Plans.pdf
PDF 4 MB Posted
- Attached to
- 26-14 Sto822305D (Story)
- Solicitation number
- 26-14 Sto822305D (Story)
- Issued by
- Taylor County, Iowa
About this file
This is a Plans document for a wetland construction project in Story County, Iowa, identified as Contract Opportunity 26-14 Sto822305D. The project involves constructing a wetland system designed to treat water from an existing ditch using a solar panel-powered pump. The scope of work includes selective clearing, excavation and grading, installation of tile and outlet structures, pump installation, riprap placement, and seeding across approximately 11.5 acres. The project requires approximately 36,170 cubic yards of earthwork, 1,469 linear feet of pipe installation, 43 tons of riprap, installation of a Modified SW-513 concrete outlet structure, an SW-402 pump basin, and a solar pump system. The construction phase must be completed by September 1, 2027, with seeding work completed by December 15, 2027, following the seeding dates stipulated in the project specifications.
The estimated construction cost range for this project is $240,000 to $360,000. The plans document serves as supporting technical documentation for the bid solicitation and would typically include detailed drawings, specifications, and design parameters necessary for contractors to prepare accurate cost estimates and construction schedules. No specific set-asides, incumbent information, or special funding requirements are indicated in the contract opportunity description.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Schedule of Prices.pdf | ||
| Notice to Bidders.pdf | ||
| Bid Book with plans and specs.pdf | ||
| Standards and Specifications.pdf | ||
| Bid Book - General Requirements only.pdf | ||
| Bid Bond.pdf | ||
| Proposal - Acknowledgement - Affidavit.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
210 210
5T
H A
V E
290TH ST
0T
H A
V E
T AVE
SW
RD
S
T
TH
S T
0T
H A
V E
0T
H A
V E
0T
H A
V E
0T
H A
V E
287TH ST
295TH ST
295TH ST
322ND ST
6T
H A
V E
5T
H A
V E
0T
H A
V E
0T
H A
V E
5T
H A
V E
OAK BLVD
5TH
ST
X AVE
272ND ST
250TH ST
0T
H A
V E
5T
H A
V E
5T
H A
V E
0T
H A
V E
0T
H A
V E
240TH ST
0T
H A
V E
0T
H A
V
E260TH ST
0T
H A
V E
270TH ST
305TH ST
0T
H A
V E
0T
H A
V E
290TH ST
0T
H A
V E
290TH ST
305TH ST
315TH ST
280TH ST
0T
H A
V E
320TH ST
320TH ST51
0T H
A V
E
LINCOLN HWY
TH
S T
260TH ST
270TH ST
0T
H A
V E
220TH ST
LINCOLN HWY
0T
H A
V
E LINCOLN HWY
260TH ST
260TH ST
0T
H A
V E
0T
H A
V E
5T
H A
V E
5T
H A
V E
0T
H A
V E
0T
H A
V E
280TH ST
0T
H A
V E
0T
H A
V E
0T
H A
V E
0T
H A
V E
300TH ST
315TH ST
320TH ST
0T
H A
V E
0T
H A
V E
282ND ST
280TH ST
0T H
A V
E
290TH ST
300TH ST300TH ST
310TH ST 310TH AVE
5T
H A
V E
0T
H A
V E
0T
H A
V E
C O
UN
TR
Y C
LU
B
RD
250TH ST
220TH ST
6T
H A
V E
0T
H A
V E
0T
H A
V E
0T
H A
V E
W MAPLE AVE
SA
N
D H
ILL
T
R
245TH ST
250TH ST
270TH ST
270TH ST
0T
H A
V E
265TH ST
TIM
BE
R
RD
320TH
LN
305TH
LN
4T
H A
V E
T AVE
0T
H A
V E
340TH ST340TH ST340TH ST340TH ST
ZUMWALT
STATION RD
SOUTH
S AVE
280TH
ST
0T
H A
V E
8T
H A
V E
0T
H A
V E
5T
H A
V E
303RD
ST
5T
H
A V
E
220TH ST
0T
H A
V E
306TH LN
2N
D A
V E
ONTARIO ST
2N
D A
V E
310TH ST
335TH ST
RI
V
ER
SI
D E
D R
DARTMOOR RD
C
ED
A R
LN
SO
UT
H D
A
KO
TA
A
V E
275TH
ST
3R
D A
V E
7T
H A
V E
NEVADA
KELLEY
SLATER HUXLEY
CAMBRIDGE
MAXWELL
C re ek
G ra nt
O pen
Ditch
In d ia n
W est
W alnut
S kunk
Cre ekW or le
Creek
R iver
Ea st
Ballard Creek
Coon C reek
Ru pp le
C a la m us
C reek
UNIVERSITY
SHIPLEY
IOWA
CENTER
W A S H I N G T O N
G R A N T
N E V A D A
U N I O N
P A L E S T I N E
131718
19 21 22 23
252627282930
31 32 33 34 35 36
7 8 9 11
131415161718
19 20 21 23 24
252627282930
31 32 33 34 35 36
19 20
282930
31 32
23456
7 8 9 11 12
131415161718
19 20 21 22 24
272829
32 33 34 35 36
23456
7 8 9 11 12
131415
19 20 22 23 24
252627282930
31 33 34 36
7 8
19 20
31 32
STATE
NURSERY
E57
E41
R38
R38 E63
E57
R70
R70
S14
E63
S14
R70
E63
AMES
MUNICIPAL
AIRPORT S
D A
YT
O
N A
V E
S14
I N D I A N
C R E E K
W
RD
S
T
A.01
TITLE SHEET
PROJECT DATUM: STATE PLANE
HORIZONTAL: IOWA NORTH
VERTICAL: NAVD 1988
MY LICENSE RENEWAL DATE IS
PAGES OR SHEETS COVERED BY THIS SEAL:
LICENSE NUMBER: DATE:
I OWA
LI
CE
NS
ED
PROFESS IONAL ENG
INEER
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF IOWA.
29449
12/31/2026
ALL SHEETS
BRANDON C.
SHORT
29449
BRANDON C. SHORT, PE
STORY COUNTY, IA
CONSTRUCTION PLANS FOR
IDALS NO. STO822305D
NUTRIENT REDUCTION WETLAND
STORY COUNTY, IOWA
JANUARY 2026
THE SPECIFICATIONS AS PREPARED BY IOWA DEPARTMENT OF AGRICULTURE
AND LAND STEWARDSHIP AND BOLTON & MENK, INC. SHALL BE CONSIDERED
AS PART OF THIS DOCUMENT. NATURAL RESOURCES CONSERVATION SERVICE
CONSTRUCTION SPECIFICATIONS SHALL APPLY.
THE CURRENT EDITION OF THE "IOWA STATEWIDE URBAN STANDARD
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS" SHALL GOVERN.
IOWA DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATIONS FOR
HIGHWAY AND BRIDGE CONSTRUCTION" AND ALL CURRENT GENERAL
SUPPLEMENTAL SPECIFICATIONS AND MATERIALS INSTRUCTIONAL
MEMORANDUM SHALL GOVERN AS REFERENCED.
ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND ORDINANCES WILL BE
COMPLIED WITH IN THE CONSTRUCTION OF THIS PROJECT.
GOVERNING SPECIFICATIONS
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS
UTILITY QUALITY LEVEL D. THIS UTILITY QUALITY LEVEL WAS
DETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE
38-02, ENTITLED "STANDARD GUIDELINES FOR THE
COLLECTION AND DEPICTION OF EXISTING SUBSURFACE
UTILITY DATA."
THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING IOWA
ONE CALL BY PHONE AT 811, OR ON THE WEB AT
HTTP://WWW.IOWAONECALL.COM/. TICKET# ___________.
TICKET NUMBER MUST BE PROVIDED TO THE NRCS PRIOR TO
COMMENCEMENT OF WORK.
