Plans.pdf
PDF 7 MB Posted
- Attached to
- 26-11 Cla953734C (Clay) RFB
- Solicitation number
- 26-11 Cla953734C (Clay)
- Issued by
- Clinton County, Iowa
About this file
This construction plans document, prepared by Bolton & Menk, Inc. for the Iowa Department of Agriculture and Land Stewardship (IDALS), details the final design for a nutrient reduction wetland project in Clay County, Iowa, with project number CLA953734C dated June 2026. The project involves constructing a 20.4-acre easement area with a wetland pool featuring a normal water level of 1360.00 feet, incorporating a 49-foot sheet pile weir, modified SW-402 water control structure, auxiliary spillway, stilling basin, and outlet channel. Key construction components include excavation of 10,944 cubic yards of general material and 2,283 cubic yards for the dam, installation of 2,523 square feet of steel sheet piling, placement of 1,210 cubic yards of general earthfill and 767 cubic yards of dam core material, installation of 30-inch and 12-inch reinforced concrete pipe (805 and 152 linear feet respectively), 540 linear feet of 6-inch corrugated high-density polyethylene tile, and 383 tons of Class E riprap. Additional work includes site stripping, drain tile investigation and removal, seeding of 2.1 acres for structures and channels plus 13.1 acres for buffer areas, and miscellaneous details such as anti-seep collars, drawdown pipes, and outlet riser structures.
The construction specifications reference the Natural Resources Conservation Service standards, Iowa Department of Transportation specifications, and current Iowa Statewide Urban Standard Specifications for Public Improvements. The project utilizes NRCS Job Class IV standards for the constructed wetland practice (Standard 656). Subsurface utility information is classified as Quality Level D per CI/ASCE 38-02 guidelines, and contractors are required to contact Iowa One Call at 811 before commencing work. The estimated total quantities include 16 linear feet of 12-inch reinforced concrete pipe, 136 linear feet of 12-inch gasketed pipe, one water control structure, one outlet riser structure, and two anti-seep collars, among other specified items detailed in the estimated quantities sheet (C.01). The professional engineer of record is Brandon C. Short, PE (License No. 29449), with a renewal date of December 31, 2026, and the document is sealed and certified for construction in Clay County, Iowa.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Book.pdf | ||
| Specifications.pdf | ||
| Schedule of Prices.pdf | ||
| Design Report.pdf | ||
| Doc CC Proposal - Acknowledgement - Affidavit.pdf | ||
| Doc EE Bid Bond.pdf | ||
| Wetland QA QC Plan.pdf | ||
| Notice to Bidders 09-25-26.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
10 10
A
V E
A V
E
A
V
E492 ST
A V
E
390 ST
A V
E
440 ST
A V
E
A V
E
450 ST
460 ST
A V
E
490 ST
5 A
VE
A
VE
450 ST
460 ST
A V
E
A
V E
A V
E
A V
E
A V
E
470 ST
0 A
VE
A
VE
A V
E
400 ST
410 ST
A V
E
A V
E
420 ST
430 ST
485 ST
480 ST
A V
E
480 ST
485 ST
A V
E
A V
E
480 ST
A V
E
A V
E
A V
E
440 ST
A V
E
435 ST20
A
VE
A V
E
440 ST
400 ST
A V
E
400 ST
A V
E
A
VE
440 ST
440 ST
A V
E
A
VE
A V
E
470 ST
490 ST
A V
E
A V
E
500 ST
450 ST
A V
E
A V
E
460 ST
475 ST
470 ST
A V
E
490 ST
A V
E
505 ST
0 S
T 510 ST
500 ST
450 ST450 ST
460 ST
A V
E
460 ST
A V
E
470 ST
A V
E 480 ST
490 ST
A V
E
A V
E
A V
E
490 ST
505 ST
410 ST
420 ST
430 ST
390 ST
390 ST
A V
E
A V
E
A
VE
A V
E
400 ST
410 ST
420 ST 420 ST
430 ST
A V
E
A V
E
430 ST
A V
E
390 ST
390 ST
A V
E
A V
E
A V
E
410 ST
410 ST
420 ST
A
VE
430 ST
A V
E
A V
E
485 ST
A V
E
ST
A V
E
A V
E
400 ST
400 ST
505 ST 245AVE
480 ST
495 ST
145 A V
E
ROYAL
ROSSIE GREENVILLE
PETERSON
Creek
Prairie
Willow
Creek
WANATA
STATE
PARK
C L A Y L I N C O L N
H E R D L A N D
D O U G L A S
P E T E R S O N
G I L L E T T
G R O V E
7 8 9
161718
19 20 21
282930
31 32 33
7 8 9
161718
20 21
282930
31 32 33
12345
7 8 9 10 11 12
131415161718
19 20 21 22 23
252627282930
31 32 33 34 35 36
123456
7 8 9 10 11 12
131415161718
19 20 21 22 23 24
27282930
31 32 33 34 35 36
123456
7 8 9 10 11
131415161718
19 20 21 22 23 24
252627282930
31 32 33 34 35 36
123456
7 8 9 10 11 12
131415161718
19 20 21 22 23 24
31 32 34 35 36
B40 M36
B46
B46
B40 M27
M36
M36
B63
B53B53
M27
M27
B61
M36
M50
B53
B40B40
CORNELL
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
A0
1.
dw g 6/
1/
:0 7:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
A.01
TITLE SHEET
PROJECT DATUM: STATE PLANE
HORIZONTAL: IOWA NORTH
VERTICAL: NAVD 1988
MY LICENSE RENEWAL DATE IS
PAGES OR SHEETS COVERED BY THIS SEAL:
LICENSE NUMBER: DATE:
I OWA
LI
CE
NS
ED
PROFESS IONAL ENG
INEER
I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS
PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION
AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER
UNDER THE LAWS OF THE STATE OF IOWA.
29449
12/31/2026
ALL SHEETS
BRANDON C.
SHORT
29449
BRANDON C. SHORT, PE
CLAY COUNTY, IA
CONSTRUCTION PLANS FOR
IDALS NO. CLA953734C
NUTRIENT REDUCTION WETLAND
CLAY COUNTY, IOWA
JUNE 2026
THE SPECIFICATIONS AS PREPARED BY IOWA DEPARTMENT OF AGRICULTURE
AND LAND STEWARDSHIP AND BOLTON & MENK, INC. SHALL BE CONSIDERED
AS PART OF THIS DOCUMENT. NATURAL RESOURCES CONSERVATION SERVICE
CONSTRUCTION SPECIFICATIONS SHALL APPLY.
THE CURRENT EDITION OF THE "IOWA STATEWIDE URBAN STANDARD
SPECIFICATIONS FOR PUBLIC IMPROVEMENTS" SHALL GOVERN.
IOWA DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATIONS FOR
HIGHWAY AND BRIDGE CONSTRUCTION" AND ALL CURRENT GENERAL
SUPPLEMENTAL SPECIFICATIONS AND MATERIALS INSTRUCTIONAL
MEMORANDUM SHALL GOVERN AS REFERENCED.
ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND ORDINANCES WILL BE
COMPLIED WITH IN THE CONSTRUCTION OF THIS PROJECT.
GOVERNING SPECIFICATIONS
THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS
UTILITY QUALITY LEVEL D. THIS UTILITY QUALITY LEVEL WAS
DETERMINED ACCORDING TO THE GUIDELINES OF CI/ASCE
38-02, ENTITLED "STANDARD GUIDELINES FOR THE
COLLECTION AND DEPICTION OF EXISTING SUBSURFACE
UTILITY DATA."
THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING IOWA
ONE CALL BY PHONE AT 811, OR ON THE WEB AT
HTTP://WWW.IOWAONECALL.COM/. TICKET# ___________.
TICKET NUMBER MUST BE PROVIDED TO THE NRCS PRIOR TO
COMMENCEMENT OF WORK.
NOTES
1. IF A CULTURAL RESOURCE IS IDENTIFIED DURING
CONSTRUCTION, STOP WORK IMMEDIATELY AND NOTIFY
THE LOCAL NATURAL RESOURCES CONSERVATION SERVICE
OFFICE.
2. THERE IS NO GUARANTEE THAT THE WETLAND WILL FILL OR
REMAIN FILLED WITH WATER.
R-36W
T-
N
PROJECT
LOCATION
R-37W
T-
N
CONSERVATION PRACTICE STANDARDS USED:
656 - CONSTRUCTED WETLAND
NRCS JOB CLASS: IV
300 AC<WATERSHED AREA<1000 AC
TO THE BEST OF MY PROFESSIONAL KNOWLEDGE,
JUDGEMENT, AND BELIEF, THESE PLANS MEET APPLICABLE
NRCS STANDARDS AND APPLICABLE LAWS AND
REGULATIONS.
