This document contains exhibits and specifications for the replacement of HVAC equipment at the Pleasant Hill High School Music Complex and Multi-Purpose buildings. The project involves the replacement of 20 rooftop HVAC units across 29 tagged locations on the campus, with capacities ranging from 3 to 20 tons. The units feature various cooling and heating configurations, including single-stage and two-stage cooling, and single-stage gas heat. The equipment will be provided by the Fraser-Johnston brand and specified to meet energy efficiency and regulatory requirements. The procurement and installation of the HVAC units are part of a state and local contract opportunity issued by the Pleasant Hill School District in Lane County, Oregon.
The document provides detailed technical specifications and performance data for each unit model, as well as drawings showing the component locations and control diagrams. It also includes information on factory-installed options, field-installed accessories, and warranty coverage. The project timeline, bid requirements, and other relevant details are outlined in the separate state and local contract opportunity document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EX. 1 - RTU 26 Multi-Purpose Room EX. 2 - RTU 27 Music Complex (North Music Room)
EX. 3 - RTU 28 Music Complex (Choir Room) EX. 4 - RTU 29 Music Complex (Band Room)
Date 02/10/2022 Project Name Pleasant Hill Phase 2 Project Number Client / Purchaser
Submittal Summary Page
Qty Tag # Model # / Material # Description 1 RTU-26 ZS-20S30U4B1ACA2A1 20 Ton, Single Packaged R-410A Air Conditioner, Two Stage
Cooling, 9.8 EER, 300 MBH Input Stainless Steel, Two Stage Gas Heat, 460-3-60, Single Wall Construction
• VFD with Bypass and Intellispeed
• Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom Return Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 7.5 HP High Static Belt Drive Blower
• 2" Pleated Filters (MERV 8)
• Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 Communication Card.
• Standard Condenser Coil
• Standard Evaporator Coil
• Standard Access Doors
• Galvanized Steel Drain Pan
1 RTU-26 ZW-20S30U4B1ACA2A1 20 Ton, Single Packaged R-410A Air Conditioner, Four Stage Cooling, 11.0 EER, 300 MBH Input Stainless Steel, Two Stage Gas Heat, 460-3-60, Single Wall Construction
• VFD with Bypass and Intellispeed
• Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom Return Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 7.5 HP High Static Belt Drive Blower
• 2" Pleated Filters (MERV 8)
• Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 Communication Card.
• Standard Condenser Coil
• Standard Evaporator Coil
• Standard Access Doors
• Galvanized Steel Drain Pan
Equipment start-up and commissioning by a factory trained technician is recommended.
Contact your supplying distributor or sales representative for additional information & guidance.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Information is subject to change without notice. Check local codes.
EX. 5 - Replacement Unit Specifications hrobinet Highlight
Cooling Performance Total gross capacity 260.4 MBH Sensible gross capacity 189.3 MBH Total net capacity 240.9 MBH Sensible net capacity 169.8 MBH Efficiency (at ARI) 9.80 EER Integrated eff. (at ARI) 12.30 IEER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 58.1 °F Leaving WB temp. 56.7 °F Leaving air temp dew point 55.80 °F Power input (w/o blower) 22.57 kW Sound power 92 dB(A)
Refrigerant Refrigerant type R-410A Sys1 22 lbs Sys2 23 lbs 8 oz
Gas Heating Performance Entering DB temp. 65 °F Heating output capacity (Max) 240 MBH Supply air 8000 CFM Heating input capacity (Max) 300 MBH Leaving DB temp. 92.8 °F Air temp. rise 27.8 °F
SSE 80.0 %
Stages 2
Supply Air Blower Performance Supply air 8000 CFM Ext. static pressure 1.0 IWG Addl. Unit Losses (Options/Accessories) 0.15 IWG Blower speed 1023 RPM Max BHP of Motor (including service factor) 8.63 HP Duct location Bottom Motor rating 7.50 HP Actual required BHP 6.83 HP Power input 5.72 kW Elevation 0 ft.
Drive type BELT
Electrical Data Power supply 460-3-60 Unit min circuit ampacity 54.3 Amps Unit max over-current protection 70 Amps
Dimensions & Weight Hgt 53 in. Len 137 in. Wth 92 in.
Weight with factory installed options 2933 lbs.
Clearances Right 36 in. Front 36 in. Rear 49 in.