NOTES
1. IF A CULTURAL RESOURCE IS IDENTIFIED DURING
CONSTRUCTION, STOP WORK IMMEDIATELY AND NOTIFY
THE LOCAL NATURAL RESOURCES CONSERVATION SERVICE
OFFICE.
2. THERE IS NO GUARANTEE THAT THE WETLAND WILL FILL OR
REMAIN FILLED WITH WATER.
R-24W
PROJECT
LOCATION
T-
N
CONSERVATION PRACTICE STANDARDS USED:
656 - CONSTRUCTED WETLAND
NRCS JOB CLASS: III
WATERSHED AREA < 300 AC
TO THE BEST OF MY PROFESSIONAL KNOWLEDGE,
JUDGEMENT, AND BELIEF, THESE PLANS MEET APPLICABLE
NRCS STANDARDS AND APPLICABLE LAWS AND
REGULATIONS.
CLIENT ACCEPTANCE
SIGNATURE DATE
R
FEETSCALE
0 1 2
T-
N
R-23W R-22W
T-
N T-
N
R-24W R-23W R-22W
SHEET INDEX
SHEET NO. SHEET TITLE
A.01 TITLE SHEET
A.02 PLAN OVERVIEW SHEET
B.01 RCP INSTALLATION DETAIL
B.02 CPDT INSTALLATION DETAIL
B.03 PUMP BASIN DETAIL
B.04 WETLAND OUTLET STRUCTURE & TRASH GUARD DETAIL
B.05 ANTI-SEEP COLLAR DETAIL
C.01 ESTIMATED QUANTITIES
D.01 GRADING OVERVIEW
D.02 INLET CHANNEL
D.03 NORTHEAST BERM & AUXILIARY SPILLWAY
D.04 SOUTH BERM
D.05 NORTH POOL CROSS SECTION (E-W)
D.06 SOUTH POOL CROSS SECTION (E-W)
D.07 POOL CROSS SECTION (N-S)
K.01 SEEDING PLAN
M.01 PUMP INLET PIPE & WETLAND OUTLET PIPE
M.02 RING TILE
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
A0
1.
dw g 1/
/2
:1
2:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
AMES
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS © 2025 TomTom
BULAND, BETTY B
SMALLEY,
RAYMOND LSTORY COUNTY
STORY COUNTY
LARSON BROTHERS LLC
LARSON, SHANE
LARSON BROTHERS LLC
LARSON, SHANE
BULAND, BETTY B
BULAND, BETTY B
BULAND, BETTY B
BULAND, BETTY B GUSTAFSON,
DELWIN J & CINDY GUSTAFSON, DELWIN J & CINDY
RING TILE
6" HDPE
855 856
855854
CONSTRUCTION ACCESS
FROM 280TH ST
10 FT EMBANKMENT
TOP ELEV. 856.00
10 FT EMBANKMENT
TOP ELEV. 856.00
50 FT INLET CHANNEL
BOTTOM ELEV. 854.00
NWL = 855.00
EXCAVATE TO 854.00
PUMP INLET PIPE
18" RCP
DUPLEX SOLAR-POWERED PUMP
OUTLET STRUCTURE
MODIFIED SW-513
72" x 72"
WETLAND OUTLET PIPE
36" RCP
50 FT AUXILIARY SPILLWAY
CREST ELEV. 855.50
PROPOSED EASEMENT BOUNDARY
100-YEAR HWL = 855.95
FEMA NFHL 1% FLOOD RISK BOUNDARY
ELEV. ≈ 857
FEMA NFHL 0.2% FLOOD RISK BOUNDARY
ELEV. ≈ 858 (SITE IS WITHIN 0.2% FLOOD RISK ZONE)
PROPERTY LINES
SOLAR PANELS
EXCAVATION
SPOIL PILE
EXCAVATION
SPOIL PILE
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
A0
2.
dw g 1/
/2
:1
3:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
A.02
PLAN OVERVIEW SHEET
R
FEETSCALE
0 100 200
HORZ.
DESIGN CRITERIA VALUE UNIT REQUIREMENT
PUMPED WATERSHED AREA 12480 ACRES
PUMP PERCENT CAPTURE 18.3%
EFFECTIVE TREATED WATERSHED 2278 ACRES
SURFACE WATERSHED AREA 174 ACRES
POOL NORMAL WATER LEVEL (NWL) ELEV 855.00 FT
DESIGNED WETLAND POOL AREA (@ NWL) 16.3 ACRES
POOL AREA TO EFFECTIVE WATERSHED AREA RATIO 0.7 % Range 0.5% to 2% of watershed area
MAXIMUM POOL DEPTH 2.5 FT
AVERAGE POOL DEPTH 1.0 FT
DEEP WATER AREA (DEPTH > 3 FT) 0.0 ACRES
PERCENT DEEP WATER TO POOL AREA 0.0 % Less than 25%
POOL STORAGE VOLUME AT NWL 16.7 ACRE-FT
OVERFLOW ELEVATION 855.50 FT
POOL STORAGE VOLUME AT OVERFLOW 25.0 ACRE-FT
PRIMARY WEIR ELEVATION 855.00 FT
PRIMARY WEIR WIDTH 22 FT Four 5.5-foot openings
TOTAL EASEMENT AREA 41.6 ACRES
AREA OF BUFFER 25.3 ACRES
RATIO BUFFER AREA TO NWL POOL AREA 1.6 Less than 4
AVERAGE CAPTURE FLOW 0.5 CFS
25-YEAR STORM HWL IN POOL 855.8 FT
25-YEAR PEAK INFLOW 85 CFS
25-YEAR PEAK OUTFLOW 73 CFS
100-YEAR STORM HWL IN POOL 855.95 FT
100-YEAR PEAK INFLOW 119 CFS
100-YEAR PEAK OUTFLOW 105 CFS
WETLAND ELEV INCREMENTAL CUMULATIVE CUMULATIVE
POOL DEPTH AREA VOLUME VOLUME
(FT) (FT) (FT2
) (FT3
) (AC-FT)
0.0 852.5 10,000
0.5 853.0 26,700 9,175 0.21
1.0 853.5 32,000 23,850 0.55
1.5 854.0 37,700 41,275 0.95
1.5 854.0 664,500 41,275 0.95
2.0 854.5 681,100 377,675 8.67
2.5 855.0 710,200 725,500 16.66
3.0 855.5 746,400 1,089,650 25.01
3.5 856.0 1,122,900 1,556,975 35.74
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
B0
1.
dw g 1/
/2
:1
3:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.01
RCP INSTALLATION DETAIL
TRENCH INSTALLATION TYPE 3
COMPLETELY FILL
HAUNCH AREA WITH
GRAVELLY SAND
COMPACT TO 85%
STANDARD PROCTOR
DENSITY.
Do
LOOSELY PLACED UNCOMPACTED
GRAVELLY SAND BEDDING
Do/3
3" MIN.
PIPE SPRINGLINE
GRAVELLY SAND BEDDING SHALL BE CONSISTENT WITH THE GRADATION AND
OTHER CHARACTERISTICS OF STANDARD AASHTO A1 OR A3 SOIL. A
REPRESENTATIVE SAMPLE OF THE MATERIAL AND A GRADATION REPORT OR
SUPPLIER'S CERTIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE
ENGINEER FOR APPROVAL PRIOR TO DELIVERY TO SITE. SEE SOIL DATA IN
APPENDIX OF SPECIFICATIONS BOOKLET.
6" TYP
0" MIN MEASURE POINT FOR
MAXIMUM TRENCH WIDTH
TOP OF
PIPE
CRUSHED ROCK MEETING THE GRADATION OF SUDAS CLASS I BEDDING
MATERAL, SPECIFICATION SECTION 3010.2.02.A, MAY BE SUBSTITUTED FOR
THE SAND OR CLAY HAUNCH BACKFILL MATERIAL. NO COMPACTION WILL BE
REQUIRED FOR THE CRUSHED ROCK BEDDING AND BACKFILL. MATERIAL
COSTS SHALL BE INCIDENTAL TO PIPE INSTALLATION.
