Plans_Part 2 21164.pdf

PDF 2 MB Posted

Attached to
472/21164. 3JBB; Baraga CF - Building 500 HVAC Upgrades
Solicitation number
RFQ 171 220000000349 2
Issued by
Arenac County, Michigan

About this file

This is a preliminary construction plan document for the State of Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division, prepared by OHM Advisors for an HVAC upgrade project at the Baraga Correctional Facility located at 424 Hancock Street, Hancock, Michigan 49930. The project involves Building 500 (Warehouse) mechanical and electrical upgrades, with the OHM project number 472/21164.JBB 472A MF, issued May 13, 2022. The document comprises electrical and mechanical plan sheets including demolition plans, first floor electrical plans, mezzanine electrical plans, and roof electrical plans. The plans reference two existing electrical panels: Panel RP-J (208/120V, 3-phase, 4-wire, 100A, multi-circuit breaker, 30-circuit, surface mount, located on the first floor in Telephone Room 23) and Panel RP-X (208/120V, 3-phase, 4-wire, 100A, multi-circuit breaker, 24-circuit, surface mount, also located on the first floor in Telephone Room 23). Roof-mounted RTU-2 and RTU-3 units are identified for the HVAC upgrade work.

The document contains general demolition notes and electrical demolition key notes for the project scope. The plans include multiple sheets covering warehouse building 500 components across different floor levels and roof areas, with corresponding mechanical details, schedules, and site key plans. No specific contract pricing, bidding requirements, award dates, or contract terms are detailed within this preliminary construction plan document, as it serves primarily as the technical design specification for the proposed HVAC and electrical work at the correctional facility.

View the file

Other files

File Type Posted
Advertisement 21164.pdf PDF
Addendum 1 21164.pdf PDF
Specifications 21164.pdf PDF
Plans_Part 1 21164.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C

L

C

L

M

I/C

B

M

PS

P

DC

DO

ES

R

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

PR

EL

IM

IN

AR

Y

CO

NS

TR

UC

TI

ON

FI

NA

L R

EC

OR

D

DA

TE

IS

SU

ED

F

OR

AC

CO

UN

TI

NG

T

EM

P:

DT

MB

F

ILE

N

UM

BE

R:

ID

EN

TI

FI

CA

TI

ON

N o.

SH

EE

T

DE

SI

GN

ED

DR

AW

N

CH

EC

KE

D

AP

PR

OV

ED

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A

CI

LI

TI

ES

A

D M

IN

IS

TR

A

TI

O

N D

ES

IG

N A

N D

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

OHM PROJECT No.

2/2

.JB

B

2A

MF

Ma int Pr oj

M

AY

SW SW LM

M

LM

M

Va lue

Va lue

E-

BU

ILD

IN

G

0 H

VA

C

UP

GR

AD

ES

DE

PA

RT

ME

NT

O F

CO

RR

EC

TI

ON

S

BA

RA

GA

C

OR

RE

CT

IO

NA

L F

AC

ILI

TY

7136220030

GE

NE

RA

L E

LE

CT

RI

CA

L I

NF

OR

MA

TI

ON

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH 906.482.0535 | F 906.482.6453

1 1

B

A

1RTU-3

RTU-2

GENERAL DEMOLITION NOTES

ELECTRICAL DEMOLITION KEY NOTES

R

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

PR

EL

IM

IN

AR

Y

CO

NS

TR

UC

TI

ON

FI

NA

L R

EC

OR

D

DA

TE

IS

SU

ED

F

OR

AC

CO

UN

TI

NG

T

EM

P:

DT

MB

F

ILE

N

UM

BE

R:

ID

EN

TI

FI

CA

TI

ON

N o.

SH

EE

T

DE

SI

GN

ED

DR

AW

N

CH

EC

KE

D

AP

PR

OV

ED

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A

CI

LI

TI

ES

A

D M

IN

IS

TR

A

TI

O

N D

ES

IG

N A

N D

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

OHM PROJECT No.

