The document is a comprehensive Parks & Recreation Sign Standards manual for Pierce County, Washington, detailing comprehensive design guidelines for park signage across vehicular and pedestrian scales. The manual provides detailed specifications for various sign types including park entry, directional, mile markers, park information, playground rules, trail entry, and general signs. The standards cover graphic design elements, material specifications, color usage, symbol libraries, mounting requirements, and foundation details. The document was originally created on 02/23/2017 and has been updated multiple times, with the most recent update noted as 06/01/2025.

The manual specifies precise technical requirements for sign construction, including recommended materials like Corten steel panels, aluminum, specific paint colors (using Pantone 7701, 7741, and 7579), and mounting techniques. It provides detailed structural design criteria including live load, wind load, and seismic considerations, with specific requirements for concrete strength, reinforcing materials, and anchor bolt specifications. The sign standards aim to create a consistent, recognizable visual identity for Pierce County Parks & Recreation, with careful attention to typography (using Helvetica Neue), symbol design, and color usage that ensures readability and aesthetic cohesion across different sign types and park environments.

View the file

Other files

File Type Posted
2025-ITB-063_Parks_On-Call_Signage.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PARKS & RECREATION - SIGN STANDARDS

SECTION 1 Graphic Standards

SECTION 2 Materials & Finishes

SECTION 3 Sign Types

Original: 02/23/2017 Updated: 09/07/2021

JYouell Text Box

ADDENDUM 1

JYouell Line

JYouell Line

JYouell Text Box Sign Footing Details

JYouell Line

JYouell Text Box Updated 06/01/2025

SECTION 1 - GRAPHIC STANDARDS

1.2 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

Left Up/Forward Right

Left & Back Forward & Left Down Right & Back Forward & Right

TYPEFACE FAMILY

The Helvetica family, known for its classic simplicity and readability, has been selected for the sign standards program.

Headings Text: Helvetica Neue 75 Bold

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890?!”$&

Secondary Text: Helvetica Neue 55 Roman

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890?!”$&

LETTER-HEIGHTS

Wherever possible, the following minimum letter-heights have been selected for the program:

Vehicular Scale Signs Headings: 4” min. Secondary: 3” min.

Interpretive & Info. Text Signs Headings: 60 pt. min. Secondary: 16 pt. min.

ARROWS

The following arrow styles have been selected for use in the sign standards program.

JYouell

Updated: 06/01/2025

1.3 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

SYMBOLS

The following symbols have been selected for use in the sign standards program. Whenever possible, the symbols should be accompanied by the nomenclature shown on the chart below. See General Layouts this section for more detail on location and placement.

Access Amphitheater Baseball/Softball Basketball Beach BMX

Boat Launch Camping Climbing Wall Community Center Community Garden Concessions

Cycling Disc Golf Dog Leash & Scoop Dog Park First Aid Golf

Hiking Horse Trail Men Parking Picnic Area Picnic Shelter

Playground Restroom/Toilet Skate Park Soccer Swimming Tennis

Women

JYouell

1.4 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

SYMBOLS Contd.

No Alcohol No ATVs No Camping No Cycling No Dogs No Entry

No Firearms No Fires No Fireworks No Food No Golf/Archery No Horses

No Metal Cleats No Parking No Personal Aircraft No Smoking No Stakes No Vehicles

JYouell

1.5 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

GENERAL LAYOUT

The following layouts are a general guide for the scale and relationship between text, arrows and symbols throughout the sign standards program.

COLOR USE

The following general use applies to color throughout the program. Keep in mind the statement “blue means you’re there, green is informational or how to get there.”

Pantone 7701 Use as a general background color for signs that display the users actual point of location: park name, facility name, Pierce County Parks Name and Logo, mile marker, etc. Use as a background with only white lettering/graphics preferred.

Pantone 7741 Use as a background for all specific directional or parks information items: icons, arrows, etc. Use as a background with only white lettering/graphics preferred.

