DRAWING INDEX
SCALE: NONE
KEY PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
T100
COVER SHEET
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRM DESIGN & PLANNING LLC
448 DELAWARE AVE.
SUITE 202
BUFFALO, NEW YORK 14202
P:716.946.9092
M/E/P:
C&S COMPANIES
150 STATE STREET
SUITE 120
ROCHESTER, NEW YORK 14614
P:585.325.9040
BATH VA MEDICAL CENTER
76 VETERANS AVE.
BATH,NY 14810
528-A6-18-616
B-24
08/01/2018 RAD GLG-AS-CCCRevisions: Date:
COR-STEPHEN WIGHTMAN NOTE:
o n e e ig h th in ch o n e f o o t th re e in ch e s o n e f o o t o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t o n e q u a rt e r in ch o n e f o o t
FINAL RENOVATE BATHROOMS,
B-24 AT BATH VAMC
SCALE: NONE
VAMC BATH CAMPUS LOCATION MAP
60% REVIEW PHASE 9/7/18
90% REVIEW PHASE 10/9/18
FINAL 11/26/18
R
RENOVATE BATHROOMS,
DEPARTMENT OF VETERANS AFFAIRS
PROJECT NO. 528-A6-18-616
BUILDING #24
BATH, NY
B-24 AT BATH VAMC
LOBBY
DINING ROOM
SEE DWG. E-49
(3)4"C
(1)4"C.,(2)1 1/2"FD
TO BUILDING 104
SEE NOTE 2
30" X 36" X 12"
PULL BOX
ELECT. CLOS.
24 SF
P1 V72
95 SF
D49, D50
OFFICE
81SF
1SW2
V49, V50
D N
105C
41 SF
E.M.S.
C
C O R R
ID
O R
D47, D48 V47, V4824
93 SF
STORAGE
256 SF
CLINICAL
DIETITIAN
D45, D46 V45, V46
349 SF
4"C
V43, V44
D43, D44N&FS
OFFICE
D41, D42 V41, V42
196 SF
OFFICE
S F
H A
C
CLEAN DISH AREA
74 SF
540 SF
WASH
110A
CART
275 SF
HOSP TRAY LINE
111B
MACHINE ROOM
738 SF
110B
228 SF
111A
VEST.
229 SF
REFRIG.
1810 SF
MAIN KITCHEN
4370 SF
D21, D22 V21, V22
TRASH ROOM
142 SF
160 SF
393 SF
REF'G
CORRIDOR
D19, D20 V19, V20
56 SF
1SW1
261 SF1HA3
REF'G
DN.
49 SF
FREIGHT
ELEV.
V39, V40 D39, D40
V37, V38 D37, D38
79 SF
105B
C
MEN'S RESTROOM
105A
69 SF
307 SF
106A
107A
TOILET
39 SF
D29, D30
NUTRITION
CLINIC
266 SF
OFFICE
DIETITIAN
D31, D32 V31, V32
H A
C O R R
ID
O R C V35, V36
D35, D36
S F
555 SF
V29, V3015
LOUVER
MOTORIZED
187 SF
VESTIBULE
245 SF
REF'G #1
D27, D28 V27, V28
D23, D24 V23, V24
12 V25, V26 D25, D26
164 SF
108A
SPVR. OFFICE
POTS & PANS
WASH AREA
478 SF
D13, D14 V13, V14
ELEV.
D15, D16 V15, V16
1317 SF
INGREDIENT ROOM
118A
234 SF
REF'G #3
305 SF
118B
REF'G #2
725 SF
RETHERM ROOM
EXISTING AC
SPLIT SYSTEM
A C
A C
A C
A C
AC
MANAGER
N&FS
USED FOR DATA
LOBBY
DINING ROOM
SEE DWG. E-49
(3)4"C
(1)4"C.,(2)1 1/2"FD
TO BUILDING 104
SEE NOTE 2
30" X 36" X 12"
PULL BOX
ELECT. CLOS.
24 SF
P1 V72
95 SF
D49, D50
OFFICE
81SF
1SW2
V49, V50
D N
105C
41 SF
E.M.S.
C
C O R R
ID
O R
D47, D48 V47, V4824
93 SF
STORAGE
256 SF
CLINICAL
DIETITIAN
D45, D46 V45, V46
349 SF
4"C
V43, V44
D43, D44N&FS
OFFICE
D41, D42 V41, V42
196 SF
OFFICE
S F
H A
C
CLEAN DISH AREA
74 SF
540 SF
WASH
110A
CART
275 SF
HOSP TRAY LINE
111B
MACHINE ROOM
738 SF
110B
228 SF
111A
VEST.
229 SF
REFRIG.
1810 SF
MAIN KITCHEN
4370 SF
D21, D22 V21, V22
TRASH ROOM
142 SF
160 SF
393 SF
REF'G
CORRIDOR
D19, D20 V19, V20
56 SF
1SW1
261 SF1HA3
REF'G
DN.
49 SF
FREIGHT
ELEV.
V39, V40 D39, D40
V37, V38 D37, D38
79 SF
105B
C
105A
69 SF
LADIE'S RESTROOM
307 SF
106A
107A
TOILET
39 SF
D29, D30
V33, V34 D33, D34
266 SF
D31, D32 V31, V32
H A
C O R R
ID
O R C V35, V36
D35, D36
S F
MAIL ROOM
555 SF
V29, V3015
LOUVER
MOTORIZED
187 SF
VESTIBULE
245 SF
REF'G #1
D27, D28 V27, V28
D23, D24 V23, V24
12 V25, V26 D25, D26
164 SF
108A
SPVR. OFFICE
POTS & PANS
WASH AREA
478 SF
D13, D14 V13, V14
ELEV.
D15, D16 V15, V16
1317 SF
INGREDIENT ROOM
118A
234 SF
REF'G #3
305 SF
118B
REF'G #2
725 SF
RETHERM ROOM
EXISTING AC
SPLIT SYSTEM
A C
A C
A C
A C
AC
MANAGER
N&FS
CWT
USED FOR DATA
DISCIPLINE/
SHEET NO. DESCRIPTION
F001 NOTES, SYMBOLS AND SCHEDULES
DISCIPLINE/
SHEET NO. DESCRIPTION
AD101 FLOOR PLAN AND ELEVATIONS-DEMOLITION
A101 FLOOR PLAN AND ELEVATIONS-NEW WORK
A102 FINISH PLANS, SCHEDULES & DETAILS
DISCIPLINE/
SHEET NO. DESCRIPTION
M001 NOTES, SYMBOLS AND SCHEDULES
M101 FLOOR PLANS & DETAILS
DISCIPLINE/
SHEET NO. DESCRIPTION
E101 FLOOR PLANS AND DETAILS
T100 COVER SHEET
HM101 HAZARDOUS MATERIALS
ADA101 HC ACCESSIBILITY, ABBREVIATIONS & SYMBOLS
DISCIPLINE/
SHEET NO. DESCRIPTION
P001 NOTES, SYMBOLS AND SCHEDULES
PD101 DEMOLITION FLOOR PLANS
P101 FLOOR PLANS
F101 FLOOR PLANS
Bath VAMC
WORK AREA
RENOVATE BATHROOMS,
B-24 AT BATH VAMC
987654321
987654321
A
B
C
D
E
F
A
B
C
D
E
F
Revisions: Date
Drawing Title
COR - STEPHEN WIGHTMAN
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project NumberCONSULTANTS: ARCHITECT/ENGINEERS:
Approved: Project Director
Office of Construction and Facilities
Management
BATH VA MEDICAL CENTER
76 VETERANS AVE.
BATH,NY 14810
08/01/2018 RAD GLG-AS-CCC
B-24
TRM DESIGN & PLANNING LLC
448 DELAWARE AVE. SUITE 202
BUFFALO, NEW YORK 14202
P: 716.946.9092
C&S COMPANIES
150 STATE STREET
SUITE 120
ROCHESTER, NEW YORK 14614
P: 585.325.9040
60% REVIEW PHASE
HAZARDOUS MATERIALS
HM101
528-A6-18-616
9/7/18
90% REVIEW PHASE 10/9/18
FINAL 11/26/18
R
266 SF
555 SF
TOILET
39 SF
107A
307 SF
106ATOILET
69 SF
105A
DIETICIAN OFFICE
196 SF
349 SF
4370 SF
41 SF
105C
E.M.S.
93 SF103
256 SF
95 SF
79 SF
105B
MALE STAFF
RESIDENT
TOILET
FIRST FLOOR PLAN
ELECT. CLOS.
24 SF
D N
1SW2
81SF
C O
RR
ID
O R
S F
1H A1
C O
RR
ID
O R
SF
1H
A2
725 SF
108A
SUPERVISOR
STOP POSITIVE SAMPLE FOR ASBESTOS
NO ASBESTOS DETECTED (NAD)
SAMPLE GREATER THAN 1% ASBESTOS
HATCHED AREAS INDICATE POSITIVE DETECTION OF
ASBESTOS CONTAINING BUILDING MATERIALS
APPROXIMATE SAMPLE LOCATION
1,2
9"x9" FLOOR TILE
LEGEND
25**
25*
12"x12" FLOOR TILE
12"x12" FLOOR TILE MASTIC
9"x9" FLOOR TILE MASTIC
ACM PIPE FITTING LOCATION AND QUANTITY10
ACM BASE COVE MASTIC
G ACM WINDOW GLAZING
*EXTERIOR WINDOW AND FRAME CAULK, EXPANSION JOINT
CAULK, AND LOUVER CAULK ARE ACM*
*SAMPLES 01A, 01B, 01C, AND 01D ARE ACM MUDDED
FITTINGS COLLECTED IN THE ATTIC*
SAMPLES 2A, 2B, AND 2C ARE 2'x1' CEILING TILES
IDENTIFIED AS NON-ACM COLLECTED IN THE ATTIC
GRAY DOOR FRAME CAULK
6" TAN COVE BASE
TAN MASTIC UNDER 6" COVE
BASE,TAN WINDOW FRAME CAULK**
TAN 4" COVE BASE, MASTIC BEHIND.
4" LIGHT BROWN COVE BASE,
TAN MASTIC BEHIND.
WALL PLASTER BASE & SKIM COAT,
12" FLOOR TILE, GRAY W/BROWN STREAK,
12" FLOOR TILE, TAN W/BROWN FLECK,
BLACK MASTIC UNDERNEATH.
DRYWALL, SEAM TAPE, JOINT COMPOUND,
6" BLACK COVE BASE, MASTIC BEHIND.
EXTERIOR WINDOW FRAME &
EXPANSION JOINT CAULK.
BROWN LINOLEUM,
MASTIC UNDERNEATH.,
MASTIC UNDERNEATH**
2'X2' LIP CROWS FOOT
W/PIN DOT.
2'X4' LIP. POCK
W/ PIN DOT.
03A, 04A, 05A
BLACK 6" COVE BASE
DRYWALL
6" BLACK COVE BASE,
MASTIC BEHIND.
2'X4' LIP, LARGE
FISSURE W/PIN DOT
EXTERIOR GRAY LOUVER
FRAME CAULK**
2" DARK TAN FLOOR TILE,
MASTIC AND TAR UNDER.
WHITE EXTERIOR WINDOW FRAME CAULK**
EXTERIOR EXPANSION JOINT CAULK GRAY EXTERIOR DOOR
FRAME CAULK
2'X2' LIP, REGULAR
W/PIN DOT
GRAY DOOR
FRAME CAULK
TAN WINDOW FRAME CAULK**
TAN MASTIC UNDER 6" COVE BASE,
2'X2' LIP. CROWS FOOT
W/ PIN DOT.
NAME
NFS
HEALTHY KITCHEN
NFS
NUTRITIONAL CLINIC
NAME
NFS
DINING ROOM
NFS
DIETICIAN
NAME
NFS
PSA
NAME
NFS
PROGRAM MANG.
NAME
NFS
NAME
NFS
SUPERVISOR
NAME
NFS
DIET COMMUNICATION OFFICE
NAME
NFS
SCOPE OF WORK AREA
SCALE: N.T.S
BASEMENT FLOOR PLAN
SCALE: N.T.S
BS109
1274 SF
E.M.S.
LOCKER ROOM
BS110
892 SF
LOCKER ROOM
BS113
374 SF
LOUNGE
BS112
125 SF
LOUNGE
BS111
170 SF
ROOM
BS108
3461 SF
MACHINE
BS116
48 SF
ROOM
BAGGAGE AND CLOTHING
ELEV.
BS114
MALE
FEMALE
FEMALEMALE
PI
PE
S
PA
C E
CORRIDOR
UP
FAN
UP
BSHA2 452 SF
292 SFBATHRM 343 SFBATHRM BS115
SF
BS
C O
RR
ID
O R
SF
BS
H
A1
BS
SW
22 SF
H.A.C.
BS119
STOP POSITIVE SAMPLE FOR ASBESTOS
NO ASBESTOS DETECTED (NAD)
SAMPLE GREATER THAN 1% ASBESTOS
HATCHED AREAS INDICATE POSITIVE DETECTION
OF ASBESTOS CONTAINING BUILDING MATERIALS
APPROXIMATE SAMPLE LOCATION
1,2
9"x9" FLOOR TILE
LEGEND
25**
25*
ACM PIPE INSULATION LOCATION
12"x12" FLOOR TILE
12"x12" FLOOR TILE MASTIC
ACM PIPE FITTING LOCATION
AND QUANTITY
*EXTERIOR WINDOW AND FRAME
CAULK, EXPANSION JOINT CAULK,
AND LOUVER CAULK ARE ACM*
9"x9" FLOOR TILE MASTIC
12" FLOOR TILE, TAN
W/ BROWN FLECK*
15B**23A, 23B
4" COVE BASE,
BROWN.
12" FLOOR TILE, TAN W/
BROWN FLECK**, 4"
COVE BASE, BROWN
26A, 27ADRYWALL, SEAM TAPE,
JOINT COMPOUND.
MUDDED FITTING**
RED PENETRATION CAULK,
PARTICLE BOARD ABOVE
CEILING.
DEBRIS ON FLOOR.
DRYWALL, SEAM TAPE,
JOINT COMPOUND
12" FLOOR TILE, LIGHT GREEN
W/ GRAY FLECK. 4" COVE
BASE, MASTIC BEHIND.
PIPE END CAP
INSULATION
MAG. PIPE INSULATION**,
2'X2' LIP, CROWS FOOT W/PIN DOT
12" FLOOR TILE, CREAM W/ PINK AND
GRAY FLECK. MASTIC UNDERNEATH.
12" FLOOR TILE, CREAM W/BROWN
STREAKS*. MASTIC UNDERNEATH**.
UP
SCOPE OF WORK AREA
GENERAL NOTES
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT
SPECIFICATION AND ALL FEDERAL, STATE AND LOCAL REGULATIONS INCLUDING BUT
NOT LIMITED TO: OSHA 29 CFR 1926, 40 CFR PART 61 SUBPART M AND
SPECIFICATION SECTION 02 82 13.19.
2. ALL MATERIAL LOCATIONS ARE APPROXIMATE AND FOR GENERAL ORIENTATION ONLY.
CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF EXISTING CONDITIONS.
3. THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION WITH THE OWNER OR
THE OWNER'S REPRESENTATIVE TO ESTABLISH THE LOCATION OF THE
DECONTAMINATION ENCLOSURES, WASTE DUMPSTERS AND/OR TRAILERS, NEGATIVE
AIR EXHAUST LOCATIONS, WATER SOURCES, TEMPORARY POWER, ETC. IN ADDITION,
COORDINATION WILL BE REQUIRED FOR HVAC AND ELECTRIC SHUTDOWN.
4. CONTRACTOR IS RESPONSIBLE FOR ALL TOOLS, EQUIPMENT AND SUPPLIES. THE
OWNER OR OWNER'S REPRESENTATIVE IS NOT LIABLE FOR THEFT OR DAMAGE.
5. CONTRACTOR IS RESPONSIBLE FOR KEEPING THE WORK AREA AND THE ADJACENT
AREAS IN A CLEAN AND SAFE CONDITION. CONTRACTOR SHALL ENSURE THAT
UNCERTIFIED PERSONNEL OR UNAUTHORIZED VISITORS DO NOT ENTER ACTIVE WORK
AREAS AT ANY TIME.
6. VAMC BATH PROVIDED THESE DRAWINGS WITHOUT INDEPENDENT REPORT.
NOTE: DRAWING PROVIDED FOR REFERENCE
ONLY, BACKGROUND PROVIDED BY VAMC.
NOTE: DRAWING PROVIDED FOR REFERENCE
ONLY, BACKGROUND PROVIDED BY VAMC.
987654321
987654321
A
B
C
D
E
F
A
B
C
D
E
F
Revisions: Date
Drawing Title
COR - STEPHEN WIGHTMAN
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project NumberCONSULTANTS: ARCHITECT/ENGINEERS:
Approved: Project Director
Office of Construction and Facilities
Management
BATH VA MEDICAL CENTER
76 VETERANS AVE.
BATH,NY 14810
08/01/2018 RAD GLG-AS-CCC
B-24
TRM DESIGN & PLANNING LLC
448 DELAWARE AVE. SUITE 202
BUFFALO, NEW YORK 14202
P: 716.946.9092
C&S COMPANIES
150 STATE STREET
SUITE 120
ROCHESTER, NEW YORK 14614
P: 585.325.9040
60% REVIEW PHASE
HC ACCESSIBILITY,
ABBREVIATIONS & SYMBOLS
ADA101
528-A6-18-616
9/7/18
90% REVIEW PHASE 10/9/18
FINAL 11/26/18
R
LAV. CLEARANCES (ADA/ANSI) SCALE: 1/2"=1'-0"
DETAIL
" M
IN
60" MIN.
16" -18" CLR.
30" MIN.
REFLECTIVE
8" MIN.
KNEE CLR.
" M
IN
" M
AX
9" M
IN
PLAN
" M
IN
6" MAX.
TOE CLR.
BOTTOM OF
SURFACE
17" MIN.
19" MAX.
SIDE ELEVATION
" M
AX
CLEAR
FLOOR
(PROVIDED FOR REFERENCE)
" M
AX
" M
IN
FLOOR
SPACE
" M
IN
CLEAR
15" MIN.
SPACE
SIDE APPROACH SCALE: 1/2"=1'-0"
DOOR CLEARANCE
4' -0
2'-8" 2'-0"
5'-0"
3' -6
M
IN
CLEAR
REQUIRED
CLEAR SPACE
REQUIRED
CLEAR SPACE
" I
F D
O O
R H
A S
C
LO
SE
R
L
AT
C
H
M
IN
" I F
D O
O R
H A
S C
LO
SE
R
L
AT
C H
MIN.
3 (PROVIDED FOR REFERENCE)
FRONT APPROACH SCALE: 1/2"=1'-0"
DOOR CLEARANCE
5'
-0
2'-8"
4' -0
4 (PROVIDED FOR REFERENCE)
M
IN
M
IN
. CLEAR
REQUIRED
CLEAR SPACE
18" MIN. INTERIOR
24" MIN. EXTERIOR
12" MIN. IF DOOR
HAS CLOSER &
LATCH
REQUIRED
CLEAR SPACE
RESTROOM FIXTURE AND ACCESSORY MOUNTING HEIGHTS SCALE: 1/2"=1'-0"
DETAIL
" M
AX
4' -0
2' -5
" 3' -4
2' -9
2' -9
4' -0
1'-111/16"
1' -8
" T
O
6"
1'-0" 3'-6"
MIN.
1/
4"
7"-9"
4' -0
W.C.
INSTALL FLUSH CONTROL
VALVE ON WIDE SIDE OF
STALL
PAPER TOWEL
DISPENSER/WASTE
CONTAINER
PAPER TOWEL
SLOT
2 (PROVIDED FOR REFERENCE)
VISIBLE
ALARM
SIGNAL
LAVATORY
TO
P
O F
BO
X
INSULATE HOT
WATER & DRAIN
PIPES (TYP.)
BOTTOM OF
REFLECTIVE
SURFACE
FINISH
FLOOR
(F R.
F
IN
. F
LR
TO
S H
EL
F)
(F R.
F
IN
. F
LR
TO
S H
EL
F)
" M
AX
C
LR
. M
AX
M
IN
TO
P
O F
BO
X
BABY CHANGING STATION
FINISH FACE OF WALL
GRAB BAR FRONT VIEW SIDE VIEW
FACE OF
FINISHED WALL
MAX.
" S
EE
E
LE
C
T.
D
W G
S.
(M
IN
(R
.O
(M
AX
ST
AN
D
AR
D M
TG
. H
EI
G
H T
SOAP DISPENSER
SCALE
X
X
X-X
X X-X
X X-X
X X-X
X X-X
ROOM NAME
X-X
X-X
B
SUBTITLE
DRAWING TITLEXX
A
X X-X
X X-X
D
X X-X
XXX
X
C
A B B R E V I A T I O N S
ELEVATION
ELECTRIC
EQUIPMENT
EXPANSION/EXPOSED
EXTERIOR
EQUIP.
EL/ELEV
ELEC
EXP
EXTR.
EXT.
EQ.
EXTRUDED
EQUAL
EXISTING
ALUM
ASPH
A.F.F.
AB.
ACT
ACST
ACRY
ALUMINUM
ASPHALT
ABOVE FINISH FLOOR
ALUMINUM THRESHOLD
ABOVE
ACOUSTIC CEILING TILE
ACOUSTIC
ACRYLIC WALL COATING
ADJUSTABLE / ADJACENT
EXG./EXIST.
S
MAR
MAS
M.O.
MACH
MAX
MECH
M.C.
M.H.
MTL
MISC
MIN
MLDG
MAT / MAT'L
MARBLE
MASONRY
MASONRY OPENING
MATERIAL
MACHINE
MAXIMUM
MECHANICAL
MEDICINE CABINET
MAN HOLE
METAL
MINIMUM
MISCELLANEOUS
MOULDING
M.R.
MRD
MOP RECEPTOR
MOISTURE RESISTANT DRYWALL
MTP METAL TOILET PARTITION
M.B. MARKERBOARD
SDL
SECT
SGT
SHT
SLV
SPEC
SQ
S./P.V.
S.S.
STL
SC
STD
ST.STL.
SUSP
SW
STR.
SADDLE
SECTION
STRUCTURAL GLAZED TILE
SHEET
SLEEVE
SPECIFICATION
STAINED / POLYURETHANE VARNISH
SQUARE
SERVICE SINK
STEEL
STANDARD
STAIN
STAINLESS STEEL
SUSPENDED
SWITCH
STRUCTURE
STAINED CONCRETE
FLOOR DRAINF.D.
F.F.
F.E.
FINISH FLOOR
FIRE EXTINGUISHER
FLOOR
F.M.
FIN
F.O.
FLOOR MATS
FRAMED OPENING
FINISH
F.R.P.
F.R. FIRE RESISTANT
FL /FLR
FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FT FLOOR TILE
TYP.
TEMP
TER./TERR
T.S.
T & G T.C.
T.B.B.
T/ T.O.
T.BD. / T.B.
TONGUE & GROOVE
TYPICAL
TEMPERED
TUBE STEEL
TERRAZZO
TERRA COTTA
TACK BOARD
TILE BACKING BOARD
TOP OF...
TREADS
GL
GR
GRD
G.P.
GYP.BD.
GA
GALV
GRADE
GROUND
GREASE PROOF
GYPSUM BOARD
GAUGE
GALVANIZED
GLASS
UNFIN
U.V.
U / S U.N.O.
UNFINISHED
UNIT VENTILATOR
UNDERSIDE
UNLESS NOTED OTHERWISE
HAZ HAZARDOUS
V.P.
VAT
V.B.
VB PT
VWC
VSF
VENT
V.I.F.
VEST
VCT
VAPOR BARRIER
VENT PIPE
VENTILATOR
VINYL WALL COVERING
VINYL SHEET FLOORING
VERIFY IN FIELD
VESTIBULE
VINYL COMPOSITION TILE
VINYL ASBESTOS TILE
LIQUID APPLIED VAPOR BARRIER PAINT
W.W.F.
W.V.
WTCS
W.I.
WT
W.P.
W.L.
W.F.
WD
WCP
W.CR.
WELDED WIRE FABRIC
WATER VALVE
WALL TEXTURED COATING SYSTEM
WROUGHT IRON
WALL TILE
WATER PROOFING
WIDE FLANGE
WATER LINE
WOOD
WEATHERCAP
WATER COOLER
HT
H.M.
H.P.
HEIGHT
HOLLOW METAL
HIGH POINT
I.D.
INSUL
INV
INT./INTER.
INSIDE DIAMETER
INSULATION
INVERT
INTERIOR
JAN
JT
JANITOR
JOINT
KAL KALAMEIN
L
LINO
LAM
LGT
ANGLE
LINOLEUM
LAMINATE
LENGTH
HD. WD. HARD WOOD
B/
B.F.F.
BLK
BSMT
BAL.
BOTTOM OF...
BOARD
BELOW FINISH FLOOR
BLOCK
BASEMENT
BOTH SIDES
BALANCE
BASE TILE
CAB
CEM
CER
C.L.
CLG
C.M.P.
CH.BD.
CLR
CORR.
C,O, C.M.U.
COND
CONST
CONTR
CONV
COMPO
COP
COL.
CONC.
C.M.T.
C.T.W
CATCH BASIN
CAST IRON
CABINET
CEMENT
CERAMIC
COURSES/CHANNEL
CENTER LINE
CEILING
CORRUGATED METAL PIPE
CHALK BOARD
COOLER
CLEAN OUT
CONCRETE MASONRY UNIT
CERAMIC TILE
COLD ROLLED
CONTROL JOINT
CARPET
CORRIDOR
COLUMN
CONCRETE
CONDUCTOR
CONSTRUCTION
CONTRACTOR
CONVECTOR
COPPER
COMPOSITION
CERAMIC MOSAIC TILE
CERAMIC TILE WAINSCOT
DWG
DET
DIM
DRAWING
DRYWALL/GYP. BD.
DRINKING FOUNTAIN
DETAIL
DRAIN INLET
DIAMETER
DIMENSION
DITTO
DIVISION
DOWN
DRAIN
N.I.C.
NO
NOT IN CONTRACT
NUMBER
OBS OBSCURE
O.C. ON CENTER
OPNG
OPP
OPENING
OPPOSITE
O.D. OUTSIDE DIAMETER
O.S.C.I OWNER SUPPLIED,CONTRACTOR INSTALLED
O.S.O.I OWNER SUPPLIED,OWNER INSTALLED
P.C.T.
PART
PART.BD.
PLMB
POL
PREFAB
PT
PLYWD
P.A.F.
P.BD.
PLAS / PLS
P.L. / P.LAM.
P.L.
PF / PRE-FIN. PRE-FINISHED
PORCELIN CERAMIC TILE
PARTITION
PLASTER
PARTICLE BOARD
PLUMBING
PLATE
PLYWOOD
POLISHED
PLASTIC LAMINATE
PREFABRICATED
PAINT
PEG BOARD
POWDER ACTUATED FASTENER
P.T.
PV
PRESSURE TREATED
POLYURETHANE VARNISH
Q.T. QUARRY TILE
RB
REF
REG
REINF
R
RAD
RUBBER BASE
REFRIGERATOR
REGISTER
REINFORCING
RISER /RADIUS
RADIATOR
R.D.
R.O.
RWL
RUB
RM
R.T.U.
REQ / REQ'D
ROOF DRAIN
ROUGH OPENING
RAIN WATER LEADER
RUBBER
ROOM
ROOF TOP UNIT
REQUIRED
BD
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
XXX
SECTION NUMBER
SHEET NUMBER
X
SURFACE
0'-0"
SHEET NUMBER
ELEVATION LETTER
ENLARGED AREA IDENTIFICATION
PLAN DETAIL IDENTIFICATION
WALL SECTION IDENTIFICATION
BUILDING SECTION IDENTIFICATION
INTERIOR ELEVATION IDENTIFICATION
PARTIAL SECTION OR DETAIL
IDENTIFICATION
STEEL
REVISION NUMBER
CONCRETE
EARTH
RIGID INSULATION
GYPSUM BOARD
PLYWOOD
INSULATION (BATT OR ICYNENE)
WOOD
MASONRY/BLOCK
DOOR NUMBER
ELEVATION TARGET
ROOM NAME & NUMBER
DRAWING TITLE IDENTIFICATION
NORTH ARROW
BRICK
CRUSHED STONE
S Y M B O L S
LETTER
OR
987654321
987654321
A
B
C
D
E
F
A
B
C
D
E
F
Revisions: Date
Drawing Title
COR - STEPHEN WIGHTMAN
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project NumberCONSULTANTS: ARCHITECT/ENGINEERS:
Approved: Project Director
Office of Construction and Facilities
Management
BATH VA MEDICAL CENTER
76 VETERANS AVE.
BATH,NY 14810
08/01/2018 RAD GLG-AS-CCC
B-24
TRM DESIGN & PLANNING LLC
448 DELAWARE AVE. SUITE 202
BUFFALO, NEW YORK 14202
P: 716.946.9092
C&S COMPANIES
150 STATE STREET
SUITE 120
ROCHESTER, NEW YORK 14614
P: 585.325.9040
60% REVIEW PHASE
FLOOR PLAN AND ELEVATIONS
-DEMOLITION
AD101
528-A6-18-616
9/7/18
90% REVIEW PHASE 10/9/18
FINAL 11/26/18
R
@ EXIST. STAFF RESTROOM SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONA
1'-65/8" 3'-71/4" 1'-43/4" 3'-71/4" 2'-105/8"EXIST. VENT PIPE TO
BE RELOCATED
EXIST. STEAM
RADIATOR
EXIST.
BASEBOARD
EXIST. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
T.O. WALL RECESS/SILL
+2'-8"
3 16
86 10
LIMIT OF FINISH REMOVAL DOWN TO STUDS IS
UNDERSIDE OF EXISTING PLATFORM FRAMING 15
@ EXIST. STAFF RESTROOM SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONB
EXIST. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
EXIST. DOOR
AND FRAME
EXIST. TOWEL
DISPENSER/
HAND DRYER
EXIST.
BASEBOARD
17EXIST. SWITCH
EXIST. SUBSTRATE TO BE REMOVED
DOWN TO FACE OF EXISTING
STUD (SEE DEMO. PLAN FOR
EXTENT OF REMOVAL)
LIMIT OF FINISH REMOVAL DOWN TO STUDS IS
UNDERSIDE OF EXISTING PLATFORM FRAMING
@ EXIST. STAFF RESTROOM SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONC
3'-7" 2'-91/2" 5'-0" 1'-8"
EXIST. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
EXIST. VANITY
LAMP
EXIST.
SIGNAGE
EXIST.
ACCESSORIES
EXIST.
BASEBOARD
EXIST. PLUMBING
FIXTURES
EXIST. STALL
PARTITIONS
EXIST. SUBSTRATE TO BE REMOVED DOWN TO FACE OF EXISTING
STUD (SEE DEMO. PLAN FOR EXTENT OF REMOVAL)
EXIST. SWITCH 17
REUSE EXIST. FLOOR
PENETRATION
LIMIT OF FINISH REMOVAL DOWN TO STUDS IS UNDERSIDE OF EXISTING PLATFORM FRAMING
@ EXIST. RESIDENT RESTROOM SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONE
EXIST. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
EXIST. PLUMBING
FIXTURES
5EXIST. GRAB BAR
EXIST. STALL
PARTITIONS
EXIST.
BASEBOARD
EXIST.
ACCESSORIES
EXIST.
VANITY LAMP
EXIST. PANEL
EXIST.
SWITCH
EXIST. SUBSTRATE TO BE REMOVED DOWN
TO FACE OF EXISTING STUD (SEE DEMO.
PLAN FOR EXTENT OF REMOVAL)
EXIST. VENT PIPE TO
BE REWORKED
EXIST. VENT PIPE TO
BE RELOCATED
REUSE EXIST. FLOOR
PENETRATION
LIMIT OF FINISH REMOVAL DOWN TO STUDS IS
UNDERSIDE OF EXISTING PLATFORM FRAMING
@ EXIST. RESIDENT RESTROOM SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONG
EXIST. STEAM
RADIATOR
EXIST. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
EXIST. STALL
PARTITION 6
EXIST.
BASEBOARD
EXIST. SUBSTRATE TO BE
REMOVED DOWN TO
FACE OF EXISTING STUD
(SEE DEMO. PLAN FOR
EXTENT OF REMOVAL)
EXIST. SUBSTRATE TO BE REMOVED DOWN TO FACE OF EXISTING
STUD (SEE DEMO. PLAN FOR EXTENT OF REMOVAL) 19
LIMIT OF FINISH REMOVAL DOWN TO STUDS IS UNDERSIDE OF EXISTING PLATFORM FRAMING
GENERAL DEMOLITION NOTES
1. PERMITS AND INSPECTIONS:
SECURE ALL PERMITS NECESSARY OR REQUIRED TO PERFORM THE INDICATED DEMOLITION
WORK. COORDINATE ALL INSPECTIONS WITH THE LOCAL AUTHORIES HAVING
JURISDICTION.
2. MEANS AND METHODS:
THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS REGARDING
DEMOLITION WORK, INCLUDING ANY BRACING OR SHORING DESIGN AND
ERECTION.
3. SALVAGE:
COORDINATE WITH THE OWNER THE EXTENT OF ITEMS TO BE CONSIDERED AS SALVAGE
(THAT IS, PROPERTY OF THE CONTRACTOR) AND WHAT IS TO BE TURNED OVER TO
THE OWNER).
4. COLLATERAL DAMAGE TO PROPERTY:
ANY UNSCHEDULED DAMAGE CAUSED TO ADJACENT AREAS OR TO COMMON AREAS
SHALL BE PROMPTLY REPAIRED OR REPLACED AT NO COST TO OWNER.
5. NEATNESS:
CONDUCT ALL DEMOLITION OPERATIONS AND DEBRIS REMOVAL TO ENSURE MINIMUM
INTERFERENCES WITH STREETS, WALKWAYS AND OTHER SPACES ADJACENT TO THE
WORK. MAIINTAIN THESE AREAS FREE OF DUST, DIRT, AND DEBRIS CAUSED BY THE
DEMOLITION WORK. IF NECESSARY, BROOM CLEAN SURROUNDING AREAS AT THE
COMPLETION OF EACH DAYS WORK.
6. UTILITIES:
MAINTAIN ALL EXISTING UTILITIES TO REMAIN AND PROTECT FROM DAMAGE DURING
DEMOLITION. DO NOT INTERRUPT EXISTING UTILITIES UNLESS AUTHORIZED IN WRITING
BY THE OWNER
7. STRUCTURAL LOADING:
LOCATE DEMOLITION EQUIPMENT AND PROMPTLY REMOVE DEBRIS TO AVOID
IMPOSING EXCESSIVE LOADS ON SUPPORTING STRUCTURE.
8. CUTTING AND PATCHING IN EXISTING CONSTRUCTION:
A. NEATLY CUT EXISTING CONSTRUCTION AS REQUIRED FOR INSTALLATION
OF WORK INCLUDED UNDER THIS CONTRACT.
B. CUT IN MANNER TO AVOID DAMAGE TO ADJACENT WORK.
C. PATCH ALL EXISTING WORK DISTURBED BY INSTALLATION OF NEW WORK
TO MATCH ADJACENT FINISH IN APPROVED MANNER. SUCH PATCHING MAY
INCLUDE, BUT NOT BE LIMITED TO INSULATION. WALLS AND WALL COVERING,
PAINT, CEILING MATERIALS AND/OR TILES, FLOOR COVERING ETC.
D. CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL WORK OR
EQUIPMENT DAMAGE DURING COURSE OF CUTTING PROCESS.
E. PATCH ALL CUT HOLES OR HOLES LEFT BY REMOVAL OF EQUIPMENT OR
FIXTURES IN APPROVED MANNER.
9. HAZARDOUS MATERIALS:
IF THE CONTRACTOR SUSPECTS THAT HE OR SHE HAS DISCOVERED HAZARDOUS MATERIALS
IN THE COURSE OF THEIR WORK THEY SHALL IMMEDIATELY NOTIFY THE OWNER'S
REPRESENTATIVE BEFORE PROCEEDING WITH THE WORK.
10. DIMENSIONS ON DEMOLITION PLANS AND ELEVATIONS ARE PROVIDED FOR
REFERENCE ONLIY. SEE NEW WORK FOR NEW DIMENSIONS IN SCOPE OF WORK
AREA.
REMOVE EXISTING VINYL TILE. (SEE HM DRAWINGS INCLUDED IN THIS SET.)
REMOVE EXISTING SHEET VINYL FLOORING AND TRANSITION STRIPS AT DOORWAYS.
REMOVE ALL EXISTING WALL BASES ( VINYL, WOOD, ETC.); SEE H.M. DRAWINGS
INCLUDED IN THIS SET.
REMOVE ALL PLUMBING FIXTURES (SEE PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION)
REMOVE ALL RESTROOMS ACCESSORIES (INCLUDING BUT NOT LIMITED TO GRAB
BARS, SOAP DISPENSERS, PAPER TOWEL DISPENSERS, ETC.) AND TURN OVER TO
VAMC.
REMOVE EXISTING TOILET STALL PARTITIONS AND PRIVACY SCREENS
REMOVE ALL WINDOW TREATMENT AND ASSOCIATED ACCESSORIES (OBSCURE
WINDOW SHALL REMAIN)
CAREFULLY REMOVE ALL ARTWORK AND TURN OVER TO VAMC.
SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL
DEMOLITIONS AND REMOVALS.
REMOVIE EXISTING ACOUSTICAL TILE CEILING SYSTEM.
REMOVE EXISTING WOOD DOOR, HOLLOW METAL FRAME AND DOOR HARDWARE.
REMOVE PORTION OF EXISTING PARTITION FOR NEW WIDENED OPENING AT DOOR
AND FRAME.
REMOVE EXISTING ACCESS PANEL ON PARTITION.
REMOVE FINISH DOWN TO STUDS IN THIS AREA. SEE NEW WORK PLAN FOR
ASSOCIATIED WORK.
EXISTING PLATFORM IN ATTIC ABOVE TO REMAIN. LIMITED PENETRATIONS FOR NEW
WORK SHALL BE PROVIDED AND BE FIRE STOPPED AS REQUIRED.
REMOVE QUARTER ROUND WOOD MOLDING.
RELOCATE EXISTING ELECTRICAL DEVICE, SEE ELEC. DRAWINGS FOR NEW WORK.
REMOVE ALL SIGNAGE AND TURN OVER TO VAMC.
REMOVE EXISTING SUBSTRATE DOWN TO EXISTING FACE OF STUD (ON INTERIOR/RESTROOM
SIDE ONLY)
REMOVE EXISTING WINDOW SILL TO ALLOW INSTALLATION OF NEW FINISHES.
KEY DEMOLITION NOTES
6' -1
01/ 4"
5' -9
3/ 4"
13'-1"±
13'-1"±
A
B
C
D AD101
E
F
G
H AD101
EXIST. STEAM RADIATOR
EXIST. STEAM RADIATOR
TEMP. ACCESS
MAN DOOR
APPROX. LOCATION
FOR TEMP CONST.
PARTITION ( GC TO VERIFY
LOCATION W/ VAMC )
EXIST. SIGNAGE
EXIST. ATTIC ABOVE
EXIST. SIGNAGE
EXIST. VENT PIPE TO BE
RELOCATED &
REWORKED
EXIST. VENT PIPE TO BE
RELOCATED &
REWORKED
EXIST. WINDOW
TO REMAIN
EXIST. WINDOW
TO REMAIN
EXIST. PLUMBING
FIXTURES TO BE
REMOVED (TYP.)
EXIST. DOOR & FRAME
TO BE REMOVED
EXIST. DOOR & FRAME
TO BE REMOVED
EXISTING WALL RECESS
(OLD WINDOW)
EXISTING WALL RECESS
(OLD WINDOW)
EXIST. ACCESS TO ATTIC
SPACE IN CEILING
CUT PENETRATION INTO
EXIST. WINDOW PANEL
FOR NEW EXHAUST DUCT
EXISTING
BOTTLE
VENDING
MACHINE
EXISTING
BOTTLE
VENDING
MACHINE
EXISTING
BOTTLE
VENDING
MACHINE
1HA1
EXISTING CORRIDOR
105A
TOILET ROOM
EXISTING STAFF
105B
TOILET ROOM
EXISTING RESIDENT
EXISTING/ DEMOLITION SCALE: 1/2"=1'-0"
FLOOR PLAN1
LOBBY
DINING ROOM
SEE DWG. E-49
(3)4"C
(1)4"C.,(2)1 1/2"FD
TO BUILDING 104
SEE NOTE 2
30" X 36" X 12"
PULL BOX
ELECT. CLOS.
24 SF
P1 V72
95 SF
D49, D50
OFFICE
81SF
1SW2
V49, V50
D N
105C
41 SF
E.M.S.
C
C O R R
ID
O R
D47, D48 V47, V4824
93 SF
STORAGE
256 SF
CLINICAL
DIETITIAN
D45, D46 V45, V46
349 SF
4"C
V43, V44
D43, D44N&FS
OFFICE
D41, D42 V41, V42
196 SF
OFFICE
S F
H A
C
CLEAN DISH AREA
74 SF
540 SF
WASH
110A
CART
275 SF
HOSP TRAY LINE
111B
MACHINE ROOM
738 SF
110B
228 SF
111A
VEST.
229 SF
REFRIG.
1810 SF
MAIN KITCHEN
4370 SF
D21, D22 V21, V22
TRASH ROOM
142 SF
160 SF
393 SF
REF'G
CORRIDOR
D19, D20 V19, V20
56 SF
1SW1
261 SF1HA3
REF'G
DN.
49 SF
FREIGHT
ELEV.
V39, V40 D39, D40
V37, V38 D37, D38
79 SF
105B
C
ROOM
RESIDENT TOILET
105A
69 SF
STAFF TOILET
ROOM
307 SF
106A
107A
TOILET
39 SF
D29, D30
V33, V34 D33, D34
NUTRITION
CLINIC
266 SF
OFFICE
DIETITIAN
D31, D32 V31, V32
H A
C O R R
ID
O R C V35, V36
D35, D36
S F
MAIL ROOM
555 SF
V29, V3015
LOUVER
MOTORIZED
187 SF
VESTIBULE
245 SF
REF'G #1
D27, D28 V27, V28
D23, D24 V23, V24
12 V25, V26 D25, D26
164 SF
108A
SPVR. OFFICE
POTS & PANS
WASH AREA
478 SF
D13, D14 V13, V14
ELEV.
D15, D16 V15, V16
1317 SF
INGREDIENT ROOM
118A
234 SF
REF'G #3
305 SF
118B
REF'G #2
725 SF
RETHERM ROOM
EXISTING AC
SPLIT SYSTEM
A C
A C
A C
A C
AC
MANAGER
N&FS
CWT
USED FOR DATA
LOBBY
DINING ROOM
SEE DWG. E-49
(3)4"C
(1)4"C.,(2)1 1/2"FD
TO BUILDING 104
SEE NOTE 2
30" X 36" X 12"
PULL BOX
ELECT. CLOS.
24 SF
P1 V72
95 SF
D49, D50
OFFICE
81SF
1SW2
V49, V50
D N
105C
41 SF
E.M.S.
C
C O R R
ID
O R
D47, D48 V47, V4824
93 SF
STORAGE
256 SF
CLINICAL
DIETITIAN
D45, D46 V45, V46
349 SF
4"C
V43, V44
D43, D44N&FS
OFFICE
D41, D42 V41, V42
196 SF
OFFICE
S F
H A
C
CLEAN DISH AREA
74 SF
540 SF
WASH
110A
CART
275 SF
HOSP TRAY LINE
111B
MACHINE ROOM
738 SF
110B
228 SF
111A
VEST.
229 SF
REFRIG.
1810 SF
MAIN KITCHEN
4370 SF
D21, D22 V21, V22
TRASH ROOM
142 SF
160 SF
393 SF
REF'G
CORRIDOR
D19, D20 V19, V20
56 SF
1SW1
261 SF1HA3
REF'G
DN.
49 SF
FREIGHT
ELEV.
V39, V40 D39, D40
V37, V38 D37, D38
79 SF
105B
C
ROOM
RESIDENT TOILET
105A
69 SF
STAFF TOILET
ROOM
307 SF
106A
107A
TOILET
39 SF
D29, D30
V33, V34 D33, D34
NUTRITION
CLINIC
266 SF
OFFICE
DIETITIAN
D31, D32 V31, V32
H A
C O R R
ID
O R C V35, V36
D35, D36
S F
MAIL ROOM
555 SF
V29, V3015
LOUVER
MOTORIZED
187 SF
VESTIBULE
245 SF
REF'G #1
D27, D28 V27, V28
D23, D24 V23, V24
12 V25, V26 D25, D26
164 SF
108A
SPVR. OFFICE
POTS & PANS
WASH AREA
478 SF
D13, D14 V13, V14
ELEV.
D15, D16 V15, V16
1317 SF
INGREDIENT ROOM
118A
234 SF
REF'G #3
305 SF
118B
REF'G #2
725 SF
RETHERM ROOM
EXISTING AC
SPLIT SYSTEM
A C
A C
A C
A C
AC
MANAGER
N&FS
CWT
USED FOR DATA
@ EXIST. STAFF RESTROOM SCALE: 3/8"=1'-0"
INTERIOR ELEVATIOND
EXIST. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
EXIST. WINDOW
EXIST. VENT PIPE TO
BE RELOCATED
EXIST. STEAM
RADIATOR
EXIST. TOILET
TISSUE DISPENSER
EXIST. PLUMBING
FIXTURE
EXIST.
BASEBOARD
LIMIT OF FINISH REMOVAL DOWN
TO STUDS IS UNDERSIDE OF
EXISTING PLATFORM FRAMING 15
@ EXIST. RESIDENT RESTROOM SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONF
EXIST. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
EXIST. DOOR AND FRAME
EXIST. BASEBOARD
EXIST. TOWEL DISPENSER
EXIST. SWITCH 17
EXIST. SUBSTRATE TO BE REMOVED
DOWN TO FACE OF EXISTING
STUD (SEE DEMO. PLAN FOR
EXTENT OF REMOVAL)
LIMIT OF FINISH REMOVAL DOWN TO STUDS IS
UNDERSIDE OF EXISTING PLATFORM FRAMING
@ EXIST. RESIDENT RESTROOM SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONH
EXIST. CLG. HT.
+8'-41/2"±
F.F.
0'-0"
EXIST.
WINDOW
EXIST. VENT PIPE TO
BE RELOCATED
EXIST. PLUMBING
FIXTURE
5EXIST. GRAB BAR EXIST. TOILET
TISSUE DISPENSER
EXIST. STEAM
RADIATIOR
EXIST.
BASEBOARD
LIMIT OF FINISH REMOVAL DOWN
TO STUDS IS UNDERSIDE OF
EXISTING PLATFORM FRAMING 15
EXISTING FIRST FLOOR OF B-24 BLDG. SCALE: N.T.S.
KEY PLAN2
AD101
987654321
987654321
A
B
C
D
E
F
A
B
C
D
E
F
Revisions: Date
Drawing Title
COR - STEPHEN WIGHTMAN
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project NumberCONSULTANTS: ARCHITECT/ENGINEERS:
Approved: Project Director
Office of Construction and Facilities
Management
BATH VA MEDICAL CENTER
76 VETERANS AVE.
BATH,NY 14810
08/01/2018 RAD GLG-AS-CCC
B-24
TRM DESIGN & PLANNING LLC
448 DELAWARE AVE. SUITE 202
BUFFALO, NEW YORK 14202
P: 716.946.9092
C&S COMPANIES
150 STATE STREET
SUITE 120
ROCHESTER, NEW YORK 14614
P: 585.325.9040
60% REVIEW PHASE
FLOOR PLAN AND ELEVATIONS-
NEW WORK
A101
528-A6-18-616
9/7/18
90% REVIEW PHASE 10/9/18
FINAL 11/26/18
R
PROPOSED SCALE: 1/2"=1'-0"
FLOOR PLAN1
A102
A102
2' -1
1/ 2"
2' -1
5'-2"± 7'-8"
5'-0" 2'-93/8" 3'-7"
CLR.
1'-0" 2'-0"
1'-47/8"
CLR.
21/2"
12'-101/2"
6' -6
5/ 8"
35/ 8"
5' -9
3/ 4"
3'-7"
CLR.
A102
A
B
C
D A101
E
F
G
H A101
I A101
NEW 3 5/8" METAL STUDS
@ 16" O.C W/ 5/8" TILE BACKER
BOARD TO UNDERSIDE OF
PLATFORM ABOVE
NEW 42" MIN. WOOD
DOOR & H.M FRAME (TYP.)
NEW 2 1/2" METAL STUDS
@ 16" O.C W/ 5/8" TILE
BACKER BOARD
EXIST. WINDOWS TO
REMAIN (TYP.)
EXISTING
CANDY
VENDING
MACHINE
EXISTING
BOTTLE
VENDING
MACHINE
EXISTING
BOTTLE
VENDING
MACHINE
EXISTING WALL TO REMAIN
EXIST. ACCESS TO ATTIC
SPACE IN CEILING
EXISTING
CANDY
VENDING
MACHINE
EXISTING
BOTTLE
VENDING
MACHINE
EXISTING
BOTTLE
VENDING
MACHINE
EXIST. VENT PIPE TO BE
REWORKED
NEW 42" MIN. WOOD
DOOR & H.M FRAME (TYP.)
NEW PUSH PLATE SWITCH (TYP.)
EXIST. WINDOWS TO
REMAIN (TYP.)
NEW ADA COMPLIANT FLOOR
MOUNTED WATER CLOSET
(SEE MEP DWGS.)
NEW GRAB BARS (TYP.)
NEW TOILET ROOM
ACCESSORIES TO BE SELECTED
BY VAMC, INSTALLED BY GC
(TYP.)
NEW WALL MOUNTED LAVATORY
NEW EXHAUST DUCT ( ABOVE
CLG ); SEE MEP DWGS.
NEW 3 5/8" METAL STUDS @ 16" O.C
INFILL W/ 5/8" GYP. BOARD & 5/8"
TILE BACKER BOARD
105A
RESTROOM
UNISEX
105B
RESTROOM
UNISEX
1HA1
EXISTING CORRIDOR
@ RESTROOM 105A SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONA
ACT-1
B-1
5' -2
T.O. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
NEW ACOUSTICAL
CEILING TILE & GRID
NEW STUD INFILL @
EXISTING RECESSED
WINDOW
T.O EXIST. SILL
2'-8"±
DOOR ACTUATOR
PUSH PLATE
SWITCH
NEW TILE SILL
NEW WALL MOUNTED
STEAM HEATER (SEE
MECH DWGS.)
PUSH TO
LOCK SWITCH
PT-1
WT-1
WT-2
WT-3
@ RESTROOM 105A SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONB
ACT-1
B-1
PT-1
WT-1
WT-2
WT-3
PT-3
2' -1
0"
TO
P
O F
LA
VA
TO
RY
T.O. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
NEW 42" WIDE
WOOD DOOR.
H.M. FRAME NEW WALL
MOUNTED
LAVATORY (SEE
PLUMBING
DWGS.)
NEW ACOUSTICAL
CEILING TILE & GRID
PROVIDE PIPE
COVER (SEE
PLUMBING DWGS.)
NEW AUTOMATIC
DOOR OPERATOR
KICKPLATE
@ RESTROOM 105A SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONC
ACT-1
B-1 2'
-1 0"
M
AX
3' -4
" M
AX
4' -0
" M
AX
24"
MIN.
12"
MIN
1'-47/8"
3' -0
-1
9"
3'-0"
1' -2
38 11
TO
P
O F
LA
VA
TO
RY
FR
. F
IN
. T
O B
O
TT
O M
O F
RE
FL
EC
TIV
E
SU
RF
AC
E
T.O. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
NEW ACOUSTICAL CEILING TILE & GRID
NEW ADA COMPLIANT
FLOOR MOUNTED
WATERCLOSET (SEE
PLUMBING DWGS.)
NEW WALL MOUNTED
LAVATORY
F.
F.
T O
B O
TT
O
M O
F D
IS
PE
N
SE
R
(F R.
F
IN
. F
LR
. T O
T.O G
RA
B
BA
R)
NEW TOILET
ACCESSORIES TO BE
SELECTED BY VAMC &
INSTALLED BY
CONTRACTOR (TYP.)
(FR. FIN. WALL
TO C OF
WATER CLOSET)
PROVIDE PIPE
COVER (SEE
PLUMBING DWGS.)
FULL HT.
FIRE ALARM NOTIFICATION APPLIANCE (SEE ELECT. DWGS.)
NEW LIGHT FIXTURE (SEE ELECT. DWGS.)
OUTSIDE CORNERS OR CERAMIC
TILE SHALL RECEIVE BRUSHED ST.
STL. TILE ACCESSORY (EQUIV. TO
SCHULTER " RONDEC" IN
APPROPRIATE SIZE TO MATCH TILE)
WT-1
PT-1
WT-1
WT-2
WT-3
6' -9
L
@ RESTROOM 105A SCALE: 3/8"=1'-0"
INTERIOR ELEVATIOND
ACT-1
B-1
WT-1
PT-1
WT-2
WT-3
WS-1
3' -0
-1
9" M
AX
" M
IN
.8"
5' -2
W
AL
L
FU
RR
IN
G
3'-4"
5' -0
1/ 2"
(F R.
F
IN
. F
LR
. T O
T.O G
RA
B
BA
R)
T.O. CLG. HT.
+8'-41/2"±
EXIST. F.F.
0'-0"
NEW ADA COMPLIANT
FLOOR MOUNTED
WATER CLOSET
EXIST. WINDOW TO REMAIN
NEW WALL FURRING
(SEE FLR. PLAN)
NEW GRAB BARS
NEW ACOUSTICAL
CEILING TILE & GRID
T.O EXIST. SILL
2'-8"±
NEW WALL MOUNTED STEAM
HEATER (SEE MECH DWGS.)
OUTSIDE CORNERS OR CERAMIC
TILE SHALL RECEIVE BRUSHED ST.
STL. TILE ACCESSORY ( EQUIV. TO
SCHULTER " RONDEC" IN
APPROPRIATE SIZE TO MATCH TILE )
18"x12" EXHAUST LOUVER W/
BIRDSCREEN CUT INTO EXIST.
WINDOW PANEL LITE
NEW WINDOW SHADE(S);
SECURELY ATTACH TO
WALL- V.I.F. EXG.
CONDTIONS WIDTH
(F R.
F
IN
. F
LR
. T O
T.O G
RA
B
BA
R)
8" 4'-0"±
VERIFY IN FIELD
@ RESTROOM 105B SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONG
ACT-1
B-1
5' -2
2' -9
5' -2
6" 4'
-0
4" 4"
T.O. CLG. HT.
+8'-41/2" ±
F.F.
0'-0"
NEW ACOUSTICAL CEILING TILE & GRID
DOOR ACTUATOR
PUSH PLATE SWITCH
(F R.
F
IN
. F
LR
. T O
SH
EL
F)
NEW WALL MOUNTED BABY
CHANGING STATION TO BE
SELECTED BY VAMC
NEW WALL
MOUNTED STEAM
HEATER
(SEE MECH. DWGS.)
FIRE ALARM
NOTIFICATION
APPLIANCE
(SEE ELECT. DWGS.)
(F R.
F
IN
. F
LR
. T O
FI
XT
UR
E)
OUTSIDE CORNERS OR CERAMIC TILE SHALL RECEIVE BRUSHED ST. STL. TILE ACCESSORY
( EQUIV. TO SCHULTER " RONDEC" IN APPROPRIATE SIZE TO MATCH TILE )
PUSH TO LOCK
SWITCH
PT-1
WT-1
WT-2
WT-3
@ RESTROOM 105B SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONF
ACT-1
B-1
PT-1
WT-1
WT-2
WT-3
PT-3
2' -1
0" M
AX
TO
P
O F
LA
VA
TO
RY
T.O. CLG. HT.
+8'-41/2"±
F.F.
0'-0"
NEW WALL MOUNTED
LAVATORY (SEE PLUMBING
DWGS.)
NEW ACOUSTICAL
CEILING TILE & GRID
NEW 42" WIDE WOOD
DOOR. H.M. FRAME
PROVIDE PIPE COVER
(SEE PLUMBING DWGS.)
NEW FULL HEIGHT
PARTITION (SEE FLR. PLAN)
NEW AUTOMATIC
DOOR OPERATOR
KICKPLATE
@ RESTROOM 105B SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONE
ACT-1
B-1
WT-1
PT-1
WT-2
WT-3
WT-1 3'-0" MIN.
1'-0"
MIN.
2'-0"
MIN.
-1
9"
3' -0
3' -4
" M
AX
" M
AX
. 48
1'-47/8"
NEW FULL HEIGHT PARTITION
(SEE FLR. PLAN)
6' -9
1' -2
TO
P
O F
LA
VA
TO
RY
(FR. FIN. WALL
TO C OF
WATER CLOSET)
F.
F.
T O
B O
TT
O
M O
F
RE
FL
EC
TIV
E
SU
RF
AC
E
T.O. CLG. HT.
+8'-41/2"±
F.F.
0'-0"
NEW ACOUSTICAL
CEILING TILE & GRID
ADA COMPLIANT
FLOOR MOUNTED
WATER CLOSET
(F R.
F
IN
. F
LR
. T O
T.O G
RA
B
BA
R)
F.
F.
T O
B O
TT
O
M O
F D
IS
PE
N
SE
R
PROVIDE PIPE
COVER (SEE
PLUMBING DWGS.)
NEW
ACCESSORIES TO
BE SELECTED BY
VAMC & INSTALLED
BY CONTRACTOR
NEW TILE SILL
TRAP PRIMER
ACCESS PRIMER (SEE
PLUMBING DWGS.)
NEW LIGHT FIXTURE
(SEE ELECT. DWGS.)
OUTSIDE CORNERS OR CERAMIC TILE SHALL
RECEIVE BRUSHED ST. STL. TILE ACCESSORY
( EQUIV. TO SCHULTER " RONDEC" IN
APPROPRIATE SIZE TO MATCH TILE )
L
@ RESTROOM 105B SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONH
ACT-1
B-1
PT-1
WT-3
WT-2
WT-1
A102
WS-1
3' -0
-1
9"
" M
IN
. 8"
4'-0"±
VERIFY IN FIELD
7"
5' -2
3'-4"
5' -0
1/ 2"
(F R.
F
IN
. F
LR
. T O
T.O G
RA
B
BA
R)
T.O. CLG. HT.
+8'-41/2"±
F.F.
0'-0"
NEW ADA COMPLIANT
FLOOR MOUNTED
WATERCLOSET
EXIST. WINDOW
TO REMAIN
NEW WALL FURRING
(SEE FLR. PLAN)
NEW ACOUSTICAL
CEILING TILE & GRID
T.O. EXIST. SILL
+2'-8"±
NEW WALL MOUNTED
STEAM HEATER (SEE
MECH DWGS.)
OUTSIDE CORNERS OR CERAMIC TILE SHALL RECEIVE
BRUSHED ST. STL. TILE ACCESSORY (EQUIV. TO SCHULTER
" RONDEC" IN APPROPRIATE SIZE TO MATCH TILE)
NEW WINDOW
SHADE(S); SECURELY
ATTACH TO WALL- V.I.F.
EXG. CONDTIONS
WIDTH
(F R.
F
IN
. F
LR
. T O
T.O G
RA
B
BA
R)
GENERAL FLOOR PLAN NOTES
1. FIELD VERIFICATION:
ALL CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL FIELD DIMENSIONS
AND EXISTING CONDITIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT
IMMEDIATELY OF ANY EXISTING CONDITIONS THAT VARIES FROM THE PLANS WITHIN
THIS SET. THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL EXISTING UTILITES IN
AREAS OF NEW CONSTRUCTION PRIOR TO COMMENCING WORK. THE
CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL UTILITIES AND ALL UTILITY
AGENCIES PRIOR TO COMMENCING WORK. LAYOUT ALL PARTITIONS IN FIELD PRIOR
TO ANY ERECTION & /OR FABRICATION & NOTIFY ARCHITECT OF ANY
DISCREPANCIES.
2. DIMENSIONS:
ALL DIMENSIONS ARE TO THE CENTERLINE OF COLUMNS, TO FACE OF STUDS, THE FACE OF
MASONRY OR THE FACE OF EXISTING CONSTRUCTION UNLESS OTHERWISE NOTED.
3. DEMOLITION:
REFER TO DEMOLITION (AD101) DRAWING FOR CONSTRUCTION TO BE REMOVED.
4. TRADE COORDINATION:
THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK WITH THAT OF
ALL OTHER TRADES. CONTRACTOR SHALL COORDINATE THE PERFORMANCE AND
SEQUENCING OF THE WORK WITH THE VA.
5. QUALITY:
GENERAL CONTRACTOR IS RESPONSIBLE FOR PROPER FIELD FITTING AND QUALITY OF
WORK OF ALL TRADES CONTRACTED TO PREFORM WORK. ALL TRADES SHALL TAKE
FIELD MEASUREMENTS AS REQUIRED AND BE RESPONSIBLE FOR FITTING NEW
CONSTRUCTION TO EXISTING CONSTRUCTION. CONTRACTORS SHALL REPAIR ANY
EXISTING CONSTRUCTION DISTURBED OR DAMAGED TO MATCH EXISTING
CONDITIONS.
6. EQUIPMENT REMOVAL:
COORDINATE WITH THE VA THE EXTENT OF DEMOLITION, RELOCATION AND/OR REMOVAL
OF EXISTING EQUIPMENT.
7. COORDINATION WITH OTHER PROJECTS:
IT IS THE CONTRACTOR'S RESPONSIBILITY TO EXAMINE ALL DRAWINGS AND SPECIFICATIONS
AND COORDINATE WORK WITH ALL OTHER CONTRACTS OCCURING ON VA
PROPERTY.
8. HAZARDOUS MATERIALS:
IF THE CONTRACTOR SUSPECTS THAT HE OR SHE HAS DISCOVERED HAZARDOUS MATERIALS
IN THE COURSE OF THEIR WORK THEY SHALL IMMEDIATELY NOTIFY THE OWNER'S
REPRESENTATIVE BEFORE PROCEEDING WITH THE WORK.
9. FINISHES:
SEE ROOM FINISH SCHEDULE & INTERIOR ELEVATIONS FOR INTERIOR FINISHES/
MATERIALS.
10. M/E/P COORDINATION:
PLUMBING FIXTURES, FLOOR DRAINS, CLEANOUTS, ETC. ARE SHOWN FOR
REFERENCE ONLY. REFER TO M/E/P DRAWINGS FOR ADDITIONAL INFORMATION,
INCLUDING VERIFICATION OF SIZE & LOCATIONS OF ALL EQUIPMENT.
11. DISRUPTIVE CONSTRUCTION:
SHALL ONLY OCCUR DURING HOURS APPROVED BY VAMC.
LOBBY
DINING ROOM
SEE DWG. E-49
(3)4"C
(1)4"C.,(2)1 1/2"FD
TO BUILDING 104
SEE NOTE 2
30" X 36" X 12"
PULL BOX
ELECT. CLOS.
24 SF
P1 V72
95 SF
D49, D50
OFFICE
81SF
1SW2
V49, V50
D N
105C
41 SF
E.M.S.
C
C O R R
ID
O R
D47, D48 V47, V4824
93 SF
STORAGE
256 SF
CLINICAL
DIETITIAN
D45, D46 V45, V46
349 SF
4"C
V43, V44
D43, D44N&FS
OFFICE
D41, D42 V41, V42
196 SF
OFFICE
S F
H A
C
CLEAN DISH AREA
74 SF
540 SF
WASH
110A
CART
275 SF
HOSP TRAY LINE
111B
MACHINE ROOM
738 SF
110B
228 SF
111A
VEST.
229 SF
REFRIG.
1810 SF
MAIN KITCHEN
4370 SF
D21, D22 V21, V22
TRASH ROOM
142 SF
160 SF
393 SF
REF'G
CORRIDOR
D19, D20 V19, V20
56 SF
1SW1
261 SF1HA3
REF'G
DN.
49 SF
FREIGHT
ELEV.
V39, V40 D39, D40
V37, V38 D37, D38
79 SF
105B
C
MEN'S RESTROOM
105A
69 SF
307 SF
106A
107A
TOILET
39 SF
D29, D30
NUTRITION
CLINIC
266 SF
OFFICE
DIETITIAN
D31, D32 V31, V32
H A
C O R R
ID
O R C V35, V36
D35, D36
S F
555 SF
V29, V3015
LOUVER
MOTORIZED
187 SF
VESTIBULE
245 SF
REF'G #1
D27, D28 V27, V28
D23, D24 V23, V24
12 V25, V26 D25, D26
164 SF
108A
SPVR. OFFICE
POTS & PANS
WASH AREA
478 SF
D13, D14 V13, V14
ELEV.
D15, D16 V15, V16
1317 SF
INGREDIENT ROOM
118A
234 SF
REF'G #3
305 SF
118B
REF'G #2
725 SF
RETHERM ROOM
EXISTING AC
SPLIT SYSTEM
A C
A C
A C
A C
AC
MANAGER
N&FS
USED FOR DATA
LOBBY
DINING ROOM
SEE DWG. E-49
(3)4"C
(1)4"C.,(2)1 1/2"FD
TO BUILDING 104
SEE NOTE 2
30" X 36" X 12"
PULL BOX
ELECT. CLOS.
24 SF
P1 V72
95 SF
D49, D50
OFFICE
81SF
1SW2
V49, V50
D N
105C
41 SF
E.M.S.
C
C O R R
ID
O R
D47, D48 V47, V4824
93 SF
STORAGE
256 SF
CLINICAL
DIETITIAN
D45, D46 V45, V46
349 SF
4"C
V43, V44
D43, D44N&FS
OFFICE
D41, D42 V41, V42
196 SF
OFFICE
S F
H A
C
CLEAN DISH AREA
74 SF
540 SF
WASH
110A
CART
275 SF
HOSP TRAY LINE
111B
MACHINE ROOM
738 SF
110B
228 SF
111A
VEST.
229 SF
REFRIG.
1810 SF
MAIN KITCHEN
4370 SF
D21, D22 V21, V22
TRASH ROOM
142 SF
160 SF
393 SF
REF'G
CORRIDOR
D19, D20 V19, V20
56 SF
1SW1
261 SF1HA3
REF'G
DN.
49 SF
FREIGHT
ELEV.
V39, V40 D39, D40
V37, V38 D37, D38
79 SF
105B
C
105A
69 SF
LADIE'S RESTROOM
307 SF
106A
107A
TOILET
39 SF
D29, D30
V33, V34 D33, D34
266 SF
D31, D32 V31, V32
H A
C O R R
ID
O R C V35, V36
D35, D36
S F
MAIL ROOM
555 SF
V29, V3015
LOUVER
MOTORIZED
187 SF
VESTIBULE
245 SF
REF'G #1
D27, D28 V27, V28
D23, D24 V23, V24
12 V25, V26 D25, D26
164 SF
108A
SPVR. OFFICE
POTS & PANS
WASH AREA
478 SF
D13, D14 V13, V14
ELEV.
D15, D16 V15, V16
1317 SF
INGREDIENT ROOM
118A
234 SF
REF'G #3
305 SF
118B
REF'G #2
725 SF
RETHERM ROOM
EXISTING AC
SPLIT SYSTEM
A C
A C
A C
A C
AC
MANAGER
N&FS
CWT
USED FOR DATA
DOOR NUMBER
(SEE DOOR SCHEDULE)
WALL TYPE
(SEE WALL TYPE SCHEDULE)
NEW OR RELOCATED DOOR
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE REMOVED
WINDOW TYPES
(SEE WINDOW TYPES)
NEW WALL AND/OR PATCH TO
MATCH EXG. ADJACENT
EXIST. CONSTRUCTION
TO REMAIN
EXIST. CONSTRUCTION
TO BE REMOVED
FIRE EXTINGUISHER
FLOOR PLAN LEGEND
24"x36" MIRROR
SEE PLUMBING
DWGS.
SEE PLUMBING
DWGS.
36" GRAB BAR
TOILET PAPER
DISPENSER
C.F.C.I
C.F.C.I
CUSTOM LENGTH
WATERCLOSET
O.F.C.I
SOAP DISPENSER
BABY CHANGING
STATION
SINK
TOILET ACCESSORY SCHEDULE
REMARKS MODEL NO.MARK ITEM
SEE NOTE 1& 2
PROVIDE ALL REQUIRED WALL BLOCKING
TO MOUNT RESTROOM ACCESSORIES.
WALL BLOCKING SHALL BE FIRE RETARDANT
TREATED OR SHEET METAL BACKING
1.
NOTES:
2.
SEE NOTE 1& 2
C.F.C.I = CONTRACTOR FURNISHED
CONTRACTOR INSTALLED.
O.F.C.I = OWNER FURNISHED
CONTRACTOR INSTALLED.
O.F.O.I = OWNER FURNISHED
OWNER INSTALLED.
CHILD
PROTECTION SEAT
PAPER TOWEL
DISPENSER
O.F.C.I SEE NOTE 1& 2
O.F.C.I
C.F.C.I
O.F.C.I SEE NOTE 1& 2
SEE NOTE 1
SEE NOTE 1
SEE NOTE 1
O.F.C.I SEE NOTE 1& 2
SANITARY NAPKIN
DISPOSAL
O.F.C.I SEE NOTE 1& 2
SANITARY NAPKIN
VENDOR
O.F.C.I SEE NOTE 1& 2
@ EXIST. CORRIDOR SCALE: 3/8"=1'-0"
INTERIOR ELEVATIONI
PT-3
3' -0
5' -0
EXTENT OF NEW PAINT
(INSIDE CORNER TO OUTSIDE CORNER)
02 01
NEW 42" WIDE
WOOD DOOR.
H.M. FRAME
NEW PUSH PLATE
SWITCH (TYP.)
NEW ADA COMPLIANT
RESTROOM SIGNAGE
(SEE SPECS.)
T.O. CLG. HT.
EXIST.
F.F.
0'-0"
EXIST. WALL BASE TO
REMAIN & BE MODIFIED
AS REQUIRED PER NEW
DRAWINGS
OCCUPANCY
INDICATOR (TYP.)
PT-2
35/8" 5/8"
41/4"
21/2" 5/8"
35/8" METAL STUDS @ 16" O.C. PROVIDE 5/8" TILE
BACKER BOARD ON ONE SIDE WHERE WALL TILE
IS USED. (PROVIDE 5/8" TYPE 'X' GYP. BD. WHERE
PAINTED)
1.) **NEW 5/8" T.B.B OR 5/8" TYPE 'X' GYP. BD. TO BE INSTALLED ON
EXISTING WALLS THAT SHALL HAVE SUBSTRATE REMOVED (SEE
DEMOLITION PLAN)
2.) FIRE BLOCKING TO BE INSTALLED HORIZ. BETWEEN STUDS AT
HEIGHT CORRESPONDING TO A.C.T. HT. IN ROOM.
3.) MOISTURE RESISTANT GYP. BD. SHALL BE USED AT ALL TOILET
ROOM LOCATIONS WHERE THE FINISH IS INTENDED TO BE PAINTED
GYP. BD.
4.) REFER TO FINISH SCHEDULE , FLOOR PLANS, INTERIOR
ELEVATIONS & SPECIFICATIONS FOR ALL FINISHES OR OTHER
VARIATIONS IN MATERIAL.
5.) REFER TO ALL DRAWINGS (PLANS, SECTIONS, DETAILS, ETC.) TO
DETERMINE VARIATIONS IN WALL TYPES.
6.) REFER TO MECHANICAL/ ELECTRICAL/ PLUMBING DRAWINGS
FOR ADDITIONAL INFORMATION AND COORDINATION OF
EQUIPMENT AND INSTALLATIONS.
WALL KEY WALL DESCRIPTION
NOTES
21/2" METAL STUDS @ 16" O.C. (SEE INTERIOR
ELEVATIONS FOR HEIGHT) PROVIDE 5/8" TILE BACKER
BOARD ON ONE SIDE WHERE WALL TILE IS USED.
(PROVIDE 5/8" TYPE 'X' GYP. BD. WHERE PAINTED)
WALL TYPES
FIRST FLOOR OF B-24 BLDG. SCALE: N.T.S.
KEY PLAN2
A101
NOTE: SEE SHEET A102 FOR FINISH SCHEDULE
STAMP
987654321
987654321
A
B
C
D
E
F
A
B
C
D
E
F
Revisions: Date
Drawing Title
COR - STEPHEN WIGHTMAN
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project NumberCONSULTANTS: ARCHITECT / ENGINEERS:
Approved: Project Director
Office of Construction and Facilities
Management
BATH VA MEDICAL CENTER
76 VETERANS AVE.
BATH,NY 14810
08/01/2018 RAD GLG-AS-CCC
B-24
TRM DESIGN & PLANNING LLC
448 DELAWARE AVE. SUITE 202
BUFFALO, NEW YORK 14202
P: 716.946.9092
C&S COMPANIES
150 STATE STREET
SUITE 120
ROCHESTER, NEW YORK 14614
P: 585.325.9040
60% REVIEW PHASE
FINISH PLANS ,SCHEDULES &
DETAILS
A102
528-A6-18-616
9/7/18
90% REVIEW PHASE 10/9/18
FINAL 11/26/18
R
ACT-1
ACT-1
OS
OS
WS-1
EXISTING CEILING TO REMAIN
EXISTING ACCESS TO ATTIC
NEW 2'x2' ACOUSTICAL CEILING
TILE & T-GRID SYSTEM
NEW LIGHT FIXTURE
(SEE MEP DWGS.)
SPRINKLER HEAD (SEE FIRE
PROTECTION DWGS.)
NEW EXHAUST VENT
(SEE MECH DWGS.)
NEW LIGHT FIXTURE
(SEE MEP DWGS.)
CLG. HT.=
8'-4 1/2" A.F.F
CLG. HT.=
8'-4 1/2" A.F.F
NEW OCCUPYING SENSORS
NEW WINDOW SHADE(S);
SECURELY ATTACH TO WALL-
V.I.F. EXG. CONDTIONS
WIDTH
105A
RESTROOM
UNISEX
105B
RESTROOM
UNISEX
1HA1
EXISTING CORRIDOR
PROPOSED SCALE: 1/2"=1'-0"
REFLECTED CEILING PLAN1
FT-1
FT-1
FT-2
3C A102
3C A102
FT-2
FT-1
FT-2
FT-1
1' -0
FU
LL
T
IL
ES
1'
-0
1'-0" 9 FULL TILES 1'-0"
1' -0
FU
LL
T
IL
ES
1'
-0
1'-0" 9 FULL TILES 1'-0"
NEW THRESHOLD-SEE DTL.
(TYP.)
NEW FLOOR DRAIN (SEE
PLUMBING DWGS.)
NEW FLOOR TILE TO BE INSTALLED
OVER WATERPROOF/ ANTI-
FRACTURE MEMBRANE SYSTEM
(TYP.) (SEE SPECS.)
NEW FLOOR WATERPROOF/ ANTI-
FRACTURE MEMBRANE SYSTEM TO
WRAP UP WALL UP & UNDER NEW
WALL TILE (8" MIN.) (TYP.)
CUT FIELD TILE AT
PERIMETER
ACCENT TILE
NOTE:
CONTRACTOR TO REFERENCE TCNA
INSTALLATION METHOD F1AA-17
NOTE:
A. IT IS ASSUMED THAT 50% OF THE
WOOD PLANK SUBFLOOR WILL REQUIRE
REMOVAL & REINSTALLATION OF NEW
PLANK & PLYWOOD ON THE EXISTING
FRAMING.
B. BOTH RESTROOMS SHALL RECEIVE
NEW 1/4" FIBER CEMENT BACKER
BOARD OVER THE EXISTING SUBFLOOR.
C. BOTH RESTROOMS SHALL RECEIVE
LIQUID APPLIED LOAD BEARING
WATERPROOF CRACK ISOLATION
MEMBRANE ( EQUIV. TO LATICRETE
"HYDROBAN" SYSTEM AS PER MANUF.
SPECS )
D. SEE DETAIL 3C THIS SHEET.
ACCENT TILE
CUT FIELD TILE AT
PERIMETER
105A
RESTROOM
UNISEX
105B
RESTROOM
UNISEX
1HA1
EXISTING CORRIDOR
PROPOSED SCALE: 1/2"=1'-0"
FLOOR FINISH PLAN2
B-1
PT-1
PT-2
FT-2
ACT-1
WT-1
WT-2
WT-3
PT-4
FT-1
WS-1
PT-3
T-1
DESCRIPT IONK EY
WALL BASE: COVE BASE (6"x12") & SPECIAL CORNERS
MANUF: CROSSVILLE (EMPIRE SERIES)
COLOR: PALAIS TAUPE; VS81 ( UNPOLISHED )
PAINT: ( @ WALLS & PARTITIONS )
COLOR: SW6116 " TATAMI TAN"
FINISH: SEMI-GLOSS
KEY TO FINISHES
PAINT COLOR AND FINISH TO MATCH ADJACENT WALL @ CORRIDOR
( SUBMIT SAMPLE SELECTION TO VAMC C.O.R.
ACOUSTICAL CEILING TILE:
MANUF.: ARMSTRONG #584B
SIZE: 24" x 24" WITH 15/16" T-GRID SYSTEM
COLOR: WHITE
WALL TILE: ( FIELD TILE )
MANUF.: CROSSVILLE
STYLE: EMPIRE SERIES
SIZE: 12" x 12"
COLOR: PALAIS TAUPE; VS81 ( UNPOLISHED )
WALL TILE: ( ACCENT TILE )
MANUF.: CROSSVILLE
STYLE: GLASS BLOX- INSTALL ON WHITE THINSET & FACE FLUSH W/ WT-1
SIZE: 1"x1"
COLOR: TAUPE FOG #G070
WALL TILE: ( FIELD TILE )
MANUF.: CROSSVILLE
STYLE: EMPIRE
SIZE: 4"x12" BULLNOSE
COLOR: PALAIS TAUPE; VS81 (UNPOLISHED )
GENERA L FINISH NOT ES
1. APPLY ALL PAINT WITH MINIMUM 1 COAT PRIMER & 2 FINISH COATS.
2. ALL PAINT FINISHES TO BE SEMI-GLOSS WHERE APPLIED TO PLASTER & GYP. BD. AND
GLOSS @ STEEL.
3. ENSURE ALL EXISTING SUBSTRATES TO RECEIVE NEW FINISHES ARE PROPERLY PREPARED
PER MANUFACTURER'S SPECIFICATIONS TO ALLOW PROPER ADHESION.
4. PAINT SHALL BE MIXED BY VAMC PAINTERS WITH VAMC MACHINE. SHERWIN WILLIAMS
HARMONY SEMI-GLOSS ONLY. CONTRACTORS TO SUPPLY THE PAINT BASE ONLY.
FLOOR TILE: ( FIELD TILE )
MANUF: CROSSVILLE (EMPIRE SERIES)
SIZE:12" x 12"
COLOR: PALAIS TAUPE; VS81 (UNPOLISHED)
FLOOR TILE: ( ACCENT TILE )
MANUF: CROSSVILLE (EMPIRE SERIES)
SIZE:12" x 12"
COLOR: MARQUIS GREIGE; VS83 ( UNPOLISHED )
WINDOW SHADE:
MANUF.: ALTEX SUN PROJECT LINE, DEKO S-70, SQUARE CASSETTE,
LITE LIFT SHADES, ECO SCREEN
SIZE: VERIFY IN FIELD WIDTH OF WINDOW
COLOR: ES-8504P
PAINT: ( @ H.M. FRAME )
COLOR: SW7690 "TOWN HALL TAN"
FINISH: SEMI-GLOSS
PAINT COLOR AND FINISH TO MATCH EXISTING WINDOWS
( SUBMIT SAMPLE SELECTION TO VAMC C.O.R. )
THRESHOLD: ( RUBBER )
MANUF.: JOHNSONITE
STYLE: WHEELED TRAFFIC TRANSITIONS "CTA-XXX-Q"
SIZE: VERIFY IN FIELD WIDTH OF DOOR OPENING
COLOR: ( BEIGE TO MATCH NEW FLOORING: SUBMIT
SAMPLE SELECTION TO VAMC C.O.R. )
GROUT: "ARDEX FL" RAPID SET
FLEXIBLE SANDED GROUT.
COLOR: " GREY DUSK -15"
GROUT: "ARDEX FL" RAPID SET FLEXIBLE SANDED GROUT.
COLOR: " VINTAGE LINEN-08"
GROUT: "ARDEX FL" RAPID SET FLEXIBLE
SANDED GROUT.
COLOR: " VINTAGE LINEN-08"
GROUT: "ARDEX FL" RAPID SET FLEXIBLE
SANDED GROUT.
COLOR: " VINTAGE LINEN-08"
GROUT: "ARDEX FL" RAPID SET
FLEXIBLE SANDED GROUT.
COLOR: " GREY DUSK -15"
GROUT: "ARDEX FL" RAPID SET
FLEXIBLE SANDED GROUT.
COLOR: " GREY DUSK -15"
DOOR SCHEDULE
ID
DOOR
W.
3'-6"
3'-6"
H.
7'-0"
7'-0"
THK.
13/4"
13/4"
MAT.
WOOD
WOOD
FIN.
ST. & CL.
ST. & CL.
GLAZING
RATING
60 min
60 min
HW
GRP
TYPE
A
A
FRAME
MAT.
H.M.
H.M.
FIN.
PT.
PT.
DETAILS
HEAD
3A
3A
JAMB
3B
3B
SILL
3C
3C
REMARKS
DOOR FINISH TO MATCH ADJACENT NEW CAFETERIA DOORS
DOOR FINISH TO MATCH ADJACENT NEW CAFETERIA DOORS
A
SCALE: 1/4"=1'-0"
DOOR FRAMES
F-1
SCALE: 1/4"=1'-0"
DOOR TYPES
2" W.O.D 2"
HOLLOW METAL FRAME
(PAINTED)SOLID CORE WOOD
DOOR (STAIN W/
CLEAR COATING)
(SEE SPECS.)
@ PLUMBING PARTITION SCALE: 1"=1'-0"
SECTION5
105A
RESTROOM
UNISEX
105B
RESTROOM
UNISEX
8' -4
1/ 2"
EXISTING STUD WALL TO
REMAIN, REMOVE EXISTING
SUBSTRATE BOTH SIDES (TYP.)
NEW 3 5/8" METAL STUDS
@ 16" O.C (SEE SPECS.)
5/8" TILE BACKER BOARD
UP TO UNDERSIDE OF
PLATFORM (ABOVE)
NEW ACOUSTICAL
CEILING TILE & GRID
EXISTING SUBFLOOR
TO REMAIN
NEW FLOOR FINISH
NEW WALL TILE (SEE
INTERIOR ELEVATIONS)
NEW WALL TILE (SEE
INTERIOR ELEVATIONS)
LAG BOLTS (TYP.)
NEW WALL BASE
(SEE INTERIOR
ELEVATIONS)
5/8" TILE BACKER
BOARD (SEE SPECS.)
EXTENT OF REMOVAL OF
EXISTING SUBSTRATE A MINIMUM
OF 2" ABOVE CEILING FINISH
EXIST. PLATFORM
EXIST. ATTIC SPACE
ATTACH PARTITION TRACK
TO EXIST. FRAMING
HM DOOR FRAMES SCALE: 3"=1'-0"
DETAIL
BA
C T-1
2" 1/
2"
2" 1/2"
1/ 2"
1/ 2"
EXG. WALL
1/2" 1/2"
1/ 4" M
AX
4"
21/4"± V.I.F.
EXIST. WALL
CONSTRUCTION
(V.I.F.)
JAMBHEAD
CAULK BOTH SIDES ALL AROUND
SOLID WOOD
DOOR SEE ROOM FINISH SCHEDULE &
INTERIOR ELEV. FOR FINISHES
HOLLOW METAL FRAME
(PAINT)W/ MIN. OF (4)
ANCHORS / JAMB
SEE WALL TYPES FOR FINISH
SEE WALL TYPES
FOR FINISH
EXIST. WALL CONSTRUCTION (V.I.F.)
HOLLOW METAL
FRAME (PAINT)
(SLOPE 1:12 MAX.)
NEW ADA COMPLIANT THRESHOLD ( EQUIV.
TO AS MANUF. BY JOHNSONITE- STYLE:
WHEELED TRAFFIC TRANSITIONS "CTA-XXX-Q" )
VIF: COORD. W/ ARCHITECT
EXISTING CORRIDOR FLOORING
( V.C.T.) TO REMAIN
TOP OF FIN. FL.
AT CORRIDOR
TOP OF FIN. FL.
@ RESTROOM
ASSUMED TOP OF
EXIST. WOOD PLANK FLOOR
( RESTROOM) (EXIST. CORRIDOR)
SILL
NEW C.T.- W/ THIN SET MORTAR
1/4" NEW FIBER CEMENT BD.
EXISTING WOOF PLANK FLOOR
NEW LIQUID APPLIED LOAD
BEARING WATERPROOFING
CRACK ISOLATION MEMBRANE
SLOPE
SELF-LEVELING BED AS REQUIRED FOR
INSTALLATION OF NEW THRESHOLD- VIF
GRAB BAR SUPPORT @ MTL. STUDS SCALE: 1 1/2"=1'-0"
DETAIL
11/2"
SECTION:B
GRAB
BAR
SE
E
EL
EV
AT
IO
N S
FO
R
M O
UN
TIN
G H
T.
VERTICAL GRAB BAR
PLAN:A
METAL STUD FRAMING-
REFER TO FLOOR PLAN
WINDOW SILL ( BELOW )
GRAB BAR
VERTICAL
GRAB BAR
EDGE OF
WINDOW
WINDOW SILL
B
B
DOOR HARDWARE SCHEDULE
RESTROOMS:
EACH DOOR TO HAVE
2.0 EA. HINGE BB1279 5 x 4 1/2 NRP US26D HA
1.0 EA. HINGE BB1279 5x4 1/2 ETW-4 NRP US26D HA
1.0 EA. ELECTRIFIED LOCKSET 3880EL SECT WTN SFIC7 US32D HA
1.0 EA. CYLINDER CORE 3982-C US26D HA
1.0 EA. ELECTRIC STRIKE 2930 MOR US32D HA
1.0 EA. POWER OPERATOR 8418 PUSH ALUM HA
1.0 EA. PROTECTION PLATE 190S 10" x 40" US32D HA
1.0 EA. WALL STOP 232W US32D HA
1.0 SET WEATHERSTRIP 726 x LAR S HA
1.0 EA. DOOR POSITION SWITCH 184-12 BLK GRIS
1.0 EA. OCCUPANCY LIGHT 10LEDSOUNDER US32D BEAU
2.0 EA. ACTUATOR PHSS1-US (HAND-E-TAP) ESSEX
1.0 EA. PUSH BUTTON PTLBUTTON US32D BEAU
1.0 EA. RELAY/ SEQUENCER 2-659-0240 HA
1.0 EA. POWER SUPPLY 2908 2-679-0661 HA
1.0 EA. WIRING DIAGRAM RISER/ POINT TO POINT BYOT
DESCRIPTION OF OPERATION:
1. THE DOOR IS NORMALLY CLOSED AND UNLOCKED.
2. PRESSING OUTSIDE ACTUATOR WILL RELEASE ELECTRIC STRIKE AND AUTOMATICALLY
OPEN THE DOOR.
3. PRESSING INSIDE ACTUATOR RELEASES ELECTRIC STRIKE, UNLOCKS OUTSIDE LEVER,
TURNS OFF INDICATOR LIGHT AND OPENS THE DOOR.
4. UPON LOSS OF POWER THE BATTERY BACKUP KEEPS DOOR LOCKED UNTIL MANUALLY
OPENED.
5. THE PUSH TO LOCK BUTTON (LOCATED IN RESTROOM) LOCKS THE DOOR AND
DISABLES THE OUTSIDE ACTUATOR.
6. THE DOOR POSITION SWITCH WILL UNLOCK THE OUTSIDE LEVER AND TURN OFF THE
OCCUPANCY INDICATOR IF THE DOOR IS OPENED MANUALLY.
HARDWARE GROUP 1
@ EXISTING WINDOW SILL SCALE: 3/4"=1'-0"
SECTION4
EXIST. F.F.
0'-0"
T.O EXIST. SILL
2'-8"±
T.O WALL TILE
5'-2"
NEW WALL TILE (SEE
INTERIOR ELEVATIONS)
FACE OF EXISTING
WINDOW TO REMAIN
EXISTING STONE WINDOW
SILL TO REMAIN
INSTALL NEW 5/8" TILE BACKER
BOARD OVER EXISTING SILL
NEW 2 1/2" METAL STUDS @
16" O.C W/ 5/8" TILE BACKER
BOARD ON ONE SIDE
EXIST. SUBFLOOR
DBL. 2x F.R.T WOOD
BLOCKING
NEW WALL BASE
NEW GRAB BAR
NEW WALL PAINT (SEE
INTERIOR ELEVATIONS) GRAB BAR @ EXIST. WINDOW SCALE: 1 1/2"=1'-0"
DETAIL6
105A
RESTROOM
UNISEX
105B
RESTROOM
UNISEX
7"
EXISTING WINDOW TO REMAIN
EXISTING EXTERIOR WALL TO REMAIN
NEW TILE SILL OVER
5/8" T.B.B (BELOW)
NEW DBL. 2x F.R.T
BLOCKING (CUT TO FIT)
5/8" T.B.B (SEE SPECS.)
NEW WALL TILE
EXISTING VENT PIPE TO BE
REWORKED (SEE PLUMBING DWGS.)
NEW GRAB BARNEW 2 1/2" MTL. STUDS @ 16" O.C
WALL (BELOW) W/ 5/8" T.B.B
NEW 2 1/2" METAL STUDS @
16" O.C WALL W/ 5/8" T.B.B
LINE OF EXISTING
SILL (BELOW)
BULLNOSE
CORNER
EXISTING SUBSTRATE ON BOTH SIDES TO BE REMOVED
DOWN TO FACE OF STUD, NEW 5/8" T.B.B OR 5/8" GYP.
BD. TO BE PROVIDED (SEE INTERIOR ELEVATIONS)
F.R.T BLOCKING
OR EQUIV.
CLG. HT. =
XX'-X" A.F.F.
HEIGHT OF CEILING
ABOVE FINISHED FLOOR
SUSPENDED ACOUSTICAL
CEILING SYSTEM (TYPE AND
HEIGHT AS NOTED ON DWGS.)
SUPPLY DIFFUSER
-SEE MECH. DWGS.
RETURN GRILL
-SEE MECH. DWGS.
NEW RECESSED LIGHT FIXTURE
FOR SUSPENDED CEILING GRID
-SEE ELEC. DWGS.
FLOOR PLAN LEGEND
SPRINKLER HEAD
-SEE FIRE PROTECTION DWGS.
| T100 |
| T100 COVER SHEET |
| HM101 |
| HM101 HAZARDOUS MATERIALS |
| ADA101 |
| ADA101 HC ACCESSIBILITY, ABBREVIATIONS & SYMBOLS |
| AD101 |
| AD101 FLOOR PLAN AND ELEVATIONS -DEMOLITION |
| A101 |
| A101 FLOOR PLAN AND ELEVATIONS- NEW WORK |
| A102 |
| A102 FINISH PLANS ,SCHEDULES & DETAILS |
| M001 |
| M101 |
| E101 |
| P001 |
| PD101 |
| P101 |
| F001 |
| F101 |