2/2

.JB

B

2A

MF

Ma int Pr oj

M

AY

SW SW LM

M

LM

M

Va lue

Va lue

ED

BU

ILD

IN

G

0 H

VA

C

UP

GR

AD

ES

DE

PA

RT

ME

NT

O F

CO

RR

EC

TI

ON

S

BA

RA

GA

C

OR

RE

CT

IO

NA

L F

AC

ILI

TY

7136220030

W

AR

EH

OU

SE

B

UI

LD

IN

G

0 R

OO

F

EL

EC

TR

IC

AL

D

EM

OL

IT

IO

N

PL

AN

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH 906.482.0535 | F 906.482.6453

KEYPLAN

WAREHOUSE 500 ROOF ELECTRICAL PLAN1

ELECTRICAL DEMOLITION KEY NOTES

GENERAL DEMOLITION NOTES

RP-J DESCRIPTION: EXISTING PANEL SURFACE MOUNT, 208/120V, 3ɸ, 4W, 100A, MCB, 30 CIRCUIT, LOCATED ON FIRST FLOOR IN

TELEPHONE RM 23

RP-X DESCRIPTION: EXISTING PANEL SURFACE MOUNT, 208/120V, 3ɸ, 4W, 100A, MCB, 24 CIRCUIT, LOCATED ON FIRST FLOOR IN

TELEPHONE RM 23

R

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

PR

EL

IM

IN

AR

Y

CO

NS

TR

UC

TI

ON

FI

NA

L R

EC

OR

D

DA

TE

IS

SU

ED

F

OR

AC

CO

UN

TI

NG

T

EM

P:

DT

MB

F

ILE

N

UM

BE

R:

ID

EN

TI

FI

CA

TI

ON

N o.

SH

EE

T

DE

SI

GN

ED

DR

AW

N

CH

EC

KE

D

AP

PR

OV

ED

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A

CI

LI

TI

ES

A

D M

IN

IS

TR

A

TI

O

N D

ES

IG

N A

N D

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

OHM PROJECT No.

2/2

.JB

B

2A

MF

Ma int Pr oj

M

AY

SW SW LM

M

LM

M

Va lue

Va lue

ED

BU

ILD

IN

G

0 H

VA

C

UP

GR

AD

ES

DE

PA

RT

ME

NT

O F

CO

RR

EC

TI

ON

S

BA

RA

GA

C

OR

RE

CT

IO

NA

L F

AC

ILI

TY

7136220030

EL

EC

TR

IC

AL

S

CH

ED

UL

E

DE

MO

LIT

IO

N

424 HANCOCK STREET

R

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

PR

EL

IM

IN

AR

Y

CO

NS

TR

UC

TI

ON

FI

NA

L R

EC

OR

D

DA

TE

IS

SU

ED

F

OR

AC

CO

UN

TI

NG

T

EM

P:

DT

MB

F

ILE

N

UM

BE

R:

ID

EN

TI

FI

CA

TI

ON

N o.

SH

EE

T

DE

SI

GN

ED

DR

AW

N

CH

EC

KE

D

AP

PR

OV

ED

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A

CI

LI

TI

ES

A

D M

IN

IS

TR

A

TI

O

N D

ES

IG

N A

N D

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

OHM PROJECT No.

2/2

.JB

B

2A

MF

Ma int Pr oj

M

AY

SW SW LM

M

LM

M

Va lue

Va lue

E-

BA

RA

GA

C F

HV

AC

U

PG

RA

DE

S

DE

PA

RT

ME

NT

O F

CO

RR

EC

TI

ON

S

BA

RA

GA

C

OR

RE

CT

IO

NA

L F

AC

ILI

TY

7136220030

W

AR

EH

OU

SE

B

UI

LD

IN

G

0 F

IR

ST

F

LR

E

LE

CT

RI

CA

L P

LA

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH 906.482.0535 | F 906.482.6453

WAREHOUSE 500 FIRST FLR ELECTRICAL PLAN1

R

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

PR

EL

IM

IN

AR

Y

CO

NS

TR

UC

TI

ON

FI

NA

L R

EC

OR

D

DA

TE

IS

SU

ED

F

OR

AC

CO

UN

TI

NG

T

EM

P:

DT

MB

F

ILE

N

UM

BE

R:

ID

EN

TI

FI

CA

TI

ON

N o.

