PGC 00312 02768 00036 TECH DATA rev.pdf

PDF 84 KB Posted

Attached to
Undershirt, White, Crew Neck Federal contract opportunity
Solicitation number
SPE1C1-21-R-0088
Issued by
Defense Logistics Agency Troop Support Clothing and Textiles

View the file

Other files for this federal contract opportunity

Other files attached to Undershirt, White, Crew Neck, newest first.
File Type Posted
SF1449_SPE1C121R0088.pdf PDF
A-A-50013G.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECH DATA PGC00312 EACH 8/16/2021

NSN 8420005436643

TECH DATA PGC 02768 3 PACK

NSN 8420014951959

TECH DATA PGC 00036, 2 PACK

NSN 8420016690442

UNDERSHIRT, MAN'S, QUARTER SLEEVE, CREW NECK

TYPE I, WHITE

RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT

RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL

AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:

http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx

FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE

MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT

INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.

RQ009: INSPECTION AND ACCEPTANCE AT ORIGIN.

ADDITIONAL INFORMATION FOR A-A-50013:

THE UNDERSHIRT SHALL BE IN ACCORDANCE WITH

A-A-50013G, DATED SEPTEMBER 15, 2009

TYPE I, CLASS 1, WHITE CREW NECK

INTERIM CHANGES TO A-A-50013G:

PAGE I, PARA. 2.2 CLASSES. ADD THE FOLLOWING NEW CLASS

UNDER CLASS 8: "CLASS 9 - TAN 499".

PAGE 2, PARA 3.1 DESCRIPTION. LINE 2, AFTER COLLARETTE, ADD "SEAMLESS SIDES,".

PAGE 2, TABLE I. MATERIAL REQUIREMENTS.

FABRIC WEIGHT LINE, UNDER "REQUIREMENT"

DELETE "4.5 (+/- 0.2)" AND SUBSTITE "4.0 (+/- 0.2)".

PARA. 3.2.1.2 LABILE SULFUR. DELETE "3.2.1.2 LABILE SULFUR"

AND SUBSTITUTE "3.2.2.2 LABILE SULFUR".

AQL'S FOR COMMERCIAL ITEM DESCRIPTIONS (CID'S)

END ITEM DIMENSIONAL 4.0

VISUAL 2.5

ACCEPTABILITY OF LOTS WILL BE DETERMINED BY THE

USE OF "SAMPLING PROCEDURES AND TABLES FOR

INSPECTION BY ATTRIBUTES", ANSI/ASQC Z1.4

GENERAL INSPECTION LEVEL 2.

ADDITIONAL INFORMATION FOR PPP-B-636:

FEDERAL SPECIFICATION PPP-B-636 DATED JULY 12, 1981, INCLUDING INTERIM FEDERAL

SPECIFICATION PPP-B-636L DATED JANUARY 1, 1991, IS HEREBY CANCELLED, AND REPLACED WITH ASTM-D-5118, STANDARD PRACTICE FOR FABRICATION OF FIBERBOARD SHIPPING BOXES, AND ASTM- D-1974, STANDARD PRACTICE FOR METHOD OF CLOSING, SEALING AND REINFORCING FIBERBOARD

SHIPPING CONTAINERS.

ADDITIONAL INFORMATION FOR FED-STD-191:

FED-STD-191A NOTICE 7, DATED AUGUST 9, 2000 IS HEREBY INACTIVE FOR NEW DESIGN. WHEN NOT USING FED-STD-191, SEE INTERIM CHANGES TO END ITEM SPECIFICATION FOR REPLACEMENT

ASTM.

INTERIM CHANGES TO FED-STD-191A:

TEST METHOD 5202, PARA. 5.3, DELETE FIRST SENTENCE AND SUBSTITUTE: "THE SPECIMEN

SHALL BE CLAMPED FIRMLY, WITH ONE END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT ONE INCH OF SPECIMEN LIES WITHIN THE CLAMP AND ONE INCH OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION (FACE OF THE VISE), AND WITH THE LONG EDGE PARALLEL TO THE FACE

OF THE DIAL PLATE".

TEST METHOD 5309.1 ABRASION RESISTANT OF TEXTILE WEBBING. PAGE 1, PARA 4.1.2,LINE 4:

DELETE "B-97" AND SUBSTITUTE "B-91".

THE FOLLOWING METHODS ARE IDENTIFIED AS SPECIFYING OZONE DEPLETING SUBSTANCES: 1100, 1200, 1240, 1400, 1410, 1500, 1510,1520,1530, 1540, AND 1550. PARA 5.1 OF THESE TEST

METHODS REQUIRE THE USE OF 1,1,1- TRICHLOROETHANE, ALCOHOL OR ETHER. 1,1,1-

TRICHLORETHANE IS AN OZONE DEPLETING SUBSTANCE (METHYL CHLOROFORM) AND IS THEREFORE PROHIBITED. THE USE OF EITHER ALCOHOL OR ETHER IS REQUIRED WHEN THESE METHODS ARE IN

BASIC OR ANY REFERENCED DOCUMENT.

METHOD 5202, STIFFNESS OF CLOTH, DIRECTIONAL; CANTILEVER BENDING METHOD. PAGE 2,

PARA. 5.3 DELETE FIRST SENTENCE AND SUBSTITUTE WITH THE FOLLOWING: "THE SPECIMEN SHALL BE CLAMPED FIRMLY, WITH 1 END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT 1" OF THE SPECIMEN LIES WITHIN THE CLAMP AND 1" OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION (INNER FACE OF THE VISE) AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE

DIAL PLATE."

METHOD 5556.1, MOBILE LAUNDRY EVALUATION FOR TEXTILE MATERIALS, PAGE 5, PARA. 5.2.2, LINE 8: DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND BALLAST" IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE SEPARATED, OPENED TO FULL WIDTH AND PLACED IN A PRE-HEATED DRYER HAVING A STACK TEMPERATURE OF 140-180 DEG. F. THIS TEMPERATURE RANGE CORRESPONDS TO A SETTING OF "HIGH" ON THE TEMPERATURE INDICATOR ON THE DRYER. DRYING SHALL CONTINUE FOR 45-60 MINUTES OR UNTILSAMPLES ARE

DRY IN A ROTATING TUMBLE DRYER."

PAGE 5, PARA. 5.2.3, LINE 8: DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND

BALLAST" IN ITS ENTIRETY AND SUBSTITUTE WITH THEFOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE SEPARATED, OPENED TO FULL WIDTH AND PLACED IN A PRE-HEATED DRYER HAVING A STACKTEMPERATURE OF 140-180 DEG. F. THIS TEMPERATURE RANGE CORRESPONDS TO A SETTING OF "HIGH" ON THE TEMPERATURE INDICATOR ON THE DRYER. DRYING SHALL CONTINUE FOR 35-40

MINUTES OR UNTIL SAMPLES ARE DRY."

METHOD 5931, ELECTROSTATIC DECAY OF FABRICS; DETERMINATION OF PAGE 1, PARA. 3: AFTER NUMBER OF DETERMINATIONS ADD "PER SAMPLE UNIT". PAGE 1, PARA. 4: DELETE "APPARTUS"

AND SUBSTITUTE "APPARATUS". PAGE 1, PARA. 5.1, LINE 3: AFTER "AT"

DELETE"APPROXIMATELY".

PAGE 2, PARA. 5.2, LINES 2, AND 5: AFTER "OF" ADD "+-". LINE 6: AFTER "TO" ADD "+-".

PAGE 2, PARA. 5.3: DELETE IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING:"5.3 MOUNT A SPECIMEN TIGHTLY ACROSS THE ELECTRODES, CENTERING IT OVER THE SENSOR OPENING. THE SURFACE OF THE TEST SPECIMEN (BACK OR FRONT) SHALL FACE THE SENSOR. RECORD (OPTIONAL) THE RESIDUAL CHARGE LEVEL ON THE SAMPLE AS SEEN BY THE SENSOR, INCLUDING POLARITY.

NOTE THAT TEST SAMPLES WITH THE RESIDUAL CHARGE LEVELS OF LESS +500 VOLTS YIELD THE BEST RESULTS. APPLY +5000 VOLTS TO THEELECTRODES FOR A PERIOD OF 20 SECS. AT THE END OF THE 20 SECOND PERIOD, THE HIGH VOLTAGE (5000 VOLTS) SHALL BE TURNED OFF ANDTHE SPECIMENS IMMEDIATELY GROUNDED. THE VOLTAGE BEHAVIOR OF THE SPECIMEN WITH RESPECT TO TIME SHALL BE PLOTTED ON THE RECORDER. NOTE: IN SOME CASES, THE TEST EQUIPMENT WILL DISPLAY VOLTAGE AND DECAY TIME INFORMATION AND A CHART RECORDER IS NOT NECESSARY."

PAGE 2, PARA. 5.4, LINE 3: DELETE SENTENCE BEGINNING WITH "IF THE SPECIMEN DID" IN ITS

ENTIRETY.

PAGE 2, PARA. 5.5: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING:

"RECORD THE MAXIMUM VOLTAGE LEVEL(INCLUDING POLARITY) AND DECAY TIME TO 10% OF THE

MAXIMUM VOLTAGE LEVEL ACHIEVED."

PAGE 2, PARA. 5.6, LINE 1: ADD THE FOLLOWING PRIOR TO 1ST SENTENCE: "REVERSE VOLTAGE

POLARITY REPEAT MEASUREMENT, ANDRECORD RESULTS."

PAGE 3, PARA. 6.6: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING:

"THE AVERAGE TIME TO DECAY TO 10%OF THE MAX VOLTAGE SHALL BE INCLUDED FOR EACH OF THE WARP & FILLING DIRECTIONS, AS WELL AS THE OVERALL AVERAGE, FOR EACHFABRIC TESTED.

THESE WILL BE OBTAINED BY AVERAGING THE TEST RESULTS (ABSOLUTE VALUE OF) TOGETHER FOR BOTH VOLTAGEPOLARITIES. UNLESS OTHERWISE STATED IN THE REQUIREMENTS DOCUMENT, THE FABRIC SHALL BE CONSIDERED ACCEPTABLE IF THEAVERAGE MAXIMUM VOLTAGE IN BOTH THE WARP AND FILLING DIRECTIONS IS LESS THAN 4000 VOLTS, AND THE AVERAGE DECAY TIME (TO 10% MAXVOLTAGE) IS GREATER THAN 0.5 SECONDS IN BOTH THE WARP AND FILLING DIRECTIONS. IT

SHALL BE INDICATED WHETHER THE FABRIC ISACCEPTABLE OR NON-ACCEPTABLE."

PAGE 3, PARA. 7.1, SECOND COLUMN, LINE 2: DELETE 406C AND SUBSTITUTE WITH "406D".

AFTER PARA. 7.1, ADD THE FOLLOWING: "7.2 NOTE: IF THE MODEL 406D STATIC DECAY METER, OR EQUIVALENT, IS USED, A CHART RECORDER ISNOT MANDATORY FOR THE TEST."

(Ref. T0215)

INSPECTION OF SUPPLIES SHALL BE IN ACCORDANCE WITH FAR PART 52.246-2 STANDARD

INSPECTION.

ADDITIONAL INFORMATION FOR MIL-STD-105E:

MIL-STD-105E, dated 10 May 1989, is hereby canceled.

Future acquisitions may refer to: MIL-STD-1916, "DoD Preferred Methods for Acceptance of Product," or ANSI/ASQ Z1.4, "Sampling Procedures and Tables for Inspection by Attributes."

Users are cautioned to evaluate these documents for their particular application before citing it as a replacement document.

(Copies of MIL-STD-1916 are available online at http://assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)

(Copies of ANSI/ASQ Z1.4 are available online at www.asq.org or ASQ Distribution Center, 5131 S. Third Street, Milwaukee, Wisconsin 53207-6028.)

MIL-STD-147E

w/CHANGE 1 23 December 2013

SUPERSEDING

MIL-STD-147E

16 May 2008

DEPARTMENT OF DEFENSE

STANDARD PRACTICE

PALLETIZED UNIT LOADS

MIL-STD-129R W/CHANGE - DEPARTMENT OF DEFENSE STANDARD PRACTICE

MILITARY MARKING FOR SHIPMENT AND STORAGE

DATED 24 MAY 2018

INTERIM CHANGES:

OMISSION OF MARKINGS ON EXTERIOR SHIPPING CONTAINERS OF ITEMS

IN THE DLA TROOP SUPPORT CLOTHING AND TEXTILE (C&T) DIRECTORATE:

THE NOMENCLATURE AND MANUFACTURER'S NAME (WHEN THE NAME IDENTIFIES THE MATERIAL) SHALL

BE OMITTED FROM ALL EXTERIOR SHIPPING CONTAINERS OF DLA TROOP SUPPORT C&T ITEMS,

REGARDLESS OF MODE OF SHIPMENT.

IF THE MANUFACTURER'S NAME DOES NOT IDENTIFY THE MATERIAL AS BEING CLOTHING, IT MAY REMAIN. NSNS SHALL BE SHOWN ON ALL SHIPPING CONTAINERS OF C&T ITEMS, THE PACKING LIST SHALL BE PLACED INSIDE THE LAST CONTAINER TO BE LOADED FOR EACH SHIPMENT. THE WORDS

"PACKING LIST HERE" SHALL BE STENCILED, NOT HAND LETTERED, ON THE CONTAINER.

ADDITIONAL INFORMATION FOR MIL-STD-2073-1:

NO ADDITIONAL INFORMATION FOLLOWS

(Ref. T0898)

DELETE CURRENT "BARCODE LABEL/TAG" REQUIREMENTS AND SUBSTITUTE THE FOLLOWING:

LABEL TAG: EACH ITEM SHALL BE INDIVIDUALLY BAR-CODED WITH A PAPER TAG FOR PERSONAL CLOTHING ITEMS. THE PAPER USED FOR THE TAGS SHALL BE STANDARD BLEACHED SULFATE HAVING

A BASIS WEIGHT OF 100 POUNDS WITH A SMOOTH FINISH TO ACCEPT THERMAL TRANSFER AND

DIRECT PRINTING. THE TAGS SHALL HAVE A HOLE AND SHALL BE ATTACHED TO EACH ITEM BY A FASTENER, CLEARLY LEGIBLE AND READABLE BY SCANNER. THE BAR CODING ELEMENT SHALL BE A

13 DIGIT

NATIONAL STOCK NUMBER (NSN). THERE SHALL BE A 12 DIGIT UNIVERSAL PRODUCT CODE (UPC) ASSIGNED FOR ALL NSNS BY THE GOVERNMENT. THE INITIAL "UPC" MUST APPEAR BENEATH THE CODE. THE BAR CODES FOR NSN AND UPC SHALL BE A MEDIUM TO HIGH DENSITY AND SHALL BE LOCATED SO THAT THEY ARE COMPLETELY VISIBLE ON THE ITEM WHEN IT IS FOLDED AND PACKAGED

AS SPECIFIED. THE LABEL'S LOCATION SHALL CAUSE NO DAMAGE TO THE ITEM.

NOTE: UNIVERSAL PRODUCT CODE INFORMATION THE GOVERMENT ASSIGNED UNIVERSAL PRODUCT CODE

(UPC) MUST BE PLACED ON ALL SHIPPING CARTONS ON WHICH THE NSN APPEARS.

THE FOLLOWING DEFECTS APPLY FOR BARCODE LABELS/TAGS:

BAR CODE OMITTED OR NOT READABLE BY SCANNER

HUMAN-READABLE INTERPRETATION (HRI) OMITTED OR ILLEGIBLE

NOT VISIBLE ON FOLDED, PACKAGED ITEM CAUSES DAMAGE TO THE ITEM

NOTE: IF THE END ITEM IS PLACED IN A PLASTIC BAG - USE TYPE VII (PRESSURE SENSTIVE

LABEL) OF MIL-DTL-32075.

IF THE END ITEM IS TIED IN A BUNDLE OR LEFT AS AN INDIVIDUAL ITEM, USE TYPE VIII (TAG, PAPER) OF MIL-DTL-32075.

THE GOVERNMENT ASSIGNED UNIVERSAL PRODUCT

CODE (UPC) MUST BE PLACED ON ALL SHIPPING

PACKAGING INFORMATION

PGC 00312, PGC 02768

SHIPPING CONTAINER = ONE HUNDRED AND TWENTY (40 PACKAGES)

PRES/PACK LEVELS SHALL BE IN

ACCORDANCE WITH A-A-50013.

PALLETIZATION SHALL BE IN ACCORDANCE

WITH MIL-STD-147.

PACKING. ONE HUNDRED AND TWENTY (40 PACKAGES)

OF UNDERSHIRTS OF ONE SIZE IN A SHIPPING CARTON

THE SHIPPING CONTAINER SHALL BE A FIBERBOARD BOX

CONFORMING TO STYLE RSC-L, TYPE CF (VARIETY SW)

OR SF, CLASS DOMESTIC , GRADE 275 OF ASTM-D1974.

THE INSIDE OF EACH BOX SHALL BE FITTED WITH A

BOX LINER CONFORMING TO TYPE CF, CLASS DOMESTIC,

VARIETY DW, GRADE 275 OF ASTM-D1974. INSIDE

DIMENSIONS OF THE BOX SHALL; BE APPROXIMATELY

23-1/2 INCHES IN LENGTH, 15 INCHED IN WIDTH AND

15 INCHED IN DEPTH. EACH BOX SHALL BE CLOSED IN

ACCORDANCE WITH METHOD II AS SPECIFIED IN

ASTM-D1974. ALL SHIPPING CARTONS SHALL HAVE A

NSN AND UPC BAR CODE LABEL. MARKING OF CARTONS

AND SHIPPING LABELS SHALL BE IN ACCORDANCE WITH

MIL-STD-129. PALLETIZATION SHALL BE IN

ACCORDANCE WITH MIL-STD-147.

PGC 00036

SHIPPING CONTAINER = ONE HUNDRED AND TWENTY (60 PACKAGES)

PRES/PACK LEVELS SHALL BE IN

ACCORDANCE WITH A-A-50013.

PALLETIZATION SHALL BE IN ACCORDANCE

WITH MIL-STD-147.

PACKING. ONE HUNDRED AND TWENTY (60 PACKAGES)

OF UNDERSHIRTS OF ONE SIZE IN A SHIPPING CARTON

THE SHIPPING CONTAINER SHALL BE A FIBERBOARD BOX

CONFORMING TO STYLE RSC-L, TYPE CF (VARIETY SW)

OR SF, CLASS DOMESTIC , GRADE 275 OF ASTM-D1974.

THE INSIDE OF EACH BOX SHALL BE FITTED WITH A

BOX LINER CONFORMING TO TYPE CF, CLASS DOMESTIC,

VARIETY DW, GRADE 275 OF ASTM-D1974. INSIDE

DIMENSIONS OF THE BOX SHALL; BE APPROXIMATELY

23-1/2 INCHES IN LENGTH, 15 INCHED IN WIDTH AND

15 INCHED IN DEPTH. EACH BOX SHALL BE CLOSED IN

ACCORDANCE WITH METHOD II AS SPECIFIED IN

ASTM-D1974. ALL SHIPPING CARTONS SHALL HAVE A

NSN AND UPC BAR CODE LABEL. MARKING OF CARTONS

AND SHIPPING LABELS SHALL BE IN ACCORDANCE WITH

MIL-STD-129. PALLETIZATION SHALL BE IN

ACCORDANCE WITH MIL-STD-147.

252.211-7006 - RADIO FREQUENCY IDENTIFICATION (RFID) Required (ref. T8379; Nov. 08, 2006)

Packaging examination. The fully packaged end item shall be examined for the defects listed below. The lot size shall be expressed in units of shipping containers. The sample unit shall be one shipping container fully packaged. The Inspection level shall be S-2 and the AQL, expressed in terms of defects per hundred units, shall be 2.5.

Examine Defect

Marking Omitted; incorrect; illegible, of (exterior) improper size, location, sequence & Unit Pack, or method of application.

Materials Any component missing, damaged or not as specified.

Workmanship Inadequate application of components, such as: incomplete closure of container flaps, loose strapping, improper taping, or inadequate stapling. Bulged or distorted container.

Contents Number of intermediate containers per shipping container is more or less than required.

Number of items per container is more or less than required.

Palletization examination. The fully packaged and palletized end items shall be examined for the defects listed below. The lot size shall be expressed in units of palletized unit loads. The sample unit shall be one palletized unit load, fully packaged.

The Inspection level shall be S-1 and the AQL, expressed in terms of defects per hundred units, shall be 6.5.

Examine Defect

Finished Length, width or height exceeds Dimensions specified maximum requirement.

Palleti- Pallet pattern not as specified.

zation Interlocking of loads not as specified. Load not bonded with required straps as specified.

Weight Exceeds maximum load limits.

Marking Omitted; incorrect; illegible;

of improper size, location, sequence or method of appli-cation.

RFID HANGTAG:

An RFID inlay shall be added to the barcode paper hang tag attached to each item.

Where the use of self-adhesive bar-code labels are authorized, the RFID inlay may be added to the self-adhesive label in lieu of a paper hang tag. All other contract barcode and hang tag requirements still apply.

The RFID inlay should be passive Gen2 with a frequency range between 860 and 960 MHz.

The RFID antenna should be Avery/Dennis AD222 or comparable with ISO/IEC 18000-C EPCglobal C1G2 Protocol and an EPC memory allocation containing a 96 bit EPC Number.

The data linking the EPC number to the NSN and quantity unit pack must be exportable to VIM/ASAP. The bar code of the EPC Number must be printed at the bottom of the tag along with the human readable version below the bar code.

In addition to defects applicable to the paper tag and barcoding element, the RFID tag shall be examined for the defects listed below:

RFID Inlay omitted RFID Inlay not secure RFID Inlay not laying flat when packaged RFID Inlay not readable with RFID scanner RFID Inlay or configuration not as specified

The manual "Item-Level Passive RFID Technology Manufacturer's Information Guide" provides guidance on RFID implementation and is available from the contracting officer.

SIGNIFICANT NOTE - "PALLETIZATION IS REQUIRED FOR THESE SUPPLIES".

NOTE: THE FOLLOWING APPLIES TO ALL NON-MANUFACTURED WOOD PACKAGING MATERIALS:

"All Wood Packaging Material (WPM) acquired by DOD must meet requirements of International Standards for Phytosanitary Measures (ISPM) 15, "Guidelines for Regulating Wood Packaging Materials in International Trade." DOD shipments inside and outside of the United States must meet ISPM 15 whenever WPM is used to ship DOD cargo, or when wood is being acquired by DLA for future use as packaging material. WPM is defined as wood pallets, skids, load boards, pallet collars, wooden boxes, reels, dunnage, crates, frame and cleats. Packaging materials exempt from the requirements are materials that have undergone a manufacturing process, such as corrugated fiberboard, plywood, particleboard, veneer, and oriented strand board (OSD). All WPM shall comply with one of the following official quality control programs:

Heat Treatment (HT) or Kiln Dried Heat Treatment (KD HT) in accordance with American Lumber Standard Committee, Incorporated (ALSC) Wood Packaging Material Program and WPM Enforcement Regulations (see http://www.alsc.org/; or

All WPM shall include certification/quality markings in accordance with the ALSC or NWPCA standards, as applicable. Markings shall be placed in an unobstructed area that will be readily visible to inspectors. Pallet markings shall be applied to the stringer or block on diagonally opposite sides of the pallet and be contrasting and clearly visible.

All containers shall be marked on a side other than the top or bottom, contrasting and clearly visible. All dunnage used in configuring and/or securing the load shall also comply with ISPM 15 and be marked with an ASLC approved DUNNAGE stamp. Failure to comply with the requirements of this restriction may result in refusal, destruction, or treatment of materials at the point of entry. The Agency reserves the right to recoup from the Contractor any remediation costs incurred by the Government."

PALLET SHALL BE 4 WAY ENTRY, WINGED TYPE. PALLETIZED LOAD DIMENSIONS SHALL NOT EXCEED

43 INCHES IN LENGTH, 52 INCHES IN WIDTH, AND 54 INCHES IN HEIGHT (INCLUDING THE

PALLET).

THE PALLETIZED LOAD SHALL BE BONDED USING APPROVED COMMERCIAL BONDING MATERIALS. THE

USE OF METAL BANDING, IN SECURING BOXES TO PALLETS, IS DISCOURAGED. PALLET LOADS

SHALL CONTAIN THE SAME NUMBER OF CARTONS, OF IDENTICAL QUANTITIES, OF ONE NSN, TO THE

MAXIMUM EXTENT POSSIBLE.

PALLET LOADS CONTAINING MORE THAN ONE NSN SHALL BE CLEARLY MARKED TO LIST ALL THE NSN'S CONTAINED IN THE LOAD. NO CARTON SHALL HAVE MORE THAN ONE NSN. AT THE END OF A SIZE RUN, NO MORE THAN ONE CARTON PER NSN MAY BE SHORT OR OVER THE SPECIFIED QUANTITY.

SAID CARTON SHALL BE CLEARLY MARKED "SHORT" OR "OVER".

MIL-STD-147 IS REFERENCED FOR PALLETIZED LOADS.

IN ADDITION TO REQUIREMENTS SPECIFIED ABOVE THE FOLLOWING CLAUSE ALSO APPLIES:

52.247-9012 - REQUIREMENTS FOR TREATEMENT OF WOOD PACKAGING MATERIALS (WPM) - (JULY 2006)

File details come from the government source that posted it. Updated .