MODIFIED TRENCH INSTALLATION TYPE 4
COMPLETELY FILL HAUNCH
AREA WITH NON-SATURATED
SILTY CLAY OR CLAY SOIL.
COMPACT TO 85% STANDARD
PROCTOR DENSITY. THERE
ARE NO SPECIFIED MOISTURE
LIMITS.
Do
WHERE TRENCH BOTTOM IN FIRM UNDISTURBED SOIL,
SHAPE TRENCH BASE GROOVE TO MATCH MINIMUM
1/6 OF THE OUTER CIRCUMFERENCE OF THE PIPE.
WHERE THE SHAPED GROOVE CANNOT BE
CONSTRUCTED INTO UNDISTURBED GROUND OR
WHERE EXCESS CUT OCCURS OVER EXCAVATE AND
PLACE MINIMUM 3-INCH THICK COMPACTED GRAVELLY
SAND BEDDING TO RESTORE GRADE SUCH THAT 1/6 OR
MORE OF THE OUTER CIRCUMFERENCE OF THE PIPE IS
BEDDED. THIS MATERIAL AND WORK IS SUBSIDIARY TO
THE INSTALLATION OF THE PIPE. CONTRACTOR MAY
SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING
MATERIAL. IT ALSO IS SUBSIDIARY.
PIPE SPRINGLINE
6" TYP
0" MIN MEASURE POINT FOR
MAXIMUM TRENCH WIDTH
TOP OF
PIPE
MINIMUM TRENCH WIDTH SHALL BE OUTSIDE DIAMETER OF PIPE PLUS 12" OR
THAT WIDTH WHICH IS REQUIRED FOR COMPACTION, WHICHEVER IS GREATER
WHERE FIRM BASE IS NOT
ENCOUNTERED. OVER
EXCAVATE AS DIRECTED BY
ENGINEER. PLACE CRADLING
ROCK AND BED PIPE IN IT
SUCH THAT 1/6 OR MORE OF
THE OUTER CIRCUMFERENCE
OF THE PIPE IS SUPPORTED.
THIS ROCK IS PAID FOR UNDER
A SEPARATE BID ITEM.
THE CONTRACTOR IS SOLEY RESPONSIBLE FOR THE INSTALLATION OF ALL PIPE ACCORDING TO PLAN REQUIREMENTS.
THE CONTRACTOR'S PARTICIPATION IN AND COMPLIANCE WITH THE FOLLOWING PROCEDURE IS REQUIRED AND WILL
ALLOW FOR FEWER SOIL DENSITY TESTS TO ENSURE PROPER PIPE INSTALLATION.
STEP 1
BEFORE COMMENCING PIPE INSTALLATION, STANDARD SOIL PROCTOR DENSITY TEST RESULTS OF REPRESENTATIVE SAMPLE(S) OF PIPE HAUNCH FILL SHALL BE PROVIDED BY AN INDEPENDENT QUALIFIED SOILS TESTING LAB. THE SELECTION OF THE SAMPLE(S) WILL BE MADE BY THE ENGINEER AND CONTRACTOR (WHEN SPECIFIED).
STEP 2
CONTRACTOR MAY BEGIN EXCAVATING THE MODIFIED TYPE 4 TRENCH
WITH THE REQUIRED SHAPED BOTTOM GROOVE AND PLACE SEVERAL PIPE SECTIONS ONLY WHEN BOTH ENGINEER AND
TESTING LAB TECHNICIAN ARE PRESENT
CONTRACTOR SHALL DEMONSTRATE THE INTENDED METHODS FOR COMPACTING THE FILL FOR THE PIPE HAUNCH AREAS. SOIL DENSITY TESTS SHALL BE TAKEN AT LOCATIONS DESIGNATED BY THE ENGINEER TO CONFIRM THAT THE INTEDNED METHODS FOR FILL AND COMPACTION OF THE PIPE HAUNCH AREAS SATIFIES THE PLAN REQUIREMENTS.
CONTRACTOR SHALL MODIFIY THE INSTALLATION METHODS AND REPEAT STEP 2 UNTIL ACCEPTABLE TESTS RESULTS ARE
ACHIEVED.
STEP 3
CONTRACTOR MAY INSTALL THE NEXT SEVERAL HUNDRED FEET OF PIPE. ENGINEER SHALL DESIGNATE SEVERAL LOCATIONS (APPROXIMATELY 10% OF THE INSTALLED LENGTH) WHERE CONTRACTOR SHALL LEAVE THE PIPE UNBLINDED FOR FURTHER DENSITY TESTS OF THE HAUNCH FILL AREA. ALL DENSITY TESTS MUST MEET PLAN REQUIREMENTS BEFORE
WORK MAY PROCEED FURTHER.
IF DENSITY TESTING DATA CONFIRMS TO THE SATISFACTION OF THE ENGINEER THAT THE CONTRACTOR'S INSTALLATION METHOD WILL PRODUCE CONSISTENT COMPLIANCE WITH PLAN REQUIREMENTS, CONTRACTOR MAY CONTINUE INSTALLATION OF THE PIPE WITH NO ADDITIONAL TESTING REQUIRED. IF NOT, STEPS 2 AND 3 SHALL BE REPEATED UNTIL A RELIABLE, SUCCESSFUL METHOD OF PIPE INSTALLATION THAT PRODUCES SATISFACTORY RESULTS IS ESTABLISHED.
TRENCH WALLS
PLUG DOWNSTREAM
TILE WITH PLASTIC END
PLUG, CONCRETE, OR
AS OTHERWISE
ALLOWED.FLOW FLOW
CUT AND SHAPE END OF P.E.
TILE TO FIT FLUSH WITH INSIDE
OF CONCRETE TILE. GROUT
CONNECTION
FILL TRENCH TO P.E. SPRINGLINE WITH COMPACTED CRUSHED
STONE. WHERE COVER EXCEEDS 8 FEET, COVER CONNECTION
AND EXPOSED P.E. WITH 12 INCHES OF CRUSHED STONE
BEDDING COMPLYING WITH SUDAS SPECIFICATION SECTION
3010.301. BUCKET PRESS & COMPACT EARTH FILL UNIFORMLY
ON BOTH SIDES OF STONE TO RESIST LATERAL MOVEMENT OF
THE STONE.
CONCRETE COLLAR EXCEPTION
CONNECTIONS TO THE PIPE AT BOTH ENDS MAY BE MADE
WITH A MANUFACTURED POLYETHYLENE INTERNAL SNAP
COUPLER INSERTED FULLY INTO THE PIPE. CONCRETE COLLARS
NOT REQUIRED WITH POSITIVE LOCKED CONNECTION OR
WHERE COMPACTED CRUSHED ROCK FULLY SURROUNDS THE
CONNECTION. GAPS AT THE CONNECTIONS SHALL BE COVERED
WITH ENGINEERING FABRIC WRAPPED AROUND THE JOINT.
INSERTA TEE WILL BE CONSIDERED AS ALTERNATE
CONNECTION AT NEW MAIN WITH ENGINEERS PRIOR
APPROVAL AND INSTALLATION PER MANUFACTURERS
RECOMMENDATION.
TYPICAL FIELD TILE CONNECTION
FOR FIELD TILE UP TO 10" DIAMETER
CO
VE
R
USE NON-PERFORATED
CORRUGATED P.E. DRAIN TILE
UNDISTURBED
SOIL
SLIDE CORRUGATED P.E. TILE A
MINIMUM OF 6" OVER END OF
EXISTING TILE. ENCASE JOINT (IF
NOT TIGHT FITTING) IN P.C.
