PACKING TABLES LAYOUT AND SPECS.pdf

PDF 447 KB Posted

Attached to
68th RQS Parachute Packing Tables Federal contract opportunity
Solicitation number
FA487722QU033
Issued by
Department of the Air Force Air Combat Command

View the file

Other files for this federal contract opportunity

Other files attached to 68th RQS Parachute Packing Tables, newest first.
File Type Posted
COMBO_Synopsis_Solicitation - Parachute Packing Tables.pdf PDF
Provisions and Clauses_Parachute Packing Tables_PDF.pdf PDF
PACKING TABELS SALIENT CHARACTERISTICS.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Packing lane #1

50’

38”

Anti-Fatigue walking mat

Packing lane #2

Anti-Fatigue walking mat

40”

24”

13’

Packing lanes lay out

36”

36”

NOTE: not drawn to scale

BO

TTO

M

TO

P

LEFT SIDE PACKING LANE

RIGHT SIDE PACKING LANE

WALL

W

ALL

Packing lane #1

Anti-Fatigue walking mat 50-Feet by 24-inches by 1-inch thick

Legend

NOTE: not drawn to scale

D2 D2 D2 D2

D2 D2 D2 D2

D2 D2 D2 D2

D2 D2 D2 D2

D2 D2

D2 D2D1

D1

D3

D3

EXAMPLE OF PACKING LANE EXPECTATION

D1 =

BOTTOM TABLE. CTK TABLE. HAS 5 SLIDING DRAWERS. SNAG FREE.

MUST HAVE ANCHOR POINT FOR TENSION DEVICES. (400LBS PRESSURE)

TABLE TOP MUST HAVE PADDED TOP WITH CORDURA, LEATHER OR SIMILAR FINISH.

PADDED TOP MUST EXTEND TO 8-FEET MINIMUM. PADDING MAY NEED TO BE ADDED TO A “D2” TABLE TO MEET THIS REQUIREMENT

D2 = CENTER TABLE. HAS CABINET DRAWERS. INSIDE MUST HAVE A STABLE FLOOR FOR UNPACKED PARACHUTES SNAG FREE.

MUST BE STABLE DURING PACK OPERATIONS AND STUDY TO WITHSTAND WEIGHT REQUIREMENTS

TABLE TOP MUST BE 2-INCH BUTCHER BLOCK WITH FINISH AND SNAG FREE. TABLES MUST ALIGN AND LINK TOGETHER

WITH NO SPACES IN BETWEEN.

D3 =

TOP TABLE. CTK TABLE. HAS 5 SLIDING DRAWERS SNAG FREE.

MUST HAVE ANCHOR POINT FOR TENSION DEVICES. (400LBS PRESSURE)

TABLE TOP MUST BE 2-INCH BUTCHER BLOCK WITH FINISH AND SNAG FREE. TABLES MUST ALIGN AND LINK TOGETHER

WITH NO SPACES IN BETWEEN.

BO

TTO

M

TO

P

LEFT SIDE PACKING LANE

RIGHT SIDE PACKING LANE

D1 PACKING TABLE

NOTE: not drawn to scale

D1 =

BOTTOM TABLE. CTK TABLE. HAS 5 SLIDING DRAWERS. SNAG FREE.

MUST HAVE ANCHOR POINT FOR TENSION DEVICES. (400LBS PRESSURE)

TABLE TOP MUST HAVE PADDED TOP WITH CORDURA, LEATHER OR SIMILAR FINISH.

PADDED TOP MUST EXTEND TO 8-FEET MINIMUM. PADDING MAY NEED TO BE ADDED TO A “D2” TABLE TO MEET THIS REQUIREMENT

DRAWER 1. 4-INCH HT

DRAWER 2. 4-INCH HT

DRAWER 3. 4-INCH HT

DRAWER 4. 8-INCH HT

DRAWER 5. 10-INCH HT

EACH DRAWER MUST BE ABLE TO HOLD 80 POUNDS MINIMUM

ANCHOR POINT MUST BE ABLE TO WITHSTAND

400=POUNDS OF PRESSURE

MUST BE CENTERED OF THE PACKING LANE,

NOT THE TABLE ITSELF. IF 2 TABLES ARE USED

FOR THE PACKING LANE, THE ANCHOR POINT

MUST BE ADJUSTED SO IT CAN BE CENTERED

ON THE LANE.

TABLE TOP MUST BE PADDED

MINIMUM 1/2 – INCH PADDING COVERED WITH CORDURA,

LEATHER OR APPROVED LIKE ITEM.

PADDING MUST EXTEND TO 8-FEET AND THE WIDTH OF THE TABLE TOP.

PADDING MUST BE EVEN OR NO MORE THAN 1/2-INCH HIGHER THAN

ADJOINING PACK TABLES.

RED OR BLUE IS THE PREFERRED COLOR FOR THE PADDING COVER

D2 PACKING TABLE

D2 =

CABINET DRAWER

FACE AND HANDLES MUST ALL BE SNAG FREE. RECESSED

HANDLES ARE PREFERRED BUT NOT MANDATORY. AS LONG AS

EACH OPENING HANDLE DOES NOT CREAT A SNAG POINT.

EACH END OF EACH INDIVIDUAL CABINET DO

NOT HAVE TO CONTAIN WALLS. AS LONG AS

THE BOTTOM IS SMOOTH AND AT LEAST 2-

INCHES OFF THE GROUND AND STURDY, THESE

CABINETS DO NOT HAVE TO BE SEPARATED.

EACH TABLE OF SQUARE METER OF TABLE TOP

MUST BE ABLE TO WITHSTAND 200-POUNDS

AND EVERY POINT.

TABLE TOP MUST BE FINISHED BUTCHER BLOCK. SPLINTER PROOF.

EDGES MUST BE ROUNDED ON THE LEFT AND RIGHT SIDE OF THE

PACKING LANE.

EACH PORTION OF THE TOP MUST BE LEVEL THROUGH THE ENTIRE

PORTION WITH NO MORE THAN 1/32-INCH DIFFERENCE BETWEEN

SECTIONS.

ALL PIECES MUST BE ADJOINED AND NOT CAUSE SEPARATION BY MORE

THAN 1/64-INCH DURING PACK OPERATIONS.

CABINET DRAWER

CENTER TABLES. HAVE CABINET DRAWERS. INSIDE MUST HAVE A STABLE FLOOR FOR UNPACKED PARACHUTES SNAG FREE.

MUST BE STABLE DURING PACK OPERATIONS AND STUDY TO WITHSTAND WEIGHT REQUIREMENTS

TABLE TOP MUST BE 2-INCH BUTCHER BLOCK WITH FINISH AND SNAG FREE. TABLES MUST ALIGN AND LINK TOGETHER

WITH NO SPACES IN BETWEEN.

D3 PACKING TABLE

D3 =

DRAWER 1. 4-INCH HT

DRAWER 2. 4-INCH HT

DRAWER 3. 4-INCH HT

DRAWER 4. 8-INCH HT

DRAWER 5. 10-INCH HT

EACH DRAWER MUST BE ABLE TO HOLD 80 POUNDS MINIMUM

ANCHOR POINT MUST BE ABLE TO WITHSTAND

400=POUNDS OF PRESSURE

MUST BE CENTERED OF THE PACKING LANE,

NOT THE TABLE ITSELF. IF 2 TABLES ARE USED

FOR THE PACKING LANE, THE ANCHOR POINT

MUST BE ADJUSTED SO IT CAN BE CENTERED

ON THE LANE. THIS IS SIMILAR TO THE

BOTTOM TABLE BUT IS FOR THE TOP.

TABLE TOP MUST BE FINISHED BUTCHER BLOCK.

SPLINTER PROOF.

EDGES MUST BE ROUNDED ON THE LEFT, RIGHT AND TOP SIDE OF THE PACKING LANE.

EACH PORTION OF THE TOP MUST BE LEVEL THROUGH THE ENTIRE PORTION WITH NO MORE

THAN 1/32-INCH DIFFERENCE BETWEEN SECTIONS.

ALL PIECES MUST BE ADJOINED AND NOT CAUSE SEPARATION BY MORE THAN 1/64-INCH

DURING PACK OPERATIONS.

TOP TABLE. CTK TABLE. HAS 5 SLIDING DRAWERS SNAG FREE.

MUST HAVE ANCHOR POINT FOR TENSION DEVICES. (400LBS PRESSURE)

TABLE TOP MUST BE 2-INCH BUTCHER BLOCK WITH FINISH AND SNAG FREE. TABLES MUST ALIGN AND LINK TOGETHER

WITH NO SPACES IN BETWEEN.

Packing lane

50’

Packing lanes lay out

72”

124”

TO

P

= 5/8-inch wide hole required at these two points. Must support 200-pounds of pressure.

Must have minimum 1-inch wide metallic spacer and be flush with the table top, smooth and free of snag points. Metal spacer must go all the way through so the attachment bolt does not tear into the wood.

Must not be movable. Bottom must be easily accessible to attach a tightening nut when required.

Slide Number 1
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6

File details come from the government source that posted it. Updated .