P309_SACC_FOST_Intermediate_DrawingsVOL2.pdf

PDF 27 MB Posted

Attached to
P309 Replace School Age Care Centers Camp Foster and Camp McTureous, Okinawa Japan
Solicitation number
W912HV25Z0012
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAFT

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Food Service_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

D A

N

IE

L

D A

N

IE

L

S T

A N

F O

R D P

S A

C

F O

S T

M e c h a n ic a l_

C e n tr a l_

.r vt

-0

-2

Q F

QF501

17 MARCH 2025 - 65% INTERMEDIATE DESIGN SUBMITTAL

E X

H A

U S

T H

O O

D D

E T

A

IL

S

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Food Service_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

D A

N

IE

L

D A

N

IE

L

S T

A N

F O

R D P

S A

C

F O

S T

M e c h a n ic a l_

C e n tr a l_

.r vt

-0

-2

Q F

QF502

17 MARCH 2025 - 65% INTERMEDIATE DESIGN SUBMITTAL

E X

H A

U S

T H

O O

D D

E T

A

IL

S

M A

R K

D E

S C

R

IP

T

IO

N D

A

FIRE ALARM / MASS NOTIFICATION NOTES

THE FIRE ALARM SYSTEM MUST BE DESIGNED AND INSTALLED IN

ACCORDANCE WITH NFPA 72-2022 AND SPECIFICATION SECTION 28 31 76.

ALL DEVICES AND EQUIPMENT MUST BE UL LISTED OR FM APPROVED.

DEVICE LOCATIONS AND CONDUIT ROUTING ARE CONCEPTUAL. FINAL

QUANTITY AND LAYOUT MUST BE IN ACCORDANCE WITH APPLICABLE

CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT

LISTINGS. COORDINATE LOCATIONS WITH CEILING AND BELOW FLOOR

ELECTRICAL INSTALLATION.

ALL FIRE ALARM CONDUIT MUST BE 20 MM MINIMUM. ALL CONDUIT IN

FINISHED AREAS MUST BE CONCEALED.

SYNCHRONIZE ALL VISUAL NOTIFICATION APPLIANCES. SYNCHRONIZE ALL

AUDIBLE NOTIFICATION APPLIANCES.

THE FIRE ALARM SIGNAL MUST BE BY VOICE NOTIFICATION WITH A FEMALE VOICE.

VISUAL NOTIFICATION APPLIANCES MUST BE IN ACCORDANCE WITH

NFPA 72-2022. CANDELA RATINGS SHOWN ARE THE MINIMUM RATING

AFTER DERATING IF APPLICABLE.

SIGNALING LINE CIRCUITS MUST BE CLASS B, INITIATING DEVICE CIRCUITS

MUST BE CLASS B, NOTIFICATION APPLIANCE CIRCUITS MUST BE CLASS A.

SMOKE DETECTORS MUST BE LOCATED A MINIMUM OF 914 MM FROM SUPPLY

AND RETURN AIR DIFFUSERS.

PROVIDE SIGNAGE AT THE FIRE ALARM CONTROL PANEL IDENTIFYING THE

POWER PANEL AND CIRCUIT.

TESTING MUST INCLUDE INTELLIGIBILITY MEASUREMENTS. THE CIS VALUE

MUST BE 0.80 OR HIGHER.

1.

2.

3.

4.

5.

6.

7.

8.

10.

12.

9.

PROVIDE SIGNAGE AT ALL JUNCTION BOXES CONTAINING FIRE ALARM

MODULES.

11.

CONDUCTORS MUST BE PULLED SPLICE FREE FROM DEVICE TO DEVICE,

NO T-TAPPING OF ANY CIRCUITS IS ALLOWED.

14.

ALL PENETRATIONS THROUGH FIRE RATED WALLS MUST BE FIRESTOPPED.13.

ALL FIRE ALARM DEVICES IN MULTI-PURPOSE AREA MUST HAVE

PROTECTIVE COVERS.

15.

AUTOMATIC SPRINKLER SYSTEM NOTES

2. ALL DEVICES AND EQUIPMENT MUST BE UL LISTED OR FM APPROVED.

3. AN AUTOMATIC WET PIPE SPRINKLER PROTECTION MUST BE PROVIDED THROUGHOUT THE

PROJECT, AS INDICATED.

4. DESIGN WATER SUPPLY:

STATIC PRESSURE: 441 kPa RESIDUAL PRESSURE: 135 kPa

FLOW AT RESIDUAL PRESSURE: 7,491 LPM

WATER SUPPLY INFORMATION IS BASED ON HYDRANT TEST PERFORMED BY AMERICAN

ENGINEERING CORPORATION UNDER THE REMOTE SUPERVISION OF COFFMAN ENGINEERS ON

09/16/2022.

5. THE SPRINKLER SYSTEM MUST BE HYDRAULICALLY DESIGNED USING AREA/DENSITY METHOD IN

ACCORDANCE WITH NFPA 13 AND UFC 3-600-01:

OFFICES, CORRIDORS, SAC ACTIVITY ROOMS, COMMONS:

OCCUPANCY CLASSIFICATION: LIGHT HAZARD CEILINGS UP TO 9 M

DESIGN DENSITY: 4 LPM / M2

DESIGN AREA: 140 M2

HOSE STREAM: 950 LPM

SPRINKLER TYPE: QUICK RESPONSE, MINIMUM K=80

SPRINKLER TEMPERATURE: ORDINARY

MECHANICAL, ELECTRICAL, STORAGE, KITCHEN, FIRE PUMP ROOM:

OCCUPANCY CLASSIFICATION: LIGHT HAZARD CEILINGS FROM 9 M TO 13.7 M

DESIGN DENSITY: 8.0 LPM / M2

DESIGN AREA: 230 M2

HOSE STREAM: 950 LPM

SPRINKLER TYPE: QUICK RESPONSE, MINIMUM K=115

SPRINKLER TEMPERATURE: ORDINARY / INTERMEDIATE

*INTERMEDIATE TEMPEARATURE FOR KITCHEN

MULTIPURPOSE, CEILING > 9.1 M:

OCCUPANCY CLASSIFICATION: ORDINARY HAZARD CEILINGS UP TO 9 M

DESIGN DENSITY: 8 LPM / M2

DESIGN AREA: 230 M2

HOSE STREAM: 950 LPM

SPRINKLER TYPE: QUICK RESPONSE, MINIMUM K=115

SPRINKLER TEMPERATURE: ORDINARY / INTERMEDIATE

7.

8. THE PIPE ROUTING AND SPRINKLER LOCATIONS ARE CONCEPTUAL. THE CONTRACTOR MUST

INSTALL THE SYSTEM IN ACCORDANCE WITH THE APPLICABLE CODES, MANUFACTURER'S

RECOMMENDATIONS AND EQUIPMENT LISTINGS.

PROVIDE ELECTROLESS NICKEL COATED (CORROSION RESISTANT) SPRINKLERS IN EXTERIOR

LOCATIONS.

10. ALL SPRINKLERS MUST BE APPROVED QUICK RESPONSE TYPE.

11. PROVIDE INSPECTION AND HYDROSTATIC TESTS IN ACCORDANCE WITH NFPA 13.

12. SPARE SPRINKLERS MUST BE PROVIDED IN ACCORDANCE WITH NFPA 13. HYDRAULIC DATA PLATES

MUST BE PROVIDED AT THE RISER AND ALSO ABOVE THE FIRE SPRINKLER CABINET.

SPRINKLER DESIGN MUST INCLUDE A MINIMUM 10 PERCENT SAFETY FACTOR.

13. A PRESSURE RELIEF VALVE MUST BE PROVIDED AT THE RISER, INSPECTOR'S TEST

CONNECTION AND ON THE TEST AND DRAIN VALVE AS PART OF THE FLOOR CONTROL VALVE.

1. THE SPRINKLER SYSTEM DESIGN AND INSTALLATION MUST BE IN ACCORDANCE WITH

NFPA 13-2022, AND SPECIFICATION SECTION 21 13 13. THE CONTRACTOR MUST VERIFY

THE LOCATION OF ALL SPRINKLER SYSTEM COMPONENTS AND COORDINATE WITH THE

VARIOUS TRADES. I.E. FIRE ALARM, ELECTRICAL, ETC.

6. PIPING MUST BE PROVIDED WITH EARTHQUAKE PROTECTION IN ACCORDANCE WITH NFPA 13

AND SPECIFICATION SECTION 21 13 13. PROVIDE SEISMIC BRACING AND BRANCH LINE

RESTRAINTS THROUGHOUT THE BUILDING. SEISMIC CALCULATIONS MUST BE CALCULATED

WITH A CP FACTOR 0.82. SHOP DRAWINGS MUST SHOW ZONE OF INFLUENCES FOR SEISMIC

BRACING CALCULATED.

9.

