PDX 2026-512 (35) S6.111.pdf

PDF 160 KB Posted

Attached to
Portland International Airport Terminal and Concourses Wayfinding Signage (Re-Bid)
Solicitation number
146219
Issued by
Multnomah County, Oregon

About this file

This is a structural detail drawing for the Portland International Airport Terminal and Concourses Wayfinding Signage project, prepared by Jay Ostlund Architects for the City of Portland, Oregon. The drawing, designated as Sheet S6.111, provides specifications for hanging sign cable support systems to be installed throughout the terminal and concourse areas. The design accommodates signs with a maximum weight of 800 pounds, utilizing 3/16-inch diameter stainless steel cable pairs at each sign support point with a minimum breaking load of 2,400 pounds. The cable connection hardware is based on the Ronstan system or approved equivalents and must accommodate full rotation in two primary directions. The drawing includes two typical cable support configurations with detailed cross-sections (Sections A-A and B-B) showing attachment methods to existing truss members and bridging elements through threaded studs and welded plates. The document was submitted on July 21, 2026, and includes signature lines indicating approval from multiple project stakeholders.

The specification requires exposed steel and welding to meet AESS standards and mandates that all existing steel be properly prepared for welding while matching existing conditions with new plates. The design incorporates hinged cable connections at both the top and bottom of signage elements to allow for movement and accommodation of existing building structures. No additional information regarding pricing, contract terms, incumbent contractors, or funding sources is contained within this structural detail drawing. The drawing was current as of August 2026 and expires December 31, 2026, with an extended expiration date of June 30, 2028 noted on the document.

View the file

Other files

File Type Posted
PDX 2026-512 (17) S2.253.pdf PDF
PDX 2026-512 (181) G2.273.pdf PDF
PDX 2026-512 (08) S0.003.pdf PDF
PDX 2026-512 (85) E9.004.pdf PDF
PDX 2026-512 (174) G2.260.pdf PDF
PDX 2026-512 (128) G2.071.pdf PDF
PDX 2026-512 (39) E0.002.pdf PDF
PDX 2026-512 (95) T2.200.pdf PDF
PDX 2026-512 (67) E2.740.pdf PDF
PDX 2026-512 (159) G2.202.pdf PDF
PDX 2026-512 (222) G9.117.pdf PDF
PDX 2026-512 (139) G2.131.pdf PDF
PDX 2026-512 (96) T2.252.pdf PDF
PDX 2026-512 (28) S2.370.pdf PDF
PDX 2026-512 (163) G2.221.pdf PDF
PDX 2026-512 (148) G2.153.pdf PDF
PDX 2026-512 (18) S2.270.pdf PDF
PDX 2026-512 (103) G0.002.pdf PDF
PDX 2026-512 (43) E1.200.pdf PDF
PDX 2026-512 (93) T2.153.pdf PDF
PDX 2026-512 (115) G2.025.pdf PDF
PDX 2026-512 (145) G2.143.pdf PDF
PDX 2026-512 (229) G9.124.pdf PDF
PDX 2026-512 (122) G2.053.pdf PDF
PDX 2026-512 (197) G2.371.pdf PDF
PDX 2026-512 (65) E2.700.pdf PDF
PDX 2026-512 (241) G9.136.pdf PDF
PDX 2026-512 (164) G2.222.pdf PDF
PDX 2026-512 (179) G2.271.pdf PDF
PDX 2026-512 (149) G2.160.pdf PDF
PDX 2026-512 (196) G2.363.pdf PDF
PDX 2026-512 (215) G9.110.pdf PDF
PDX 2026-512 (165) G2.231.pdf PDF
PDX 2026-512 (202) G2.442.pdf PDF
PDX 2026-512 (146) G2.151.pdf PDF
PDX 2026-512 (177) G2.263.pdf PDF
PDX 2026-512 (240) G9.135.pdf PDF
PDX 2026-512 (140) G2.131.pdf PDF
PDX 2026-512 (31) S2.373.pdf PDF
PDX 2026-512 (73) E2.771.pdf PDF
PDX 2026-512 (75) E2.773.pdf PDF
PDX 2026-512 (238) G9.133.pdf PDF
PDX 2026-512 (05) GI4.000.pdf PDF
PDX 2026-512 (198) G2.372.pdf PDF
PDX 2026-512 (214) G9.109.pdf PDF
Substitution Request Form.pdf PDF
PDX 2026-512 (162) G2.212.pdf PDF
PDX 2026-512 (201) G2.431.pdf PDF
PDX 2026-512 (0) Re-Bid COVER.pdf PDF
PDX 2026-512 (168) G2.241.pdf PDF
Show 40 more

Latest 50 of 248 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SIGN (BY OTHERS)

SEE S6.110

CABLE CONNECTION

(BY OTHERS) TOP AND

BOT. W/ HINGES IN TWO

PRIMARY DIRECTION TYP.

SEE NOTE 3

3/16" DIA. SS CABLE

PAIR AT EACH SIGN

SUPPORT POINT (2)

CABLE PAIRS MIN. PER

SIGN. SEE NOTE 2

3 1/4"

THREADED STUD

TO MATCH CABLE

CONNECTION NO

GAP AT PLATE

PROVIDE WASHER/

SHIM AS REQ'D.

(2) PL 1/2x2 1/2x0'-5"

THEADED STUDS FOR

HANGER. TAP INTO

SIGN BY OTHERS

(E) PLATE ON

BOTTOM OF WT

SECTION

(E) TRUSS WT

BOT. CHORD

V.I.F.

3/16

3/16THREADED STUDS

FOR HANGER. TAP

AND THREAD INTO PL

A

A

(E) TRUSS WT

BOT. CHORD

SECTION A-A

EQ EQ

(E) PLATE ON

BOTTOM OF

TRUSS

B

B

SECTION B-B

NOTE(S):

1. EXPOSED STEEL AND WELDING IS AESS. SEE GSN.

2. BASIS OF DESIGN CABLE, TURNBUCKLE, SWIVEL AND HARDWARE

IS RONSTAN SYSTEM. MIN BREAKING LOAD OF 2,400LBS. PROVIDE

RONSTAN SYSTEM OR APPROVED EQUAL .

3. CABLE CONNECTION HARDWARE SHALL BE ABLE TO ACCOMMODATE

FULL ROTATION IN TWO DIRECTIONS.

4. PREP EXISTING STEEL AS REQUIRED FOR WELDING AND MATCH

EXISITNG CONDITIONS WITH NEW PLATES. SEE SIGNAGE.

3/16

3/16

SIGN (BY OTHERS)

800 LBS MAX. WEIGHT

CABLE CONNECTION

(BY OTHERS) TOP AND

BOT. W/ HINGES IN TWO

PRIMARY DIRECTION TYP.

SEE NOTE 3

3/16" DIA. SS CABLE

PAIR AT EACH SIGN

SUPPORT POINT (2)

CABLE PAIRS MIN. PER

SIGN. SEE NOTE 2

3 1/4"

THREADED STUD

TO MATCH CABLE

CONNECTION NO

GAP AT PLATE

PROVIDE WASHER/

SHIM AS REQ'D.

PLATE SEE

ELEVATION

3/16 4-16

3/16 4-16

THREADED STUDS

FOR HANGER. TAP

AND THREAD INTO PL

A

A

(E) TRUSS

BRIDGING

MEMBER

B

B

SECTION A-A

SECTION B-B

PLATE

SEE ELEVATION

NOTE(S):

1. EXPOSED STEEL AND WELDING IS AESS. SEE GSN.

2. BASIS OF DESIGN CABLE, TURNBUCKLE, SWIVEL AND HARDWARE

IS RONSTAN SYSTEM. MIN BREAKING LOAD OF 2,400LBS. PROVIDE

RONSTAN SYSTEM OR APPROVED EQUAL .

3. CABLE CONNECTION HARDWARE SHALL BE ABLE TO ACCOMMODATE

FULL ROTATION IN TWO DIRECTIONS.

4. PREP EXISTING STEEL AS REQUIRED FOR WELDING AND MATCH

EXISITNG CONDITIONS WITH NEW PLATES. SEE SIGNAGE.

THEADED STUDS FOR

HANGER. TAP INTO

SIGN BY OTHERS

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲

7/21/2026 2:35:47 PM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX-103101-STR_Signage-Walkway.rvt

SIGNAGE DETAILS - HANGING SIGNS - 2 - STRUCTURAL

PORTLAND INTERNATIONAL AIRPORT

S6.111

AUGUST 2026

A. MONNIER

J. DE BOER

S. THOMAS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

PDX 2026-512

CD

1031012026D004

35111 SW Fifth Ave., Suite 2600 Portland, OR 97204 O 503.227.3251 - F 503.227.7980

SCALE: 3" = 1'-0"1

CABLE SUPPORT AT SIGNAGE (TYPICAL)

SCALE: 3" = 1'-0"2

CABLE SUPPORT AT SIGNAGE (PERP. ORRIENTATION )

EXPIRES 12/31/202606/30/2028

7/27/2026

2026-07-27T15:43:53-0700
James Vodden

File details come from the government source that posted it. Updated .