This is an engineering drawing set for a residential sewer service replacement project at the Seeley Lake Ranger District facility in Montana. The project involves replacing existing 4-inch sewer service lines with new 4-inch Schedule 40 PVC pipe and upsizing one sewer service to 6-inch Schedule 40 PVC pipe. The work includes approximately 110 feet and 220 feet of sewer line replacement, connecting to existing Manhole #1, with specified minimum slopes of 3% and 1.0% respectively.
The drawings detail installation requirements including Schedule 40 PVC piping, Type 1 pipe bedding material, detectable warning tape placement, surface restoration specifications, and concrete encasement for wye sections. The project is located at the U.S. Forest Service Seeley Lake Ranger District office at 3538 MT-83, Seeley Lake, MT 59868, under the Lolo National Forest, Region One. The drawing set consists of four sheets dated March 2025, including a cover sheet with location maps, plan view, and detailed construction specifications for trenching, pipe installation, cleanout requirements, and tie-in procedures to existing infrastructure.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1240LU25Q0057 Amendment 0001.pdf | ||
| Clarifications.pdf | ||
| Section B Schedule of Items.xlsx | XLSX spreadsheet | |
| Sections D - M.pdf | ||
| Wage Determination MT20250067 06-06-2025.pdf | ||
| FSSS.docx | DOCX document | |
| 1240LU25Q0057.pdf | ||
| Section C.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FOREST LOCATION MAP
PROJECT LOCATION MAP
TRAVEL DIRECTIONS:
SHEET OF
United States Department of Agriculture Forest Service
SEELEY LAKE RANGER DISTRICT
FROM THE TOWN OF SEELEY LAKE, MT, TRAVEL NORTHWEST ON MT-83 TOWARD NORDIC WAY FOR APPROXIMATELY 3.1 MILES, TURN LEFT TO REACH SEELEY LAKE RANGER DISTRICT OFFICE AT 3538
MT-83, SEELEY LAKE, MT 59868. LAT 47.213741° LON -113.522206
RESIDENTIAL SEWER SERVICE REPLACEMENT
RECOMMENDED BY:
APPROVED:
FOREST ENGINEER
DISTRICT RANGER DATE
DATE
DIRECTOR OF ENGINEERING DATE
FOREST SUPERVISOR DATE
RO FACILITIES PROGRAM MANAGER DATE
3/2 5/2
5 1 5:
D
US
TI
NF
AR
RE
N
C:
\U
SE
RS
\D
US
TI
NF
AR
RE
N\
BO
X\
EN
GI
NE
ER
IN
G\
EN
GI
NE
ER
IN
GM
GM
T\
EN
GR
SP
AC
E\
DU
ST
IN
F
AR
RE
N
EN
GI
NE
ER
IN
G
PR
OJ
EC
TS
\S
EE
LE
Y
LA
KE
S
EW
ER
S
ER
VI
CE
R
EP
LA
CE
ME
NT
\S
EE
LE
Y
RA
NG
ER
D
IS
TR
IC
T
SE
W
ER
S
ER
VI
CE
R
EP
LA
CE
ME
NT
P
LA
NS
.D W
G;
MONTANA
SEELEY LAKE, MT
REGION ONE
LOLO NATIONAL FOREST
SEELEY LAKE RANGER DISTRICT
INDEX OF SHEETS
SHEET SHEET TITLE DATE
1 COVERSHEET 3/20/2025
2 PLAN VIEW 3/20/2025
3 DETAILS 1 3/20/2025
4 DETAILS 2 3/20/2025
SEELEY LAKE RANGER DISTRICT
3583 MT-83
SEELEY LAKE, MT 59868
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
3/2 5/2
5 1 5:
D
US
TI
NF
AR
RE
N
C:
\U
SE
RS
\D
US
TI
NF
AR
RE
N\
BO
X\
EN
GI
NE
ER
IN
G\
EN
GI
NE
ER
IN
GM
GM
T\
EN
GR
SP
AC
E\
DU
ST
IN
F
AR
RE
N
EN
GI
NE
ER
IN
G
PR
OJ
EC
TS
\S
EE
LE
Y
LA
KE
S
EW
ER
S
ER
VI
CE
R
EP
LA
CE
ME
NT
\S
EE
LE
Y
RA
NG
ER
D
IS
TR
IC
T
SE
W
ER
S
ER
VI
CE
R
EP
LA
CE
ME
NT
P
LA
NS
.D W
G;
REGION 1
SEELEY
RESIDENTIAL
SEWER SERVICE
REPLACEMENT
LOLO NATIONAL FOREST
SEELEY RANGER DISTRICT
PLAN VIEW
2024-09-09
DUSTIN FARREN
DUSTIN FARREN
NATE KEGEL
2 4
APPROX. 110 FEET
APPROX 220 FEET
REPLACE EXISTING 4" SEWER
SERVICE WITH 4" SCH. 40 PVC
UPPER I.E. = 4025.00
LOWER I.E. = 4017.50
MINIMUM 3% SLOPE
CONNECT NEW PVC
SERVICES TO EXISTING
MANHOLE #1
UPSIZE THIS SEWER SERVICE
TO 6" SCH 40 PVC
UPPER I.E. = 4015.00
LOWER I.E. = 4013.90
MINIMUM SLOPE = 1.0%
NOTES:
1. SEWER SERVICES SHALL HAVE CLEANOUTS INSTALLED
WITHIN 3 FEET OF BUILDINGS, AT ANGLES GREATER
THAN 45°, AND CONTINUOUS LENGTHS GREATER THAN
100 FEET.
2. SEWER SERVICES SHALL BE SCHEDULE 40 PVC AND
SHALL BE INSTALLED WITH CONTINUOUS MINIMUM
SLOPES SPECIFIED, WITH NO DIPS.
3. NEW SEWER SERVICES SHALL CONNECT TO BUILDINGS
AT THEIR FOUNDATIONS.
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
DustinFarren Highlight
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
3/2 5/2
5 1 5:
D
US
TI
NF
AR
RE
N
C:
\U
SE
RS
\D
US
TI
NF
AR
RE
N\
BO
X\
EN
GI
NE
ER
IN
G\
EN
GI
NE
ER
IN
GM
GM
T\
EN
GR
SP
AC
E\
DU
ST
IN
F
AR
RE
N
EN
GI
NE
ER
IN
G
PR
OJ
EC
TS
\S
EE
LE
Y
LA
KE
S
EW
ER
S
ER
VI
CE
R
EP
LA
CE
ME
NT
\S
EE
LE
Y
RA
NG
ER
D
IS
TR
IC
T
SE
W
ER
S
ER
VI
CE
R
EP
LA
CE
ME
NT
P
LA
NS
.D W
G;
REGION 1
SEELEY
RESIDENTIAL
SEWER SERVICE
REPLACEMENT
LOLO NATIONAL FOREST
SEELEY RANGER DISTRICT
DETAILS
2024-09-09
DUSTIN FARREN
DUSTIN FARREN
NATE KEGEL
3 4
VA
R
IA
BL
E
EXISTING AGGREGATE
SURFACE COURSE TO
REMAIN
1" MINUS CRUSHED AGGREGATE
SURFACE COURSE (6" MIN. DEPTH)
TYPE "B" SURFACE RESTORATION
PVC SEWER PIPE OR
HDPE PIPE AND TRACER WIRE
SUITABLE NATIVE BACKFILL
12" MINIMUM TO
UNDISTURBED AGGREGATE
SURFACE COURSE
TYPE 1 PIPE BEDDING MATERIAL
DETECTABLE BURIED
WARNING TAPE
(MAXIMUM OF 18" BELOW
FINISH GRADE)
TYPICAL UTILITY TRENCH WITH
8'
VA
R
IA
BL
E
SEED DISTURBED AREAS BEYOND
PAY LIMIT AS REQUIRED
RESEED
6" TOPSOIL MIN.
PVC SEWER PIPE OR HDPE
PIPE AND TRACER WIRE
TYPE "C" SURFACE RESTORATION
PAY LIMIT
TYPE 1 PIPE BEDDING MATERIAL
SUITABLE NATIVE BACKFILL
DETECTABLE BURIED
WARNING TAPE
(MAXIMUM OF 18" BELOW
FINISH GRADE)
TYPICAL UTILITY TRENCH WITH
EXISTING MANHOLE TIE-IN
UPSIZE THIS SEWER SERVICE
TO 6" SCH 40 PVC
UPPER I.E. = 4015.00
LOWER I.E. = 4013.90
MINIMUM SLOPE = 1.0%
REPLACE EXISTING 4" SEWER
SERVICE WITH 4" SCH. 40 PVC
UPPER I.E. = 4025.00
LOWER I.E. = 4017.50
MINIMUM 3% SLOPE
8'
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VARIABLE
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VARIABLE
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
DustinFarren Highlight
DustinFarren Highlight
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
3/2 5/2
5 1 5:
D
US
TI
NF
AR
RE
N
C:
\U
SE
RS
\D
US
TI
NF
AR
RE
N\
BO
X\
EN
GI
NE
ER
IN
G\
EN
GI
NE
ER
IN
GM
GM
T\
EN
GR
SP
AC
E\
DU
ST
IN
F
AR
RE
N
EN
GI
NE
ER
IN
G
PR
OJ
EC
TS
\S
EE
LE
Y
LA
KE
S
EW
ER
S
ER
VI
CE
R
EP
LA
CE
ME
NT
\S
EE
LE
Y
RA
NG
ER
D
IS
TR
IC
T
SE
W
ER
S
ER
VI
CE
R
EP
LA
CE
ME
NT
P
LA
NS
.D W
G;
REGION 1
SEELEY
RESIDENTIAL
SEWER SERVICE
REPLACEMENT
LOLO NATIONAL FOREST
SEELEY RANGER DISTRICT
DETAILS
2024-10-09
DUSTIN FARREN
DUSTIN FARREN
NATE KEGEL
4 4
GENERAL NOTES:
1. ENTIRE WYE SECTION TO BE ENCASED IN CONCRETE.
STANDARD CLEANOUT
A A
SECTION A-A
CONCRETE COLLAR TO BE USED
(EXCEPT IN PAVED AREAS)
CLEAN-OUT SHALL BE AN
IRON BODY FERRULE WITH
BRASS SCREW PLUG
CONCRETE COLLAR
CONCRETE
ENCASEMENT
PIPE BEDDING
SERVICE
LINE
CONCRETE
ENCASEMENT
TRENCH WIDTH
#4 BAR
EACH WAY
6" (TYP.)
O .D
2"
O.D. + 12"
6" 6"
4" MIN.
4"
TRENCH WIDTH OR 12" MIN.
S
ASSISTANT'S RESIDENCE PROFILE
RANGER'S RESIDENCE PROFILE
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets and Views |
| Seeley Ranger District Sewer Service Replacement Plans-COVERSHEET |
| OLE1 |
| Seeley Ranger District Sewer Service Replacement Plans-PLAN VIEW |
| OLE1 |
| Seeley Ranger District Sewer Service Replacement Plans-DETAILS 1 |
| OLE1 |
| Seeley Ranger District Sewer Service Replacement Plans-DETAILS 2 |
| OLE1 |
| 2025-04-21T07:19:25-0600 | |
| NATHAN KEGEL |
| 2025-04-23T16:45:16-0600 | |
| CHARLES CARVER |
| 2025-04-30T08:51:19-0600 | |
| JEREMY CASTERSON |
| 2025-04-18T13:43:28-0600 | |
| ANDREW MCPHERSON |
| 2025-05-05T13:43:33-0600 | |
| CORRINE KEGEL |
File details come from the government source that posted it. Updated .