Pantone 7579 Use as a background as secondary directional or parks information items. Use as a background with only white lettering/graphics preferred.

DOG PARK

PLAYGROUND

PARKING

X X

X .5

X .5

X .5

X .5

X 1.25X1.25X .5X.25X.5X

M

AT

C H

S C

A

LE

C

E N

TE

R

INFORMATION HIERARCHY: List destinations with closest distance to sign first, next closest second, etc.

JYouell

SECTION 2 - MATERIALS & FINISHES

2.1 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PAINT

Code Swatch Type Brand Specification Finish Notes

PT1 Paint Matthews Paint MP 13912 Soda Can Blue

Satin + UV & Graffiti Resistance Clear Coat

Pierce County Logo Blue Pantone 7461

PT2 Paint Matthews Paint MP 12106 Fordson Blue

Satin + UV & Graffiti Resistance Clear Coat Pantone 7701

PT3 Paint Matthews Paint MP 14748 Tucuman Parrot Green

Satin + UV & Graffiti Resistance Clear Coat Pantone 7741

PT4 Paint Matthews Paint MP 32071 White Wonder

Satin + UV & Graffiti Resistance Clear Coat

PT5 Paint Matthews Paint MP 07102 Deep River

Satin + UV & Graffiti Resistance Clear Coat

PT6 Paint Matthews Paint MP 10429 Orange Nature

Satin + UV & Graffiti Resistance Clear Coat Pantone 7579

PT21 Powder Coat Black Satin w/ Graffiti Resistant Properties

PT22 Powder Coat Match to: RAL 5009 Azurblau

Satin w/ Graffiti Resistant Properties

PT23 Powder Coat Match to: RAL 6010 Grasgrün

Satin w/ Graffiti Resistant Properties

PT24 Powder Coat Match to: RAL 2010 Signalorange

Satin w/ Graffiti Resistant Properties

VINYL & GRAPHIC FILM

Code Swatch Type Brand Specification Finish Notes

VNL1 Vinyl 3M Engineer Grade Prismatic Reflective Sheeting 3430 White

Reflective

VNL2 Vinyl 3M 7725-20 Matte White Matte

GFM1 N/A Graphic Film 3M Controltac Graphic Film IJ180-10 Luster with Overlaminate

LAMINATE

Code Swatch Type Brand Specification Finish Notes

CHPL1 N/A

Custom High Pressure Laminate

.048” Thickness Ice + Seal Edges to Prevent Water Damage

CHPL2 N/A

Custom High Pressure Laminate

.5” thickness (Self Supporting)

Ice + Seal Edges to Prevent Water Damage

Drilled and threaded at back for mechanical attachment hardware

JYouell

2.2 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

METAL

Code Swatch Type Brand Specification Finish Notes

MTL1 N/A Aluminum Panel 1/8” thick

MTL2 N/A Corten Steel Panel 1/8” thick Pre-Patina Preferred

Where Available

MTL3 N/A Corten Steel Panel 1/2” thick Pre-Patina Preferred

Where Available

MTL10 N/A Square Metal Post 6” x 6” Powder Coated Welded Caps

MTL11 N/A Square Metal Post 4” x 4” Powder Coated Welded Caps

MTL12 N/A Square Metal Post 2” x 2” Powder Coated Welded Caps

MTL20 N/A Corten Angle 4” x 3”; 1/4” thick Pre-Patina Preferred Where Available

Grind Down/Round All Exposed Edges

MTL21 N/A Corten Tube 2” x 2”; 1/8” thick Pre-Patina Preferred Where Available

Grind Down/Round All Exposed Edges

JYouell Text Box Updated: 06/01/2025

JYouell Image

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell

First Surface/Direct Print;

2.3 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PREFERRED MOUNTING BY SIGN TYPE

Sign Type Surface Mount to Cast-in-Place Footing(s)

Embedded Other

VEHICULAR SCALE SIGNS

Park Entry X Directional X Mile Marker X General Signs X X

PEDESTRIAN SCALE SIGNS

Park Entry X Park Info. & Rules X Playground Info. & Rules X Directional X Mile Marker X Interpretive X X Map X X Trail Entry - Large X Trail Entry - Small X X Trail Directional X X General Signs X X

JYouell

PIERCE COUNTY

PARKS & RECREATION

FIRST LINE

SECOND LINE

PIERCE COUNTY

PARKS & RECREATION

FIRST LINE

SECOND LINE

MERIDIAN

HABITAT PARK

THIRD LINE SPACE

PIERCE COUNTY

PARKS & RECREATION

FIRST LINE

FIRST LINE OPT.

SECOND LINE

PIERCE COUNTY

PARKS & RECREATION

FIRST LINE

FIRST LINE OPT.

SECOND LINE

FI

R S

T L

IN

E

30” x 54”

INFORMATIONAL

PANEL

PIERCE COUNTY

PARKS & RECREATION

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1ARROW

IC

ON

LINE 1 OPT.

ARROW

IC

ON

OPTIONAL

12” x 21”

MAP OR

INFO. PANEL

OPTIONAL

12” x 21”

MAP OR

INFO. PANEL

LINE 1ARROW

LINE 1ARROW

LINE 1ARROW

LINE 1ARROW

T R

IL

N

E MILE

T R

IL

N

E

MILE

27” x 51”

INFORMATIONAL

PANEL

PIERCE COUNTY

PARKS & RECREATION

MILE

MILE

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1IC

ON

ARROW

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1ARROW

IC

ON

LINE 1 OPT.

ARROW

IC

ON

LINE 1ARROW

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

PIERCE COUNTY

PARKS & RECREATION

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

PARK NAME

SECOND LINE

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADER TEXT

HEADER TEXT HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

PIERCE COUNTY

PARKS & RECREATION

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

PARK NAME

SECOND LINE

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADER TEXT

HEADER TEXT HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

ARTWORK PANEL

15” x 48”

INFO.

PANEL

SECTION 3 - SIGN TYPES

3.1 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PARK ENTRY

PARK

INFO. & RULES

TRAIL ENTRY -

LARGE

TRAIL ENTRY -

SMALL

PARK ENTRY PLAYGROUND

INFO & RULES

DIRECTIONAL

TRAIL

DIRECTIONAL

DIRECTIONAL

INTERPRETIVE MAP

MILE

MARKER

GENERAL SIGNS

GENERAL

SIGNS

PEDESTRIAN SCALE SIGNS

VEHICULAR SCALE SIGNS

MILE

MARKER

ARTWORK PANEL

JYouell

NOTES

• All signs in public ROW must conform with

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

MERIDIAN

HABITAT PARK

THIRD LINE SPACE

PIERCE COUNTY

PARKS & RECREATION

FIRST LINE

FIRST LINE OPT.

SECOND LINE

PIERCE COUNTY

PARKS & RECREATION

FIRST LINE

FIRST LINE OPT.

SECOND LINE

8’

- 0

12”6’- 9” STREET

2.5” 8”

6’- 0”

1’- 3” 5’- 4”

1.84”

2.

5”

5” 8”

2.

5”

5” 2.

5” 5”

2.

5”

5” 3”

3” 8”

1.5 ”1

.5

4”

3.5” 3.5”

FIRST LINE OPTION:

Start first line here ONLY if three (3) lines are needed

STREET

SECTION 3 - SIGN TYPES

3.2 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

VNL1

MTL2

MTL2

FABRICATED BOX

“PEAK ELEMENT”

FABRICATED

BOX ELEMENT

SYMBOL

SQUARES

FABRICATED

BOX ELEMENT

FABRICATED BOX

“PEAK ELEMENT”

MTL1

PT2

MTL1

PT2

MTL1

PT3

VNL1

CONCRETE BASE IN

APPROPRIATE FOOTING.

NOTE: FABRICATED BOX

ELEMENTS TO BE SURFACE

MOUNTED TO CONCRETE

BASE, NOT EMBEDDED.

GUTTER TO

CHANNEL BLEED

FROM MTL2

GUTTER TO

CHANNEL BLEED

FROM MTL2;

CREATE SLIGHT

SLOPE AT

HORIZONTAL

SECTION TO

PROMOTE

DRAINAGE

VEHICULAR SCALE - PARK ENTRY

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1ARROW

IC

ON

LINE 1 OPT.

ARROW

IC

ON

1’ - 3”

8”

2’- 9”

STREET

6”6”

SECTION 3 - SIGN TYPES

3.3 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

VEHICULAR SCALE - DIRECTIONAL

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

MTL10

PT21

MTL1

PT3

MTL1

PT2

MTL1

PT3

MTL10

PT21

VNL1

MTL1

PT2

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1ARROW

IC

ON

LINE 1 OPT.

ARROW

IC

ON

LINE 1ARROW

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

1’ - 3”

8”

2’- 9”

STREET

1’ - 3” 6”

STREET

6”

SECTION 3 - SIGN TYPES

3.4 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

VEHICULAR SCALE - DIRECTIONAL - INTERSECTION OPTION

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

MTL1

PT2

MTL1

PT3

MTL1

PT2

MTL1

PT3

MTL10

PT21

VNL1

MTL10

PT21

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

MILE

4” 3”

2’

9” 1”

4”

6”1”

SECTION 3 - SIGN TYPES

3.5 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

VEHICULAR SCALE - MILE MARKER

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

MTL20

MTL1

PT2

VNL1

MTL1

PT2

VNL1

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

PIERCE COUNTY

PARKS & RECREATION

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

PARK NAME

SECOND LINE

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADER TEXT

HEADER TEXT HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

3”

4” 3”

4” 3”

3”

4” 3”

4’ - 8” 4’ - 8”

3’ - 0”

1”

D

IM

E

N S

IO

N

V A

R

IE

S B

A S

E D

O N

C O

N

TE

N T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N L

O C

AT

IO

N

C O

N

TE

N T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N C

O N

TE

N

T D

IM

E

N S

IO

N

V A

R

IE

S B

A S

E D

O N

L O

C

AT

IO

N

C

O N

TE

N

T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N C

O N

TE

N

T D

IM

E

N S

IO

N

V A

R

IE

S B

A S

E D

O N

L O

C

AT

IO

N

C

O N

TE

N

T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N C

O N

TE

N

T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N C

O N

TE

N

T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N L

O C

AT

IO

N

C O

N

TE

N T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N L

O C

AT

IO

N

C O

N

TE

N T

6”

HEADER TEXT

HEADER TEXT

FOR CONTENT LAYOUT GUIDELINES

SEE SECTION 1 - GRAPHIC STANDARDS

SECTION 3 - SIGN TYPES

3.6 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

VEHICULAR SCALE - GENERAL SIGNS

MTL1

PT2

VNL1

MTL12

PT21

or

WALL

MOUNT

TYPE A TYPE B TYPE C

CORNER

RADIUS

.375” TYP.

MTL1

PT3 or PT6

VNL1

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

PIERCE COUNTY

PARKS & RECREATION

FIRST LINE

SECOND LINE

PIERCE COUNTY

PARKS & RECREATION

FIRST LINE

SECOND LINE

6’

3”

6”5’- 0” STREET

2” 6”

4’ - 6”

1’- 3” 4’- 0”

1.38”

2” 2”

2” 6”

4” 4”

4” 4”

2” 2.

2.

6”

1.1

1.1

.5”

2.5” 2.5”

STREET

FIRST LINE OPTION:

Start first line here ONLY if three (3) lines are needed

SECTION 3 - SIGN TYPES

3.7 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - PARK ENTRY

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

VNL1

MTL3

MTL3

FABRICATED

BOX ELEMENT

FABRICATED

BOX ELEMENT

MTL1

PT2

MTL1

PT2

MTL10

PT21

MTL1

PT3

VNL1

GUTTER TO

CHANNEL BLEED

FROM MTL3

GUTTER TO

CHANNEL BLEED

FROM MTL2;

CREATE SLIGHT

SLOPE AT

HORIZONTAL

SECTION TO

PROMOTE

DRAINAGE

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

FI

R

S T

L

IN

E

30” x 54”

INFORMATIONAL

PANEL

PIERCE COUNTY

PARKS & RECREATION

7’

6”1’- 4”

2’- 0”

2”2”

2” 2”

M in

R ig ht

J us tifi ed

T ex t)

4” 2” 2” 2”4”

6”

1’- 0” 5’- 6”

3’- 10”

SECTION 3 - SIGN TYPES

3.8 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - PARK INFO. & RULES

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

EXPANSION OPTION

Scale = 1/4” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

VNL2

GFM1

OR

CHPL1

MTL10

PT 21

IN APPROPRIATE

FOOTINGS

MTL3

ROUTED

LETTERING

TO EXPOSE

MTL3 BEHIND

MTL3 MTL1

PT5

MTL1

PT5

MTL1

PT2

3/4” STANDOFF1/4” STANDOFF

MTL1

PT2

FI

R

S T

L

IN

E

30” x 54”

RULES & INFO.

SIGN PANEL

PIERCE COUNTY

PARKS & RECREATION

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

15” x 48”

INFO.

PANEL

7’

” 5’

4”9”

1’- 3”

1.5”

1.5”

1’- 6”

1’

5”

SECTION 3 - SIGN TYPES

3.9 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - PLAYGROUND INFO. & RULES

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

VNL2

GFM1

OR

CHPL1

MTL11

PT21

IN APPROPRIATE

FOOTING

MTL3

MTL3

MTL11

PT21

MTL1

PT5

1/4” STANDOFFS

MTL1

PT2

CORNER

RADIUS

.375” TYP.

CORNER

RADIUS 3”

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1ARROW

IC

ON

LINE 1 OPT.

ARROW

IC

ON

OPTIONAL

12” x 21”

MAP OR

INFO. PANEL

6’

1’

1”

1’ - 0” 4”

4” 7”

2’- 0”

1’- 2”

PATH

9’

9”

6”

SECTION 3 - SIGN TYPES

3.10 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - DIRECTIONAL

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

VNL2

MTL1

PT3

MTL1

PT2

GFM1

OR

CHPL1

MTL11

PT21

IN APPROPRIATE

FOOTING

MTL11

PT21

MTL1

PT3

MTL1

PT2

MTL1

PT3

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1ARROW

IC

ON

LINE 1 OPT.

ARROW

IC

ON

OPTIONAL

12” x 21”

MAP OR

INFO. PANEL

OPTIONAL

12” x 21”

MAP OR

INFO. PANEL

LINE 1ARROW

LINE 1ARROW

LINE 1ARROW

LINE 1ARROW

9’

” 1’

1”

1’ - 0” 1’ - 0”

4”

9”

6”

7” 2’- 0”

PATH

4”

6’

1’- 2”

SECTION 3 - SIGN TYPES

3.11 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - DIRECTIONAL - INTERSECTION OPTION

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

VNL2

MTL1

PT3

MTL1

PT2

GFM1

OR

CHPL1

MTL11

PT21

MTL11

PT21

MTL1

PT3

MTL1

PT3 MTL1

PT2

MTL1

PT3

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

MILE

4”

2’

7” 1”

3”

1” 4”

1” 4”

3”

SECTION 3 - SIGN TYPES

3.12 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - MILE MARKER

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

MTL20

MTL20

MTL1

PT2

VNL2

MTL1

PT3

VNL2

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

ARTWORK PANEL

3’

1”

2’

3”

SECTION 3 - SIGN TYPES

3.13 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - INTERPRETIVE

FRONT ELEVATION

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

PT22

IZONE IMAGING

CLCB3624IN

CLASSIC SIGN FAMILY

BRACKET POST - CANTILEVER

W/ CHPL PANEL

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

ARTWORK PANEL

3’

1”

2’

3”

SECTION 3 - SIGN TYPES

3.14 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - MAP

FRONT ELEVATION

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

PT23

IZONE IMAGING

CLCB3624IN

CLASSIC SIGN FAMILY

BRACKET POST - CANTILEVER

W/ CHPL PANEL

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

27” x 51”

INFORMATIONAL

PANEL

PIERCE COUNTY

PARKS & RECREATION

4”9”

1’- 3”

1.5”

1.5”

2’- 6”

7’

” 5’

1’

5”

SECTION 3 - SIGN TYPES

3.15 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - TRAIL ENTRY - LARGE

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

VNL2

GFM1

OR

CHPL1

MTL3

MTL3

MTL1

PT3

MTL1

PT5MTL11

PT21

MTL11

PT21

1/4” STANDOFF 3/4” STANDOFF

MTL1

PT2

MTL1

PT5

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

T R

IL

N

E MILE

T R

IL

N

E

MILE

4’

1’ - 0”

4” 3”

3’

5”

2”

9”

PATH PATH

SECTION 3 - SIGN TYPES

3.16 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - TRAIL ENTRY - SMALL

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

REAR ELEVATION

Scale: 1/2” = 1’-0”

VNL2

MTL1

PT3

VNL2

MTL3

ROUTED

LETTERING

TO EXPOSE

MTL3

BEHIND

MTL12

PT21

MTL12

PT21

1/4” STANDOFF

MTL1

PT2

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1IC

ON

ARROW

2”

1’ - 3”

3’

.5”

.5

SECTION 3 - SIGN TYPES

3.17 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - TRAIL DIRECTIONAL

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

MTL21

MTL21

MTL1

PT3 or PT6

VNL2

MTL1

PT3

VNL2

CORNER

RADIUS

.375” TYP.

JYouell

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

PIERCE COUNTY

PARKS & RECREATION

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

PARK NAME

SECOND LINE

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADER TEXT

HEADER TEXT HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

HEADINGARROW

IC

ON

Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

HEADING

Secondary Text

Lorem ipsum dolor sit amet, consectetur adipiscing elit.

3”

4” 3”

4” 3”

3”

4” 3”

4’ - 8” 4’ - 8”

3’ - 0”

1”

D

IM

E

N S

IO

N

V A

R

IE

S B

A S

E D

O N

C O

N

TE

N T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N L

O C

AT

IO

N

C O

N

TE

N T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N C

O N

TE

N

T D

IM

E

N S

IO

N

V A

R

IE

S B

A S

E D

O N

L O

C

AT

IO

N

C

O N

TE

N

T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N C

O N

TE

N

T D

IM

E

N S

IO

N

V A

R

IE

S B

A S

E D

O N

L O

C

AT

IO

N

C

O N

TE

N

T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N C

O N

TE

N

T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N C

O N

TE

N

T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N L

O C

AT

IO

N

C O

N

TE

N T

D

IM

E N

S

IO

N V

A R

IE

S

B A

S E

D O

N L

O C

AT

IO

N

C O

N

TE

N T

6”

HEADER TEXT

HEADER TEXT

SECTION 3 - SIGN TYPES

3.18 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - GENERAL SIGNS

MTL1

PT2

VNL2

MTL1

PT2

VNL2

MTL1

PT3 or PT6

VNL2

MTL1

PT3 or PT6

VNL2

MTL1

PT3 or PT6

VNL2

FOR CONTENT LAYOUT GUIDELINES

SEE SECTION 1 - GRAPHIC STANDARDS

MTL12

PT21

or

WALL

MOUNT

TYPE A TYPE B TYPE C TYPE D

CORNER

RADIUS

.375” TYP.

JYouell

PARK NAME

These rules are provided to ensure this park remains clean, safe, and usable.

INFORMATION

• Field use by permit only. To obtain a permit please call (253) 798-4177.

Alternate parks with open play fields: PARK NAME

• FOR EMERGENCIES CALL 9-1-1

This location is: PARK NAME, Park Address

• To report an unsafe condition: (253) 798-4177

NOT ALLOWED ON THE FIELD

Pets

Metal cleats

Pierce County Parks are tobacco free

Food or beverages including shelled nuts and gum

Discharging of firearms, air or gas weapons and similar devices

Fireworks or explosive devices

Personal aircraft, remote/radio controlled cars/boats/aircraft, drones, rockets, etc.

Golfing, archery or the releasing of any sharp or pointed object

HAVE A GREAT TIME!

Pierce County Code Title 14, Parks and Recreation is enforced through Revised Code of Washington (RCW) 36.68.

Cycles or wheeled devices

Driving stakes into synthetic turf

Alcoholic beverages

2’ - 6”

2’- 6”

ADDENDUM 3 - ATHLETIC FIELDS RULES PANEL

1.2 PARKS & RECREATION - SIGN STANDARDS

09/07/2021

ATHLETIC FIELDS RULES PANEL

This addendum addresses the wording, layout and standards for the panels applied to the following signs:

Athletic Fields Rules Panel

See Section 1 of PARKS & RECREATION - SIGN STANDARDS document for panel materials and finishes.

ATHLETIC FIELDS RULES PANEL MTL1 & GFM1

OR

CHPL1

NOTES

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• Use all stainless steel fasteners.

JYouell Text Box 3.19

JYouell Text Box

SECTION 3 - SIGN TYPES

JYouell

06/01/2025

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1IC

ON

ARROW

2”

1’ - 3”

3’

.5”

.5

SECTION 3 - SIGN TYPES

3.17 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - TRAIL DIRECTIONAL

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

MTL21

MTL21

MTL1

PT3 or PT6

VNL2

MTL1

PT3

VNL2

CORNER

RADIUS

.375” TYP.

JYouell Text Box

PARK SHELTER RULES

JYouell Rectangle

JYouell Snapshot

JYouell Rectangle

JYouell Text Box 06/01/2025

JYouell Text Box 3.20

JYouell Callout

MTL1

JYouell

1/4" HOLE FOR SECURING SIGN TO SHELTER POST. (4) TYPICAL.

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1IC

ON

ARROW

2”

1’ - 3”

3’

.5”

.5

SECTION 3 - SIGN TYPES

3.17 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - TRAIL DIRECTIONAL

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

MTL21

MTL21

MTL1

PT3 or PT6

VNL2

MTL1

PT3

VNL2

CORNER

RADIUS

.375” TYP.

JYouell Rectangle

JYouell Text Box

PROJECT IDENTIFICATION

JYouell Text Box 06/01/2025

JYouell Snapshot

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Text Box 3'-0"

JYouell Text Box 4'-0"

JYouell Rectangle

JYouell Text Box 3.21

JYouell Callout

MTL1

Pierce County Sign Code.

• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.

• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.

• Use all stainless steel fasteners.

• See “PREFERRED MOUNTING BY SIGN

TYPE” in Section 2 - Materials & Finishes.

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 1ARROW

IC

ON

LINE 2 OPT.

LINE 1IC

ON

ARROW

2”

1’ - 3”

3’

.5”

.5

SECTION 3 - SIGN TYPES

3.17 PARKS & RECREATION - SIGN STANDARDS

Original: 02/23/2017 Updated: 09/07/2021

PEDESTRIAN SCALE - TRAIL DIRECTIONAL

FRONT ELEVATION

Scale: 1/2” = 1’-0”

PLAN VIEW

Scale: 1/2” = 1’-0”

SIDE ELEVATION

Scale: 1/2” = 1’-0”

MTL21

MTL21

MTL1

PT3 or PT6

VNL2

MTL1

PT3

VNL2

CORNER

RADIUS

.375” TYP.

JYouell Rectangle

JYouell Text Box

PLANT IDENTIFICATION

JYouell Rectangle

JYouell Snapshot

JYouell Image

JYouell Text Box

PLANT IDENTIFICATION - LARGE

JYouell Text Box

PLANT IDENTIFICATION - SMALL

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Text Box 8"

JYouell Text Box 11"

JYouell Line

JYouell Line

JYouell Callout

MTL1

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Line

JYouell Text Box 7"

JYouell Text Box 5"

JYouell Callout

MTL1

JYouell

3.22

PARKS & RECREATION - SIGN STANDARDS

ADDENDUM 1 Park & Playground Rules Panels

06/13/2017

JYouell

Sign Footing Details

ADDENDUM 2 - SIGN FOUNDATIONS 07/23/2020

Pierce County PARKS & RECREATION - SIGN STANDARDS 1.1

SIGN STANDARDS – STRUCTURAL DESIGN CRITERIA

Design Codes and Standards

Codes and Standards: Structural design and construction shall be in accordance with the applicable sections of the following codes and standards as adopted and amended by the local building authority: International Building Code, 2015 Edition.

Structural Design Criteria:

Live Load Criteria:

Roof (Min Blanket Snow): 25 psf

Wind Load Criteria:

Ultimate Wind Speed: 110 mph

Risk Category: II

Wind Exposure: C

Topographic Factor: 1.0

Minimum Design Pressure: 35 psf (signs 16ft or less)

33 psf (signs 12ft or less)

30 psf (signs 8ft or less)

Seismic Criteria:

Risk Category: II

Seismic Importance Factor: 1.0

Ss = 1.25 S1 = 0.45

Sds = 0.82 Sd1 = 0.467

Site Class: D (assumed)

Soil Design Criteria (Per IBC Table 1806.2):

Soil Bearing Capacity: 1,500 psf, allow 33% increase for loads from wind or seismic origin.

Lateral Bearing Pressure: 266 psf/ft (including 1/3 allowable stress increase)

Material Requirements

Concrete Strength (f’c): 2,500 psi minimum at 28 days

Reinforcing Requirements: ASTM A615 Grade 60

Anchor Bolts: ASTM F1554 Fy = 36 ksi

Adhesive / Epoxy: shall have a current ICC report for cracked concrete in high seismic applications.

All anchor bolts shall be hot-dipped galvanized.

JYouell

ADDENDUM 1 - SIGN FOUNDATIONS

Pierce County PARKS & RECREATION - SIGN STANDARDS 1.2

VEHICULAR SCALE – PARK ENTRY

Pierce County PARKS & RECREATION - SIGN STANDARDS 1.3

VEHICULAR SCALE – DIRECTIONAL

Pierce County PARKS & RECREATION - SIGN STANDARDS 1.4

VEHICULAR SCALE – GENERAL SIGN

Pierce County PARKS & RECREATION - SIGN STANDARDS 1.5

PEDESTRIAN SCALE – PARK ENTRY

Pierce County PARKS & RECREATION - SIGN STANDARDS 1.6

PEDESTRIAN SCALE – PARK INFO AND RULES

Pierce County PARKS & RECREATION - SIGN STANDARDS 1.7

PEDESTRIAN SCALE – PLAYGROUND INFO AND RULES

Pierce County PARKS & RECREATION - SIGN STANDARDS 1.8

PEDESTRIAN SCALE – DIRECTIONAL

Pierce County PARKS & RECREATION - SIGN STANDARDS 1.9

POST INSTALLED ANCHOR OPTIONS

File details come from the government source that posted it. Updated .