P309_SACC_FOST_Intermediate_DrawingsVOL2.pdf
PDF 27 MB Posted
- Solicitation number
- W912HV25Z0012
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAFT
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Food Service_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
D A
N
IE
L
D A
N
IE
L
S T
A N
F O
R D P
S A
C
F O
S T
M e c h a n ic a l_
C e n tr a l_
.r vt
-0
-2
Q F
QF501
17 MARCH 2025 - 65% INTERMEDIATE DESIGN SUBMITTAL
E X
H A
U S
T H
O O
D D
E T
A
IL
S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Food Service_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
D A
N
IE
L
D A
N
IE
L
S T
A N
F O
R D P
S A
C
F O
S T
M e c h a n ic a l_
C e n tr a l_
.r vt
-0
-2
Q F
QF502
17 MARCH 2025 - 65% INTERMEDIATE DESIGN SUBMITTAL
E X
H A
U S
T H
O O
D D
E T
A
IL
S
M A
R K
D E
S C
R
IP
T
IO
N D
A
FIRE ALARM / MASS NOTIFICATION NOTES
THE FIRE ALARM SYSTEM MUST BE DESIGNED AND INSTALLED IN
ACCORDANCE WITH NFPA 72-2022 AND SPECIFICATION SECTION 28 31 76.
ALL DEVICES AND EQUIPMENT MUST BE UL LISTED OR FM APPROVED.
DEVICE LOCATIONS AND CONDUIT ROUTING ARE CONCEPTUAL. FINAL
QUANTITY AND LAYOUT MUST BE IN ACCORDANCE WITH APPLICABLE
CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT
LISTINGS. COORDINATE LOCATIONS WITH CEILING AND BELOW FLOOR
ELECTRICAL INSTALLATION.
ALL FIRE ALARM CONDUIT MUST BE 20 MM MINIMUM. ALL CONDUIT IN
FINISHED AREAS MUST BE CONCEALED.
SYNCHRONIZE ALL VISUAL NOTIFICATION APPLIANCES. SYNCHRONIZE ALL
AUDIBLE NOTIFICATION APPLIANCES.
THE FIRE ALARM SIGNAL MUST BE BY VOICE NOTIFICATION WITH A FEMALE VOICE.
VISUAL NOTIFICATION APPLIANCES MUST BE IN ACCORDANCE WITH
NFPA 72-2022. CANDELA RATINGS SHOWN ARE THE MINIMUM RATING
AFTER DERATING IF APPLICABLE.
SIGNALING LINE CIRCUITS MUST BE CLASS B, INITIATING DEVICE CIRCUITS
MUST BE CLASS B, NOTIFICATION APPLIANCE CIRCUITS MUST BE CLASS A.
SMOKE DETECTORS MUST BE LOCATED A MINIMUM OF 914 MM FROM SUPPLY
AND RETURN AIR DIFFUSERS.
PROVIDE SIGNAGE AT THE FIRE ALARM CONTROL PANEL IDENTIFYING THE
POWER PANEL AND CIRCUIT.
TESTING MUST INCLUDE INTELLIGIBILITY MEASUREMENTS. THE CIS VALUE
MUST BE 0.80 OR HIGHER.
1.
2.
3.
4.
5.
6.
7.
8.
10.
12.
9.
PROVIDE SIGNAGE AT ALL JUNCTION BOXES CONTAINING FIRE ALARM
MODULES.
11.
CONDUCTORS MUST BE PULLED SPLICE FREE FROM DEVICE TO DEVICE,
NO T-TAPPING OF ANY CIRCUITS IS ALLOWED.
14.
ALL PENETRATIONS THROUGH FIRE RATED WALLS MUST BE FIRESTOPPED.13.
ALL FIRE ALARM DEVICES IN MULTI-PURPOSE AREA MUST HAVE
PROTECTIVE COVERS.
15.
AUTOMATIC SPRINKLER SYSTEM NOTES
2. ALL DEVICES AND EQUIPMENT MUST BE UL LISTED OR FM APPROVED.
3. AN AUTOMATIC WET PIPE SPRINKLER PROTECTION MUST BE PROVIDED THROUGHOUT THE
PROJECT, AS INDICATED.
4. DESIGN WATER SUPPLY:
STATIC PRESSURE: 441 kPa RESIDUAL PRESSURE: 135 kPa
FLOW AT RESIDUAL PRESSURE: 7,491 LPM
WATER SUPPLY INFORMATION IS BASED ON HYDRANT TEST PERFORMED BY AMERICAN
ENGINEERING CORPORATION UNDER THE REMOTE SUPERVISION OF COFFMAN ENGINEERS ON
09/16/2022.
5. THE SPRINKLER SYSTEM MUST BE HYDRAULICALLY DESIGNED USING AREA/DENSITY METHOD IN
ACCORDANCE WITH NFPA 13 AND UFC 3-600-01:
OFFICES, CORRIDORS, SAC ACTIVITY ROOMS, COMMONS:
OCCUPANCY CLASSIFICATION: LIGHT HAZARD CEILINGS UP TO 9 M
DESIGN DENSITY: 4 LPM / M2
DESIGN AREA: 140 M2
HOSE STREAM: 950 LPM
SPRINKLER TYPE: QUICK RESPONSE, MINIMUM K=80
SPRINKLER TEMPERATURE: ORDINARY
MECHANICAL, ELECTRICAL, STORAGE, KITCHEN, FIRE PUMP ROOM:
OCCUPANCY CLASSIFICATION: LIGHT HAZARD CEILINGS FROM 9 M TO 13.7 M
DESIGN DENSITY: 8.0 LPM / M2
DESIGN AREA: 230 M2
HOSE STREAM: 950 LPM
SPRINKLER TYPE: QUICK RESPONSE, MINIMUM K=115
SPRINKLER TEMPERATURE: ORDINARY / INTERMEDIATE
*INTERMEDIATE TEMPEARATURE FOR KITCHEN
MULTIPURPOSE, CEILING > 9.1 M:
OCCUPANCY CLASSIFICATION: ORDINARY HAZARD CEILINGS UP TO 9 M
DESIGN DENSITY: 8 LPM / M2
DESIGN AREA: 230 M2
HOSE STREAM: 950 LPM
SPRINKLER TYPE: QUICK RESPONSE, MINIMUM K=115
SPRINKLER TEMPERATURE: ORDINARY / INTERMEDIATE
7.
8. THE PIPE ROUTING AND SPRINKLER LOCATIONS ARE CONCEPTUAL. THE CONTRACTOR MUST
INSTALL THE SYSTEM IN ACCORDANCE WITH THE APPLICABLE CODES, MANUFACTURER'S
RECOMMENDATIONS AND EQUIPMENT LISTINGS.
PROVIDE ELECTROLESS NICKEL COATED (CORROSION RESISTANT) SPRINKLERS IN EXTERIOR
LOCATIONS.
10. ALL SPRINKLERS MUST BE APPROVED QUICK RESPONSE TYPE.
11. PROVIDE INSPECTION AND HYDROSTATIC TESTS IN ACCORDANCE WITH NFPA 13.
12. SPARE SPRINKLERS MUST BE PROVIDED IN ACCORDANCE WITH NFPA 13. HYDRAULIC DATA PLATES
MUST BE PROVIDED AT THE RISER AND ALSO ABOVE THE FIRE SPRINKLER CABINET.
SPRINKLER DESIGN MUST INCLUDE A MINIMUM 10 PERCENT SAFETY FACTOR.
13. A PRESSURE RELIEF VALVE MUST BE PROVIDED AT THE RISER, INSPECTOR'S TEST
CONNECTION AND ON THE TEST AND DRAIN VALVE AS PART OF THE FLOOR CONTROL VALVE.
1. THE SPRINKLER SYSTEM DESIGN AND INSTALLATION MUST BE IN ACCORDANCE WITH
NFPA 13-2022, AND SPECIFICATION SECTION 21 13 13. THE CONTRACTOR MUST VERIFY
THE LOCATION OF ALL SPRINKLER SYSTEM COMPONENTS AND COORDINATE WITH THE
VARIOUS TRADES. I.E. FIRE ALARM, ELECTRICAL, ETC.
6. PIPING MUST BE PROVIDED WITH EARTHQUAKE PROTECTION IN ACCORDANCE WITH NFPA 13
AND SPECIFICATION SECTION 21 13 13. PROVIDE SEISMIC BRACING AND BRANCH LINE
RESTRAINTS THROUGHOUT THE BUILDING. SEISMIC CALCULATIONS MUST BE CALCULATED
WITH A CP FACTOR 0.82. SHOP DRAWINGS MUST SHOW ZONE OF INFLUENCES FOR SEISMIC
BRACING CALCULATED.
9.
14. ALL PENETRATIONS THROUGH FIRE RATED WALLS MUST BE FIRE STOPPED.
15.
16.
