Orange_County_Standards_and_Guidelines_Access_Control.pdf

PDF 366 KB Posted

Attached to
Corrections FDC BAS Replacement and Fire Alarm Upgrade
Solicitation number
Y26-717
Issued by
Orange County, Orlando City, Florida

View the file

Other files

File Type Posted
Corrections_FDC_BAS_Replacement_and_Fire_Alarm_Upgrade_(Addendum_#6_Revision).pdf PDF
Corrections_FDC_BAS_Replacement_and_Fire_Alarm_Upgrade_(Addendum_#6_Revision).pdf PDF
Corrections_FDC_BAS_Replacement_and_Fire_Alarm_Upgrade_(Addendum_#5_Revision).pdf PDF
Corrections_FDC_BAS_Replacement_and_Fire_Alarm_Upgrade_(Addendum_#4_Revision).pdf PDF
Corrections_FDC_BAS_Replacement_and_Fire_Alarm_Upgrade_(Addendum_#3_Revision).pdf PDF
Corrections_FDC_BAS_Replacement_and_Fire_Alarm_Upgrade.pdf PDF
Orange_County_ISS_Infrastructure_Standards_and_Specifications.pdf PDF
Y26-717_Specifications.pdf PDF
Orange_County_Standards_and_Guidelines_Access_Control.pdf PDF
Orange_County_ISS_Infrastructure_Standards_and_Specifications.pdf PDF
Orange_County_ISS_Infrastructure_Standards_and_Specifications.pdf PDF
Orange_County_Standards_and_Guidelines_Access_Control.pdf PDF
Orange_County_ISS_Infrastructure_Standards_and_Specifications.pdf PDF
Orange_County_ISS_Infrastructure_Standards_and_Specifications.pdf PDF
Orange_County_Standards_and_Guidelines_Access_Control.pdf PDF
Y26-717_Specifications.pdf PDF
Y26-717_Specifications.pdf PDF
Orange_County_ISS_Infrastructure_Standards_and_Specifications.pdf PDF
Y26-717_Specifications.pdf PDF
Y26-717_Specifications.pdf PDF
Orange_County_Standards_and_Guidelines_Access_Control.pdf PDF
Y26-717_Specifications.pdf PDF
Orange_County_Standards_and_Guidelines_Access_Control.pdf PDF
Y26-717_Drawings.pdf PDF
Y26-717_Drawings.pdf PDF
Y26-717_Drawings.pdf PDF
Y26-717_Drawings.pdf PDF
Y26-717_Drawings.pdf PDF
Y26-717_Drawings.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Enterprise Security – Electronic Security

Standards and Guidelines for Access Control

Purpose:

The purpose of this document is to establish policies and standards to protect physical access to secured locations and facilities for Orange County Government Board of County Commissioners

(OCGBCC) through Door Access Control systems across the OCGBCC Enterprise.

Scope:

The standards in this document apply to all Physical Security Systems located within OCGBCC information systems and networks. The Information Systems and Services, Enterprise Security

Department, is responsible to oversee all aspects of Electronic Security Control across the

OCGBCC Enterprise. These systems are 24x7x365 production environments which are designed to increase safety, efficiency and limit liability to OCGBCC and its citizens.

Definition:

“Door Access Control” refers to access control using badges and/or PIN numbers and/or biometrics to access doors throughout Orange County.

Policy:

Any new access control platforms solicited for new buildings or replacement for existing buildings shall adhere to these standards. Any and all Access Control installations, removals or modifications shall require the direct involvement of the Electronic Security Unit and documented approval by the Orange County Security Committee.

Standards:

There is one standard Door Access Control system used by OCGBCC Lenel OnGuard. This system integrates disparate hardware and software components providing reliable management interfaces across the enterprise network.

For all new implementations or modifications, all hardware components shall be compliant with the Mercury Open Architecture.