Top 72 in. Bottom 0 in. Left 24 in.
Note: Please refer to the tech guide for listed maximum static pressures
20 Ton
• Fraser-Johnston Units are Manufactured at an ISO 9001 Registered Facility and each Rooftop is Completely Computer-Run Tested Prior to Shipment.
Unit Features
• Two Stage Cooling
• 300 MBH Input Stainless Steel, Two Stage Gas Heat
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 750 Hours Salt Spray Test (ASTM B-117 Standards).
• Either Supply and/or Return can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels
• Full Perimeter Base Rails with Built in Rigging Capabilities
• Dual Refrigerant Circuits for Efficient Part Load Operation with Scroll Compressors
• Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom Return Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 7.5 HP High Static Belt Drive Blower
• 2" Pleated Filters (MERV 8)
• Solid Core Liquid Line Filter Driers
• Replacement Filters: For 2" filters 12 - (12" x 24" x 2") OR For 4" filters 2 - (20" X 24" x 4") AND 4 - (24" X 24" x 4")
• Short Circuit Current: 5kA RMS Symmetrical
• Single Point Power Connection
• Through-the-Curb and Through-The-Base Utility Connections
• Standard Condenser Coil
• Standard Evaporator Coil
• Crane Required to Unload Unit
• Galvanized Steel Drain Pan
• Standard Access Doors BAS Controller
• VFD with Bypass and Intellispeed
• Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 communication card.
Standard Unit Controller: Smart Equipment Control Board
• An Integrated Low-Ambient Control, Anti-Short Cycle Protection, Lead-Lag, Fan On and Fan off Delays, Low Voltage Protection, On-Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention.
• Safety Monitoring - Monitors the High and Low-Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips.
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• Fifteen (15) Year Warranty - Stainless Steel Tubular Heat Exchangers
Information is subject to change without notice. Check local codes.
ReliaPlus™ 100 15-25 Ton Package
Fraser-Johnston Single Package R-410A Air Conditioner
Project Name: Pleasant Hill Phase 2 Unit Model #: ZS-20S30U4B1ACA2A1 Quantity: 1 Tag #: RTU-26 System: ZS-20S30U4B1ACA2A1
Additional Electrical Data Power supply 460-3-60 Unit min circuit ampacity 54.3 Amps Unit max over-current protection 70 Amps Min Voltage 432 V Max Voltage 504 V Comp #1 RLA 17.9 Comp #1 LRA 125 Comp #2 RLA 17.9 Comp #2 LRA 125 Indoor Mtr Voltage 460-3-60 Indoor Mtr FLA 9.7 Outdoor Mtr Qty 2 Outdoor Fan Voltage 460-3-60 OD Fan Mtr FLA (ea.) 2.2 Power Ex Mtr Qty 1 Powered Ex Voltage 460-1-60 Power Ex Mtr FLA (ea) 2.2 Combustion Mtr Qty 1 Combustion Motor Voltage 460-1-60 Combustion Mtr FLA (ea) 0.3
ReliaPlus™ 100 15-25 Ton Package
Fraser-Johnston Single Package R-410A Air Conditioner
Project Name: Pleasant Hill Phase 2 Unit Model #: ZS-20S30U4B1ACA2A1 Quantity: 1 Tag #: RTU-26 System: ZS-20S30U4B1ACA2A1
Consolidated Drawing
Information is subject to change without notice. Check local codes.
ReliaPlus™ 100 15-25 Ton Package Fraser-Johnston Single Package R-410A Air Conditioner
Project Name: Pleasant Hill Phase 2 Unit Model #: ZS-20S30U4B1ACA2A1 Quantity: 1 Tag #: RTU-26
Component Locations
ReliaPlus™ 100 15-25 Ton Package
Fraser-Johnston Single Package R-410A Air Conditioner
Project Name: Pleasant Hill Phase 2 Unit Model #: ZS-20S30U4B1ACA2A1 Quantity: 1 Tag #: RTU-26
Typical Control Diagram
ReliaPlus™ 100 15-25 Ton Package
Fraser-Johnston Single Package R-410A Air Conditioner
Project Name: Pleasant Hill Phase 2 Unit Model #: ZS-20S30U4B1ACA2A1 Quantity: 1 Tag #: RTU-26
Project Name Pleasant Hill Phase 2 Project Number Client / Purchaser
Submittal Summary Page
Qty Tag # Model # / Material # Description
11 RTU-
1,2,3,4,5,6,1 1,12,13,17,2
ZE036J05B4C1ACA2B2 3 Ton, Single Packaged R-410A Air Conditioner, Single Stage Cooling, 12.0 EER / 14.0 SEER, Single Stage Gas Stainless Steel, 50 MBH Input, 460-3-60
• Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 1.5 HP Standard Static Belt Drive Blower
• 2" Pleated Filters (MERV 8)
• Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 Communication Card.