CONCRETE COLLAR, AS SHOWN.
FIELD TILE
A
A
PIPE HAUNCH FILL AND COMPACTION METHOD
PLAN REQUIREMENTS COMPLIANCE VERIFICATION
12"
6"
HAND SHAPE TRENCH FOR P.E.
TILE TO INSURE UNDISTURBED
SOIL SUPPORT LOWER 1/2 OF
TILE PERIMETER OR BED ON
CRUSHED STONE FILL AND
THOROUGHLY TAMP SOIL
ENVELOPE
SECTION A-A
TOP OF SOIL
ENVELOPE
UNDISTURBED
SOIL
CONTRACTOR IS REQUIRED TO PROPERLY AND ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE
INSTALLATION WORKERS ON THE PROPER INSTALLATION METHOD.
STEP 4A
SOIL OR TRENCH CONDITION CHANGES
TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS UNDER THE CHANGED CONDITIONS, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH
3. THE WORK AND COSTS OF THE FIRST TWO REVERIFICATIONS IS SUBSIDIARY TO THE PIPE INSTALLATION. SUBSEQUENT
VERIFICATIONS WILL BE CONSIDERED EXTRA WORK.
STEP 4B
CONTRACTOR FAILS TO CONSISTENTLY PERFORM INSTALLATION METHOD OR INSTRUCT OTHER INSTALLERS
IF CONTRACTOR FAILS TO CONSISTENTLY PERFORM OR ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE INSTALLATION WORKERS ON THE APPROVED INSTALLATION METHOD, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH 3 TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS. THE WORK AND COSTS OF ALL VERIFICATIONS UNDER SUCH
CONDITIONS IS SUBSIDIARY TO THE PIPE INSTALLATION.
EXCEPTION
IF CONTRACTOR ELECTS TO SHAPE THE TRENCH BOTTOM SUCH THAT A MINIMUM OF 45% OF THE OUTER CIRCUMFERENCE OF THE PIPE IS FIRMLY BEDDED IN AND CONSISTENTLY SUPPORTED BY UNDISTURBED SOIL, PIPE HAUNCH FILL COMPACTION TESTING WILL NOT BE REQUIRED. THE CONTRACTOR IS REQUIRED TO COMPLY WITH A PROPER INSTALLATION METHOD AND TO FULLY COMPLY WITH THE REQUIREMENTS OF THE VERIFICATION OUTLINED
ABOVE FOR ALL SITUATIONS WHERE THIS EXCEPTION IS NOT MET.
NOT TO SCALE
SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION
CONCRETE PIPE DESIGN MANUAL
NOT TO SCALE
SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION
CONCRETE PIPE DESIGN MANUAL
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
B0
1.
dw g 1/
/2
:1
3:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.02
CPDT INSTALLATION DETAIL
FLAT BOTTOM TRENCH INSTALLATION
FILL TRENCH TO 6" ABOVE TOP OF PIPE WITH CRUSHED STONE OR GRAVEL
MEETING THE REQUIREMENTS IN TABLE 2. BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE PIPE INSTALLATION.
PREFFERED TRENCH INSTALLATION BOTTOM
CORRUGATED POLYETHYLENE DRAINAGE TUBING
MATERIAL & INSTALLATION NOTES
NOT TO SCALE
SOURCE: ASTM F449
TRAPEZOIDAL GROOVE, "V" GROOVE, & CIRCULAR GROOVE
NOT TO SCALE
SOURCE: ASTM F449
6" MIN FOR
OPEN TRENCH
INSTALLATION
R
6" M
IN
A B G
0.
5R
0.
R
TRENCH WIDTH MEASURED
AT TOP OF PIPE
90° "V" GROOVE
90°
THE CIRCULAR GROOVE SHALL BE A
MINIMUM 0.35R DEEP AND SHALL
MATCH THE OUTSIDE CURVE
SHAPE OF THE DEFLECTED CPDT.
THE TRAPEZOIDAL GROOVE SHALL
BE SHAPED AND ADJUSTED SUCH
THAT POINTS A, B, & C WILL TOUCH
THE UNDEFLECTED CPDT FOR EACH
SIZE INSTALLED.
TRAPEZOIDAL GROOVE
CIRCULAR GROOVE
UNDISTURBED SOIL
UNDISTURBED SOIL
TRENCH WIDTH MEASURED
AT TOP OF PIPE
4" M
IN
SEE TABLE 2 FOR
BEDDING MATERIAL
NOTE: THIS IS AN ALLOWED ALTERNATIVE INSTALLATION FOR CPDT
1. ALL CPDT AND CONNECTORS FURNISHED SHALL BE IN COMPLIANCE WITH MATERIAL STANDARDS ASTM F405 AND F667, AS
APPLICABLE, AND SHALL BE CLASSIFIED AS HEAVY-DUTY UNDER THOSE STANDARDS.
2. EXCEPT MODIFIED HEREIN OR OTHERWISE APPROVED BY ENGINEER, ALL CPDT SHALL BE INSTALLED IN COMPLIANCE WITH THE
ASTM 449 STANDARD PRACTICE.
3. FOR PIPES 6” DIAMETER AND SMALLER A 90° V GROOVE BOTTOM MAY BE USED, FOR ALL LARGER PIPE A TRAPEZOIDAL BOTTOM OR A CIRCULAR BOTTOM CONFORMING TO THE OUTSIDE DIAMETER OF THE PIPE SHALL BE USED. PRIOR TO THE INSTALLATION OF CPDT, CONTRACTOR MUST PROVE TO ENGINEER THAT THE INSTALLATION REQUIREMENTS, INCLUDING THE
SHAPE OF THE TRENCH BOTTOM, WILL BE ACCOMPLISHED.
4. WHERE TRENCH BOTTOM IS IN FIRM UNDISTURBED SOIL, SHAPE TRENCH BASE GROOVE. WHERE EXCESS CUT OCCURS, OVEREXCAVATE AND PLACE MINIMUM THREE (3) INCH THICK, GRAVELLY SAND BEDDING TO RESTORE GRADE. THIS BEDDING SHALL MEET THAT REQUIRED FOR TRENCH INSTALLATION TYPE 3 ON PLAN SHEET B.02. THIS MATERIAL AND WORK SHALL BE INCIDENTAL TO THE INSTALLATION OF THE PIPE. CONTRACTOR MAY SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING
MATERIAL.
5. NATIVE SOILS MAY BE USED AS BACKFILL MATERIAL UNLESS UNSTABLE TRENCH CONDITIONS PREVENT THE TRENCH BOTTOM HOLDING THE SHAPED GROOVE. IF TRENCH BOTTOM WILL NOT HOLD GROOVE SHAPE CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY. A FLAT BOTTOM TRENCH INSTALLATION WILL THEN BE ASSUMED. THE REQUIRED BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE INSTALLATION OF THE PIPE.
6. MINIMUM TRENCH WIDTH IS PIPE OUTSIDE DIAMETER PLUS FOUR (4) INCHES FOR PLOWED INSTALLATION AND PIPE OUTSIDE
DIAMETER PLUS TWELVE (12) INCHES FOR OPEN TRENCH INSTALLATION.
7. ALL LATERAL CONNECTIONS, ELBOWS, TEES, ALIGNMENT CURVES, START HOLES AND ALL PORTIONS OF THE TRENCH NOT MEETING THE GROOVED TRENCH INSTALLATION REQUIREMENTS SHALL BE FILLED TO A MINIMUM OF SIX (6) INCH COVER OVER THE PIPE WITH GRADED CRUSHED STONE OR GRAVEL AS SHOWN ON TABLE 2 OF THIS SHEET. BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE INSTALLATION OF THE PIPE.
8. MANUFACTURER'S ENDCAPS SHALL BE INSTALLED AT THE TERMINATION OF EACH LINE UNLESS A CONNECTION TO AN EXISTING
DRAIN IS MADE.
9. WITH THE INSTALLATION OF THE FIRST REACH OF CPDT ON THE PROJECT, CONTRACTOR IS REQUIRED TO WORK WITH THE
ENGINEER TO CHECK AND CONFIRM THAT THE PIPE STRETCH, IF ANY, DOES NOT EXCEED 5%.
10. ALIGNMENT TURNS MAYBE MADE USING EITHER A MANUFACTURED FITTING OR CURVING THE LINE WITH A 25' MINIMUM
RADIUS.
R25'
PI
X °
PT
PT
Table 1 Maximum Allowable Buried Depth to Flowline of CPDT
Nominal Pipe Diameter (IN)
Pipe Quality
(ASTM)
Trench Width at Top of the Pipe (FT)
12" 18" 24" 30" or Greater
Standard 13 7 5.5 5
Heavy-duty Any 10 7 6
Standard 10 7 5.5 5
Heavy-duty Any 9.5 6.5 6
Standard 10 7 5.5 5
Heavy-duty Any 10 7 6
10 Heavy-duty ... 9 7 6 12 Heavy-duty ... 9 7 6 15 Heavy-duty ... ... 7 6
Table 2 Acceptable Bedding Material and Compaction Requirements
Description Percentage Passing Sieve Sizes Minimum
Standard Density (%)
Maximum Compaction Layer Height
(IN.)1" 3/4" No. 4
Crushed Stone Crushed Gravel* 100% > 95% < 5% Dumped 18
* Class 1 Bedding Material Per SUDAS 3010.202A is an Allowable Substitute
DEGREES Δ DELTA
20° 4.41 30° 6.7 45° 10.36 60° 14.43 70° 17.51 80° 20.98 90° 25 ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
B0
1.
dw g 1/
/2
:1
3:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.03
PUMP BASIN DETAIL
SOLAR
NOTE: SOLAR PANELS SHALL BE INSTALLED IN THE LOCATION SHOWN ON
A.02 AND M.01 WITH A SOUTHWARD ORIENTATION.
SOLAR POWERED PUMP SYSTEM (BID ITEM 16) SHALL INCLUDE THE FOLLOWING:
· SOLAR PANELS
· SOLAR DRIVE
· 3-PHASE, 3 HP AXIAL PUMP (CARRY CP-04 WITH 17° IMPELLER OR
APPROVED EQUAL, PROVIDING 350 GPM AT 10.5 FT TDH)
· FLOAT SWITCH
· MOUNTING CLAMPS FOR CONTROLLER
· SOLAR PANEL MOUNTING KIT
· STEEL PIPE EXTENDERS
· WIRED GENERATOR PLUG
· LIGHTNING & SURGE PROTECTOR
· WIRING FOR PANELS, PUMP, AND CONTROLLER
CONTRACTOR SHALL PROVIDE THE FOLLOWING, SUBSIDIARY TO BID ITEM XX:
· STEEL PIPE FOR MOUNTING
· CONCRETE AND ROCK BEDDING FOR MOUNTING POLES
· PVC DISCHARGE PIPE
· CHECK VALVE
PUMP BASIN (BID ITEM XX) SHALL INCLUDE THE FOLLOWING:
· PUMP BASIN (MODIFIED SW-401, SEE DETAILS)
· STEEL LID WITH STAND
MOUNT PUMP CONTROLLER TO
SOLAR POSTS
INSTALL SOLAR DRIVES NEXT TO PUMPS
ON POSTS ABOVE ELEV. 862.00
FILL HOLE WITH CONCRETE
MIN. 12" DIAMETER
FLOW
EXTERIOR MASTIC &
FABRIC WRAP
ALL JOINTS - 9" WIDE
4'
14'
MIN. 12"
18" RCP
FL EL = 847.10
PAINTED STEEL LID WITH ACCESS HATCH
TOP EL = 860.00
8" PVC PUMP OUTLET
EL = 857.00
EXISTING GROUND
APPROX. EL = 857.00
NORMAL POOL = 855.00
EXCAVATED POOL
8" MIN. CLASS I BEDDING MATERIAL
SUMP = 840.00
SUDAS SW-402 STRUCTURE
2 FT
PLACE RIP RAP
SEE M.01
INSTALL PUMP CONTROL PANELS
ADJACENT TO PUMP BASIN OR ON
EMBANKMENT. MOUNT ON
POSTS ABOVE ELEVATION 862.00.
INSTALL CHECK VALVE
FLEXIBLE WATERTIGHT SEALS
4'
17'
18" RCP
FL EL = 847.10
PAINTED STEEL LID WITH ACCESS HATCH
TOP EL = 860.00
8" PVC PUMP OUTLET
EL = 857.00
8" MIN. CLASS I BEDDING MATERIAL
SUMP = 840.00
SUDAS SW-402 STRUCTURE
FLEXIBLE WATERTIGHT SEALS
FLOAT ELEVATIONS
PUMP 1 PUMP 2
ON 846.60 847.10
OFF 842.50 843.00
NORTH
20 FT
4" SCHEDULE 40 STEEL PIPE REQUIRED: 4 x 21' *CUT TWO IN HALF TO MAKE 4 x 10.5' IN GROUND POST
PUMP CONTROLLER AND SOLAR PANELS SHALL BE
ENTIRELY ABOVE THE ELEVATION 862.00.
PIPE INCLUDED IN KIT
GROUND SURFACE
20 FT
4.5 TO 5 FT
3 TO 3.5 FT
3.5 FT 21 FT
INSTALL SOLAR ARRAYS IN TWO ROWS
OF 7 PANELS. ARRAYS SHALL HAVE A
SOUTHWARD ORIENTATION AND BE
SPACED 20 FT APART.
DPC2500
SOLAR DRIVE
SOLAR
DISCONNECT
PUMP WIRING DIAGRAM
NOT TO SCALE
SW-402 WEIR & PUMP BASIN ELEVATION
NOT TO SCALE
XXX FT
SW-402 WEIR & PUMP BASIN ELEVATION
NOT TO SCALE
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
B0
1.
dw g 1/
/2
:1
3:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.04
WETLAND OUTLET STRUCTURE DETAIL
TOP OF STRUCTURE ELEVATION (SEE PROFILE)
A B.01
A
6" SUMP
FL ELEV (SEE PROFILE)
PRECAST OPENING ELEVATION
PROVIDE FLEXIBLE, WATERTIGHT GASKET FOR PIPE OPENINGS
SEE SUDAS FOR SW-513 DETAILS
PRECAST STRUCTURE SHALL BE ONE SECTION OR
PROVIDE WATERTIGHT SEAL BETWEEN SECTIONS.
72" WALL
WIDTH
72" WALL WIDTH
1.25'
SEE SUDAS FOR SW-513 DETAILS
OUTLET PIPE
BEDDING PER SUDAS72" WALL WIDTH
2 LF 12" DUAL-WALL HDPE
12" HICKENBOTTOM INTAKE
OR APPROVED EQUAL
2 LF 12" DUAL-WALL HDPE
12" HICKENBOTTOM INTAKE OR APPROVED EQUAL
12" 90° ELBOW
EXCAVATED WETLAND POOL
EXCAVATE 1 FT ADDITIONAL AROUND INTAKE
PLACE RIP RAP IN 3-FT DIA. CIRCLE AROUND INTAKE
UNDERLAY WITH GEOTEXTILE (1.5 TN)
PLACE RIP RAP IN 6-FT DIA. CIRCLE AROUND INTAKE
UNDERLAY WITH GEOTEXTILE (1.5 TN)
AGRI DRAIN IN-LINE
WATER LEVEL CONTROL
STRUCTURE OR
APPROVED EQUAL
ATTACH TO CONCRETE
STRUCTURE
AGRI DRAIN IN-LINE WATER LEVEL CONTROL
STRUCTURE OR APPROVED EQUAL
STUB IN 12" PIPE
BACKFILL MIN. 1 FT AROUND
WCS WITH 1" CLEAN ROCK
NORMAL WATER LEVEL
9" INLET OPENING
ON ALL SIDES
6" x 6" CENTER
PIER ON ALL
SIDES
STRUCTURE LID PER SUDAS
FIT WITH SW-604 TYPE 5 CASTING
3 FT
SECTION
MODIFIED SW-513
OUTLET STRUCTURE
PLAN
MODIFIED SW-513
OUTLET STRUCTURE
NOT TO SCALE
NOT TO SCALE
NOTES:
1. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
2. HICKENBOTTOM INTAKE, WATER LEVEL CONTROL
STRUCTURE, DUAL-WALL HDPE, ELBOW, TRASH GUARD,
CASTING, AND ALL HARDWARE AND APPURTENANCES
SHOWN ON THIS PAGE OR REQUIRED FOR INSTALLATION
ARE SUBSIDIARY TO THE OUTLET STRUCTURE.
