PDX 2026-512 (38) E0.001.pdf
PDF 507 KB Posted
- Solicitation number
- 146219
- Issued by
- Multnomah County, Oregon
About this file
This is an electrical symbols, legends, and abbreviations sheet for the Portland International Airport Terminal and Concourses Wayfinding Signage project (PDX 2026-512) prepared by PAE Engineers. The document serves as a reference guide for electrical drawings and specifications related to the wayfinding signage installation at Portland International Airport in Oregon. The sheet establishes standardized electrical equipment naming conventions, power classifications, concourse and area designations, receptacle types, lighting symbols, fire alarm system indicators, and control devices used throughout the project documentation. Key conventions include equipment location identifiers within grid systems, voltage classifications ranging from 208Y/120V to 12470Y/7200V, and designations for normal, emergency, standby, and UPS power systems. The document was prepared by G. Parthemer, P. Marks, and D. Peek under the direction of Jay Ostlund, dated August 2026, with an electronic signature dated July 24, 2026.
The legends and abbreviations cover comprehensive electrical system components including power distribution equipment such as panels, transformers, switchgear, and bus systems; lighting fixtures with various configurations including recessed, surface, pendant, and pole-mounted options; fire alarm and life safety systems including detectors, speakers, bells, and notification devices; and control systems such as occupancy sensors, dimmer switches, and relay cabinets. The document establishes critical distinctions between existing equipment shown in halftone, new equipment shown in full tone, and demolished equipment shown in dashed lines. General notes address requirements for concealed raceways in finished spaces, coordination with architectural plans, firestopping at penetrations, flexible conduit connections at expansion joints, and port standard identification and labeling per Division 26 05 53. Demolition notes specify the complete removal of equipment and associated conduit when all load is removed from circuits and require restoration of damaged surfaces to match existing conditions. The fire alarm system is identified as a contractor design-build system requiring complete code compliance throughout remodeled spaces.
View the file
Other files
Show 40 more
Latest 50 of 248 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NL NIGHT LIGHT CIRCUIT
PUBLIC ADDRESS
WEATHER PROOFWP
WIRELESS ACCESS POINTWAP
WATTSW
VAPOR PROOFVP
VOLT AMPERESVA
VOLTAGEV
UNINTERRUPTABLE POWER SUPPLYUPS
UNDERGROUNDUG
TYPICALTYP
TELEVISIONTV
TELEPHONE TERMINAL CABINETTTC
TELEPHONE TERMINAL BOARDTTB
TAMPERPROOFTP
TIME DELAYTD
SWITCHSW
SOLENOID VALVESV
STARTERSTR
SDP
POWERPWR
POLYVINYL CHLORIDE CONDUITPVC
PANELBOARDPNL
POWER FACTORPF
PHOTO ELECTRIC CELLPE
PA
NOT IN CONTRACTNIC
MANUAL TRANSFER SWITCHMTS
MAIN LUGS ONLYMLO
MECHANICALMECH
MAIN DISTRIBUTION PANELMDP
MOTOR CONTROL CENTERMCC
MAIN CIRCUIT BREAKERMCB
MINIMUM CIRCUIT AMPSMCA
MASTER ANTENNA TELEVISIONMATV
LOW VOLTAGELV
LIGHTINGLTG
LIGHTNING ARRESTORLA
KILOVOLT AMPERES REACTIVEKVAR
KILOVOLTKV
KILOWATT HOURKWH
KILOWATTKW
JUNCTION BOXJB
ISOLATED GROUNDIG
HERTZHZ
HIGH VOLTAGEHV
HORSEPOWERHP
GROUNDGND
GALVANIZED RIGID CONDUITGRC
GROUND FAULT CIRCUIT INTERRUPTERGFCI
GROUND FAULT INTERRUPTERGFI
GROUND FAULT PROTECTIONGFP
INSTALLED BY OWNER
FURNISHED BY OWNERFOIO
INSTALLED BY CONTRACTOR
FURNISHED BY OWNERFOIC
INSTALLED BY CONTRACTOR
FURNISHED BY CONTRACTORFCIC
FLUORESCENTFLUOR
FULL LOAD AMPSFLA
FIRE ALARMFA
ELECTRIC WATER COOLEREWC
EMERGENCY POWER OFFEPO
EXPLOSION PROOFEP
ELECTRIC METALLIC TUBINGEMT
ELECTRICAL MAIN GROUND BAREMGB
DOWNDN
COPPERCU
CURRENT TRANSFORMERCT
CEILINGCLG
CIRCUITCKT
CLOSED CIRCUIT TELEVISIONCCTV
CONDUITC
CIRCUIT BREAKERCB
AUTOMATIC TRANSFER SWITCHATS
ARCHITECT / ARCHITECTURALARCH
ALUMINUMAL
AMPERE (AMP)A
ABOVE FINISHED FLOORAFF
AMERICAN WIRE GAUGEAWG
ELECTRICAL LEGEND:
PASSENGER BOARDING BRIDGEPBB
P - POWER PANEL
LDC - LIGHTING DIMMING RELAY CABINET
B - SECOND IN SERIES OF EQUIPMENT
A - FIRST IN SERIES OF EQUIPMENT
IDENTIFIER:
(WITHIN GRID SYSTEM)
1A - NEARERST GRIDLINE INTERSECTION
EQUIPMENT LOCATION WITHIN GRID SYSTEM OR FIELD LOCATED EQUIPMENT:
4 - FOURTH LEVEL
3 - THIRD LEVEL
2 - SECOND LEVEL
1 - FIRST LEVEL OR GRADE LEVEL (ITEMS EXTERNAL TO TERMINAL)
0 - TUNNEL/VAULT/UNDERGROUND
BUILDING LEVEL OR ELEVATION:
L - LIGHTING PANEL
G - GENERATOR
E - SECTIONALIZING ELBOW CABINET
C - STARTER/CONTROLLER
EQUIPMENT:
15 - 12470Y/7200V 5 - 4160Y/2400V 4 - 480Y/277V 2 - 208Y/120V
VOLTAGE:
S - STANDBY POWER LEGALLY REQUIRED (NEC 701)
E - EMERGENCY POWER LEGALLY REQUIRED (NEC 700)
BLANK - NORMAL POWER
POWER CLASSIFICATION:
A1A-TL4E -
PZ - MINI POWER ZONE
ETC.
PDX ELECTRICAL EQUIPMENT NAMING CONVENTION:
O - OPTIONAL STANDBY POWER (NEC 702)
U - UNINTERRUPTIBLE POWER
R - RESISTOR
S - SUB DISTRIBUTION PANEL
T - TRANSFORMER
A - AUTOMATIC TRANSFER SWITCH
B - BUSWAY
D - MAIN/SWITCHGEAR DISTRIBUTION PANEL
U - UPS
V - VARIABLE FREQUENCY DRIVE
W - EXTERNAL UPS WRAP-AROUND BYPASS SWITCH
5 - FIFTH LEVEL
6 - SIXTH LEVEL
7 - SEVENTH LEVEL
CONCOURSE OR AREA:
AF - AIRFIELD (RUNWAY OR TAXIWAY)
AOA - AIRCRAFT OPERATING AREA
B - CONCOURSE B
C - CONCOURSE C
D - CONCOURSE D
DPS - DEICING PUMP STATION
E - CONCOURSE E
EL - HQ EMPLOYEE PARKING LOT
EXP - ECONOMY LOT EXIT PLAZA BUILDING
GS - GROUND SOURCE WELL SITES
H - HEADQUARTERS (HQ)
HL - TRANSPORTATION PROVIDERS HOLD LOT
M - MAINTENANCE FACILITY
P - PARKING STRUCTURE #1 (SHORT TERM)
P2 - PARKING STRUCTURE #2 (LONG TERM)
P3 - PARKING STRUCTURE #3 (LONG TERM)
PL - PARKING LOT
Q - QTA
R - AIRCRAFT RESCUE & FIREFIGHTING FACILITY (ARFF)
RC - RENTAL CAR CENTER
S - STREET (ITEMS LOCATED ADJACENT TO ROADWAY SYSTEM)
T - TERMINAL (TICKETING AND BAGGAGE)
TP - DEICING TREATMENT PLANT
U - CUP
V - VEHICLE GATE
X - EXIT PLAZA (PARKING EXIT BUILDING)
ELECTRICAL VEHICLE CHARGING STATION NUMBERING
EV<X> - (AREA)<Y>
<X> = SEQUENTIAL NUMBER
<Y> = LEVEL
(AREA) = CONCOURSE OR AREA
MISCELLANEOUS EQUIPMENT:
POTABLE WATER CABINETPWC
TRANSFER SWITCHXFSW
TRANSFORMERXFMR
J
WALL RECEPTACLE: DUPLEX, QUADPLEX
PUSH BUTTON STATION: SINGLE, DOUBLE
JUNCTION BOX
CEILING RECEPTACLE: DUPLEX, QUADPLEX
POWER POLE, POWER, COMBINATION
CIRCUITS AS INDICATED.
CONNECTION TO EQUIPMENT PROVIDED BY OTHERS
FB1
1,3,51,3,5
J
JUNCTION BOX HOME RUN. CIRCUITS AS INDICATED.
JUNCTION BOX HOME RUN & FURNITURE FEED.
CIRCUITS AS INDICATED.
H
F
1,3,5
1,3,5
X
X
X LETTER DESIGNATOR:
42. DENOTES CIRCUIT NUMBER.
REFER TO SHEET GENERAL NOTES FOR PANELBOARD.
T
ELECTRICAL EQUIPMENT
TRANSFORMER
ENCLOSURE: SURFACE, RECESSED
PANELBOARD: SURFACE, RECESSED
GROUND PAD
GROUND CONNECTION, GROUND ROD IN TEST WELL
DENOTES GFCI
SPECIAL PURPOSE RECEPTACLE.
FB2
PT1 PT2
DENOTES SPLIT-WIRED, HALF SWITCHED / CONTROLLED
REFER TO SPECIFICATIONS & PLANS FOR CONTROL
INFORMATION.
X
E = EMERGENCY
U = UPS
S = STANDBY
C = CRITICAL
H = SPLIT RECEPTACLE
T = TAMPERPROOF RECEPTACLE
DENOTES RECEPTACLE ABOVE COUNTER
OR HEIGHT AS NOTED
DENOTES GFCI AND
WEATHER PROOF
G SINGLE WALL RECEPTACLE, FACELESS GFCI
REMOTE TEST BUTTON
G G
WW
FLUSH FLOORBOX RECEPTACLE. REFER TO SCHEDULE
FOR QUANTITY AND TYPES OF DEVICES.
FLUSH POKE-THROUGH RECEPTACLE. REFER TO
SCHEDULE FOR QUANTITY AND TYPES OF DEVICES.
DENOTES FULL SWITCHED / CONTROLLED. REFER TO
SPECIFICATIONS & PLANS FOR CONTROL
INFORMATION.
IG = ISOLATED GROUND
P = SURGE PROTECTIVE DEVICE
A = AFCI
B = WITH USB OUTLETS
2NP1:42. DENOTES PANELBOARD AND CIRCUIT NUMBER.
FB3 FB4
PT3
SWITCHED / CONTROLLED FLUSH FLOORBOX
RECEPTACLE. REFER TO SCHEDULE & PLANS FOR
CONTROL INFORMATION.
PT4
SWITCHED / CONTROLLED FLUSH POKE-THROUGH
RECEPTACLE. REFER TO SCHEDULE & PLANS FOR
CONTROL INFORMATION.
FB1
PT1
X
X
POWER - PLANS:
SUB DISTRIBUTION PANEL
SERVICE ENTRANCESE
ELECTRICAL GROUND BAREGB
EMERGENCYEMERG
TECHNOLOGY GROUND BARTGB
TECHNOLOGY MAIN GROUND BARTMGB
ASSEMBLYASSY
RESTROOM SENSOR PANELRSP
EXIT LANE SECURITY ENCLOSUREELSE
EMERGENCYEM
TEMPORARY GENERATOR DOCKNG STATIONTGDS
UNINTERRUPTABLE POWER SUPPLY
TIE CABINET
UPSTC
TRANSPORTATION SECURITY ADMINISTRATION TSA
CONCESSIONSCONC
RECEPTACLERCPT
M - MOTOR CONTROL CENTER
HEATING, VENTILATING, AND AIR
CONDITIONING
HVAC
NEUTRAL GROUNDING RESISTORNGR
PM NETWORKED POWER METERING/MONITORING
ARC FAULT CIRCUIT INTERRUPTERAFCI
ELECTRICALELECT
TECHNOLOGYTECH
UNIVERSAL SERIAL BUSUSB
J
TC - TIE CABINET
ETHERNET SWITCHES
GROUND BARGB
UNLESS NOTED OTHERWISEUNO
N.T.S. NOT TO SCALE
DIVISIONDIV
DISTRIBUTED ANTENNA SYSTEMDAS
PRE-CONDITIONED AIRPCA
BAGGAGE POWER ENCLOSUREBPE
CHECKED BAGGAGE RESOLUTION AREACBRA MOBILE INSPECTION TABLEMIT
PROGRAMMABLE LOGIC CONTROLLERPLC
ENCLOSED CIRCUIT BREAKER
ELEVATORELV
KILOVOLT AMPEREKVA
GROUND SOURCE HEAT PUMP SYSTEMGSHPS
LRC - LIGHTING RELAY CABINET
BUSPLUGB
FF F F
SS S S
CC
FF F F
C C
CD
SS
HI P
F
F
F
FS TS
F FIRE ALARM: VISUAL
FIRE ALARM: HORN; HORN W/VISUAL
MAGNETIC DOOR HOLDER, CLOSER
DUCT DETECTOR, TYPE AS NOTED
DETECTOR: IONIZATION, HEAT, PHOTOELECTRIC
SPRINKLER SYSTEM SWITCH: FLOW, TAMPER
MANUAL FIRE ALARM STATION, OUTPUT MODULE
FIREMANS PHONE JACK
DETECTOR: BEAM TRANSMITTER, BEAM RECIEVER
WALL CEILING
FIRE ALARM: SPEAKER; SPEAKER W/VISUAL
NOTIFICATION DEVICES
FIRE ALARM: CHIME; CHIME W/VISUAL
FIRE ALARM: BELL; BELL W/VISUAL
FIRE ALARM:
T
CIRCUIT BREAKER, ENCLOSED, WITH GROUND
FAULT PROTECTION, DRAW OUTGFP
DISTRIBUTION BOARD, WITH INTERNAL BUS
PANEL
NAME PANELBOARD,
TRANSFORMER
T T SERVICE TRANSFORMER, WITH VAULT
ELECTRICAL BUSDUCT RISER , BUS PLUG-IN
CIRCUIT BREAKER, BUS PLUG-IN FUSED SWITCH
XX
SH#
XXXX FEEDER CONTINUATION CALLOUT, FEEDER TAG
G GENERATOR, AUTOMATIC TRANSFER SWITCH
M M UTLITY METER, METER
SPD
SWITCH, FUSED SWITCH, SWITCH WITH OPERATOR
SURGE PROTECTION DEVICE, PUSH BUTTON
F DISCONNECT, FUSED DISCONNECT,
ENCLOSED CIRCUIT BREAKER
MOTOR, MOTER WITH CONTROLLER, MOTOR
WITH STARTER
PV ARRAY, INVERTER
FEEDER: DROP, RISE, CAP, BREAK, CONTINUATION
POWER - SINGLE LINE DIAGRAM & RISER:
M
PM
ES
NETWORKED POWER METERING/MONITORING
ETHERNET SWITCH
M UTILITY METER, OR TENANT PROVIDED METER
VM CT VOLTAGE SENSOR, CURRENT SENSOR
PM
OS
PEPE
OS
LV P
MK
3 4
L#, F# ; YY
WALL SWITCH: KEY LOCK, MOMENTARY
WALL SWITCH: 3 WAY, 4 WAY
DESIGNATES LUMINAIRE TYPE
(SEE LUMINAIRE SCHEDULE)
YY DENOTES UNIQUE FIXTURE ID
(WHERE DMX CONTROLLED)
ADJUSTABLE ACCENT: MULTILAMP
DOWNLIGHT: SURFACE: SQUARE, ROUND
WALL WASHER: RECESSED: SQUARE, ROUND
PHOTOELECTRIC CELL: WALL
MOUNTED, CEILING MOUNTED
WALL SWITCH: TIMER, MANUAL DIMMER
WALL SWITCH: LOW VOLTAGE, PILOT
WALL SWITCH: 1 POLE, 2 POLE
ADJUSTABLE ACCENT: RECESSED: SQUARE, ROUND
TRACK LIGHTING WITH , WITHOUT CURRENT LIMITER
DT
X
X
DOWNLIGHT: RECESSED: SQUARE, ROUND
EM DESIGNATES EMERGENCY FIXTURE
OCCUPANCY SENSOR: CEILING OR WALL MOUNTED
"X" DESIGNATES DEVICE TYPE:
U: ULTRASONIC
R: INFRARED
DT: DUAL TECHNOLOGY
WALL SWITCH: COMBINATION OCCUPANCY
SENSOR / SWITCH
OS
S S
S S
S S
S S
S
S
S
EMERGENCY NORMAL
WALL WASHER: RECESSED SQUARE, ROUND
ADJUSTABLE ACCENT: SURFACE: SQUARE, ROUND
PENDANT: SQUARE, ROUND
LINEAR: SUSPENDED ASYMMETRIC
LINEAR: SURFACE ASYMMETRIC
LINEAR: SUSPENDED
LINEAR: RECESSED
LINEAR: RECESSED ASYMMETRIC
LINEAR: SURFACE
LINEAR: WALL MOUNTED
LINEAR: WALL MOUNTED ASYMMETRIC
LINEAR: UNDERCABINET
WALL MOUNTED: RECESSED: SQUARE, ROUND
WALL MOUNTED: SURFACE: SQUARE, ROUND
LINEAR ACCENT: ARCHITECTURE INTEGRATED
POLE-MOUNTED: AREA: SQUARE, ROUND
POLE-MOUNTED: STREET: RECTANGULAR, OVAL
POLE-MOUNTED: PEDESTRIAN: SQUARE, ROUND
BOLLARD 360: SQUARE, ROUND
INGRADE SQUARE, ROUND
INGRADE ADJUSTABLE SQUARE, ROUND
FLOOD LIGHT
EXIT SIGN: TOP SURFACE OR TOP RECESSED:
SINGLE , DOUBLE
EXIT SIGN: SIDE OR FLAG MOUNT: SINGLE , DOUBLE
EXIT SIGN: BACK SURFACE MOUNT
BOLLARD 180: SQUARE, ROUND
NA
NA
NA
NA
NA
NA
NA
NA
STRIP LIGHT
LIGHTING LEGEND:
VSD
S
WALL SWITCH COMBINATION OCCUPANCY
SENSOR / DIMMING SWITCH, VACANCY
SENSOR/DIMMING SWITCH
OSD
S
Z# DESIGNATES NORMAL LUMINAIRE ZONE,
DESIGNATES EMERGENCY LUMINAIRE ZONE
(SEE LIGHTING CONTROL SCHEDULE)
Z#E
RC LIGHTING CONTROL RELAY SUGGESTED LOCATION
CS# CONTROL STATION SUGGESTED LOCATION
VS
X
VS
X
DR LIGHTING DRIVER SUGGESTED LOCATION
POWER PACK SUGGESTED LOCATIONPP
NEW, CONNECT TO
STRUCTURAL ENABLING SCOPE IDENTIFIER
NOTE
REPLACE, RELOCATED EXISTING
EXISTING TO REMAIN, EXISTING TO BE REMOVED
NOTE:
THIS IS A STANDARD LEGEND SHEET, THEREFORE, SOME SYMBOLS MAY
APPEAR ON THIS SHEET THAT DO NOT APPEAR ON THE DRAWINGS.
DESIGNATION SYMBOLS:
123.4
E X
RE
C
R
N
1 ####
HARDWIRED CONNECTION, SEE SCHEDULE.
### MECHANICAL/PLUMBING CONNECTION,
SEE SCHEDULE.
ITP
XX
INTEGRATED TECH POLE
FUTUREF
BT BR
/4
/2
G R
A P
H
IC
S C
A L E
-F O
R R
E F
E R
E N
C E
O N
L Y
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".
SUBMITTED BY
DESIGNED BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
DRAWING NO.
TYPE
DISC. SHT. NO.
EAN PAN
NO. DATE BY REVISIONS
A
PP
C A
N Y
O U
S E
E T
H E
A
IR
P L A
N E
S
T
H E
A D
J A
C E
N T
S A
M P
L E
S S
H O
W T
H R
E E
D
IF
F E
R E
N T
L E
V E
L S
O F
S H
A D
IN
G
S
E T
T
IN
G S
F O
R V
IE
W
IN
G
A N
D P
R
IN
T
IN
G D
R A
W
IN
G C
O N
T E
N T
A R
E O
P T
IM
IZ
E D
W H
E N
A L L T
H R
E E
P L A
N E
S A
R E
V
IS
IB
L E
T
H
IS
G U
ID
A
N C
E I S
P R
O V
ID
E
D F
O R
R E
F E
R E
N C
E O
N L Y b la c k g ra y g ra y lig h t d a rk
NO. DATE BY REVISIONS
A
PP
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING
TYPE
D R
A W
IN
G
S C
A L E
I S
R E
D U
C E
D
W H
E N
S H
E E
T S
IZ
E
I S x
B▲ A▲
151 SW 1st Avenue #300 Portland, OR 97204
503.226.2921 pae-engineers.com
7/24/2026 8:43:36 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/26-1037 - PDX Wayfinding MEP25.rvt
SYMBOLS, LEGENDS, & ABBREVIATIONS - ELECTRICAL
PORTLAND INTERNATIONAL AIRPORT
E0.001
AUGUST 2026
G. PARTHEMER
P. MARKS
D. PEEK
JAY OSTLUND
TERMINAL AND CONCOURSES WAYFINDING SIGNAGE
PDX 2026-512
CD
1031012026D004
1. ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN AS
HALFTONE ARE EXISTING TO REMAIN, UNLESS NOTED.
2. ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN AS
FULL-TONE ARE NEW, UNLESS OTHERWISE NOTED
3. INTERIOR RACEWAY SHALL BE CONCEALED WHEN LOCATED
WITHIN FINISHED SPACES UNLESS NOTED.
4. RACEWAY SHALL BE IN CEILING UNLESS NOTED.
5. REFER TO ARCHITECTURAL CEILING PLANS, ELEVATIONS, AND
FLOOR PLANS FOR LOCATIONS OF CEILING, WALL, AND FLOOR
MOUNTED DEVICES AND EQUIPMENT. WHERE INTERIOR
ELEVATIONS DIFFER BETWEEN ARCHITECTURAL AND
ENGINEERING DRAWINGS, NOTIFY THE PORT.
6. THE FIRE ALARM SYSTEM IS A CONTRACTOR DESIGN-BUILD
SYSTEM. SELECT DEVICES ARE SHOWN FOR COORDINATION.
PROVIDE REQUIRED DEVICES TO COMPLY WITH CODE
THROUGHOUT REMODELED SPACES. CONTRACTOR SHALL
PROVIDE FIRE ALARM/VOICE EVACUATION DEVICES,
ACCESSORIES AND ALL ADDITIONAL ITEMS REQUIRED FOR A
COMPLETE AND OPERATIONAL CODE COMPLIANT SYSTEM.
CONDUIT ROUTING, SIZING, AND QUANTITIES. REFERENCE
SPECIFICATION DIVISION 28 46 00 FOR ADDITIONAL
INFORMATION.
7. PROVIDE FLEXIBLE CONDUIT CONNECTIONS NEAR EXPANSION
JOINTS FOR CONDUITS THAT CROSS SEISMIC EXPANSION
JOINTS REFER TO STRUCTURAL DRAWINGS FOR SEISMIC
JOINT LOCATIONS.
8. DIVISION 26 TO PROVIDE FIRESTOPPING AT PENETRATIONS
THROUGH RATED STAIR ENCLOSURES, RATED EGRESS
CORRIDORS, RATED SHAFTS, FLOOR AND CEILING ASSEMBLIES
IN ACCORDANCE WITH DIVISION 07.
9. REFER TO SPECIFICATION 26 05 53 FOR PORT STANDARD
IDENTIFICATION AND LABELING REQUIREMENTS OF
ELECTRICAL EQUIPMENT.
NOTE(S):
ELECTRICAL PLAN SHEETS
1. ELECTRICAL EQUIPMENT, DEVICES AND FEEDER SHOWN AS
HALFTONE ARE EXISTING TO REMAIN, UNLESS OTHERWISE
NOTED.
2. WHERE ALL LOAD IS REMOVED FROM A CIRCUIT, THE CONDUIT,
CONDUCTOR AND HANGERS SHALL BE REMOVED IN ENTIRETY
BACK TO THE SOURCE PANEL. WHERE CONDUIT IS
CONCEALED, REMOVE CONDUCTORS AND ABANDON CONDUIT.
3. REMOVE BRANCH CIRCUITING ASSOCIATED WITH ITEMS
IDENTIFIED FOR DEMOLITION. PROVIDE CONDUIT AND
CONDUCTORS TO MAINTAIN CONNECTION TO ALL ITEMS THAT
REMAIN WHERE SERVICE IS INTERRUPTED WITH DEMOLITION.
4. ALL DEMOLITION ITEMS SHOWN ARE BASED UPON RECORD
DRAWINGS AND SITE OBSERVATIONS, NOT ALL DEVICES MAY
BE SHOWN.
5. REMOVE ALL BRANCH CIRCUITING AND HANGERS ASSOCIATED
WITH ITEMS SHOWN FOR DEMOLITION.
6. AFTER REMOVAL OF ELECTRICAL SYSTEMS, RESTORE
DAMAGED SURFACES AND FINISHES TO MATCH EXISTING.
7. THE FIRE ALARM SYSTEM IS CONTRACTOR DESIGN-BUILD.
CONTRACTOR TO IDENTIFY ALL FIRE ALARM SYSTEM
COMPONENTS AND SYSTEMS FOR DEMOLITION, AND PROVIDE
DEMOLITION SHOP DRAWINGS. PROVIDE AND INDICATE
SYSTEM RE-ROUTES AND TEMPORARY SYSTEM INTERIM
CONDITIONS UNTIL PDX 2021-510 COMPLETED SYSTEM SHOP
DRAWINGS ARE AVAILABLE AND SYSTEM BUILD OUT CAN BE
COMPLETED.
NOTE(S):
DEMOLITION PLAN SHEETS
1. REFER TO ONE-LINE DIAGRAM OR PANEL SCHEDULES FOR
OVERCURRENT PROTECTION CHARACTERISTICS AND CIRCUIT
NUMBERS.
2. COORDINATE EQUIPMENT CONNECTION REQUIREMENTS WITH
INSTALLING CONTRACTOR PRIOR TO PERFORMING ANY
ELECTRICAL WORK.
3. COMBINATION STARTER/DISCONNECTS AND DISCONNECT
SWITCHES SHALL BE LOCATED WITHIN SIGHT OF AND
ADJACENT TO EQUIPMENT SERVED. COORDINATE
DISCONNECT INSTALLATION AND LOCATION WITH EQUIPMENT
INSTALLER.
4. EQUIPMENT LOCATIONS ARE SHOWN ON ELECTRICAL
DRAWINGS FOR REFERENCE, BUT MAY NOT INCLUDE EVERY
ITEM LISTED IN SCHEDULE. LOCATIONS SHOWN ON OTHER
DISCIPLINE DRAWINGS TAKE PRECEDENCE.
NOTE(S):
EQUIPMENT CONNECTION SCHEDULE SHEETS
1. ALL ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN
AS HALFTONE ARE EXISTING TO REMAIN, UNLESS OTHERWISE
NOTED.
2. ALL ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN
AS SOLID DASH ARE DEMOLITION, UNLESS OTHERWISE NOTED.
3. DEMOLISHED ITEMS SHOWN AND ASSOCIATED FEEDERS,
CONDUIT, CONDUCTORS AND HANGERS SHALL BE REMOVED IN
THEIR ENTIRETY.
4. REFER TO SPECIFICATION FOR EQUIPMENT TO BE SALVAGED
AND RETURNED TO PORT.
5. ALL ELECTRICAL EQUIPMENT, DEVICES AND FEEDERS SHOWN
AS SOLID ARE NEW, UNLESS OTHERWISE NOTED.
NOTE(S):
ONE LINE SHEETS
1. ALL BRANCH CIRCUITS SHOWN IS EXISTING TO REMAIN,
UNLESS OTHERWISE NOTED.
2. ALL DEMOLISHED BRANCH CIRCUITS SHALL HAVE BREAKER
TURNED OFF AND MARKED AS SPARE WITHIN PANEL
DIRECTORY.
NOTE(S):
PANEL SCHEDULE SHEETS
L
R E
N
G
O
R
I
E
I
S
ST
S
E
E
N
ER
F
E
E
G
OD R
N
EXPIRES: 12/31/2026
P
A
I
44775PE
OREGONJ
U L Y 13 , 19 9
9G R
A
NT R. PA RTHEM
E R grant.parthemer Text Box 7/24/26
| 2026-07-24T10:06:45-0700 | |
| Grant Parthemer |
File details come from the government source that posted it. Updated .