PDX 2026-512 (68) E2.741.pdf
PDF 851 KB Posted
- Solicitation number
- 146219
- Issued by
- Multnomah County, Oregon
About this file
This is a reflected ceiling plan for electrical systems prepared for Portland International Airport's Terminal and Concourses Wayfinding Signage project (PDX 2026-512). The document, drawn by PAE Engineers and dated August 2026, provides detailed specifications for the Terminal Enplaning Sector 41 electrical infrastructure supporting new wayfinding signage installation. The plan includes keynotes and notes addressing sign connections to existing circuits, DMX channel designations for the ETC DMX controller system, daisy-chain DMX cable routing between signs, and the 4-channel ETC Gateway located in the concourse. All new or extended circuits require concealed conduit with patching and painting as required, and suspended signage cable routing must follow the typical detail specified on drawing E5.001. The electrical plan is scaled at 1/8" = 1'-0" and shows the layout of electrical connections, circuit feeds, and control systems necessary for the wayfinding signage installation.
The document serves as a technical construction drawing rather than a procurement specification document and does not contain pricing information, set-asides, contract terms, funding sources, or award dates. The plan was prepared under project number 26-1037 and is part of the comprehensive wayfinding signage MEP (Mechanical, Electrical, Plumbing) design set for Portland International Airport. The drawing includes standard notation regarding reduced-scale printing at 50% for 17" x 22" sheet sizes and references to related demolition plans and floor plans for complete project context.
View the file
Other files
Show 40 more
Latest 50 of 248 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D1
CE'
C01
CA'
CB'
CA
CB
CC
CD
CD'
CE
C02C03C04C05C06C07
2' 2'CE 3'
AF
AG
BA
AH
BB
BC
AJ
T17 T16T18T19 T15
TC
TB
BC'
TA.9
TB.1
TB.2
TB.3
TB.6
TC.8
PB1
N
FM3
N
2P3C-7CA: 18
DMX1C-27E-DIN-A:CH3
4L3C-7CA:2.
M A
T C
H L
IN
E
S E
E S
H E
E T
E .7
N
KEY PLAN
SCALE: N.T.S.
/4
/2
G R
A P
H
IC
S C
A L E
-F O
R R
E F
E R
E N
C E
O N
L Y
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".
SUBMITTED BY
DESIGNED BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
DRAWING NO.
TYPE
DISC. SHT. NO.
EAN PAN
NO. DATE BY REVISIONS
A
PP
C A
N Y
O U
S E
E T
H E
A
IR
P L A
N E
S
T
H E
A D
J A
C E
N T
S A
M P
L E
S S
H O
W T
H R
E E
D
IF
F E
R E
N T
L E
V E
L S
O F
S H
A D
IN
G
S
E T
T
IN
G S
F O
R V
IE
W
IN
G
A N
D P
R
IN
T
IN
G D
R A
W
IN
G C
O N
T E
N T
A R
E O
P T
IM
IZ
E D
W H
E N
A L L T
H R
E E
P L A
N E
S A
R E
V
IS
IB
L E
T
H
IS
G U
ID
A
N C
E I S
P R
O V
ID
E
D F
O R
R E
F E
R E
N C
E O
N L Y b la c k g ra y g ra y lig h t d a rk
NO. DATE BY REVISIONS
A
PP
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING
TYPE
D R
A W
IN
G
S C
A L E
I S
R E
D U
C E
D
W H
E N
S H
E E
T S
IZ
E
I S x
B▲ A▲
151 SW 1st Avenue #300 Portland, OR 97204
503.226.2921 pae-engineers.com
7/24/2026 8:52:32 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/26-1037 - PDX Wayfinding MEP25.rvt
TERMINAL - ENPLANING - SECTOR 41 - REFLECTED CEILING PLAN - ELECTRICAL
PORTLAND INTERNATIONAL AIRPORT
E2.741
AUGUST 2026
G. PARTHEMER
P. MARKS
D. PEEK
JAY OSTLUND
TERMINAL AND CONCOURSES WAYFINDING SIGNAGE
PDX 2026-512
CD
1031012026D004
N
SCALE: 1/8" = 1'-0"
TERMINAL - ENPLANING - SECTOR 41 - REFLECTED CEILING PLAN - ELECTRICAL
KEYNOTE(S) :
1. CONNECT NEW SIGN TO EXISTING
CIRCUIT.
2. CONNECT NEW GATE SIGN TO
EXISTING CIRCUIT.
3. CONNECTION THROUGH GREENGATE
RELAY PANEL TO BE ELIMINATED.
RECONNECT LOAD-SIDE WIRING TO
PANELBOARD BREAKER SHOWN. SEE
DEMOLITION PLAN, THIS SECTOR FOR
ADDITIONAL INFORMATION.
24'16'8'4'0'
SCALE: IN FEET
NOTE(S):
1. AT SIGNS SHOWN WITH DMX CHANNEL
DESIGNATION, CONNECT UN-SWITCHED
LINE VOLTAGE TO ETC DMX
CONTROLLER FURNISHED WITH SIGN
UNLESS OTHERWISE NOTED.
2. AT SIGNS SHOWN WITH DMX CHANNEL
DESIGNATION, CONNECT NEW DMX
CABLE TO ETC DMX CONTROLLER
FURNISHED WITH SIGN.
3. DAISY CHAIN DMX CABLE BETWEEN
SIGNS FROM 4 CHANNEL ETC GATEWAY
IN THIS CONCOURSE. CONNECT TO ETC
UNISON FOUNDRY 0-10V CONTROLLER
PROVIDED WITH SIGN AND EXTEND
0-10V WIRING TO SIGN DRIVERS. SEE
FLOOR PLANS FOR GATEWAY
LOCATION AND SPECIFICATIONS FOR
CABLE AND CONDUIT REQUIREMENTS.
ROUTE ALL DMX CIRCUITS CONCEALED
EXCEPT WHERE EXTENDING OUT TO
SUSPENDED SIGNS.
4. WHERE NEW OR EXTENDED CIRCUITS
ARE REQUIRED, CONCEAL CONDUIT
AND PROVIDE PATCHING AND PAINTING
AS REQUIRED.
5. REFER TO TYPICAL CABLE ROUTING
DETAIL ON E5.001 FOR SUSPENDED
SIGNAGE.
L
R E
N
G
O
R
I
E
I
S
ST
S
E
E
N
ER
F
E
E
G
OD R
N
EXPIRES: 12/31/2026
P
A
I
44775PE
OREGONJ
U L Y 13 , 19 9
9G R
A
NT R. PA RTHEM
E R
07/24/26
| 2026-07-24T10:10:20-0700 | |
| Grant Parthemer | |
| I am approving this document. |
File details come from the government source that posted it. Updated .