Pendleton Fire Station 2 CMGC RFP Addendum 1.pdf
PDF 2 MB Posted
- Solicitation number
- S-KN0040-00014158
- Issued by
- Union County, Oregon
About this file
Addendum 1 to the Request for Proposal (RFP) is issued by the City of Pendleton for a Construction Manager/General Contractor (CM/GC) project involving Fire Station 2 Seismic Rehabilitation. The addendum, dated June 26, 2025, modifies the original RFP documents from June 18, 2025, and includes two key attachments: a Mandatory Pre-Proposal Walkthrough Attendance List and a Conceptual Seismic Strengthening Scheme submitted as part of the Oregon SRGP application. Proposers are required to acknowledge receipt of this addendum on Attachment B – Certifications/Residency Form, with failure to do so potentially resulting in disqualification.
The addendum provides details about a mandatory pre-proposal walkthrough held on June 23, 2025, with attendees from several construction companies including Western Construction, CB Const, Inc., KC Industries, McCormick Const., Kirby Nagelhardt Construction Company, and Five Star Builders. The document indicates that all other requirements of the original RFP remain unchanged, suggesting this addendum is primarily informative and procedural in nature. The project involves seismic rehabilitation of the fire station, with detailed strengthening concepts outlined in the accompanying documentation, focusing on addressing structural and nonstructural deficiencies to improve the building's seismic performance.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pendleton Fire Station 2 Seismic Rehabilitation CMGC RFP.pdf | ||
| 2025-44 Notice of Intent to Award.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Request for Proposal (RFP)
City of Pendleton
Construction Manager/General Contractor (CM/GC)
Fire Station 2 Seismic Rehabilitation
Addendum 1
June 26, 2025
This addendum forms a part of the Request for Proposal and modifies the original Documents dated June 18, 2025, as noted below. Acknowledge receipt of this addendum in the space provided on Attachment B – Certifications / Residency Form. Failure to do so may subject the Proposer to disqualification.
ATTACHMENTS:
1. Mandatory Pre-Proposal Walkthrough Attendance List (For Information Only)
2. Conceptual seismic strengthening scheme submitted as part of the Oregon SRGP application
ALL OTHER REQUIREMENTS OF THE RFP SHALL REMAIN UNCHANGED.
END OF ADDENDUM 1
G1
COVER SHEET
SHEET
ID
G1
S1
S2
CITY OF PENDLETON FIRE STATION No. 2
SEISMIC REHABILITATION GRANT
STRENGTHENING CONCEPTS
PROJECT NARRATIVE
THE INTENT OF THESE DRAWINGS IS TO ILLUSTRATE THE SCHEMATIC SEISMIC REHABILITATION TASKS
TO RECTIFY THE LISTED SEISMIC AND NONSTRUCTURAL DEFICIENCIES. THESE SCHEMATIC DRAWINGS
HAVE BEEN PREPARED USING THE CURRENT OREGON STRUCTURAL SPECIALTY CODE (OSSC) AND
ASCE 41 (SEISMIC REHABILITATION OF EXISTING BUILDINGS) STANDARD.
THE TARGET FOR REHABILITATION IS TO ACHIEVE A LIFE SAFETY (LS) STRUCTURAL PERFORMANCE
LEVEL AND A HAZARDS REDUCED (HR) NONSTRUCTURAL PERFORMANCE LEVEL AT THE BSE-2E
SEISMIC EVENT AND THE IMMEDIATE OCCUPANCY (IO) STRUCTURAL PERFORMANCE LEVEL AND
POSITION RETENTION (PR) NONSTRUCTURAL PERFORMANCE LEVEL AT THE BSE-1E SEISMIC EVENT.
THE (IO) STRUCTURAL PERFORMANCE LEVEL MEANS THAT AFTER A DESIGN EARTHQUAKE, THE BASIC
VERTICAL AND LATERAL FORCE RESISTING SYSTEMS RETAIN NEARLY ALL OF THEIR PRE-EARTHQUAKE
STRENGTH AND STIFFNESS. VERY LIMITED DAMAGE TO BOTH THE STRUCTURAL AND NONSTRUCTURAL
COMPONENTS IS ANTICIPATED DURING THE DESIGN EARTHQUAKE WHICH REQUIRE SOME MINOR
REPAIRS, BUT MAY NOT BE REQUIRED PRIOR TO REOCCUPANCY. THE RISK OF LIFE THREATENING
INJURY AS A RESULT OF STRUCTURAL DAMAGE IS VERY LOW.
PROJECT INCLUDES SEISMIC REHABILITATION FOR THE ENTIRE FIRE STATION BUILDING.
STRUCTURAL DEFICIENCIES
S1. THE STRUCTURE DOES NOT CONTAIN A COMPLETE, WELL-DEFINED LOAD PATH WITH STRUCTURAL
ELEMENTS AND CONNECTIONS THAT SERVE TO TRANSFER INERTIAL FORCES ASSOCIATED WITH
MASS OF ELEMENTS TO THE BUILDING FOUNDATION.
S2. THE SHEAR STRESS IN THE UNREINFORCED MASONRY SHEAR WALLS IS MORE THAN 70 LB/IN.2 FOR
CONCRETE UNITS.
S3. EXTERIOR CONCRETE OR MASONRY WALLS THAT ARE DEPENDENT ON THE DIAPHRAGM FOR
LATERAL SUPPORT ARE NOT ANCHORED FOR OUT-OF-PLANE FORCES AT EACH DIAPHRAGM LEVEL
WITH STEEL ANCHORS, REINFORCING DOWELS, OR STRAPS THAT ARE DEVELOPED INTO THE
DIAPHRAGM.
S4. THE CONNECTIONS BETWEEN THE WALL PANELS AND THE DIAPHRAGM DOES INDUCE
CROSS-GRAIN BENDING OR TENSION IN THE WOOD LEDGERS.
S5. DIAPHRAGMS ARE NOT CONNECTED FOR TRANSFER OF SEISMIC FORCES TO THE SHEAR WALLS, AND THE CONNECTIONS ARE NOT ABLE TO DEVELOP THE LESSER OF THE SHEAR STRENGTH OF
WALLS OR DIAPHRAGMS.
S6. THE HEIGHT-TO-THICKNESS RATIO OF THE SHEAR WALLS IS GREATER THAN 13.
S7. THERE ARE NO CONTINUOUS CROSS TIES BETWEEN DIAPHRAGM CHORDS.
S8. ALL DIAGONALLY SHEATHED OR UNBLOCKED WOOD STRUCTURAL PANEL DIAPHRAGMS HAVE
HORIZONTAL SPANS GREATER THAN 30 FT AND ASPECT RATIOS GREATER THAN 3-TO-1.
S9. UNTOPPED METAL DECK DIAPHRAGMS OR METAL DECK DIAPHRAGMS WITH FILL OTHER THAN
CONCRETE CONSIST OF HORIZONTAL SPANS OF GREATER THAN 40 FT (12.2 M) AND HAVE ASPECT
RATIOS GREATER THAN 4-TO-1.
S10. ANCHORS OF CONCRETE OR MASONRY WALLS TO WOOD STRUCTURAL ELEMENTS ARE NOT
INSTALLED TAUT AND STIFF ENOUGH TO LIMIT THE RELATIVE MOVEMENT BETWEEN THE WALL AND
THE DIAPHRAGM BEFORE ENGAGEMENT OF THE ANCHORS.
NONSTRUCTURAL DEFICIENCIES (CONT.)
N5. THE TOPS OF GYPSUM BOARD PARTITIONS ARE LATERALLY SUPPORTED BY AN INTEGRATED
CEILING SYSTEM.
N6. THE TOPS OF CEILING-HIGH FRAMED OR PANELIZED PARTITIONS DO NOT HAVE LATERAL BRACING
TO THE STRUCTURE AT A SPACING EQUAL TO OR LESS THAN 6 FEET.
N7. INTEGRATED SUSPENDED CEILINGS ARE NOT RESTRAINED AT A SPACING LESS THAN 12 FT. WITH A
MINIMUM OF FOUR DIAGONAL WIRES AND COMPRESSION STRUTS.
N8. FREE EDGES OF INTEGRATED SUSPENDED CEILINGS DO NOT HAVE ENOUGH CLEARANCE.
STATE MAP
NORTH
SITE MAP/BUILDING PARTS IDENTIFICATION
NORTH
VICINITY MAP
NORTH
PROJECT LOCATION
S P r o j e c t s
P e n d l e t o n
F i r e
S t a t i o n
R G
P C
A D
G d w g
G
E T
V A
R
J O
B
N
U M
B E
R
P A
G E
F
E R
E N
C E
D A
T E
SHEET NO.
C I T
Y
O
F
P
E N
D L E
T O
N
F I R
E
S
T A
T I O
N
N o
S E
I S
M I C
H
A B
I L I T
A T
I O
N
G
R A
N T
R
E N
G T
H E
N I N
G
C
O N
C E
P T
S
S O
U
H
A T E
P E N
D L E T O
N
O
R
NONSTRUCTURAL DEFICIENCIES
N1. BREAKABLE CONTAINERS THAT HOLD HAZARDOUS MATERIALS, INCLUDING GAS CYLINDERS, ARE
NOT RESTRAINED BY LATCHED DOORS, SHELF LIPS, WIRES, OR OTHER METHODS.
N2. PIPING OR DUCTWORK CONVEYING HAZARDOUS MATERIALS IS NOT BRACED OR OTHERWISE
PROTECTED FROM DAMAGE THAT WOULD ALLOW HAZARDOUS MATERIAL RELEASE.
N3. PIPING CONTAINING HAZARDOUS MATERIAL, INCLUDING NATURAL GAS, DOES NOT HAVE SHUTOFF
VALVES OR OTHER DEVICES TO LIMIT SPILLS OR LEAKS.
N4. HAZARDOUS MATERIAL PIPING, INCLUDING NATURAL GAS PIPING, DOES NOT HAVE FLEXIBLE
COUPLINGS.
S3
PROJECT LOCATION
FOUNDATION AND FIRST FLOOR STRENGTHENING PLAN
SECOND FLOOR STRENGTHENING PLAN
ROOF STRENGTHENING PLAN
SHEET TITLE
SHEET INDEX
ALL NONSTRUCTURAL DEFICIENCIES WILL BE MITIGATED AS SHOWN
IN TABLE 4 IN THIS REPORT UNLESS SPECIFICALLY NOTED
OTHERWISE ON THE CONCEPTUAL STRENGTHENING SCHEME
DRAWINGS.
PENDLETON FIRE
STATION No. 2
N9. FREE EDGES OF INTEGRATED SUSPENDED CEILINGS ARE NOT SUPPORTED.
N10. LIGHT FIXTURES PENETRATING SUSPENDED CEILINGS ARE NOT SUPPORTED INDEPENDENT OF
THE GRID CEILING BY A MINIMUM OF TWO WIRES AT DIAGONALLY OPPOSITE CORNERS OF EACH
FIXTURE.
N11. LIGHT FIXTURES ON PENDANT SUPPORTS ARE NOT ATTACHED AT A SPACING EQUAL TO OR LESS
THAN 6 FEET AND DO NOT HAVE THE SPACE NEEDED TO MOVE WITHOUT CONTACTING ADJACENT
COMPONENTS IN THE EVENT OF AN EARTHQUAKE.
N12. LENS COVERS ARE NOT ATTACHED TO THE LIGHT FIXTURE WITH SAFETY DEVICES.
N13. GLAZING PANES LARGER THAN 16FT
ARE NOT MADE OF LAMINATED ANNEALED OR LAMINATED
HEAT-STRENGTHENED GLASS.
N14. CONTENTS MORE THAN 6 FT. HIGH WITH A HEIGHT-TO-DEPTH RATIO GREATER THAN 3-TO-1 ARE
NOT ANCHORED TO THE STRUCTURE OR TO EACH OTHER.
N15. CONTENT WEIGHING MORE THAN 20 LB. WHOSE CENTER OF MASS IS MORE THAN 4 FT. ABOVE THE
ADJACENT FLOOR LEVEL ARE NOT BRACED OR OTHERWISE RESTRAINED.
N16. EQUIPMENT MORE THAN 6 FT. HIGH WITH A HEIGHT-TO-DEPTH OR HEIGHT-TO-WIDTH RATIO
GREATER THAN 3-TO-1 IS NOT ANCHORED TO THE FLOOR SLAB OR ADJACENT STRUCTURAL
WALLS.
N17. MECHANICALLY OPERATED DOORS ARE NOT DETAILED TO OPERATE AT A STORY DRIFT RATIO OF
0.01.
N18. EQUIPMENT SUSPENDED WITHOUT LATERAL BRACING IS NOT FREE TO SWING FROM OR MOVE
WITH THE STRUCTURE FROM WHICH IT IS SUSPENDED WITHOUT DAMAGING ITSELF OR ADJOINING
COMPONENTS.
N19. FLOOR-SUPPORTED EQUIPMENT WEIGHING MORE THAN 400 LB. IS NOT ANCHORED TO THE
STRUCTURE.
N20. FLUID AND GAS PIPING DOES NOT HAVE FLEXIBLE COUPLINGS.
N21. FLUID AND GAS PIPING ARE NOT ANCHORED AND BRACED TO THE STRUCTURE TO LIMIT SPILLS
OR LEAKS.
S1
SCALE:
FOUNDATION AND FIRST FLOOR STRENGTHENING PLAN
NTS
NORTH
P W
K
P e n d l e t o n
F i a t i o n
N o
G
P C
A D
S d
U
S E
R
J O
B
N
U M
B E
R
P A
F
E R
E N
C E
D A
T E
SHEET NO.
C I T
Y
O
F
P
E N
D L E
T O
N
F I R
E
S
T A
T I O
N
N o
S E
I S
M
H
A B
I L I T
A T
I O
N
G
R A
R
E N
G T
H E
N I N
G
C
O N
C E
P T
S
S O
U
T E
P E N
D L E T O
N
O
R
ADD CONCRETE SHEAR WALL TO EXTERIOR FACE W/ ADHESIVE DOWELS TO (E)
URM WALL. ADD WEATHER PROTECTION AS REQUIRED.(S1, S2)
ADD PLYWOOD TO (E) STUD WALL BELOW 2ND FLOOR ONLY. REPAIR FLOOR,
WALL AND CEILING FINISHES AS REQUIRED. REMOVE AND INSTALL IMPACTED
CASEWORK AND PLUMBING/LIGHTING FIXTURES. (S1)
ADD HSS STRONGBACKS FOR OUT-OF-PLANE WALL BRACING AT URM WALLS AS
SHOWN. ADD WEATHER PROTECTION AS REQUIRED. (S6)
ADD 2'-0" WIDE X 2'-6" THICK FOOTING FOR SHEAR WALLS AND STRONGBACKS
AS SHOWN. REPAIR FLOOR FINISHES AS REQUIRED (S1)
REPLACE APPARATUS BAY DOORS TO ACCOMMODATE STORY DRIFT OF 0.01
(N17)
KEYED NOTES
NOTE:
INDICATES (E) URM WALL
S2
P W
P e n d l e t o n
F i a t i o n
N o
G
P C
A D
S d
U
S E
R
J O
B
N
U M
B E
R
P A
F
E R
E N
C E
D A
T E
SHEET NO.
C I T
Y
O
F
P
E N
D L E
T O
N
F I R
E
S
T A
T I O
N
N o
S E
I S
M
H
A B
I L I T
A T
I O
N
G
R A
R
E N
G T
H E
N I N
G
C
O N
C E
P T
S
S O
U
T E
P E N
D L E T O
N
O
R
SCALE:
SECOND FLOOR STRENGTHENING PLAN
NTS
NORTH
STAIR
OPENING
ADD OUT-OF-PLANE WALL ANCHORS AT 4'-0" OC AT (E) WOOD LEDGER TO
ELIMINATE CROSS-GRAIN BENDING. (S3, S4)
ADD BLOCKING TO (E) PLYWOOD DIAPHRAGM. REPAIR CEILING/FLOOR
FINISHES AS REQUIRED. (S8)
ADD IN-PLANE CONNECTION BETWEEN DIAPHRAGM AND SHEAR WALL.
REPAIR CEILING/FLOOR FINISHES AS REQUIRED. (S1, S5)
ADD METAL STRAPPING TO REINFORCE FLOOR DIAPHRAGM STAIRWELL
OPENING. REPAIR FLOOR FINISHES AS REQUIRED. (S1)
KEYED NOTES
NOTE:
INDICATES (E) URM WALL
(E
2X F
LO
O
R J
O
IS
T
NOT ALL OUT-OF-PLANE
ANCHORS SHOWN FOR CLARITY
NOTE:
6'-0"
S3
P W
P e n d l e t o n
F i a t i o n
N o
G
P C
A D
S d
U
S E
R
J O
B
N
U M
B E
R
P A
F
E R
E N
C E
D A
T E
SHEET NO.
C I T
Y
O
F
P
E N
D L E
T O
N
F I R
E
S
T A
T I O
N
N o
S E
I S
M
H
A B
I L I T
A T
I O
N
G
R A
R
E N
G T
H E
N I N
G
C
O N
C E
P T
S
S O
U
T E
P E N
D L E T O
N
O
R
SCALE:
ROOF STRENGTHENING PLAN
NTS
NORTH
3 3
ADD OUT-OF-PLANE WALL ANCHORS AT (E) URM WALLS AT 4'-0" OC. REPAIR
CEILING FINISHES AS REQUIRED. (S3, S10)
ADD IN-PLANE CONNECTION BETWEEN DIAPHRAGM AND DIAPHRAGM
COLLECTOR. (S5)
ADD CROSS-TIES AT 16 FT OC FOR SUBDIAPHRAGM ANCHORAGE. (S7)
ADD 18 GA METAL DECK W/ SIDE SEAM CONNECTIONS AT 18" OC.
STRENGTHEN ROOF FRAMING AS REQUIRED. REMOVE AND REPLACE
ROOFING AS REQUIRED. (S9)
ADD STEEL COLLECTOR AT ROOF DIAPHRAGM TO DELIVER LOAD INTO
CONCRETE SHEAR WALL. REPAIR SOFFIT FINISHES AS REQUIRED. (S5)
KEYED NOTES
(E
S T
L G
IR
D
E R
(E
S T
L G
IR
D
E R
(E
S T
L G
IR
D
E R
(E
S T
L G
IR
D
E R
(E) ROOF PURLINS AT 5'-0" O.C. (E) ROOF PURLINS AT 5'-0" O.C. (E) ROOF PURLINS AT 5'-0" O.C.
(E) SKYLIGHT TO
BE REMOVED, TYP
6'-0"
NOTE:
NOT ALL OUT-OF-PLANE ANCHORS
SHOWN FOR CLARITY
File details come from the government source that posted it. Updated .