36" RCP OUTLET PIPE
OPENINGS FOUR
SIDES WITH
CENTER PIERS
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
B0
1.
dw g 1/
/2
:1
3:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.05
TRASH GUARD & ANTI-SEEP COLLAR DETAIL
1/2" X 2" SLOTTED HOLES
FOR 3/8" DIA. BOLTS
CONTINUOUS WELD
BETWEEN BAND
AND COLLAR.
3.75'
3.75'
12'
SLOTTED HOLES
@ 8" O.C.
CONTINUOUS WELD
BETWEEN BAND
AND COLLAR.
BAND
BOTTOM OF BAND
2" 2"
BAND
A
A
12"TOP OF BAND
BOTTOM OF COLLAR
CORRUGATED METAL SHEET WELDED
TO CENTER OF SMOOTH METAL
BAND WITH MASTIC APPLIED FOR
SEALANT AROUND THE PIPE.
OPTIONAL SUBSTITUTE -
CAST-IN-PLACE CONCRETE BAND.
CORRUGATED METAL SHEET
GALVANIZED STEEL
PREFABRICATED HPDE ANTI-SEEP
COLLARS ARE AN ALLOWED ALTERNATIVE.
BAND
12" ID
RCP
TRENCH WIDTH (SEE PLANS)
5 FT MIN. COLLAR WIDTH
FT
C O
LL
AR
TH
IC
KN
ES
S
NOTES:
1. COMPOSITE BENTONITE AGGREGATE
(CBA) SHALL BE AQUABLOK OR
APPROVED EQUAL.
2. COLLAR SHALL EXTEND 1.75 FT BELOW
BOTTOM OF PIPE AND 1.75 FT ABOVE
TOP OF PIPE
3. COLLAR SHALL BE A MINIMUM OF 5 FT
WIDE AND EXTEND A MINIMUM OF 6"
BEYOND EDGE OF TRENCH
4. NO COMPACTION OF CBA IS
REQUIRED.
5. EXCAVATE AND BACKFILL THE
REMAINDER OF THE TRENCH AS
NOTED IN THE PLANS.
ANTI-SEEP COLLAR DETAILS
ALTERNATIVE 2: COMPOSITE BENTONITE AGGREGATE
COLLAR
NOT TO SCALE
ALTERNATIVE 1: RCP ANTI-SEEP COLLAR
NOT TO SCALE
48"
SHEET STEEL
SHEET STEEL
90"
GROUND CONTACT
TREATED POST
4"x4"
MODIFIED SW-513
OUTLET STRUCTURE
12" MIN. SPACE
BELOW GUARD
24"
CONCRETE FOOTINGS
MIN 12" DIAMETER
4 FT MIN.
EMBEDMENT
STRUCTURE
OPENING
BOLT SHEET STEEL TO
ANGLE IRON ANCHORED
ONTO STRUCTURE
GRADE BELOW TRASH
GUARD TO PROVIDE 12"
MINIMUM SPACE
BETWEEN BOTTOM OF
STEEL AND TOP OF RIP RAP
(TYP. ALL SIDES)
SHEET STEEL
TRASH GUARD FOR WETLAND OUTLET STRUCTURE
NOT TO SCALE
NOTE: TRASH GUARD AND APPURTENANCES ARE TYPICAL FOR ALL SIDES OF OUTLET STRUCTURE. QUANTITIES
AND DIMENSIONS FOR STEEL SHEETS PER SIDE OF STRUCTURE ARE AS FOLLOWS:
1 - STEEL SHEET - 90" x 24" x 3/8" 2 - STEEL SHEETS - 48" x 24" x 3/8"
ANGLE IRON--EITHER WELDED OR BOLTED--ON TOP AND BOTTOM OF EACH SHEET AS BRACE.
BOLT TRASH GUARD ONTO ANGLE IRON ANCHORED TO OUTLET STRUCTURE.
PROVIDE THREE POSTS WITH CONCRETE FOOTINGS ON EACH SIDE
GRADE AS NECESSARY TO ALLOW FLOW OF WATER UNDER TRASH GUARD WITH 12" MINIMUM CLEARANCE.
ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
C0
1.
dw g 1/
/2
:1
3:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
C.01
ESTIMATED QUANTITIES
Bid Item Description Specifications
Plan No.
Estimated Quantities
No. Page Quantity Unit
1 Site Stripping & Preparation IA CS-001 3 A.02 1 LS
2 Crop Damage IA CS-001 3 0 AC
3 Structure and Channel Seeding IA CS-006 7 K.01 0.7 AC
4 Buffer Seeding IA CS-006 7 K.01 10.8 AC
5 Mobilization and Demobilization IA CS-008 11 1 LS
6 Excavation (General) IA CS-021 16 D.01 34,679 CY
7 Earthfill (General) IA CS-023 19 D.01 64 CY
8 Earthfill (General Dam) IA CS-023 19 D.01, D.03-D.04 317 CY
9 Earthfill (Dam Core) IA CS-023 19 D.04 1,110 CY
10 Topsoil Strip, Salvage, and Respread IA CS-026 23 D.01 8,593 CY
11 18" Dia. Reinforced Concrete Pipe IA CS-031 25 B.01, M.01 190 LF
12 36" Dia. Reinforced Concrete Pipe IA CS-031 25 B.01, M.01 150 LF
13 18" Dia. Concrete Apron, Footing, Bar Guard IA CS-031 25 M.01 1 EA
14 36" Dia. Concrete Apron, Footing, Bar Guard IA CS-031 25 M.01 1 EA
15 SW-402 Pump Basin IA CS-031 25 B.03, M.01 1 EA
16 Solar Pump System IA CS-031 25 B.03, M.01 2 EA
17 72" x 72" Modified SW-513 Outlet Structure IA CS-031 25 B.04, M.01 1 EA
18 6" Dia. Corrugated HDPE Pipe (Single-Wall; Perforated) IA CS-046 33 B.02, M.02 1,044 LF
19 6" Dia. Corrugated HDPE Pipe (Single-Wall; Non-Perforated) IA CS-046 33 B.02, M.02 85 LF
20 Anti-Seep Collars IA CS-051 37 B.05, M.01 3 EA
21 8" Dia. CMP Tile Outlet (20 LF Each) IA CS-051 37 M.02 1 EA
22 Rip Rap (Class E) IA CS-061 41 M.01 42.7 TN
BULAND, BETTY B
SMALLEY,
RAYMOND L
STORY COUNTY
STORY COUNTY
LARSON BROTHERS LLC
LARSON, SHANE
LARSON BROTHERS LLC
LARSON, SHANE
BULAND, BETTY BBULAND, BETTY B
BULAND, BETTY B
BULAND, BETTY B GUSTAFSON,
DELWIN J & CINDY GUSTAFSON, DELWIN J & CINDY
10 FT EMBANKMENT
TOP ELEV. 856.00
50 FT INLET CHANNEL
ELEV. 854.00
10:1 SIDES
NWL = 855.00
EXCAVATE POOL TO 854.00
GRADE OUT AT 10:1
EXCAVATE TO 854.00
50 FT AUXILIARY SPILLWAY
CREST ELEV. 855.50
3:1 SIDES
PROPERTY LINES
EXCAVATE CHANNEL TO 854.00
GRADE OUT AT 10:1
EXCAVATE TO 853.00
440'x17' 4:1 SIDES85
855 856
855854
EXCAVATE TO 852.50
50'x50' 4:1 SIDES
EXCAVATE TO 853.00
440'x17' 4:1 SIDES
EXCAVATE TO 852.50
50'x50' 4:1 SIDES
EXCAVATE TO 852.50
50'x50' 4:1 SIDES
EXCAVATE TO 852.50
50'x50' 4:1 SIDES
SPOIL PILE
SPOIL PILE
10 FT COVER BERM
SEE M.01
4:1 SIDES
10 FT EMBANKMENT
TOP ELEV. 856.00
4:1 SIDES
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
MINIMUM 6" TOPSOIL LAYER
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
D0
1.
dw g 1/
/2
:1
4:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
D.01
GRADING OVERVIEW
R
FEETSCALE
0 100 200
HORZ.
0+50 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 12+50
9.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
VPI: 2+15.24
EL: 856.94
VPI: 2+27.00
EL: 854.00
VP
I:
+1
7.
EL
: 8
.9
9EXISTING GROUND SURFACE NWL = 855.00
END INLET CHANNEL
BEGIN POOL
INLET CHANNEL
EXCAVATE TO 854.00
50 FT INLET CHANNEL
EXCAVATE TO 854.00
0+00
1+00
2+00
3+00
4+00
5+00
6+00
7+00
8+00
9+00
10+00 11+00
12+00
12+50
BP
: 0
+0 0.
PC
: 1
0+
.4
PT: 11+23.74
EP: 12+50.00
858 857
855 854
PUMP INLET PIPE
SEE M.01
EXCAVATION SPOIL PILE
EXCAVATION SPOIL PILE
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
D0
2.
dw g 1/
/2
:1
4:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 40 80
HORZ.
FEETSCALE
0 5 10
VERT. D.02
INLET CHANNEL
INLET CHANNEL
3:1 SIDES
INLET CHANNEL TYPICAL SECTION
EXISTING GROUND
50 FT BOTTOM
-1+00 0+00 1+00 2+00 3+00 4+00
5.
6.
5.
5.
5.
6.
6.
6.
6.
6.
0.00%VP
I:
0+
.0
EL
: 8
.0
VP
I:
2+
.3
EL
: 8
.0
010 FT EMBANKMENT
TOP ELEV. 856.00
EXISTING GROUND SURFACE
0+00 1+00 2+00 3+00
BP
: 0
+0 0.
EP
: 3
+0 0.
+0
855854
-1+00 0+00 1+00 2+00 3+00 4+00
5.
5.
5.
6.
6.
4.
5.
5.
4.
0.00% -0.75%
VP
I:
0+
.3
EL
: 8
.5
VP
I:
1+
.0
EL
: 8
.5
VP
I:
2+
.1
EL
: 8
.5
EXISTING GROUND SURFACE 50 FT AUXILIARY SPILLWAY
CREST ELEV. 855.50
0+00
1+00
2+00
3+00
BP: 0+00.00
PC: 1+50.00
PT
: 2
+0 4.9
EP
: 3
+0 0.0
WETLAND OUTLET PIPE
SEE M.01
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
D0
2.
dw g 1/
/2
:1
4:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 40 80
HORZ.
FEETSCALE
0 5 10
VERT. D.03
NORTHEAST BERM & AUXILIARY SPILLWAY
R
NORTHEAST BERM TYPICAL SECTION
EXISTING GROUND
10 FT TOP
4:1
4:1
AUXILIARY SPILLWAY TYPICAL SECTION
EXISTING GROUNDTOP OF
EMBANKMENT
50 FT BOTTOM
3:1 3:1
NORTHEAST BERM AUXILIARY SPILLWAY
-1+25 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 10+75
6.
6.
6.
5.
5.
5.
5.
5.
5.
5.
5.
4.
4.
4.
4.
5.
5.
4.
5.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
6.
0.00%VP
I:
1+
.7
EL
: 8
.0
VP
I:
9+
.7
EL
: 8
.0
010 FT EMBANKMENT
TOP ELEV. 856.00
EXISTING GROUND SURFACE
NWL = 855.00
BOTTOM OF CORE TRENCH
5 FT BELOW EXISTING
GROUND SURFACE
TOP OF CORE TRENCH AT NWL
ELEV. 855.00
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 9+50
BP
: 0 +0
0.
EP
: 9
+5 0.
855856 856855
85586
WETLAND OUTLET PIPE
SEE M.01
EXCAVATION SPOIL PILE
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
D0
2.
dw g 1/
/2
:1
4:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 40 80
HORZ.
FEETSCALE
0 5 10
VERT. D.04
SOUTH BERM
SOUTH BERM
SOUTH BERM TYPICAL SECTION
EXISTING GROUNDEXCAVATED
POOL
4:14:1
10 FT TOP
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00
5.
6.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
6.
6.
9.
8.
7.
7.
3.
3.
4.
3.
2.
2.
2.
2.
2.
2.
2.
2.
2.
3.
NWL = 855.00
EXCAVATION SPOIL PILE
WETLAND DEEP CHANNEL
BOTTOM ELEV. 853.00
EXCAVATED WETLAND POOL
BOTTOM ELEV. 854.00
EXISTING GROUND SURFACE
EXISTING GROUND SURFACE
NWL = 855.00
50 FT INLET CHANNEL
BOTTOM ELEV. 854.00
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00
BP
: 0
+0 0.
EP
: 1
2+
.0
EXCAVATION SPOIL PILE
EXCAVATION SPOIL PILE
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
D0
2.
dw g 1/
/2
:1
4:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 40 80
HORZ.
FEETSCALE
0 5 10
VERT. D.05
NORTH POOL CROSS SECTION (E-W)
NORTH POOL CROSS SECTION (E-W)
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00
6.
6.
6.
6.
6.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
6.
6.
9.
8.
8.
4.
5.
6.
7.
8.
9.
5.
3.
3.
2.
2.
2.
2.
2.
2.
2.
2.
2.
3.
NWL = 855.00
EXCAVATION SPOIL PILE
WETLAND DEEP CHANNEL
BOTTOM ELEV. 853.00
EXCAVATED WETLAND POOL
BOTTOM ELEV. 854.00
EXISTING GROUND SURFACE
EXISTING GROUND SURFACE
50 FT INLET CHANNEL
BOTTOM ELEV. 854.00
EXCAVATION SPOIL PILE
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00
BP
: 0
+0 0.
EP
: 1
2+
.0
EXCAVATION SPOIL PILE
EXCAVATION SPOIL PILE
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
D0
2.
dw g 1/
/2
:1
4:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 40 80
HORZ.
FEETSCALE
0 5 10
VERT. D.06
SOUTH POOL CROSS SECTION (E-W)
SOUTH POOL CROSS SECTION (E-W)
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00
6.
6.
6.
6.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
5.
1.
1.
1.
1.
1.
9.
7.
5.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
5.
NWL = 855.00
EXCAVATION SPOIL PILE
WETLAND DEEP CHANNEL
BOTTOM ELEV. 853.00
EXCAVATED WETLAND POOL
BOTTOM ELEV. 854.00
EXISTING GROUND SURFACE
EXISTING GROUND SURFACE
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00
BP
: 0
+0 0.
