This is a technical drawing specification document for Portland International Airport's Terminal and Concourses Wayfinding Signage project in Oregon. The drawing details sign specifications for the CMB2 (Concourse B, C, D, and E wayfinding system), which consists of four 1-foot by 13-foot by 3.5-inch illuminated sign cabinets manufactured by Signcomp with soft aluminum frames painted Port White. The signage features white translucent fabric substrates with direct-printed graphics using UV inks, incorporating back-illumination through LED modules at 6700K for cabinet illumination and 6500K for light bars. The sign faces display wayfinding information for gates D10-D15, ticketing, ground transportation, restrooms, baggage claim, and various concourse locations. Visible sign dimensions are 12 feet 11 inches wide by 11.25 inches high, with overall printed fabric measuring 13 feet 2 inches wide by 1 foot 2 inches high. The design specifications include Helvetica Neue LT Standard Light font with 4-inch cap height, color matching to specific Pantone standards (2955 for background, 7462 for copy and graphics, and 2379 for graphic container strokes), and precise alignment marks for installation accuracy.

The signage system requires electrical connections with 20-amp rated power circuits at 120/277V AC and integration with the airport's lighting controller for dimmable LED functionality. Incoming wiring is specified to be provided by the Division 26 electrical contractor, with the sign manufacturer responsible for locating and providing necessary devices. The mounting system accommodates variable ceiling heights through adjustable vertical mounting supports, with electrical connections to structural supports and detailed fabrication specifications referenced on related drawing sheets G9.103, G9.104, and G9.105. The document is dated August 2026 and indicates this is a re-bid project for Portland International Airport's comprehensive wayfinding signage installation across terminal and concourse areas.

View the file

Other files

File Type Posted
PDX 2026-512 (17) S2.253.pdf PDF
PDX 2026-512 (181) G2.273.pdf PDF
PDX 2026-512 (08) S0.003.pdf PDF
PDX 2026-512 (85) E9.004.pdf PDF
PDX 2026-512 (174) G2.260.pdf PDF
PDX 2026-512 (128) G2.071.pdf PDF
PDX 2026-512 (39) E0.002.pdf PDF
PDX 2026-512 (95) T2.200.pdf PDF
PDX 2026-512 (67) E2.740.pdf PDF
PDX 2026-512 (159) G2.202.pdf PDF
PDX 2026-512 (222) G9.117.pdf PDF
PDX 2026-512 (139) G2.131.pdf PDF
PDX 2026-512 (96) T2.252.pdf PDF
PDX 2026-512 (28) S2.370.pdf PDF
PDX 2026-512 (163) G2.221.pdf PDF
PDX 2026-512 (148) G2.153.pdf PDF
PDX 2026-512 (18) S2.270.pdf PDF
PDX 2026-512 (103) G0.002.pdf PDF
PDX 2026-512 (43) E1.200.pdf PDF
PDX 2026-512 (93) T2.153.pdf PDF
PDX 2026-512 (115) G2.025.pdf PDF
PDX 2026-512 (145) G2.143.pdf PDF
PDX 2026-512 (229) G9.124.pdf PDF
PDX 2026-512 (122) G2.053.pdf PDF
PDX 2026-512 (197) G2.371.pdf PDF
PDX 2026-512 (65) E2.700.pdf PDF
PDX 2026-512 (241) G9.136.pdf PDF
PDX 2026-512 (164) G2.222.pdf PDF
PDX 2026-512 (179) G2.271.pdf PDF
PDX 2026-512 (149) G2.160.pdf PDF
PDX 2026-512 (196) G2.363.pdf PDF
PDX 2026-512 (165) G2.231.pdf PDF
PDX 2026-512 (202) G2.442.pdf PDF
PDX 2026-512 (146) G2.151.pdf PDF
PDX 2026-512 (177) G2.263.pdf PDF
PDX 2026-512 (240) G9.135.pdf PDF
PDX 2026-512 (140) G2.131.pdf PDF
PDX 2026-512 (31) S2.373.pdf PDF
PDX 2026-512 (73) E2.771.pdf PDF
PDX 2026-512 (75) E2.773.pdf PDF
PDX 2026-512 (238) G9.133.pdf PDF
PDX 2026-512 (05) GI4.000.pdf PDF
PDX 2026-512 (198) G2.372.pdf PDF
PDX 2026-512 (214) G9.109.pdf PDF
Substitution Request Form.pdf PDF
PDX 2026-512 (162) G2.212.pdf PDF
PDX 2026-512 (201) G2.431.pdf PDF
PDX 2026-512 (0) Re-Bid COVER.pdf PDF
PDX 2026-512 (168) G2.241.pdf PDF
PDX 2026-512 (225) G9.120.pdf PDF
Show 40 more

Latest 50 of 248 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/

4" 1/

2" 1"

2"

G R

AP

H

IC

S

C

AL

E-

FO

R R

EF

ER

EN

C

E O

N

LY

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS APP

C

AN

Y O

U S

EE

T

H E

AI

R

PL

AN

ES

T H

E

AD

JA

C

EN

T

SA

M

PL

ES

S H

O W

T H

R

EE

D

IF

FE

R

EN

T

LE

VE

LS

O

F

SH

AD

IN

G

SE

TT

IN

G

S

FO

R V

IE

W

IN

G

A N

D P

R

IN

TI

N

G D

R

AW

IN

G

C O

N

TE

N T

AR

E

O

PT

IM

IZ

ED

W

H

EN

A

LL

T H

R

EE

P

LA

N

ES

A R

E

VI

SI

BL

E.

T

H

IS

G U

ID

AN

C E

IS

P

R O

VI

D

ED

F

O R

R

EF

ER

EN

C E

O N

LY

bl ac k gr ay gr ay lig ht da rk

NO. DATE BY REVISIONS APP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

AW

IN

G S

C

AL

E

IS

R

ED

U C

ED

0% W

H

EN

S H

EE

T

SI

ZE

IS

7" x

2"

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:08:13 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

SIGN DETAILS 10

PORTLAND INTERNATIONAL AIRPORT

G9.110

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

CMB2 - SECTION

SCALE: 1" = 1' - 0"

LE

N

G

TH

O F

V

ER

TI

C

A L

M O

U N

TI

N

G S

U

PP

O R

T

VA

R

IE

S D

EP

EN

D

IN

G O

N C

EI

LI

N G

H

EI

G H

T

ELECTRICAL

CONNECTION TO STRUCTURAL SUPPORT

VARIES PER LOCATION, SEE STRUCTURAL

POWER SUPPLY: CONFIRM COMPATIBILITY

WITH AIRPORT MANAGEMENT SYSTEM.

POWER SUPPLY TO BE LOCATED IN TOP

CABINET (PER SIDE)

CABINET ILLUMINATION: LED 6700K MODULES,

DIMMABLE AND CONNECTED TO LIGHTING

CONTROLLER

INNER MOUNTING PLATE

LIGHT BAR ILLUMINATION: LED PRISM

6500K WHITE MODULES, DIMMABLE AND

CONNECTED TO LIGHTING CONTROLLER

HORIZONTAL ALUMINUM PIPE

MOUNTING PLATE – CONNECTION TO

SIGN CABINET, SPACING AND VERTICAL

CONNECTION BY STRUCTURAL

NOTE:

INCOMING WIRING BY DIVISION 26 ELECTRICAL CONTRACTOR,

SIGN MANUFACTURER TO LOCATE AND PROVIDE DEVICES NOTED.

INCOMING POWER CIRCUIT DISCONNECT,

20 AMP RATED, 120/277V AC

ETC FOUNDRY DMX TO 0-10V CONVERTER

Ground TransportationRestrooms

Baggage ClaimConcourse B C D

CMB2 - ELEVATION

SCALE: 1" = 1' - 0"

2'

0"

1'

0" 1'

0"

3"

13' - 0"

8' - 4"

LE

N

G

TH

O F

V

ER

TI

C

A L

M O

U N

TI

N

G

SU

PP

O

R T

VA

R

IE

S

D

EP

EN

D

IN

G

O N

C

EI

LI

N

G H

EI

G

H T

LIGHT BAR

FABRIC SIGN FACE: WHITE TANSLUCENT

FABRIC SUBSTRATE WITH OPAQUE AND

TRANSLUCENT DIRECT PRINT GRAPHICS

APPLIED WITH UV INKS. ILLUMINATION TO BE

EVEN WITH NO SHADOWS FROM INTERNAL

HARDWARE. BACKGROUND TO BE OPAQUE

AND MATCH PANTONE 2955. COPY AND

GRAPHICS TO BE TRANSLUCENT AND

MATCH PANTONE 7462 AND WHITE. SQUARE

GRAPHIC CONTAINER TO HAVE

4 POINT STROKE TO MATCH PANTONE 2379.

ENTIRE SIGN FACE INTENDED TO BE BACK

ILLUMINATED. FONT: HELVETICA NEUE LT

STD LIGHT CAP HEIGHT 4"

CABINET: (4) 1' - 0" X 13' - 0" X 3 1/2"

SIGNCOMP FRONT LOAD SOFT ALUMINUM

SIGNAGE FRAME PART #3095, PAINTED

PORT WHITE

REMOVABLE END CAP PAINTED PORT WHITE

3" 2" 7" 3"7"7"

2.5" 2.5"

CMB2 - FABRIC FACE PRINTED ALIGNMENT MARKS

SCALE: 1" = 1' - 0"

13' - 2"

3' - 3 1/2" 3' - 3 1/2" 3' - 3 1/2"3' - 3 1/2"

1'

2"

VISIBLE SIGN FACE:

12' - 11" W X 11-1/4" H

PRINTED THIN BORDER LINE TO MATCH

PANTONE 7462. USE FOR PRECISE

ALIGNMENT OF FABRIC WITH SIGN

CABINET DURING INSTALLATION.

13' - 0" W X 1' - 0" H

OVERALL PRINTED FABRIC:

13' - 2" W X 1' - 2" H

COLOR TO MATCH PANTONE 2955

PROVIDE EQUIDISTANT THIN LINES TO

MATCH PANTONE 7462. PRINT 6 TOTAL, 3

ON TOP AND 3 ON BOTTOM EDGE OF

FABRIC FACE. USE FOR PRECISE

ALIGNMENT OF FABRIC WITH SIGN

CABINET DURING INSTALLATION.

Gates D10-D15

Ticketing

Concourse B C E

Concouse B C EGates D10-D15

Ticketing

SCALE: 1" = 1' - 0"

CMB2 - MESSAGE LAYOUTS2

CMB2-013 A

CMB2-013 B

15' - 0" A .F.F.

TO

TO

P O

F SIG

N

CMB2 - MOUNTING CONDITION

SCALE: 1/4" = 1' - 0"

SEE STRUCTURAL

FOR ABOVE CEILING

ATTACHMENT

NOTE:

SEE FABRICATION DETAILS FOR CM2

G9.103