The file is an Excel spreadsheet (P01 Air Emissions List 2024.xlsx) detailing a comprehensive inventory of fuel combustion devices and their greenhouse gas (GHG) emissions potential across multiple buildings. The inventory includes 21 devices spanning emergency generators, boilers, water heaters, and other equipment, with specifics such as device type, identifier, fuel type, and maximum design capacity. Devices are located in Buildings 3, 6, 9, 19, and 21, primarily using natural gas or diesel fuel, with capacities ranging from 40,000 Btu/hr to 750 kW.

The related federal contract opportunity is a pre-solicitation notice (Solicitation Number: 36C25025Q0410) for Air Emission Survey Inventory Services at the Aleda E. Lutz VA Medical Center in Saginaw, Michigan. The Department of Veterans Affairs intends to award a firm fixed-price contract under NAICS Code 541620, with a size standard of $19 million. The solicitation will be electronically issued on or about March 14, 2025, via SAM.gov, and requires potential bidders to be registered and active in the System for Award Management. No phone, fax, or email inquiries will be accepted for this pre-solicitation notice.

View the file

Other files

File Type Posted
Approved DNRE Air permit 2010 79-10.pdf PDF
Permit 206-10.pdf PDF
36C25025Q0410 0001.docx DOCX document
36C25025Q0410.docx DOCX document
P07 WD No. 2015-4865 Rev. 26.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Facility Fuel Combustion GHG Worksheet
Use this worksheet to collect basic information about the fuel combustion devices/ equipment that generate GHGs at your facility. This information will be useful to calculate the potential to emit (PTE) of Carbon Dioxide equivalent for each device then totaled at the bottom for a facility-wide PTE.
1) Device Type (boiler, generator, oven, dryer, water heater (WH), space heater, emergency generator, engines/ compressors, other fuel combustion devices such as heat treatment equipment2) Identifier (example, SN (S), Model # (M), EE#)3) Fuel combusted (natural gas, propane, fuel oil)4) Max Design Capacity (MMBtu/ hr, Btu/Hr, kW) found on nameplate of the unit5) Identified in an Air Permit? (No, Yes (enter permit number and limit)
Emergency Generator 1, Build. 19S: B010204440Diesel400 kWNo/Exempt
Emergency Generator 2, Build. 19S: 331914-1-1-0411Diesel400 kWNo/Exempt
Emergency Generator 3, Build. 19S: G920477586Diesel350 kWNo/Exempt
Emergency Generator E/CS: 320019-1-1-0410Diesel750 kW79-10
Emergency Generator Build. 6 (REMOVED)M: U6409448Diesel100 kWNo/Exempt
Emergency Generator Build. 21M:16601001486Diesel500 kWMDD-STNRCI-09-01
Emergency Generator Building 3M:GGHG-7090865
S: D08177283Nat. Gas85 kWNo/Exempt
Boiler 1 Building 6 (REMOVED)M: CR200X250Nat. Gas10,461,000 Btu/hrNo/Exempt
Boiler 2 Building 6 (REMOVED)M: CR200X250Nat. Gas10,461,000 Btu/hrNo/Exempt
Boiler 3 Building 6 (REMOVED)M: 829401Nat. Gas6,276,600 Btu/hrNo/Exempt
water heater Building 6M: MI40T6FBNGAS40,000 Btu/hrNo/Exempt
Domestic WH 1 E/CS: G-10-0815GAS902,100 Btu/hrNo/Exempt
Domestic WH 2 E/CS: G-10-0817GAS902,100 Btu/hrNo/Exempt
Domestic WH 3 E/CS: G-10-0816GAS902,100 Btu/hrNo/Exempt
Boiler 1 E/CM: ZFC1100WNat. Gas10,353 MBtu/hr79-10
Boiler 2 E/CM: ZFC1100WNat. Gas10,353 MBtu/hr79-10
Boiler 3 E/CM: ZFC1100WNat. Gas10,353 MBtu/hr79-10
Water Heater Building 3M: PRN050G S:HH15479464GAS60,000 Btu/hrNo/Exempt
Boiler 1 Building 3M: KBN800 S:KO9H10123618GAS746,400 Btu/hr79-10
Boiler 2 Building 3M: KBN800 S:KO9H10123082GAS746,400 Btu/hr79-10
Boiler 3 Building 3M: KBN800 S:KO9H10123625GAS746,400 Btu/hr79-10
Boiler 1 Building 9M: KBN600 S:KO9H10120172GAS559,000 Btu/hr79-10
Boiler 2 Building 9M: KBN600 S:KO9H10122548GAS559,000 Btu/hr79-10
Boiler 3 Building 9M: KBN600 S:KO9H10122554GAS559,000 Btu/hr79-10
Chapel roof preheaterM: PVF250H S:12285845GAS200,000 Btu/hrNo/Exempt