This is a construction bid set document prepared for the City of DeBary, Florida for Phase 1 of the Alexander Island Park project, specifically addressing the Operations Building fencing and landscape improvements. The project is located at Alexander Island Park in DeBary, Florida (Section 8, Township 19, Range 30) and includes comprehensive landscape, hardscape, and structural work. The scope encompasses the installation of plant materials from the detailed plant schedule (including canopy trees, palms, shrubs, and ground covers totaling thousands of individual plants), approximately 43,437 square feet of Argentine Bahia grass sod, 630 linear feet of split rail decorative fencing, 57 linear feet of PVC screening fence, 42 linear feet of cable railing, multiple gates, hardscape elements including 1,857 square feet of concrete pavement, site furnishings (benches, picnic tables, bike racks, trash receptacles), decorative accent columns, trail kiosks, and three buildings (restroom, operations, and storage garage). The construction plans include detailed landscape and irrigation specifications, hardscape plans, structural notes, electrical diagrams, stormwater details, and utility coordination requirements with Florida Power & Light and Volusia County Water & Utility.
The project requires contractors to maintain all plant materials and lawns for a minimum one-year warranty period commencing at certification of acceptance by the owner's representative. All landscaping materials must meet Florida Grade #1 or better quality standards, with plant materials subject to approval before, during, and after installation. The contractor is responsible for locating all utilities 48 hours before construction begins by contacting Sunshine State One Call of Florida (811) and must protect all existing utilities and structures. Soil mixture specifications require two parts topsoil to one part sand with pH between 5.5 and 7.0, and all planting areas must receive minimum 4 inches of topsoil with 3-inch depth of designer brown hardwood mulch. The contractor assumes full responsibility for delivery schedules, plant health maintenance during delivery and installation, proper watering and irrigation coordination, and replacement of any diseased or dead plant material at the contractor's cost. Damaged existing trees are subject to liquidated damages of $300 per caliper inch with 20 percent escalation for trees exceeding 4 inches in caliper. The project involves coordination with multiple professional teams including Kimley-Horn and Associates (civil engineer, structural engineer, geotechnical engineer), Terracon (landscape architect), Cabral Engineering (electrical engineer), and Breedlove, Dennis & Associates (environmental consultant).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP_3226Exhibit_I__Bid_Price_Sheet.xlsx | XLSX spreadsheet | |
| Phase_1_General_Plans_A_Updated_81826.pdf | ||
| RFP_3226__Alexander_Island_ParkPhase_1Uplands.pdf | ||
| L3.02_HARDSCAPE_PLAN.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AUGUST 18, 2026
DEBARY, FLORIDA
AERIAL MAP
ALEXANDER ISLAND PARK - OPS
BUILDING FENCING & LANDSCAPE
ISSUED FOR CONSTRUCTION PLANS
FOR
PROJECT TEAM
PROJECT LOCATION
PREPARED BY
SECTION 8, TOWNSHIP 19, RANGE 30
CIVIL ENGINEER:
CITY OF DEBARY
16 COLOMBA ROAD
DEBARY, FL 32713
CONTACT: CARMEN ROSAMONDA
PHONE: (386) 668-2040
EMAIL: CROSAMONDA@DEBARY.ORG
OWNER/DEVELOPER:
KIMLEY-HORN AND ASSOCIATES, INC.
200 S. ORANGE AVENUE, SUITE 600
ORLANDO, FL 32801
CONTACT: BRENT A. LENZEN, P.E.
PHONE: (407) 898-1511
EMAIL: BRENT.LENZEN@KIMLEY-HORN.COM
SURVEYOR
ALLEN & COMPANY
16 EAST PLANT STREET
WINTER GARDEN, FLORIDA 34787
PHONE:(407) 654-5355
VICINITY MAP
PROJECT LOCATION
N O
R
TH
N O
R
TH
UTILITY PROVIDERS
POWER:
FLORIDA POWER & LIGHT
2626 W. 1ST STREET
SANFORD, FL 32771
CONTACT: JOSH FURUKAWA
PHONE: (407) 328-1911
EMAIL: JOSHUA.FURUKAWA@FLP.COM
VOLUSIA COUNTY WATER & UTILITY
3151 E. NEW YORK
DELAND, FL 32720
CONTACT: DR. ERIN REED, P.E.
PHONE: (386) 943.7027 EXT. 13287
EMAIL: ERINREED@VOLUSIA.ORG
WATER, SEWER,
& RECLAIM WATER:
CALL 48 HOURS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
Know what's below.
Call before you dig. PROFES S I O NA L ENG I N
EE
R«
BRENT A. LENZEN
No. 78537
STATE OF
FL O R I DA
LICENSE
PROJECT LOCATION
NOT TO SCALENOT TO SCALE
FORT FLORIDA ROAD
LANDSCAPE ARCHITECT:
TERRACON
1675 LEE ROAD
WINTER PARK, FL 32789
CONTACT: SHENNA MCMASTER
PHONE: (407) 618-8362
EMAIL: SHENNA.MCMASTER@TERRACON.COM
GEOTECHNICAL ENGINEER:
KIMLEY-HORN AND ASSOCIATES, INC.
200 S. ORANGE AVENUE, SUITE 600
ORLANDO, FL 32801
CONTACT: SCOTT MINGONET, P.L.A.
PHONE: (407) 898-1511
EMAIL: SCOTT.MINGONET@KIMLEY-HORN.COM
ELECTRICAL ENGINEER:
CABRAL ENGINEERING, INC.
618 E SOUTH STREET,
ORLANDO, FL 32801
CONTACT: FRANCISCO CABRAL
PHONE: 321-246-4041
EMAIL: FRANCISCO@CABRALENGINEERING.COM
ENVIRONMENTAL:
BREEDLOVE, DENNIS & ASSOCIATES, INC.
30 EAST LIBERTY STREET
BROOKSVILLE, FL 34601
CONTACT: JENNIFER ROSINSKI
PHONE: (352) 799-9488
TABLE OF CONTENTS
SHEET NUMBER SHEET NAME REV. 1 REV. 2 REV. 7
L1.00 OVERALL LANDSCAPE PLAN
L1.01 - L1.02 LANDSCAPE PLAN
L1.50 LANDSCAPE DETAILS
L1.51 LANDSCAPE AND IRRIGATION
SPECIFICATIONS
L3.00 OVERALL HARDSCAPE PLAN
L3.01 - L3.03 HARDSCAPE PLAN
L3.08 HARDSCAPE MATERIAL SCHEDULE
IFC
L0.50 OVERALL TREE MITIGATION PLAN
L0.51 TREE MITIGATION SPECIFICATIONS &
DETAIL
- INCLUDED IN THIS SET
- NOT INCLUDED IN THIS SET
STRUCTURAL ENGINEER:
KIMLEY-HORN AND ASSOCIATES, INC.
1920 WEKIVA WAY, SUITE 200
WEST PALM BEACH , FL 33411
CONTACT: J. CASEY LONG
PHONE: 561-840-0838
EMAIL: CASEY.LONG@KIMLEY-HORN.COM
L3.51 - L3.55 HARDSCAPE DETAILS
C2.0 STORMWATER POLLUTION PREVENTION
PLAN
C3.0 EXISTING CONDITIONS AND DEMOLITION
PLAN
C4.0 SITE PLAN
C5.0 PAVING, GRADING, AND DRAINAGE PLAN
C6.0 UTILITY PLAN
C0.0 COVER SHEET
C1.0 - C1.1 GENERAL NOTES
C7.0 - C7.2 CONSTRUCTION DETAILS
C8.0 - C8.3 VOLUSIA COUNTY UTILITIES DETAILS
E001 ELECTRICAL SPECIFICATIONS AND
GENERAL NOTES
E101 SITE ELECTRICAL PLAN
E201 SITE PHOTOMETRICS
E801 ELECTRICAL DIAGRAMS SCHEDULES AND
DETAILS
C7.3 LIFT STATION DETAILS
C5.1 CROSS SECTIONS
L3.60 STRUCTURAL NOTES
E802 ELECTRICAL DIAGRAMS SCHEDULES AND
DETAILS
COMMUNICATIONS
AT&T
2783 ELKCAM BLVD, SUITE 101
DELTONA, FL 32763
PHONE: 386-281-6122
3 4 5 6
S0.01-S3.00 STRUCTURAL NOTES AND PLANS
rvillasenor Line rvillasenor Line
29 LF OF 24" HP STORM PP @ 1.75%
37 LF OF 30" HP STORM PP @
1.36%
LF
O F
" H
P S
TO
RM P
P @
9.
LF
O
F
" R C
P
.8
3%
LF
O F 12
" H
P STORM PP @
0.
7 L F O
F 12 " H
P STORM PP @
0.
1 LF OF 12" HP STORM PP @ 0.00%
45 LF OF 8" PVC @ 0.00%
48 LF OF 8" PVC @
0.00%
L
F O
F 8"
P
VC
.0 0%
42 LF OF 8" PERFORRATED PIPE @ 0.00%
LF
O
F 8"
P
ER
FO
R
R
AT
ED
P
IP
E
.0 0%
LF
O
F 8"
P
VC
.0 0%
83 LF OF 8" PVC @
0.00%
L
F O
F 8"
P
ER
FO
R
R
AT
ED
P
IP
E
.0 0%
LF
O
F 8"
P
ER
FO
R
R
AT
ED
P
IP
E
.0 0%
64 LF OF 8" PVC @ 0.00%
42 LF OF 8" PERFORRATED PIPE @ 0.00%
L F
O F
8" P
VC
.4
6%
42 LF OF 12" HP STORM PP @ 0.00%
L
F O
F 8"
P
VC
.4 6%
LF
O
F 8"
P
ER
FO
R
R
AT
ED
P
IP
E
.0 0%
42 LF OF 12" HP STORM PP @ 0.00%
63 LF OF 8" PVC @ 0.00%
34 LF OF 12" HP STORM PP @ 0.00%
W
W W
W
W
W
W
W W
W
W
W
WWW
W W
W W
W W
W
W
W
W
W
W W W
W
RW RW
RW
R W
RW
R W
R W
RW
RW
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM FM
FM
FM
FM
FM
FM
FM
FM
FM
T
T
T
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT CAL SIZE REMARKS
CANOPY TREE
AF 7 FLORIDA FLAME RED MAPLE ACER RUBRUM 'FLORIDA FLAME' FG 3" CAL. 14` HT., 5` SPR. STRAIGHT, SINGLE LEADER, FULL, FL #1
PO 3 AMERICAN SYCAMORE PLATANUS OCCIDENTALIS F.G. 3" CAL. 14` HT., 6` SPR. STRAIGHT, SINGLE LEADER, FULL, FL #1
QV 10 SOUTHERN LIVE OAK QUERCUS VIRGINIANA FG 3" CAL. 14` HT., 6` SPR. STRAIGHT, SINGLE LEADER, FULL, FL #1
QV2 4 SOUTHERN LIVE OAK QUERCUS VIRGINIANA FG 7" CAL MIN 20` HT STRAIGHT, SINGLE LEADER, FULL, FL #1, 5' CT., SPECIMEN QUALITY
TD1 8 BALD CYPRESS TAXODIUM DISTICHUM FG 3" CAL MIN 12` HT., 5` SPR. SINGLE, STRAIGHT, FL #1, FULL
PALM TREES
SP1 7 SABAL PALM SABAL PALMETTO FG 10` CT STRAIGHT, SINGLE LEADER, FL #1, FULL, FULLY
REGENERATED
SP2 7 SABAL PALM SABAL PALMETTO FG 14` CT STRAIGHT, SINGLE LEADER, FL #1, FULL, FULLY
REGENERATED
SP3 7 SABAL PALM SABAL PALMETTO FG 18` CT STRAIGHT, SINGLE LEADER, FL #1, FULL, FULLY
REGENERATED
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE SPACING REMARKS
SHRUBS
CBB 25 AMERICAN BEAUTYBERRY CALLICARPA AMERICANA 7 GAL 18" FULL SEE PLAN FULL
IP 103 FLORIDA ANISE ILLICIUM FLORIDANUM 3 GAL 36" FULL 36" OC FULL
MCW 7 WAX MYRTLE MYRICA CERIFERA 30 GAL 60" HT SEE PLAN FULL TO GROUND
SR 122 SAW PALMETTO SERENOA REPENS 3 GAL 30" FULL 36" OC FULL, SPECIMEN QUALITY
TD 80 FAKAHATCHEE GRASS TRIPSACUM DACTYLOIDES 3 GAL 30" FULL 48" OC FULL
TDN 253 DWARF FAKAHATCHEE GRASS TRIPSACUM DACTYLOIDES NANA 3 GAL 18" FULL 36" OC FULL
VO 114 SWEET VIBURNUM VIBURNUM ODORATISSIMUM 7 GAL 30" HT 30" OC FULL
ZF 37 CARDBOARD PALM ZAMIA FURFURACEA 7 GAL 30" HT 48" OC FULL
SHRUB AREAS
DI 338 AFRICAN IRIS DIETES IRIDIOIDES 3 GAL 24" FULL 24" OC FULL, SYMMETRIAL APPEARANCE
DTB 139 VARIEGATED BLUEBERRY FLAX LILY DIANELLA TASMANICA `BLUEBERRY` 3 GAL 12" FULL 24" OC FULL, VARIEGATED
MC 399 PINK MUHLY GRASS MUHLENBERGIA CAPILLARIS 3 GAL 24" FULL 30" OC FULL
VOS 477 MISS SCHILLERS DELIGHT VIBURNUM VIBURNUM OBOVATUM 'MISS SCHILLERS DELIGHT' 3 GAL 24" FULL 30" OC FULL
ZP 281 COONTIE CYCAD ZAMIA PUMILA 7 GAL 30" FULL 30" OC FULL
GROUND COVERS
LE 778 EMERALD GODDESS LILYTURF LIRIOPE MUSCARI 'EMERALD GODDESS' 1 GAL 12" SPRD MIN 18" OC FULL
LM2 144 TRAILING PURPLE LANTANA LANTANA MONTEVIDENSIS 'TRAILING PURPLE' 1 GAL 12" SPRD MIN 18" OC FULL
SOD
PA 43,437 SF ARGENTINE BAHIA GRASS PASPALUM NOTATUM 'ARGENTINE' SOD - - ROLLED TIGHT, 100%
WEED/INSECT/DIESEASE/DEBRIS FREE
PLANT SCHEDULE
1 2 7
AL
EX
AN
D
ER
IS
LA
N D
PA
R
K
- P
H
AS
E
PR
EP
AR
ED
F O
R
C
IT
Y O
F D
EB
AR
Y
O
VE
R
AL
L
LA
N D
SC
AP
E
PL
AN
L1.00
Know what'sbelow.
Callbefore you dig.
CALL 2 WORKING DAYS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
NORTH
L1.01 L1.02
LANDSCAPE NOTES:
1. ALL LANDSCAPE MATERIAL TO BE FLORIDA GRADE #1 OR BETTER QUALITY
2. ALL LANDSCAPED AREAS ARE TO RECEIVE A MINIMUM OF 4" OF TOPSOIL.
3. ALL PLANT MATERIAL SHALL BE HEALTHY, VIGOROUS, AND FREE OF PESTS AND DISEASE.
4. ALL MATERIALS ARE SUBJECT TO THE APPROVAL OF THE LANDSCAPE ARCHITECT BEFORE, DURING, AND AFTER INSTALLATION.
5. ALL TREES MUST BE GUYED OR STAKED AS SHOWN IN THE DETAILS.
6. ALL PLANTING AREAS SHALL BE COMPLETELY MULCHED AS SPECIFIED.
7. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL AVOID DAMAGE TO ALL UTILITIES DURING THE COURSE OF THE WORK. LOCATIONS OF EXISTING BURIED UTILITY LINES SHOWN ON THE PLANS ARE BASED UPON BEST AVAILABLE INFORMATION AND ARE TO BE CONSIDERED APPROXIMATE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 1) TO VERIFY THE LOCATIONS OF UTILITY LINES ADJACENT TO THE WORK AREA 2) TO PROTECT ALL UTILITY LINES DURING THE CONSTRUCTION PERIOD 3) TO REPAIR ANY AND ALL DAMAGE TO UTILITIES, STRUCTURES, SITE APPURTENANCES, ETC. WHICH OCCURS AS A RESULT OF THE CONSTRUCTION.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL QUANTITIES SHOWN ON THESE PLANS BEFORE PRICING THE WORK.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY SCHEDULE AND PROTECTION BETWEEN DELIVERY AND PLANTING TO MAINTAIN HEALTHY PLANT CONDITIONS.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FULLY MAINTAINING (INCLUDING BUT NOT LIMITED TO: WATERING, SPRAYING, MULCHING, FERTILIZING, ETC.) ALL OF THE PLANT MATERIALS
AND LAWN FOR THE WARRANTY PERIOD.
11. ANY PLANT MATERIAL WHICH IS DISEASED, DISTRESSED, DEAD, OR REJECTED (PRIOR TO SUBSTANTIAL COMPLETION) SHALL BE PROMPTLY REMOVED FROM THE SITE AND REPLACED WITH MATERIAL OF THE SAME SPECIES, QUANTITY, AND SIZE AND MEETING ALL PLANT LIST SPECIFICATIONS.
12. THE CONTRACTOR SHALL COMPLETELY GUARANTEE ALL PLANT MATERIAL FOR WARRANTY PERIOD. THE CONTRACTOR SHALL PROMPTLY MAKE ALL REPLACEMENTS DURING THE NORMAL
PLANTING SEASON.
13. STANDARDS SET FORTH IN "AMERICAN STANDARD FOR NURSERY STOCK" REPRESENT GUIDELINE SPECIFICATIONS ONLY AND SHALL CONSTITUTE MINIMUM QUALITY REQUIREMENTS FOR
PLANT MATERIAL.
14. ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND NURSERY PRACTICES, AND SHALL BE FLORIDA NO. 1 OR BETTER AS GIVEN IN "GRADES AND STANDARDS FOR NURSERY
PLANTS, PARTS I AND II," STATE OF FLORIDA, DEPARTMENT OF AGRICULTURE.
15. ALL INVASIVE / EXOTIC SPECIES AND PROHIBITED TREE SPECIES SHALL BE REMOVED FROM SITE, INCLUDING ROOT BALLS TO THE EXTENT POSSIBLE WITH NO DAMAGE TO ADJACENT
EXISTING TREES.
16. TREE SUPPORT MATERIALS ARE TO BE REMOVED FROM EACH TREE ONCE IT IS "ESTABLISHED" (AS APPROVED BY THE LANDSCAPE ARCHITECT).
17. ALL PLANT SPECIFICATIONS IN THE PLANT SCHEDULE SHALL BE CONSIDERED THE MINIMUM ALLOWABLE SPECIFICATIONS. CONTRACTOR SHALL PROCURE PLANT MATERIALS AND UPSIZE AS
NECESSARY TO MEET THE MOST STRINGENT SPECIFICATION.
18. ALL PLANTED LANDSCAPE AREAS TO HAVE 3" DEEP DESIGNER BROWN HARDWOOD MULCH & AMENDED SOILS.
REPAIR AS NEEDED DURING CONSTRUCTION. SUBMIT ALTERNATIVE MULCH SPECIFICATION FOR LANDSCAPE
ARCHITECT APPROVAL.
MISC. QTY BOTANICAL/COMMON NAME SPECIFICATIONS
MULCH TBD DESIGNER BROWN HARDWOOD MULCH 3" DEPTH MINIMUM, SHREDDED, FREE OF WEEDS/INVASIVE PLANT MATERIAL
PRESERVED
LANDSCAPE AREA
PROPERTY LINE
EDGE OF
WATER
FORT FLORIDA ROAD
PRESERVED
LANDSCAPE AREA
EDGE OF WATER
REST.
STORMWATER
POND
ST
. J
O H
N S
R
IV
ER
FO
R
T FLO
R
ID
A R
O
AD
PRESERVED
LANDSCAPE
AREA
PRESERVED
LANDSCAPE AREA
EDGE OF WETLAND, TYP.
WETLAND
LINE, TYP.
WETLAND LINE,
TYP.
STORMWATER
POND
ST
. J
O H
N S
R
IV
ER
STORAGE
GARAGE
OP
BUILDING
WETLAND LINE, TYP
WETLAND LINE
25' WETLAND BUFFER LINE /
25' AVG. 15' MIN., TYP.
WETLAND LINE, TYP.
OVERHEAD POWER
LINES, TYP.
EXISTING TREE, TYP.
EXISTING FLOODPLAIN LINE, TYP.
25' WETLAND BUFFER LINE /
25' AVG. 15' MIN., TYP.
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT CAL SIZE REMARKS
CANOPY TREE
AF 7 FLORIDA FLAME RED MAPLE ACER RUBRUM 'FLORIDA FLAME' FG 3" CAL. 14` HT., 5` SPR. STRAIGHT, SINGLE LEADER, FULL, FL #1
PO 3 AMERICAN SYCAMORE PLATANUS OCCIDENTALIS F.G. 3" CAL. 14` HT., 6` SPR. STRAIGHT, SINGLE LEADER, FULL, FL #1
QV 10 SOUTHERN LIVE OAK QUERCUS VIRGINIANA FG 3" CAL. 14` HT., 6` SPR. STRAIGHT, SINGLE LEADER, FULL, FL #1
QV2 4 SOUTHERN LIVE OAK QUERCUS VIRGINIANA FG 7" CAL MIN 20` HT STRAIGHT, SINGLE LEADER, FULL, FL #1, 5' CT., SPECIMEN QUALITY
TD1 8 BALD CYPRESS TAXODIUM DISTICHUM FG 3" CAL MIN 12` HT., 5` SPR. SINGLE, STRAIGHT, FL #1, FULL
PALM TREES
SP1 7 SABAL PALM SABAL PALMETTO FG 10` CT STRAIGHT, SINGLE LEADER, FL #1, FULL, FULLY
REGENERATED
SP2 7 SABAL PALM SABAL PALMETTO FG 14` CT STRAIGHT, SINGLE LEADER, FL #1, FULL, FULLY
REGENERATED
SP3 7 SABAL PALM SABAL PALMETTO FG 18` CT STRAIGHT, SINGLE LEADER, FL #1, FULL, FULLY
REGENERATED
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE SPACING REMARKS
SHRUBS
CBB 25 AMERICAN BEAUTYBERRY CALLICARPA AMERICANA 7 GAL 18" FULL SEE PLAN FULL
IP 103 FLORIDA ANISE ILLICIUM FLORIDANUM 3 GAL 36" FULL 36" OC FULL
MCW 7 WAX MYRTLE MYRICA CERIFERA 30 GAL 60" HT SEE PLAN FULL TO GROUND
SR 122 SAW PALMETTO SERENOA REPENS 3 GAL 30" FULL 36" OC FULL, SPECIMEN QUALITY
TD 80 FAKAHATCHEE GRASS TRIPSACUM DACTYLOIDES 3 GAL 30" FULL 48" OC FULL
TDN 253 DWARF FAKAHATCHEE GRASS TRIPSACUM DACTYLOIDES NANA 3 GAL 18" FULL 36" OC FULL
PLANT SCHEDULE
29 LF OF 24" HP STORM PP @ 1.75%
45 LF OF 8" PVC @ 0.00%
48 LF OF 8" PVC @
0.00%
L
F O
F 8"
P
VC
.0 0%
