PDX 2026-512 (66) E2.701.pdf

PDF 799 KB Posted

Attached to
Portland International Airport Terminal and Concourses Wayfinding Signage (Re-Bid)
Solicitation number
146219
Issued by
Multnomah County, Oregon

About this file

This is an electrical reflected ceiling plan drawing for the Portland International Airport Terminal and Concourses Wayfinding Signage project in Oregon. The drawing, designated E2.701, depicts the Terminal Enplaning Sector 01 and includes electrical specifications for blade sign installations and DMX control systems. The project involves reconnecting new blade signs to existing circuits and installing DMX cable connections between multiple signs, with daisy-chaining capabilities from a 4-channel ETC Gateway located within the concourse. The drawing was prepared by PAE Engineers and is dated August 2026, with design work completed by G. Parthemer, P. Marks, and D. Peek under the direction of Jay Ostlund. The plan is drawn at a scale of 1/8" = 1'-0" and serves as part of the comprehensive wayfinding signage installation for the airport terminal and concourses.

The technical specifications require concealed conduit routing for all DMX circuits, except where circuits extend to suspended signs, with patching and painting to be provided as necessary. Signs with DMX channel designations must connect to an ETC DMX Controller furnished with each sign, with un-switched line voltage connections required. The typical cable routing details and specifications for cable and conduit requirements are referenced on drawing E5.001. The document is stamped with approval from Licensed Professional Engineer Grant R. Parthemer (License 44775PE, Oregon), with an expiration date of December 31, 2026, and was electronically signed on July 24, 2026.

View the file

Other files

File Type Posted
PDX 2026-512 (17) S2.253.pdf PDF
PDX 2026-512 (181) G2.273.pdf PDF
PDX 2026-512 (08) S0.003.pdf PDF
PDX 2026-512 (85) E9.004.pdf PDF
PDX 2026-512 (174) G2.260.pdf PDF
PDX 2026-512 (128) G2.071.pdf PDF
PDX 2026-512 (39) E0.002.pdf PDF
PDX 2026-512 (95) T2.200.pdf PDF
PDX 2026-512 (67) E2.740.pdf PDF
PDX 2026-512 (159) G2.202.pdf PDF
PDX 2026-512 (222) G9.117.pdf PDF
PDX 2026-512 (139) G2.131.pdf PDF
PDX 2026-512 (96) T2.252.pdf PDF
PDX 2026-512 (28) S2.370.pdf PDF
PDX 2026-512 (163) G2.221.pdf PDF
PDX 2026-512 (148) G2.153.pdf PDF
PDX 2026-512 (18) S2.270.pdf PDF
PDX 2026-512 (103) G0.002.pdf PDF
PDX 2026-512 (43) E1.200.pdf PDF
PDX 2026-512 (93) T2.153.pdf PDF
PDX 2026-512 (115) G2.025.pdf PDF
PDX 2026-512 (145) G2.143.pdf PDF
PDX 2026-512 (229) G9.124.pdf PDF
PDX 2026-512 (122) G2.053.pdf PDF
PDX 2026-512 (197) G2.371.pdf PDF
PDX 2026-512 (65) E2.700.pdf PDF
PDX 2026-512 (241) G9.136.pdf PDF
PDX 2026-512 (164) G2.222.pdf PDF
PDX 2026-512 (179) G2.271.pdf PDF
PDX 2026-512 (149) G2.160.pdf PDF
PDX 2026-512 (196) G2.363.pdf PDF
PDX 2026-512 (215) G9.110.pdf PDF
PDX 2026-512 (165) G2.231.pdf PDF
PDX 2026-512 (202) G2.442.pdf PDF
PDX 2026-512 (146) G2.151.pdf PDF
PDX 2026-512 (177) G2.263.pdf PDF
PDX 2026-512 (240) G9.135.pdf PDF
PDX 2026-512 (140) G2.131.pdf PDF
PDX 2026-512 (31) S2.373.pdf PDF
PDX 2026-512 (73) E2.771.pdf PDF
PDX 2026-512 (75) E2.773.pdf PDF
PDX 2026-512 (238) G9.133.pdf PDF
PDX 2026-512 (05) GI4.000.pdf PDF
PDX 2026-512 (198) G2.372.pdf PDF
PDX 2026-512 (214) G9.109.pdf PDF
Substitution Request Form.pdf PDF
PDX 2026-512 (162) G2.212.pdf PDF
PDX 2026-512 (201) G2.431.pdf PDF
PDX 2026-512 (0) Re-Bid COVER.pdf PDF
PDX 2026-512 (168) G2.241.pdf PDF
Show 40 more

Latest 50 of 248 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DE

DD

DC

DB

DA

D1

D2D3D4D5D6D7

C01

ZZ

2' 2'CE 3'

WW

VV

T17 T16T18T19 T15

TS

TT

TS.7

TS.9

TT.1

FM3

N

2P1D-4A-A:24.

DMX2D-16D-DIN-A:CH1

M A

T C

H L

IN

E

S E

E S

H E

E T

E .7

N

KEY PLAN

SCALE: N.T.S.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲

151 SW 1st Avenue #300 Portland, OR 97204

503.226.2921 pae-engineers.com

7/24/2026 8:51:55 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/26-1037 - PDX Wayfinding MEP25.rvt

TERMINAL - ENPLANING - SECTOR 01 - REFLECTED CEILING PLAN - ELECTRICAL

PORTLAND INTERNATIONAL AIRPORT

E2.701

AUGUST 2026

G. PARTHEMER

P. MARKS

D. PEEK

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

PDX 2026-512

CD

1031012026D004

N

SCALE: 1/8" = 1'-0"

TERMINAL - ENPLANING - SECTOR 01 - REFLECTED CEILING PLAN - ELECTRICAL

KEYNOTE(S) :#

1. RECONNECT NEW BLADE SIGN TO

EXISTING CIRCUIT.

24'16'8'4'0'

SCALE: IN FEET

NOTE(S):

1. AT SIGNS SHOWN WITH DMX CHANNEL

DESIGNATION, CONNECT UN-SWITCHED

LINE VOLTAGE TO ETC DMX

CONTROLLER FURNISHED WITH SIGN

UNLESS OTHERWISE NOTED.

2. AT SIGNS SHOWN WITH DMX CHANNEL

DESIGNATION, CONNECT NEW DMX

CABLE TO ETC DMX CONTROLLER

FURNISHED WITH SIGN.

3. DAISY CHAIN DMX CABLE BETWEEN

SIGNS FROM 4 CHANNEL ETC GATEWAY

IN THIS CONCOURSE. CONNECT TO ETC

UNISON FOUNDRY 0-10V CONTROLLER

PROVIDED WITH SIGN AND EXTEND

0-10V WIRING TO SIGN DRIVERS. SEE

FLOOR PLANS FOR GATEWAY

LOCATION AND SPECIFICATIONS FOR

CABLE AND CONDUIT REQUIREMENTS.

ROUTE ALL DMX CIRCUITS CONCEALED

EXCEPT WHERE EXTENDING OUT TO

SUSPENDED SIGNS.

4. WHERE NEW OR EXTENDED CIRCUITS

ARE REQUIRED, CONCEAL CONDUIT

AND PROVIDE PATCHING AND PAINTING

AS REQUIRED.

5. REFER TO TYPICAL CABLE ROUTING

DETAIL ON E5.001 FOR SUSPENDED

SIGNAGE.

L

R E

N

G

O

R

I

E

I

S

ST

S

E

E

N

ER

F

E

E

G

OD R

N

EXPIRES: 12/31/2026

P

A

I

44775PE

OREGONJ

U L Y 13 , 19 9

9G R

A

NT R. PA RTHEM

E R

07/24/26

2026-07-24T10:10:25-0700
Grant Parthemer
I am approving this document.

File details come from the government source that posted it. Updated .