R
MILESSCALE
0 1 2
R-36WR-38W
T-
N
R-37WR-38W
T-
N
SHEET INDEX
SHEET NO. SHEET TITLE
A.01 TITLE SHEET
A.02 PLAN OVERVIEW
A.03 EXISTING CONDITIONS AND REMOVALS
B.01 WATER CONTROL STRUCTURE DETAILS
B.02 SHEET PILE DETAILS
B.03 CPDT INSTALLATION DETAILS
B.04 RCP INSTALLATION DETAILS
B.05 MISCELLANEOUS DETAILS
C.01 ESTIMATED QUANTITIES
D.01 GRADING OVERVIEW
D.02 PLAN & PROFILE - EMBANKMENT
D.03 PLAN & PROFILE - STILLING BASIN & OUTLET
CHANNEL
D.04 PLAN & PROFILE - AUXILIARY SPILLWAY
D.05 PLAN & PROFILE - DIVERSION BERMS
K.01 SEEDING OVERVIEW
M.01 PLAN & PROFILE - TILE MAIN RE-LAY
M.02 PLAN & PROFILE - DRAWDOWN PIPE & NEW TILE
INSTALLATION
brandon.short Text Box 06/10/2026
KRACHT, DUANE & ERNETA
BINDER, ADAM & KRISTINE
BINDER, ADAM &
KRISTINE
KRACHT, DUANE & ERNETA
KRACHT, DUANE & ERNETA
KRACHT, DUANE & ERNETA
68 13
72 13
49 FT SHEET PILE WEIR
ELEV. 1360.00
PROPOSED EASEMENT BOUNDARY
100-YEAR HWL = 1363.49
PROPERTY LINES
RE-LAY 30" RCP TILE MAIN
DAYLIGHT ELEV. 1361.00
TOE DRAINS
DRAWDOWN PIPE OUTLET RISER STRUCTURE
EXCAVATE TO 1359.00
FILL TO 1357.50DEEP WATER AREA (< 1357.00)
NWL = 1360.00
DIVERSION BERMS
TOP ELEV. 1359.50
EXISTING 6 FT BY
6 FT CONCRETE
BOX CULVERT
BORROW AREA
BORROW AREA
SPOIL AREA
EXISTING 18" TILE MAIN
INSTALL 6" HDPE TILE
TILE SEARCH
RE-LAY IF PRESENT TILE SEARCH
RE-LAY IF PRESENT
TILE SEARCH
RE-LAY IF PRESENT
TILE SEARCH
RE-LAY IF PRESENT
REMOVE EXISTING
GRADE CONTROL
STRUCTURE
35 FT AUXILIARY SPILLWAY
ELEV. 1362.75
SEE D.04
74 1376 1378 1382
8 FT COVER BERM
TOP ELEV. 1367.00
SEDIMENT FOREBAY
BOTTOM ELEV. 1356.00
WATER CONTROL STRUCTURE
MODIFIED SW-402
10 FT EMBANKMENT
TOP ELEV. 1364.50
CONSTRUCTION ACCESS
NORMAL POOL (1360.00)
DEEP WATER AREA (<1357.00)
100-YEAR HWL (1363.49)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1359.00
FILL TO 1357.50
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
A0
2.
dw g 6/
1/
:0 7:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
A.02
PLAN OVERVIEW
R
FEETSCALE
0 75 150
HORZ.
DESIGN CRITERIA VALUE UNIT REQUIREMENT
WATERSHED AREA 990 ACRES
POOL NORMAL WATER LEVEL (NWL) ELEV 1360.00 FT
DESIGNED WETLAND POOL AREA (@ NWL) 5.5 ACRES
PERCENT POOL AREA TO WATERSHED AREA 0.6 % Range 0.5% to 2% of watershed area
MAXIMUM POOL DEPTH 5.0 FT
AVERAGE POOL DEPTH 2.2 FT
DEEP WATER AREA (DEPTH > 3 FT) 1.1 ACRES
PERCENT DEEP WATER TO POOL AREA 19.9 % Less than 25%
POOL STORAGE VOLUME AT NWL 11.9 ACRE-FT
OVERFLOW ELEVATION 1362.75 FT
POOL STORAGE VOLUME AT OVERFLOW 28.2 ACRE-FT
PRIMARY WEIR ELEVATION 1360.00 FT
PRIMARY WEIR WIDTH 49 FT
TOTAL EASEMENT AREA 20.4 ACRES
AREA OF BUFFER 14.9 ACRES
RATIO BUFFER AREA TO NWL POOL AREA 2.7 Less than 4
25-YEAR STORM HWL IN POOL 1362.64 FT
25-YEAR PEAK INFLOW 672 CFS
25-YEAR PEAK OUTFLOW 656 CFS
100-YEAR STORM HWL IN POOL 1363.49 FT
100-YEAR PEAK INFLOW 1030 CFS
100-YEAR PEAK OUTFLOW 1016 CFS
WETLAND ELEV INCREMENTAL CUMULATIVE CUMULATIVE
POOL DEPTH AREA VOLUME VOLUME
(FT) (FT) (FT2
) (FT3
) (AC-FT)
0.0 1355.0 1,446
1.0 1356.0 29,170 15,308 0.35
2.0 1357.0 50,127 54,957 1.26
3.0 1358.0 95,265 127,653 2.93
4.0 1359.0 225,017 287,794 6.61
5.0 1360.0 240,400 520,502 11.95
6.0 1361.0 252,922 767,163 17.61
7.0 1362.0 264,840 1,026,044 23.55
7.8 1362.75 276,113 1,228,901 28.21
8.0 1363.0 279,974 1,298,451 29.81
9.0 1364.0 300,328 1,588,602 36.47
9.5 1364.5 318,896 1,743,408 40.02
13701370
REMOVE EXISTING LIVESTOCK SHELTER
PRESERVE EXISTING 6 FT x 6 FT
CONCRETE BOX CULVERT
PRESERVE EXISTING 18" CMP CULVERT
REMOVE EXISTING TILE
OR CRUSH IN PLACE
REMOVE EXISTING TILE
OR CRUSH IN PLACE
REMOVE EXISTING TILE
OR CRUSH IN PLACE
PRESERVE EXISTING 18" CMP CULVERT
ABANDON EXISTING TILE IN PLACE
FILL WITH GROUT
REMOVE EXISTING GRADE
CONTROL STRUCTURE & RUBBLE
REMOVE TREES WITHIN EASEMENT
PROPOSED EASEMENT BOUNDARY
EXISTING TILE
TILE REMOVAL
LEGEND
>>506 51080004
80000
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
A0
3.
dw g 6/
1/
:0 7:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
A.03
EXISTING CONDITIONS AND REMOVALS
R
FEETSCALE
0 60 120
HORZ.
BENCHMARK LOCATIONS
NOTE: TILE REMOVALS SHALL
INCLUDE A MINIMUM OF 20 FT OF
TILE REMOVED EVERY 100 FT.
BENCHMARKS
POINT NO. NORTHING EASTING ELEVATION DESCRIPTION
500 3833276.160 4463594.028 1390.68 5/8" REBAR LAND MARKER - BLUE METAL CAP
505 3833231.762 4466247.842 1377.61 1/2" REBAR LAND MARKER - YELLOW PLASTIC CAP
506 3830551.418 4466291.786 1394.73 5/8" REBAR LAND MARKER
510 3830488.550 4468930.299 1394.89 5/8" REBAR LAND MARKER
80000 3835924.809 4463550.929 1402.49 1" METAL ROD
80004 3830611.406 4463652.592 1375.31 1" TEAL PIPE - YELLOW PLASTIC CAP
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 6/
1/
:0 8:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.01
WATER CONTROL STRUCTURE DETAILS
COVER/STOP LOG STORAGE NOTES:
1. PROVIDE HALLIDAY PRODUCTS MODEL S1R3648 (OR APPROVED EQUAL) 36" x 48" ALUMINUM
ACCESS DOOR WITH LOCKING MECHANISM AND LIFTING HANDLE.
2. TOP OF STRUCTURE SHALL BE AN 8" THICK REINFORCED PRECAST TOP WITH ALUMINUM ACCESS
DOOR CAST INTO TOP.
3. PROVIDE 24" GRATE AND COLLAR (AGRI DRAIN GR24 GRATE AND GRC24 COLLAR OR APPROVED
EQUAL) FOR STOP LOG STORAGE.
4. PADLOCKS FOR ACCESS DOOR AND STOP LOG STORAGE TUBE SHALL BE KEYED ALIKE. FOUR KEYS
ARE TO BE SUPPLIED UPON PROJECT COMPLETION.
STOP LOG CHANNEL NOTES:
1. ALL STEEL SHALL BE FY=36 KSI.
2. ANCHORS SHALL BE GALVANIZED STEEL FURNISHED W/NUTS, WASHERS AND LOCK WASHERS.
3. STOP LOG CHANNEL SHALL BE FURNISHED AS ONE CONTINUOUS PIECE W/CONTINUOUS WELDS.
4. ALL STEEL STOP LOG CHANNEL COMPONENTS ARE TO BE GALVANIZED AFTER WELDING AND
DRILLING IS COMPLETE.
5. CONTRACTOR IS TO APPLY SEALANT VERY GENEROUSLY TO BACKSIDE OF STOP LOG CHANNEL TO ENSURE WATERTIGHT SEAL. SEALANT SHALL BE SIKA 30 YEAR INDUSTRIAL CAULK IN LIMESTONE
GREY OR APPROVED EQUIVALENT.
WATER CONTROL STRUCTURE NOTES:
1. STRUCTURE FABRICATION AND INSTALLATION SHALL CONFORM TO SUDAS 6010.302 SW-402
RECTANGULAR STORM SEWER MANHOLE
2. STRUCTURE SHOP DRAWINGS ARE REQUIRED FOR ENGINEER'S REVIEW AND APPROVAL BEFORE
FABRICATION OF WATER CONTROL STRUCTURE.
3. PRECAST WATER CONTROL STRUCTURE SHALL BE SUPPLED IN 2 OR 3 SECTIONS, PLUS AN 8" THICK COVER SECTION. SECTION SIZE IS LEFT TO CONTRACTOR'S DISCRETION EXCEPT BOTTOM SECTION
SHALL INCLUDE BASE AND WALLS TO 12" ABOVE INLET HOLE.
4. A CONCRETE INVERT IS TO BE INSTALLED AFTER STOP LOG CHANNEL IS INSTALLED. THE BOTTOM STOP LOG IS TO BE CAST INTO THE INVERT WITH THREE HALF INCH DIA. "J BOLTS" FASTENED TO
THE BOTTOM STOP LOG. NO LIFTING HOLES ARE REQUIRED FOR THIS BOTTOM LOG.
5. ALL SECTIONS OF THE STRUCTURE ARE TO HAVE "TONGUE AND GROOVE" JOINTS SEALED WITH O
RING GASKETS IN THE JOINT AND MASTIC AND FABRIC WRAP ON THE STRUCTURE EXTERIOR.
6. INTERIOR JOINTS SHALL BE FILLED AND SEALED TO PREVENT WATER FLOW IN JOINT BEHIND STOP
LOG CHANNEL USING EITHER CONCRETE GROUT OR MASTIC.
