PDX 2026-512 (38) E0.001.pdf

PDF 507 KB Posted

Attached to
Portland International Airport Terminal and Concourses Wayfinding Signage (Re-Bid)
Solicitation number
146219
Issued by
Multnomah County, Oregon

About this file

This is an electrical symbols, legends, and abbreviations sheet for the Portland International Airport Terminal and Concourses Wayfinding Signage project (PDX 2026-512) prepared by PAE Engineers. The document serves as a reference guide for electrical drawings and specifications related to the wayfinding signage installation at Portland International Airport in Oregon. The sheet establishes standardized electrical equipment naming conventions, power classifications, concourse and area designations, receptacle types, lighting symbols, fire alarm system indicators, and control devices used throughout the project documentation. Key conventions include equipment location identifiers within grid systems, voltage classifications ranging from 208Y/120V to 12470Y/7200V, and designations for normal, emergency, standby, and UPS power systems. The document was prepared by G. Parthemer, P. Marks, and D. Peek under the direction of Jay Ostlund, dated August 2026, with an electronic signature dated July 24, 2026.

The legends and abbreviations cover comprehensive electrical system components including power distribution equipment such as panels, transformers, switchgear, and bus systems; lighting fixtures with various configurations including recessed, surface, pendant, and pole-mounted options; fire alarm and life safety systems including detectors, speakers, bells, and notification devices; and control systems such as occupancy sensors, dimmer switches, and relay cabinets. The document establishes critical distinctions between existing equipment shown in halftone, new equipment shown in full tone, and demolished equipment shown in dashed lines. General notes address requirements for concealed raceways in finished spaces, coordination with architectural plans, firestopping at penetrations, flexible conduit connections at expansion joints, and port standard identification and labeling per Division 26 05 53. Demolition notes specify the complete removal of equipment and associated conduit when all load is removed from circuits and require restoration of damaged surfaces to match existing conditions. The fire alarm system is identified as a contractor design-build system requiring complete code compliance throughout remodeled spaces.

View the file

Other files

File Type Posted
PDX 2026-512 (17) S2.253.pdf PDF
PDX 2026-512 (181) G2.273.pdf PDF
PDX 2026-512 (08) S0.003.pdf PDF
PDX 2026-512 (85) E9.004.pdf PDF
PDX 2026-512 (174) G2.260.pdf PDF
PDX 2026-512 (128) G2.071.pdf PDF
PDX 2026-512 (39) E0.002.pdf PDF
PDX 2026-512 (95) T2.200.pdf PDF
PDX 2026-512 (67) E2.740.pdf PDF
PDX 2026-512 (159) G2.202.pdf PDF
PDX 2026-512 (222) G9.117.pdf PDF
PDX 2026-512 (139) G2.131.pdf PDF
PDX 2026-512 (96) T2.252.pdf PDF
PDX 2026-512 (28) S2.370.pdf PDF
PDX 2026-512 (163) G2.221.pdf PDF
PDX 2026-512 (148) G2.153.pdf PDF
PDX 2026-512 (18) S2.270.pdf PDF
PDX 2026-512 (103) G0.002.pdf PDF
PDX 2026-512 (43) E1.200.pdf PDF
PDX 2026-512 (93) T2.153.pdf PDF
PDX 2026-512 (115) G2.025.pdf PDF
PDX 2026-512 (145) G2.143.pdf PDF
PDX 2026-512 (229) G9.124.pdf PDF
PDX 2026-512 (122) G2.053.pdf PDF
PDX 2026-512 (197) G2.371.pdf PDF
PDX 2026-512 (65) E2.700.pdf PDF
PDX 2026-512 (241) G9.136.pdf PDF
PDX 2026-512 (164) G2.222.pdf PDF
PDX 2026-512 (179) G2.271.pdf PDF
PDX 2026-512 (149) G2.160.pdf PDF
PDX 2026-512 (196) G2.363.pdf PDF
PDX 2026-512 (215) G9.110.pdf PDF
PDX 2026-512 (165) G2.231.pdf PDF
PDX 2026-512 (202) G2.442.pdf PDF
PDX 2026-512 (146) G2.151.pdf PDF
PDX 2026-512 (177) G2.263.pdf PDF
PDX 2026-512 (240) G9.135.pdf PDF
PDX 2026-512 (140) G2.131.pdf PDF
PDX 2026-512 (31) S2.373.pdf PDF
PDX 2026-512 (73) E2.771.pdf PDF
PDX 2026-512 (75) E2.773.pdf PDF
PDX 2026-512 (238) G9.133.pdf PDF
PDX 2026-512 (05) GI4.000.pdf PDF
PDX 2026-512 (198) G2.372.pdf PDF
PDX 2026-512 (214) G9.109.pdf PDF
Substitution Request Form.pdf PDF
PDX 2026-512 (162) G2.212.pdf PDF
PDX 2026-512 (201) G2.431.pdf PDF
PDX 2026-512 (0) Re-Bid COVER.pdf PDF
PDX 2026-512 (168) G2.241.pdf PDF
Show 40 more

Latest 50 of 248 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NL NIGHT LIGHT CIRCUIT

PUBLIC ADDRESS

WEATHER PROOFWP

WIRELESS ACCESS POINTWAP

WATTSW

VAPOR PROOFVP

VOLT AMPERESVA

VOLTAGEV

UNINTERRUPTABLE POWER SUPPLYUPS

UNDERGROUNDUG

TYPICALTYP

TELEVISIONTV

TELEPHONE TERMINAL CABINETTTC

TELEPHONE TERMINAL BOARDTTB

TAMPERPROOFTP

TIME DELAYTD

SWITCHSW

SOLENOID VALVESV

STARTERSTR

SDP

POWERPWR

POLYVINYL CHLORIDE CONDUITPVC

PANELBOARDPNL

POWER FACTORPF

PHOTO ELECTRIC CELLPE

PA

NOT IN CONTRACTNIC

MANUAL TRANSFER SWITCHMTS

MAIN LUGS ONLYMLO

MECHANICALMECH

MAIN DISTRIBUTION PANELMDP

MOTOR CONTROL CENTERMCC

MAIN CIRCUIT BREAKERMCB

MINIMUM CIRCUIT AMPSMCA

MASTER ANTENNA TELEVISIONMATV

LOW VOLTAGELV

LIGHTINGLTG

LIGHTNING ARRESTORLA

KILOVOLT AMPERES REACTIVEKVAR

KILOVOLTKV

KILOWATT HOURKWH

KILOWATTKW

JUNCTION BOXJB

ISOLATED GROUNDIG

HERTZHZ

HIGH VOLTAGEHV

HORSEPOWERHP

GROUNDGND

GALVANIZED RIGID CONDUITGRC

GROUND FAULT CIRCUIT INTERRUPTERGFCI

GROUND FAULT INTERRUPTERGFI

GROUND FAULT PROTECTIONGFP

INSTALLED BY OWNER

FURNISHED BY OWNERFOIO

INSTALLED BY CONTRACTOR

FURNISHED BY OWNERFOIC

INSTALLED BY CONTRACTOR

FURNISHED BY CONTRACTORFCIC

FLUORESCENTFLUOR

FULL LOAD AMPSFLA

FIRE ALARMFA

ELECTRIC WATER COOLEREWC

EMERGENCY POWER OFFEPO

EXPLOSION PROOFEP

ELECTRIC METALLIC TUBINGEMT

ELECTRICAL MAIN GROUND BAREMGB

DOWNDN

COPPERCU

CURRENT TRANSFORMERCT

CEILINGCLG

CIRCUITCKT

CLOSED CIRCUIT TELEVISIONCCTV

CONDUITC

CIRCUIT BREAKERCB

AUTOMATIC TRANSFER SWITCHATS

ARCHITECT / ARCHITECTURALARCH

ALUMINUMAL

AMPERE (AMP)A

ABOVE FINISHED FLOORAFF

AMERICAN WIRE GAUGEAWG

ELECTRICAL LEGEND:

PASSENGER BOARDING BRIDGEPBB

P - POWER PANEL

LDC - LIGHTING DIMMING RELAY CABINET

B - SECOND IN SERIES OF EQUIPMENT

A - FIRST IN SERIES OF EQUIPMENT

IDENTIFIER:

(WITHIN GRID SYSTEM)

1A - NEARERST GRIDLINE INTERSECTION

EQUIPMENT LOCATION WITHIN GRID SYSTEM OR FIELD LOCATED EQUIPMENT:

4 - FOURTH LEVEL

3 - THIRD LEVEL

2 - SECOND LEVEL

1 - FIRST LEVEL OR GRADE LEVEL (ITEMS EXTERNAL TO TERMINAL)

0 - TUNNEL/VAULT/UNDERGROUND

BUILDING LEVEL OR ELEVATION:

L - LIGHTING PANEL

G - GENERATOR

E - SECTIONALIZING ELBOW CABINET

C - STARTER/CONTROLLER

EQUIPMENT:

15 - 12470Y/7200V 5 - 4160Y/2400V 4 - 480Y/277V 2 - 208Y/120V

VOLTAGE:

S - STANDBY POWER LEGALLY REQUIRED (NEC 701)

E - EMERGENCY POWER LEGALLY REQUIRED (NEC 700)

BLANK - NORMAL POWER

POWER CLASSIFICATION:

A1A-TL4E -

PZ - MINI POWER ZONE

ETC.

PDX ELECTRICAL EQUIPMENT NAMING CONVENTION:

O - OPTIONAL STANDBY POWER (NEC 702)

U - UNINTERRUPTIBLE POWER

R - RESISTOR

S - SUB DISTRIBUTION PANEL

T - TRANSFORMER

A - AUTOMATIC TRANSFER SWITCH

B - BUSWAY

D - MAIN/SWITCHGEAR DISTRIBUTION PANEL

U - UPS

V - VARIABLE FREQUENCY DRIVE

W - EXTERNAL UPS WRAP-AROUND BYPASS SWITCH

5 - FIFTH LEVEL

6 - SIXTH LEVEL

7 - SEVENTH LEVEL

CONCOURSE OR AREA:

AF - AIRFIELD (RUNWAY OR TAXIWAY)

AOA - AIRCRAFT OPERATING AREA

B - CONCOURSE B

C - CONCOURSE C

D - CONCOURSE D

DPS - DEICING PUMP STATION

E - CONCOURSE E

EL - HQ EMPLOYEE PARKING LOT

EXP - ECONOMY LOT EXIT PLAZA BUILDING

GS - GROUND SOURCE WELL SITES

H - HEADQUARTERS (HQ)

HL - TRANSPORTATION PROVIDERS HOLD LOT

M - MAINTENANCE FACILITY

P - PARKING STRUCTURE #1 (SHORT TERM)

P2 - PARKING STRUCTURE #2 (LONG TERM)

P3 - PARKING STRUCTURE #3 (LONG TERM)

PL - PARKING LOT

Q - QTA

R - AIRCRAFT RESCUE & FIREFIGHTING FACILITY (ARFF)

RC - RENTAL CAR CENTER

S - STREET (ITEMS LOCATED ADJACENT TO ROADWAY SYSTEM)

T - TERMINAL (TICKETING AND BAGGAGE)

TP - DEICING TREATMENT PLANT

U - CUP

V - VEHICLE GATE

X - EXIT PLAZA (PARKING EXIT BUILDING)

ELECTRICAL VEHICLE CHARGING STATION NUMBERING

EV<X> - (AREA)<Y>

<X> = SEQUENTIAL NUMBER

<Y> = LEVEL

(AREA) = CONCOURSE OR AREA

MISCELLANEOUS EQUIPMENT:

POTABLE WATER CABINETPWC

TRANSFER SWITCHXFSW

TRANSFORMERXFMR

J

WALL RECEPTACLE: DUPLEX, QUADPLEX

PUSH BUTTON STATION: SINGLE, DOUBLE

JUNCTION BOX

CEILING RECEPTACLE: DUPLEX, QUADPLEX

POWER POLE, POWER, COMBINATION

CIRCUITS AS INDICATED.

CONNECTION TO EQUIPMENT PROVIDED BY OTHERS

FB1

1,3,51,3,5

J

JUNCTION BOX HOME RUN. CIRCUITS AS INDICATED.

JUNCTION BOX HOME RUN & FURNITURE FEED.

CIRCUITS AS INDICATED.

H

F

1,3,5

1,3,5

X

X

X LETTER DESIGNATOR:

42. DENOTES CIRCUIT NUMBER.

REFER TO SHEET GENERAL NOTES FOR PANELBOARD.

T

ELECTRICAL EQUIPMENT

TRANSFORMER

ENCLOSURE: SURFACE, RECESSED

PANELBOARD: SURFACE, RECESSED

GROUND PAD

GROUND CONNECTION, GROUND ROD IN TEST WELL

DENOTES GFCI

SPECIAL PURPOSE RECEPTACLE.

FB2

PT1 PT2

DENOTES SPLIT-WIRED, HALF SWITCHED / CONTROLLED

REFER TO SPECIFICATIONS & PLANS FOR CONTROL

INFORMATION.

X

E = EMERGENCY

U = UPS

S = STANDBY

C = CRITICAL

H = SPLIT RECEPTACLE

T = TAMPERPROOF RECEPTACLE

DENOTES RECEPTACLE ABOVE COUNTER

OR HEIGHT AS NOTED

DENOTES GFCI AND

WEATHER PROOF

G SINGLE WALL RECEPTACLE, FACELESS GFCI

REMOTE TEST BUTTON

G G

WW

FLUSH FLOORBOX RECEPTACLE. REFER TO SCHEDULE

FOR QUANTITY AND TYPES OF DEVICES.

FLUSH POKE-THROUGH RECEPTACLE. REFER TO

SCHEDULE FOR QUANTITY AND TYPES OF DEVICES.

DENOTES FULL SWITCHED / CONTROLLED. REFER TO

SPECIFICATIONS & PLANS FOR CONTROL

INFORMATION.

IG = ISOLATED GROUND

P = SURGE PROTECTIVE DEVICE

A = AFCI

B = WITH USB OUTLETS

2NP1:42. DENOTES PANELBOARD AND CIRCUIT NUMBER.

FB3 FB4

PT3

SWITCHED / CONTROLLED FLUSH FLOORBOX

RECEPTACLE. REFER TO SCHEDULE & PLANS FOR

CONTROL INFORMATION.

PT4

SWITCHED / CONTROLLED FLUSH POKE-THROUGH

RECEPTACLE. REFER TO SCHEDULE & PLANS FOR

CONTROL INFORMATION.

FB1

PT1

X

X

POWER - PLANS:

SUB DISTRIBUTION PANEL

SERVICE ENTRANCESE

ELECTRICAL GROUND BAREGB

EMERGENCYEMERG

TECHNOLOGY GROUND BARTGB

TECHNOLOGY MAIN GROUND BARTMGB

ASSEMBLYASSY

RESTROOM SENSOR PANELRSP

EXIT LANE SECURITY ENCLOSUREELSE

EMERGENCYEM

TEMPORARY GENERATOR DOCKNG STATIONTGDS

UNINTERRUPTABLE POWER SUPPLY

TIE CABINET

UPSTC

TRANSPORTATION SECURITY ADMINISTRATION TSA

CONCESSIONSCONC

RECEPTACLERCPT

M - MOTOR CONTROL CENTER

HEATING, VENTILATING, AND AIR

CONDITIONING

HVAC

NEUTRAL GROUNDING RESISTORNGR

PM NETWORKED POWER METERING/MONITORING

ARC FAULT CIRCUIT INTERRUPTERAFCI

ELECTRICALELECT

TECHNOLOGYTECH

UNIVERSAL SERIAL BUSUSB

J

TC - TIE CABINET

ETHERNET SWITCHES

GROUND BARGB

UNLESS NOTED OTHERWISEUNO

N.T.S. NOT TO SCALE

DIVISIONDIV

DISTRIBUTED ANTENNA SYSTEMDAS

PRE-CONDITIONED AIRPCA

BAGGAGE POWER ENCLOSUREBPE

CHECKED BAGGAGE RESOLUTION AREACBRA MOBILE INSPECTION TABLEMIT

PROGRAMMABLE LOGIC CONTROLLERPLC

ENCLOSED CIRCUIT BREAKER

ELEVATORELV

KILOVOLT AMPEREKVA

GROUND SOURCE HEAT PUMP SYSTEMGSHPS

LRC - LIGHTING RELAY CABINET

BUSPLUGB

FF F F

SS S S

CC

FF F F

C C

CD

SS

HI P

F

F

F

FS TS

F FIRE ALARM: VISUAL

FIRE ALARM: HORN; HORN W/VISUAL

MAGNETIC DOOR HOLDER, CLOSER

DUCT DETECTOR, TYPE AS NOTED

DETECTOR: IONIZATION, HEAT, PHOTOELECTRIC

SPRINKLER SYSTEM SWITCH: FLOW, TAMPER

MANUAL FIRE ALARM STATION, OUTPUT MODULE

FIREMANS PHONE JACK

DETECTOR: BEAM TRANSMITTER, BEAM RECIEVER

WALL CEILING

FIRE ALARM: SPEAKER; SPEAKER W/VISUAL

NOTIFICATION DEVICES

FIRE ALARM: CHIME; CHIME W/VISUAL

FIRE ALARM: BELL; BELL W/VISUAL

FIRE ALARM:

T

CIRCUIT BREAKER, ENCLOSED, WITH GROUND

FAULT PROTECTION, DRAW OUTGFP

DISTRIBUTION BOARD, WITH INTERNAL BUS

PANEL

NAME PANELBOARD,

TRANSFORMER

T T SERVICE TRANSFORMER, WITH VAULT

ELECTRICAL BUSDUCT RISER , BUS PLUG-IN

CIRCUIT BREAKER, BUS PLUG-IN FUSED SWITCH

XX

SH#

XXXX FEEDER CONTINUATION CALLOUT, FEEDER TAG

G GENERATOR, AUTOMATIC TRANSFER SWITCH

M M UTLITY METER, METER

SPD

SWITCH, FUSED SWITCH, SWITCH WITH OPERATOR

SURGE PROTECTION DEVICE, PUSH BUTTON

F DISCONNECT, FUSED DISCONNECT,

ENCLOSED CIRCUIT BREAKER

MOTOR, MOTER WITH CONTROLLER, MOTOR

WITH STARTER

PV ARRAY, INVERTER

FEEDER: DROP, RISE, CAP, BREAK, CONTINUATION

POWER - SINGLE LINE DIAGRAM & RISER:

M

PM

ES

NETWORKED POWER METERING/MONITORING

ETHERNET SWITCH

M UTILITY METER, OR TENANT PROVIDED METER

VM CT VOLTAGE SENSOR, CURRENT SENSOR

PM

OS

PEPE

OS

LV P

MK

3 4

L#, F# ; YY

WALL SWITCH: KEY LOCK, MOMENTARY

WALL SWITCH: 3 WAY, 4 WAY

DESIGNATES LUMINAIRE TYPE

(SEE LUMINAIRE SCHEDULE)

YY DENOTES UNIQUE FIXTURE ID

(WHERE DMX CONTROLLED)

ADJUSTABLE ACCENT: MULTILAMP

DOWNLIGHT: SURFACE: SQUARE, ROUND

WALL WASHER: RECESSED: SQUARE, ROUND

PHOTOELECTRIC CELL: WALL

MOUNTED, CEILING MOUNTED

WALL SWITCH: TIMER, MANUAL DIMMER

WALL SWITCH: LOW VOLTAGE, PILOT

WALL SWITCH: 1 POLE, 2 POLE

ADJUSTABLE ACCENT: RECESSED: SQUARE, ROUND

TRACK LIGHTING WITH , WITHOUT CURRENT LIMITER

DT

X

X

DOWNLIGHT: RECESSED: SQUARE, ROUND

EM DESIGNATES EMERGENCY FIXTURE

OCCUPANCY SENSOR: CEILING OR WALL MOUNTED

"X" DESIGNATES DEVICE TYPE:

U: ULTRASONIC

R: INFRARED

DT: DUAL TECHNOLOGY

WALL SWITCH: COMBINATION OCCUPANCY

SENSOR / SWITCH

OS

S S

S S

S S

S S

S

S

S

EMERGENCY NORMAL

WALL WASHER: RECESSED SQUARE, ROUND

ADJUSTABLE ACCENT: SURFACE: SQUARE, ROUND

PENDANT: SQUARE, ROUND

LINEAR: SUSPENDED ASYMMETRIC

LINEAR: SURFACE ASYMMETRIC

LINEAR: SUSPENDED

LINEAR: RECESSED

LINEAR: RECESSED ASYMMETRIC

LINEAR: SURFACE

LINEAR: WALL MOUNTED

LINEAR: WALL MOUNTED ASYMMETRIC

LINEAR: UNDERCABINET

WALL MOUNTED: RECESSED: SQUARE, ROUND

WALL MOUNTED: SURFACE: SQUARE, ROUND

LINEAR ACCENT: ARCHITECTURE INTEGRATED

POLE-MOUNTED: AREA: SQUARE, ROUND

POLE-MOUNTED: STREET: RECTANGULAR, OVAL

POLE-MOUNTED: PEDESTRIAN: SQUARE, ROUND

BOLLARD 360: SQUARE, ROUND

INGRADE SQUARE, ROUND

INGRADE ADJUSTABLE SQUARE, ROUND

FLOOD LIGHT

EXIT SIGN: TOP SURFACE OR TOP RECESSED:

SINGLE , DOUBLE

EXIT SIGN: SIDE OR FLAG MOUNT: SINGLE , DOUBLE

EXIT SIGN: BACK SURFACE MOUNT

BOLLARD 180: SQUARE, ROUND

NA

NA

NA

NA

NA

NA

NA

NA

STRIP LIGHT

LIGHTING LEGEND:

VSD

S

WALL SWITCH COMBINATION OCCUPANCY

SENSOR / DIMMING SWITCH, VACANCY

SENSOR/DIMMING SWITCH

OSD

S

Z# DESIGNATES NORMAL LUMINAIRE ZONE,

DESIGNATES EMERGENCY LUMINAIRE ZONE

(SEE LIGHTING CONTROL SCHEDULE)

Z#E

RC LIGHTING CONTROL RELAY SUGGESTED LOCATION

CS# CONTROL STATION SUGGESTED LOCATION

VS

X

VS

X

DR LIGHTING DRIVER SUGGESTED LOCATION

POWER PACK SUGGESTED LOCATIONPP

NEW, CONNECT TO

STRUCTURAL ENABLING SCOPE IDENTIFIER

NOTE

REPLACE, RELOCATED EXISTING

EXISTING TO REMAIN, EXISTING TO BE REMOVED

NOTE:

THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY

APPEAR ON THIS SHEET THAT DO NOT APPEAR ON THE DRAWINGS.

DESIGNATION SYMBOLS:

123.4

E X

RE

C

R

N

1 ####

HARDWIRED CONNECTION, SEE SCHEDULE.

### MECHANICAL/PLUMBING CONNECTION,

SEE SCHEDULE.

ITP

XX

INTEGRATED TECH POLE

FUTUREF

BT BR

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲

151 SW 1st Avenue #300 Portland, OR 97204

503.226.2921 pae-engineers.com

7/24/2026 8:43:36 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/26-1037 - PDX Wayfinding MEP25.rvt

SYMBOLS, LEGENDS, & ABBREVIATIONS - ELECTRICAL

PORTLAND INTERNATIONAL AIRPORT

E0.001

AUGUST 2026

G. PARTHEMER

P. MARKS

D. PEEK

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

PDX 2026-512

CD

1031012026D004

1. ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN AS

HALFTONE ARE EXISTING TO REMAIN, UNLESS NOTED.

2. ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN AS

FULL-TONE ARE NEW, UNLESS OTHERWISE NOTED

3. INTERIOR RACEWAY SHALL BE CONCEALED WHEN LOCATED

WITHIN FINISHED SPACES UNLESS NOTED.

4. RACEWAY SHALL BE IN CEILING UNLESS NOTED.

5. REFER TO ARCHITECTURAL CEILING PLANS, ELEVATIONS, AND

FLOOR PLANS FOR LOCATIONS OF CEILING, WALL, AND FLOOR

MOUNTED DEVICES AND EQUIPMENT. WHERE INTERIOR

ELEVATIONS DIFFER BETWEEN ARCHITECTURAL AND

ENGINEERING DRAWINGS, NOTIFY THE PORT.

6. THE FIRE ALARM SYSTEM IS A CONTRACTOR DESIGN-BUILD

SYSTEM. SELECT DEVICES ARE SHOWN FOR COORDINATION.

PROVIDE REQUIRED DEVICES TO COMPLY WITH CODE

THROUGHOUT REMODELED SPACES. CONTRACTOR SHALL

PROVIDE FIRE ALARM/VOICE EVACUATION DEVICES,

ACCESSORIES AND ALL ADDITIONAL ITEMS REQUIRED FOR A

COMPLETE AND OPERATIONAL CODE COMPLIANT SYSTEM.

CONDUIT ROUTING, SIZING, AND QUANTITIES. REFERENCE

SPECIFICATION DIVISION 28 46 00 FOR ADDITIONAL

INFORMATION.

7. PROVIDE FLEXIBLE CONDUIT CONNECTIONS NEAR EXPANSION

JOINTS FOR CONDUITS THAT CROSS SEISMIC EXPANSION

JOINTS REFER TO STRUCTURAL DRAWINGS FOR SEISMIC

JOINT LOCATIONS.

8. DIVISION 26 TO PROVIDE FIRESTOPPING AT PENETRATIONS

THROUGH RATED STAIR ENCLOSURES, RATED EGRESS

CORRIDORS, RATED SHAFTS, FLOOR AND CEILING ASSEMBLIES

IN ACCORDANCE WITH DIVISION 07.

9. REFER TO SPECIFICATION 26 05 53 FOR PORT STANDARD

IDENTIFICATION AND LABELING REQUIREMENTS OF

ELECTRICAL EQUIPMENT.

NOTE(S):

ELECTRICAL PLAN SHEETS

1. ELECTRICAL EQUIPMENT, DEVICES AND FEEDER SHOWN AS

HALFTONE ARE EXISTING TO REMAIN, UNLESS OTHERWISE

NOTED.

2. WHERE ALL LOAD IS REMOVED FROM A CIRCUIT, THE CONDUIT,

CONDUCTOR AND HANGERS SHALL BE REMOVED IN ENTIRETY

BACK TO THE SOURCE PANEL. WHERE CONDUIT IS

CONCEALED, REMOVE CONDUCTORS AND ABANDON CONDUIT.

3. REMOVE BRANCH CIRCUITING ASSOCIATED WITH ITEMS

IDENTIFIED FOR DEMOLITION. PROVIDE CONDUIT AND

CONDUCTORS TO MAINTAIN CONNECTION TO ALL ITEMS THAT

REMAIN WHERE SERVICE IS INTERRUPTED WITH DEMOLITION.

4. ALL DEMOLITION ITEMS SHOWN ARE BASED UPON RECORD

DRAWINGS AND SITE OBSERVATIONS, NOT ALL DEVICES MAY

BE SHOWN.

5. REMOVE ALL BRANCH CIRCUITING AND HANGERS ASSOCIATED

WITH ITEMS SHOWN FOR DEMOLITION.

6. AFTER REMOVAL OF ELECTRICAL SYSTEMS, RESTORE

DAMAGED SURFACES AND FINISHES TO MATCH EXISTING.

7. THE FIRE ALARM SYSTEM IS CONTRACTOR DESIGN-BUILD.

CONTRACTOR TO IDENTIFY ALL FIRE ALARM SYSTEM

COMPONENTS AND SYSTEMS FOR DEMOLITION, AND PROVIDE

DEMOLITION SHOP DRAWINGS. PROVIDE AND INDICATE

SYSTEM RE-ROUTES AND TEMPORARY SYSTEM INTERIM

CONDITIONS UNTIL PDX 2021-510 COMPLETED SYSTEM SHOP

DRAWINGS ARE AVAILABLE AND SYSTEM BUILD OUT CAN BE

COMPLETED.

NOTE(S):

DEMOLITION PLAN SHEETS

1. REFER TO ONE-LINE DIAGRAM OR PANEL SCHEDULES FOR

OVERCURRENT PROTECTION CHARACTERISTICS AND CIRCUIT

NUMBERS.

2. COORDINATE EQUIPMENT CONNECTION REQUIREMENTS WITH

INSTALLING CONTRACTOR PRIOR TO PERFORMING ANY

ELECTRICAL WORK.

3. COMBINATION STARTER/DISCONNECTS AND DISCONNECT

SWITCHES SHALL BE LOCATED WITHIN SIGHT OF AND

ADJACENT TO EQUIPMENT SERVED. COORDINATE

DISCONNECT INSTALLATION AND LOCATION WITH EQUIPMENT

INSTALLER.

4. EQUIPMENT LOCATIONS ARE SHOWN ON ELECTRICAL

DRAWINGS FOR REFERENCE, BUT MAY NOT INCLUDE EVERY

ITEM LISTED IN SCHEDULE. LOCATIONS SHOWN ON OTHER

DISCIPLINE DRAWINGS TAKE PRECEDENCE.

NOTE(S):

EQUIPMENT CONNECTION SCHEDULE SHEETS

1. ALL ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN

AS HALFTONE ARE EXISTING TO REMAIN, UNLESS OTHERWISE

NOTED.

2. ALL ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN

AS SOLID DASH ARE DEMOLITION, UNLESS OTHERWISE NOTED.

3. DEMOLISHED ITEMS SHOWN AND ASSOCIATED FEEDERS,

CONDUIT, CONDUCTORS AND HANGERS SHALL BE REMOVED IN

THEIR ENTIRETY.

4. REFER TO SPECIFICATION FOR EQUIPMENT TO BE SALVAGED

AND RETURNED TO PORT.

5. ALL ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN

AS SOLID ARE NEW, UNLESS OTHERWISE NOTED.

NOTE(S):

ONE LINE SHEETS

1. ALL BRANCH CIRCUITS SHOWN IS EXISTING TO REMAIN,

UNLESS OTHERWISE NOTED.

2. ALL DEMOLISHED BRANCH CIRCUITS SHALL HAVE BREAKER

TURNED OFF AND MARKED AS SPARE WITHIN PANEL

DIRECTORY.

NOTE(S):

PANEL SCHEDULE SHEETS

L

R E

N

G

O

R

I

E

I

S

ST

S

E

E

N

ER

F

E

E

G

OD R

N

EXPIRES: 12/31/2026

P

A

I

44775PE

OREGONJ

U L Y 13 , 19 9

9G R

A

NT R. PA RTHEM

E R grant.parthemer Text Box 7/24/26

2026-07-24T10:06:45-0700
Grant Parthemer