P01 Air Emissions List 2024.xlsx
XLSX spreadsheet 11 KB Posted
- Solicitation number
- 36C25025Q0410
About this file
The file is an Excel spreadsheet (P01 Air Emissions List 2024.xlsx) detailing a comprehensive inventory of fuel combustion devices and their greenhouse gas (GHG) emissions potential across multiple buildings. The inventory includes 21 devices spanning emergency generators, boilers, water heaters, and other equipment, with specifics such as device type, identifier, fuel type, and maximum design capacity. Devices are located in Buildings 3, 6, 9, 19, and 21, primarily using natural gas or diesel fuel, with capacities ranging from 40,000 Btu/hr to 750 kW.
The related federal contract opportunity is a pre-solicitation notice (Solicitation Number: 36C25025Q0410) for Air Emission Survey Inventory Services at the Aleda E. Lutz VA Medical Center in Saginaw, Michigan. The Department of Veterans Affairs intends to award a firm fixed-price contract under NAICS Code 541620, with a size standard of $19 million. The solicitation will be electronically issued on or about March 14, 2025, via SAM.gov, and requires potential bidders to be registered and active in the System for Award Management. No phone, fax, or email inquiries will be accepted for this pre-solicitation notice.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Approved DNRE Air permit 2010 79-10.pdf | ||
| Permit 206-10.pdf | ||
| 36C25025Q0410 0001.docx | DOCX document | |
| 36C25025Q0410.docx | DOCX document | |
| P07 WD No. 2015-4865 Rev. 26.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Facility Fuel Combustion GHG Worksheet | |||||
| Use this worksheet to collect basic information about the fuel combustion devices/ equipment that generate GHGs at your facility. This information will be useful to calculate the potential to emit (PTE) of Carbon Dioxide equivalent for each device then totaled at the bottom for a facility-wide PTE. | |||||
| 1) Device Type (boiler, generator, oven, dryer, water heater (WH), space heater, emergency generator, engines/ compressors, other fuel combustion devices such as heat treatment equipment | 2) Identifier (example, SN (S), Model # (M), EE#) | 3) Fuel combusted (natural gas, propane, fuel oil) | 4) Max Design Capacity (MMBtu/ hr, Btu/Hr, kW) found on nameplate of the unit | 5) Identified in an Air Permit? (No, Yes (enter permit number and limit) | |
| Emergency Generator 1, Build. 19 | S: B010204440 | Diesel | 400 kW | No/Exempt | |
| Emergency Generator 2, Build. 19 | S: 331914-1-1-0411 | Diesel | 400 kW | No/Exempt | |
| Emergency Generator 3, Build. 19 | S: G920477586 | Diesel | 350 kW | No/Exempt | |
| Emergency Generator E/C | S: 320019-1-1-0410 | Diesel | 750 kW | 79-10 | |
| Emergency Generator Build. 6 (REMOVED) | M: U6409448 | Diesel | 100 kW | No/Exempt | |
| Emergency Generator Build. 21 | M:16601001486 | Diesel | 500 kW | MDD-STNRCI-09-01 | |
| Emergency Generator Building 3 | M:GGHG-7090865 | ||||
| S: D08177283 | Nat. Gas | 85 kW | No/Exempt | ||
| Boiler 1 Building 6 (REMOVED) | M: CR200X250 | Nat. Gas | 10,461,000 Btu/hr | No/Exempt | |
| Boiler 2 Building 6 (REMOVED) | M: CR200X250 | Nat. Gas | 10,461,000 Btu/hr | No/Exempt | |
| Boiler 3 Building 6 (REMOVED) | M: 829401 | Nat. Gas | 6,276,600 Btu/hr | No/Exempt | |
| water heater Building 6 | M: MI40T6FBN | GAS | 40,000 Btu/hr | No/Exempt | |
| Domestic WH 1 E/C | S: G-10-0815 | GAS | 902,100 Btu/hr | No/Exempt | |
| Domestic WH 2 E/C | S: G-10-0817 | GAS | 902,100 Btu/hr | No/Exempt | |
| Domestic WH 3 E/C | S: G-10-0816 | GAS | 902,100 Btu/hr | No/Exempt | |
| Boiler 1 E/C | M: ZFC1100W | Nat. Gas | 10,353 MBtu/hr | 79-10 | |
| Boiler 2 E/C | M: ZFC1100W | Nat. Gas | 10,353 MBtu/hr | 79-10 | |
| Boiler 3 E/C | M: ZFC1100W | Nat. Gas | 10,353 MBtu/hr | 79-10 | |
| Water Heater Building 3 | M: PRN050G S:HH15479464 | GAS | 60,000 Btu/hr | No/Exempt | |
| Boiler 1 Building 3 | M: KBN800 S:KO9H10123618 | GAS | 746,400 Btu/hr | 79-10 | |
| Boiler 2 Building 3 | M: KBN800 S:KO9H10123082 | GAS | 746,400 Btu/hr | 79-10 | |
| Boiler 3 Building 3 | M: KBN800 S:KO9H10123625 | GAS | 746,400 Btu/hr | 79-10 | |
| Boiler 1 Building 9 | M: KBN600 S:KO9H10120172 | GAS | 559,000 Btu/hr | 79-10 | |
| Boiler 2 Building 9 | M: KBN600 S:KO9H10122548 | GAS | 559,000 Btu/hr | 79-10 | |
| Boiler 3 Building 9 | M: KBN600 S:KO9H10122554 | GAS | 559,000 Btu/hr | 79-10 | |
| Chapel roof preheater | M: PVF250H S:12285845 | GAS | 200,000 Btu/hr | No/Exempt |