7. A-LOK (OR EQUIVALENT) WATERTIGHT SEAL IS REQUIRED FOR UPSTREAM PIPE CONNECTION TO
THE WATER CONTROL STRUCTURE. CONCRETE COLLAR IS REQUIRED FOR DOWNSTREAM
CONNECTION.
8. MANHOLE STEPS ARE TO BE INSTALLED FOR MAINTENANCE ACCESS TO THE STOP LOGS. STEPS
ARE TO BE PER SUDAS SECTION 6010-2-2.13.
9. ENSURE THAT ALL JOINTS ARE WATER-TIGHT AND PROPERLY SEALED
FL
O
W
FLOW
WELD
WELD
3"X2 1/2"X
1/4" ANGLE
6"X6"X 1/4" ANGLE
FL
O
W
PREDRILL 5/8" HOLES
FOR ANCHORS IN ANGLE
1/2"X4" GALVANIZED
ANCHORS @ 16"
SPACING STARTING
FROM TOP
SEALANT SHALL BE
APPLIED TO BACKSIDE OF
STOP LOG CHANNEL
PRIOR TO MOUNTING TO
CONCRETE STRUCTUREALL WELDS ARE TO BE
ENTIRE LENGTH OF
CHANNEL TO ENSURE
WATERTIGHTNESS
NOT TO SCALE
SW-402 WATER CONTROL OUTLET STRUCTURE SECTION
TOP OF STOP LOG
CHANNEL
TOP STOP LOG
AT/ABOVE 100-YEAR HWL
12" RCP FLOWLINE
SEE PLAN & PROFILE12" RCP FLOWLINE
SEE PLAN & PROFILE
POUR 6" CONCRETE INVERT WITH BOTTOM STOP LOG
AND STOP LOG CHANNELS CAST 3" INTO IT. SEE NOTE 4.
9" TOTAL SUMP
EXTERIOR MASTIC &
FABRIC WRAP
ALL JOINTS - 9" WIDE
LOCKING BAR
2"X2"X1/4" ANGLE 36" LONG
INSTALL 1/2" BOLT W/WELDED
NUT AS HINGE AT ONE END.
DRILL 1/2" HOLE FOR PADLOCK AT
OTHER END.
6"X1/2" EYEBOLT CAST
INTO SLAB FOR HINGE
36"X36"X4" CONCRETE
SLAB FLUSH WITH
GROUND W/ GRC24P
COLLAR CAST INTO SLAB
5 LF 24" DIA DUAL WALL
HDPE BURIED FOR STOP
LOG STORAGE TUBE
NOT TO SCALE
COVER AND STOP LOG
STORAGE DETAIL
STOP LOG CHANNEL DETAIL
24" GRATE AND COLLAR
PLACE 8" COMPACTED
ROCK TO SUPPORT TUBE
AND PROVIDE DRAINAGE
ALUMINUM ACCESS DOOR
STOP LOG CHANNEL
TOP OF STRUCTURE (SEE PLAN & PROFILE)
ALL INTERIOR JOINTS TO BE
FILLED WITH CONCRETE
GROUT OR MASTIC
2' MIN.
12" RCP
5'-0"
4' - 0"
5' - 0"
12" RCP
1' 4"
1' 8"
4'
MIN. 12"
8"
2 - 1/2" 2 - 3/4"
CONTRACTOR SHALL GROUT JOINTS
INSIDE STRUCTURE BEHIND
STOPLOG RAILS PRIOR TO
RAIL INSTALLATION
INSTALL STEPS
4' - 0"
1' 8"
TOP OF DIKE (SEE PLAN & PROFILE)
12"
3"
2"
6"
3/16"
3/4"
1" 3"
6"
12"
1/2"
1/2"Φ = 1-3/4"
156"
2"X6" ALUMINUM TUBE
WITH 3/16" WALL THICKNESS
FURNISH & INSTALL 2"X6" ALUMINUM
STOP LOGS AND REMOVAL TOOLS.
LOGS ARE TO BE FINISHED CUT 1"
SHORTER THAN OPENING TO FIT THE
FABRICATED STOP LOG CHANNEL.
NOT TO SCALE
STOP LOG & REMOVAL TOOL
DETAIL
1/2" ROUND
STEEL ROD
PROVIDE TWO
REMOVAL TOOLS
45°
1+00 1+20 1+60 2+00 2+40 2+80 3+20 3+50
.0
.7
.3
.4
.8
.3
.7
.8
.4
.5
.5
.2
.8
.5
.5
.5
EXISTING SURFACE
49' WEIR
TOP OF EMBANKMENT
INSTALL WALER ON TOP
EDGE OF SHEET PILE
STILLING BASIN PROFILE
DOWNSTREAM OF WEIR
SEE SHEET D.03
LINE SHOWN IS THE MINIMUM REQUIRED
COVERAGE LIMIT FOR SHEET PILE INSTALLATION.
PLAN QUANTITY IS BASED ON THESE EXTENTS.
7' 7'
STA: 1+70.49
EL: 1364.50
STA: 1+70.48
EL: 1345.50
STA: 1+84.98
EL: 1334.00
STA: 1+77.49
EL: 1364.50
STA: 1+90.99
EL: 1360.00
STA: 2+39.99
EL: 1360.00
STA: 2+53.49
EL: 1364.50
STA: 2+60.49
EL: 1364.50
STA: 2+60.50
EL: 1345.50
STA: 2+46.00
EL: 1345.50
STA: 2+46.00
EL: 1334.00
STA: 1+84.98
EL: 1345.50
2.
5:
3:1 3:
2.5:1
STA: 2+10.49
EL: 1350.00
STA: 2+20.49
EL: 1350.00
BOTTOM OF DAM CORE
STA: 2+03.25
EL: 1334.00 STA: 2+27.73
EL: 1334.00
STA: 2+03.25
EL: 1318.00
STA: 2+27.73
EL: 1318.00
.0
0' T
O
TA
L
LE
N
GT
H
.0
0' E
M
BE
DM
EN
T
.5
0'
.0
0'
.0
0'
.5
0'
.0
0'
24.48'
14.5'
18.27' 18.27'
14.5'
76'
SHEET
B ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 6/
1/
:0 8:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.02
SHEET PILE DETAILS
NOTES:
1. ALL BOLTS WILL BE 1" DIA. WITH 2 WASHERS. BOLT SHALL BE EXTENDED AT A MINIMUM OF 38" BEYOND THE NUT.
2. ALL HOLES SHALL BE DRILLED 1
16" LARGER IN DIAMETER THAN THE BOLT.
3. THE WALER SHALL BE PLACED ON THE DOWNSTREAM SIDE OF THE WEIR.
4. ANY HOLES LEFT IN SHEET PILE (LIFTING HOLES ETC.) SHALL BE WELDED CLOSED.
5. AFTER SHEETING AND WALER INSTALLATION ALL SHEETING ON THE WEIR IS TO BE CUT TO CONFORM WITH 3:1
SLOPE AND THE DESIGN ELEVATIONS.
6. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDING WITH THE LATEST SPECIFICATION OF AISC.
FABRICATOR SHALL SUBMIT SHOP DRAWINGS SHOWING THAT PLANNED STEEL WILL COMPLETELY COVER
INTENDED WALL AREA. FABRICATE AFTER ENGINEERS REVIEW.
7. DEFLECTIONS SHALL BE MADE IN FABRICATED PIECES AND STILL CONFORM TO THE DIMENSIONS GIVEN.
8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ALLOWABLE CONSTRUCTION LIVE LOADS.
9. PROVIDE ALL NECESSARY TEMPORARY BRACING, SHORING, GUYING OR OTHER MEANS TO AVOID EXCESSIVE
STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION.
DESIGN SHEET PILING AREA
SHEET PILING REQUIREMENTS
MINIMUM SECTION MODULUS OF 34.6 CUBIC INCHES PER FOOT OF WALL.
MINIMUM GRADE OF STEEL IS 36 KSI.
MINIMUM MOMENT OF INERTIA OF 305 INCHES ^ 4 PER FOOT OF WALL.
ALL SHEETING SHALL MEET ASTM A-328, A-572 GR50 OR A-690.
APPROVED PRODUCTS
SHORELINE STEEL SZ-14.5
JD FIELDS PZC 12
GERDAU AMERISTEEL PZC 13, PZC 12
NUCOR SKYLINE SCZ 14
OTHER SHEETING MAY BE ALLOWED WITH PRIOR APPROVAL OF ENGINEER. ALL
MATERIALS ARE BASED ON MINIMUM COVERAGE AND FURTHER SIZING WILL
NEED TO BE DONE. SIZING IS BASED ON INSTALLED STRENGTH. CONTRACTOR
SHALL CONSIDER CONSTRUCTIBILITY WHEN SELECTING A SHEET PILE SIZE.
BOLT DETAIL
NOT TO SCALE
GROUTED RIPRAPMETAL SHEET PILING
GEOTEXTILE FABRIC
GROUTED RIPRAP DETAIL
NOT TO SCALE
FLOW
DIRECTION
1" BOLT W/ (2) WASHERS
SHEET PILE
SPLICE
SHEET PILE
SPLICE
SHEET PILE
C10X15.3
WALER CONT.
SHEET PILE
C10X15.3 WALER CONT.
1" BOLT W/ (2)
WASHERS
NOTE: 1 BOLT TO BE PLACED ON EACH SIDE OF SPLICE
WALER BOLT PLACEMENT
NOT TO SCALE
C10X15.3 WALER
CONTINUOUS
ENTIRE FINISHED SURFACE
SHALL BE 0.2' LOWER THAN
TOP OF WEIR
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT.
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 6/
1/
:0 8:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.03
CPDT INSTALLATION DETAILS
FLAT BOTTOM TRENCH INSTALLATION
FILL TRENCH TO 6" ABOVE TOP OF PIPE WITH CRUSHED STONE OR GRAVEL
MEETING THE REQUIREMENTS IN TABLE 2. BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE PIPE INSTALLATION.
PREFFERED TRENCH INSTALLATION BOTTOM
CORRUGATED POLYETHYLENE DRAINAGE TUBING
MATERIAL & INSTALLATION NOTES
NOT TO SCALE
SOURCE: ASTM F449
TRAPEZOIDAL GROOVE, "V" GROOVE, & CIRCULAR GROOVE
NOT TO SCALE
SOURCE: ASTM F449
6" MIN FOR
OPEN TRENCH
INSTALLATION
R
6" M
IN
A B G
0.
5R
0.
R
TRENCH WIDTH MEASURED
AT TOP OF PIPE
90° "V" GROOVE
90°
THE CIRCULAR GROOVE SHALL BE A
MINIMUM 0.35R DEEP AND SHALL
MATCH THE OUTSIDE CURVE
SHAPE OF THE DEFLECTED CPDT.
THE TRAPEZOIDAL GROOVE SHALL
BE SHAPED AND ADJUSTED SUCH
THAT POINTS A, B, & C WILL TOUCH
THE UNDEFLECTED CPDT FOR EACH
SIZE INSTALLED.
TRAPEZOIDAL GROOVE
CIRCULAR GROOVE
UNDISTURBED SOIL
UNDISTURBED SOIL
TRENCH WIDTH MEASURED
AT TOP OF PIPE
4" M
IN
SEE TABLE 2 FOR
BEDDING MATERIAL
NOTE: THIS IS AN ALLOWED ALTERNATIVE INSTALLATION FOR CPDT
1. ALL CPDT AND CONNECTORS FURNISHED SHALL BE IN COMPLIANCE WITH MATERIAL STANDARDS ASTM F405 AND F667, AS
APPLICABLE, AND SHALL BE CLASSIFIED AS HEAVY-DUTY UNDER THOSE STANDARDS.
2. EXCEPT MODIFIED HEREIN OR OTHERWISE APPROVED BY ENGINEER, ALL CPDT SHALL BE INSTALLED IN COMPLIANCE WITH THE
ASTM 449 STANDARD PRACTICE.
3. FOR PIPES 6” DIAMETER AND SMALLER A 90° V GROOVE BOTTOM MAY BE USED, FOR ALL LARGER PIPE A TRAPEZOIDAL BOTTOM OR A CIRCULAR BOTTOM CONFORMING TO THE OUTSIDE DIAMETER OF THE PIPE SHALL BE USED. PRIOR TO THE INSTALLATION OF CPDT, CONTRACTOR MUST PROVE TO ENGINEER THAT THE INSTALLATION REQUIREMENTS, INCLUDING THE
SHAPE OF THE TRENCH BOTTOM, WILL BE ACCOMPLISHED.
4. WHERE TRENCH BOTTOM IS IN FIRM UNDISTURBED SOIL, SHAPE TRENCH BASE GROOVE. WHERE EXCESS CUT OCCURS, OVEREXCAVATE AND PLACE MINIMUM THREE (3) INCH THICK, GRAVELLY SAND BEDDING TO RESTORE GRADE. THIS BEDDING SHALL MEET THAT REQUIRED FOR TRENCH INSTALLATION TYPE 3 ON PLAN SHEET B.02. THIS MATERIAL AND WORK SHALL BE INCIDENTAL TO THE INSTALLATION OF THE PIPE. CONTRACTOR MAY SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING
MATERIAL.
5. NATIVE SOILS MAY BE USED AS BACKFILL MATERIAL UNLESS UNSTABLE TRENCH CONDITIONS PREVENT THE TRENCH BOTTOM HOLDING THE SHAPED GROOVE. IF TRENCH BOTTOM WILL NOT HOLD GROOVE SHAPE CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY. A FLAT BOTTOM TRENCH INSTALLATION WILL THEN BE ASSUMED. THE REQUIRED BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE INSTALLATION OF THE PIPE.
6. MINIMUM TRENCH WIDTH IS PIPE OUTSIDE DIAMETER PLUS FOUR (4) INCHES FOR PLOWED INSTALLATION AND PIPE OUTSIDE
DIAMETER PLUS TWELVE (12) INCHES FOR OPEN TRENCH INSTALLATION.
7. ALL LATERAL CONNECTIONS, ELBOWS, TEES, ALIGNMENT CURVES, START HOLES AND ALL PORTIONS OF THE TRENCH NOT MEETING THE GROOVED TRENCH INSTALLATION REQUIREMENTS SHALL BE FILLED TO A MINIMUM OF SIX (6) INCH COVER OVER THE PIPE WITH GRADED CRUSHED STONE OR GRAVEL AS SHOWN ON TABLE 2 OF THIS SHEET. BEDDING MATERIAL SHALL BE
INCIDENTAL TO THE INSTALLATION OF THE PIPE.
8. MANUFACTURER'S ENDCAPS SHALL BE INSTALLED AT THE TERMINATION OF EACH LINE UNLESS A CONNECTION TO AN EXISTING
DRAIN IS MADE.
9. WITH THE INSTALLATION OF THE FIRST REACH OF CPDT ON THE PROJECT, CONTRACTOR IS REQUIRED TO WORK WITH THE
ENGINEER TO CHECK AND CONFIRM THAT THE PIPE STRETCH, IF ANY, DOES NOT EXCEED 5%.
10. ALIGNMENT TURNS MAYBE MADE USING EITHER A MANUFACTURED FITTING OR CURVING THE LINE WITH A 25' MINIMUM
RADIUS.
R25'
PI
X °
PT
PT
Table 1 Maximum Allowable Buried Depth to Flowline of CPDT
Nominal Pipe Diameter (IN)
Pipe Quality
(ASTM)
Trench Width at Top of the Pipe (FT)
12" 18" 24" 30" or Greater
Standard 13 7 5.5 5
Heavy-duty Any 10 7 6
Standard 10 7 5.5 5
Heavy-duty Any 9.5 6.5 6
Standard 10 7 5.5 5
Heavy-duty Any 10 7 6
10 Heavy-duty ... 9 7 6 12 Heavy-duty ... 9 7 6 15 Heavy-duty ... ... 7 6
Table 2 Acceptable Bedding Material and Compaction Requirements
Description Percentage Passing Sieve Sizes Minimum
Standard Density (%)
Maximum Compaction Layer Height
(IN.)1" 3/4" No. 4
Crushed Stone Crushed Gravel* 100% > 95% < 5% Dumped 18
* Class 1 Bedding Material Per SUDAS 3010.202A is an Allowable Substitute
DEGREES Δ DELTA
20° 4.41 30° 6.7 45° 10.36 60° 14.43 70° 17.51 80° 20.98 90° 25 ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 6/
1/
:0 8:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.04
RCP INSTALLATION DETAILS
TRENCH INSTALLATION TYPE 3
COMPLETELY FILL
HAUNCH AREA WITH
GRAVELLY SAND
COMPACT TO 85%
STANDARD PROCTOR
DENSITY.
Do
LOOSELY PLACED UNCOMPACTED
GRAVELLY SAND BEDDING
Do/3
3" MIN.
PIPE SPRINGLINE
GRAVELLY SAND BEDDING SHALL BE CONSISTENT WITH THE GRADATION AND
OTHER CHARACTERISTICS OF STANDARD AASHTO A1 OR A3 SOIL. A
REPRESENTATIVE SAMPLE OF THE MATERIAL AND A GRADATION REPORT OR
SUPPLIER'S CERTIFICATION OF COMPLIANCE SHALL BE SUBMITTED TO THE
ENGINEER FOR APPROVAL PRIOR TO DELIVERY TO SITE. SEE SOIL DATA IN
APPENDIX OF SPECIFICATIONS BOOKLET.
6" TYP
0" MIN MEASURE POINT FOR
MAXIMUM TRENCH WIDTH
TOP OF
PIPE
CRUSHED ROCK MEETING THE GRADATION OF SUDAS CLASS I BEDDING
MATERAL, SPECIFICATION SECTION 3010.2.02.A, MAY BE SUBSTITUTED FOR
THE SAND OR CLAY HAUNCH BACKFILL MATERIAL. NO COMPACTION WILL BE
REQUIRED FOR THE CRUSHED ROCK BEDDING AND BACKFILL. MATERIAL
COSTS SHALL BE INCIDENTAL TO PIPE INSTALLATION.
MODIFIED TRENCH INSTALLATION TYPE 4
COMPLETELY FILL HAUNCH
AREA WITH NON-SATURATED
SILTY CLAY OR CLAY SOIL.
COMPACT TO 85% STANDARD
PROCTOR DENSITY. THERE
ARE NO SPECIFIED MOISTURE
LIMITS.
Do
WHERE TRENCH BOTTOM IN FIRM UNDISTURBED SOIL,
SHAPE TRENCH BASE GROOVE TO MATCH MINIMUM
1/6 OF THE OUTER CIRCUMFERENCE OF THE PIPE.
WHERE THE SHAPED GROOVE CANNOT BE
CONSTRUCTED INTO UNDISTURBED GROUND OR
WHERE EXCESS CUT OCCURS OVER EXCAVATE AND
PLACE MINIMUM 3-INCH THICK COMPACTED GRAVELLY
SAND BEDDING TO RESTORE GRADE SUCH THAT 1/6 OR
MORE OF THE OUTER CIRCUMFERENCE OF THE PIPE IS
BEDDED. THIS MATERIAL AND WORK IS SUBSIDIARY TO
THE INSTALLATION OF THE PIPE. CONTRACTOR MAY
SUBSTITUTE PIPE BEDDING ROCK AS THE BEDDING
MATERIAL. IT ALSO IS SUBSIDIARY.
PIPE SPRINGLINE
6" TYP
0" MIN MEASURE POINT FOR
MAXIMUM TRENCH WIDTH
TOP OF
PIPE
MINIMUM TRENCH WIDTH SHALL BE OUTSIDE DIAMETER OF PIPE PLUS 12" OR
THAT WIDTH WHICH IS REQUIRED FOR COMPACTION, WHICHEVER IS GREATER
WHERE FIRM BASE IS NOT
ENCOUNTERED. OVER
EXCAVATE AS DIRECTED BY
ENGINEER. PLACE CRADLING
ROCK AND BED PIPE IN IT
SUCH THAT 1/6 OR MORE OF
THE OUTER CIRCUMFERENCE
OF THE PIPE IS SUPPORTED.