14. ALL PENETRATIONS THROUGH FIRE RATED WALLS MUST BE FIRE STOPPED.

15.

16.

PIPING MUST NOT RUN INTO COMMUNICATIONS ROOMS. PROVIDE SIDE WALL SPRINKLERS WITH

GUARDS IN THESE ROOMS.

SPRINKLER PIPING MUST COMPLY WITH NFPA 13, EXCEPT THAT COPPER AND PLASTIC PIPE

MUST NOT BE PREMITTED. ALL PIPING IN AREAS WITH A TILE CEILING MUST BE CONCEALED.

SPRINKLER HEADS LOCATED IN THE MULTI-PURPOSE MUST BE PROVIDED WITH PROTECTIVE

GUARDS.

WET CHEMICAL SUPPRESSION SYSTEM NOTES

THE KITCHEN HOOD FIRE EXTINGUISHING SYSTEM SHALL BE DESIGNED IN

ACCORDANCE WITH NFPA 17A-2024, NFPA 96-2024, PROJECT

SPECIFICATIONS, AND UFC 3-600-01.

THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL THE SUPPRESSION

SYSTEM COMPONENTS AND COORDINATE WITH THE VARIOUS TRADES, I.E.

FIRE ALARM, ELECTRICAL, ETC.

ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM APPROVED

1.

2.

3.

UPON ACTIVATION, THE SYSTEM SHALL AUTOMATICALLY SHUT ALL

SOURCES OF GAS AND ELECTRIC TO THE EQUIPMENT BELOW THE

AFFECTED HOOD.

4.

UPON ACTUATION OF THE WET CHEMICAL SUPPRESSION SYSTEM AN

AUDIBLE ALARM OR VISUAL INDICATOR SHALL SHOW SYSTEM

ACTUATED

5.

UPON ACTUATION THE WET CHEMICAL SUPPRESSION SYSTEM SHALL

ACTUATE THE FIRE ALARM SIGNALING SYSTEM IN ACCORDANCE WITH

NFPA 72-2024.

6.

FTR

LOC

FEP

DESCRIPTION

OS&Y VALVE

CHECK VALVE

SYMBOL

WET PIPE FIRE SPRINKLER RISER

FIRE ALARM TRANSCEIVER

TAMPER SWITCH

LOCAL OPERATING CONSOLE PANEL, SEE DETAIL D7/FA501

PIPE / CONDUIT BREAK FOR CONTINUATION OR CLARITY

PIPE / CONDUIT UP, AS NOTED

PIPE / CONDUIT DOWN, AS NOTED

PORTABLE FIRE EXTINGUISHER LOCATION, SURFACE MOUNTED CABINET 3A:40B:C

BOOSTER POWER SUPPLY

FLOW SWITCH

DRAIN PIPED

PORTABLE FIRE EXTINGUISHER LOCATION, SEMI-RECESSED CABINET CLASS K

K

FS FIRE SPRINKLER PIPING

WC WET CHEMICAL KITCHEN HOOD FIRE EXTINGUISHER SYSTEM

MTR FIRE ALARM MASS NOTIFICATION TRANSCEIVER (MADAHCOM)

RADIO FIRE ALARM MASS NOTIFICATION ANTENNA

FIRE DEPARTMENT CONNECTION

FIRE PROTECTION SYMBOLS AND ABBREVIATIONS

SMOKE DETECTOR, CEILING MOUNTED, PHOTOELECTRIC

MANUAL DOUBLE-ACTION PULL STATION, MOUNTED 1220 MM AFF TO TOP

ADDRESSABLE OUTPUT MODULE

ADDRESSABLE INPUT MODULE

SP SURGE PROTECTOR

DOOR HOLDERDH

PUBLIC ADDRESS RELAY MODULE

PA

RELAY

FIRE ALARM MASS NOTIFICATION CONTROL PANELFMCP

ANN ANNUNCIATOR PANEL, SEE DETAIL A1/FA501

DUCT SMOKE DETECTOR

VS

WF

PS

S

F

AIM

AOM

R

FANT

MANT

RADIO FIRE ALARM ANTENNA

S

S C

SPEAKER ONLY, WALL MOUNTED

SPEAKER ONLY, CEILING MOUNTED

C

COMBINATION SPEAKER / VISUAL DEVICE, WALL MOUNTED, XX MINIMUM CANDELA SETTING

COMBINATION SPEAKER / VISUAL DEVICE, CEILING MOUNTED, XX MINIMUM CANDELA SETTING

VISUAL ONLY, CEILING MOUNTED, XX MINIMUM CANDELA SETTING

RTS REMOTE TEST SWITCH

XX

XX

XX

WP WEATHERPROOF

TYP TYPICAL

FIRE DEPARTMENT CONNECTIONFDC

UNO UNLESS NOTED OTHERWISE

S C

MASS NOTIFICATION SPEAKER, CEILING MOUNTED

MN

SEISMIC SYSTEM NOTES:

DESIGNATED SEISMIC SYSTEMS INCLUDE THE FIRE ALARM/MASS

NOTIFICATION PANEL. DESIGNATED SEISMIC SYSTEMS MUST PROVIDE

CERTIFICATION IN ACCORDANCE WITH ASCE 7-16.

PROVIDE COMPONENT IDENTIFICATION NAMEPLATE FOR DESIGNATED

SEISMIC SYSTEMS.

SPRINKLERS MUST BE INSTALLED WITH A 25 MM ANNULAR CLEARANCE

IN ACCORDANCE WITH ASTM E580, 5.2.8.5. PROVIDE SPRINKLERS WITH

LISTED ESCUTCHEONS THAT COMPLY WITH IBC-ASCE/SEI 7

REQUIREMENTS FOR USE IN SEISMIC DESIGN CATEGORIES C, D AND E.

1.

2.

3.

FLEXIBLE SPRINKLER HOSE FITTINGS WEIGHING LESS THAN 9kg MUST

BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN

RUNNERS OR TO BE CROSS TEES THAT HAVE THE SAME CARRYING

CAPACITY AS THE MAIN RUNNERS.

4.

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

J .H

IG

A

S H

I

J .P

IL

A

R C

A

R .B

IG

T

A S

P

S A

C

F O

S T

F ir e P ro te c ti o n C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

F -0

F-001

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E P

R O

T E

C T

IO

N

N O

T E

S

S Y

M B

O L

S A

N D

A B

B R

E V

IA

T

IO

N

S

M A

R K

D E

S C

R

IP

T

IO

N D

A

DRAFTA

1 2 4 5 63

C

D

F

B

E

7 8

B.2

1A

AA

6.9

55 56 57

MULT-PURPOSE

ROOM STORAGE

MULTI-PURPOSE

ROOM

COMMONS

JANITOR

GIRLS TOILET RM

MECHANICAL

EQUIPMENT

BOYS TOILET RM

SAC ACTIVITY ROOM

STORAGE

123B

STORAGE

123C

CHECK-IN

OFFICE

MEN'S R.R.

OFFICE

KITCHEN

MECHANICAL

EQUIPMENT

WOMEN'S R.R.

PRINT ROOM

STORAGE

BREAK ROOM /

STAFF TRAINING

COMMS/CCTV

106ISOLATION

STAFF CORRIDOR

ELECTRICAL

LOBBY

SAC ACTIVITY ROOM

SAC ACTIVITY ROOM

STORAGE

121C

SAC ACTIVITY ROOM

STORAGE

124B

STORAGE

124C

STORAGE

121B

STORAGE

122B

STORAGE

122C

FA101

A1

FA102

A1

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

10 m

1:200

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

J .H

IG

A

S H

I

J .P

IL

A

R C

A

R .B

IG

T

A S

P

S A

C

F O

S T

F ir e P ro te c ti o n C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

F A

FA100

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E A

L A

R M

A

S S

N O

T

IF

IC

A

T

IO

N O

V E

R A

L L

F L

O O

R P

L A

N

1 : 2001

OVERALL FLOOR PLAN - FIRE ALARM/MASS NOTIFICATION SYSTEM

M A

R K

D E

S C

R

IP

T

IO

N D

A

F M

C P

F

F

F

F

P S

F

F

F

F

F

F T

R M

T R

F E

P F

E P

L O

C A

N N

F

F

75 75

75 75

S C

S C

S C

S C

15 15

C

C

C

C

C

C

C

C

C

C

S

C S

C C

C

C

VS

P S

/ M A

T C

H L

IN

E

A

F A

2A

1 2 4 5 63

C

D

F

B

E

7 8

B.2

1A

6.9

55 56 57

MULT-PURPOSE

ROOM STORAGE

MULTI-PURPOSE

ROOM

COMMONS

JANITOR

GIRLS TOILET RM

MECHANICAL

EQUIPMENT

BOYS TOILET RM

SAC ACTIVITY

ROOM

STORAGE

123B

STORAGE

123C

CHECK-IN

VESTIBULE

SAC ACTIVITY

ROOM

SAC ACTIVITY

ROOM

STORAGE

121C

SAC ACTIVITY

ROOM

STORAGE

124B

STORAGE

124C

STORAGE

121B

STORAGE

122B

STORAGE

122C

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

J .H

IG

A

S H

I

J .P

IL

A

R C

A

R .B

IG

T

A S

P

S A

C

F O

S T

F ir e P ro te c ti o n C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

F A

FA101

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

S Y

S T

E M

F L

O O

R P

L A

N

A R

E A

A

1 : 100A1

FIRE ALARM/MASS NOTIFICATION SYSTEM FLOOR PLAN - AREA A

M A

R K

D E

S C

R

IP

T

IO

N D

A

F

M C

P

F

P S

F

F

F

F

F

F T

R M

T R

F E

P F

E P

L O

C A

N N

F

C

C

C

C

C

MR

WC

F A

N T

MANT

C

C

C

C

C

15C

C

C

C

C

VS

P S

/ M A

T C

H L

IN

E

A

F A

A

C

D

E

7 8

B.2

1A

AA

6.9

CHECK-IN

OFFICE

MEN'S R.R.

OFFICE

KITCHEN

MECHANICAL

EQUIPMENT

WOMEN'S R.R.

PRINT ROOM

STORAGE

BREAK ROOM /

STAFF TRAINING

COMMS/CCTV

ISOLATION

STAFF CORRIDOR

ELECTRICAL

LOBBY

VESTIBULE

STORAGE

121C

STORAGE

121B

STORAGE

122B

STORAGE

122C

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

J .H

IG

A

S H

I

J .P

IL

A

R C

A

R .B

IG

T

A S

P

S A

C

F O

S T

F ir e P ro te c ti o n C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

F A

FA102

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

S Y

S T

E M

F L

O O

R P

L A

N

A R

E A

B

1 : 100A1

FIRE ALARM/MASS NOTIFICATION SYSTEM FLOOR PLAN - AREA B

FIRE ALARM NOTES

PROVIDE CONNECTION TO KITCHEN HOOD

EXTINGUISHING SYSTEM

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

MANUAL ACTIVATION STATION WET

CHEMICAL SYSTEM, HOOD 1

WET CHEMICAL EXTINGUISHING

SYSTEM, WALL MOUNTED

WET CHEMICAL SUPPRESSION SYSTEM NOTES

1. REFER TO SHEET F-001 FOR ADDITIONAL NOTES.

2. PROVIDE NEW WET CHEMICAL SUPPRESSION SYSTEM

INCLUDING, BUT NOT LIMITED TO PIPING, NOZZLES,

TANKS, DETECTION LINE, AND ACCESSORIES TO

PROTECT ASSOCIATED EXHAUST HOOD ONE IN

ACCORDANCE WITH NFPA 17A-2024, NFPA 96-2024, & THE

MANUFACTURER'S RECOMMENDATIONS.

3. CONFIRM WET CHEMICAL SUPPRESSION CYLINDER

SPACE REQUIREMENTS WITH MANUFACTURER AND FIELD

VERIFY AVAILABLE WALL SPACE TO INSTALL WET

CHEMICAL SUPPRESSION SYSTEM CYLINDERS PRIOR TO

ORDERING EQUIPMENT (TYP OF ALL HOODS).

4. PROVIDE NECESSARY EQUIPMENT TO SHUT OFF FUEL TO

ALL APPLIANCES UNDER THE EXHAUST HOOD WHEN

SYSTEM IS ACTUATED.

5. PROVIDE NEW FIRE ALARM MODULES AS NECESSARY TO

ACTIVATE THE BUILDING FIRE ALARM SYSTEM WHEN WET

CHEMICAL SYSTEM IS ACTUATED.

6. COORDINATE POWER SHUT OFF TO APPLIANCES UNDER

EXHAUST HOOD WHEN WET CHEMICAL SUPPRESSION

SYSTEM IS ACTUATED.

7. COORDINATE ALL WORK WITH MECHANICAL DWGS FOR

KITCHEN EXHAUST SYSTEM.

MOUNT FIRE ALARM AND MASS NOTIFICATION ANTENNAS

AT HIGHEST POINT ON BUILDING AND AT LEAST 6.1 M (20

FEET) FACE ANTENNA TOWARD BASE RECEIVING

STATION.

DRAFTA

1 2 4 5 63

C

D

F

B

E

7 8

B.2

1A

AA

6.9

55 56 57

MULT-PURPOSE

ROOM STORAGE

MULTI-PURPOSE

ROOM

COMMONS

JANITOR

GIRLS TOILET RM

MECHANICAL

EQUIPMENT

BOYS TOILET RM

127 SAC ACTIVITY

ROOM

STORAGE

123B

CHECK-IN

OFFICE

MEN'S R.R.

103 OFFICE

KITCHEN

MECHANICAL

EQUIPMENT

WOMEN'S R.R.

PRINT ROOM

STORAGE

BREAK ROOM /

STAFF TRAINING

COMMS/CCTV

ISOLATION

STAFF CORRIDOR

ELECTRICAL

LOBBY

VESTIBULE

SAC ACTIVITY

ROOM

SAC ACTIVITY

ROOM

STORAGE

121C

SAC ACTIVITY

ROOM

STORAGE

124B

STORAGE

124C

STORAGE

121B

STORAGE

122B

STORAGE

122C

PROVIDE AUTOMATIC WET-PIPE SPRINKLER

PROTECTION WITHIN THIS BOUNDARY

PROVIDE AUTOMATIC WET-PIPE SPRINKLER

PROTECTION WITHIN THIS BOUNDARY

FX101

A1

FX102

A1

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

10 m

1:200

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

D e s ig n e r

A u th o r

C h e c k e r

M M

-D D

-Y Y

Y Y

F X

FX100

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E S

P R

IN

K

L E

R O

V E

R A

L L

F L

O O

R P

L A

N

1 : 2001

OVERALL FLOOR PLAN - FIRE SPRINKLER

M A

R K

D E

S C

R

IP

T

IO

N D

A

FIRE SPRINKLER HAZARD

CLASSIFICATION LEGEND

DESCRIPTION

LIGHT HAZARD

SYMBOL

ORDINARY HAZARD

A

1 2 4 5 63

C

D

F

B

E

7 8

B.2

1A

6.9

55 56 57

MULT-PURPOSE

ROOM STORAGE

MULTI-PURPOSE

ROOM

COMMONS

JANITOR

GIRLS TOILET RM

MECHANICAL

EQUIPMENT

BOYS TOILET RM

SAC ACTIVITY

ROOM

STORAGE

123B

STORAGE

123C

VESTIBULE

SAC ACTIVITY

ROOM

SAC ACTIVITY

ROOM

STORAGE

121C

SAC ACTIVITY

ROOM

STORAGE

124B

STORAGE

124C

STORAGE

121B

STORAGE

122B

STORAGE

122C

PROVIDE AUTOMATIC WET-PIPE

SPRINKLER PROTECTION WITHIN

THIS BOUNDARY

M

A T

C H

L

IN

E

A

F X

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

J .H

IG

A

S H

I

J .P

IL

A

R C

A

R .B

IG

T

A S

P

S A

C

F O

S T

F ir e P ro te c ti o n C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

F X

FX101

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E S

P R

IN

K

L E

R F

L O

O R

P L

A N

A

R E

A A

1 : 100A1

FIRE SPRINKLER FLOOR PLAN - AREA A

M A

R K

D E

S C

R

IP

T

IO

N D

A

FIRE SPRINKLER HAZARD

CLASSIFICATION LEGEND

DESCRIPTION

LIGHT HAZARD

SYMBOL

ORDINARY HAZARD

A

C

D

E

7 8

B.2

1A

AA

CHECK-IN

OFFICE

MEN'S R.R.

OFFICE

KITCHEN

MECHANICAL

EQUIPMENT

WOMEN'S R.R.

PRINT ROOM

STORAGE

BREAK ROOM /

STAFF TRAINING

COMMS/CCTV

ISOLATION

STAFF CORRIDOR

ELECTRICAL

LOBBY

VESTIBULE

PROVIDE AUTOMATIC WET-

PIPE SPRINKLER

PROTECTION WITHIN THIS

BOUNDARY

M

A T

C H

L

IN

E

A

F X

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

J .H

IG

A

S H

I

J .P

IL

A

R C

A

R .B

IG

T

A S

P

S A

C

F O

S T

F ir e P ro te c ti o n C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

F X

FX102

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E S

P R

IN

K

L E

R F

L O

O R

P L

A N

A

R E

A B

1 : 100A1

FIRE SPRINKLER FLOOR PLAN - AREA B

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

WET-PIPE SPRINKLER

RISER, SEE DETAIL

D1/FX501

TOP OF DETECTOR

ACCEPTABLE HERE

DETECTOR

LOCATION

IS ACCEPTABLE

HERE

ABOVE ACCEPTABLE HEIGHT

BELOW ACCEPTABLE HEIGHT

CEILING

SIDEWALL

M

M M

A X

IM

U

M

T O

F R

O M

P E

A K

O F

R O

O F

CONC SLAB

RADIO FIRE ALARM

INTERFACE PANEL

AND TRANSMITTER

1" GALVANIZED

RIGID

CONDUIT

CONDUIT CLAMP

GRADE

TO GROUNDING

ROD AND BUILDING

GROUND

EXTERIOR WALL

ROOF

PROVIDE SUPPORT

FOR VERTICAL

PORTION OF

RACEWAY ABOVE

ROOF

LIGHTNING ARRESTOR, SEE

DETAIL "A1" THIS SHEET

PROVIDE 1"

CONDUIT SUPPORT

FOR VERTICAL

PORTION OF

RACEWAY ABOVE

ROOF

ALERT

VISUAL OR AUDIO/

VISUAL DEVICE

MANUAL FIRE

ALARM PULL

STATION

AUDIO DEVICE

M

M

M

M

M

M

M A

X

IM

U M

5'-0" MAX.

* IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR AUDIO DEVICES WHILE

LEAVING A MINIMUM OF 150 MM (6-INCHES) BETWEEN THE CEILING AND THE TOP OF THE AUDIO DEVICE, THE DEVICE MUST BE MOUNTED AT 150 MM (6-INCHES) BELOW CEILING MEASURED TO THE TOP OF THE

DEVICE.

** IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR VISUAL OR AUDIO/ VISUAL

DEVICES WHILE LEAVING A MINIMUM OF 6-INCHES BETWEEN THE CEILING AND THE TOP OF THE

VISUAL OR AUDIO/ VISUAL DEVICE, THE DEVICE MUST BE MOUNTED AT 6-INCHES BELOW CEILING

MEASURED TO THE TOP OF THE DEVICE.

1524 MM MAX.

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

D e s ig n e r

A u th o r

C h e c k e r

P

S A

C

F O

S T

F ir e P ro te c ti o n C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

F A

FA501

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

D E

T A

IL

S

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

NTS

SPRINKLER LOCATIONS FOR TILE CEILINGS

NTS

ANTENNA MOUNTING DETAIL

NTS

SPRINKLER LOCATIONS FOR TILE CEILINGS

D1

A1

D7

DRAFT ALARM - PULL STATIONS

ALARM - WATERFLOW SWITCHES, KITCHEN HOOD SYSTEM

ALARM - SMOKE DETECTORS

ALARM - PUMP RUNNING

COMMON TROUBLE

RADIO FIRE ALARM TRANSCEIVER ZONES

MASS NOTIFICATION SUPERVISORY

SUPERVISORY

PUMP TROUBLE

A C

TIV

A

TE A

U D

IO

F

IR

E A

LA

R M

S

IG

N A L

SYSTEM INPUT

A N N U N C

IA

TE S

U P

ER

V

IS

O R Y Z

O N E A

T B U

IL

D

IN

G F

M C P

A N N U N C

IA

TE

A

LA

R M

Z O N E A

T B U

IL

D

IN

G F

M C P

FIRE ALARM / MASS NOTIFICATION SYSTEM SEQUENCE OF OPERATIONS

SYSTEM OUTPUT**

A

B

C

D

E

F

H

D

EA

C

TIV

A

TE

A U D

IO

F

IR

E A

LA

R M

S

IG

N A L

MANUAL PULL STATION ACTIVATES INTO ALARM

ACTIVATION OF CEILING SMOKE DETECTOR

SPRINKLER SYSTEM TAMPER SWITCH ACTIVATES INTO ALARM

SPRINKLER SYSTEM WATERFLOW SWITCH ACTIVATES INTO ALARM

1 2 3 4 5 6 7 8 9

A N N U N C

IA

TE

T

R O U

BLE

Z O

N E A

T B U

IL

D

IN

G F

M C P

A C

TIV

A

TE V

IS

U

AL

A

LA

R M

S

TR

A N

SM

IT

S

IG

N A L

V

IA

R

AD

IO

F

IR

E A

LA

R M

S

YSTE

M

10 11 12 13 14

M U

TE S

O U N D S

YS

TEM

T H R O

U G

H O U T S

C H O O L

R

ELE

AS

E S

M O

KE

B A R R

IE

R D

O O R S

I

J

K

L

M

N

G

S H U T D

O W

N A

IR

H

AN

D

LE

R

ACTIVATION OF DUCT SMOKE DETECTOR

SYSTEM TROUBLE

ACTIVATION OF MASS NOTIFICATION SYSTEM (TRX)

ACTIVATION OF KITCHEN HOOD EXTINGUISHING SYSTEM

TROUBLE ON POWER EXTENDER PANEL

ACTIVATION OF FIRE ALARM SYSTEM (MICROPHONE)

1 2 3 4 5 6 7 8 9 10 11 12 13 14

TU

R N O

N O

C C U P A N C Y S

E N S O R L

IG

H

TIN

G C

O N

TR

O

LS

B R O

AD

C

AS

T M

AS

S N O

TIF

IC

A

TIO

N M

E

SS

AG

E IN

A D M

IN

O

FFIC

E

1 2 3 4 5 6 7 8 9 10 11 12 13 14

A C

TIV

A

TE D

O O R R

E

LE

AS

E

SPRINKLER ZONE 2-5 WATERFLOW SWITCH ACTIVATES INTO ALARM

KNOX BOX TAMPER SWITCH ACTIVATES INTO ALARM

ACTIVATION OF POLICE ALARM FROM SECURITY SYSTEM

B R O

AD

C

AS

T M

AS

S N O

TIF

IC

A

TIO

N L

O C

KD

O W

N M

E

SS

AG

E

IN

A

LL

Z O

N

ES

TROUBLE ON TWO-WAY COMMUNICATION SYSTEM

A

B

C

D

E

F

H

I

J

K

L

M

N

G

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

D e s ig n e r

A u th o r

C h e c k e r

P

S A

C

F O

S T

F ir e P ro te c ti o n C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

F A

FA601

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

S Y

S T

E M

S E

Q U

E N

C E

O F

O P

E R

A T

IO

N

D1

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

NTS

FIRE ALARM/MASS NOTIFICATION SYSTEM SEQUENCE OF OPERATIONS

12"

36"

24"24"

24"24"

12"36"

12"12"

600X600 (24" X 24") CEILING TILE

600X1200 (24" X 48") CEILING TILE

600X1200 (24" X 48") CEILING TILE

300X1200 (12" X 48") CEILING TILE

300X1200 (12" X 48") CEILING TILE

600 MM 600 MM

M

M M

M

600 MM

M

M

600 MM

300 MM

M

M

900 MM

300 MM300 MM

M

M M

M

300 MM

M

M

900 MM

M

M

CONC SLAB

ALL THREAD

ROD (TYP) *

END OF BRANCH

LINE SURGE

RETAINER CLIP

ANCHOR (TYP)

ADJUSTABLE

RING HANGER

ROD COUPLING

ROD SIZE MUST BE DETERMINED BY CALCULATIONS

WHERE L/R DOES NOT EXCEED 400

CONC SLAB

SWAY BRACE FITTINGS

SCHEDULE 40 PIPE *

PIPE CLAMP

SPRINKLER CROSSMAIN

* PIPE SIZE MUST BE DETERMINED BY CALCULATIONS

ANCHOR (TYP) CONC SLAB

SWAY BRACE FITTINGS

SCHEDULE 40 PIPE *

SPRINKLER

CROSS MAIN

ANCHOR

PIPE CLAMP

* PIPE SIZE MUST BE DETERMINED BY CALCULATIONS

AUTO SPKR

PRESSURE GAUGES

50 MM (2") DRAIN,

TERMINATE 150 MM (6")

ABOVE SPLASH BLOCK

CHECK VALVE

4 - 65 MM (2 1/2") X

100 MM (4") FIRE

DEPARTMENT

CONN.

762 MM (2'-6")

ABOVE GRADE

SPLASH BLOCK

CONCRETE THRUST BLOCK AT

BASE OF RISER 0.93 SM (10.0

SF) MINIMUM OF BEARING

SURFACE

PROVIDE 4-WAY SWAY BRACING

AT TOP AND BOTTOM OF RISER

RISER CHECK VALVE

FLEXIBLE COUPLING WITHIN 600 MM

(24") OF TOP AND BOTTOM OF THE

RISER (TYP)

DRAIN LINE (DRAIN MUST NOT BE

CONNECTED TO THE MAIN DRAIN)

OS&Y CONTROL VALVE

W/TAMPER SWITCH (TYP.)

UNDER GROUND WATER SUPPLY, SEE

CIVIL DRAWINGS FOR CONTINUATION

20 MM (3/4") STEEL TIE RODS,

BITUMASTIC COATED

25 MM (1") PRESSURE RELIEF

VALVE SET AT 1.2 MPA (175 PSI)

VS

WF

INSULATING FLANGE

PROVIDE ANNULAR CLEARANCE

IAW NFPA 13

TEST HEADER

4 - 65 MM (2 1/2") HOSE VALVES

X 100 MM (4") TEST HEADER

CONN. 762 MM (2'-6") ABOVE

GRADE

OS&Y VALVE WITH

LOCK AND CHAIN

OS&Y CONTROL VALVE

W/ CHAIN AND LOCK

NEW 200 MM (8") DOUBLE CHECK VALVE

BACKFLOW PREVENTER ASSEMBLY,

MTD IN THE VERTICAL POSITION

NOTES:

1, POLYETHYLENE, MYLAR AND PHENOLIC INSULATING SLEEVES AND

WASHERS ARE NOT ACCEPTABLE AND WILL BE REJECTED. PROVIDE

NEMA G-10 TYPE INSULATING SLEEVES AND WASHERS.

2. DOUBLE INSULATING WASHERS ARE REQURIED (ONE FOR EACH SIDE

OF EACH FLANGE ROD)

3. FULL FACE GASKETS REQUIRED. GASKET RETAINER MUST BE HIGH

COMPRESSIVE STRENGTH ASTM G-10 MATERIAL.

4. NEW GRADE 8 BOLT AND NUTS REQUIRED FOR EACH FLANGE.

5. HARDWARE QUANTITIES IN INSULATING FLANGE KIT WILL VARY

BASED ON GASKET PATTERN AND PIPE SIZE.

6. DO NOT COAT OR SPRAY INSULATING COMPONENTS WITH GREASE.

7. AFTER INSTULATING FLANGE KIT IS COMPLETELY INSTALLED, WRAP

FLANGE WITH MINIM 3 LAYERS OF PIPE JOINT TAPE WRAP.

FULL LENGTH

INSULATING SLEEVE

USE NEMA G-10

MATERIAL

STEEL WASHER (TYP)

INSULATING WASHER

ON BOTH SIDES OF

FLANGE (USE NEMA

G-10)

FLANGE NUT (TYP)

FLANGE BOLT

(TYP)

INSULATING

GASKET (NEMA

G-10 RETAINER)

BITUMASTIC

COATED TIE

RODS, SIZE IN

ACCORDANCE

WITH NFPA 13

(TYP)

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Fire Protection_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T

C

IN

C

IN

N A

T I, O

H

IO

D e s ig n e r

A u th o r

C h e c k e r

P

S A

C

F O

S T

F ir e P ro te c ti o n C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

F X

FX501

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

E S

P R

IN

K

L E

R D

E T

A

IL

S

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

NTS

SEISMIC BRACING END-HEAD (CONC)

NTS

SEISMIC BRACING LATERAL SWAY (CONC)

NTS

SEISMIC BRACING LONGITUDINAL SWAY (CONC)

NTS

WET SPRINKLER RISER DETAIL

NTS

SPRINKLER LOCATIONS FOR TILE CEILINGS

A1 A4 A7

E7

D1

NTS

DIELECTRIC INSULATING FLANGE DETAIL

D5

STANDARD PLUMBING SYMBOLS

GENERAL SYMBOLS

PLUMBING SYMBOLS

NOTES:

SANITARY WASTE STACK AND VENT NUMBER

KITCHEN EQUIPMENT/LABORATORY EQUIPMENT NUMBER

ROOF LEADER/DOWNSPOUT NUMBER

FLOOR PENETRATION LINE (ISOMETRIC)

VENT THRU ROOF (ISOMETRIC)

PIPE UP TO FIXTURE OR EQUIPMENT INDICATED

WATER ISOMETRIC NUMBER

INTERCEPTOR W/ TYPE (G=GREASE; O=OIL)

BACKWATER VALVE

BACKFLOW PREVENTER (RP=REDUCED PRESSURE;

DC=DUAL CHECK)

HUB DRAIN OUTLET W/ TRAP

FLOOR DRAIN W/ TRAP

RUNNING TRAP W/ CLEANOUT

COLD WATER

HOT WATER

HOT WATER RETURN

VENT PIPING

ROOF DRAIN

ROOF DRAIN W/ SCUPPER DRAIN

PIPING ABOVE FLOOR OR GRADE

(ABV=TYPE; SEE ABBREVIATIONS)

PIPING BELOW FLOOR OR GRADE

(ABV=TYPE; SEE ABBREVIATIONS)

FLOOR OR GRADE CLEANOUT

CATCH BASIN W/ DESIGNATION

MANHOLE W/ DESIGNATION

HOT WATER WITH HEAT TRACE

45 DEGREE DROP

PIPE ELBOW DOWN

PIPE ELBOW UP

UNION

THERMOMETER WELL

CONCENTRIC REDUCER

ECCENTRIC REDUCER

FLEXIBLE CONNECTION

PLUG VALVE

O.S. & Y VALVE

QUICK OPENING VALVE

PIPE TEE DOWN

PIPE TEE UP

BLOW-OFF STRAINER

ABBREVIATION OF PIPE CONTENTS

AUTOMATIC FLOW CONTROL VALVE

AUTOMATIC AIR VENT

PUMP

ABBREVIATION OF ITEM

THERMOMETER

PRESSURE GAGE & COCK

MANUAL AIR VENT

(SELF CONTAINED)

TRAP, STEAM W/ TYPE (F & T = FLOAT &

THERMOSTAT; BT = BUCKET, TT = THERMOSTATIC)

PIPE CAP

ALIGNMENT GUIDE (A = TYPE)

ANCHOR (A =TYPE)

EXPANSION JOINT (A = TYPE)

EXPANSION LOOP

FLEXIBLE CONNECTOR

PITCH OF PIPE (R = RISE; D = DROP)

IN DIRECTION OF FLOW

PUMP SUCTION DIFFUSER

PRESSURE/TEMPERATURE PORT

BALL VALVE

BUTTERFLY VALVE

GATE VALVE

GLOBE VALVE

RELIEF VALVE

BALANCING VALVE

PRESSURE REDUCING VALVE

CHECK VALVE

CALIBRATED BALANCING VALVE

CHECK VALVE W/BALL DRIP

GATE ANGLE VALVE

GLOBE ANGLE VALVE

STRAINER

A THIS LEGEND IS COMPOSED OF STANDARD SYMBOLS

AND APPLIES TO THE SET OF DRAWINGS TO THE EXTENT

APPLICABLE.

DETAIL OR SECTION BUBBLE

USE "LETTERS" FOR SECTIONS

USE "NUMBERS" FOR DETAILS

EQUIPMENT MARK NUMBER

SHEET NUMBER WHERE SECTION/DETAIL IS SHOWN

ABBREVIATION OF ITEM

G

X

AHU-1

A

M3

ABV.

R2

S1

(ABV)

(ABV)

CB-1

MH-1

AAV

MAV

TW

ABV.

A

A

A

ABV

F & T

R

PSD

DRAWING NOTE HEX

CONNECT TO EXISTING

DETAIL OUTLINE

PIPING SYMBOLS

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -0

P-001

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

A B

B R

E V

IA

T

IO

N

S A

N D

G E

N E

R A

L N

O T

E S

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

ASHP AIR SOURCE HEAT PUMP

BFP BACKFLOW PREVENTER

BP BOOSTER PUMP

BR BRINE TANK

C CENTIGRADE TEMPERATURE

CO CLEAN OUT

CP CIRCULATING PUMP

DCW DOMESTIC COLD WATER

DFU DRAINAGE FIXTURE UNITS

DHWR DOMESTIC HOT WATER RETURN

DHWS DOMESTIC HOT WATER SUPPLY

DIA DIAMETER

DWG DRAWING

EL or ELEV ELEVATION

ET EXPANSION TANK

EW EMERGENCY EYE/FACE WASH

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FPWH FREEZEPROOF WALL HYDRANT

FS FLOOR SINK

GCO GRADE CLEANOUT

GI GREASE INTERCEPTOR

GW GREASE WASTE SEWER

GWH GAS WATER HEATER

HB HOSE BIBB

HP HORSEPOWER

HZ HERTZ

KG KILOGRAM

KW KILOWATT

KWH KILOWATT-HOUR

L**** LAVATORY

L**** LITERS

LPS LITERS PER SECOND

M METERS

MAX MAXIMUM

MCA MINIMUM CIRCUIT AMPS

MG MILLIGRAMS

MIN MINIMUM

MM MILIMETERS

MOCP MINIMUM OVERCURRENT PROTECTION

MS MOP SINK

NTS NOT TO SCALE

P PUMP

PH PHASE

PPM PARTS PER MILLION

R RADON

RCP RECIRCULATING PUMP

RPM REVOLUTIONS PER MINUTE

S SECOND(S)

SAN SANITARY SEWER

SF SOFTENER

SH SHOWER

SI SOLIDS INTERCEPTOR

SK SINK

SS SERVICE SINK

ST STORAGE TANK

TMV THERMOSTATIC MIXING VALVE

TYP TYPICAL

PLUMBING ABBREVIATIONS

UG UNDERGROUND

UR URINAL

V**** VENT

V**** VOLT

VTR VENT THROUGH ROOF

W WATTS

WC WATER CLOSET

WCO WALL CLEANOUT

WH WALL HYDRANT

WHA WATER HAMMER ARRESTOR

M A

R K

D E

S C

R

IP

T

IO

N D

A of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -0

P-002

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

G E

N E

R A

L N

O T

E S

A ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH

INTERNATIONAL PLUMBING CODE, JAPAN DISTRICT DESIGN

GUIDE, AND ALL APPLICABLE UFC'S, LOCAL PLUMBING CODES

AND ORDINANCES.

B TOPS OF ALL FLOOR DRAINS AND CLEANOUTS SHALL BE SET

FLUSH WITH FINISHED FLOOR.

C ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED BY

THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING

TILES OR CEILING STRUCTURE.

D THE PLUMBING CONTRACTORS AND EQUIPMENT SUPPLIERS

SHALL COMPARE THE ELECTRICAL POWER REQUIREMENTS OF

THE INTENDED AS SPECIFIED WITH THE POWER

CHARACTERISTICS TO THE EQUIPMENT AS SHOWN ON THE

ELECTRICAL DRAWINGS. SHOULD THE SELECTED EQUIPMENT AS

FURNISHED BY THE CONTRACTOR REQUIRE A LARGER REVISION

OF ITS BRANCH FEEDER, THE ADDED COSTS SHALL BE BORNE BY

THE CONTRACTOR FURNISHING THE EQUIPMENT.

E ALL PLUMBING EQUIPMENT SHALL BE INSTALLED ACCORDING TO

MANUFACTURER'S RECOMMENDATIONS.

F ALL PLUMBING EQUIPMENT, PIPING INSULATION, ETC. INSTALLED

IN HVAC PLENUM SPACES SHALL MEET CODE REQUIREMENTS

FOR SMOKING AND COMBUSTIBILITY.

G ALL HORIZONTAL STORM, SOIL AND WASTE PIPING SHALL BE

SLOPED PER INTERNATIONAL PLUMBING CODE (IPC) AND MUST

BE PROVIDED WITH A MINIMUM SLOPE GREATER THAN 1% PER

UFC 3-420-01.

H FURNISH ALL MATERIALS, EQUIPMENT AND INSTRUMENTS

NECESSARY TO CONDUCT ALL TESTING OF PLUMBING PIPING

SYSTEMS IN ACCORDANCE WITH THE INTERNATIONAL AND LOCAL

PLUMBING CODE REGULATIONS.

I FOR PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE

ESSENTIALLY DIAGRAMMATIC ALTHOUGH SIZE AND LOCATION OF

EQUIPMENT ARE SHOWN TO SCALE WHEREVER POSSIBLE.

J PLUMBING CONTRACTOR TO FIELD VERIFY ALL EXISTING

CONDITIONS AT THE SITE PRIOR TO PERFORMING WORK.

CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS

AFFECTING THIS SCOPE OF WORK PRIOR TO PERFORMING WORK.

K PACK SLEEVES FULL AROUND PIPES PASSING THRU FLOORS AND

FIRE-RATED WALLS AND SMOKE PARTITIONS TO MAINTAIN THE

FIRE OR SMOKE RATING OF THAT CONSTRUCTION.

L ALL PIPES SHALL BE CONCEALED IN WALLS, ABOVE CEILING AND

BELOW FLOORS. EXPOSED PIPING LOCATED ONLY AT FINAL

CONNECTIONS TO EQUIPMENT AND FIXTURES UNLESS NOTED

OTHERWISE.

M ROUTE PIPING IN EXPOSED AREAS AS HIGH AS POSSIBLE.

N REFER TO ISOMETRICS FOR PIPE SIZES NOT SHOWN IN

DRAWINGS.

O REFER TO ARCHITECTURAL DRAWING GENERAL NOTES FOR

PERTINENT INFORMATION.

P OPEN ENDS OF NEW PIPING LINES SHALL BE TEMPORARILY

CAPPED OR PLUGGED DURING CONSTRUCTION TO PREVENT

ENTRY OF DIRT OR FOREIGN MATERIALS.

Q PLUMBING CONTRACTOR TO COORDINATE ALL PLUMBING WORK

WITH TELECOMMUNICATIONS WORK (T). REFER TO "T" SERIES

DRAWINGS FOR ALL CABLE TRAY ROUTINGS AND DEVICE

LOCATION.

R THE PLUMBING CONTRACTOR SHALL COORDINATE THE ROUTING

OF ALL PIPING WITH THE LOCATIONS OF THE LIGHT FIXTURES,

STRUCTURAL, CEILING HEIGHTS, DUCTWORK, AND THE WORK OF

ALL OTHER TRADES TO AVOID CONFLICTS.

S INSTALL WATER HAMMER ARRESTORS AS INDICATED AND AS

REQUIRED BY CODE.

T COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS.

DO NOT INSTALL PIPING OVER ELECTRICAL PANELS.

U PLUMBING SYSTEMS INSTALLATION SHALL BE DESIGNED AND

INSTALLED PER IBC, IMC, AND IPC AND TO ACCOMMODATE

SEISMIC PARAMETERS, SEISMIC CATEGORY "E". PLUMBING

CONTRACTOR SHALL PROVIDE "DELEGATED DESIGN" FOR ALL

SEISMIC REQUIREMENTS.

V TRANSFORMERS, CONTROLS, AND CONTROL WIRING REQUIRED

FOR ALL PLUMBING SYSTEMS SHALL BE FURNISHED AND

INSTALLED BY THE PLUMBING CONTRACTOR.

W ALL REQUIRED CONTROL WIRING NOT SHOWN ON THE

ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE

PLUMBING WORK. WIRING IN HVAC PLENUM SPACES SHALL BE

INSTALLED ACCORDING TO CODE REQUIREMENTS.

X REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED AND

SMOKE WALL LOCATIONS.

Y ALL EQUIPMENT SHALL BE INSTALLED TO MAINTAIN ALL CODE,

MANUFACTURER, AND MAINTENANCE CLEARANCES. VERIFY

SPECIFIC LOCATION AND ORIENTATION OF EACH UNIT WITH THE

OWNER/DESIGN TEAM PRIOR TO INSTALLATION.

Z CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED

PERMITS AND INSPECTIONS.

GENERAL NOTES

(APPLIES TO ALL 'P' SERIES SHEETS)

M A

R K

D E

S C

R

IP

T

IO

N D

A

?126?

123B

123C

114 115

121C

124B

124C

121B

122B

122C

1 3 6 7 8 9 14 15 15.9

A

B

C.2

E

G

H

J

13.8

C

J.2

BB

CC

DD

EE

2 4 5

D

F

10 11 13

FF

AA

GG

4.9

A4

P-401

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

10 m

1:200

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

A

B

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -1

P-100

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

U N

D E

R G

R O

U N

D P

L U

M B

IN

G

P L

A N

O

V E

R A

L L

GENERAL SHEET NOTES

1 : 200C2

UNDERGROUND PIPING PLAN - OVERALL

ROOM SCHEDULE

Number Name

100 VESTIBULE

101 LOBBY

102 WOMEN'S R.R.

103 MEN'S R.R.

104 CHECK-IN

105 ISOLATION

106 COMMS/CCTV

107 KITCHEN

108 ELECTRICAL

109 MECHANICAL EQUIPMENT

110 STAFF CORRIDOR

111 OFFICE

112 OFFICE

113 PRINT ROOM

114 STORAGE

115 BREAK ROOM / STAFF TRAINING

120 COMMONS

121 SAC ACTIVITY ROOM

121B STORAGE

121C STORAGE

122 SAC ACTIVITY ROOM

122B STORAGE

122C STORAGE

123 SAC ACTIVITY ROOM

123B STORAGE

123C STORAGE

123D STORAGE

124 SAC ACTIVITY ROOM

124B STORAGE

124C STORAGE

125 GIRLS TOILET RM

126 JANITOR

127 BOYS TOILET RM

130 MULTI-PURPOSE ROOM

131 MULT-PURPOSE ROOM STORAGE

132 MECHANICAL EQUIPMENT

A. REFER TO SHEET P-002.

M A

R K

D E

S C

R

IP

T

IO

N D

A

WC-2WC-2

SS-1

123B

123C

WC-1

WC-1

WC-1

UR-1

WC-1

UR-1

EWC-1

SI-1

121C

124B

124C

121B

122B

122C

1 3 6 7 8 9 14 15

A

B

C.2

E

G

H

J

13.8

C

J.2

2 4 5

D

F

10 11 13

FF

GG

4.9

SK-2

L-2

L-2

L-2

L-2

L-2

L-2

SK-2

EW-1

SK-2

100 mmø SAN

100 mmø SAN m m ø

S A

N

100 mmø SAN m m ø S

A N m m ø S

A N

M

A T

C H

L

IN

E

A

P -1

M

A T

C H

L

IN

E

A

P -1

SK-2

m m ø S

A N

123D

40 mmø SAN

50 mmø SAN

100 mmø SAN

P-402

B6

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

A

B

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -1

P-101

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

U N

D E

R G

R O

U N

D P

L U

M B

IN

G

P L

A N

A

R E

A A

DRAWING NOTES

GENERAL SHEET NOTES

ROOM SCHEDULE

Number Name

100 VESTIBULE

101 LOBBY

102 WOMEN'S R.R.

103 MEN'S R.R.

104 CHECK-IN

105 ISOLATION

106 COMMS/CCTV

107 KITCHEN

108 ELECTRICAL

109 MECHANICAL EQUIPMENT

110 STAFF CORRIDOR

111 OFFICE

112 OFFICE

113 PRINT ROOM

114 STORAGE

115 BREAK ROOM / STAFF TRAINING

120 COMMONS

121 SAC ACTIVITY ROOM

121B STORAGE

121C STORAGE

122 SAC ACTIVITY ROOM

122B STORAGE

122C STORAGE

123 SAC ACTIVITY ROOM

123B STORAGE

123C STORAGE

123D STORAGE

124 SAC ACTIVITY ROOM

124B STORAGE

124C STORAGE

125 GIRLS TOILET RM

126 JANITOR

127 BOYS TOILET RM

130 MULTI-PURPOSE ROOM

131 MULT-PURPOSE ROOM STORAGE

132 MECHANICAL EQUIPMENT

1 : 100B1

UNDERGROUND PIPING PLAN - AREA A

A. REFER TO SHEET P-002.

B. COORDINATE WITH STRUCTURAL DRAWINGS FOR

PENETRATIONS THROUGH FOUNDATION SYSTEM.

M A

R K

D E

S C

R

IP

T

IO

N D

A

WC-2

REFER TO CIVIL

DRAWINGS FOR

CONTINUATION

114 115

GI-1

SP-1

15 15.9

A

C.2

E

G

J

C

J.2

BB

CC

DD

EE

FF

AA

GG

WC-2

L-1

SK-1

F M m m ø

S A

N

100 mmø SAN

100 mmø GW

SAN

m m ø S

A N m m ø

S A

N

M

A T

C H

L

IN

E

B

P -1

M

A T

C H

L

IN

E

B

P -1

REFER TO CIVIL

DRAWINGS FOR

CONTINUATION

80 mmø DCW

100 mmø SAN

P02

P02

P02

FS-1

P-403

A1

ASHP

WH-1

50 mmø DHWS

UNDERGROUND

FS-1

FS-1

FS-1

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

A

B

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -1

P-102

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

U N

D E

R G

R O

U N

D P

L U

M B

IN

G

P L

A N

A

R E

A B

DRAWING NOTES

GENERAL SHEET NOTES

ROOM SCHEDULE

Number Name

100 VESTIBULE

101 LOBBY

102 WOMEN'S R.R.

103 MEN'S R.R.

104 CHECK-IN

105 ISOLATION

106 COMMS/CCTV

107 KITCHEN

108 ELECTRICAL

109 MECHANICAL EQUIPMENT

110 STAFF CORRIDOR

111 OFFICE

112 OFFICE

113 PRINT ROOM

114 STORAGE

115 BREAK ROOM / STAFF TRAINING

120 COMMONS

121 SAC ACTIVITY ROOM

121B STORAGE

121C STORAGE

122 SAC ACTIVITY ROOM

122B STORAGE

122C STORAGE

123 SAC ACTIVITY ROOM

123B STORAGE

123C STORAGE

123D STORAGE

124 SAC ACTIVITY ROOM

124B STORAGE

124C STORAGE

125 GIRLS TOILET RM

126 JANITOR

127 BOYS TOILET RM

130 MULTI-PURPOSE ROOM

131 MULT-PURPOSE ROOM STORAGE

132 MECHANICAL EQUIPMENT

1 : 100A4

UNDERGROUND PIPING PLAN - AREA B

A. REFER TO SHEET P-002.

B. COORDINATE WITH STRUCTURAL DRAWINGS FOR

PENETRATIONS THROUGH FOUNDATION SYSTEM.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

P02 TO KITCHEN EQUIPMENT PROVIDED BY FOOD

SERVICE. REFER TO "QF" SERIES DRAWINGS FOR

MORE INFORMATION.

?126?

123B

123C

114 115

121C

124B

124C

121B

122B

122C

1 3 6 7 8 9 14 15 15.9

A

B

C.2

E

G

H

J

13.8

C

J.2

BB

CC

DD

EE

2 4 5

D

F

10 11 13

FF

AA

GG

4.9

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

10 m

1:200

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

A

B

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -1

P-103

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

U N

D E

R G

R O

U N

D R

A D

O N

P L

U M

B

IN

G P

L A

N

O V

E R

A L

L

GENERAL SHEET NOTES

1 : 200C2

UNDERGROUND RADON PIPING PLAN -

OVERALL

ROOM SCHEDULE

Number Name

100 VESTIBULE

101 LOBBY

102 WOMEN'S R.R.

103 MEN'S R.R.

104 CHECK-IN

105 ISOLATION

106 COMMS/CCTV

107 KITCHEN

108 ELECTRICAL

109 MECHANICAL EQUIPMENT

110 STAFF CORRIDOR

111 OFFICE

112 OFFICE

113 PRINT ROOM

114 STORAGE

115 BREAK ROOM / STAFF TRAINING

120 COMMONS

121 SAC ACTIVITY ROOM

121B STORAGE

121C STORAGE

122 SAC ACTIVITY ROOM

122B STORAGE

122C STORAGE

123 SAC ACTIVITY ROOM

123B STORAGE

123C STORAGE

123D STORAGE

124 SAC ACTIVITY ROOM

124B STORAGE

124C STORAGE

125 GIRLS TOILET RM

126 JANITOR

127 BOYS TOILET RM

130 MULTI-PURPOSE ROOM

131 MULT-PURPOSE ROOM STORAGE

132 MECHANICAL EQUIPMENT

A. REFER TO SHEET P-002.

M A

R K

D E

S C

R

IP

T

IO

N D

A

123B

123C

121C

124B

124C

121B

122B

122C

1 3 6 7 8 9 14 15

A

B

C.2

E

G

H

J

13.8

C

J.2

2 4 5

D

F

10 11 13

FF

GG

4.9

100 mmø R

VENT UP

VENT UP

150 mmø R

R

R

R

R

R

R

R

R

R

R

R

R R

R

M

A T

C H

L

IN

E

A

P -1

M

A T

C H

L

IN

E

A

P -1

UNDERGROUND

(TYP)

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

A

B

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -1

P-104

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

U N

D E

R G

R O

U N

D R

A D

O N

P L

U M

B

IN

G P

L A

N

A R

E A

A

DRAWING NOTES

GENERAL SHEET NOTES

1 : 100B1

UNDERGROUND RADON PIPING PLAN -

AREA A

ROOM SCHEDULE

Number Name

100 VESTIBULE

101 LOBBY

102 WOMEN'S R.R.

103 MEN'S R.R.

104 CHECK-IN

105 ISOLATION

106 COMMS/CCTV

107 KITCHEN

108 ELECTRICAL

109 MECHANICAL EQUIPMENT

110 STAFF CORRIDOR

111 OFFICE

112 OFFICE

113 PRINT ROOM

114 STORAGE

115 BREAK ROOM / STAFF TRAINING

120 COMMONS

121 SAC ACTIVITY ROOM

121B STORAGE

121C STORAGE

122 SAC ACTIVITY ROOM

122B STORAGE

122C STORAGE

123 SAC ACTIVITY ROOM

123B STORAGE

123C STORAGE

123D STORAGE

124 SAC ACTIVITY ROOM

124B STORAGE

124C STORAGE

125 GIRLS TOILET RM

126 JANITOR

127 BOYS TOILET RM

130 MULTI-PURPOSE ROOM

131 MULT-PURPOSE ROOM STORAGE

132 MECHANICAL EQUIPMENT

A. REFER TO SHEET P-002.

B. COORDINATE WITH STRUCTURAL DRAWINGS FOR

PENETRATIONS THROUGH FOUNDATION SYSTEM.

M A

R K

D E

S C

R

IP

T

IO

N D

A

15 15.9

A

C.2

E

G

J

C

J.2

BB

CC

DD

EE

FF

AA

GG

VENT UP

150 mmø R

R

R

R

R

R

R

M

A T

C H

L

IN

E

B

P -1

M

A T

C H

L

IN

E

B

P -1

UNDERGROUND

(TYP)

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

A

B

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -1

P-105

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

U N

D E

R G

R O

U N

D R

A D

O N

P L

U M

B

IN

G P

L A

N

A R

E A

B

DRAWING NOTES

GENERAL SHEET NOTES

1 : 100A4

UNDERGROUND RADON PIPING PLAN -

AREA B

ROOM SCHEDULE

Number Name

100 VESTIBULE

101 LOBBY

102 WOMEN'S R.R.

103 MEN'S R.R.

104 CHECK-IN

105 ISOLATION

106 COMMS/CCTV

107 KITCHEN

108 ELECTRICAL

109 MECHANICAL EQUIPMENT

110 STAFF CORRIDOR

111 OFFICE

112 OFFICE

113 PRINT ROOM

114 STORAGE

115 BREAK ROOM / STAFF TRAINING

120 COMMONS

121 SAC ACTIVITY ROOM

121B STORAGE

121C STORAGE

122 SAC ACTIVITY ROOM

122B STORAGE

122C STORAGE

123 SAC ACTIVITY ROOM

123B STORAGE

123C STORAGE

123D STORAGE

124 SAC ACTIVITY ROOM

124B STORAGE

124C STORAGE

125 GIRLS TOILET RM

126 JANITOR

127 BOYS TOILET RM

130 MULTI-PURPOSE ROOM

131 MULT-PURPOSE ROOM STORAGE

132 MECHANICAL EQUIPMENT

A. REFER TO SHEET P-002.

B. COORDINATE WITH STRUCTURAL DRAWINGS FOR

PENETRATIONS THROUGH FOUNDATION SYSTEM.

M A

R K

D E

S C

R

IP

T

IO

N D

A

DRAFTP-401

A4

WC-2 WC-2

WC-1

UR-1

UR-1

WC-1

WC-2

SS-1

HB-1

WC-1

WC-1

EWC-1

L-1

WC-2

SI-1

?126?

123B

123C

1 3 6 7 8 9 14 15 15.9

A

B

C.2

E

G

H

J

13.8

C

J.2

BB

CC

DD

EE

2 4 5

D

F

10 11 13

FF

AA

GG

4.9

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

10 m

1:200

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

A

B

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -1

P-106

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

S T

F L

O O

R P

IP

IN

G P

L A

N

O V

E R

A L

L

DRAWING NOTES

LEGEND

GENERAL SHEET NOTES

1 : 200C2

FIRST FLOOR PIPING PLAN

ROOM SCHEDULE

Number Name

100 VESTIBULE

101 LOBBY

102 WOMEN'S R.R.

103 MEN'S R.R.

104 CHECK-IN

105 ISOLATION

106 COMMS/CCTV

107 KITCHEN

108 ELECTRICAL

109 MECHANICAL EQUIPMENT

110 STAFF CORRIDOR

111 OFFICE

112 OFFICE

113 PRINT ROOM

114 STORAGE

115 BREAK ROOM / STAFF TRAINING

120 COMMONS

121 SAC ACTIVITY ROOM

121B STORAGE

121C STORAGE

122 SAC ACTIVITY ROOM

122B STORAGE

122C STORAGE

123 SAC ACTIVITY ROOM

123B STORAGE

123C STORAGE

123D STORAGE

124 SAC ACTIVITY ROOM

124B STORAGE

124C STORAGE

125 GIRLS TOILET RM

126 JANITOR

127 BOYS TOILET RM

130 MULTI-PURPOSE ROOM

131 MULT-PURPOSE ROOM STORAGE

132 MECHANICAL EQUIPMENT

A. REFER TO SHEET P-002.

M A

R K

D E

S C

R

IP

T

IO

N D

A

WC-2 WC-2

WC-1

UR-1

UR-1

WC-1

SS-1

HB-1

WC-1

WC-1

EWC-1

SI-1

123B

123C

121C

124B

124C

121B

122B

122C

1 3 6 7 8 9 14 15

A

B

C.2

E

G

H

J

13.8

C

J.2

2 4 5

D

F

10 11 13

FF

GG

4.9

EW-1

L-2

L-2

L-2

L-2

L-2

L-2

SK-2

SK-2

SK-2

SK-2

HB-1

M

A T

C H

L

IN

E

A

P -1

M

A T

C H

L

IN

E

A

P -1

TMV-3

TMV-2 (TYP ALL SINKS)

123D

20 mmø DHWR 40 mmø DHWS

65 mmø DCW

25 mmø DCW 15 mmø DHWS

20 mmø DHWR

20 mmø DCW

32 mmø DHWS 25 mmø DCW

20 mmø DHWR

80 mmø DCW 40 mmø DHWS 20 mmø DHWR

20 mmø DCW

P01

P-402

B2

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

A

B

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -1

P-107

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

S T

F L

O O

R P

IP

IN

G P

L A

N

A R

E A

A

DRAWING NOTES

GENERAL SHEET NOTES

1 : 100B1

FIRST FLOOR PIPING PLAN - AREA A

ROOM SCHEDULE

Number Name

100 VESTIBULE

101 LOBBY

102 WOMEN'S R.R.

103 MEN'S R.R.

104 CHECK-IN

105 ISOLATION

106 COMMS/CCTV

107 KITCHEN

108 ELECTRICAL

109 MECHANICAL EQUIPMENT

110 STAFF CORRIDOR

111 OFFICE

112 OFFICE

113 PRINT ROOM

114 STORAGE

115 BREAK ROOM / STAFF TRAINING

120 COMMONS

121 SAC ACTIVITY ROOM

121B STORAGE

121C STORAGE

122 SAC ACTIVITY ROOM

122B STORAGE

122C STORAGE

123 SAC ACTIVITY ROOM

123B STORAGE

123C STORAGE

123D STORAGE

124 SAC ACTIVITY ROOM

124B STORAGE

124C STORAGE

125 GIRLS TOILET RM

126 JANITOR

127 BOYS TOILET RM

130 MULTI-PURPOSE ROOM

131 MULT-PURPOSE ROOM STORAGE

132 MECHANICAL EQUIPMENT

A. REFER TO SHEET P-002.

P01 DO NOT RUN PIPING THROUGH OR ABOVE

ELECTRICAL OR TELECOMMUNICATIONS ROOMS

UNLESS SERVING THOSE ROOMS.

M A

R K

D E

S C

R

IP

T

IO

N D

A

WC-2 L-1

WC-2

15 15.9

A

C.2

E

G

J

C

J.2

BB

CC

DD

EE

FF

AA

GG

SK-1

HB-1

M

A T

C H

L

IN

E

B

P -1

M

A T

C H

L

IN

E

B

P -1

DCW

DHWS

DHWR

D H

W R

D H

W S

D C

W

D C

W

A4

P-401

32 mmø DHWS 25 mmø DCW

20 mmø DHWR

80 mmø DCW 40 mmø DHWS 20 mmø DHWR

P01

P-403

B1

US Army Corps of Engineers ®

1 2 3 4 5 6 7 8 9 10

A

B

C

D

E

F

G

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

S

IZ

E

IS

O

A

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D R

A W

IN

G

C O

D E

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

PLAN NORTH

5 m

1:100

SCALE

W H

V -1

-D

-0

W H

V F

H U

T Z

E L

J A

P A

N D

IS

T

R

IC

T O

K

IN

A W

A J A

P A

N

C A

M P

F O

S T

E R

O

K

IN

A W

A J A

P A

N S

C H

O O

L A

G E

C A

R E

C E

N T

E R

M

IL

C O

N P

-3

FOST

KEY PLAN

A

B

Autodesk Docs://Japan School Age Care Centers/P309_SAC_FOST_Plumbing_Central_2022.rvt

K Z

F D

E S

IG

N

B

R O

A D

W A

Y S

T C

IN

C

IN

N

A T

I, O

H

C F

Y E

C .F

Y E

S

C

A R

R O

L L

J N

A D

E R

P

S A

C

F O

S T

P lu m b in g C e n tr a l_

.r vt

M M

-D D

-Y Y

Y Y

P -1

P-108

17 MARCH 2025 - INTERMEDIATE SUBMITTAL (65%)

F

IR

S T

F L

O O

R P

IP

IN

G P

L A

N

A R

E A

B

DRAWING NOTES

GENERAL SHEET NOTES

1 : 100A4

FIRST FLOOR PIPING PLAN - AREA B

ROOM SCHEDULE

Number Name

100 VESTIBULE

101 LOBBY

102 WOMEN'S R.R.

103 MEN'S R.R.

104 CHECK-IN

105 ISOLATION

106 COMMS/CCTV

107 KITCHEN

108 ELECTRICAL

109 MECHANICAL EQUIPMENT

110 STAFF CORRIDOR

111 OFFICE

112…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .