About this file
This file contains architectural and engineering plans from OHM Advisors for an ADA Egress Ramps Construction project at the Baraga Correctional Facility for the State of Michigan Department of Technology, Management and Budget (DTMB) and Department of Corrections. The project involves constructing ADA-compliant egress ramps at Housing Units 5 and 6 of the facility located at 13924 Wadaga Rd, Baraga, MI. The plans detail removal of existing concrete sidewalks, installation of new ADA ramps with handrails, drainage improvements, electrical modifications for door monitoring systems, and associated site restoration work. The construction documents are dated February 25, 2021 with DTMB File No. 472/19526.JBB.
The plans include detailed site layouts, grading plans, and construction details for both housing units. At Unit 5, approximately 180 SYD of concrete removal and 247 SYD of earth disturbance is specified, along with new storm drainage infrastructure including 32 feet of 8" PVC culvert. Unit 6 work involves 531 SYD of earth disturbance and approximately 147 SYD of new concrete walkway. Both areas require protection of existing utilities and light poles, installation of inlet filters for erosion control, and restoration of disturbed areas with topsoil, seed and mulch.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Plans - Part 2 19526.pdf | ||
| Addendum No. 1.pdf | ||
| Plans - Part 3 19526.pdf | ||
| Specifications 19526.pdf | ||
| Advertisement 19526.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H an co ck
S tre et
H an co ck
, M I 4 p (9
) 4
-0 f
(9
) 4
-6
Ar ch ite ct s.
E ng in ee rs
. P la nn er s.
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
DT
AD
A
EG
RE
SS
R
AM
PS
C O
NS
TR
UC
TI
O N
DE
PA
RT
M
EN
T
O F
CO
RR
EC
TI
O
NS
BA
RA
G A
TI
TL
E
SH
EE
T
GENERAL NOTES:
1. GENERAL NOTES APPLY TO ALL DRAWINGS
2. DO NOT SCALE DRAWINGS. ANY DIMENSIONAL INFORMATION REQUIRED WHICH IS
NOT INDICATED ON DRAWING DIMENSION STRINGS SHALL BE OBTAINED FROM THE
ARCHITECT.
3. DIMENSIONS SHOWN ARE FINISH SURFACE OF EXISTING CONSTRUCTION, UNLESS
NOTED OTHERWISE.
4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS (I.E.
EXISTING MATERIALS, FRAMING MEMBER SIZES AND LOCATIONS, METHODS OF
CONSTRUCTION). IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT BEFORE
PROCEEDING WITH WORK.
5. CONTRACTOR SHALL PAY ALL PERMIT FEES.
6. CONTRACTOR SHALL MAINTAIN THE IMMEDIATE CONSTRUCTION SITE IN A SECURE,
CLEAN AND SAFE MANNER.
7. PROTECTION: CONTRACTORS SHALL BE SOLELY RESPONSIBLE FOR TAKING ALL
STEPS NECESSARY TO PROTECT THE PUBLIC FROM INJURY AND ADJACENT PROPERTY
DAMAGES DURING CONSTRUCTION.
8. REPAIR ALL EXISTING CONSTRUCTION AFFECTED BY NEW WORK TO ITS ORIGINAL
CONDITION.
CIVIL
DRAWING INDEX:
I Certify That The Electrical Plans Were Prepared Under My Direct Supervision
DT TITLE SHEET
I Certify That The Architectural Plans Were Prepared Under My Direct Supervision
I Certify That The Structural Plans Were Prepared Under My Direct Supervision
I Certify That The Civil Plans Were Prepared Under My Direct Supervision
ARCHITECTURALSTRUCTURAL ELECTRICAL
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
STATE OF MICHIGAN
ROBERT C. HALL, RA, NCARB, DIRECTOR
STATE FACILITIES ADMINISTRATION
DESIGN AND CONSTRUCTION DIVISION
STATE OF MICHIGAN
HEIDI WASHINGTON , Director
DEPARTMENT OF CORRECTIONS
OHM PROJECT No.
DATE:
DTMB File No.
ACCOUNTING TEMP
7136200060
25 FEB 2021
CONSTRUCTION DOCUMENTS
472/19526.JBB
472AMFMAINTPROJ
BARAGA CORRECTIONAL FACILITY
ADA EGRESS RAMPS CONSTRUCTION
13924 WADAGA RD.
BARAGA, MI 49908
A-101 HOUSING UNIT 5 RAMP PLAN
A-102 HOUSING UNIT 6 RAMP PLAN
A-103 DETAILS AND SCHEDULES
S-001 STRUCTURAL STANDARDS
S-002 STRUCTURAL DETAILS
S-003 STRUCTURAL DETAILS
S-004 STRUCTURAL DETAILS
E-001 GENERAL ELECTRICAL INFO
E-101 HOUSING UNIT 5 ELECTRICAL PLANS
E-102 HOUSING UNIT 6 ELECTRICAL PLANS
E-301 ELECTRICAL DETAILS
E-302 ELECTRICAL DETAILS
E-303 HOUSING UNIT 5 DOOR MONITORING SCHEMATIC
E-304 HOUSING UNIT 6 DOOR MONITORING SCHEMATIC
E-401 ELECTRICAL SCHEDULES
C-001 NOTES/ LEGEND
C-120 UNIT 5 REMOVAL PLAN
C-121 UNIT 6 REMOVAL PLAN
C-130 UNIT 5 PROPOSED SITE PLAN
C-131 UNIT 6 PROPOSED SIRE PLAN
http://www.ohm-eng.com http://www.ohm-eng.com
FLAMMABLE MATERIAL
HAZARDOUS OR
LIGHT/DECOR LAMP POLE
TRAVERSE POINT
MISCELLANEOUS SYMBOLS
BENCHMARK
USED WITH UNDERGROUND GAS &
ELECTRICAL LINES
USED WITH TELEPHONE &
UTILITY PATTERN
ELECTRICAL *
GAS\OIL
WATER
FIBER OPTIC *
TOPO PATTERN
FENCE
REMOVAL LEGEND
SANITARY
STORM
UNDERGROUND UTILITY
CAUTION - CRITICAL
SIDEWALK REMOVAL
FENCE
CABLE/TELEPHONE *
PROPOSED
STORM
12"
FIBER OPTIC LINES
STRUCTURE NUMBER
WM SAN STM
UTILITY SYMBOLS
STORM MANHOLE
ROUND CATCH BASIN
SANITARY MANHOLE
FIRE HYDRANT
INLET/CATCH BASIN
GATE VALVE & WELL
SPRINKLER HEAD
WATER STOP BOX
GATE VALVE & BOX
12"
EARTH DISTURBANCE
ADJ ADJUST
APPROX APPROXIMATELY
ASPH ASPHALT
B/BANK BOTTOM OF BANK
CONC CONCRETE
CT CURB TRANSITION
C&G CURB AND GUTTER
CVT CITY, VILLAGE, OR TOWNSHIP
DIA DIAMETER
DW DOMESTIC WATER
EA EDGE OF ASPHALT
ELEC ELECTRIC
ELEV ELEVATION
EX EXISTING
F/C FACE OF CURB
FF FINISH FLOOR
FG FINISHED GRADE
FT FEET
HDCP HANDICAP
INV INVERT ELEVATION
OB OBSERVATION WELL
OBS OBSERVED
OH OVERHEAD
OT OVER TOPPING
PROP PROPOSED
R RADIUS
RES RESET
RIM TOP OF UTILITY/DRAINAGE STRUCTURE
ROW RIGHT-OF-WAY
SAN SANITARY
SP SPRING WATER
SQFT SQUARE FEET
STM STORM
SYD SQUARE YARD
TC TOP OF CURB
TELE TELEPHONE
TP TRAVERSE POINT
TS&M TOPSOIL, SEED & MULCH
TYP TYPICAL
T/BANK TOP OF BANK
UG UNDER GROUND
WEL WELL LINES
W# WELL LINE
WM WATER MAIN
WTR WATER
YBT YELLOW BENCH TIE
D
RIPRAP SIZE WHERE 50% OF STONES
ARE LARGER
D
MAX
MAX STONE SIZE / AVG DEPTH OF
RIPRAP
ABBREVIATIONS:
UTILITY NOTES
1. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR THE PROTECTION OF ALL EXISTING
UTILITIES DURING CONSTRUCTION. ALL UTILITIES DAMAGED DURING CONSTRUCTION SHALL BE
REPAIRED WITH LIKE MATERIAL. THE EXACT LOCATION OF EXISTING UTILITIES SHALL BE LOCATED
BY HAND DIGGING.
2. THE UTILITY LOCATIONS ARE BASED ON FIELD OBSERVATIONS AND A CAREFUL REVIEW OF UTILITY
RECORDS. HOWEVER, IT IS NOT POSSIBLE TO DETERMINE THE PRECISE SIZE, LOCATION, DEPTH, PRESSURE, OR ANY OTHER CHARACTERISTICS OF UNDERGROUND UTILITIES, TANKS OR SEPTIC
FIELDS WITHOUT EXCAVATION. THEREFORE, WE CANNOT GUARANTEE THE ACCURACY OR
COMPLETENESS OF THE BURIED UTILITY INFORMATION HEREON SHOWN. THE CONTRACTOR SHALL
HIRE A PRIVATE UTILITY LOCATOR TO LOCATE UTILITIES ON SITE. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO VERIFY THESE UTILITY LOCATIONS PRIOR TO CONSTRUCTION AND MAKE
EVERY EFFORT TO PROTECT AND/OR RELOCATE THEM AS REQUIRED. THE CONTRACTOR SHALL
NOTIFY THE ENGINEER / SURVEYOR AS SOON AS POSSIBLE IN THE EVENT A DISCREPANCY IS
FOUND.
REMOVAL
1. REMOVALS SHALL BE DONE AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER.
2. ANY ADDITIONAL TREE REMOVALS, CLEARING, GRADING, ETC. NEEDED FOR THE CONTRACTOR'S STAGING
AND/OR WORK OPERATIONS SHALL BE COMPLETED AND AREA RESTORED TO THE SATISFACTION OF THE
OWNER WITHOUT ADDITIONAL COMPENSATION.
3. ADDITIONAL WORK OUTSIDE OF THE LIMITS SHOWN ON THE PLAN SHALL BE SUBMITTED TO THE ENGINEER
FOR APPROVAL PRIOR TO STARTING THE ADDITIONAL WORK.
4. MATERIALS REMOVED SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND BE PROPERLY DISPOSED
OF AT AN OFF SITE LOCATION.
DTMB: GENERAL NOTES
1. IN CASE OF DISCREPANCIES BETWEEN THE MDOT STANDARD SPECIFICATIONS AND MICHIGAN
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET (DTMB) DC SPEC, THE DTMB PROVISIONS
CONTROL.
GENERAL NOTES
1. IT IS THE CONTRACTORS RESPONSIBILITY TO SECURE ALL PERMITS AND POST ALL BONDS PRIOR TO
CONSTRUCTION, OR ENSURE THAT ALL REQUIRED PERMITS AND BONDS HAVE BEEN OBTAINED
PRIOR TO CONSTRUCTION.
2. ALL TEMPORARY SOIL EROSION AND SEDIMENTATION CONTROL MEASURES ARE TO BE IN PLACE
PRIOR TO STARTING REMOVALS.
3. THE CONTRACTOR SHALL BE LIABLE FOR ANY DAMAGE TO STREETS, SIDEWALKS, OTHER
STRUCTURES, AND ADJACENT AREAS CAUSED BY DEMOLITION OR HAULING OPERATIONS.
4. THE CONTRACTOR SHALL TAKE ALL NECESSARY ACTIONS TO ENSURE WORKER SAFETY AND
COMPLIANCE WITH MI-OSHA GUIDELINES.
5. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFYING ALL DIMENSIONS PRIOR TO CONSTRUCTION.
ADJUST WORK AS REQUIRED TO MEET FIELD DIMENSIONS AT NO ADDITIONAL COST TO THE OWNER.
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING
WITH WORK.
6. THE IMPROVEMENTS COVERED BY THESE PLANS SHALL BE DONE IN ACCORDANCE WITH
ACCOMPANYING SPECIFICATIONS FOR THIS PROJECT INCLUDING THE 2012 MDOT STANDARD
SPECIFICATIONS FOR CONSTRUCTION AND THE MICHIGAN DEPARTMENT OF CORRECTIONS.
7. THE CONTRACTOR SHALL CONDUCT THEIR OPERATIONS IN SUCH A MANNER AS TO COMPLY WITH
ALL FEDERAL, STATE, AND LOCAL CODES FOR NOISE LEVELS, HOURS OF OPERATION FOR
CONSTRUCTION ACTIVITY, VIBRATIONS, OR ANY OTHER RESTRICTIONS. NO ADDITIONAL
COMPENSATION WILL BE DUE TO THE CONTRACTOR FOR ANY WINTER PROTECTION MEASURES
THAT MAY BE REQUIRED TO COMPLY WITH THE CONTRACT DOCUMENTS.
8. COORDINATION BY THE CONTRACTOR; NO ADDITIONAL COMPENSATION SHALL BE PAID TO THE
CONTRACTOR FOR ANY DELAY OR INCONVENIENCE DUE TO MATERIAL SHORTAGES OR DELAYS DUE
TO THE OPERATIONS OF SUCH OTHER PARTIES DOING WORK INDICATED OR SHOWN ON THE PLANS
OR IN THE PROPOSAL OR FOR ANY DELAYS IN CONSTRUCTION DUE TO THE ENCOUNTERING OF
EXISTING UTILITIES THAT MAY OR MAY NOT BE SHOWN ON THE PLANS.
9. ANY QUANTITIES AND DIMENSIONS SHOWN ON THE PLANS ARE PROVIDED FOR INFORMATION ONLY, CONTRACTOR SHALL FIELD VERIFY PRIOR TO CONSTRUCTION.
EARTHWORK GRADING & RESTORATION
1. THE CONTRACTOR SHALL RESTORE ALL ADJACENT AREAS UPON COMPLETION OF THE PROJECT.
2. ALL DISTURBED AREAS SHALL BE BROUGHT TO FINAL GRADE AND STABILIZED AS SOON AS POSSIBLE
AFTER BEING DISTURBED. PERMANENT SOIL EROSION AND SEDIMENTATION CONTROL MEASURES SHALL
BE INSTALLED WITHIN FIVE CALENDAR DAYS OF COMPLETING FINAL GRADING.
3. ALL FILL SHALL BE CLEAN SATISFACTORY MATERIAL AS IDENTIFIED IN THE SPECIFICATIONS.
4. SURPLUS EXCAVATED MATERIAL MAY BE USED TO FLATTEN FILL SLOPES AS DIRECTED BY THE ENGINEER.
ANY SURPLUS OR UNSUITABLE MATERIAL, INCLUDING PEAT EXCAVATION, UNABLE TO BE USED SHALL
BECOME THE PROPERTY OF THE CONTRACTOR FOR DISPOSAL.
5. PROTECT AREAS ADJACENT TO MATERIAL STOCKPILES WITH SILT FENCE AS REQUIRED.
6. CONTRACTOR SHALL PLACE TOPSOIL AND SOD ON ALL DISTURBED AREAS NOT UNDER PAVEMENT OR
OTHERWISE LABELED.
7. PROVIDE SCREENED, WEED FREE TOPSOIL FOR RESTORATION.
CONCRETE CONSTRUCTION
1. CONCRETE USED FOR CURB AND SIDEWALK SHALL MEET THE REQUIREMENTS OF SECTION 601 OF THE 2012
MDOT STANDARD SPECIFICATIONS FOR CONSTRUCTION.
2. CONCRETE SIDEWALKS SHALL BE CONSTRUCTED ACCORDING TO MDOT STANDARD DETAIL R-29 SERIES.
3. EXPANSION JOINTS WITH EXPANSION FILLER SHALL BE PLACED WHERE THE CONCRETE PAVEMENT ABUTS AN
EXISTING PAVED SURFACE OR BUILDING OR AS DIRECTED BY THE ENGINEER.
4. PROPOSED SIDEWALK CUT JOINTS SHALL BE CONSTRUCTED TO DIVIDE THE SIDEWALK INTO APPROXIMATELY
25 SQUARE FOOT AREAS OR AS DIRECTED BY THE ENGINEER.
5. ALL SIDEWALKS AND BARRIER FREE RAMPS SHALL BE CONSTRUCTED WITH A MAXIMUM 1:48 CROSS-SLOPE
AND A MAXIMUM 1:12 LONGITUDINAL SLOPE.
6. ALL SIDEWALKS EXCEEDING THE MAXIMUM LONGITUDINAL SLOPE SHALL BE PROVIDED WITH HAND RAILS ON
BOTH SIDES AS DIRECTED BY THE ENGINEER.
P
L
U
R
I B
U
E
S
U
N
U
M
C
I
R
C
U M
S
P
I
C
E
S
I
Q
U
E R
E
I S
P E
N I
N S
U L
A M
A M
O
E
N
A
M
H an co ck
S tre et
H an co ck
, M I 4 p (9
) 4
-0 f
(9
) 4
-6
Ar ch ite ct s.
E ng in ee rs
. P la nn er s.
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N C-
AD
A
EG
RE
SS
R
AM
PS
C O
NS
TR
UC
TI
O N
DE
PA
RT
M
EN
T
O F
CO
RR
EC
TI
O
NS
BA
RA
G A
CI
VI
L
NO
TE
S
LE
G
EN
D
INLET FILTER
UNDERDRAIN
CONCRETE
GRAVEL
SOD
ROUND CATCH BASIN
DTMB: SOIL EROSION AND SEDIMENTATION CONTROL
1. ALL WORK SHALL COMPLY WITH THE APPLICABLE SOIL EROSION AND SEDIMENTATION CONTROL (SESC)
RULES AND REGULATIONS (SOIL EROSION AND SEDIMENTATION CONTROL - 1994 PA 451, PART 91, AS
AMENDED, MCL 324.9101 ET SEQ.).
2. ALL EARTH CHANGES OF ONE ACRE OR MORE OR WITHIN 500 FEET OF WATERS OF THE STATE REQUIRE A
SESC PERMIT. IF A SESC PERMIT IS REQUIRED THE PROFESSIONAL SERVICES CONTRACTOR (DESIGN
CONSULTANT) SHALL PREPARE AN SESC PLAN. THE SESC PLAN SHALL ADDRESS BOTH WIND AND WATER
EROSION AND SEDIMENTATION.
3. THE CONTRACTOR SHALL REVIEW THE DESIGN CONSULTANT'S SESC PLAN IN ORDER TO PREPARE AND
ISSUE FOR APPROVAL AN “SESC IMPLEMENTATION PLAN”, WHICH INDICATES THE CONTRACTOR'S
INTENDED IMPLEMENTATION OF THE SESC PLAN FOR THE PROJECT, INCLUDING A SCHEDULE.
4. THE DTMB SESC PROGRAM, UPON APPROVAL OF THE IMPLEMENTATION PLAN, WILL ISSUE THE
CONTRACTOR AN “AUTHORIZATION TO PROCEED WITH EARTH CHANGE”, WHICH IS TO BE POSTED AT THE
JOB SITE. THIS DOCUMENT IS ISSUED IN LIEU OF A PERMIT FROM THE COUNTY OR OTHER LOCAL
ENFORCING AGENCY.
5. THE CONTRACTOR SHALL IMPLEMENT SOIL EROSION AND SEDIMENTATION CONTROL MEASURES AS
REQUIRED BY THE PROJECT'S SESC PLAN, SESC IMPLEMENTATION PLAN, DTMB'S SOIL EROSION AND
SEDIMENTATION CONTROL GUIDEBOOK, DATED FEBRUARY 2005, AND AS
DIRECTED BY THE PROFESSIONAL SERVICES CONTRACTOR, DTMB SESC INSPECTOR, AND/OR DTMB
PROJECT DIRECTOR. THE DTMB SESC INSPECTOR SHALL INSPECT THE SITE WEEKLY AND AFTER
SIGNIFICANT RAIN EVENTS.
6. THE CONTRACTOR SHALL INSTALL TEMPORARY EROSION AND SEDIMENTATION CONTROL MEASURES
PRIOR TO OR UPON COMMENCEMENT TO EARTHWORK ACTIVITIES.
7. THE CONTRACTOR WILL PERFORM SWEEPING AS NEEDED TO REMOVE ANY SEDIMENT TRACKED OFF SITE.
FREQUENCY OF SWEEPING WILL BE BASED ON SITE CONDITIONS.
8. THE CONTRACTOR WILL PERFORM DUST CONTROL AS NEEDED BASED ON SITE CONDITIONS.
9. DISTURBED AREAS THAT WILL REMAIN IDLE DURING CONSTRUCTION MUST BE TEMPORARILY STABILIZED, INCLUDING SOIL STOCKPILES, USING DTMB SESC BEST MANAGEMENT PRACTICES.
10. THE CONTRACTOR SHALL MAINTAIN AND INSPECT SESC MEASURES THROUGHOUT THE COURSE OF THE
PROJECT. RECOMMEND INSPECTING AND MAINTAINING EROSION AND SEDIMENTATION CONTROLS ON A
DAILY BASIS. AT A MINIMUM, THE CONTRACTOR SHALL INSPECT AND MAINTAIN SESC MEASURES ONCE A
WEEK AND AFTER RAIN EVENTS.
11. THE CONTRACTOR SHALL CORRECT NON-CONFORMING SESC MEASURES WITHIN 24 HOURS, IF WATERS OF
THE STATE ARE BEING IMPACTED OR WITHIN 48 HOURS FOR ROUTINE MAINTENANCE ITEMS. OTHER SESC
MAINTENANCE SHALL BE COMPLETED AS SOON AS POSSIBLE BUT NEVER MORE THAN FIVE (5) DAYS AFTER
DETECTION.
12. THE CONTRACTOR SHALL COMPLETE PERMANENT SOIL EROSION CONTROL MEASURES FOR ANY
DISTURBED LAND AREA WITHIN 5 CALENDAR DAYS AFTER FINAL GRADING OR THE FINAL EARTH CHANGE
HAS BEEN COMPLETED. THE CONTRACTOR SHALL MAINTAIN TEMPORARY CONTROL MEASURES UNTIL
PERMANENT SOIL EROSION CONTROL MEASURES ARE IN PLACE AND THE AREA IS STABILIZED.
13. THE CONTRACTOR SHALL REMOVE TEMPORARY EROSION CONTROL MEASURES AFTER PERMANENT SOIL
EROSION MEASURES ARE IN PLACE AND THE AREA IS STABILIZED. CARE SHALL BE TAKEN DURING REMOVAL
TO PREVENT SOIL EROSION AND SEDIMENTATION.
14. AFTER THE COMPLETION OF THE PROJECT, PERMANENT SESC MEASURES WILL BE MAINTAINED BY THE
PROPERTY OWNER.
http://www.ohm-eng.com
Know what's below.
before you dig.Call
R
UNIT 5 EXISTING SITE PLAN1
P
L
U
R
I B
U
E
S
U
N
U
M
C
I
R
C
U M
S
P
I
C
E
S
I
Q
U
E R
E
I S
P E
N I
N S
U L
A M
A M
O
E
N
A
M
H an co ck
S tre et
H an co ck
, M I 4 p (9
) 4
-0 f
(9
) 4
-6
Ar ch ite ct s.
E ng in ee rs
. P la nn er s.
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N C-
AD
A
EG
RE
SS
R
AM
PS
C O
NS
TR
UC
TI
O N
DE
PA
RT
M
EN
T
O F
CO
RR
EC
TI
O
NS
BA
RA
G A
UN
IT
R
EM
O
VA
L
PL
AN
180 SYD REM CONC
REMOVE TO NEAREST CONTROL JOINT
147 SYD EARTH DISTURBANCE
180 SYD EARTH DISTURBANCE
247 SYD EARTH DISTURBANCE
18 FT REM, FENCE
86'
54'
61'
NOTE: CONTRACTOR SHALL PROVIDE BARRIER
FENCE AROUND ALL EXCAVATIONS
INLET FILTER, TYP
feetGRAPHIC SCALE: FULL feetHALF http://www.ohm-eng.com
Know what's below.
before you dig.Call
R
UNIT 6 EXISTING SITE PLAN1
P
L
U
R
I B
U
E
S
U
N
U
M
C
I
R
C
U M
S
P
I
C
E
S
I
Q
U
E R
E
I S
P E
N I
N S
U L
A M
A M
O
E
N
A
M
H an co ck
S tre et
H an co ck
, M I 4 p (9
) 4
-0 f
(9
) 4
-6
Ar ch ite ct s.
E ng in ee rs
. P la nn er s.
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N C-
AD
A
EG
RE
SS
R
AM
PS
C O
NS
TR
UC
TI
O N
DE
PA
RT
M
EN
T
O F
CO
RR
EC
TI
O
NS
BA
RA
G A
UN
IT
R
EM
O
VA
L
PL
AN
531 SYD EARTH DISTURBANCE
18 FT REM FENCE
PROTECT EX LIGHT POLE
UNDERGROUND UTILITY
CAUTION - CRITICAL
INLET FILTER, TYP
feetGRAPHIC SCALE: FULL feetHALF http://www.ohm-eng.com
R
C
P
A
P
V
C
725.14
MATCH EX
725.13
MATCH EX
724.62
MATCH EX
723.54
MATCH EX
724.89
723.92
724.99
724.42
722.64 INV
722.32 INV
N: 725255.56
E: 25868009.39
N: 725275.88
E: 25868015.76
N: 725242.41
E: 25867980.06
N: 725230.36
E: 25867982.89
N: 725356.23
E: 25867920.87
N: 725344.18
E: 25867920.28
N: 725334.08
E: 25867918.09
N: 725344.36
E: 25867845.25
N: 725335.36
E: 25867845.10
N: 725346.02
E: 25867834.54
N: 725357.94
E: 25867834.84
N: 725245.36
E: 25867983.14
N: 725257.46
E: 25867980.32
N: 725268.90
E: 25868002.43
N: 725262.02
E: 25868000.10
N: 725233.65
E: 25868014.91
N: 725233.36
E: 25867992.61
N: 725244.80
E: 25867988.42
N: 725231.52
E: 25868021.86
ROUND CB-COVER 1040M3
1040-1ZPT ASSEMBLY, ADA
COMPLIANT AND CENTER
BOLTING
T/CAST 722.00
12" RCP INV NE 717.33
A
2'-0"
1/2" MOTAR BED
4"
4'-0"
3"
2" MAX
8" BRICK, 6" CONC BLOCK OR
CONC.
DIA. AS SPECIFIED
INVERT ELEVATION AND DIAMETER AS
SPECIFIED ON THE PLANS
150' MAXIMUM NOTE: DISTANCE TO NEAREST
4' DIA. STRUCTURE
MIN 6" AGGREGATE BASE
PRECAST 3500 P.S.I. CONC. BASE WITH 6
GA. 4"x4" MESH.-MIN.
2000 PSI
CONC.
1040M3 1040-1ZPT ASSEMBLY,
ADA COMPLIANT AND
TAMPER PROOF BOLTED
M I N
M A
X
PLASTER COAT ENTIRE
STRUCTURE, BRICK OR BLOCK
WITH
" CEMENT MORTAR.
Know what's below.
before you dig.Call
R
PROPOSED UNIT 5 EGRESS RAMP1
P
L
U
R
I B
U
E
S
U
N
U
M
C
I
R
C
U M
S
P
I
C
E
S
I
Q
U
E R
E
I S
P E
N I
N S
U L
A M
A M
O
E
N
A
M
H an co ck
S tre et
H an co ck
, M I 4 p (9
) 4
-0 f
(9
) 4
-6
Ar ch ite ct s.
E ng in ee rs
. P la nn er s.
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N C-
AD
A
EG
RE
SS
R
AM
PS
C O
NS
TR
UC
TI
O N
DE
PA
RT
M
EN
T
O F
CO
RR
EC
TI
O
NS
BA
RA
G A
UN
IT
P
RO
PO
SE
D
SI
TE
P
LA
N
RESTORATION AS NEEDED TO INSTALL NEW STORM LINE
APPROXIMATELY 147 SYD
RESTORATION AS NEEDED TO REPLACE WALK
APPROXIMATELY 19 SYD
REPLACE CONC WALK AS NEEDED TO INSTALL RAMP AND NEW STORM LINE
APPROXIMATELY 163 SYD
RESTORATION AS NEEDED TO INSTALL RAMP
APPROXIMATELY 18 SYD
RESTORATION AS NEEDED TO INSTALL RAMP
APPROXIMATELY 71 SYD
REPLACE GATE, SEE ARCH PLANS FOR DETAILS
S
Y
D
O
N
W
A
L
K
RESTORATION AS NEEDED TO INSTALL CULVERT
AND CONC WALK APPROXIMATELY 71 SYD
RESTORATION AS NEEDED TO INSTALL CULVERT AND CONC WALK
APPROXIMATELY 63 SYD
5 SYD, GRAVEL
5 SYD GRAVEL
SEE ARCH PLANS FOR DIMENSIONS
AND GRADING FOR RAMP
R
R
STANDARD INLET DETAIL2
32 FT, 8" PVC CULVERT WITH GRATED END SECTION (OR RODENT GUARD)
ATTACH WITH TAMPER PROOF FASTENERS.
PROPOSED CATCH BASIN,
SEE DETAIL 2 ON THIS SHEET
12" RCP INV WSW 716.11
CONTRACTOR TO VERIFY
EX. 6" PVC STORM IS FOR
BUILDING DRAIN TILE
CONNECT REROUTED
DRAIN TILE TO EXISTING
CONNECT TO EXISTING
86' feetGRAPHIC SCALE: FULL feetHALF
R
R http://www.ohm-eng.com
N: 724827.63
E: 25868250.29
N: 724828.33
E: 25868251.01
N: 724820.68
E: 25868243.10
N: 724816.09
E: 25868261.04
N: 724816.63
E: 25868261.88
N: 724798.37
E: 25868243.01
N: 724797.76
E: 25868259.66
N: 724780.89
E: 25868242.19
N: 724781.26
E: 25868220.98
N: 724798.23
E: 25868221.27
N: 724806.11
E: 25868213.67
N: 724797.95
E: 25868204.92
N: 724808.97
E: 25868194.47
N: 724817.14
E: 25868203.12
718.23
718.49
718.86
719.11
718.89
719.29
719.12
719.55
718.07
718.07
718.23
N: 724808.56
E: 25868232.16
N: 724809.53
E: 25868233.00
N: 724808.56
E: 25868249.26
N: 724791.64
E: 25868231.82
Know what's below.
before you dig.Call
R
PROPOSED UNIT 6 EGRESS RAMP1
P
L
U
R
I B
U
E
S
U
N
U
M
C
I
R
C
U M
S
P
I
C
E
S
I
Q
U
E R
E
I S
P E
N I
N S
U L
A M
A M
O
E
N
A
M
H an co ck
S tre et
H an co ck
, M I 4 p (9
) 4
-0 f
(9
) 4
-6
Ar ch ite ct s.
E ng in ee rs
. P la nn er s.
D
EP
A
RT
M
EN
T O
F
TE
CH
N
O
LO
G Y
, M A
N A
G
EM
EN
T
A N
D B
U D
G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
ST
A
TE
F
A
CI
LI
TI
ES
A
D M
IN
IS
TR
A
TI
O
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N C-
AD
A
EG
RE
SS
R
AM
PS
C O
NS
TR
UC
TI
O N
DE
PA
RT
M
EN
T
O F
CO
RR
EC
TI
O
NS
BA
RA
G A
UN
IT
P
RO
PO
SE
D
SI
TE
P
LA
N
RESTORATION AS NEEDED TO INSTALL WALK &
PROMOTE DRAINAGE TO EXISTING CATCH BASINS
APPROXIMATELY 301 SYD
RESTORATION AS NEEDED TO INSTALL WALK &
PROMOTE DRAINAGE TO EXISTING CATCH BASINS
APPROXIMATELY 73 SYD
147 SYD, CONC WALK
SEE STRUCT PLANS FOR DETAILS
16' CONC CURB, SEE DETAIL 3
ON S-003
5 SYD, GRAVEL
12 SYD, GRAVEL
R
R
INSTALL NEW GATE, SEE ARCH PLANS FOR DETAILS
PROTECT EX LIGHT POLE
R15'
R15' feetGRAPHIC SCALE: FULL feetHALF http://www.ohm-eng.com http://www.ohm-eng.com http://www.ohm-eng.com
| Sheets and Views |
| DT TITLE SHEET |
| C-001 CIVIL NOTES & LEGEND |
| C-120 UNIT 5 REMOVAL PLAN |
| C-121 UNIT 6 REMOVAL PLAN |
| C-130 UNIT 5 PROPOSED SITE PLAN |
| C-131 UNIT 6 PROPOSED SITE PLAN |
| S-001 STRUCTURAL STANDARDS |
| 7136200060-SV_S-001 GEN STRUCTURAL |
| S-002 STRUCTURAL DETAILS |
| 7136200060-SV_SECTIONS & ELEV |
| S-003 STRUCTURAL DETAILS |
| 7136200060-SV_SECTIONS & ELEV |
| S-004 STRUCTURAL DETAILS |
| A-101 HOUSING UNIT 5 RAMP PLAN |
| 7136200060-VA_KEY PLAN |
| 7136200060-AV_FP0_LOWER FLOOR PLAN |
| A-102 HOUSING UNIT 6 RAMP PLAN |
| A-103 DETAILS AND SCHEDULES |
| 7136200060-SV_SECTIONS & ELEV |
| 7136200060-AV_FP0_LOWER FLOOR PLAN |
| E-001 GENERAL ELECTRICAL INFORMATION |
| 7136200060-VE_DETAILS_SCHEDULES |
| E-101 HOUSING UNIT 5 ELECTRICAL PLANS |
| 7136200060-VE_ELEC FP1 PLAN(2) |
| 7136200060-VA_KEY PLAN |
| 7136200060-VE_ELEC FP0 PLAN |
| E-102 HOUSING UNIT 6 ELECTRICAL PLANS |
| 7136200060-VE_ELEC FP1 PLAN(2) |
| 7136200060-VA_KEY PLAN |
| 7136200060-VE_ELEC FP0 PLAN |
| E-301 ELECTRICAL DETAILS |
| 7136200060-VE_DETAILS_SCHEDULES |
| 7136200060-VE_DETAILS_SCHEDULES(2) |
| E-302 ELECTRICAL DETAILS |
| 7136200060-VE_DETAILS_SCHEDULES |
| 7136200060-VE_DETAILS_SCHEDULES(2) |
| E-303 HOUSING UNIT 5 DOOR MONITORING SCHEMATIC |
| 7136200060-VE_DETAILS_SCHEDULES |
| 7136200060-VE_DETAILS_SCHEDULES(2) |
| E-304 HOUSING UNIT 6 DOOR MONITORING SCHEMATIC |
| 7136200060-VE_DETAILS_SCHEDULES |
| 7136200060-VE_DETAILS_SCHEDULES(2) |
| E-401 ELECTRICAL SCHEDULES |
| 7136200060-VE_DETAILS_SCHEDULES |
| 7136200060-VE_DETAILS_SCHEDULES(2) |
| 7136200060-VE_DETAILS_SCHEDULES(3) |
File details come from the government source that posted it. Updated .