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil
• Galvanized Steel Drain Pan
• Hinged & Tool Free Filter, Motor, and Electrical Access Panels
11 RTU-
1,2,3,4,5,6,1 1,12,13,17,2
1RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted)
1 RTU-7 ZE072J10D4C1ACA2B1 6 Ton, Single Packaged R-410A Air Conditioner, Two Stage Cooling / Intellispeed w/VFD Standard, 11.00 EER, Single Stage Gas Stainless Steel, 100 MBH Input, 460-3-60
• Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 3 HP High Static Belt Drive Blower
• 2" Pleated Filters (MERV 8)
• Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 Communication Card.
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil
• Galvanized Steel Drain Pan
• Hinged & Tool Free Filter, Motor, and Electrical Access Panels
1 RTU-7 1RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted)
10 RTU-
8,9,10,15,18, 21,22,23,27, ZE048J07B4C1ACA2B2 4 Ton, Single Packaged R-410A Air Conditioner, Single Stage Cooling, 12.0 EER / 14.0 SEER, Single Stage Gas Stainless Steel, 75 MBH Input, 460-3-60
• Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE
Information is subject to change without notice. Check local codes. Page 27 of 39 hrobinet Highlight hrobinet Highlight
Qty Tag # Model # / Material # Description 90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 1.5 HP Standard Static Belt Drive Blower
• 2" Pleated Filters (MERV 8)
• Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 Communication Card.
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil
• Galvanized Steel Drain Pan
• Hinged & Tool Free Filter, Motor, and Electrical Access Panels
10 RTU-
8,9,10,15,18, 21,22,23,27, 1RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted)
5 RTU-
14,16,24,25, ZE060J10B4C1ACA2B2 5 Ton, Single Packaged R-410A Air Conditioner, Single Stage Cooling, 11.8 EER / 14.0 SEER, Single Stage Gas Stainless Steel, 100 MBH Input, 460-3-60
• Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 1.5 HP Standard Static Belt Drive Blower
• 2" Pleated Filters (MERV 8)
• Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 Communication Card.
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil
• Galvanized Steel Drain Pan
• Hinged & Tool Free Filter, Motor, and Electrical Access Panels
5 RTU-14,16, 1RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted)
Equipment start-up and commissioning by a factory trained technician is recommended.
Contact your supplying distributor or sales representative for additional information & guidance.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Information is subject to change without notice. Check local codes. Page 28 of 39 hrobinet Highlight hrobinet Highlight hrobinet Highlight hrobinet Highlight
Total gross capacity 50.8 MBH Sensible gross capacity 36.7 MBH Total net capacity 48.1 MBH Sensible net capacity 34.0 MBH Seasonal Efficiency (at ARI) 14.00 SEER Efficiency (at ARI) 12.00 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 58.8 °F Leaving WB temp. 56.9 °F Leaving air temp dew point 55.70 °F Power input (w/o blower) 3.49 kW Sound power 80 dB(A)
Refrigerant Refrigerant type R-410A Sys1 5 lbs 6 oz
Gas Heating Performance Entering DB temp. 65 °F Heating output capacity (Max) 59 MBH Supply air 1600 CFM Heating input capacity (Max) 75 MBH Leaving DB temp. 99.1 °F Air temp. rise 34.1 °F
SSE 80.0 %
Stages 1
Supply Air Blower Performance Supply air 1600 CFM Ext. static pressure 0.75 IWG Addl. Unit Losses (Options/Accessories) 0.11 IWG Blower speed 1092 RPM Max BHP of Motor (including service factor) 1.73 HP Duct location Bottom Motor rating 1.50 HP Actual required BHP .87 HP Power input 0.81 kW Elevation 0 ft.
Drive type BELT
Electrical Data Power supply 460-3-60 Unit min circuit ampacity 11 Amps Unit max over-current protection 15 Amps
Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in.
Weight with factory installed options 708 lbs.
Clearances Right 24 in. Front 32 in. Rear 12 in.
Top 72 in. Bottom 0 in. Left 24 in.
Note: Please refer to the tech guide for listed maximum static pressures
4 Ton
• Fraser-Johnston Units are Manufactured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer-Run Tested Prior to Shipment.
Unit Features
• Single Stage Cooling
• Single Stage Gas Stainless Steel
• 75 MBH Input
• Either Supply and/or Return can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels.
• Full Perimeter Base Rails with Built in Rigging Capabilities
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 750 Hours Salt Spray Test (ASTM B-117 Standards)
• Scroll Compressor
• Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 1.5 HP Standard Static Belt Drive Blower
• Solid Core Liquid Line Filter Driers
• 2" Pleated Filters (MERV 8)
• Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2").
Unit accepts 1" or 2" wide filters.
• Short Circuit Current: 5kA RMS Symmetrical
• Through-the-Curb and Through-The-Base Utility Connections
• Single Point Power Connection
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil
• Galvanized Steel Drain Pan
• Hinged & Tool Free Filter, Motor, and Electrical Access Panels Standard Unit Controller: Smart Equipment Control Board
• Safety Monitoring - Monitors the High and Low-Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips.
• An Integrated Low-Ambient Control, Anti-Short Cycle Protection, Lead-Lag, Fan On and Fan off Delays, Low Voltage Protection, On-Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention.
BAS Controller
• Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 communication card.
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• Fifteen (15) Year Warranty - Stainless Steel Heat Exchanger
Information is subject to change without notice. Check local codes.
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE048J07B4C1ACA2B2 Quantity: 10 Tag #: RTU- 8,9,10,15,18,21,22,23,27,28
System: ZE048J07B4C1ACA2B2 hrobinet Highlight
Unit min circuit ampacity 11 Amps Unit max over-current protection 15 Amps Min Voltage 432 V Max Voltage 504 V Comp #1 RLA 6.2 Comp #1 LRA 41.0 Indoor Mtr Voltage 460-3-60 Indoor Mtr FLA 2.1 Outdoor Mtr Qty 1 Outdoor Fan Voltage 460-1-60 OD Fan Mtr FLA (ea.) 1.1
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE048J07B4C1ACA2B2 Quantity: 10 Tag #: RTU- 8,9,10,15,18,21,22,23,27,28
System: ZE048J07B4C1ACA2B2 hrobinet Highlight
Factory Installed Options
ZE048J07B4C1ACA2B2
Equipment Options Option(s) Selected
Product Category: ZE Single Packaged R-410A Air Conditioner
12.0 EER / 14.0 SEER
Nominal Cooling Capacity: 048 4 Ton Single Stage Cooling
Heat Type and Nominal Heat Capacity: J07 Single Stage Gas Stainless Steel 75 MBH Input
Blower Option: B 1.5 HP Standard Static Belt Drive Blower
Voltage: 4 460-3-60
Outside Air Option: C Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title
24, AMCA 511)
Service Options: 1 Sensor Options: A
Controls: C Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors.
BACNet MS/TP, Modbus and N2 Communication Card.
Refrigeration: A Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil
Additional Options: 2 2" Pleated Filters (MERV 8)
Cabinet Options: B Galvanized Steel Drain Pan Hinged & Tool Free Filter, Motor, and Electrical Access Panels
Field Installed Accessories 1BD0401 - Burglar Bars (25.0 lbs) 1CG0401 - Coil Guard (11.0 lbs) 1CV0402 - Concentric Diffuser,Flush Mount,18RD
1CV0411 - Concentric Diffuser,Side Discharge,18RD (55.0 lbs)
1CV0419 - Concentric Diffuser,Specialty,18X18
1FE0405 - Flue Extension Kit (25.0 lbs)
1GP0401 - Gas Piping Kit for Bottom Gas Supply Connection with External Shut-Off (includes:
Internal gas pipe, fittings, gas cock & panel gaskets) (5.0 lbs)
1HG0401 - Hail Guard Kit (51.0 lbs)
1LN0406 - Low NOx Kit - Required to reduce the emission of nitrogen oxides below 40 nanograms per joule.
1NP0440 - Natural Gas to Propane Conversion Kit (1-Stage) (1.0 lbs)
1RC0434 - Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (86.0 lbs)
1RC0442 - Roof Curb - 12" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (78.0 lbs)
1RC0465 - Roof Curb - 8" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (67.0 lbs)
1RD0410 - Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mo unted) (6.0 lbs)
Information is subject to change without notice. Check local codes.
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE048J07B4C1ACA2B2 Quantity: 10 Tag #: RTU- 8,9,10,15,18,21,22,23,27,28
System: ZE048J07B4C1ACA2B2 hrobinet Highlight
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE048J07B4C1ACA2B2 Quantity: 10 Tag #: RTU-8,9,10,15,18,21,22,23,27,28 hrobinet Highlight
Component Location
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE048J07B4C1ACA2B2 Quantity: 10 Tag #: RTU- 8,9,10,15,18,21,22,23,27,28 hrobinet Highlight
Total gross capacity 61.1 MBH Sensible gross capacity 45.4 MBH Total net capacity 57.1 MBH Sensible net capacity 41.4 MBH Seasonal Efficiency (at ARI) 14.00 SEER Efficiency (at ARI) 11.80 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 59.0 °F Leaving WB temp. 57.3 °F Leaving air temp dew point 56.20 °F Power input (w/o blower) 4.28 kW Sound power 82 dB(A)
Refrigerant Refrigerant type R-410A Sys1 6 lbs 4 oz
Gas Heating Performance Entering DB temp. 65 °F Heating output capacity (Max) 80 MBH Supply air 2000 CFM Heating input capacity (Max) 100 MBH Leaving DB temp. 102.0 °F Air temp. rise 37.0 °F
SSE 80.0 %
Stages 1
Supply Air Blower Performance Supply air 2000 CFM Ext. static pressure 0.75 IWG Addl. Unit Losses (Options/Accessories) 0.15 IWG Blower speed 1212 RPM Max BHP of Motor (including service factor) 1.73 HP Duct location Bottom Motor rating 1.50 HP Actual required BHP 1.26 HP Power input 1.17 kW Elevation 0 ft.
Drive type BELT
Electrical Data Power supply 460-3-60 Unit min circuit ampacity 14.1 Amps Unit max over-current protection 20 Amps
Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in.
Weight with factory installed options 752 lbs.
Clearances Right 24 in. Front 32 in. Rear 12 in.
Top 72 in. Bottom 0 in. Left 24 in.
Note: Please refer to the tech guide for listed maximum static pressures
5 Ton
• Fraser-Johnston Units are Manufactured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer-Run Tested Prior to Shipment.
Unit Features
• Single Stage Cooling
• Single Stage Gas Stainless Steel
• 100 MBH Input
• Either Supply and/or Return can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels.
• Full Perimeter Base Rails with Built in Rigging Capabilities
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 750 Hours Salt Spray Test (ASTM B-117 Standards)
• Scroll Compressor
• Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511)
• 1.5 HP Standard Static Belt Drive Blower
• Solid Core Liquid Line Filter Driers
• 2" Pleated Filters (MERV 8)
• Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2").
Unit accepts 1" or 2" wide filters.
• Short Circuit Current: 5kA RMS Symmetrical
• Through-the-Curb and Through-The-Base Utility Connections
• Single Point Power Connection
• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil
• Galvanized Steel Drain Pan
• Hinged & Tool Free Filter, Motor, and Electrical Access Panels Standard Unit Controller: Smart Equipment Control Board
• Safety Monitoring - Monitors the High and Low-Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips.
• An Integrated Low-Ambient Control, Anti-Short Cycle Protection, Lead-Lag, Fan On and Fan off Delays, Low Voltage Protection, On-Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention.
BAS Controller
• Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors. BACNet MS/TP, Modbus and N2 communication card.
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• Fifteen (15) Year Warranty - Stainless Steel Heat Exchanger
Information is subject to change without notice. Check local codes.
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE060J10B4C1ACA2B2 Quantity: 5 Tag #: RTU-14,16,24,25,29 System: ZE060J10B4C1ACA2B2 hrobinet Highlight
Unit min circuit ampacity 14.1 Amps Unit max over-current protection 20 Amps Min Voltage 432 V Max Voltage 504 V Comp #1 RLA 7.8 Comp #1 LRA 52 Indoor Mtr Voltage 460-3-60 Indoor Mtr FLA 2.1 Outdoor Mtr Qty 1 OD Fan Mtr FLA (ea.) 4.4 Combustion Mtr Qty 1 Combustion Motor Voltage 208/230-1-60 Combustion Mtr FLA (ea) 0.8
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE060J10B4C1ACA2B2 Quantity: 5 Tag #: RTU-14,16,24,25,29 System: ZE060J10B4C1ACA2B2 hrobinet Highlight
Factory Installed Options
ZE060J10B4C1ACA2B2
Equipment Options Option(s) Selected
Product Category: ZE Single Packaged R-410A Air Conditioner
11.8 EER / 14.0 SEER
Nominal Cooling Capacity: 060 5 Ton Single Stage Cooling
Heat Type and Nominal Heat Capacity: J10 Single Stage Gas Stainless Steel 100 MBH Input
Blower Option: B 1.5 HP Standard Static Belt Drive Blower
Voltage: 4 460-3-60
Outside Air Option: C Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title
24, AMCA 511)
Service Options: 1 Sensor Options: A
Controls: C Smart Equipment Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors.
BACNet MS/TP, Modbus and N2 Communication Card.
Refrigeration: A Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil
Additional Options: 2 2" Pleated Filters (MERV 8)
Cabinet Options: B Galvanized Steel Drain Pan Hinged & Tool Free Filter, Motor, and Electrical Access Panels
Field Installed Accessories 1BD0401 - Burglar Bars (25.0 lbs) 1CG0401 - Coil Guard (11.0 lbs) 1CV0402 - Concentric Diffuser,Flush Mount,18RD
1CV0411 - Concentric Diffuser,Side Discharge,18RD (55.0 lbs)
1CV0419 - Concentric Diffuser,Specialty,18X18
1FE0405 - Flue Extension Kit (25.0 lbs)
1GP0401 - Gas Piping Kit for Bottom Gas Supply Connection with External Shut-Off (includes:
Internal gas pipe, fittings, gas cock & panel gaskets) (5.0 lbs)
1HG0413 - Hail Guard Kit (51.0 lbs)
1LN0406 - Low NOx Kit - Required to reduce the emission of nitrogen oxides below 40 nanograms per joule.
1NP0440 - Natural Gas to Propane Conversion Kit (1-Stage) (1.0 lbs)
1RC0434 - Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (86.0 lbs)
1RC0442 - Roof Curb - 12" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (78.0 lbs)
1RC0465 - Roof Curb - 8" High, Flat, Uninsulated, Full Perimeter (Shipped Knocked Down) (67.0 lbs)
1RD0410 - Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted 6.0 lbs)
Information is subject to change without notice. Check local codes.
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE060J10B4C1ACA2B2 Quantity: 5 Tag #: RTU-14,16,24,25,29 System: ZE060J10B4C1ACA2B2 hrobinet Highlight
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE060J10B4C1ACA2B2 Quantity: 5 Tag #: RTU-14,16,24,25,29 hrobinet Highlight
Component Location
3-6 Ton ReliaCore™ 100
Project Name: Pleasant Hill Phase 2 Unit Model #: ZE060J10B4C1ACA2B2 Quantity: 5 Tag #: RTU-14,16,24,25,29 hrobinet Highlight
Project Name Pleasant Hill Phase 2 Project Number Client / Purchaser
Guide Specification Summary Page
Product Series Models and Unit Tags 3-6 Ton ReliaCore™ 100 ZE036J05B4C1ACA2B2 RTU-1,2,3,4,5,6,11,12,13,17,20
ZE072J10D4C1ACA2B1 RTU-7
ZE048J07B4C1ACA2B2 RTU-8,9,10,15,18,21,22,23,27,28
ZE060J10B4C1ACA2B2 RTU-14,16,24,25,29
Information is subject to change without notice. Check local codes. Page 39 of 39 hrobinet Highlight hrobinet Highlight hrobinet Highlight
| PHHS HVAC - Music & Multi Purpose Exhibits 2.4.22 |
| PHHS HVAC - Music & Multi Purpose Exhibits |
| Blank Page |
| Blank Page |
| RTU 26 Replacement Spec Sheets |
| PHHS HVAC - Music & Multi Purpose Exhibits 2.4.22 |
File details come from the government source that posted it. Updated .