SH

EE

T

DE

SI

GN

ED

DR

AW

N

CH

EC

KE

D

AP

PR

OV

ED

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A

CI

LI

TI

ES

A

D M

IN

IS

TR

A

TI

O

N D

ES

IG

N A

N D

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

OHM PROJECT No.

2/2

.JB

B

2A

MF

Ma int Pr oj

M

AY

SW SW LM

M

LM

M

Va lue

Va lue

E-

BA

RA

GA

C F

HV

AC

U

PG

RA

DE

S

DE

PA

RT

ME

NT

O F

CO

RR

EC

TI

ON

S

BA

RA

GA

C

OR

RE

CT

IO

NA

L F

AC

ILI

TY

7136220030

W

AR

EH

OU

SE

B

UI

LD

IN

G

0 M

EZ

ZA

NI

NE

E

LE

CT

RI

CA

L P

LA

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH 906.482.0535 | F 906.482.6453

WAREHOUSE 500 MEZZANINE ELECTRICAL PLAN1

1 1

B

A

RTU-3

RTU-2

R

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

PR

EL

IM

IN

AR

Y

CO

NS

TR

UC

TI

ON

FI

NA

L R

EC

OR

D

DA

TE

IS

SU

ED

F

OR

AC

CO

UN

TI

NG

T

EM

P:

DT

MB

F

ILE

N

UM

BE

R:

ID

EN

TI

FI

CA

TI

ON

N o.

SH

EE

T

DE

SI

GN

ED

DR

AW

N

CH

EC

KE

D

AP

PR

OV

ED

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A

CI

LI

TI

ES

A

D M

IN

IS

TR

A

TI

O

N D

ES

IG

N A

N D

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

OHM PROJECT No.

2/2

.JB

B

2A

MF

Ma int Pr oj

M

AY

SW SW LM

M

LM

M

Va lue

Va lue

E-

BU

ILD

IN

G

0 H

VA

C

UP

GR

AD

ES

DE

PA

RT

ME

NT

O F

CO

RR

EC

TI

ON

S

BA

RA

GA

C

OR

RE

CT

IO

NA

L F

AC

ILI

TY

7136220030

W

AR

EH

OU

SE

B

UI

LD

IN

G

0 R

OO

F

EL

EC

TR

IC

AL

P

LA

N

424 HANCOCK STREET

HANCOCK, MICHIGAN 49930

PH 906.482.0535 | F 906.482.6453

WAREHOUSE 500 ROOF ELECTRICAL PLAN1

RP-J DESCRIPTION: EXISTING PANEL SURFACE MOUNT, 208/120V, 3ɸ, 4W, 100A, MCB, 30 CIRCUIT, LOCATED ON FIRST FLOOR IN

TELEPHONE RM 23

RP-X DESCRIPTION: EXISTING PANEL SURFACE MOUNT, 208/120V, 3ɸ, 4W, 100A, MCB, 24 CIRCUIT, LOCATED ON FIRST FLOOR IN

TELEPHONE RM 23

R

ARCHITECTS. ENGINEERS. PLANNERS

OHM-ADVISORS.COM

PR

EL

IM

IN

AR

Y

CO

NS

TR

UC

TI

ON

FI

NA

L R

EC

OR

D

DA

TE

IS

SU

ED

F

OR

AC

CO

UN

TI

NG

T

EM

P:

DT

MB

F

ILE

N

UM

BE

R:

ID

EN

TI

FI

CA

TI

ON

N o.

SH

EE

T

DE

SI

GN

ED

DR

AW

N

CH

EC

KE

D

AP

PR

OV

ED

D

EP

A

RT

M

EN

T O

F

TE

CH

N

O

LO

G Y

, M A

N A

G

EM

EN

T

A N

D B

U D

G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

P . L

A C

H , R

A , D

IR

EC

TO

R

ST

A

TE

F

A

CI

LI

TI

ES

A

D M

IN

IS

TR

A

TI

O

N D

ES

IG

N A

N D

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

OHM PROJECT No.

2/2

.JB

B

2A

MF

Ma int Pr oj

M

AY

SW SW LM

M

LM

M

Va lue

Va lue

E-

BU

ILD

IN

G

0 H

VA

C

UP

GR

AD

ES

DE

PA

RT

ME

NT

O F

CO

RR

EC

TI

ON

S

BA

RA

GA

C

OR

RE

CT

IO

NA

L F

AC

ILI

TY

7136220030

EL

EC

TR

IC

AL

S

CH

ED

UL

ES

424 HANCOCK STREET

Sheets and Views
DT COVER SHEET - BLDG 500
S-101 MEZZANINE PLAN
7136220030-SV_BLDG 500 MEZZ
S-102 WAREHOUSE 500 ROOF FRAMING PLAN
7136220030-SV_BLDG 500 MEZZ
M-001 GENERAL MECHANICAL INFORMATION
7136220030-VM_MECHANICAL DETAILS
MD101 WAREHOUSE 500 FIRST FLR MECHANICAL DEMOLITION PLAN
7136220030-VM_500_FIRST FLR MECH PLAN
7136220030-V_SITE KEY PLAN
7136220030-VM_MECHANICAL DETAILS
MD102 WAREHOUSE 500 ROOF MECHANICAL DEMOLITION PLAN
7136220030-VM_500_ROOF PLAN
7136220030-V_SITE KEY PLAN
7136220030-VM_MECHANICAL DETAILS
M-101 WAREHOUSE 500 FIRST FLR MECHANICAL PLAN
7136220030-VM_500_FIRST FLR MECH PLAN
7136220030-V_SITE KEY PLAN
M-102 WAREHOUSE 500 MEZZANINE MECHANICAL PLAN
7136220030-V_SITE KEY PLAN
7136220030-VM_500_MEZZ MECH PLAN
M-103 WAREHOUSE 500 ROOF MECHANICAL PLAN
7136220030-VM_500_ROOF PLAN
7136220030-V_SITE KEY PLAN
M-301 MECHANICAL DETAILS
7136220030-VM_MECHANICAL DETAILS
E-001 GENERAL ELECTRICAL INFORMATION
7136220030-VE_ELECT DETAILS
ED101 WAREHOUSE BUILDING 500 ROOF ELECTRICAL DEMOLITION PLAN
7136220030-VE_500_ROOF ELECT PLAN
7136220030-V_SITE KEY PLAN
7136220030-Demo Notes
ED601 ELECTRICAL SCHEDULE DEMOLITION
7136220030-Demo Notes__only on bldg 500 e-101
E-101 WAREHOUSE BUILDING 500 FIRST FLR ELECTRICAL PLAN
7136220030-VE_500_FIRST FLOOR ELECT PLAN
7136220030-V_SITE KEY PLAN
E-102 WAREHOUSE BUILDING 500 MEZZANINE ELECTRICAL PLAN
7136220030-VE_500_MEZZ ELECT PLAN
7136220030-V_SITE KEY PLAN
E-103 WAREHOUSE BUILDING 500 ROOF ELECTRICAL PLAN
7136220030-VE_500_ROOF ELECT PLAN
7136220030-V_SITE KEY PLAN
E-601 ELECTRICAL SCHEDULES
7136220030-Demo Notes__only on bldg 500 e-101

File details come from the government source that posted it. Updated .