The different hardware components that work directly and/or integrate with Lenel are:

• Intelligent System Controller

LNL-X2210

LNL-X2220

LNL-X3300

LNL-X4420

• Reader Interface module

LNL-1300-S3

LNL-1320-S3

• Input and output control modules

LNL-1100-S3

LNL-1200-S3

• Multi-technology Readers- Allegion

Allegion MT11-485

Allegion MT15-485

Allegion MTK15-485

• Electric door strike – Check with OC Facilities Locksmith for part number

• Electric Panic Devices - Check with OC Facilities Locksmith for part number

• Electric Lockset - Check with OC Facilities Locksmith for part number

• Door position switch – GR194-12WG-B GR4400-A

• Motion sensor – Bosch DS160

• Request to exit button - Alarm Control TS2 – TS12

• ADA compatible crash bar Von-Duprin - Check with OC Facilities Locksmith for part number

• Panic button – wired GR3045

• Biometric reader

• Inovonics Wireless Receivers – EN4204MR – EN4216MR – EN4232MR

• Inovonics Wireless Transmitters – EN1233S – EN1235S

• Life Safety Power Supply and Enclosure – FPO150/250-2D8P2M8NL4E6M1

• Gate Access Control

Box at Gates for Access Interfaces to Gate Controller and Building

• Each of the Pedestal Locations ( Card Reader would need a Concrete Pad to allow the Pedestal to be mounted. Pedestal base is 8” x 8” so Concrete should be at least 12” x 12” with the appropriate depth. Also, each pedestal would need ¾” conduit pathway back to Exterior Enclosure

• CSD36248 - ENCLOSURE ( Hoffman / NVENT )

• CP3624 - PANEL ( Hoffman / NVENT )

• CWHK - LOCKING HANDLE ( Hoffman / NVENT )

• AFK1808 for Floor Stand Kit mounted to Concrete Base ( Hoffman / NVENT )

• Or CMFK for Mounting Bracket Ears used with Unistrut Structure

• If Stainless Steel Boxes are required for the location then change the CSD36248 to

CSD36248SS

• 12 Strands of SM Fiber with LC terminations at the Enclosure o Fiber would need to Terminate in a Rack Mounted LIU with LC Terminations in the building o Fiber would typically terminate in a Wall Mounted LIU approx. 6 inches x 4 inches in the Enclosure with LC Patch Panel

• Each Enclosure would require a Quad 110vac Outlet in the lower corner and a Ground Bar

• All conduits carrying the fiber would need to have large sweeps to avoid fiber taking abrupt turns through the conduit pathways

• If Elbows are utilized, they would need to be larger to allow fiber to route through without abrupt changes in direction

• Surge Protection DTK-4LVLPCR - DTK-2LVLPX

• Gate Pedestal – Pedestal Pro

• Gate Pedestal Housing – Pedestal Pro

• Fiber Media Converter - Comnet

Integrator is responsible to program any new or add on device in the Lenel System.

List of Lenel Preferer Integrators use by OC

Security 101

Convergint Technologies

The Intercom System Standard for OC is Zenitel (Stentofon)

County Wide Edge System

• Video Door Station – TCIV-2+ - TCIV-3+ - TCIV-5+ - TCIV-6+ - TEN-4+ - TMIV-1+ - ZSD-1

• Master Station - ITSV-4 – ITSV-5

Corrections Alphacom System

INFORMATION SYSTEMS AND SERVICES DIVISION

COUNTY ADMINISTRATION

400 E. South Street, 4th Floor, Orlando, Florida 32801

Telephone (407) 836-5200 FAX (407) 836-5299 http://www.orangecountyfl.net

INFORMATION SYSTEMS AND SERVICES DIVISION
COUNTY ADMINISTRATION
400 E. South Street, 4th Floor, Orlando, Florida 32801
Telephone (407) 836-5200 ( FAX (407) 836-5299 ( http://www.orangecountyfl.net

File details come from the government source that posted it. Updated .