About this file
The document is a comprehensive Parks & Recreation Sign Standards manual for Pierce County, Washington, detailing comprehensive design guidelines for park signage across vehicular and pedestrian scales. The manual provides detailed specifications for various sign types including park entry, directional, mile markers, park information, playground rules, trail entry, and general signs. The standards cover graphic design elements, material specifications, color usage, symbol libraries, mounting requirements, and foundation details. The document was originally created on 02/23/2017 and has been updated multiple times, with the most recent update noted as 06/01/2025.
The manual specifies precise technical requirements for sign construction, including recommended materials like Corten steel panels, aluminum, specific paint colors (using Pantone 7701, 7741, and 7579), and mounting techniques. It provides detailed structural design criteria including live load, wind load, and seismic considerations, with specific requirements for concrete strength, reinforcing materials, and anchor bolt specifications. The sign standards aim to create a consistent, recognizable visual identity for Pierce County Parks & Recreation, with careful attention to typography (using Helvetica Neue), symbol design, and color usage that ensures readability and aesthetic cohesion across different sign types and park environments.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2025-ITB-063_Parks_On-Call_Signage.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PARKS & RECREATION - SIGN STANDARDS
SECTION 1 Graphic Standards
SECTION 2 Materials & Finishes
SECTION 3 Sign Types
Original: 02/23/2017 Updated: 09/07/2021
JYouell Text Box
ADDENDUM 1
JYouell Line
JYouell Line
JYouell Text Box Sign Footing Details
JYouell Line
JYouell Text Box Updated 06/01/2025
SECTION 1 - GRAPHIC STANDARDS
1.2 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
Left Up/Forward Right
Left & Back Forward & Left Down Right & Back Forward & Right
TYPEFACE FAMILY
The Helvetica family, known for its classic simplicity and readability, has been selected for the sign standards program.
Headings Text: Helvetica Neue 75 Bold
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890?!”$&
Secondary Text: Helvetica Neue 55 Roman
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz 1234567890?!”$&
LETTER-HEIGHTS
Wherever possible, the following minimum letter-heights have been selected for the program:
Vehicular Scale Signs Headings: 4” min. Secondary: 3” min.
Interpretive & Info. Text Signs Headings: 60 pt. min. Secondary: 16 pt. min.
ARROWS
The following arrow styles have been selected for use in the sign standards program.
JYouell
Updated: 06/01/2025
1.3 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
SYMBOLS
The following symbols have been selected for use in the sign standards program. Whenever possible, the symbols should be accompanied by the nomenclature shown on the chart below. See General Layouts this section for more detail on location and placement.
Access Amphitheater Baseball/Softball Basketball Beach BMX
Boat Launch Camping Climbing Wall Community Center Community Garden Concessions
Cycling Disc Golf Dog Leash & Scoop Dog Park First Aid Golf
Hiking Horse Trail Men Parking Picnic Area Picnic Shelter
Playground Restroom/Toilet Skate Park Soccer Swimming Tennis
Women
JYouell
1.4 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
SYMBOLS Contd.
No Alcohol No ATVs No Camping No Cycling No Dogs No Entry
No Firearms No Fires No Fireworks No Food No Golf/Archery No Horses
No Metal Cleats No Parking No Personal Aircraft No Smoking No Stakes No Vehicles
JYouell
1.5 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
GENERAL LAYOUT
The following layouts are a general guide for the scale and relationship between text, arrows and symbols throughout the sign standards program.
COLOR USE
The following general use applies to color throughout the program. Keep in mind the statement “blue means you’re there, green is informational or how to get there.”
Pantone 7701 Use as a general background color for signs that display the users actual point of location: park name, facility name, Pierce County Parks Name and Logo, mile marker, etc. Use as a background with only white lettering/graphics preferred.
Pantone 7741 Use as a background for all specific directional or parks information items: icons, arrows, etc. Use as a background with only white lettering/graphics preferred.
