Pedestrian_Guardrail_-_Plans.pdf

PDF 7 MB Posted

Attached to
2025 Pedestrian Guardrail Replacement Project - Capitola Road & East Cliff Drive
Solicitation number
IFB No. PW-0284
Issued by
Santa Cruz County, San Francisco City, California

About this file

This is a design plans document for the Santa Cruz Public Works Department's 2025 Pedestrian Guardrail Replacement Project, located in Capitola, California. The project scope encompasses the removal and replacement of damaged pedestrian guardrails at two locations: Capitola Road and East Cliff Drive. At Capitola Road, approximately 68 linear feet of damaged pedestrian guardrail requires removal and replacement conforming to existing guardrail specifications, along with removal of a damaged retaining wall and its replacement with poured concrete concrete (PCC). At East Cliff Drive, approximately 18 linear feet of damaged pedestrian guardrail requires similar removal and replacement. The design plans include construction details specifying guardrail fabrication requirements, including galvanized 12-inch diameter steel pipe posts and 4-inch standard weight steel pipe components, welded connections, and integration with existing curbs and concrete pavement. All guardrails must be galvanized after fabrication, and contractors are required to verify exact dimensions prior to fabrication.

The project plans indicate that contractors must furnish all labor, materials, tools, equipment, and transportation necessary for project completion. The document reflects a design date of February 24, 2026, with California registered professional engineer stamp number C 088069 expiring March 31, 2026. The detailed specifications address connection points to existing guardrails that will remain in place, proper doweling of new concrete into existing walls and curbs, and conformance to Caltrans Type 6B split-face concrete block retaining wall standards and Type B3 curb specifications. No specific pricing, bid timeline, award date, or contract term information is contained within these design plans.

View the file

Other files

File Type Posted
Pedestrian_Guardrail_-_Specifications.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESIGN

CHECKED

DATE

DRAWN

SCALE

OF

SHEET

VAULT NO.

809 Center Street, Room 201

Santa Cruz, CA 95060

P U B L I C W O R K S D E P A R T M E N T

2025 PEDESTRIAN GUARDRAIL REPLACEMENT PROJECT

TITLE SHEET

NO SCALE02/24/2026

DnCabreros

DEstranero

DnCabreros

SHEET NAME

1 TITLE SHEET

2 CAPITOLA ROAD

3 E CLIFF DRIVE

4 DETAIL SHEET 1

5 DETAIL SHEET 2

P U B L I C W O R K S D E P A R T M E N T

2025 PEDESTRIAN GUARDRAIL REPLACEMENT PROJECT

PROJECT LOCATION

(CAPITOLA ROAD)

PROJECT LOCATION

(E CLIFF DRIVE)

I A

RE

EN

I

GN

E L

V I LIC

ACF FIL OR

NSEF IS O

N

A

ETA

RP

E

TS

I G E R

ETS

R

D

O

O

No. C 088069

EXP. 3/31/26

CAPITOLA ROAD AND EAST CLIFF DRIVE

CAPITOLA RD

H

AR

BO

R

VIEW

C T

DESIGN

CHECKED

DATE

DRAWN

SCALE

OF

SHEET

VAULT NO.

809 Center Street, Room 201

Santa Cruz, CA 95060

P U B L I C W O R K S D E P A R T M E N T

2025 PEDESTRIAN GUARDRAIL REPLACEMENT PROJECT

CAPITOLA ROAD

NO SCALE02/24/2026

DnCabreros

DEstranero

DnCabreros

REMOVE AND REPLACE DAMAGED PEDESTRIAN GUARDRAIL (APPROX. 68')

CONFORM TO EXISTING GUARDRAIL

REMOVE DAMAGED RETAINING WALL AND REPLACE WITH PCC CONCRETE

SEE DETAIL SHEET 4

SECTION A-A

NOT TO SCALE

A

A

CONNECTION POINTS

(E) GAUARDRAIL

TO REMAIN

(E) GAUARDRAIL

TO REMAIN

DAMAGED RETAINING

WALL LOCATION

I A

RE

EN

I

GN

E L

V I LIC

ACF FIL OR

NSEF IS O

N

A

ETA

RP

E

TS

I G E R

ETS

R

D

O

O

No. C 088069

DATE

DRAWN

SCALE

OF

SHEET

VAULT NO.

809 Center Street, Room 201

Santa Cruz, CA 95060

P U B L I C W O R K S D E P A R T M E N T

2025 PEDESTRIAN GUARDRAIL REPLACEMENT PROJECT

EAST CLIFF DRIVE

NO SCALE02/24/2026

DnCabreros

DEstranero

DnCabreros

REMOVE AND REPLACE DAMAGED PEDESTRIAN GUARDRAIL (APPROX. 18')

CONFORM TO EXISTING GUARDRAIL

SEE DETAIL ON SHEET 5

CONNECTION POINTS CONNECTION POINTS

(E) GAUARDRAIL

TO REMAIN

(E) GAUARDRAIL

TO REMAIN

I A

RE

EN

I

GN

E L

V I LIC

ACF FIL OR

NSEF IS O

N

A

ETA

RP

E

TS

I G E R

ETS

R

D

O

O

DATE

DRAWN

SCALE

OF

SHEET

VAULT NO.

809 Center Street, Room 201

Santa Cruz, CA 95060

P U B L I C W O R K S D E P A R T M E N T

2025 PEDESTRIAN GUARDRAIL REPLACEMENT PROJECT

DETAIL SHEET 1

NO SCALE02/24/2026

DnCabreros

DEstranero

DnCabreros

NOTES:

1. CONTRACTOR MUST VERIFY THE EXACT DIMENSIONS OF GUARDRAILS PRIOR TO FABRICATION.

2. GALVANIZED GUARDRAILS AFTER FABRICATION

3. REMOVE DAMAGED GUARDRAIL AND DAMAGED POST

4. DAMAGED BLOCK RETAINING WALL SHALL BE REMOVE AND REPLACE WITH PCC CONCRETE DOWELED INTO (E) WALL.

(SEE DETAIL ABOVE)

CONSTRUCTION DETAIL

FOR ILLUSTRATION ONLY

6' MAX

18"

1 12" DIA PIPE GALVANIZED

AFTER FABRICATION

WELD (TYP)

12"

4"

(E) CALTRANS TYPE 6B SPLIT FACE

CONCRETE BLOCK RETAINING

WALL AT BACK OF SIDEWALK

4" (TYP)

4" (TYP)

REMOVE DAMAGED RETAINING

WALL. INSTALL (N) PCC

CONCRETE

REMOVE RETAINING WALL.

INSTALL (N) PCC CONCRETE

(TYP AT POLE LOCATIONS)

(N) #4 BARS

16"

(N) #4 BARS

(E) SIDEWALK

DAMAGED RETAINING

WALL LOCATION

12"

8"

24"

MATCH (E) PEDESTRIAN

GUARDRAIL SLOPE

I A

RE

EN

I

GN

E L

V I LIC

ACF FIL OR

NSEF IS O

N

A

ETA

RP

E

TS

I G E R

ETS

R

D

O

O

DATE

DRAWN

SCALE

OF

SHEET

VAULT NO.

809 Center Street, Room 201

Santa Cruz, CA 95060

P U B L I C W O R K S D E P A R T M E N T

2025 PEDESTRIAN GUARDRAIL REPLACEMENT PROJECT

DETAIL SHEET 2

NO SCALE02/24/2026

DnCabreros

DEstranero

DnCabreros

NOTES:

1. CONTRACTOR MUST VERIFY THE EXACT DIMENSIONS OF

GUARDRAILS PRIOR TO FABRICATION.

2. GALVANIZED GUARDRAILS AFTER FABRICATION

42"

10' MAX 2 12" STANDARD WEIGHT

STEEL PIPE. GALVANIZED

AFTER FABRICATION

4" STANDARD WEIGHT

STEEL PIPE (TYP).

GALVANIZED AFTER

FABRICATION

WELD (TYP)

6" (TYP)

24" (N) TYPE B3

CURB TO MATCH

EXISTING

(E) TYPE B3

CALTRANS CURB

(E) GUARDRAIL

(N) GUARDRAIL

10"

36"

18" #4 REBAR

DOWELED 4" INTO

(E) CURB

8" #4 REBAR DOWELED

4" INTO (E) CONCRETE

PAVEMENT

(E) SHOTCRETE WALL

GUARDRAIL

TYPE B3

CALTRANS CURB

(E) TYPE B3

CALTRANS CURB

6"

(E) 3" CONCRETE

PAVEMENT

(E) 9" AB

10"

36"

TYPE B3 CURB DETAIL

NOT TO SCALE

5"

5"

8 12"

3 12"

6"

#4 REBARS

I A

RE

EN

I

GN

E L

V I LIC

ACF FIL OR

NSEF IS O

N

A

ETA

RP

E

TS

I G E R

ETS

R

D

O

O

Sheets and Views
Pedestrian Rail Repair-TITLE
Pedestrian Rail Repair-Capitola
Pedestrian Rail Repair-ECliff
Pedestrian Rail Repair-Detail-Capitola
Pedestrian Rail Repair-Detail-ECliff

File details come from the government source that posted it. Updated .