EP
: 1
2+
.0
856857858
856857
855 854
EXCAVATION SPOIL PILE
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
D0
2.
dw g 1/
/2
:1
4:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 40 80
HORZ.
FEETSCALE
0 5 10
VERT. D.07
POOL CROSS SECTION (N-S)
POOL CROSS SECTION (N-S)
SEED EXCAVATION SPOIL PILE EXTENTS
BUFFER SEEDING
SEED EXCAVATION SPOIL PILE EXTENTS
BUFFER SEEDING
SEED DISTURBED AREAS TO 1 FT
BELOW NORMAL POOL
BUFFER SEEDING
SEED DISTURBED AREAS TO 1 FT
BELOW NORMAL POOL
BUFFER SEEDING
SEED NORTHEAST BERM
STRUCTURE SEEDING
SEED SOUTH BERM
STRUCTURE SEEDING
SEED AUXILIARY SPILLWAY
AND SURROUNDING AREA
STRUCTURE SEEDING
SEED OUTLET PIPE COVER BERM
STRUCTURE SEEDING
DO NOT SEED POOL
SEEDING AREAS
BUFFER SEEDING 10.8 AC
STRUCTURE SEEDING 0.7 AC
7 85
856856
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
K0
1.
dw g 1/
/2
:1
4:
P M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
K.01
SEEDING PLAN
R
FEETSCALE
0 100 200
HORZ.
-0+50 0+00 1+00 2+00 3+00
7.
9.
9.
7.
6.
6.
6.
6.
6.
7.
6.
7.
9.
9.
7.
6.
6.
6.
6.
6.
6.
6.
-1.00%
VPI: 0+30.00
EL: 849.00
VPI: 2+20.00
EL: 847.10
190' - 18" RCP @ 1.00%
190 LF - 18" RCP
@ 1.00% 2030
PU
M
P
BA
SI
N
(S
TA
+2
0) M
O
DI
FI
ED
S W
-4
SE
E
B.
TO
P
0.
FL
IN
.1
(1
8" S
ST
A
0+
" C
O N
CR
ET
E
AP
RO
N
FO
O
TI
N G, B
AR
G U
AR
D
FL
O
U T
9.
(1 8"
N
EXCAVATED WETLAND POOL
EXISTING GROUND SURFACE
NWL = 855.00
0+00 1+00 2+00 2+50
BP
: 0
+0 0.
EP
: 2
+5 0.
EXCAVATION
SPOIL PILE
EXCAVATION
SPOIL PILE
50-FT WIDTH TREE
REMOVAL OVER PIPE
RIP RAP
6 FT x 27 FT
12.8 TONS
RIP RAP
10 FT x 12 FT
9.5 TONS
STA 0+30
18" CONCRETE APRON,
FOOTING, BAR GUARD
FL OUT = 849.00 (18" N)
PUMP BASIN (STA 2+20)
MODIFIED SW-402
SEE B.03
TOP = 860.00
FL IN = 847.10 (18" S)
INSTALL SOLAR PANELS ON
POSTS ABOVE ELEV. 865.00
-0+75 0+00 1+00 2+00 2+75
4.
4.
4.
5.
4.
3.
7.
6.
8.
7.
4.
4.
4.
5.
4.
3.
7.
6.
8.
6.
-0.67%
.00
% -0.65%
150' - 36" RCP @ 0.67%
150 LF - 36" RCP
@ 0.67% 9545
O U
TL
ET
S
TR
U
CT
U
RE
(S
TA
+4
5) M
O
DI
FI
ED
S W
-5
"x
SE
E
B.
TO
P
6.
O
PE
N
IN
G
5.
FL
O U
T
0.
(3
6" S
ST
A
1+
" C
O N
CR
ET
E
AP
RO
N
FO
O
TI
N G, B
AR
G U
AR
D
FL
IN
.0
(3
6" N
VPI: 0+45.00
EL: 850.00 VPI: 1+95.00
EL: 849.00
COVER BERM
3 FT COVER REQUIRED
EXCAVATED WETLAND POOL
NWL = 855.00
EXISTING GROUND SURFACE
10 FT EMBANKMENT
SEE D.04
ANTI-SEEP COLLARS
SEE B.05
0+00 1+00 2+00 2+25
BP
: 0
+0 0.
EP
: 2
+2 5.
RIP RAP
12 FT x 20 FT
18.9 TONS
50-FT WIDTH TREE
REMOVAL OVER PIPE
RIP RAP
SEE B.04
1.5 TONS
OUTLET STRUCTURE (STA 0+45)
MODIFIED SW-513
72"x72"
SEE B.04
TOP = 856.25
OPENING = 855.00
FL OUT = 850.00 (36" S)
STA 1+95
36" CONCRETE APRON,
FOOTING, BAR GUARD
FL IN = 849.00 (36" N)
10 FT COVER BERM
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
R
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. M.01
PUMP INLET PIPE & WETLAND OUTLET PIPE
R
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
M
.d w g
1/
/2
:1 4:
P
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
PUMP INLET PIPE WETLAND OUTLET PIPE
10 FT TOP
4:1 SIDES
COVER BERM TYPICAL SECTION
EXISTING GROUND
0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00
6.
6.
6.
6.
6.
6.
6.
6.
5.
5.
5.
5.
6.
6.
5.
6.
6.
0.
2.
2.
2.
2.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
1.
-0.10%
VP
I:
0+
.0
EL
: 8
.2
VP
I:
+5
4.
EL
: 8
.0
1044' - 6" HDPE @ 0.10%
1044 LF - 6" PERFORATED HDPE
@ 0.10% 4905
85' - 6" HDPE @ 0.10%
85 LF - 6" NON-PERFORATED HDPE
@ 0.10% 34
EXISTING GROUND SURFACE
NON-PERFORATED PIPE OUTSIDE OF CROP LAND
20 LF 8" CMP TILE OUTLET
EXISTING GROUND SURFACE
0+00 1+00
2+00 3+00
4+00 5+00
6+00 7+00
8+00 9+00
10+00
11+00
12+00
BP
: 0
+0 0.
PI
: 1
0+
.7
EP: 12+00.00
20 LF 8" CMP TILE OUTLET
50-FT WIDTH TREE
REMOVAL OVER TILE
855854
NORMAL POOL (855.00)
100-YEAR HWL (855.95)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 854.00
MICROTOPOGRAPHY
TREE REMOVAL
STRUCTURE SEEDING
LEGEND
R
FEETSCALE
0 40 80
HORZ.
FEETSCALE
0 5 10
VERT. M.02
RING TILE
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c H:
\I
DA
LS
\2
5X
0\
CA
D\
C3 D\
M
.d w g
1/
/2
:1 4:
P
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
STO822305D - BULAND WETLAND
BCS
NVD
JPR
25X.138710.000
1519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
RING TILE
| Sheets and Views |
| A.01 TITLE SHEET |
| A.02 PLAN OVERVIEW SHEET |
| B.01 RCP INSTALLATION DETAIL |
| B.02 CPDT INSTALLATION DETAIL |
| B.03 PUMP BASIN DETAIL |
| B.04 WETLAND OUTLET STRUCTURE DETAIL |
| B.05 TRASH GUARD & ANTI-SEEP COLLAR DETAIL |
| C.01 ESTIMATED QUANTITIES |
| D.01 GRADING OVERVIEW |
| D.02 INLET CHANNEL |
| D.03 NORTHEAST BERM & AUXILIARY SPILLWAY |
| D.04 SOUTH BERM |
| D.05 NORTH POOL CROSS SECTION (E-W) |
| D.06 SOUTH POOL CROSS SECTION (E-W) |
| D.07 POOL CROSS SECTION (N-S) |
| K.01 SEEDING PLAN |
| M.01 PUMP INLET PIPE & WETLAND OUTLET PIPE |
| M.02 RING TILE |
File details come from the government source that posted it. Updated .