THIS ROCK IS PAID FOR UNDER
A SEPARATE BID ITEM.
THE CONTRACTOR IS SOLEY RESPONSIBLE FOR THE INSTALLATION OF ALL PIPE ACCORDING TO PLAN REQUIREMENTS.
THE CONTRACTOR'S PARTICIPATION IN AND COMPLIANCE WITH THE FOLLOWING PROCEDURE IS REQUIRED AND WILL
ALLOW FOR FEWER SOIL DENSITY TESTS TO ENSURE PROPER PIPE INSTALLATION.
STEP 1
BEFORE COMMENCING PIPE INSTALLATION, STANDARD SOIL PROCTOR DENSITY TEST RESULTS OF REPRESENTATIVE SAMPLE(S) OF PIPE HAUNCH FILL SHALL BE PROVIDED BY AN INDEPENDENT QUALIFIED SOILS TESTING LAB. THE SELECTION OF THE SAMPLE(S) WILL BE MADE BY THE ENGINEER AND CONTRACTOR (WHEN SPECIFIED).
STEP 2
CONTRACTOR MAY BEGIN EXCAVATING THE MODIFIED TYPE 4 TRENCH
WITH THE REQUIRED SHAPED BOTTOM GROOVE AND PLACE SEVERAL PIPE SECTIONS ONLY WHEN BOTH ENGINEER AND
TESTING LAB TECHNICIAN ARE PRESENT
CONTRACTOR SHALL DEMONSTRATE THE INTENDED METHODS FOR COMPACTING THE FILL FOR THE PIPE HAUNCH AREAS. SOIL DENSITY TESTS SHALL BE TAKEN AT LOCATIONS DESIGNATED BY THE ENGINEER TO CONFIRM THAT THE INTEDNED METHODS FOR FILL AND COMPACTION OF THE PIPE HAUNCH AREAS SATIFIES THE PLAN REQUIREMENTS.
CONTRACTOR SHALL MODIFIY THE INSTALLATION METHODS AND REPEAT STEP 2 UNTIL ACCEPTABLE TESTS RESULTS ARE
ACHIEVED.
STEP 3
CONTRACTOR MAY INSTALL THE NEXT SEVERAL HUNDRED FEET OF PIPE. ENGINEER SHALL DESIGNATE SEVERAL LOCATIONS (APPROXIMATELY 10% OF THE INSTALLED LENGTH) WHERE CONTRACTOR SHALL LEAVE THE PIPE UNBLINDED FOR FURTHER DENSITY TESTS OF THE HAUNCH FILL AREA. ALL DENSITY TESTS MUST MEET PLAN REQUIREMENTS BEFORE
WORK MAY PROCEED FURTHER.
IF DENSITY TESTING DATA CONFIRMS TO THE SATISFACTION OF THE ENGINEER THAT THE CONTRACTOR'S INSTALLATION METHOD WILL PRODUCE CONSISTENT COMPLIANCE WITH PLAN REQUIREMENTS, CONTRACTOR MAY CONTINUE INSTALLATION OF THE PIPE WITH NO ADDITIONAL TESTING REQUIRED. IF NOT, STEPS 2 AND 3 SHALL BE REPEATED UNTIL A RELIABLE, SUCCESSFUL METHOD OF PIPE INSTALLATION THAT PRODUCES SATISFACTORY RESULTS IS ESTABLISHED.
TRENCH WALLS
PLUG DOWNSTREAM
TILE WITH PLASTIC END
PLUG, CONCRETE, OR
AS OTHERWISE
ALLOWED.FLOW FLOW
CUT AND SHAPE END OF P.E.
TILE TO FIT FLUSH WITH INSIDE
OF CONCRETE TILE. GROUT
CONNECTION
FILL TRENCH TO P.E. SPRINGLINE WITH COMPACTED CRUSHED
STONE. WHERE COVER EXCEEDS 8 FEET, COVER CONNECTION
AND EXPOSED P.E. WITH 12 INCHES OF CRUSHED STONE
BEDDING COMPLYING WITH SUDAS SPECIFICATION SECTION
3010.301. BUCKET PRESS & COMPACT EARTH FILL UNIFORMLY
ON BOTH SIDES OF STONE TO RESIST LATERAL MOVEMENT OF
THE STONE.
CONCRETE COLLAR EXCEPTION
CONNECTIONS TO THE PIPE AT BOTH ENDS MAY BE MADE
WITH A MANUFACTURED POLYETHYLENE INTERNAL SNAP
COUPLER INSERTED FULLY INTO THE PIPE. CONCRETE COLLARS
NOT REQUIRED WITH POSITIVE LOCKED CONNECTION OR
WHERE COMPACTED CRUSHED ROCK FULLY SURROUNDS THE
CONNECTION. GAPS AT THE CONNECTIONS SHALL BE COVERED
WITH ENGINEERING FABRIC WRAPPED AROUND THE JOINT.
INSERTA TEE WILL BE CONSIDERED AS ALTERNATE
CONNECTION AT NEW MAIN WITH ENGINEERS PRIOR
APPROVAL AND INSTALLATION PER MANUFACTURERS
RECOMMENDATION.
TYPICAL FIELD TILE CONNECTION
FOR FIELD TILE UP TO 10" DIAMETER
CO
VE
R
USE NON-PERFORATED
CORRUGATED P.E. DRAIN TILE
UNDISTURBED
SOIL
SLIDE CORRUGATED P.E. TILE A
MINIMUM OF 6" OVER END OF
EXISTING TILE. ENCASE JOINT (IF
NOT TIGHT FITTING) IN P.C.
CONCRETE COLLAR, AS SHOWN.
FIELD TILE
A
A
PIPE HAUNCH FILL AND COMPACTION METHOD
PLAN REQUIREMENTS COMPLIANCE VERIFICATION
12"
6"
HAND SHAPE TRENCH FOR P.E.
TILE TO INSURE UNDISTURBED
SOIL SUPPORT LOWER 1/2 OF
TILE PERIMETER OR BED ON
CRUSHED STONE FILL AND
THOROUGHLY TAMP SOIL
ENVELOPE
SECTION A-A
TOP OF SOIL
ENVELOPE
UNDISTURBED
SOIL
CONTRACTOR IS REQUIRED TO PROPERLY AND ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE
INSTALLATION WORKERS ON THE PROPER INSTALLATION METHOD.
STEP 4A
SOIL OR TRENCH CONDITION CHANGES
TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS UNDER THE CHANGED CONDITIONS, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH
3. THE WORK AND COSTS OF THE FIRST TWO REVERIFICATIONS IS SUBSIDIARY TO THE PIPE INSTALLATION. SUBSEQUENT
VERIFICATIONS WILL BE CONSIDERED EXTRA WORK.
STEP 4B
CONTRACTOR FAILS TO CONSISTENTLY PERFORM INSTALLATION METHOD OR INSTRUCT OTHER INSTALLERS
IF CONTRACTOR FAILS TO CONSISTENTLY PERFORM OR ADEQUATELY INSTRUCT SUBCONTRACTORS AND/OR SUBSEQUENT PIPE INSTALLATION WORKERS ON THE APPROVED INSTALLATION METHOD, ENGINEER MAY STOP WORK AND REQUIRE ADDITIONAL SOIL PROCTOR TESTS AND/OR SOIL DENSITY TESTS SIMILAR TO STEPS 1 THROUGH 3 TO VERIFY CONTRACTOR'S COMPLIANCE WITH PLAN REQUIREMENTS. THE WORK AND COSTS OF ALL VERIFICATIONS UNDER SUCH
CONDITIONS IS SUBSIDIARY TO THE PIPE INSTALLATION.
EXCEPTION
IF CONTRACTOR ELECTS TO SHAPE THE TRENCH BOTTOM SUCH THAT A MINIMUM OF 45% OF THE OUTER CIRCUMFERENCE OF THE PIPE IS FIRMLY BEDDED IN AND CONSISTENTLY SUPPORTED BY UNDISTURBED SOIL, PIPE HAUNCH FILL COMPACTION TESTING WILL NOT BE REQUIRED. THE CONTRACTOR IS REQUIRED TO COMPLY WITH A PROPER INSTALLATION METHOD AND TO FULLY COMPLY WITH THE REQUIREMENTS OF THE VERIFICATION OUTLINED
ABOVE FOR ALL SITUATIONS WHERE THIS EXCEPTION IS NOT MET.
NOT TO SCALE
SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION
CONCRETE PIPE DESIGN MANUAL
NOT TO SCALE
SOURCE: AMERICAN CONCRETE PIPE ASSOCIATION
CONCRETE PIPE DESIGN MANUAL
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
B0
1.
dw g 6/
1/
:0 8:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
B.05
MISCELLANEOUS DETAILS
2" DIA. PERFORATIONS
SPACED 5" O.C.
SURROUND WITH CLASS E RIP RAP TO 3 FT HEIGHT
1.5 TN
12" RCP DRAWDOWN PIPE
CONCRETE COLLAR
AT JOINT
24" DIA. DUAL-WALL
HDPE RISER PIPE
24" AGRI DRAIN HEAVY DUTY BAR
GUARD OR APPROVED EQUAL
NWL
EXISTING GROUND
SURFACE
36" DIAMETER x 12" THICK
REINFORCED CONCRETE PAD
24" AGRI DRAIN HEAVY DUTY BAR
GUARD OR APPROVED EQUAL
12" RCP DRAWDOWN PIPE
CONCRETE COLLAR
AT JOINT
OUTLET RISER DETAIL
ALTERNATIVE 1: RCP ANTI-SEEP COLLAR
NOT TO SCALE
1/2" X 2" SLOTTED HOLES
FOR 3/8" DIA. BOLTS
CONTINUOUS WELD
BETWEEN BAND
AND COLLAR.
3'
3'
10'
SLOTTED HOLES
@ 8" O.C.
CONTINUOUS WELD
BETWEEN BAND
AND COLLAR.
BAND
BOTTOM OF BAND
2" 2"
BAND
A
A
12"TOP OF BAND
BOTTOM OF COLLAR
CORRUGATED METAL SHEET WELDED
TO CENTER OF SMOOTH METAL
BAND WITH MASTIC APPLIED FOR
SEALANT AROUND THE PIPE.
OPTIONAL SUBSTITUTE -
CAST-IN-PLACE CONCRETE BAND.
ANTI-SEEP COLLAR DETAILS
ALTERNATIVE 2: COMPOSITE BENTONITE AGGREGATE COLLAR
NOT TO SCALE
12" ID
RCP
TRENCH WIDTH (SEE PLANS)
5 FT MIN. COLLAR WIDTH
FT
C O
LL
AR
TH
IC
KN
ES
S
NOTES:
1. COMPOSITE BENTONITE AGGREGATE
(CBA) SHALL BE AQUABLOK OR
APPROVED EQUAL.
2. COLLAR SHALL EXTEND 1.75 FT BELOW
BOTTOM OF PIPE AND 1.75 FT ABOVE
TOP OF PIPE
3. COLLAR SHALL BE A MINIMUM OF 5 FT
WIDE AND EXTEND A MINIMUM OF 6"
BEYOND EDGE OF TRENCH
4. NO COMPACTION OF CBA IS
REQUIRED.
5. EXCAVATE AND BACKFILL THE
REMAINDER OF THE TRENCH AS
NOTED IN THE PLANS.
CORRUGATED METAL SHEET
GALVANIZED STEEL
PREFABRICATED HPDE ANTI-SEEP
COLLARS ARE AN ALLOWED ALTERNATIVE.
BAND
ol to n
M en k, In c.
6, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
C0
1.
dw g 6/
1/
:0 9:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
C.01
ESTIMATED QUANTITIES
Bid Item Sub-Item Description
Specifications Plan No.
Estimated Quantities No. Page Quantity Unit
1 - Site Stripping & Preparation IA CS-001 3-4 A.02 1 LS 2 - Crop Damage IA CS-001 3-4 - 0 AC 3 - Structure & Channel Seeding IA CS-006 7-10 K.01 2.1 AC 4 - Buffer Seeding IA CS-006 7-10 K.01 13.1 AC 5 - Mobilization and Demobilization IA CS-008 11-12 - 1 LS 6 - Drain Tile Investigation and Removal
1 Tile Removal IA CS-009 14-17 A.03 8 HR 2 Tile Abandonment IA CS-009 14-17 A.03 1 LS
7 - Steel Sheet Piling IA CS-013 20-21 B.02, D.02 2523 SF 8 - Excavation (General) IA CS-021 22-24 D.01 10944 CY 9 - Earthfill (General) IA CS-023 25-28 D.01, D.05 1210 CY
10 - Earthfill (General Dam) IA CS-023 25-28 D.02 2283 CY 11 - Earthfill (Dam Core) IA CS-023 25-28 D.02 767 CY 12 - Drainfill, Fine IA CS-024 29-31 D.02 23 CY 13 - Topsoil Strip, Salvage, and Respread IA CS-026 32-33 D.01 3073 CY 14 - 12" Dia. Reinforced Concrete Pipe IA CS-031 34-40 D.02 16 LF 15 - 12" Dia. Reinforced Concrete Pipe (Gasketed) IA CS-031 34-40 M.02 136 LF 16 - 30" Dia. Reinforced Concrete Pipe IA CS-031 34-40 M.01 805 LF 17 - Modified SW-402 Water Control Structure IA CS-031 34-40 B.01, M.02 1 EA 18 - 12" Dia. Reinforced Concrete Apron, Footing, Bar Guard IA CS-031 34-40 M.02 1 EA 19 - 30" Dia. Reinforced Concrete Apron, Footing, Bar Guard IA CS-031 34-40 M.01 1 EA 20 - 6" Dia. Corrugated HDPE Pipe (Single-Wall; Perforated) IA CS-046 41-44 D.02, M.02 335 LF 21 - 6" Dia. Corrugated HDPE Pipe (Single-Wall; Non-Perforated) IA CS-046 41-44 M.02 205 LF 22 - Stoplog Storage Structure IA CS-046 41-44 B.01 1 EA 23 - Outlet Riser Structure IA CS-046 41-44 B.05, M.02 1 EA 24 - Anti-Seep Collars IA CS-051 45-47 B.05, M.02 2 EA 25 - Rip Rap (Class E) IA CS-061 48-49 D.03, M.01-M.02 383 TN 26 - Grout for Rip Rap IA CS-062 50-52 D.04 46 CY
56 13
62 13
62 13
DIVERSION BERMS
TOP ELEV. 1359.50
4:1 SIDE SLOPES
FILL TO 1357.50
FILL TO 1357.50
EXCAVATE TO 1359.00
10 FT WIDE EMBANKMENT
TOP ELEV. 1364.50
3:1 SIDE SLOPES
GRADE OUT TO EXISTING
SURFACE AT 4:1 SLOPE
GRADE OUT TO EXISTING
SURFACE AT 4:1 SLOPE
GRADE OUT TO EXISTING
SURFACE AT 4:1 SLOPE
GRADE OUT TO EXISTING
SURFACE AT 4:1 SLOPE
CONSTRUCT 10 FT WIDE
WAVE BERM ADJACENT
TO NORMAL POOL
EXCAVATE TO 1359.00
EXCAVATE TO 1359.00
35 FT WIDE AUXILIARY SPILLWAY
CREST ELEV. 1362.75
3:1 SIDE SLOPES
10 FT x 20 FT STILLING BASIN
BOTTOM ELEV. 1350.00
2.5:1 SIDE SLOPES
10 FT WIDE OUTLET CHANNEL
3:1 SIDE SLOPES
8 FT WIDE COVER BERM
TOP ELEV. 1367.00
6:1 SIDE SLOPES
40 FT x 40 FT SEDIMENT BASIN
BOTTOM ELEV. 1356.00
2.5:1 SIDE SLOPES
NORMAL POOL (1360.00)
DEEP WATER AREA (<1357.00)
100-YEAR HWL (1363.49)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1359.00
FILL TO 1357.50
MINIMUM 6" TOPSOIL LAYER
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
D0
1.
dw g 6/
1/
:0 9:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
D.01
GRADING OVERVIEW
R
FEETSCALE
0 50 100
HORZ.
0+00 1+00 2+00 3+00 4+00 5+00
.5
.4
.1
.7
.0
.3
.7
.6
.4
.2
.5
.2
.7
.9
.8
.2
.4
.0
.0
.1
.3
.4
.4
.5
.5
.2
.2
.8
.8
.5
.5
.5
.5
.5
.5
.5
144' - 6" HDPE @ ???
144 LF - 6" PERF. HDPE
3:1 3:
2.5:1
2.
5:
OVERBUILD
ELEV: 1364.71
OVERBUILD
ELEV: 1364.85
OVERBUILD
ELEV: 1365.00
OVERBUILD
ELEV: 1364.99
OVERBUILD
ELEV: 1364.84
OVERBUILD
ELEV: 1364.61
0.00%
3:1 3:
0.00%0.00%
STA: 0+59.96
EL: 1364.50
STA: 0+63.18
EL: 1364.50
STA: 0+69.22
EL: 1362.50
STA: 0+94.59
EL: 1362.50
STA: 1+00.79
EL: 1364.50 STA: 1+77.49
EL: 1364.50
STA: 1+90.99
EL: 1360.00
STA: 2+39.99
EL: 1360.00
STA: 2+53.49
EL: 1364.50
STA: 4+38.24
EL: 1364.50
49' WEIR
EXISTING SURFACE
35 FT AUXILIARY SPILLWAY
ELEV. 1362.75 TOE DRAIN
CONNECT TOE DRAIN
TO DRAWDOWN PIPE
BOTTOM OF CORE TRENCH
5 FT BELOW EXISTING SURFACE
WATER CONTROL STRUCTURE
NWL = 1360.00
DEEP WATER AREA ( > 3 FT DEEP)
TOE DRAIN
DAYLIGHT ELEV. 1362.00
16 LF 12" RCP
STILLING BASIN
BOTTOM ELEV. 1350.00
7.22%
5.42%
16' - 12" RCP @ 5.42%
16 LF - 12" RCP
@ 5.42%
5.56%
3.07%
81' - 6" HDPE @ 7.22%
81 LF - 6" PERF. HDPE
@ 7.22%09
0+00 1+00 2+00 3+00 4+00 5+00
BP
: 0
+0 0.
EP
: 5
+0 0.
136113 621363
13641366
55 13
60 13 651356
1357 13
55 13
MODIFIED SW-402 WATER CONTROL STRUCTURE
TOE DRAIN
TOE DRAIN
OUTLET RISER STRUCTURE
35 FT AUXILIARY SPILLWAY
CONNECT TOE DRAIN TO DRAWDOWN PIPE
DAYLIGHT TOE DRAIN TO STILLING BASIN
ELEV. 1352.00
DRAWDOWN PIPE
10 FT WIDE WAVE BERM
ADJACENT TO NORMAL POOL
NORMAL POOL (1360.00)
DEEP WATER AREA (<1357.00)
100-YEAR HWL (1363.49)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1359.00
FILL TO 1357.50
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
D0
2.
dw g 6/
1/
:0 9:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. D.02
PLAN & PROFILE - EMBANKMENT
TOE DRAIN CROSS SECTION
1 FT
FT
6" PERFORATED DRAIN TILE
FINE DRAINFILL ENVELOPE
(MINIMUM EXTENTS)
3"
10 FT WIDE TOP (4.5 FT ABOVE NWL)
10 FT WAVE BERM (AT NWL)
5 FT MIN. CORE TRENCH WIDTH
(TOP AND BOTTOM)
NORMAL WATER LEVEL
TOP OF CORE TRENCH
AT NWL
1:1 MAX SLOPES
3:1
3:1
EMBANKMENT CROSS SECTION
NOTE: ONLY BUILD WAVE
BERM ADJACENT TO POOL BOTTOM OF CORE TRENCH
5 FT BELOW EXISTING GRADE
-0+50 0+00 1+00 2+00 2+75
.0
.5
.8
.0
.5
.6
.5
STA: 0+81.50
EL: 1360.00
STA: 1+00.00
EL: 1360.00
ST
A:
+0
0.
EL
: 1
0.
STA: 1+20.00
EL: 1350.00
STA: 1+24.50
EL: 1351.50
STA: 1+29.50
EL: 1351.50 STA: 1+84.30
EL: 1349.17
0.00%
3:
1 -4.25%
0.00%
0.00%
MINIMUM SHEET PILE
COVERAGE LIMIT
EXISTING SURFACE
10 FT WIDE WAVE BERM
NWL = 1360.00
10 FT WIDE EMBANKMENT
TOP ELEV. 1364.50
DEEP WATER AREA
( > 3 FT DEEP)
TEMPORARY SHEET PILE
CONSTRUCTION BERM
PLACE RIP RAP 1.5 FT THICK
(GROUTED AREA SHADED)
OUTLET CHANNEL
EXISTING 6 FT x 6 FT BOX CULVERT
INVERT ELEV. 1349.25
0+00 1+00 2+00
BP
: 0
+0 0.
EP
: 2
+0 0.
62 13
GROUTED RIP RAP
UPSTREAM OF WEIR
18.3 CY GROUT
65.0 TONS RIP RAP
RIP RAP DOWNSTREAM OF WEIR
296.1 TONS
GROUT DOWNSTREAM OF WEIR
27.5 CY
GROUTED AREA SHADED
10' 10'
.5
29.5' EXISTING 6 FT x 6 FT
CONCRETE BOX CULVERT
INVERT ELEV. 1349.25
0+50 1+00 2+00 3+00 3+75
.1
.7
.0
.3
.7
.6
.4
.2
.5
.2
.7
.9
.8
.2
.4
.4
.5
.5
.2
.2
.8
.8
.5
.5
.5
.5
.5
49' WEIR
STA: 1+74.24
EL: 1364.50
STA: 2+10.49
EL: 1350.00
STA: 2+20.49
EL: 1350.00
STA: 2+56.74
EL: 1364.50
STA: 0+59.96
EL: 1364.50
STA: 0+63.18
EL: 1364.50
STA: 0+69.22
EL: 1362.50
STA: 0+94.59
EL: 1362.50
STA: 1+00.79
EL: 1364.50
STA: 1+77.49
EL: 1364.50
STA: 1+90.99
EL: 1360.00
STA: 2+39.99
EL: 1360.00
STA: 2+53.49
EL: 1364.50
UPSTREAM SPILLWAY SURFACE
EXISTING SURFACE
STILLING BASIN
10 FT BOTTOM WIDTH
PLACE RIP RAP IN 1.5 FT THICK LAYER CEMENTED
WITH GROUT UNDERLAIN BY GEOTEXTILE FABRIC
MINIMUM SHEET PILE
COVERAGE LIMIT
TOP OF EMBANKMENT
1+00 2+00 3+00 4+00
136113 621363
13641366
55 13
601356
1357 13
PRESERVE EXISTING 6 FT x 6 FT
CONCRETE BOX CULVERT
49 FT WEIR
55 13
OUTLET CHANNEL
10 FT BOTTOM WIDTH
3:1 SIDE SLOPES
20 FT STILLING BASIN
10 FT BOTTOM WIDTH
2.5:1 SIDE SLOPES
NORMAL POOL (1360.00)
DEEP WATER AREA (<1357.00)
100-YEAR HWL (1363.49)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1359.00
FILL TO 1357.50
STRUCTURE SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
D0
2.
dw g 6/
1/
:0 9:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. D.03
PLAN & PROFILE - STILLING BASIN & OUTLET CHANNEL
R
STILLING BASIN PROFILE STILLING BASIN CROSS-SECTION
-3+00 -2+00 -1+00 0+00 1+00 2+00 3+00 4+00 4+50
.4
.9
.6
.9
.2
.5
.2
.5
.7
.9
.4
.0
.7
.7
.3
.8
.3
.8
EXISTING SURFACE
AUXILIARY SPILLWAY
35 FT WIDTH
TOP OF EMBANKMENT
10 FT WIDTH
NWL = 1360.00
EXCAVATED POOL
0.00%
-5.90%
ST
A:
+8
7.
EL
: 1
2.
ST
A:
+0
8.
EL
: 1
2.
ST
A:
+3
3.
EL
: 1
5.
0+
1+00
2+00
2+50
BP: 0+00.00
PC: 0+43.16
PT: 1+54.22
PI: 1+58.16
EP: 2+50.00
NORMAL POOL (1360.00)
DEEP WATER AREA (<1357.00)
100-YEAR HWL (1363.49)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1359.00
FILL TO 1357.50
STRUCTURE SEEDING
LEGEND
35 FT BOTTOM
3:1 SIDES
TOP OF EMBANKMENT
EXISTING
GROUND
AUXILIARY SPILLWAY SECTION THROUGH EMBANKMENT
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
D0
2.
dw g 6/
1/
:0 9:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. D.04
PLAN & PROFILE - AUXILIARY SPILLWAY
0+00 1+00 2+00 3+00 3+25
.1
.6
.7
.5
.7
.0
.4
.2
.0
.0
.0
.8
.8
.6
.0
.6
.6
.5
.6
.9
.3
.1
.0
.9
.0
.7
.7
.6
STA: 1+00.00
EL: 1358.99
STA: 2+60.00
EL: 1358.99
STA: 2+57.96
EL: 1359.50
STA: 1+02.04
EL: 1359.50
4:1
4:1
POOL EXCAVATION
ELEV. 1359.00
POOL EXCAVATION
ELEV. 1359.00
POOL FILL
ELEV. 1357.00
TOP OF DIVERSION BERM
ELEV. 1359.50 NWL = 1360.00
EXISTING SURFACE
0+00 1+00 2+00 3+00 3+25
BP
: 0
+0 0.
EP
: 3
+2 5.
136013621364
1360 1362 1364
13581358
NORMAL POOL (1360.00)
DEEP WATER AREA (<1357.00)
100-YEAR HWL (1363.49)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1359.00
FILL TO 1357.50
STRUCTURE SEEDING
LEGEND
0+00 1+00 2+00 3+00 3+25
BP
: 0
+0 0.
EP
: 3
+2 5.
0+00 1+00 2+00 3+00 3+25
.9
.6
.7
.0
.5
.6
.6
.0
.4
.2
.5
.5
.0
.2
.9
.6
.7
.0
.4
.6
.5
.0
.3
.1
.4
.5
.0
.1
STA: 1+20.00
EL: 1358.99
STA: 1+22.04
EL: 1359.50
STA: 2+07.96
EL: 1359.50
STA: 2+10.00
EL: 1358.99
4:1
4:1
POOL EXCAVATION
ELEV. 1359.00
POOL EXCAVATION
ELEV. 1359.00
TOP OF DIVERSION BERM
ELEV. 1359.50
NWL = 1360.00
EXISTING SURFACE
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
D0
3.
dw g 6/
1/
:0 9:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. D.05
PLAN & PROFILE - DIVERSION BERMS
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
D0
3.
dw g 6/
1/
:0 9:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
R
10 FT WIDE TOP
6" BELOW NWL
NORMAL WATER LEVEL
DIVERSION BERM CROSS SECTION
EXISTING/EXCAVATED
GROUND SURFACE
4:1 SIDE SLOPES
WEST DIVERSION BERM EAST DIVERSION BERM
SEEDING AREAS
BUFFER SEEDING 13.1 AC
STRUCTURE SEEDING 2.1 AC
SEED EMBANKMENT
STRUCTURE SEEDING
SEED OUTLET CHANNEL
STRUCTURE SEEDING
SEED AUXILIARY SPILLWAY
AND SURROUNDING AREA
STRUCTURE SEEDING
SEED WAVE BERM TO 1 FT
BELOW NORMAL POOL
STRUCTURE SEEDING
DO NOT SEED POOL OR
DIVERSION BERMS
SEED DISTURBED AREAS TO
1 FT BELOW NORMAL POOL
STRUCTURE SEEDING
SEED DISTURBED AREAS TO
1 FT BELOW NORMAL POOL
STRUCTURE SEEDING
SEED BUFFER AREA TO
EASEMENT BOUNDARY
BUFFER SEEDING
SEED BUFFER AREA TO
EASEMENT BOUNDARY
BUFFER SEEDING
SEED DISTURBED AREAS TO
1 FT BELOW NORMAL POOL
STRUCTURE SEEDING
SEED COVER BERM EXTENTS
STRUCTURE SEEDING
DO NOT SEED RIP RAP AREAS
62 13
60 13
64 13
66 13
NORMAL POOL (1360.00)
DEEP WATER AREA (<1357.00)
100-YEAR HWL (1363.49)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1359.00
FILL TO 1357.50
STRUCTURE SEEDING
BUFFER SEEDING
LEGEND
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
K0
1.
dw g 6/
1/
:1 0:
A
M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
K.01
SEEDING OVERVIEW
R
FEETSCALE
0 50 100
HORZ.
-1+25 -1+00 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 10+75
.1
.6
.5
.2
.7
.0
.2
.1
.0
.5
.8
.8
.9
.4
.6
.9
.2
.6
.1
.4
.6
.2
.2
.5
.8
.2
.7
.2
.4
.8
.3
.8
.2
.9
.0
.5
.2
.4
.4
.4
.4
.4
.4
.3
.3
.3
.3
.3
.3
.3
.2
.2
.2
.2
.2
.2
.1
.1
.1
.1
.1
.1
.1
.0
.0
.0
.0
.0
.0
-0.06%
STA: 0+29.70
EL: 1361.50
STA: 8+35.09
EL: 1361.00
ST
A
8+
" A
PR
O
N , F
O O
TI
N
G, B
AR
G
U
AR
D
DA
YL
IG
HT
E
LE
V.
1.
FL
IN
1.
(3
0" N
E)
ST
A
6+
° B
EN
D
CO
N
N
EC
T 6"
H
DP
E
TI
LE
TO
T
IL
E M
AI
N
R E-
LA
Y
FL
IN
1.
(3
0" N
E)
FL
O U
T
.1
(3 0"
S W
ST
A
0+
° B
EN
D
FL
IN
1.
(3
0" N
FL
O U
T
.4
(3 0"
S W
ST
A
0+
CO
N
N
EC
T
TO
E
XI
ST
IN
G
" T
IL
E M
AI
N
M
AT
CH
IN
VE
RT
S
° B
EN
D
FL
IN
1.
(1 8"
N E)
FL
O
U T
.5
(3
0" S
805' - 30" RCP @ 0.06%
805 LF - 30" RCP
@ 0.06% 3530
EXISTING SURFACE
EXISTING 18" TILE MAIN
FIELD LOCATE TIE-IN LOCATION
40 FT x 40 FT SEDIMENT BASIN
BOTTOM ELEV. 1256.00
8 FT WIDE COVER BERM
TOP ELEV. 1376.00
PROVIDE MIN. 3 FT COVER
NWL = 1360.00
STA: 8+03.09
EL: 1367.00
STA: 6+84.81
EL: 1367.00
2.5:1 2.
5:
6:1
EXCAVATED POOL
ELEV. 1359.00
DEEP WATER AREA
( > 3 FT DEEP)
NORMAL POOL (1360.00)
DEEP WATER AREA (<1357.00)
100-YEAR HWL (1363.49)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1359.00
FILL TO 1357.50
STRUCTURE SEEDING
LEGEND
>> >> >> >> >> >> >> >> >> >> >> >> >> >> >> >> >> >> >> >>0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 9+25
STA 0+30
CONNECT TO EXISTING
18" TILE MAIN
MATCH INVERTS
34° BEND
FL IN = 1361.50 (18" NE)
FL OUT = 1361.50 (30" S)
STA 0+50
30° BEND
FL IN = 1361.49 (30" N)
FL OUT = 1361.49 (30" SW)
STA 6+16
22° BEND
CONNECT 6" HDPE TILE
TO TILE MAIN RE-LAY
FL IN = 1361.14 (30" NE)
FL OUT = 1361.14 (30" SW)
STA 8+35
30" APRON, FOOTING, BAR GUARD
DAYLIGHT ELEV. 1361.00
FL IN = 1361.00 (30" NE)
BP
: 0
+0 0.
EP
: 9
+2 5.
PI
: 0
+2 9.
PI: 0+49.70
PI
: 6
+1 6.
6" HDPE TILE
SEE M.02
RIP RAP
20.1 TONS
15 FT x 17 FT
8 FT WIDE COVER BERM
TOP ELEV. 1367.00
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
M
.d w g
6/ 1/
:1
0:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
FEETSCALE
0 40 80
HORZ.
FEETSCALE
0 5 10
VERT. M.01
PLAN & PROFILE - TILE MAIN RE-LAY
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
M
.d w g
6/ 1/
:1
0:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
COVER BERM CROSS SECTION
8 FT
6:1
DD NO. 103 TILE MAIN CAPACITIES
EXISTING PROPOSED
DIAMETER (IN) = 18 30
SLOPE (%) = 0.60 0.06
CAPACITY (CFS) = 7.05 11.87
PR
O
VI
DE
M
IN
. 3 F
T
CO
VE
R
PROPOSED PIPE
R
EXISTING SURFACE
6:1
-0+50 0+00 1+00 2+00 2+50
.2
.9
.6
.4
.1
.8
.1
.1
.7
.2
.6
.8
.1
-1.87%
-3.04%
VPI: 0+35.00
EL: 1354.00
VP
I:
0+
.5
EL
: 1
3.
VPI: 1+70.85
EL: 1350.50
54' - 12" RCP @ 1.87%
54 LF
12" GASKETED RCP
@ 1.87% 8935
82' - 12" RCP @ 3.04%
82 LF
12" GASKETED RCP
@ 3.04% 71
ANTI-SEEP COLLAR
SEE B.05
EXISTING SURFACE
NWL = 1360.00
DEEP WATER
AREA ( < 3 FT)
EMBANKMENT
TOP ELEV. 1364.50
OUTLET CHANNEL
10 FT WAVE BERM
ST
A
0+
O U
TL
ET
R
IS
ER
S
TR
U
CT
U
RE
SE
E B.
TO
P
.0
FL
O
U T
.0
(1
2" W
ST
A
1+
" A
PR
O
N , F
O O
TI
N
G, B
AR
G
U
AR
D
DA
YL
IG
HT
E
LE
V.
0.
FL
IN
0.
(1
2" N
E)
M O
DI
FI
ED
S
W -4
(S
TA
+8 9)
W
AT
ER
C
O N
TR
O
L
ST
RU
CT
U
RE
SE
E
B.
TO
P
.5
FL
IN
3.
(1 2"
E
FL
O
U T
.0
(1
2" S
W
6 FT WIDE COVER BERM
PROVIDE MIN. 3 FT COVER
0+00 1+00 2+00 3+00 4+00
.5
.7
.7
.0
.5
.5
.8
.7
.7
.7
.6
.5
.8
.2
.1
.1
.5
.5
.7
.7
.9
.5
.4
.7
.6
.6
.7
.6
.5
.7
.2
.1
.1
.5
-0.11%
VPI: 0+45.00
EL: 1362.49
VPI: 3+60.00
EL: 1362.14
EXISTING SURFACE
ST
A
2+
° B
EN
D
FL
IN
2.
(6
" N E)
FL
O
U T
.2
(6
" S
TILE MAIN RE-LAY
30" RCP
MATCH PIPE CENTERLINES
ST
A
6+
CO
N
N
EC
T
TO
0"
R
CP
T
IL
E M
AI
N
M
AT
CH
P
IP
E
CE
N
TE
RL
IN
ES
FL
IN
2.
(6
" N
FL
IN
1.
(3
0" N
E)
FL
O U
T
.1
(3 0"
S W
110' - 6" HDPE @ 0.11%
110 LF - 6" PERF. HDPE
@ 0.11% 5545
205' - 6" HDPE @ 0.11%
205 LF - 6" NON-PERF. HDPE
@ 0.13% 60
NOTE: THIS TILE INSTALLATION SHALL INCLUDE
PERFORATED HDPE OUTSIDE OF EASEMENT
BOUNDARY, AND NON-PERFORATED HDPE
INSIDE THE EASEMENT BOUNDARY.
0+00
1+00
2+00
BP
: 0
+0 0.
PI
: 0
+8 8.
EP
: 2
+0 0.
RIP RAP
1.5 TONS
SEE B.05
54 13
56 13
64 13
CONNECT TOE DRAIN
TO DRAWDOWN PIPE
STA 0+35
OUTLET RISER STRUCTURE
SEE B.05
FL OUT = 1354.00 (12" W)
MODIFIED SW-402 (STA 0+89)
WATER CONTROL STRUCTURE
SEE B.01
TOP = 1365.50
FL IN = 1353.00 (12" E)
FL OUT = 1353.00 (12" SW)
STA 1+71
12" APRON, FOOTING, BAR GUARD
DAYLIGHT ELEV. 1350.50
FL IN = 1350.50 (12" NE)
GRADE COVER BERM
TO DRAIN DOWNHILL
NORMAL POOL (1360.00)
DEEP WATER AREA (<1357.00)
100-YEAR HWL (1363.49)
PROPOSED EASEMENT BOUNDARY
RIP-RAP
EXCAVATE TO 1359.00
FILL TO 1357.50
STRUCTURE SEEDING
LEGEND
0+00
1+00
2+00
3+00
4+00
BP
: 0
+0 0.
PI
: 0
+4 5.
PI
: 2
+2 5.
PI
: 3
+6 0.
EP
: 4
+0 0.
STA 2+25
34° BEND
FL IN = 1362.29 (6" NE)
FL OUT = 1362.29 (6" S)
STA 6+16
CONNECT TO 30" RCP TILE MAIN
MATCH PIPE CENTERLINES
FL IN = 1362.17 (6" N)
FL IN = 1361.14 (30" NE)
FL OUT = 1361.14 (30" SW)
30" RCP TILE MAIN
SHEET
B ol to n
M en k, In c.
5, A ll Ri gh ts
R es er ve d c h:
\I
DA
LS
\2
5x
0\
CA
D\
C3 D\
M
.d w g
6/ 1/
:1
0:
A M
DESIGNED
DRAWN
CHECKED
CLIENT PROJ. NO.
DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP
IDALS PROJ. NO. CLA953734C
BCS
NVD
JPR
25X.140338.000
1.1 FINAL DESIGN REV. 1 02-25-20261519 BALTIMORE DRIVE
AMES, IA 50010
Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR
FEETSCALE
0 25 50
HORZ.
FEETSCALE
0 5 10
VERT. M.02
PLAN & PROFILE - DRAWDOWN PIPE & NEW TILE INSTALLATION
R
NEW TILE INSTALLATIONDRAWDOWN PIPE
R
| Sheets and Views |
| A.01 TITLE SHEET |
| A.02 PLAN OVERVIEW |
| A.03 EXISTING CONDITIONS AND REMOVALS |
| B.01 WATER CONTROL STRUCTURE DETAILS |
| B.02 SHEET PILE DETAILS |
| B.03 CPDT INSTALLATION DETAILS |
| B.04 RCP INSTALLATION DETAILS |
| B.05 MISCELLANEOUS DETAILS |
| C.01 ESTIMATED QUANTITIES |
| D.01 GRADING OVERVIEW |
| D.02 PLAN & PROFILE - EMBANKMENT |
| D.03 PLAN & PROFILE - STILLING BASIN & OUTLET CHANNEL |
| D.04 PLAN & PROFILE - AUXILIARY SPILLWAY |
| D.05 PLAN & PROFILE - DIVERSION BERMS |
| K.01 SEEDING OVERVIEW |
| M.01 PLAN & PROFILE - TILE MAIN RE-LAY |
| M.02 PLAN & PROFILE - DRAWDOWN PIPE & NEW TILE INSTALLATION |
| 2026-06-10T12:30:18-0500 | |
| Brandon Short |
File details come from the government source that posted it. Updated .