PIPING MUST NOT RUN INTO COMMUNICATIONS ROOMS. PROVIDE SIDE WALL SPRINKLERS WITH
GUARDS IN THESE ROOMS.
SPRINKLER PIPING MUST COMPLY WITH NFPA 13, EXCEPT THAT COPPER AND PLASTIC PIPE
MUST NOT BE PREMITTED. ALL PIPING IN AREAS WITH A TILE CEILING MUST BE CONCEALED.
SPRINKLER HEADS LOCATED IN THE MULTI-PURPOSE MUST BE PROVIDED WITH PROTECTIVE
GUARDS.
WET CHEMICAL SUPPRESSION SYSTEM NOTES
THE KITCHEN HOOD FIRE EXTINGUISHING SYSTEM SHALL BE DESIGNED IN
ACCORDANCE WITH NFPA 17A-2024, NFPA 96-2024, PROJECT
SPECIFICATIONS, AND UFC 3-600-01.
THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL THE SUPPRESSION
SYSTEM COMPONENTS AND COORDINATE WITH THE VARIOUS TRADES, I.E.
FIRE ALARM, ELECTRICAL, ETC.
ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM APPROVED
1.
2.
3.
UPON ACTIVATION, THE SYSTEM SHALL AUTOMATICALLY SHUT ALL
SOURCES OF GAS AND ELECTRIC TO THE EQUIPMENT BELOW THE
AFFECTED HOOD.
4.
UPON ACTUATION OF THE WET CHEMICAL SUPPRESSION SYSTEM AN
AUDIBLE ALARM OR VISUAL INDICATOR SHALL SHOW SYSTEM
ACTUATED
5.
UPON ACTUATION THE WET CHEMICAL SUPPRESSION SYSTEM SHALL
ACTUATE THE FIRE ALARM SIGNALING SYSTEM IN ACCORDANCE WITH
NFPA 72-2024.
6.
FTR
LOC
FEP
DESCRIPTION
OS&Y VALVE
CHECK VALVE
SYMBOL
WET PIPE FIRE SPRINKLER RISER
FIRE ALARM TRANSCEIVER
TAMPER SWITCH
LOCAL OPERATING CONSOLE PANEL, SEE DETAIL D7/FA501
PIPE / CONDUIT BREAK FOR CONTINUATION OR CLARITY
PIPE / CONDUIT UP, AS NOTED
PIPE / CONDUIT DOWN, AS NOTED
PORTABLE FIRE EXTINGUISHER LOCATION, SURFACE MOUNTED CABINET 3A:40B:C
BOOSTER POWER SUPPLY
FLOW SWITCH
DRAIN PIPED
PORTABLE FIRE EXTINGUISHER LOCATION, SEMI-RECESSED CABINET CLASS K
K
FS FIRE SPRINKLER PIPING
WC WET CHEMICAL KITCHEN HOOD FIRE EXTINGUISHER SYSTEM
MTR FIRE ALARM MASS NOTIFICATION TRANSCEIVER (MADAHCOM)
RADIO FIRE ALARM MASS NOTIFICATION ANTENNA
FIRE DEPARTMENT CONNECTION
FIRE PROTECTION SYMBOLS AND ABBREVIATIONS
SMOKE DETECTOR, CEILING MOUNTED, PHOTOELECTRIC
MANUAL DOUBLE-ACTION PULL STATION, MOUNTED 1220 MM AFF TO TOP
ADDRESSABLE OUTPUT MODULE
ADDRESSABLE INPUT MODULE
SP SURGE PROTECTOR
DOOR HOLDERDH
PUBLIC ADDRESS RELAY MODULE
PA
RELAY
FIRE ALARM MASS NOTIFICATION CONTROL PANELFMCP
ANN ANNUNCIATOR PANEL, SEE DETAIL A1/FA501
DUCT SMOKE DETECTOR
VS
WF
PS
S
F
AIM
AOM
R
FANT
MANT
RADIO FIRE ALARM ANTENNA
S
S C
SPEAKER ONLY, WALL MOUNTED
SPEAKER ONLY, CEILING MOUNTED
C
COMBINATION SPEAKER / VISUAL DEVICE, WALL MOUNTED, XX MINIMUM CANDELA SETTING
COMBINATION SPEAKER / VISUAL DEVICE, CEILING MOUNTED, XX MINIMUM CANDELA SETTING
VISUAL ONLY, CEILING MOUNTED, XX MINIMUM CANDELA SETTING
RTS REMOTE TEST SWITCH
XX
XX
XX
WP WEATHERPROOF
TYP TYPICAL
FIRE DEPARTMENT CONNECTIONFDC
UNO UNLESS NOTED OTHERWISE
S C
MASS NOTIFICATION SPEAKER, CEILING MOUNTED
MN
SEISMIC SYSTEM NOTES:
DESIGNATED SEISMIC SYSTEMS INCLUDE THE FIRE ALARM/MASS
NOTIFICATION PANEL. DESIGNATED SEISMIC SYSTEMS MUST PROVIDE
CERTIFICATION IN ACCORDANCE WITH ASCE 7-16.
PROVIDE COMPONENT IDENTIFICATION NAMEPLATE FOR DESIGNATED
SEISMIC SYSTEMS.
SPRINKLERS MUST BE INSTALLED WITH A 25 MM ANNULAR CLEARANCE
IN ACCORDANCE WITH ASTM E580, 5.2.8.5. PROVIDE SPRINKLERS WITH
LISTED ESCUTCHEONS THAT COMPLY WITH IBC-ASCE/SEI 7
REQUIREMENTS FOR USE IN SEISMIC DESIGN CATEGORIES C, D AND E.
1.
2.
3.
FLEXIBLE SPRINKLER HOSE FITTINGS WEIGHING LESS THAN 9kg MUST
BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN
RUNNERS OR TO BE CROSS TEES THAT HAVE THE SAME CARRYING
CAPACITY AS THE MAIN RUNNERS.
4.
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
J .H
IG
A
S H
I
J .P
IL
A
R C
A
R .B
IG
T
A S
P
S A
C
F O
S T
F ir e P ro te c ti o n C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
F -0
F-001
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E P
R O
T E
C T
IO
N
N O
T E
S
S Y
M B
O L
S A
N D
A B
B R
E V
IA
T
IO
N
S
M A
R K
D E
S C
R
IP
T
IO
N D
A
DRAFTA
1 2 4 5 63
C
D
F
B
E
7 8
B.2
1A
AA
6.9
55 56 57
MULT-PURPOSE
ROOM STORAGE
MULTI-PURPOSE
ROOM
COMMONS
JANITOR
GIRLS TOILET RM
MECHANICAL
EQUIPMENT
BOYS TOILET RM
SAC ACTIVITY ROOM
STORAGE
123B
STORAGE
123C
CHECK-IN
OFFICE
MEN'S R.R.
OFFICE
KITCHEN
MECHANICAL
EQUIPMENT
WOMEN'S R.R.
PRINT ROOM
STORAGE
BREAK ROOM /
STAFF TRAINING
COMMS/CCTV
106ISOLATION
STAFF CORRIDOR
ELECTRICAL
LOBBY
SAC ACTIVITY ROOM
SAC ACTIVITY ROOM
STORAGE
121C
SAC ACTIVITY ROOM
STORAGE
124B
STORAGE
124C
STORAGE
121B
STORAGE
122B
STORAGE
122C
FA101
A1
FA102
A1
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
10 m
1:200
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
J .H
IG
A
S H
I
J .P
IL
A
R C
A
R .B
IG
T
A S
P
S A
C
F O
S T
F ir e P ro te c ti o n C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
F A
FA100
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E A
L A
R M
A
S S
N O
T
IF
IC
A
T
IO
N O
V E
R A
L L
F L
O O
R P
L A
N
1 : 2001
OVERALL FLOOR PLAN - FIRE ALARM/MASS NOTIFICATION SYSTEM
M A
R K
D E
S C
R
IP
T
IO
N D
A
F M
C P
F
F
F
F
P S
F
F
F
F
F
F T
R M
T R
F E
P F
E P
L O
C A
N N
F
F
75 75
75 75
S C
S C
S C
S C
15 15
C
C
C
C
C
C
C
C
C
C
S
C S
C C
C
C
VS
P S
/ M A
T C
H L
IN
E
A
F A
2A
1 2 4 5 63
C
D
F
B
E
7 8
B.2
1A
6.9
55 56 57
MULT-PURPOSE
ROOM STORAGE
MULTI-PURPOSE
ROOM
COMMONS
JANITOR
GIRLS TOILET RM
MECHANICAL
EQUIPMENT
BOYS TOILET RM
SAC ACTIVITY
ROOM
STORAGE
123B
STORAGE
123C
CHECK-IN
VESTIBULE
SAC ACTIVITY
ROOM
SAC ACTIVITY
ROOM
STORAGE
121C
SAC ACTIVITY
ROOM
STORAGE
124B
STORAGE
124C
STORAGE
121B
STORAGE
122B
STORAGE
122C
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
J .H
IG
A
S H
I
J .P
IL
A
R C
A
R .B
IG
T
A S
P
S A
C
F O
S T
F ir e P ro te c ti o n C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
F A
FA101
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E A
L A
R M
M
A S
S N
O T
IF
IC
A T
IO
N
S Y
S T
E M
F L
O O
R P
L A
N
A R
E A
A
1 : 100A1
FIRE ALARM/MASS NOTIFICATION SYSTEM FLOOR PLAN - AREA A
M A
R K
D E
S C
R
IP
T
IO
N D
A
F
M C
P
F
P S
F
F
F
F
F
F T
R M
T R
F E
P F
E P
L O
C A
N N
F
C
C
C
C
C
MR
WC
F A
N T
MANT
C
C
C
C
C
15C
C
C
C
C
VS
P S
/ M A
T C
H L
IN
E
A
F A
A
C
D
E
7 8
B.2
1A
AA
6.9
CHECK-IN
OFFICE
MEN'S R.R.
OFFICE
KITCHEN
MECHANICAL
EQUIPMENT
WOMEN'S R.R.
PRINT ROOM
STORAGE
BREAK ROOM /
STAFF TRAINING
COMMS/CCTV
ISOLATION
STAFF CORRIDOR
ELECTRICAL
LOBBY
VESTIBULE
STORAGE
121C
STORAGE
121B
STORAGE
122B
STORAGE
122C
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
J .H
IG
A
S H
I
J .P
IL
A
R C
A
R .B
IG
T
A S
P
S A
C
F O
S T
F ir e P ro te c ti o n C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
F A
FA102
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E A
L A
R M
M
A S
S N
O T
IF
IC
A T
IO
N
S Y
S T
E M
F L
O O
R P
L A
N
A R
E A
B
1 : 100A1
FIRE ALARM/MASS NOTIFICATION SYSTEM FLOOR PLAN - AREA B
FIRE ALARM NOTES
PROVIDE CONNECTION TO KITCHEN HOOD
EXTINGUISHING SYSTEM
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
MANUAL ACTIVATION STATION WET
CHEMICAL SYSTEM, HOOD 1
WET CHEMICAL EXTINGUISHING
SYSTEM, WALL MOUNTED
WET CHEMICAL SUPPRESSION SYSTEM NOTES
1. REFER TO SHEET F-001 FOR ADDITIONAL NOTES.
2. PROVIDE NEW WET CHEMICAL SUPPRESSION SYSTEM
INCLUDING, BUT NOT LIMITED TO PIPING, NOZZLES,
TANKS, DETECTION LINE, AND ACCESSORIES TO
PROTECT ASSOCIATED EXHAUST HOOD ONE IN
ACCORDANCE WITH NFPA 17A-2024, NFPA 96-2024, & THE
MANUFACTURER'S RECOMMENDATIONS.
3. CONFIRM WET CHEMICAL SUPPRESSION CYLINDER
SPACE REQUIREMENTS WITH MANUFACTURER AND FIELD
VERIFY AVAILABLE WALL SPACE TO INSTALL WET
CHEMICAL SUPPRESSION SYSTEM CYLINDERS PRIOR TO
ORDERING EQUIPMENT (TYP OF ALL HOODS).
4. PROVIDE NECESSARY EQUIPMENT TO SHUT OFF FUEL TO
ALL APPLIANCES UNDER THE EXHAUST HOOD WHEN
SYSTEM IS ACTUATED.
5. PROVIDE NEW FIRE ALARM MODULES AS NECESSARY TO
ACTIVATE THE BUILDING FIRE ALARM SYSTEM WHEN WET
CHEMICAL SYSTEM IS ACTUATED.
6. COORDINATE POWER SHUT OFF TO APPLIANCES UNDER
EXHAUST HOOD WHEN WET CHEMICAL SUPPRESSION
SYSTEM IS ACTUATED.
7. COORDINATE ALL WORK WITH MECHANICAL DWGS FOR
KITCHEN EXHAUST SYSTEM.
MOUNT FIRE ALARM AND MASS NOTIFICATION ANTENNAS
AT HIGHEST POINT ON BUILDING AND AT LEAST 6.1 M (20
FEET) FACE ANTENNA TOWARD BASE RECEIVING
STATION.
DRAFTA
1 2 4 5 63
C
D
F
B
E
7 8
B.2
1A
AA
6.9
55 56 57
MULT-PURPOSE
ROOM STORAGE
MULTI-PURPOSE
ROOM
COMMONS
JANITOR
GIRLS TOILET RM
MECHANICAL
EQUIPMENT
BOYS TOILET RM
127 SAC ACTIVITY
ROOM
STORAGE
123B
CHECK-IN
OFFICE
MEN'S R.R.
103 OFFICE
KITCHEN
MECHANICAL
EQUIPMENT
WOMEN'S R.R.
PRINT ROOM
STORAGE
BREAK ROOM /
STAFF TRAINING
COMMS/CCTV
ISOLATION
STAFF CORRIDOR
ELECTRICAL
LOBBY
VESTIBULE
SAC ACTIVITY
ROOM
SAC ACTIVITY
ROOM
STORAGE
121C
SAC ACTIVITY
ROOM
STORAGE
124B
STORAGE
124C
STORAGE
121B
STORAGE
122B
STORAGE
122C
PROVIDE AUTOMATIC WET-PIPE SPRINKLER
PROTECTION WITHIN THIS BOUNDARY
PROVIDE AUTOMATIC WET-PIPE SPRINKLER
PROTECTION WITHIN THIS BOUNDARY
FX101
A1
FX102
A1
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
10 m
1:200
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
D e s ig n e r
A u th o r
C h e c k e r
M M
-D D
-Y Y
Y Y
F X
FX100
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E S
P R
IN
K
L E
R O
V E
R A
L L
F L
O O
R P
L A
N
1 : 2001
OVERALL FLOOR PLAN - FIRE SPRINKLER
M A
R K
D E
S C
R
IP
T
IO
N D
A
FIRE SPRINKLER HAZARD
CLASSIFICATION LEGEND
DESCRIPTION
LIGHT HAZARD
SYMBOL
ORDINARY HAZARD
A
1 2 4 5 63
C
D
F
B
E
7 8
B.2
1A
6.9
55 56 57
MULT-PURPOSE
ROOM STORAGE
MULTI-PURPOSE
ROOM
COMMONS
JANITOR
GIRLS TOILET RM
MECHANICAL
EQUIPMENT
BOYS TOILET RM
SAC ACTIVITY
ROOM
STORAGE
123B
STORAGE
123C
VESTIBULE
SAC ACTIVITY
ROOM
SAC ACTIVITY
ROOM
STORAGE
121C
SAC ACTIVITY
ROOM
STORAGE
124B
STORAGE
124C
STORAGE
121B
STORAGE
122B
STORAGE
122C
PROVIDE AUTOMATIC WET-PIPE
SPRINKLER PROTECTION WITHIN
THIS BOUNDARY
M
A T
C H
L
IN
E
A
F X
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
J .H
IG
A
S H
I
J .P
IL
A
R C
A
R .B
IG
T
A S
P
S A
C
F O
S T
F ir e P ro te c ti o n C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
F X
FX101
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E S
P R
IN
K
L E
R F
L O
O R
P L
A N
A
R E
A A
1 : 100A1
FIRE SPRINKLER FLOOR PLAN - AREA A
M A
R K
D E
S C
R
IP
T
IO
N D
A
FIRE SPRINKLER HAZARD
CLASSIFICATION LEGEND
DESCRIPTION
LIGHT HAZARD
SYMBOL
ORDINARY HAZARD
A
C
D
E
7 8
B.2
1A
AA
CHECK-IN
OFFICE
MEN'S R.R.
OFFICE
KITCHEN
MECHANICAL
EQUIPMENT
WOMEN'S R.R.
PRINT ROOM
STORAGE
BREAK ROOM /
STAFF TRAINING
COMMS/CCTV
ISOLATION
STAFF CORRIDOR
ELECTRICAL
LOBBY
VESTIBULE
PROVIDE AUTOMATIC WET-
PIPE SPRINKLER
PROTECTION WITHIN THIS
BOUNDARY
M
A T
C H
L
IN
E
A
F X
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
J .H
IG
A
S H
I
J .P
IL
A
R C
A
R .B
IG
T
A S
P
S A
C
F O
S T
F ir e P ro te c ti o n C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
F X
FX102
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E S
P R
IN
K
L E
R F
L O
O R
P L
A N
A
R E
A B
1 : 100A1
FIRE SPRINKLER FLOOR PLAN - AREA B
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
WET-PIPE SPRINKLER
RISER, SEE DETAIL
D1/FX501
TOP OF DETECTOR
ACCEPTABLE HERE
DETECTOR
LOCATION
IS ACCEPTABLE
HERE
ABOVE ACCEPTABLE HEIGHT
BELOW ACCEPTABLE HEIGHT
CEILING
SIDEWALL
M
M M
A X
IM
U
M
T O
F R
O M
P E
A K
O F
R O
O F
CONC SLAB
RADIO FIRE ALARM
INTERFACE PANEL
AND TRANSMITTER
1" GALVANIZED
RIGID
CONDUIT
CONDUIT CLAMP
GRADE
TO GROUNDING
ROD AND BUILDING
GROUND
EXTERIOR WALL
ROOF
PROVIDE SUPPORT
FOR VERTICAL
PORTION OF
RACEWAY ABOVE
ROOF
LIGHTNING ARRESTOR, SEE
DETAIL "A1" THIS SHEET
PROVIDE 1"
CONDUIT SUPPORT
FOR VERTICAL
PORTION OF
RACEWAY ABOVE
ROOF
ALERT
VISUAL OR AUDIO/
VISUAL DEVICE
MANUAL FIRE
ALARM PULL
STATION
AUDIO DEVICE
M
M
M
M
M
M
M A
X
IM
U M
5'-0" MAX.
* IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR AUDIO DEVICES WHILE
LEAVING A MINIMUM OF 150 MM (6-INCHES) BETWEEN THE CEILING AND THE TOP OF THE AUDIO DEVICE, THE DEVICE MUST BE MOUNTED AT 150 MM (6-INCHES) BELOW CEILING MEASURED TO THE TOP OF THE
DEVICE.
** IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR VISUAL OR AUDIO/ VISUAL
DEVICES WHILE LEAVING A MINIMUM OF 6-INCHES BETWEEN THE CEILING AND THE TOP OF THE
VISUAL OR AUDIO/ VISUAL DEVICE, THE DEVICE MUST BE MOUNTED AT 6-INCHES BELOW CEILING
MEASURED TO THE TOP OF THE DEVICE.
1524 MM MAX.
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
D e s ig n e r
A u th o r
C h e c k e r
P
S A
C
F O
S T
F ir e P ro te c ti o n C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
F A
FA501
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E A
L A
R M
M
A S
S N
O T
IF
IC
A T
IO
N
D E
T A
IL
S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
NTS
SPRINKLER LOCATIONS FOR TILE CEILINGS
NTS
ANTENNA MOUNTING DETAIL
NTS
SPRINKLER LOCATIONS FOR TILE CEILINGS
D1
A1
D7
DRAFT ALARM - PULL STATIONS
ALARM - WATERFLOW SWITCHES, KITCHEN HOOD SYSTEM
ALARM - SMOKE DETECTORS
ALARM - PUMP RUNNING
COMMON TROUBLE
RADIO FIRE ALARM TRANSCEIVER ZONES
MASS NOTIFICATION SUPERVISORY
SUPERVISORY
PUMP TROUBLE
A C
TIV
A
TE A
U D
IO
F
IR
E A
LA
R M
S
IG
N A L
SYSTEM INPUT
A N N U N C
IA
TE S
U P
ER
V
IS
O R Y Z
O N E A
T B U
IL
D
IN
G F
M C P
A N N U N C
IA
TE
A
LA
R M
Z O N E A
T B U
IL
D
IN
G F
M C P
FIRE ALARM / MASS NOTIFICATION SYSTEM SEQUENCE OF OPERATIONS
SYSTEM OUTPUT**
A
B
C
D
E
F
H
D
EA
C
TIV
A
TE
A U D
IO
F
IR
E A
LA
R M
S
IG
N A L
MANUAL PULL STATION ACTIVATES INTO ALARM
ACTIVATION OF CEILING SMOKE DETECTOR
SPRINKLER SYSTEM TAMPER SWITCH ACTIVATES INTO ALARM
SPRINKLER SYSTEM WATERFLOW SWITCH ACTIVATES INTO ALARM
1 2 3 4 5 6 7 8 9
A N N U N C
IA
TE
T
R O U
BLE
Z O
N E A
T B U
IL
D
IN
G F
M C P
A C
TIV
A
TE V
IS
U
AL
A
LA
R M
S
TR
A N
SM
IT
S
IG
N A L
V
IA
R
AD
IO
F
IR
E A
LA
R M
S
YSTE
M
10 11 12 13 14
M U
TE S
O U N D S
YS
TEM
T H R O
U G
H O U T S
C H O O L
R
ELE
AS
E S
M O
KE
B A R R
IE
R D
O O R S
I
J
K
L
M
N
G
S H U T D
O W
N A
IR
H
AN
D
LE
R
ACTIVATION OF DUCT SMOKE DETECTOR
SYSTEM TROUBLE
ACTIVATION OF MASS NOTIFICATION SYSTEM (TRX)
ACTIVATION OF KITCHEN HOOD EXTINGUISHING SYSTEM
TROUBLE ON POWER EXTENDER PANEL
ACTIVATION OF FIRE ALARM SYSTEM (MICROPHONE)
1 2 3 4 5 6 7 8 9 10 11 12 13 14
TU
R N O
N O
C C U P A N C Y S
E N S O R L
IG
H
TIN
G C
O N
TR
O
LS
B R O
AD
C
AS
T M
AS
S N O
TIF
IC
A
TIO
N M
E
SS
AG
E IN
A D M
IN
O
FFIC
E
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A C
TIV
A
TE D
O O R R
E
LE
AS
E
SPRINKLER ZONE 2-5 WATERFLOW SWITCH ACTIVATES INTO ALARM
KNOX BOX TAMPER SWITCH ACTIVATES INTO ALARM
ACTIVATION OF POLICE ALARM FROM SECURITY SYSTEM
B R O
AD
C
AS
T M
AS
S N O
TIF
IC
A
TIO
N L
O C
KD
O W
N M
E
SS
AG
E
IN
A
LL
Z O
N
ES
TROUBLE ON TWO-WAY COMMUNICATION SYSTEM
A
B
C
D
E
F
H
I
J
K
L
M
N
G
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
D e s ig n e r
A u th o r
C h e c k e r
P
S A
C
F O
S T
F ir e P ro te c ti o n C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
F A
FA601
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E A
L A
R M
M
A S
S N
O T
IF
IC
A T
IO
N
S Y
S T
E M
S E
Q U
E N
C E
O F
O P
E R
A T
IO
N
D1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
NTS
FIRE ALARM/MASS NOTIFICATION SYSTEM SEQUENCE OF OPERATIONS
12"
36"
24"24"
24"24"
12"36"
12"12"
600X600 (24" X 24") CEILING TILE
600X1200 (24" X 48") CEILING TILE
600X1200 (24" X 48") CEILING TILE
300X1200 (12" X 48") CEILING TILE
300X1200 (12" X 48") CEILING TILE
600 MM 600 MM
M
M M
M
600 MM
M
M
600 MM
300 MM
M
M
900 MM
300 MM300 MM
M
M M
M
300 MM
M
M
900 MM
M
M
CONC SLAB
ALL THREAD
ROD (TYP) *
END OF BRANCH
LINE SURGE
RETAINER CLIP
ANCHOR (TYP)
ADJUSTABLE
RING HANGER
ROD COUPLING
ROD SIZE MUST BE DETERMINED BY CALCULATIONS
WHERE L/R DOES NOT EXCEED 400
CONC SLAB
SWAY BRACE FITTINGS
SCHEDULE 40 PIPE *
PIPE CLAMP
SPRINKLER CROSSMAIN
* PIPE SIZE MUST BE DETERMINED BY CALCULATIONS
ANCHOR (TYP) CONC SLAB
SWAY BRACE FITTINGS
SCHEDULE 40 PIPE *
SPRINKLER
CROSS MAIN
ANCHOR
PIPE CLAMP
* PIPE SIZE MUST BE DETERMINED BY CALCULATIONS
AUTO SPKR
PRESSURE GAUGES
50 MM (2") DRAIN,
TERMINATE 150 MM (6")
ABOVE SPLASH BLOCK
CHECK VALVE
4 - 65 MM (2 1/2") X
100 MM (4") FIRE
DEPARTMENT
CONN.
762 MM (2'-6")
ABOVE GRADE
SPLASH BLOCK
CONCRETE THRUST BLOCK AT
BASE OF RISER 0.93 SM (10.0
SF) MINIMUM OF BEARING
SURFACE
PROVIDE 4-WAY SWAY BRACING
AT TOP AND BOTTOM OF RISER
RISER CHECK VALVE
FLEXIBLE COUPLING WITHIN 600 MM
(24") OF TOP AND BOTTOM OF THE
RISER (TYP)
DRAIN LINE (DRAIN MUST NOT BE
CONNECTED TO THE MAIN DRAIN)
OS&Y CONTROL VALVE
W/TAMPER SWITCH (TYP.)
UNDER GROUND WATER SUPPLY, SEE
CIVIL DRAWINGS FOR CONTINUATION
20 MM (3/4") STEEL TIE RODS,
BITUMASTIC COATED
25 MM (1") PRESSURE RELIEF
VALVE SET AT 1.2 MPA (175 PSI)
VS
WF
INSULATING FLANGE
PROVIDE ANNULAR CLEARANCE
IAW NFPA 13
TEST HEADER
4 - 65 MM (2 1/2") HOSE VALVES
X 100 MM (4") TEST HEADER
CONN. 762 MM (2'-6") ABOVE
GRADE
OS&Y VALVE WITH
LOCK AND CHAIN
OS&Y CONTROL VALVE
W/ CHAIN AND LOCK
NEW 200 MM (8") DOUBLE CHECK VALVE
BACKFLOW PREVENTER ASSEMBLY,
MTD IN THE VERTICAL POSITION
NOTES:
1, POLYETHYLENE, MYLAR AND PHENOLIC INSULATING SLEEVES AND
WASHERS ARE NOT ACCEPTABLE AND WILL BE REJECTED. PROVIDE
NEMA G-10 TYPE INSULATING SLEEVES AND WASHERS.
2. DOUBLE INSULATING WASHERS ARE REQURIED (ONE FOR EACH SIDE
OF EACH FLANGE ROD)
3. FULL FACE GASKETS REQUIRED. GASKET RETAINER MUST BE HIGH
COMPRESSIVE STRENGTH ASTM G-10 MATERIAL.
4. NEW GRADE 8 BOLT AND NUTS REQUIRED FOR EACH FLANGE.
5. HARDWARE QUANTITIES IN INSULATING FLANGE KIT WILL VARY
BASED ON GASKET PATTERN AND PIPE SIZE.
6. DO NOT COAT OR SPRAY INSULATING COMPONENTS WITH GREASE.
7. AFTER INSTULATING FLANGE KIT IS COMPLETELY INSTALLED, WRAP
FLANGE WITH MINIM 3 LAYERS OF PIPE JOINT TAPE WRAP.
FULL LENGTH
INSULATING SLEEVE
USE NEMA G-10
MATERIAL
STEEL WASHER (TYP)
INSULATING WASHER
ON BOTH SIDES OF
FLANGE (USE NEMA
G-10)
FLANGE NUT (TYP)
FLANGE BOLT
(TYP)
INSULATING
GASKET (NEMA
G-10 RETAINER)
BITUMASTIC
COATED TIE
RODS, SIZE IN
ACCORDANCE
WITH NFPA 13
(TYP)
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T
C
IN
C
IN
N A
T I, O
H
IO
D e s ig n e r
A u th o r
C h e c k e r
P
S A
C
F O
S T
F ir e P ro te c ti o n C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
F X
FX501
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
E S
P R
IN
K
L E
R D
E T
A
IL
S
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
NTS
SEISMIC BRACING END-HEAD (CONC)
NTS
SEISMIC BRACING LATERAL SWAY (CONC)
NTS
SEISMIC BRACING LONGITUDINAL SWAY (CONC)
NTS
WET SPRINKLER RISER DETAIL
NTS
SPRINKLER LOCATIONS FOR TILE CEILINGS
A1 A4 A7
E7
D1
NTS
DIELECTRIC INSULATING FLANGE DETAIL
D5
STANDARD PLUMBING SYMBOLS
GENERAL SYMBOLS
PLUMBING SYMBOLS
NOTES:
SANITARY WASTE STACK AND VENT NUMBER
KITCHEN EQUIPMENT/LABORATORY EQUIPMENT NUMBER
ROOF LEADER/DOWNSPOUT NUMBER
FLOOR PENETRATION LINE (ISOMETRIC)
VENT THRU ROOF (ISOMETRIC)
PIPE UP TO FIXTURE OR EQUIPMENT INDICATED
WATER ISOMETRIC NUMBER
INTERCEPTOR W/ TYPE (G=GREASE; O=OIL)
BACKWATER VALVE
BACKFLOW PREVENTER (RP=REDUCED PRESSURE;
DC=DUAL CHECK)
HUB DRAIN OUTLET W/ TRAP
FLOOR DRAIN W/ TRAP
RUNNING TRAP W/ CLEANOUT
COLD WATER
HOT WATER
HOT WATER RETURN
VENT PIPING
ROOF DRAIN
ROOF DRAIN W/ SCUPPER DRAIN
PIPING ABOVE FLOOR OR GRADE
(ABV=TYPE; SEE ABBREVIATIONS)
PIPING BELOW FLOOR OR GRADE
(ABV=TYPE; SEE ABBREVIATIONS)
FLOOR OR GRADE CLEANOUT
CATCH BASIN W/ DESIGNATION
MANHOLE W/ DESIGNATION
HOT WATER WITH HEAT TRACE
45 DEGREE DROP
PIPE ELBOW DOWN
PIPE ELBOW UP
UNION
THERMOMETER WELL
CONCENTRIC REDUCER
ECCENTRIC REDUCER
FLEXIBLE CONNECTION
PLUG VALVE
O.S. & Y VALVE
QUICK OPENING VALVE
PIPE TEE DOWN
PIPE TEE UP
BLOW-OFF STRAINER
ABBREVIATION OF PIPE CONTENTS
AUTOMATIC FLOW CONTROL VALVE
AUTOMATIC AIR VENT
PUMP
ABBREVIATION OF ITEM
THERMOMETER
PRESSURE GAGE & COCK
MANUAL AIR VENT
(SELF CONTAINED)
TRAP, STEAM W/ TYPE (F & T = FLOAT &
THERMOSTAT; BT = BUCKET, TT = THERMOSTATIC)
PIPE CAP
ALIGNMENT GUIDE (A = TYPE)
ANCHOR (A =TYPE)
EXPANSION JOINT (A = TYPE)
EXPANSION LOOP
FLEXIBLE CONNECTOR
PITCH OF PIPE (R = RISE; D = DROP)
IN DIRECTION OF FLOW
PUMP SUCTION DIFFUSER
PRESSURE/TEMPERATURE PORT
BALL VALVE
BUTTERFLY VALVE
GATE VALVE
GLOBE VALVE
RELIEF VALVE
BALANCING VALVE
PRESSURE REDUCING VALVE
CHECK VALVE
CALIBRATED BALANCING VALVE
CHECK VALVE W/BALL DRIP
GATE ANGLE VALVE
GLOBE ANGLE VALVE
STRAINER
A THIS LEGEND IS COMPOSED OF STANDARD SYMBOLS
AND APPLIES TO THE SET OF DRAWINGS TO THE EXTENT
APPLICABLE.
DETAIL OR SECTION BUBBLE
USE "LETTERS" FOR SECTIONS
USE "NUMBERS" FOR DETAILS
EQUIPMENT MARK NUMBER
SHEET NUMBER WHERE SECTION/DETAIL IS SHOWN
ABBREVIATION OF ITEM
G
X
AHU-1
A
M3
ABV.
R2
S1
(ABV)
(ABV)
CB-1
MH-1
AAV
MAV
TW
ABV.
A
A
A
ABV
F & T
R
PSD
DRAWING NOTE HEX
CONNECT TO EXISTING
DETAIL OUTLINE
PIPING SYMBOLS
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -0
P-001
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
A B
B R
E V
IA
T
IO
N
S A
N D
G E
N E
R A
L N
O T
E S
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
ASHP AIR SOURCE HEAT PUMP
BFP BACKFLOW PREVENTER
BP BOOSTER PUMP
BR BRINE TANK
C CENTIGRADE TEMPERATURE
CO CLEAN OUT
CP CIRCULATING PUMP
DCW DOMESTIC COLD WATER
DFU DRAINAGE FIXTURE UNITS
DHWR DOMESTIC HOT WATER RETURN
DHWS DOMESTIC HOT WATER SUPPLY
DIA DIAMETER
DWG DRAWING
EL or ELEV ELEVATION
ET EXPANSION TANK
EW EMERGENCY EYE/FACE WASH
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FPWH FREEZEPROOF WALL HYDRANT
FS FLOOR SINK
GCO GRADE CLEANOUT
GI GREASE INTERCEPTOR
GW GREASE WASTE SEWER
GWH GAS WATER HEATER
HB HOSE BIBB
HP HORSEPOWER
HZ HERTZ
KG KILOGRAM
KW KILOWATT
KWH KILOWATT-HOUR
L**** LAVATORY
L**** LITERS
LPS LITERS PER SECOND
M METERS
MAX MAXIMUM
MCA MINIMUM CIRCUIT AMPS
MG MILLIGRAMS
MIN MINIMUM
MM MILIMETERS
MOCP MINIMUM OVERCURRENT PROTECTION
MS MOP SINK
NTS NOT TO SCALE
P PUMP
PH PHASE
PPM PARTS PER MILLION
R RADON
RCP RECIRCULATING PUMP
RPM REVOLUTIONS PER MINUTE
S SECOND(S)
SAN SANITARY SEWER
SF SOFTENER
SH SHOWER
SI SOLIDS INTERCEPTOR
SK SINK
SS SERVICE SINK
ST STORAGE TANK
TMV THERMOSTATIC MIXING VALVE
TYP TYPICAL
PLUMBING ABBREVIATIONS
UG UNDERGROUND
UR URINAL
V**** VENT
V**** VOLT
VTR VENT THROUGH ROOF
W WATTS
WC WATER CLOSET
WCO WALL CLEANOUT
WH WALL HYDRANT
WHA WATER HAMMER ARRESTOR
M A
R K
D E
S C
R
IP
T
IO
N D
A of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -0
P-002
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
G E
N E
R A
L N
O T
E S
A ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH
INTERNATIONAL PLUMBING CODE, JAPAN DISTRICT DESIGN
GUIDE, AND ALL APPLICABLE UFC'S, LOCAL PLUMBING CODES
AND ORDINANCES.
B TOPS OF ALL FLOOR DRAINS AND CLEANOUTS SHALL BE SET
FLUSH WITH FINISHED FLOOR.
C ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED BY
THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING
TILES OR CEILING STRUCTURE.
D THE PLUMBING CONTRACTORS AND EQUIPMENT SUPPLIERS
SHALL COMPARE THE ELECTRICAL POWER REQUIREMENTS OF
THE INTENDED AS SPECIFIED WITH THE POWER
CHARACTERISTICS TO THE EQUIPMENT AS SHOWN ON THE
ELECTRICAL DRAWINGS. SHOULD THE SELECTED EQUIPMENT AS
FURNISHED BY THE CONTRACTOR REQUIRE A LARGER REVISION
OF ITS BRANCH FEEDER, THE ADDED COSTS SHALL BE BORNE BY
THE CONTRACTOR FURNISHING THE EQUIPMENT.
E ALL PLUMBING EQUIPMENT SHALL BE INSTALLED ACCORDING TO
MANUFACTURER'S RECOMMENDATIONS.
F ALL PLUMBING EQUIPMENT, PIPING INSULATION, ETC. INSTALLED
IN HVAC PLENUM SPACES SHALL MEET CODE REQUIREMENTS
FOR SMOKING AND COMBUSTIBILITY.
G ALL HORIZONTAL STORM, SOIL AND WASTE PIPING SHALL BE
SLOPED PER INTERNATIONAL PLUMBING CODE (IPC) AND MUST
BE PROVIDED WITH A MINIMUM SLOPE GREATER THAN 1% PER
UFC 3-420-01.
H FURNISH ALL MATERIALS, EQUIPMENT AND INSTRUMENTS
NECESSARY TO CONDUCT ALL TESTING OF PLUMBING PIPING
SYSTEMS IN ACCORDANCE WITH THE INTERNATIONAL AND LOCAL
PLUMBING CODE REGULATIONS.
I FOR PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE
ESSENTIALLY DIAGRAMMATIC ALTHOUGH SIZE AND LOCATION OF
EQUIPMENT ARE SHOWN TO SCALE WHEREVER POSSIBLE.
J PLUMBING CONTRACTOR TO FIELD VERIFY ALL EXISTING
CONDITIONS AT THE SITE PRIOR TO PERFORMING WORK.
CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS
AFFECTING THIS SCOPE OF WORK PRIOR TO PERFORMING WORK.
K PACK SLEEVES FULL AROUND PIPES PASSING THRU FLOORS AND
FIRE-RATED WALLS AND SMOKE PARTITIONS TO MAINTAIN THE
FIRE OR SMOKE RATING OF THAT CONSTRUCTION.
L ALL PIPES SHALL BE CONCEALED IN WALLS, ABOVE CEILING AND
BELOW FLOORS. EXPOSED PIPING LOCATED ONLY AT FINAL
CONNECTIONS TO EQUIPMENT AND FIXTURES UNLESS NOTED
OTHERWISE.
M ROUTE PIPING IN EXPOSED AREAS AS HIGH AS POSSIBLE.
N REFER TO ISOMETRICS FOR PIPE SIZES NOT SHOWN IN
DRAWINGS.
O REFER TO ARCHITECTURAL DRAWING GENERAL NOTES FOR
PERTINENT INFORMATION.
P OPEN ENDS OF NEW PIPING LINES SHALL BE TEMPORARILY
CAPPED OR PLUGGED DURING CONSTRUCTION TO PREVENT
ENTRY OF DIRT OR FOREIGN MATERIALS.
Q PLUMBING CONTRACTOR TO COORDINATE ALL PLUMBING WORK
WITH TELECOMMUNICATIONS WORK (T). REFER TO "T" SERIES
DRAWINGS FOR ALL CABLE TRAY ROUTINGS AND DEVICE
LOCATION.
R THE PLUMBING CONTRACTOR SHALL COORDINATE THE ROUTING
OF ALL PIPING WITH THE LOCATIONS OF THE LIGHT FIXTURES,
STRUCTURAL, CEILING HEIGHTS, DUCTWORK, AND THE WORK OF
ALL OTHER TRADES TO AVOID CONFLICTS.
S INSTALL WATER HAMMER ARRESTORS AS INDICATED AND AS
REQUIRED BY CODE.
T COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS.
DO NOT INSTALL PIPING OVER ELECTRICAL PANELS.
U PLUMBING SYSTEMS INSTALLATION SHALL BE DESIGNED AND
INSTALLED PER IBC, IMC, AND IPC AND TO ACCOMMODATE
SEISMIC PARAMETERS, SEISMIC CATEGORY "E". PLUMBING
CONTRACTOR SHALL PROVIDE "DELEGATED DESIGN" FOR ALL
SEISMIC REQUIREMENTS.
V TRANSFORMERS, CONTROLS, AND CONTROL WIRING REQUIRED
FOR ALL PLUMBING SYSTEMS SHALL BE FURNISHED AND
INSTALLED BY THE PLUMBING CONTRACTOR.
W ALL REQUIRED CONTROL WIRING NOT SHOWN ON THE
ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE
PLUMBING WORK. WIRING IN HVAC PLENUM SPACES SHALL BE
INSTALLED ACCORDING TO CODE REQUIREMENTS.
X REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED AND
SMOKE WALL LOCATIONS.
Y ALL EQUIPMENT SHALL BE INSTALLED TO MAINTAIN ALL CODE,
MANUFACTURER, AND MAINTENANCE CLEARANCES. VERIFY
SPECIFIC LOCATION AND ORIENTATION OF EACH UNIT WITH THE
OWNER/DESIGN TEAM PRIOR TO INSTALLATION.
Z CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED
PERMITS AND INSPECTIONS.
GENERAL NOTES
(APPLIES TO ALL 'P' SERIES SHEETS)
M A
R K
D E
S C
R
IP
T
IO
N D
A
?126?
123B
123C
114 115
121C
124B
124C
121B
122B
122C
1 3 6 7 8 9 14 15 15.9
A
B
C.2
E
G
H
J
13.8
C
J.2
BB
CC
DD
EE
2 4 5
D
F
10 11 13
FF
AA
GG
4.9
A4
P-401
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
10 m
1:200
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
A
B
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -1
P-100
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
U N
D E
R G
R O
U N
D P
L U
M B
IN
G
P L
A N
O
V E
R A
L L
GENERAL SHEET NOTES
1 : 200C2
UNDERGROUND PIPING PLAN - OVERALL
ROOM SCHEDULE
Number Name
100 VESTIBULE
101 LOBBY
102 WOMEN'S R.R.
103 MEN'S R.R.
104 CHECK-IN
105 ISOLATION
106 COMMS/CCTV
107 KITCHEN
108 ELECTRICAL
109 MECHANICAL EQUIPMENT
110 STAFF CORRIDOR
111 OFFICE
112 OFFICE
113 PRINT ROOM
114 STORAGE
115 BREAK ROOM / STAFF TRAINING
120 COMMONS
121 SAC ACTIVITY ROOM
121B STORAGE
121C STORAGE
122 SAC ACTIVITY ROOM
122B STORAGE
122C STORAGE
123 SAC ACTIVITY ROOM
123B STORAGE
123C STORAGE
123D STORAGE
124 SAC ACTIVITY ROOM
124B STORAGE
124C STORAGE
125 GIRLS TOILET RM
126 JANITOR
127 BOYS TOILET RM
130 MULTI-PURPOSE ROOM
131 MULT-PURPOSE ROOM STORAGE
132 MECHANICAL EQUIPMENT
A. REFER TO SHEET P-002.
M A
R K
D E
S C
R
IP
T
IO
N D
A
WC-2WC-2
SS-1
123B
123C
WC-1
WC-1
WC-1
UR-1
WC-1
UR-1
EWC-1
SI-1
121C
124B
124C
121B
122B
122C
1 3 6 7 8 9 14 15
A
B
C.2
E
G
H
J
13.8
C
J.2
2 4 5
D
F
10 11 13
FF
GG
4.9
SK-2
L-2
L-2
L-2
L-2
L-2
L-2
SK-2
EW-1
SK-2
100 mmø SAN
100 mmø SAN m m ø
S A
N
100 mmø SAN m m ø S
A N m m ø S
A N
M
A T
C H
L
IN
E
A
P -1
M
A T
C H
L
IN
E
A
P -1
SK-2
m m ø S
A N
123D
40 mmø SAN
50 mmø SAN
100 mmø SAN
P-402
B6
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
A
B
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -1
P-101
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
U N
D E
R G
R O
U N
D P
L U
M B
IN
G
P L
A N
A
R E
A A
DRAWING NOTES
GENERAL SHEET NOTES
ROOM SCHEDULE
Number Name
100 VESTIBULE
101 LOBBY
102 WOMEN'S R.R.
103 MEN'S R.R.
104 CHECK-IN
105 ISOLATION
106 COMMS/CCTV
107 KITCHEN
108 ELECTRICAL
109 MECHANICAL EQUIPMENT
110 STAFF CORRIDOR
111 OFFICE
112 OFFICE
113 PRINT ROOM
114 STORAGE
115 BREAK ROOM / STAFF TRAINING
120 COMMONS
121 SAC ACTIVITY ROOM
121B STORAGE
121C STORAGE
122 SAC ACTIVITY ROOM
122B STORAGE
122C STORAGE
123 SAC ACTIVITY ROOM
123B STORAGE
123C STORAGE
123D STORAGE
124 SAC ACTIVITY ROOM
124B STORAGE
124C STORAGE
125 GIRLS TOILET RM
126 JANITOR
127 BOYS TOILET RM
130 MULTI-PURPOSE ROOM
131 MULT-PURPOSE ROOM STORAGE
132 MECHANICAL EQUIPMENT
1 : 100B1
UNDERGROUND PIPING PLAN - AREA A
A. REFER TO SHEET P-002.
B. COORDINATE WITH STRUCTURAL DRAWINGS FOR
PENETRATIONS THROUGH FOUNDATION SYSTEM.
M A
R K
D E
S C
R
IP
T
IO
N D
A
WC-2
REFER TO CIVIL
DRAWINGS FOR
CONTINUATION
114 115
GI-1
SP-1
15 15.9
A
C.2
E
G
J
C
J.2
BB
CC
DD
EE
FF
AA
GG
WC-2
L-1
SK-1
F M m m ø
S A
N
100 mmø SAN
100 mmø GW
SAN
m m ø S
A N m m ø
S A
N
M
A T
C H
L
IN
E
B
P -1
M
A T
C H
L
IN
E
B
P -1
REFER TO CIVIL
DRAWINGS FOR
CONTINUATION
80 mmø DCW
100 mmø SAN
P02
P02
P02
FS-1
P-403
A1
ASHP
WH-1
50 mmø DHWS
UNDERGROUND
FS-1
FS-1
FS-1
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
A
B
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -1
P-102
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
U N
D E
R G
R O
U N
D P
L U
M B
IN
G
P L
A N
A
R E
A B
DRAWING NOTES
GENERAL SHEET NOTES
ROOM SCHEDULE
Number Name
100 VESTIBULE
101 LOBBY
102 WOMEN'S R.R.
103 MEN'S R.R.
104 CHECK-IN
105 ISOLATION
106 COMMS/CCTV
107 KITCHEN
108 ELECTRICAL
109 MECHANICAL EQUIPMENT
110 STAFF CORRIDOR
111 OFFICE
112 OFFICE
113 PRINT ROOM
114 STORAGE
115 BREAK ROOM / STAFF TRAINING
120 COMMONS
121 SAC ACTIVITY ROOM
121B STORAGE
121C STORAGE
122 SAC ACTIVITY ROOM
122B STORAGE
122C STORAGE
123 SAC ACTIVITY ROOM
123B STORAGE
123C STORAGE
123D STORAGE
124 SAC ACTIVITY ROOM
124B STORAGE
124C STORAGE
125 GIRLS TOILET RM
126 JANITOR
127 BOYS TOILET RM
130 MULTI-PURPOSE ROOM
131 MULT-PURPOSE ROOM STORAGE
132 MECHANICAL EQUIPMENT
1 : 100A4
UNDERGROUND PIPING PLAN - AREA B
A. REFER TO SHEET P-002.
B. COORDINATE WITH STRUCTURAL DRAWINGS FOR
PENETRATIONS THROUGH FOUNDATION SYSTEM.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P02 TO KITCHEN EQUIPMENT PROVIDED BY FOOD
SERVICE. REFER TO "QF" SERIES DRAWINGS FOR
MORE INFORMATION.
?126?
123B
123C
114 115
121C
124B
124C
121B
122B
122C
1 3 6 7 8 9 14 15 15.9
A
B
C.2
E
G
H
J
13.8
C
J.2
BB
CC
DD
EE
2 4 5
D
F
10 11 13
FF
AA
GG
4.9
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
10 m
1:200
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
A
B
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -1
P-103
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
U N
D E
R G
R O
U N
D R
A D
O N
P L
U M
B
IN
G P
L A
N
O V
E R
A L
L
GENERAL SHEET NOTES
1 : 200C2
UNDERGROUND RADON PIPING PLAN -
OVERALL
ROOM SCHEDULE
Number Name
100 VESTIBULE
101 LOBBY
102 WOMEN'S R.R.
103 MEN'S R.R.
104 CHECK-IN
105 ISOLATION
106 COMMS/CCTV
107 KITCHEN
108 ELECTRICAL
109 MECHANICAL EQUIPMENT
110 STAFF CORRIDOR
111 OFFICE
112 OFFICE
113 PRINT ROOM
114 STORAGE
115 BREAK ROOM / STAFF TRAINING
120 COMMONS
121 SAC ACTIVITY ROOM
121B STORAGE
121C STORAGE
122 SAC ACTIVITY ROOM
122B STORAGE
122C STORAGE
123 SAC ACTIVITY ROOM
123B STORAGE
123C STORAGE
123D STORAGE
124 SAC ACTIVITY ROOM
124B STORAGE
124C STORAGE
125 GIRLS TOILET RM
126 JANITOR
127 BOYS TOILET RM
130 MULTI-PURPOSE ROOM
131 MULT-PURPOSE ROOM STORAGE
132 MECHANICAL EQUIPMENT
A. REFER TO SHEET P-002.
M A
R K
D E
S C
R
IP
T
IO
N D
A
123B
123C
121C
124B
124C
121B
122B
122C
1 3 6 7 8 9 14 15
A
B
C.2
E
G
H
J
13.8
C
J.2
2 4 5
D
F
10 11 13
FF
GG
4.9
100 mmø R
VENT UP
VENT UP
150 mmø R
R
R
R
R
R
R
R
R
R
R
R
R R
R
M
A T
C H
L
IN
E
A
P -1
M
A T
C H
L
IN
E
A
P -1
UNDERGROUND
(TYP)
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
A
B
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -1
P-104
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
U N
D E
R G
R O
U N
D R
A D
O N
P L
U M
B
IN
G P
L A
N
A R
E A
A
DRAWING NOTES
GENERAL SHEET NOTES
1 : 100B1
UNDERGROUND RADON PIPING PLAN -
AREA A
ROOM SCHEDULE
Number Name
100 VESTIBULE
101 LOBBY
102 WOMEN'S R.R.
103 MEN'S R.R.
104 CHECK-IN
105 ISOLATION
106 COMMS/CCTV
107 KITCHEN
108 ELECTRICAL
109 MECHANICAL EQUIPMENT
110 STAFF CORRIDOR
111 OFFICE
112 OFFICE
113 PRINT ROOM
114 STORAGE
115 BREAK ROOM / STAFF TRAINING
120 COMMONS
121 SAC ACTIVITY ROOM
121B STORAGE
121C STORAGE
122 SAC ACTIVITY ROOM
122B STORAGE
122C STORAGE
123 SAC ACTIVITY ROOM
123B STORAGE
123C STORAGE
123D STORAGE
124 SAC ACTIVITY ROOM
124B STORAGE
124C STORAGE
125 GIRLS TOILET RM
126 JANITOR
127 BOYS TOILET RM
130 MULTI-PURPOSE ROOM
131 MULT-PURPOSE ROOM STORAGE
132 MECHANICAL EQUIPMENT
A. REFER TO SHEET P-002.
B. COORDINATE WITH STRUCTURAL DRAWINGS FOR
PENETRATIONS THROUGH FOUNDATION SYSTEM.
M A
R K
D E
S C
R
IP
T
IO
N D
A
15 15.9
A
C.2
E
G
J
C
J.2
BB
CC
DD
EE
FF
AA
GG
VENT UP
150 mmø R
R
R
R
R
R
R
M
A T
C H
L
IN
E
B
P -1
M
A T
C H
L
IN
E
B
P -1
UNDERGROUND
(TYP)
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
A
B
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -1
P-105
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
U N
D E
R G
R O
U N
D R
A D
O N
P L
U M
B
IN
G P
L A
N
A R
E A
B
DRAWING NOTES
GENERAL SHEET NOTES
1 : 100A4
UNDERGROUND RADON PIPING PLAN -
AREA B
ROOM SCHEDULE
Number Name
100 VESTIBULE
101 LOBBY
102 WOMEN'S R.R.
103 MEN'S R.R.
104 CHECK-IN
105 ISOLATION
106 COMMS/CCTV
107 KITCHEN
108 ELECTRICAL
109 MECHANICAL EQUIPMENT
110 STAFF CORRIDOR
111 OFFICE
112 OFFICE
113 PRINT ROOM
114 STORAGE
115 BREAK ROOM / STAFF TRAINING
120 COMMONS
121 SAC ACTIVITY ROOM
121B STORAGE
121C STORAGE
122 SAC ACTIVITY ROOM
122B STORAGE
122C STORAGE
123 SAC ACTIVITY ROOM
123B STORAGE
123C STORAGE
123D STORAGE
124 SAC ACTIVITY ROOM
124B STORAGE
124C STORAGE
125 GIRLS TOILET RM
126 JANITOR
127 BOYS TOILET RM
130 MULTI-PURPOSE ROOM
131 MULT-PURPOSE ROOM STORAGE
132 MECHANICAL EQUIPMENT
A. REFER TO SHEET P-002.
B. COORDINATE WITH STRUCTURAL DRAWINGS FOR
PENETRATIONS THROUGH FOUNDATION SYSTEM.
M A
R K
D E
S C
R
IP
T
IO
N D
A
DRAFTP-401
A4
WC-2 WC-2
WC-1
UR-1
UR-1
WC-1
WC-2
SS-1
HB-1
WC-1
WC-1
EWC-1
L-1
WC-2
SI-1
?126?
123B
123C
1 3 6 7 8 9 14 15 15.9
A
B
C.2
E
G
H
J
13.8
C
J.2
BB
CC
DD
EE
2 4 5
D
F
10 11 13
FF
AA
GG
4.9
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
10 m
1:200
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
A
B
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -1
P-106
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
S T
F L
O O
R P
IP
IN
G P
L A
N
O V
E R
A L
L
DRAWING NOTES
LEGEND
GENERAL SHEET NOTES
1 : 200C2
FIRST FLOOR PIPING PLAN
ROOM SCHEDULE
Number Name
100 VESTIBULE
101 LOBBY
102 WOMEN'S R.R.
103 MEN'S R.R.
104 CHECK-IN
105 ISOLATION
106 COMMS/CCTV
107 KITCHEN
108 ELECTRICAL
109 MECHANICAL EQUIPMENT
110 STAFF CORRIDOR
111 OFFICE
112 OFFICE
113 PRINT ROOM
114 STORAGE
115 BREAK ROOM / STAFF TRAINING
120 COMMONS
121 SAC ACTIVITY ROOM
121B STORAGE
121C STORAGE
122 SAC ACTIVITY ROOM
122B STORAGE
122C STORAGE
123 SAC ACTIVITY ROOM
123B STORAGE
123C STORAGE
123D STORAGE
124 SAC ACTIVITY ROOM
124B STORAGE
124C STORAGE
125 GIRLS TOILET RM
126 JANITOR
127 BOYS TOILET RM
130 MULTI-PURPOSE ROOM
131 MULT-PURPOSE ROOM STORAGE
132 MECHANICAL EQUIPMENT
A. REFER TO SHEET P-002.
M A
R K
D E
S C
R
IP
T
IO
N D
A
WC-2 WC-2
WC-1
UR-1
UR-1
WC-1
SS-1
HB-1
WC-1
WC-1
EWC-1
SI-1
123B
123C
121C
124B
124C
121B
122B
122C
1 3 6 7 8 9 14 15
A
B
C.2
E
G
H
J
13.8
C
J.2
2 4 5
D
F
10 11 13
FF
GG
4.9
EW-1
L-2
L-2
L-2
L-2
L-2
L-2
SK-2
SK-2
SK-2
SK-2
HB-1
M
A T
C H
L
IN
E
A
P -1
M
A T
C H
L
IN
E
A
P -1
TMV-3
TMV-2 (TYP ALL SINKS)
123D
20 mmø DHWR 40 mmø DHWS
65 mmø DCW
25 mmø DCW 15 mmø DHWS
20 mmø DHWR
20 mmø DCW
32 mmø DHWS 25 mmø DCW
20 mmø DHWR
80 mmø DCW 40 mmø DHWS 20 mmø DHWR
20 mmø DCW
P01
P-402
B2
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
A
B
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -1
P-107
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
S T
F L
O O
R P
IP
IN
G P
L A
N
A R
E A
A
DRAWING NOTES
GENERAL SHEET NOTES
1 : 100B1
FIRST FLOOR PIPING PLAN - AREA A
ROOM SCHEDULE
Number Name
100 VESTIBULE
101 LOBBY
102 WOMEN'S R.R.
103 MEN'S R.R.
104 CHECK-IN
105 ISOLATION
106 COMMS/CCTV
107 KITCHEN
108 ELECTRICAL
109 MECHANICAL EQUIPMENT
110 STAFF CORRIDOR
111 OFFICE
112 OFFICE
113 PRINT ROOM
114 STORAGE
115 BREAK ROOM / STAFF TRAINING
120 COMMONS
121 SAC ACTIVITY ROOM
121B STORAGE
121C STORAGE
122 SAC ACTIVITY ROOM
122B STORAGE
122C STORAGE
123 SAC ACTIVITY ROOM
123B STORAGE
123C STORAGE
123D STORAGE
124 SAC ACTIVITY ROOM
124B STORAGE
124C STORAGE
125 GIRLS TOILET RM
126 JANITOR
127 BOYS TOILET RM
130 MULTI-PURPOSE ROOM
131 MULT-PURPOSE ROOM STORAGE
132 MECHANICAL EQUIPMENT
A. REFER TO SHEET P-002.
P01 DO NOT RUN PIPING THROUGH OR ABOVE
ELECTRICAL OR TELECOMMUNICATIONS ROOMS
UNLESS SERVING THOSE ROOMS.
M A
R K
D E
S C
R
IP
T
IO
N D
A
WC-2 L-1
WC-2
15 15.9
A
C.2
E
G
J
C
J.2
BB
CC
DD
EE
FF
AA
GG
SK-1
HB-1
M
A T
C H
L
IN
E
B
P -1
M
A T
C H
L
IN
E
B
P -1
DCW
DHWS
DHWR
D H
W R
D H
W S
D C
W
D C
W
A4
P-401
32 mmø DHWS 25 mmø DCW
20 mmø DHWR
80 mmø DCW 40 mmø DHWS 20 mmø DHWR
P01
P-403
B1
US Army Corps of Engineers ®
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
S
IZ
E
IS
O
A
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D R
A W
IN
G
C O
D E
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PLAN NORTH
5 m
1:100
SCALE
W H
V -1
-D
-0
W H
V F
H U
T Z
E L
J A
P A
N D
IS
T
R
IC
T O
K
IN
A W
A J A
P A
N
C A
M P
F O
S T
E R
O
K
IN
A W
A J A
P A
N S
C H
O O
L A
G E
C A
R E
C E
N T
E R
M
IL
C O
N P
-3
FOST
KEY PLAN
A
B
Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt
K Z
F D
E S
IG
N
B
R O
A D
W A
Y S
T C
IN
C
IN
N
A T
I, O
H
C F
Y E
C .F
Y E
S
C
A R
R O
L L
J N
A D
E R
P
S A
C
F O
S T
P lu m b in g C e n tr a l_
.r vt
M M
-D D
-Y Y
Y Y
P -1
P-108
17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)
F
IR
S T
F L
O O
R P
IP
IN
G P
L A
N
A R
E A
B
DRAWING NOTES
GENERAL SHEET NOTES
1 : 100A4
FIRST FLOOR PIPING PLAN - AREA B
ROOM SCHEDULE
Number Name
100 VESTIBULE
101 LOBBY
102 WOMEN'S R.R.
103 MEN'S R.R.
104 CHECK-IN
105 ISOLATION
106 COMMS/CCTV
107 KITCHEN
108 ELECTRICAL
109 MECHANICAL EQUIPMENT
110 STAFF CORRIDOR
111 OFFICE
112…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .