P810 Structural Drawings Excerpt - Steel Wing Piles.pdf
PDF 823 KB Posted
- Solicitation number
- W912HV-23-Z-0002
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M
Pa
M Pa
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
DE
SI
GN
ED
B Y:
DR
AW
N
BY
SU
BM
IT
TE
D
BY
CH
EC
KE
D
BY
SI
ZE
IS
O A1
IS
SU
E
DA
TE
CO
NT
RA
CT
N O.
SO
LIC
IT
AT
IO
N
NO
SHEET ID
a
FI
LE
B.
F
IS
HE
R
B.
F
IS
HE
R
B.
F
IS
HE
R
S.
S
CH
NE
ID
ER
JU
LY
, 2
W
2H V2
1F
-P
S-001
BLDG P810
IN
TE
RM
ED
IA
TE
D
ES
IG
N
SU
BM
IT
TA
L 0 7/2
5/2
ST
RU
CT
UR
AL
G
EN
ER
AL
N
OT
ES
CODES AND STANDARDS
1. ACI 318-14M, BUILDING CODES REQUIREMENTS FOR STRUCTURAL CONCRETE (2014)
2. AISC 360-16, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (2016)
3. ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES (2016)
4. IBC, 2018 INTERNATIONAL BUILDING CODE (2018)
5. JASS 5, JAPANESE ARCHITECTURAL STANDARD SPECIFICATION FOR REINFORCED CONCRETE
WORK, ARCHITECTURAL INSTITUTE OF JAPAN (2018)
6. JASS 7, JAPANESE ARCHITECTURAL STANDARD SPECIFICATION FOR MASONRY
CONSTRUCTION, ARCHITECTURAL INSTITUTE OF JAPAN (2009)
7. MLIT COMMON BUILDING CONSTRUCTION STANDARD SPECIFICATONS, 2019 (HEISEI 31) WITH
2020 (REIWA 2) AND 2021 (REIWA 3) REVISIONS
8. TMS 605, SPECIFICATION FOR MASONRY STRUCTURES, THE MASONRY SOCIETY (2016)
9. UFC-1-200-01, DoD BUILDING CODE, CHANGE 1, 1 OCTBOER 2020
10. UFC 3-301-01, STRUCTURAL ENGINEERING, 1 OCTOBER 2019, CHANGE 1, 4 FEBRUARY 2022
11. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12 DECEMBER 2018
12. UFC 4-023-03, DESIGN OF BUILDINGS TO RESIST PROGRESSIVE COLLAPSE, CHANGE 3, 1
NOVEMBER 2016
GENERAL
1. CONTRACTOR SHALL BE RESPONSIBLE FOR THE MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES REQUIRED TO PERFORM THIS WORK.
2. THE CONTRACT DOCUMENT REPRESENT THE COMPLETED STRUCTURE AND DO NOT
NECESSARILY INCLUDE THE MEANS OR METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL
PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ENSURE IT IS SAFE AND
STABLE UNTIL COMPLETION. MEASURES INCLUDE, BUT ARE NOT LIMITED TO BRACING AND
SHORING FOR LOADS FROM CONSTRUCTION EQUIPMENT, TEMPORARY STRUCTURES AND
PARTIALLY COMPLETED WORK.
3. THE CONTRACTOR SHALL DESIGN AND INSTALL SHORING TO SUPPORT CONSTRUCTION
(VERTICALLY AND LATERALLY) UNTIL STRUCTURAL COMPONENTS HAVE BEEN CONNECTED AS
SHOWN ON THE STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL SUBMIT SHORING
DRAWINGS AND CALCULATIONS STAMPED AND SIGNED BY LICENSED STUCTURAL ENGINEER.
DRAWINGS SHALL SHOW THE SIZE, LAYOUT, CONNECTIONS, MATERIAL DESIGNATION, METHOD
OF INSTALLATION, AND ACCESSORIES OF SHORING MEMBERS.
4. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS BEFORE COMMENCING ANY
DEMOLITION. THE CONTRACTOR SHALL VERIFY THE EXTENT AND LOCATION OF THE SITE
UTILITIES. LOCATIONS OF EXISTING STRUCTURES, FOUNDATIONS AND UTILITIES KNOWN TO THE
STRUCTURAL ENGINEER ARE INDICATED ON THE DRAWINGS. REPORT ANY DISCREPANCIES OR
ENCOUNTERED OBSTRUCTIONS TO THE CONTRACTING OFFICER.
5. CONTRACTOR-INITIATED CHANGES REQUIRE APPROVAL BY THE CONTRACTING OFFICER AND
SHALL BE SUBMITTED IN WRITING TO THE CONTRACTING OFFICER FOR APPROVAL PRIOR TO
FABRICATION OR CONSTRUCTION.
6. DIMENSIONS AND DETAILS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO FABRICATION
AND CONSTRUCTION. THIS INCLUDES, BUT IS NOT LIMITED TO, COORDINATING WITH THE
CONTRACT DOCUMENTS OF THE SIZE AND LOCATION OF THE OPENINGS THROUGH CONCRETE,
VERIFYING SIZE AND LOCATION OF THE MECHANICAL AND ELECTRICAL OPENINGS WITH THE
RESPECTIVE SUBCONTRACTOR, AS WELL AS COORDINATING INSERTS AND ATTACHMENTS FOR
THE USE OF OTHER TRADES.
7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. TYPICAL DETAILS
AND NOTES SHOWN ON DRAWINGS SHALL APPLY UNLESS NOTED OTHERWISE. TYPICAL DETAILS
MAY NOT NECESSARILY BE INDICATED ON THE PLANS BUT SHALL STILL APPLY AS SHOWN OR
DESCRIBED IN THE DETAILS. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO CHOOSE THE
APPROPRIATE TYPICAL DETAIL FROM THOSE PROVIDED. THE CONTRACTOR SHALL SUBMIT
PROPOSED ALTERNATIVE DETAILS TO THOSE PROVIDED WITH RELATED CALCULATIONS TO THE
CONTRACTING OFFICER FOR APPROVAL PRIOR TO DETAILING OR USE.
8. CONFLICTS OR OMISSIONS WITHIN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE
ATTENTION OF THE CONTRACTING OFFICER PRIOR TO PROCEEDING WITH THE WORK INVOLVED.
9. PENETRATIONS FOR PIPES, DUCTS, CHASES, ETC., ARE NOT PERMITTED IN STRUCTURAL
BEAMS, BRACES, FOUNDATIONS, COLUMNS OR OTHER STRUCTURAL ELEMENTS, UNLESS NOTED
OTHERWISE IN THESE DRAWINGS. THE CONTRACTOR SHALL OBTAIN WRITTEN APPROVAL FROM
THE STRUCTURAL ENGINEER OF RECORD BEFORE CUTTING, PENETRATING, OR OTHERWISE
MODIFYING STRUCTURAL MEMBERS IN ORDER TO ACCOMMODATE PIPES, DUCTS, CHASES, ETC.
10. DETAILS OF CONCRETE ELEMENTS MANY NOT SHOW ALL REINFORCEMENT THAT OCCURS
WITHIN THE SECTION SHOWN, WHEN NECESSARY FOR CLARITY OR TO HIGHLIGHT SPECIFIC
REINFORCEMENT REQUIREMENTS. WHERE REINFORCEMENT IS NOT SHOWN, IT DOES NOT
ALLEVIATE THE CONTRACTOR FROM FURNISHING THE REINFORCEMENT REQUIRED BY OTHER
DETAILS OR NOTES PER THESE DRAWINGS.
FOUNDATIONS
1. FOUNDATION DESIGN IS BASED ON THE FINAL PDA SUBMITTAL GEOTECHNICAL REPORT BY OYO
CORPORATION, DATED 20 JUNE 2022, OYO JOB NUMBER 212001.
2. SPECIAL INSPECTION SHALL BE PERFORMED DURING SITE EXCAVATION TO CONFIRM THAT
EXISTING CONDITIONS COMPLY WITH CONDITIONS IN THE GEOTECHNICAL REPORT.
3. DESIGN SOIL PROPERTIES:
4. DEGREE OF COMPACTION, AS SPECIFIED IN THESE DOCUMENTS BY PERCENT RELATIVE DENSITY, SHALL BE PER ASTM D1557 OR JIS A1210. UNLESS NOTED OTHERWISE, STRUCTURAL FILL AND
COMPETENT NATIVE SOIL SHALL BE COMPACTED TO 95% RELATIVE DENSITY.
5. EXCAVATIONS SHALL BE KEPT FREE OF LOOSE MATERIAL AND STANDING WATER. MAINTAIN
SUBGRADE AND FILL MOISTURE CONTENT UNTIL FOUNDATION ARE PLACED. MAINTAIN POSITIVE
DRAINAGE AWAY FROM THE SITE DURING CONSTRUCTION TO ENSURE SURFACE RUNOFF AWAY
FROM THE STRUCTURES AND TO PREVENT PONDING OF SURFACE RUNOFF NEAR THE
STRUCTURE. KEEP OPEN EXCAVATIONS AROUND THE STRUCTURE DRY. PUMP WATER OUT OF
EXCAVATIONS IF FLOODING OCCURS PRIOR TO BACKFILL AND COMPACTION. EXCESS SOILS
FROM EXCAVATIONS MAY NOT BE REUSED AS BACKFILL UNDERNEATH STRUCTURES, AND
THEREFORE WILL NEED TO BE DISPOSED/WASTED. OVEREXCAVATION OF IN-SITU ELASTIC SILTS
AND CONSEQUENT REPLACEMENT WITH ENGINEERED GRANULAR FILL OR LEAN CONCRETE MAY
REQUIRE TEMPORARY SHORING SYSTEMS IF SLOWED EXCAVATIONS ARE NOT FEASIBLE.
6. DO NOT BACKFILL AGAINST STRUCTURAL CONCRETE ELEMENTS UNTIL CONCRETE HAS REACHED
A MINIMUM OF 75% OF THE SPECIFIED 28-DAY MINIMUM COMPRESSION STRENGTH.
7. PIPES AND CONDUITS RUNNING THROUGH SLABS ON GRADE AND SUBGRADE WALLS SHALL BE
PROTECTED WITH 13 mm EXPANSION MATERIAL.
8. FORM SIDES OF FOOTINGS, TIE BEAMS, PILE CAPS, ETC., TO BE STRAIGHT, PLUMB AND IN
ACCORDANCE WITH THE SPECIFIED DIMENSIONS. EARTH FORMS ARE PROHIBITED.
9. SLAB-ON-GRADE BASE COURSE SHALL BE PREPARED AS ILLUSTRATED PER SHEET S-101A AND S-101B. CONCRETE SLABS MUST BE UNDERLAIN WITH 300 mm OF IMPORTED GRANULAR FILL
COMPACTED TO A MINIMUM OF 95% MAXIMUM DRY DENSITY BASED ON JIS A 1210 OR ASTM
D-1557. THE TOP 150 mm OF SUBGRADE SOILS OR FILL UNDERNEATH THE IMPORTED GRANULAR FILL YALER MUST BE COMPACTED TO A MINIMUM OF 95% IN THE CASE OF GRANULAR SOILS OR
90% IN THE CASE OF COHESIVE SOILS.
10. PROVIDE 0.38 mm VAPOR BARRIER AT THE TOP OF THE BASE COURSE BELOW SLABS-ON-GRADE.
OVERLAP SHEET EDGES BY 300 mm MINIMUM.
11. STEEL WING PILE PROPERTIES (PER PILE):
12. PILES MUST EXTEND TO THE ACCEPTABLE BEARING LAYER, APPROXIMATELY 13 m BELOW
EXISTING GRADE. BEARING LAYER IS ASSUMED TO HAVE AN AVERAGE N-VALUE NAVG ≥ 40.
13. CENTER TO CENTER DISTANCE BETWEEN PILES IN A GROUP MUST BE SPACED A DISTANCE OF 1-
WING DIAMETER PLUS ONE PILE DIAMETER.
STRUCTURAL CONCRETE
1. CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 301, SPECIFICATION FOR STRUCTURAL
CONCRETE.
2. DESIGN MIXES FOR THE FOLLOWING CLASSES OF CONCRETE SHALL BE PROPORTIONED TO PROVIDE THE FOLLOWING MININIMUM COMPRESSIVE STRENGTH AT 28-DAYS, f'c (MPa). THE MIX MUST INCLUDE THE STRENGTH CORRECTION FACTOR AND TEMPERATURE CORRECTION FACTOR AS REQUIRED PER JASS 5 AND MLIT "PROPORTIONING" TO ENSURE THE AS-CAST CONCRETE STRENGTH MEETS OR EXCEEDS THE SPECIFIED MINIMUM COMPRESSION STRENGTH AT 28-DAYS. REF. JASS 5, SEC. 5 OR MLIT STD SPEC. SEC.
6.3.2.
3. STEEL REINFORCEMENT SHALL CONFORM TO THE FOLLOWING STANDARDS AND SPECIFIED STRENGTH:
4. TYPICAL DETAILS FOR REINFORCEMENT SUCH AS HOOKS, BEND DIAMETERS, ETC. SHALL BE IN ACCORDANCE WITH ACI SP-66, "ACI DETAILING MANUAL". REFER TO DETAIL SHEETS FOR ADDITIONAL
INFORMATION.
REINFORCEMENT
DEFORMED BARS
• D16 AND SMALLER
DEFORMED BARS (WELDABLE)
• D19 THROUGH D25
• D29 AND LARGER
5. REINFORCEMENT MARKED "CONT" (CONTINUOUS) SHALL BE SPLICED BY LAPPING OR MECHANICAL CONNECTORS OR GAS PRESSURE WELDING (CONFORMING WITH JASS 5). BAR SIZES D25 AND LARGER
MUST BE SPLICED WITH MECHANICAL CONNECTORS OR GAS PRESSURE WELDING.
LAP LENGTH NOTES:
A. SEE DEVELOPMENT AND LAP SPLICE LENGTH SCHEDULE FOR REINFORCED CONCRETE.
B. MECHANICAL CONNECTORS SHALL HAVE A MINIMUM CAPACITY OF 1.25x THE YIELD STRENGTH OF
THE BAR.
C. IN MEMBERS DESIGNATED AS PART OF THE SEISMIC-FORCE-RESISTING-SYSTEM, MECHANICAL CONNECTORS SHALL HAVE A MINIMUM CAPACITY EQUAL TO THE TENSILE STRENGTH OF THE BAR.
6. MECHANICAL REBAR ANCHORS (TERMINATORS) SHALL BE THREADED DEVICES WITH A CAPACITY
GREATER THAN THE YIELD STRENGTH OF THE BAR.
7. REFER TO THE ARCHITECTURAL, ELECTRICAL, MECHANICAL AND STRUCTURAL DRAWINGS FOR SURFACE FEATURES AND INSERTS, TO BE CAST IN CONCRETE AND FOR LOCATIONS OF PENETRATIONS
FOR PIPES, DUCTS, CONDUITS, ETC.
8. CONCRETE COVER FOR REINFORCEMENT STEEL SHALL BE AS FOLLOWS PER ACI 318 TABLE 20.6.1.3.1, UNLESS NOTED OTHERWISE:
CONCRETE EXPOSURE
CAST AGAINST AND
PERMANENTLY IN
CONTACT WITH GROUND
EXPOSED TO WEATHER
OR IN CONTACT WITH
GROUND
NOT EXPOSED TO
WEATHER OR IN
CONTACT WITH GROUND
MEMBER
ALL
ALL
SLABS, JOISTS
AND WALLS
BEAMS, COLUMNS,
PEDESTALS, AND
TENSION TIES
REINFORCEMENT
ALL
D19 THROUGH D51 BARS
D16 BAR AND SMALLER
D38 AND LARGER
D35 BAR AND SMALLER
PRIMARY REINF,
STIRRUPS, TIES,
SPIRALS AND HOOPS
SPECIFIED
COVER (mm)
MIN. YIELD STRENGTH
Fy (MPa)
NON-SHRINK GROUT
1. NON-SHRINK GROUT SHALL BE CEMENTITIOUS HIGH PRECISION, NATURAL AGGREGATE, NON-
METALLIC, NON-STAINING, NON-SHRINKABLE GROUP CONFORMING TO ASTM C1107 AND CRD-C
621, CORPS OF ENGINEERS "SPECIFICATION FOR NON-SHRINK GROUT." GROUT SHALL HAVE A
SPECIFIED MINIMUM COMPRESSIVE STRENGTH SHOW IN THE FOLLOWING TABLE.
2. DRY PACKING OF GROUT OF BASE PLATES SHALL NOT BE PERMITTED.
DESIGN LOADING
1. THE STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH UFC 3-301-01, THE
INTERNATIONAL BUILDING CODE, IBC, AND THE ASCE 7, AS REFERENCED IN THE "CODES
AND STANDARDS" SECTION OF THIS SHEET.
2. DEAD LOADING
WEIGHT OF MATERIALS OF CONSTRUCTION AND PERMANENTLY INSTALLED EQUIPMENT.
3. LIVE LOADING
REFER TO LIVE LOAD MAPS ON SHEET S-010.
4. ROOF LIVE LOADING
UNIFORM ROOF LIVE LOAD
SPECIFICATION
JIS G 3112 SD295A
JIS G 3112 SD345
JIS G 3112 SD390
9. REINFORCING BARS SHALL BE SECURELY TIED AND IN POSITION PRIOR TO THE PLACEMENT OF
CONCRETE. REINFORCEMENT, INCLUDING DOWELS SHALL NOT BE "WET-SET".
10. FIELD BENDING OF REBAR THAT HAS BEEN PARTIALLY EMBEDDED IN A PREVIOUSLY CAST MEMBER IS
PROHIBITED.
11. A SINGLE FIELD BEND PER LOCATIONS UP TO A MAXIMUM OF 90° ARE PERMITTED FOR REINFORCEMENT THAT HAS NOT PARTIALLY EMBEDDED IN CONCRETE. BARS LARGER THAN D19 SHALL NOT BE FIELD
BENT. HEATING THE REBAR WITH A TORCH, ETC., IS PROHIBITED.
12. PROVIDE VERTICAL DOWELS FROM THE FOUNDATION TO MATCH THE SIZE AND SPACING OF THE WALL OR COLUMN REINFORCEMENT. AT A MINIMUM, DOWELS SHALL BE SIDED TO PROVIDE FULL TENSION
DEVELOPMENT LENGTH ON BOTH SIDES OF THE COLD-JOINT.
5. SNOW LOADING
GROUND SNOW LOAD
FROST PENETRATION DEPTH
6. WIND LOADING
ULTIMATE DESIGN WIND SPEED (3-SEC GUST)
RISK CATEGORY
WIND EXPOSURE CATEGORY
ENCLOSURE CLASSIFICATION
INTERNAL PRESSURE COEFFICIENT
COMPONENTS AND CLADDING PRESSURES
7. RAIN LOAD
1-HR INTENSITY (NAHA)
10-MIN INTENSITY (NAHA)
NOT APPLICABLE
NOT APPLICABLE
283 kph (78.6 m/s)
II
C
ENCLOSED
GCpi = ±0.18
SEE SHEET S-011
110.5 mm
29.5 mm
SOIL PROPERTY
ALLOWABLE BEARING PRESSURE
• STATIC LOAD CASES
• TRANSIENT LOAD CASES
MODULUS OF SUBGRADE REACTION
COEFFICIENT OF FRICTION
LATERAL EARTH PRESSURE
• AT-REST CONDITIONS
• ACTIVE CONDITIONS
• PASSIVE CONDITIONS
REPORTED VALUE
100 kN/m2
133 kN/m2
27 MN/m3
0.40
9 kN/m3
6 kN/m3 kN/m3
MINIMUM COMPRESSIVE STRENGTH
AT 5-DAYS (MPa)
STRUCTURAL CONCRETE (CONTINUED)
WATERSTOPS
1. PROVIDE NONMETALIC WATER STOPS FOR USE WITH CONCRETE JOINTS AT THE BASE OF
THE ELEVATOR PIT WALL.
2. PVC WATERSTOPS SHALL MEET CORPS OF ENGINEERS SPECIFICATION CRD-C 572-74 OR
JIS K 6773.
3. FOLLOW APPROVED WATERSTOP MANUFACTURER RECOMMENDATIONS.
4. LOCATE WATERSTOPS CENTERED AT JOINT, COORDINATE LOCATION TO AVOID CONTACT
WITH REINFORCEMENT.
SUBMITTALS
1. BY SUBMITTING THE SHOP DRAWINGS, THE CONTRACTOR HAS DETERMINED AND
VERIFIED MATERIALS, FIELD MEASUREMENTS, AND RELATED FIELD CONSTRUCTION
CRITERIA (MEANS, METHODS, TECHNIQUES, SEQUENCES, OPERATIONS OF
CONSTRUCTION, SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO), AND
THAT THE CONTRACTOR HAS CHECKED AND COORDINATED THE INFORMATION
CONTAINED WITHIN THE SUBMITTAL WITH THE REQUIREMENTS OF THE WORK AND THE
CONTRACT DOCUMENTS.
2. THE CONTRACTOR SHALL REVIEW ALL SUBCONTRACTOR SUBMITTALS PRIOR TO
SUBMITTING TO THE GOVERNMENT CONTRACTING OFFICER.
3. REVIEW BY THE ENGINEER OF RECORD SHALL NOT RELIEVE THE CONTRACTOR FROM
FULL RESPONSIBILITY FOR THE ACCURACY OF DIMENSIONS AND DETAILS. SUCH REVIEW
SHALL NOT CONSTITUTE ACCEPTANCE BY THE ENGINEER OF RECORD FOR THE
CORRECTNESS OR ADEQUACY OF SUCH SUBMITTALS, NOR A WARRANTY THAT THE
SUBMITTALS SATISFY THE REQUIREMENTS OF THE CONTRACT.
4. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING SIZE, WEIGHT,
ANCHORAGE, LOCATIONS OF EQUIPMENT NOT INDICATED ON THESE STRUCTURAL
DRAWINGS PRIOR TO ORDERING TO BE REVIEWED BY THE GOVERNMENT AND
STRUCTURAL ENGINEER OF RECORD TO DETERMINED THE ADEQUACY OF THE
STRUCTURE TO SUPPORT SUCH LOADING.
5. CONTRACTOR DESIGNED ELEMENTS SHALL BE DESIGNED, SEALED AND SIGNED BY A
LICENSED PROFESSIONAL ENGINEER. THE CONTRACTOR SHALL SUBMIT SHOP
DRAWINGS, DESIGN LOAD DATA, SUPPORT REACTIONS, AND A CERTIFICATION THAT THE
ELEMENTS WERE DESIGNED FOR LOADS SPECIFIED IN THE CONTRACT DOCUMENTS OR
DESIGN CODES REFERENCED THEREIN. IF CRITERIA INDICATED ARE INSUFFICIENT,
CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR INFORMATION TO THE
CONTRACTING OFFICER.
ELEMENT
PILE CAPS
GRADE BEAMS, BEAMS,
COLUMNS, SLABS-ON-GRADE,
SLABS, AND WALLS
MIN. 28-DAY COMPRESSION STRENGTH (f'c)
36 MPa
36 MPa
1 kN/m2
PILE
LENGTH
(m)
PILE
DIAM
(mm)
406.4
WING DIAMETER
x PL THICKNESS
(mm x mm)
1,000 x 32
BEARING
CAPACITY
(kN)
1,639
UPLIFT
CAPACITY
(kN)
SHEAR
CAPACITY
(kN)
PILE
GRADE
STK 590
DESIGN LOADING (CONT'D)
6. SEISMIC LOADING
SITE LATITUDE & LONGITUDE
RISK CATEGORY
SEISMIC IMPORTANCE FACTOR
SOIL SITE CLASS
MAPPED SPECTRAL RESPONSE ACCELERATION FACTORS
SHORT PERIOD
1-SEC PERIOD
DESIGN SPECTRAL RESPONSE ACCELERATION FACTORS
SHORT PERIOD
1-SEC PERIOD
SEISMIC DESIGN CATEGORY
SEISMIC LATERAL FORCE RESISTING SYSTEM (SEE TABLE BELOW)
RESPONSE MODIFICATION COEFFICIENT
OVERSTRENGTH FACTOR
AMPLIFICATION FACTOR
ANALYSIS PROCEDURE
FUNDAMENTAL PERIOD (FROM MODAL ANALYSIS)
RESPONSE COEFFICIENT
DESIGN SEISMIC FORCE
LONGITUDINAL DIRECTION
TRANSVERSE DIRECTION
26.3408° N, 127.778° E
II
1.0 D
Ss = 1.73g S1 = 0.93g
Sds = 1.153g Sd1 = 1.054g
E (IBC 1613.2.5)
R = SEE TABLE
Ωo = SEE TABLE Cd = SEE TABLE
MODAL RSA (ASCE 7, Sec. 12.9)
T = SEE TABLE
Cs = SEE TABLE
V = 31,851 kN V = 36,791 kN
7. NON-STRUCTURAL COMPONENT ANCHORAGE, AS DESIGNED BY OTHERS IN ACCORDANCE WITH
ASCE 7 CHAPTER 13, AND MUST BE DESIGNED CONSIDERING THE ABOVE SEISMIC PARAMETERS
AND THOSE LISTED IN CHAPTER 11 OF ASCE 7, AS APPLICABLE.
DIRECTION
LONGITUDINAL
TRANSVERSE
SYSTEM (ASCE 7 TABLE 12.2-1)
D3. DUAL SYSTEM WITH SPECIAL
CONC SHEAR WALLS AND
MOMENT FRAMES
B4. SPECIAL CONCRETE SHEAR
WALL (BUILDING FRAME)
R
Ω0
2.5
2.5
Cd
5.5
Cs
16.4%
19.0%
T
0.447 s
0.451 s
13. PROVIDE CORNER BARS TO MATCH THE SIZE AND SPACING OF THE HORIZONTAL REINFORCEMENT AT CORNERS AND INTERSECTIONS. EACH LEG OF THE CORNER BAR SHALL BE THE TENSION LAP
SPLICE LENGTH, MINIMUM, PAST THE FACE OF THE PERPENDICULAR WALL.
14. PROVIDE CONSTRUCTION OR CONTROL JOINTS IN SLAB-ON-GRADE AS INDICATED IN THE
STUCTURAL DRAWINGS. IF JOINT PATTERN IS NOT INDICATED, PROVIDE JOINTS AT 4 METERS (±1000 MM) IN BOTH DIRECTIONS. JOINTS SHALL BE LOCATED TO CONFORM TO BAY SPACING WHEREVER
POSSIBLE (AT COLUMN CENTERLINES, HALF-BAYS, ETC.)
15. CONSTRUCTION JOINTS FOR JOISTS, BEAMS, GIRDERS AND ELEVATED SLABS SHALL BE AVOIDED WHERE POSSIBLE, BUT WHERE NECESSARY SHALL BE LOCATED IN THE MIDDLE 1/3 OF THE SPAN.
PLACE JOINTS SO THAT THEY DO NOT COMPROMISE THE STRENGTH OR PERFORMANCE OF THE
STRUCTURE. OFFSET JOINTS AT GIRDERS AT LEAST TWICE THE BEAM WIDTH FROM THE
BEAM/GIRDER INTERSECTION. CONTRACTOR MUST COORDINATE LOCATIONS OF CONSTRUCTION
JOINTS WITH STRUCTURAL DESIGNER OF RECORD.
16. THE SURFACE OF CONSTRUCTION JOINTS SHALL BE ROUGHED TO A FULL AMPLITUDE OF 6 MM. THE SURFACE OF THE CONSTRUCTION JOINTS SHALL BE CLEAN AND FREE OF LAITANCE. IMMEDIATELY
BEFORE NEW CONCRETE IS PLACED, CONSTRUCTION JOINTS SHALL BE WETTED AND STANDING
WATER SHALL BE REMOVED.
17. PROVIDE A COMPRESSIBLE FILLER AND SEALANT IN SLABS-ON-GRADE AND WALL AND COLUMN
INTERFACES THAT ARE NOT REQUIRED TO BE DOWELED TOGETHER PER THESE PLANS.
18. PIPES, CONDUITS, ETC., SHALL NOT BE EMBEDDED IN WALLS, COLUMNS OR BEAMS WITHOUT PRIOR
WRITTEN APPROVAL OF THE CONTRACTING OFFICER AND STRUCTURAL ENGINEER OF RECORD.
19. PROVIDE 100 mm HIGH CONCRETE HOUSEKEEPING PADS UNDER EQUIPMENT. PADS SHALL EXTEND BEYOND EQUIPMENT EXTENTS BY 150 mm (NOMINAL) ON ALL SIDES. APPLY BONDING AGENT TO
PREVIOUSLY CAST CONCRETE SLAB, PRIOR TO PLACING HOUSEKEEPING PAD CONCRETE. REFER
TO CONTRACT DRAWINGS FOR SIZE AND LOCATIONS OF EQUIPMENT.
20. PROVIDE 20 mm CHAMFERS AT ALL EXPOSED CORNERS OF CONCRETE, UNLESS NOTED OTHERWISE
PER ARCHITECTURAL DRAWINGS.
DRAFT
TYPICAL COLUMN ABOVEGRADE BEAMS, WHERE
OCCUR, PER PLAN
REINF AT BTM
MAT PER SCHED
D19@200
SKIN REINF
REINF AT BTM
MAT PER SCHED
PILE EMBED
H
50mm LWC (18 MPa)
60mm COMPACTED
BASE COURSE
NATIVE SOIL
INDICATES PILE
SCHEDULE NOTES:
1. PILE CAP SHORT SIDE LENGTH (B) IS LESS THAN THE LONG SIDE LENGTH (L), EXCEPT WHERE PILE CAP SIDES ARE EQUAL, I.E. B = L. WORK THIS
SCHEDULE WITH PILE ARRANGEMENT DIAGRAM PER AND PILE CAP PLAN DETAIL
2. ARRANGE PILES ACCORDING TO PILE COUNT (N) AND PILE ARRANGEMENT DIAGRAM PER
3. TOP OF PILE CAP ELEVATIONS PER PLAN.
4. PILE CAPS MUST BE FORMED. THE USE OF EARTH FORMS IS PROHIBITED.
5. PROVIDE CONTINUOUS REINFORCEMENT (NO SPLICES) AT TOP AND BOTTOM MAT BARS, EACH DIRECTION. STANDARD HOOKS REQUIRED AT
EACH END OF TOP AND BOTTOM MAT BARS.
6. PROVIDE CORNER BARS, IN THE PLANE OF THE TOP AND BOTTOM MATS, AT EACH CORNER. PROVIDE SPLICE LENGTH, MIN, AT EACH LEG.
7. MINIMUM CC PILE SPACING (S) IN SCHEDULE IS DETERMINED AS THE GREATER OF: (A) 1.5 x THE WING DIAMETER, OR (B) 2.5 x PILE DIAMETER (Dp). THE SPACING BETWEEN ADJACENT WINGS MUST BE AT LEAST 1 x PILE DIAMETER (Dp)
8. EDGE DISTANCE MEASURED FROM NEAREST EDGE OF PILE CAP TO FACE OF PILE CAP (OUTER DIAMETER).
TOPC
TOGB
NOTE: A PARTIAL SECTIONS IS SHOWN AT EACH HALF OF DETAIL,
REINFORCEMENT MATS REQUIRED OVER ENTIRE PLAN AREA, TYPICAL.
PILE CAP SHEAR REINF
8 S-502
8 S-502 2 S-502
Ld 3D
5D
EMBED DEPTH (100 mm)
BASE OF PILE CAP
D
D13 HOOPS @ 100
SEE SCHEDULE
BELOW
CONCRETE PLUG
AT STEEL PILE
CONDITION
ALL OTHER LOCATIONS
PILES AT CAPS AT
INDICATED COLUMNS
LOCATIONS
TYPICAL
A8, B6, B7, B8, B9, B11, B12, C9, C10
REINFORCEMENT
4-D25
8-D29
TYPICAL
COLUMN ABOVE
Ld
PROVIDE TO
MATCH COL VERT
BAR SIZE AND QTY
COL CONFINEMENT
REINFORCEMENT
PROVIDE CLOSED HOOPS
TO MATCH SIZE AND
SPACING OF
CONFINEMENT REINF AT
COLUMN THROUGH THE
FULL LENGTH OF THE
HOOKED DOWEL, TYPICAL
BOTTOM LAYER OF PILE CAP
REINF (BALANCE OF PILE CAP
REINF NOT SHOWN FOR CLARITY)
LONGITUDINAL REINF
FOR COL TO EXTEND TO
BTM REINF OF PILE CAP,
BUT MUST NOT BE LESS
THAN Ldh OR Ldt WHERE
HEADED REBAR IS USED
BENT REBAR SHOWN AT
COLUMN LONG BARS,
HOWEVER, HEADED REBAR
PERMITTED WHERE MEETS
REQUIREMENTS PER
DRAWINGS AND ACI 318.
CONCRETE
PLUG AT TOP OF
PILE PER 4 S-502
PILE SPLICE (AS
REQ'D) PER
DETAIL
WING AT
PILE TIP
ELEVATION OF TYPICAL PILE
BEARING LAYER
(AVG N ≥ 40)
MI
N
4D B
EY
ON
D
CO
NC
RE
TE
P
LU
G
PILE CAP NOT
SHOWN FOR
CLARITY
Dw
Dp m
(B
GS
7 S-502
PILE
TYPE
ALL
PILE
DIAMETER
(Dp)
406.4 mm
PILE WALL
THICKNESS
16 mm
PILE STEEL
GRADE
STK 590
WING
DIAMETER
(Dw)
1,000 mm
WING PLATE
THICKNESS
(tw)
32 mm
PILE SCHEDULE NOTES:
1. BEARING LAYER MUST HAVE MINIMUM AVERAGE BLOW COUNT OF N ≥ 40.
BEARING LAYER ESTIMATED TO BE 13 m BELOW GROUND SURFACE.
2. PILE SPLICES MUST USE CJP WELDS AND MUST BE PER PILE
MANUFACTURER RECOMMENDATIONS AND DETAILS. BACKING RINGS AND
STOPPERS PER MANUFACTURER.
3. WING PLATES MUST BE OPEN TYPE (OPENING AT WING PLATE).
4. WING PLATE STEEL MUST CONFORM TO JIS G 3106 (fy = 490 MPa MIN).
5. WING PLATES MUST BE INCLINED AT 14.4° ANGLE. REDUCTION IN WING
PLATE ANGLE MUST BE APPROVED BY CONTRACTING OFFICER AND
MANUFACTURER.
6. WING PLATES MUST BE CJP WELDED TO THE PILE SHAFT PER
MANUFACTURER'S RECOMMENDATIONS AND DETAILS.
7. PILE HEAD ROTATION TYPE INSTALL ACCEPTABLE, AS PERMITTED BY PILE
MANUFACTURER.
8. PILE THICKNESS HAS BEEN INCREASED BEYOND THE STRUCTURAL DESIGN
REQUIREMENTS TO PROVIDE 3.3 mm OF ADDITIONAL SACRIFICAL METAL
FOR CORROSION PROTECTION.
9. ________% OF PILES MUST BE PROOF LOADED TO ______% DESIGN
CAPACITY.
RO
OT
G
AP
≥ 4 5° f tp
CJP
OUTSIDE INSIDE
Dp
BACKING RING
STOPPER
NOTES:
1. "f" DISTANCE AND ROOT GAP PER MANUFACTURER
RECOMMENDATIONS.
2. STOPPER PLATE SIZE AND NUMBER OF PIECES PER
MANUFACTURER RECOMMENDATIONS.
3. BACKING RING GEOMETRY PER MANUFACTURER
RECOMMENDATIONS.
PILE WALL THICKNESS
(tp) PER SCHED
S
S S
S
N = 2 N = 3 N = 4
S
S
60°
60°
90°
S
S S
S
S S
S
N = 5 N = 6 N = 7
S/2 S S/2
S S
2 S
2 S
S/2 S S/2
S S
2 S
2 S
N = 8
S S
S S
N = 9 N = 10
S/2 S S S/2
S S S
2 S
2 S
S/2 S S S/2
S S S
2 S
2 S
N = 11
S S S
S S
N = 12
S/2 S S S/2
S S S
2 S
S
2 S
N = 14
NOTES:
1. PILE COUNT (N) AND CENTER-TO-CENTER SPACING (S) AS SPECIFIED PER PILE CAP SCHEDULE.
2. PILE ARRANGEMENTS SHOWN ARE DENSEST SPACING PERMITTED. NO TWO INDIVIDUAL PILES SHALL BE SPACED CLOSER THAN THE CENTER-TO-CENTER SPACING (S) AS SPECIFIED PER PILE CAP SCHEDULE.
3. ORIENTATION OF PILE GROUP TO MATCH PLAN ORIENTATION. PRINCIPLE AXES OF PILE GROUPS MUST ALIGN
WITH PRINCIPLE AXES OF PILE CAP.
4. CENTER OF PILE GROUP MUST ALIGN WITH CENTER OF PILE CAP CENTER.
5. COLUMN CENTROID OR CENTER OF WALL BOUNDARY ELEMENTS LOCATED OVER N = 3 PILE CAP MUST BE
LOCATED DIRECTLY OVER THE BARYCENTER OF THE THREE PILES.
6. PILES GROUPS N ≤ 9 ARE NOT PERMITTED WITH COMBINED PILE CAPS (TWO COLUMNS).
S
S
S
S
S
PLAN VIEW AT PILE CAP SUPPORTING ONE COLUMN (OR WALL)
(P4 PILE CAP SHOWN)
BUILDING COL
CENTERED AT
PILE CAP AND
PILE GROUP
NOTES:
1. A PARTIAL PLAN SECTION IS SHOWN AT EACH HALF OF DETAIL, REINFORCEMENT MATS REQUIRED OVER ENTIRE PLAN AREA, TYPICAL.
2. HOOKS AT ENDS OF REINFORCEMENT NOT SHOWN FOR CLARITY.
3. TYPICAL SECTION VIEW OF PILE CAP PER PILE CAP SCHEDULE
PLAN VIEW AT PILE CAP SUPPORT TWO COLUMNS
(P10 PILE CAP SHOWN)
INDICATES BUILDING
COL (ABOVE), LOC
RELATIVE TO PILE
CAP PER PLAN
DIMENSIONS
GRID
GRID
GRID
GRID
GRID
EQ EQ
WIDTH (B)
EQ
EQ
LE
NG
TH
(L
SYMM
SYMM
DI
ST
AN
CE
ED
GE
DISTANCE
EDGE
INDICATES B
REBAR
INDICATES L
REBAR
INDICATES L
REBAR
INDICATES B
REBAR
EQ
EQ
LE
NG
TH
(L
EQ EQ
WIDTH (B)
SYMM
SYMM
EQ
EQ
DISTANCE
EDGE
DI
ST
AN
CE
ED
GE
PE
R
SC
H E
DU
LE
TO
P
AN
D
BO
T
MA
T
TO
P
AN
D
BO
TT
OM
M
AT
P
ER
S
CH
ED
UL
E
1 S-502
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
DE
SI
GN
ED
B Y:
DR
AW
N
BY
SU
BM
IT
TE
D
BY
CH
EC
KE
D
BY
SI
ZE
IS
O A1
IS
SU
E
DA
TE
CO
NT
RA
CT
N O.
SO
LIC
IT
AT
IO
N
NO
SHEET ID
a
FI
LE
B.
F
IS
HE
R
B.
F
IS
HE
R
B.
F
IS
HE
R
S.
S
CH
NE
ID
ER
JU
LY
, 2
W
2H V2
1F
-P
S-502
BLDG P810
IN
TE
RM
ED
IA
TE
D
ES
IG
N
SU
BM
IT
TA
L 0 7/2
5/2
PI
LE
A
ND
P
ILE
C
AP
D
ET
AI
LS
PILE CAP
TYPE COUNT
PILE COUNT
(N)
PILE CC
SPACING (S)
CAP LENGTH
(L)
CAP WIDTH
(B)
EDGE
DISTANCE
(mm)
CAP THICKNESS
(H)
TOP B
REBAR
TOP L
REBAR
BOT B
REBAR
BOT L
REBAR
P1 8 1 1500 1005 1005 300 1000 5-D19 5-D19 5-D19 5-D19 P4 23 4 1500 2505 2505 300 1400 11-D25 11-D25 11-D25 11-D25 P5 1 5 1500 3130 3130 300 1400 14-D25 14-D25 14-D25 14-D25 P10 10 10 1500 5505 3605 300 1700 18-D22 30-D25 18-D25 30-D29 P12 2 12 1500 5505 4005 300 1700 20-D22 28-D25 20-D25 28-D29
NTS
PILE CAP SCHEDULE AND SECTION
NTS
PILE CONNECTION TO PILE CAP
COLUMN TO PILE CAP CONN
NTS
STEEL WING PILE
NTS
PILE SPLICE DETAIL
NTS
PILE ARRANGEMENT DIAGRAM
NTS
PILE CAP PLAN DETAIL
DRAFT
File details come from the government source that posted it. Updated .