Pantone 7579 Use as a background as secondary directional or parks information items. Use as a background with only white lettering/graphics preferred.
DOG PARK
PLAYGROUND
PARKING
X X
X .5
X .5
X .5
X .5
X 1.25X1.25X .5X.25X.5X
M
AT
C H
S C
A
LE
C
E N
TE
R
INFORMATION HIERARCHY: List destinations with closest distance to sign first, next closest second, etc.
JYouell
SECTION 2 - MATERIALS & FINISHES
2.1 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PAINT
Code Swatch Type Brand Specification Finish Notes
PT1 Paint Matthews Paint MP 13912 Soda Can Blue
Satin + UV & Graffiti Resistance Clear Coat
Pierce County Logo Blue Pantone 7461
PT2 Paint Matthews Paint MP 12106 Fordson Blue
Satin + UV & Graffiti Resistance Clear Coat Pantone 7701
PT3 Paint Matthews Paint MP 14748 Tucuman Parrot Green
Satin + UV & Graffiti Resistance Clear Coat Pantone 7741
PT4 Paint Matthews Paint MP 32071 White Wonder
Satin + UV & Graffiti Resistance Clear Coat
PT5 Paint Matthews Paint MP 07102 Deep River
Satin + UV & Graffiti Resistance Clear Coat
PT6 Paint Matthews Paint MP 10429 Orange Nature
Satin + UV & Graffiti Resistance Clear Coat Pantone 7579
PT21 Powder Coat Black Satin w/ Graffiti Resistant Properties
PT22 Powder Coat Match to: RAL 5009 Azurblau
Satin w/ Graffiti Resistant Properties
PT23 Powder Coat Match to: RAL 6010 Grasgrün
Satin w/ Graffiti Resistant Properties
PT24 Powder Coat Match to: RAL 2010 Signalorange
Satin w/ Graffiti Resistant Properties
VINYL & GRAPHIC FILM
Code Swatch Type Brand Specification Finish Notes
VNL1 Vinyl 3M Engineer Grade Prismatic Reflective Sheeting 3430 White
Reflective
VNL2 Vinyl 3M 7725-20 Matte White Matte
GFM1 N/A Graphic Film 3M Controltac Graphic Film IJ180-10 Luster with Overlaminate
LAMINATE
Code Swatch Type Brand Specification Finish Notes
CHPL1 N/A
Custom High Pressure Laminate
.048” Thickness Ice + Seal Edges to Prevent Water Damage
CHPL2 N/A
Custom High Pressure Laminate
.5” thickness (Self Supporting)
Ice + Seal Edges to Prevent Water Damage
Drilled and threaded at back for mechanical attachment hardware
JYouell
2.2 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
METAL
Code Swatch Type Brand Specification Finish Notes
MTL1 N/A Aluminum Panel 1/8” thick
MTL2 N/A Corten Steel Panel 1/8” thick Pre-Patina Preferred
Where Available
MTL3 N/A Corten Steel Panel 1/2” thick Pre-Patina Preferred
Where Available
MTL10 N/A Square Metal Post 6” x 6” Powder Coated Welded Caps
MTL11 N/A Square Metal Post 4” x 4” Powder Coated Welded Caps
MTL12 N/A Square Metal Post 2” x 2” Powder Coated Welded Caps
MTL20 N/A Corten Angle 4” x 3”; 1/4” thick Pre-Patina Preferred Where Available
Grind Down/Round All Exposed Edges
MTL21 N/A Corten Tube 2” x 2”; 1/8” thick Pre-Patina Preferred Where Available
Grind Down/Round All Exposed Edges
JYouell Text Box Updated: 06/01/2025
JYouell Image
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell
First Surface/Direct Print;
2.3 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PREFERRED MOUNTING BY SIGN TYPE
Sign Type Surface Mount to Cast-in-Place Footing(s)
Embedded Other
VEHICULAR SCALE SIGNS
Park Entry X Directional X Mile Marker X General Signs X X
PEDESTRIAN SCALE SIGNS
Park Entry X Park Info. & Rules X Playground Info. & Rules X Directional X Mile Marker X Interpretive X X Map X X Trail Entry - Large X Trail Entry - Small X X Trail Directional X X General Signs X X
JYouell
PIERCE COUNTY
PARKS & RECREATION
FIRST LINE
SECOND LINE
PIERCE COUNTY
PARKS & RECREATION
FIRST LINE
SECOND LINE
MERIDIAN
HABITAT PARK
THIRD LINE SPACE
PIERCE COUNTY
PARKS & RECREATION
FIRST LINE
FIRST LINE OPT.
SECOND LINE
PIERCE COUNTY
PARKS & RECREATION
FIRST LINE
FIRST LINE OPT.
SECOND LINE
FI
R S
T L
IN
E
30” x 54”
INFORMATIONAL
PANEL
PIERCE COUNTY
PARKS & RECREATION
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1ARROW
IC
ON
LINE 1 OPT.
ARROW
IC
ON
OPTIONAL
12” x 21”
MAP OR
INFO. PANEL
OPTIONAL
12” x 21”
MAP OR
INFO. PANEL
LINE 1ARROW
LINE 1ARROW
LINE 1ARROW
LINE 1ARROW
T R
IL
N
E MILE
T R
IL
N
E
MILE
27” x 51”
INFORMATIONAL
PANEL
PIERCE COUNTY
PARKS & RECREATION
MILE
MILE
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1IC
ON
ARROW
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1ARROW
IC
ON
LINE 1 OPT.
ARROW
IC
ON
LINE 1ARROW
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
PIERCE COUNTY
PARKS & RECREATION
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
PARK NAME
SECOND LINE
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADER TEXT
HEADER TEXT HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
PIERCE COUNTY
PARKS & RECREATION
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
PARK NAME
SECOND LINE
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADER TEXT
HEADER TEXT HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
ARTWORK PANEL
15” x 48”
INFO.
PANEL
SECTION 3 - SIGN TYPES
3.1 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PARK ENTRY
PARK
INFO. & RULES
TRAIL ENTRY -
LARGE
TRAIL ENTRY -
SMALL
PARK ENTRY PLAYGROUND
INFO & RULES
DIRECTIONAL
TRAIL
DIRECTIONAL
DIRECTIONAL
INTERPRETIVE MAP
MILE
MARKER
GENERAL SIGNS
GENERAL
SIGNS
PEDESTRIAN SCALE SIGNS
VEHICULAR SCALE SIGNS
MILE
MARKER
ARTWORK PANEL
JYouell
NOTES
• All signs in public ROW must conform with
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
MERIDIAN
HABITAT PARK
THIRD LINE SPACE
PIERCE COUNTY
PARKS & RECREATION
FIRST LINE
FIRST LINE OPT.
SECOND LINE
PIERCE COUNTY
PARKS & RECREATION
FIRST LINE
FIRST LINE OPT.
SECOND LINE
8’
- 0
12”6’- 9” STREET
2.5” 8”
6’- 0”
1’- 3” 5’- 4”
1.84”
2.
5”
5” 8”
2.
5”
5” 2.
5” 5”
2.
5”
5” 3”
3” 8”
1.5 ”1
.5
4”
3.5” 3.5”
FIRST LINE OPTION:
Start first line here ONLY if three (3) lines are needed
STREET
SECTION 3 - SIGN TYPES
3.2 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
VNL1
MTL2
MTL2
FABRICATED BOX
“PEAK ELEMENT”
FABRICATED
BOX ELEMENT
SYMBOL
SQUARES
FABRICATED
BOX ELEMENT
FABRICATED BOX
“PEAK ELEMENT”
MTL1
PT2
MTL1
PT2
MTL1
PT3
VNL1
CONCRETE BASE IN
APPROPRIATE FOOTING.
NOTE: FABRICATED BOX
ELEMENTS TO BE SURFACE
MOUNTED TO CONCRETE
BASE, NOT EMBEDDED.
GUTTER TO
CHANNEL BLEED
FROM MTL2
GUTTER TO
CHANNEL BLEED
FROM MTL2;
CREATE SLIGHT
SLOPE AT
HORIZONTAL
SECTION TO
PROMOTE
DRAINAGE
VEHICULAR SCALE - PARK ENTRY
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1ARROW
IC
ON
LINE 1 OPT.
ARROW
IC
ON
1’ - 3”
8”
2’- 9”
STREET
6”6”
SECTION 3 - SIGN TYPES
3.3 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
VEHICULAR SCALE - DIRECTIONAL
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
MTL10
PT21
MTL1
PT3
MTL1
PT2
MTL1
PT3
MTL10
PT21
VNL1
MTL1
PT2
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1ARROW
IC
ON
LINE 1 OPT.
ARROW
IC
ON
LINE 1ARROW
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
1’ - 3”
8”
2’- 9”
STREET
1’ - 3” 6”
STREET
6”
SECTION 3 - SIGN TYPES
3.4 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
VEHICULAR SCALE - DIRECTIONAL - INTERSECTION OPTION
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
MTL1
PT2
MTL1
PT3
MTL1
PT2
MTL1
PT3
MTL10
PT21
VNL1
MTL10
PT21
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
MILE
4” 3”
2’
9” 1”
4”
6”1”
SECTION 3 - SIGN TYPES
3.5 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
VEHICULAR SCALE - MILE MARKER
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
MTL20
MTL1
PT2
VNL1
MTL1
PT2
VNL1
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
PIERCE COUNTY
PARKS & RECREATION
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
PARK NAME
SECOND LINE
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADER TEXT
HEADER TEXT HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
3”
4” 3”
4” 3”
3”
4” 3”
4’ - 8” 4’ - 8”
3’ - 0”
1”
D
IM
E
N S
IO
N
V A
R
IE
S B
A S
E D
O N
C O
N
TE
N T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N L
O C
AT
IO
N
C O
N
TE
N T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N C
O N
TE
N
T D
IM
E
N S
IO
N
V A
R
IE
S B
A S
E D
O N
L O
C
AT
IO
N
C
O N
TE
N
T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N C
O N
TE
N
T D
IM
E
N S
IO
N
V A
R
IE
S B
A S
E D
O N
L O
C
AT
IO
N
C
O N
TE
N
T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N C
O N
TE
N
T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N C
O N
TE
N
T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N L
O C
AT
IO
N
C O
N
TE
N T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N L
O C
AT
IO
N
C O
N
TE
N T
6”
HEADER TEXT
HEADER TEXT
FOR CONTENT LAYOUT GUIDELINES
SEE SECTION 1 - GRAPHIC STANDARDS
SECTION 3 - SIGN TYPES
3.6 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
VEHICULAR SCALE - GENERAL SIGNS
MTL1
PT2
VNL1
MTL12
PT21
or
WALL
MOUNT
TYPE A TYPE B TYPE C
CORNER
RADIUS
.375” TYP.
MTL1
PT3 or PT6
VNL1
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
PIERCE COUNTY
PARKS & RECREATION
FIRST LINE
SECOND LINE
PIERCE COUNTY
PARKS & RECREATION
FIRST LINE
SECOND LINE
6’
3”
6”5’- 0” STREET
2” 6”
4’ - 6”
1’- 3” 4’- 0”
1.38”
2” 2”
2” 6”
4” 4”
4” 4”
2” 2.
2.
6”
1.1
1.1
.5”
2.5” 2.5”
STREET
FIRST LINE OPTION:
Start first line here ONLY if three (3) lines are needed
SECTION 3 - SIGN TYPES
3.7 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - PARK ENTRY
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
VNL1
MTL3
MTL3
FABRICATED
BOX ELEMENT
FABRICATED
BOX ELEMENT
MTL1
PT2
MTL1
PT2
MTL10
PT21
MTL1
PT3
VNL1
GUTTER TO
CHANNEL BLEED
FROM MTL3
GUTTER TO
CHANNEL BLEED
FROM MTL2;
CREATE SLIGHT
SLOPE AT
HORIZONTAL
SECTION TO
PROMOTE
DRAINAGE
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
FI
R
S T
L
IN
E
30” x 54”
INFORMATIONAL
PANEL
PIERCE COUNTY
PARKS & RECREATION
7’
6”1’- 4”
2’- 0”
2”2”
2” 2”
M in
R ig ht
J us tifi ed
T ex t)
4” 2” 2” 2”4”
6”
1’- 0” 5’- 6”
3’- 10”
SECTION 3 - SIGN TYPES
3.8 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - PARK INFO. & RULES
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
EXPANSION OPTION
Scale = 1/4” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
VNL2
GFM1
OR
CHPL1
MTL10
PT 21
IN APPROPRIATE
FOOTINGS
MTL3
ROUTED
LETTERING
TO EXPOSE
MTL3 BEHIND
MTL3 MTL1
PT5
MTL1
PT5
MTL1
PT2
3/4” STANDOFF1/4” STANDOFF
MTL1
PT2
FI
R
S T
L
IN
E
30” x 54”
RULES & INFO.
SIGN PANEL
PIERCE COUNTY
PARKS & RECREATION
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
15” x 48”
INFO.
PANEL
7’
” 5’
4”9”
1’- 3”
1.5”
1.5”
1’- 6”
1’
5”
SECTION 3 - SIGN TYPES
3.9 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - PLAYGROUND INFO. & RULES
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
VNL2
GFM1
OR
CHPL1
MTL11
PT21
IN APPROPRIATE
FOOTING
MTL3
MTL3
MTL11
PT21
MTL1
PT5
1/4” STANDOFFS
MTL1
PT2
CORNER
RADIUS
.375” TYP.
CORNER
RADIUS 3”
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1ARROW
IC
ON
LINE 1 OPT.
ARROW
IC
ON
OPTIONAL
12” x 21”
MAP OR
INFO. PANEL
6’
1’
1”
1’ - 0” 4”
4” 7”
2’- 0”
1’- 2”
PATH
9’
9”
6”
SECTION 3 - SIGN TYPES
3.10 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - DIRECTIONAL
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
VNL2
MTL1
PT3
MTL1
PT2
GFM1
OR
CHPL1
MTL11
PT21
IN APPROPRIATE
FOOTING
MTL11
PT21
MTL1
PT3
MTL1
PT2
MTL1
PT3
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1ARROW
IC
ON
LINE 1 OPT.
ARROW
IC
ON
OPTIONAL
12” x 21”
MAP OR
INFO. PANEL
OPTIONAL
12” x 21”
MAP OR
INFO. PANEL
LINE 1ARROW
LINE 1ARROW
LINE 1ARROW
LINE 1ARROW
9’
” 1’
1”
1’ - 0” 1’ - 0”
4”
9”
6”
7” 2’- 0”
PATH
4”
6’
1’- 2”
SECTION 3 - SIGN TYPES
3.11 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - DIRECTIONAL - INTERSECTION OPTION
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
VNL2
MTL1
PT3
MTL1
PT2
GFM1
OR
CHPL1
MTL11
PT21
MTL11
PT21
MTL1
PT3
MTL1
PT3 MTL1
PT2
MTL1
PT3
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
MILE
4”
2’
7” 1”
3”
1” 4”
1” 4”
3”
SECTION 3 - SIGN TYPES
3.12 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - MILE MARKER
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
MTL20
MTL20
MTL1
PT2
VNL2
MTL1
PT3
VNL2
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
ARTWORK PANEL
3’
1”
2’
3”
SECTION 3 - SIGN TYPES
3.13 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - INTERPRETIVE
FRONT ELEVATION
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
PT22
IZONE IMAGING
CLCB3624IN
CLASSIC SIGN FAMILY
BRACKET POST - CANTILEVER
W/ CHPL PANEL
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
ARTWORK PANEL
3’
1”
2’
3”
SECTION 3 - SIGN TYPES
3.14 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - MAP
FRONT ELEVATION
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
PT23
IZONE IMAGING
CLCB3624IN
CLASSIC SIGN FAMILY
BRACKET POST - CANTILEVER
W/ CHPL PANEL
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
27” x 51”
INFORMATIONAL
PANEL
PIERCE COUNTY
PARKS & RECREATION
4”9”
1’- 3”
1.5”
1.5”
2’- 6”
7’
” 5’
1’
5”
SECTION 3 - SIGN TYPES
3.15 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - TRAIL ENTRY - LARGE
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
VNL2
GFM1
OR
CHPL1
MTL3
MTL3
MTL1
PT3
MTL1
PT5MTL11
PT21
MTL11
PT21
1/4” STANDOFF 3/4” STANDOFF
MTL1
PT2
MTL1
PT5
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
T R
IL
N
E MILE
T R
IL
N
E
MILE
4’
1’ - 0”
4” 3”
3’
5”
2”
9”
PATH PATH
SECTION 3 - SIGN TYPES
3.16 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - TRAIL ENTRY - SMALL
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
REAR ELEVATION
Scale: 1/2” = 1’-0”
VNL2
MTL1
PT3
VNL2
MTL3
ROUTED
LETTERING
TO EXPOSE
MTL3
BEHIND
MTL12
PT21
MTL12
PT21
1/4” STANDOFF
MTL1
PT2
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1IC
ON
ARROW
2”
1’ - 3”
3’
.5”
.5
SECTION 3 - SIGN TYPES
3.17 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - TRAIL DIRECTIONAL
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
MTL21
MTL21
MTL1
PT3 or PT6
VNL2
MTL1
PT3
VNL2
CORNER
RADIUS
.375” TYP.
JYouell
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
PIERCE COUNTY
PARKS & RECREATION
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
PARK NAME
SECOND LINE
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADER TEXT
HEADER TEXT HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
HEADINGARROW
IC
ON
Secondary Text Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
HEADING
Secondary Text
Lorem ipsum dolor sit amet, consectetur adipiscing elit.
3”
4” 3”
4” 3”
3”
4” 3”
4’ - 8” 4’ - 8”
3’ - 0”
1”
D
IM
E
N S
IO
N
V A
R
IE
S B
A S
E D
O N
C O
N
TE
N T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N L
O C
AT
IO
N
C O
N
TE
N T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N C
O N
TE
N
T D
IM
E
N S
IO
N
V A
R
IE
S B
A S
E D
O N
L O
C
AT
IO
N
C
O N
TE
N
T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N C
O N
TE
N
T D
IM
E
N S
IO
N
V A
R
IE
S B
A S
E D
O N
L O
C
AT
IO
N
C
O N
TE
N
T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N C
O N
TE
N
T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N C
O N
TE
N
T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N L
O C
AT
IO
N
C O
N
TE
N T
D
IM
E N
S
IO
N V
A R
IE
S
B A
S E
D O
N L
O C
AT
IO
N
C O
N
TE
N T
6”
HEADER TEXT
HEADER TEXT
SECTION 3 - SIGN TYPES
3.18 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - GENERAL SIGNS
MTL1
PT2
VNL2
MTL1
PT2
VNL2
MTL1
PT3 or PT6
VNL2
MTL1
PT3 or PT6
VNL2
MTL1
PT3 or PT6
VNL2
FOR CONTENT LAYOUT GUIDELINES
SEE SECTION 1 - GRAPHIC STANDARDS
MTL12
PT21
or
WALL
MOUNT
TYPE A TYPE B TYPE C TYPE D
CORNER
RADIUS
.375” TYP.
JYouell
PARK NAME
These rules are provided to ensure this park remains clean, safe, and usable.
INFORMATION
• Field use by permit only. To obtain a permit please call (253) 798-4177.
Alternate parks with open play fields: PARK NAME
• FOR EMERGENCIES CALL 9-1-1
This location is: PARK NAME, Park Address
• To report an unsafe condition: (253) 798-4177
NOT ALLOWED ON THE FIELD
Pets
Metal cleats
Pierce County Parks are tobacco free
Food or beverages including shelled nuts and gum
Discharging of firearms, air or gas weapons and similar devices
Fireworks or explosive devices
Personal aircraft, remote/radio controlled cars/boats/aircraft, drones, rockets, etc.
Golfing, archery or the releasing of any sharp or pointed object
HAVE A GREAT TIME!
Pierce County Code Title 14, Parks and Recreation is enforced through Revised Code of Washington (RCW) 36.68.
Cycles or wheeled devices
Driving stakes into synthetic turf
Alcoholic beverages
2’ - 6”
2’- 6”
ADDENDUM 3 - ATHLETIC FIELDS RULES PANEL
1.2 PARKS & RECREATION - SIGN STANDARDS
09/07/2021
ATHLETIC FIELDS RULES PANEL
This addendum addresses the wording, layout and standards for the panels applied to the following signs:
Athletic Fields Rules Panel
See Section 1 of PARKS & RECREATION - SIGN STANDARDS document for panel materials and finishes.
ATHLETIC FIELDS RULES PANEL MTL1 & GFM1
OR
CHPL1
NOTES
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• Use all stainless steel fasteners.
JYouell Text Box 3.19
JYouell Text Box
SECTION 3 - SIGN TYPES
JYouell
06/01/2025
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1IC
ON
ARROW
2”
1’ - 3”
3’
.5”
.5
SECTION 3 - SIGN TYPES
3.17 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - TRAIL DIRECTIONAL
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
MTL21
MTL21
MTL1
PT3 or PT6
VNL2
MTL1
PT3
VNL2
CORNER
RADIUS
.375” TYP.
JYouell Text Box
PARK SHELTER RULES
JYouell Rectangle
JYouell Snapshot
JYouell Rectangle
JYouell Text Box 06/01/2025
JYouell Text Box 3.20
JYouell Callout
MTL1
JYouell
1/4" HOLE FOR SECURING SIGN TO SHELTER POST. (4) TYPICAL.
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1IC
ON
ARROW
2”
1’ - 3”
3’
.5”
.5
SECTION 3 - SIGN TYPES
3.17 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - TRAIL DIRECTIONAL
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
MTL21
MTL21
MTL1
PT3 or PT6
VNL2
MTL1
PT3
VNL2
CORNER
RADIUS
.375” TYP.
JYouell Rectangle
JYouell Text Box
PROJECT IDENTIFICATION
JYouell Text Box 06/01/2025
JYouell Snapshot
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Text Box 3'-0"
JYouell Text Box 4'-0"
JYouell Rectangle
JYouell Text Box 3.21
JYouell Callout
MTL1
Pierce County Sign Code.
• Use of Pierce County Logo and name must conform with current Pierce County Identity and Graphic Standards.
• All materials, methods of fabrication, attachments, footings and structures to conform with building code requirements.
• Use all stainless steel fasteners.
• See “PREFERRED MOUNTING BY SIGN
TYPE” in Section 2 - Materials & Finishes.
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 1ARROW
IC
ON
LINE 2 OPT.
LINE 1IC
ON
ARROW
2”
1’ - 3”
3’
.5”
.5
SECTION 3 - SIGN TYPES
3.17 PARKS & RECREATION - SIGN STANDARDS
Original: 02/23/2017 Updated: 09/07/2021
PEDESTRIAN SCALE - TRAIL DIRECTIONAL
FRONT ELEVATION
Scale: 1/2” = 1’-0”
PLAN VIEW
Scale: 1/2” = 1’-0”
SIDE ELEVATION
Scale: 1/2” = 1’-0”
MTL21
MTL21
MTL1
PT3 or PT6
VNL2
MTL1
PT3
VNL2
CORNER
RADIUS
.375” TYP.
JYouell Rectangle
JYouell Text Box
PLANT IDENTIFICATION
JYouell Rectangle
JYouell Snapshot
JYouell Image
JYouell Text Box
PLANT IDENTIFICATION - LARGE
JYouell Text Box
PLANT IDENTIFICATION - SMALL
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Text Box 8"
JYouell Text Box 11"
JYouell Line
JYouell Line
JYouell Callout
MTL1
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Line
JYouell Text Box 7"
JYouell Text Box 5"
JYouell Callout
MTL1
JYouell
3.22
PARKS & RECREATION - SIGN STANDARDS
ADDENDUM 1 Park & Playground Rules Panels
06/13/2017
JYouell
Sign Footing Details
ADDENDUM 2 - SIGN FOUNDATIONS 07/23/2020
Pierce County PARKS & RECREATION - SIGN STANDARDS 1.1
SIGN STANDARDS – STRUCTURAL DESIGN CRITERIA
Design Codes and Standards
Codes and Standards: Structural design and construction shall be in accordance with the applicable sections of the following codes and standards as adopted and amended by the local building authority: International Building Code, 2015 Edition.
Structural Design Criteria:
Live Load Criteria:
Roof (Min Blanket Snow): 25 psf
Wind Load Criteria:
Ultimate Wind Speed: 110 mph
Risk Category: II
Wind Exposure: C
Topographic Factor: 1.0
Minimum Design Pressure: 35 psf (signs 16ft or less)
33 psf (signs 12ft or less)
30 psf (signs 8ft or less)
Seismic Criteria:
Risk Category: II
Seismic Importance Factor: 1.0
Ss = 1.25 S1 = 0.45
Sds = 0.82 Sd1 = 0.467
Site Class: D (assumed)
Soil Design Criteria (Per IBC Table 1806.2):
Soil Bearing Capacity: 1,500 psf, allow 33% increase for loads from wind or seismic origin.
Lateral Bearing Pressure: 266 psf/ft (including 1/3 allowable stress increase)
Material Requirements
Concrete Strength (f’c): 2,500 psi minimum at 28 days
Reinforcing Requirements: ASTM A615 Grade 60
Anchor Bolts: ASTM F1554 Fy = 36 ksi
Adhesive / Epoxy: shall have a current ICC report for cracked concrete in high seismic applications.
All anchor bolts shall be hot-dipped galvanized.
JYouell
ADDENDUM 1 - SIGN FOUNDATIONS
Pierce County PARKS & RECREATION - SIGN STANDARDS 1.2
VEHICULAR SCALE – PARK ENTRY
Pierce County PARKS & RECREATION - SIGN STANDARDS 1.3
VEHICULAR SCALE – DIRECTIONAL
Pierce County PARKS & RECREATION - SIGN STANDARDS 1.4
VEHICULAR SCALE – GENERAL SIGN
Pierce County PARKS & RECREATION - SIGN STANDARDS 1.5
PEDESTRIAN SCALE – PARK ENTRY
Pierce County PARKS & RECREATION - SIGN STANDARDS 1.6
PEDESTRIAN SCALE – PARK INFO AND RULES
Pierce County PARKS & RECREATION - SIGN STANDARDS 1.7
PEDESTRIAN SCALE – PLAYGROUND INFO AND RULES
Pierce County PARKS & RECREATION - SIGN STANDARDS 1.8
PEDESTRIAN SCALE – DIRECTIONAL
Pierce County PARKS & RECREATION - SIGN STANDARDS 1.9
POST INSTALLED ANCHOR OPTIONS