicitation seeks complete systems including all necessary hardware, components, and installation services on two specified Ford F-350 trucks: a 2009 model with a 6.4-liter diesel engine and a 2011 model with a 6.7-liter diesel engine. Both systems must deliver a minimum hydraulic output of 13.1 GPM at 1200 engine RPM and include 30-gallon minimum capacity reservoirs with dual-circuit plumbing capabilities. The systems will power product transfer pumps, oil spill recovery equipment, and auxiliary equipment including air compressors. Bidders must submit warranty details with their proposals, and all questions regarding the RFQ must be submitted through the designated Question and Answer link on the Solicitation Details View page.
Bid pricing should include all hardware, components, and installation costs. Each system requires dual-circuit capability with open center spool valves and speed control valves, case drain requirements, and must be delivered complete and ready to operate. Custom fabricated tanks for under-deck mounting may be necessary. The State of Maine reserves the right to pay by check, electronic funds transfer (EFT), or procurement card. State statute (9-A MRSA 8-303(2)) prohibits sellers from imposing surcharges on credit or debit card purchases. No specific response deadline, award date, or contract term information is provided in the solicitation materials.
Text of this file
Power Take - Off & Pump for Oil & Hazardous Material Response vehicles
The Maine Department of Environmental Protection is seeking bids for the purchase of two Power Take-Off units (PTOs) and Pumps. It is the intent to use the hydraulic drive units to operate product transfer pumps, oil spill recovery equipment and auxiliary equipment including air compressors. Examples of the types of oil and chemical recovery equipment Emergency Responders use and general specification are listed in Appendix A. Your bid pricing should include the cost of all necessary hardware, associated components and installation on the two response vehicles listed below.
Truck A) 2009 F-350 SD, Dual rear wheels, Super Cab. 4x4, 6.4 liter diesel engine, 1300GVW, 186” wheel base, cab to axle = 84”. Auto Torq Shift #5R110W 5-speed transmission w/ PTO option.
Chelsea Power Take-Off for the Ford TorqShift Transmissions or approved equivalent and Parker Pump or approved equivalent and required accessories and hardware for operation.
· Hydraulic output requirement, minimum: 13.1 GPM @ 1200 Eng. RPM.
- Reservoir w/ 30 gallon minimum capacity or suggested equivalent to ensure proper cooling and system requirements; may require custom fabricated tank for under deck mounting option.
- System plumbed for two circuit capability, one circuit to operate hydraulically driven air compressor (see Appendix A) and the second circuit for auxiliary hydraulic operated equipment (see Appendix A). System should be delivered complete and ready to operate including open center spool valves and speed control valves as needed. System requires a case drain. (System on Truck A is not intended to operate compressor and auxiliary circuit at the same time).
Truck B) 2011 Ford F-350 SD, Dual rear wheels, Regular cab, 4x4. 6.7 liter diesel engine, 13,000GVW, l62”wheel base, cab to axle = 84”, Auto torq shift 6-speed torq select shift transmission w/ PTO option.
Chelsea Power Take-Off for the Ford TorqShift Transmissions or approved equivalent and Parker Pump or approved equivalent and required accessories and hardware for operation.
· Hydraulic output requirement: 13.1 GPM @ 1200 Eng. RPM
· Reservoir w/30 gallon minimum capacity or equivalent to ensure proper cooling and system
· requirements; may require custom fabricated tank for under deck mounting option.
System plumbed for two circuit capability and should be delivered complete and ready to
· operate including open center spool valves and speed control valves as needed.
· System requires a case drain.
Note: Please attach warranty details to your response.
If you have a question regarding this RFQ, you must submit your questions thru the Question and Answer link on the Solicitation Details View page. Your answer will appear there as well. It is the vendors responsibility to log in to view all questions and answers posted there. Questions and Answers obtained any other way will not be valid for this RFQ.
PAYMENT METHOD: The State of Maine reserves the right to pay for goods purchased through this solicitation by any of several available means, which include but may not be limited to check, EFT, and/or procurement card. Bidders are advised that state statute precludes sellers from imposing a surcharge on credit or debit card purchases (text follows).
9-A MRSA §8-303 (2): A seller in a sales transaction may not impose a surcharge on a cardholder who elects to use a credit card or debit card in lieu of payment by cash, check or similar means.
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation_terms.doc | DOC document | |
| Appendix A.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .