Permit_FDEP_Sewer.pdf
PDF 236 KB Posted
- Attached to
- Navarre Beach Event Hall and Boardwalk Complex
- Solicitation number
- 26-051
- Issued by
- Santa Rosa County, Mount Carmel CDP, Florida
About this file
This is a Florida Department of Environmental Protection (FDEP) permit approval letter issued to Navarre Beach Utilities for a domestic wastewater collection and transmission system project. The permit, numbered 0461594-001-DWC/CG, was issued on June 18, 2025, and is valid through June 17, 2030. The project involves the construction of approximately 300 linear feet of 8-inch PVC gravity sewer and two gravity manholes to serve a new restroom facility at the Navarre Beach Parking & Restroom-Turtle Center located at 8740 Gulf Boulevard in Navarre, Santa Rosa County, Florida. The proposed sewer system will connect to an existing manhole along the Gulf Boulevard right-of-way and ultimately discharge to the Navarre Beach Wastewater Treatment Facility (WWTF, Facility ID FL0023981). Construction specifications were certified by Richard Pfuntner, P.E., on May 27, 2025, and the notification application was received by FDEP on May 30, 2025, with fees paid on June 17, 2025.
The permit is subject to standard general permit conditions under Florida Administrative Code Rule 62-4.540 and does not relieve the permittee of responsibility for obtaining a dredge and fill permit if required. The permittee must submit a Notification of Completion of Construction (Form 62-604.300(3)(b)) electronically through the Florida DEP Business Portal before placing facilities into operation. All abnormal events, including spills exceeding 1,000 gallons, must be reported to the State Watch Office within 24 hours, with written submissions required within five days. Upon operational clearance, Navarre Beach Utilities must maintain the collection/transmission system to prevent sanitary sewer overflows, minimize infiltration and inflow, maintain an updated emergency response plan annually, and keep the approved Operation and Maintenance Manual available for inspection by FDEP personnel.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FLORIDA DEPARTMENT OF
Environmental Protection
Northwest District
160 W. Government St., Suite 308 Pensacola, FL 32502
Ron DeSantis Governor
Alexis A. Lambert
Secretary
June 18, 2025
NOTIFICATION OF ACCEPTANCE OF USE OF A GENERAL PERMIT
PERMITTEE: PERMIT NUMBER: 0461594-001-DWC/CG
Navarre Beach Utilities ISSUE DATE: June 18, 2025 By: Buddy Stephens, EXPIRATION DATE: June 17, 2030 Utilities Supervisor COUNTY: Santa Rosa 1411 Utility Drive PROJECT NAME: Navarre Beach Parking & Restroom- Navarre, FL 32566 Turtle Center buddys@santarosa.fl.gov WASTEWATER TREATMENT:
Navarre Beach WWTF
FACILITY ID: FL0023981
Dear Mr. Stephens:
This letter acknowledges receipt of your Notification/Application for Constructing a Domestic Wastewater Collection/Transmission System for the Navarre Beach Parking & Restroom-Turtle Center sewer project, Permit Number 0461594-001-DWC/CG. Our Office received the Notice on May 30, 2025 with fee payment received on June 17, 2025.
This is to advise you that the Department does not object to your use of such general permit.
The domestic wastewater collection/transmission system project as permitted will construct approximately 300 linear feet of 8-inch PVC gravity sewer and two gravity manholes. The project will serve a new restroom facility across Gulf Boulevard from the existing Sea Turtle Conservation Center.
The proposed 8-inch gravity sewer will connect to an existing manhole along the Gulf Boulevard right-of-way.
The wastewater from the project will eventually flow to the Navarre Beach WWTF, FL0023981, for treatment
The project development site is located at 8740 Gulf Boulevard in Navarre, Santa Rosa County, Florida
The construction shall be in accordance with the construction drawings certified by Richard Pfuntner, P.E., on May 27, 2025.
Please note the attached requirements apply to your use of this general permit for constructing the proposed domestic wastewater collection/transmission system.
mailto:buddys@santarosa.fl.gov
Navarre Beach Utilities PROJECT NAME: Navarre Beach Parking & Notification of Acceptance of Use of a General Permit Restroom -Turtle Center Page 2 of 5 PERMIT NUMBER: 0461594-001-DWC/CG
You are further advised that the construction activity must conform to the description contained in your Notification/Application for Constructing a Domestic Wastewater Collection/Transmission System and that any deviation will subject the permittee to enforcement action and possible penalties.
When referring to this project, please use the project name and file number indicated above. If you have any questions, please contact Tameasha Tisdale by phone at 850-595-0583 or by email at Tameasha.Tisdale@FloridaDEP.gov.
Sincerely, Maria Bertelli Engineering Specialist IV
Attachment:
Requirements for Use of the General Permit for Domestic Wastewater Collection/ Transmission Systems cc:
Richard Pfuntner, P.E., Dewberry Engineers, Inc. (rpfuntner@dewberry.com) Colby Brown, P.E., Project Manager, Dewberry Engineers, Inc. (csbrown@dewberry.com) Buddy Stephens, Utilities Supervisor, Navarre Beach Utilities (buddys@santarosa.fl.gov) Michael Schmidt, Public Works & Environmental Director, Santa Rosa County
(michaels@santarosa.fl.gov) Rebecca Jones, County Engineer, Santa Rosa County (rebeccaj@santarosa.fl.gov) Brad Baker, County Administrator, Santa Rosa County (bradb@santarosa.fl.gov) mailto:Tameasha.Tisdale@FloridaDEP.gov mailto:rpfuntner@dewberry.com mailto:csbrown@dewberry.com mailto:buddys@santarosa.fl.gov mailto:michaels@santarosa.fl.gov mailto:rebeccaj@santarosa.fl.gov mailto:bradb@santarosa.fl.gov
Page 3 of 5 PERMIT NUMBER: 0461594-001-DWC/CG
REQUIREMENTS FOR USE OF THE GENERAL PERMIT FOR DOMESTIC WASTEWATER
COLLECTION/TRANSMISSION SYSTEMS:
1. This general permit is subject to the general permit conditions of Rule 62-4.540, F.A.C., as applicable. [62-4.540]
2. This general permit does not relieve the permittee of the responsibility for obtaining a dredge and fill permit where it is required. [62-604.600(6)(b)1]
3. This general permit cannot be revised, except to transfer the permit. [62-604.600(6)(b)2]
4. This general permit will expire five years from the date of issuance. If the project has been started and not completed by that time, a new permit must be obtained before the expiration date in order to continue work on the project. [62-4.030]
5. Upon completion of construction of the collection/transmission system project, and before placing the facilities into operation for any purpose other than testing for leaks or testing equipment operation, the permittee shall submit Form 62-604.300(3)(b), Notification of Completion of Construction for a Domestic Wastewater Collection/Transmission System. The form shall be submitted electronically by using the Department’s Business Portal at https://www.fldepportal.com/go/ (via “Submit” then “Registration/Notification” and “Submit Notifications to DEP.” The submission is “Division of Water Resource Management Domestic/Industrial Wastewater” and the submittal type is “Notification of Completion of Construction for a Domestic Wastewater Collection/Transmission System.”). This form is available at the Department’s Internet site at: https://floridadep.gov/water/domestic-wastewater/content/domestic-wastewater-forms. [62-604.700(2)]
6. Abnormal events shall be reported to the Department’s Northwest District Office in accordance with
Rule 62-604.550, F.A.C. For unauthorized spills of wastewater in excess of 1000 gallons per incident, or where information indicates that public health or the environment may be endangered, oral reports shall be provided to the STATE WATCH OFFICE TOLL FREE NUMBER (800)320- 0519 as soon as practical, but no later than 24 hours from the time the permittee or other designee becomes aware of the circumstances. Unauthorized releases or spills less than 1000 gallons per incident are to be reported orally to the Department’s Northwest District Office within 24 hours from the time the permittee, or other designee becomes aware of the circumstances.
The oral notification shall be followed by a written submission, which shall be provided within five days of the time that the owner/operator becomes aware of the circumstances. The written submission shall contain: a description of the spill, release or abnormal event and its cause; the period and duration of noncompliance including exact dates and times, and if the noncompliance has not been corrected, the anticipated time it is expected to continue; clean-up actions taken and status;
steps taken or planned to reduce, eliminate, and prevent recurrence; the type of sanitary sewer overflow structure (e.g., manhole); the discharge location address and latitude/longitude; type of water discharged; discharge volumes and volumes recovered; volume discharged to surface waters and receiving waterbody name; types of human health and environmental impacts of the sanitary sewer overflow (e.g., beach closure); whether the noncompliance was caused by a third party (e.g., https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-4 https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-4 https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-604 https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-604 https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-4 https://floridadep.gov/water/domestic-wastewater/forms/notification-completion-construction-domestic-wastewater https://floridadep.gov/water/domestic-wastewater/forms/notification-completion-construction-domestic-wastewater https://floridadep.gov/water/domestic-wastewater/content/domestic-wastewater-forms https://floridadep.gov/water/domestic-wastewater/content/domestic-wastewater-forms https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-604
Page 4 of 5 PERMIT NUMBER: 0461594-001-DWC/CG contractor); and, whether the sanitary sewer overflow was related to wet weather. The written submission shall be provided electronically. Electronic submission is available using the Department’s Business Portal at https://www.fldepportal.com/go/ (via “Submit” followed by “Report” or “Registration/Notification”).
In accordance with Section 403.077, F.S., unauthorized releases or spills reportable to the State Watch Office shall also require a public notice of pollution report. Reporting may be made or by reporting electronically using the Department’s Business Portal at https://www.fldepportal.com/go/ (via “Submit” followed by “Report” or “Registration/Notification”) and selecting the option to also submit the public notice of pollution report, or reporting may be made to the Department’s Public Notice of Pollution web page at https://floridadep.gov/pollutionnotice. [62-604.550]
ADDITIONAL INFORMATION:
Once a collection/transmission system is cleared for operation, the provisions below shall be met by the owner/operator of the system in accordance with Rule 62-604.500, F.A.C.
1. All collection/transmission systems shall be operated and maintained to provide uninterrupted service. All pump stations shall be operated and maintained to provide the emergency pumping capability requirements in paragraph 62-604.400(2)(a), F.A.C., the lightning and transient voltage surge protections in paragraph 62-604.400(2)(b), F.A.C., and the design and signage requirements in paragraph 62-604.400(2)(d), F.A.C. Also, all equipment, pipes, manholes, pump stations, and other appurtenances necessary for the collection/transmission of domestic wastewater, including equipment provided pursuant to subsection 62-604.400(2), F.A.C., shall be maintained to function as intended. [62-604.500(2) and (3)]
2. The owner/operator of a collection/transmission system shall evaluate and update the emergency response plan portion of the operation and maintenance manual annually. The emergency response plan shall assess system security including cybersecurity; water quality monitoring for sanitary sewer overflows affecting surface waters; and, hurricane and severe storm preparedness and response. [62-604.500(4)]
3. Collection/transmission systems shall be maintained to minimize excessive infiltration and inflow into the collection/transmission system, as well as excessive leakage from the collection/transmission system. The owner/operator of a collection/transmission system shall take corrective actions when infiltration, inflow, or leakage is excessive. Infiltration and inflow are considered excessive if one or both cause or contribute to sanitary sewer overflows. Leakage, or exfiltration, is considered excessive if it causes or contributes to a violation of surface water quality standards or ground water quality standards. [62-604.500(5)]
4. All collection/transmission systems shall be operated and maintained to prevent sanitary sewer overflows. Owners/operators shall evaluate the cause of all sanitary sewer overflows and evaluate potential corrective measures to avoid future sanitary sewer overflows. Corrective actions shall be taken by the owner/operator of the collection/transmission system if excessive inflow and infiltration causes or contributes to a sanitary sewer overflow. The owner/operator of a satellite collection system shall take corrective actions for a sanitary sewer overflow in the receiving collection system caused by excessive inflow and infiltration in the satellite collection system. [62-604.500(6)] https://www.fldepportal.com/DepPortal/go/home https://www.fldepportal.com/DepPortal/go/home https://floridadep.gov/pollutionnotice https://floridadep.gov/pollutionnotice https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-604 https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-604 https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-604 https://www.flrules.org/gateway/ChapterHome.asp?Chapter=62-604
Page 5 of 5 PERMIT NUMBER: 0461594-001-DWC/CG
5. The approved Operation and Maintenance Manual and emergency response plan pursuant to Rule
62-604.500(4), F.A.C., shall be kept available at a site convenient for use by operation and maintenance personnel and for inspection by the Florida Department of Environmental Protection personnel.
File details come from the government source that posted it. Updated .