42 LF OF 8" PERFORRATED PIPE @ 0.00%
LF
O
F 8"
P
ER
FO
R
R
AT
ED
P
IP
E
.0 0%
LF
O
F 8"
P
VC
.0 0%
L
F O
F 8"
P
ER
FO
R
R
AT
ED
P
IP
E
.0 0%
LF
O
F 8"
P
ER
FO
R
R
AT
ED
P
IP
E
.0 0%
64 LF OF 8" PVC @ 0.00%
42 LF OF 8" PERFORRATED PIPE @ 0.00%
L
F O
F 8"
P
VC
.4 6%
W
W W
W W
W
W W W
W
W
W
W
W
W
W
W
W W W W W
W
W
W W
W W
W W
W W
W
W W W
W
W
W
W
W
W
W
W
W W W W W
W W
W
W
RW
RW
RW
RW
RW
RW
RW RW
R W
R W
R W
R W
RW
RW
RW
RW
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM FM FM FM FM
FM
FM
FM FM
RW
FM
FM
FM
FM
FM
FM
FM
FM
FM
T
DI
ZP
TDN
TD
SR
SP1
TDN
13SP3
IP
DI
ZP
DTB
DI
TDN
DI
ZP
DI
ZP
TD
IP
SP2
SP3
SR
SP1
QV2
TD
DTB
QV2
AF
TDN
TDN
DTB
ZF
DI
SP2
SR
SP3
SP1
TD
QV2
IP
SP2ZP
SP3
SR
SP1
ZP
DI
SR
TDN
ZP
CBB
SR
DI
ZP
ZP
PA
3,336 sf
QV2
TDN8
VO
DI
MC
SP2
SP3
TDN
MC
SP1
10,908 sf
PA
QV
VOS
LE
LE
VOS
QV
LM2
DTB
TDN
LM2
CBB
ZP
LM2
VOS
LE
MC
LE
VOS
3,344 sf
PA
LM2
VOS
PO
4,619 sf
PA
VOS
VOS
LE
QV
TDN
TDN
SR
SR
SP2
ZP
DI
DTB
MC
MC
LE
DTB
LE
VOS
LE
VOS
SP1
SP2
SP3
PO
TD
AF
MC
TD
ZF
QV
LE
QV
ZP
TD1
TD1
ZP
VO 114 SWEET VIBURNUM VIBURNUM ODORATISSIMUM 7 GAL 30" HT 30" OC FULL
ZF 37 CARDBOARD PALM ZAMIA FURFURACEA 7 GAL 30" HT 48" OC FULL
SHRUB AREAS
DI 338 AFRICAN IRIS DIETES IRIDIOIDES 3 GAL 24" FULL 24" OC FULL, SYMMETRIAL APPEARANCE
DTB 139 VARIEGATED BLUEBERRY FLAX LILY DIANELLA TASMANICA `BLUEBERRY` 3 GAL 12" FULL 24" OC FULL, VARIEGATED
MC 399 PINK MUHLY GRASS MUHLENBERGIA CAPILLARIS 3 GAL 24" FULL 30" OC FULL
VOS 477 MISS SCHILLERS DELIGHT VIBURNUM VIBURNUM OBOVATUM 'MISS SCHILLERS DELIGHT' 3 GAL 24" FULL 30" OC FULL
ZP 281 COONTIE CYCAD ZAMIA PUMILA 7 GAL 30" FULL 30" OC FULL
GROUND COVERS
LE 778 EMERALD GODDESS LILYTURF LIRIOPE MUSCARI 'EMERALD GODDESS' 1 GAL 12" SPRD MIN 18" OC FULL
LM2 144 TRAILING PURPLE LANTANA LANTANA MONTEVIDENSIS 'TRAILING PURPLE' 1 GAL 12" SPRD MIN 18" OC FULL
SOD
PA 43,437 SF ARGENTINE BAHIA GRASS PASPALUM NOTATUM 'ARGENTINE' SOD - - ROLLED TIGHT, 100%
WEED/INSECT/DIESEASE/DEBRIS FREE
1 2 7
AL
EX
AN
D
ER
IS
LA
N D
PA
R
K
- P
H
AS
E
PR
EP
AR
ED
F O
R
C
IT
Y O
F D
EB
AR
Y
LA
N D
SC
AP
E
PL
AN
L1.01
Know what'sbelow.
Callbefore you dig.
CALL 2 WORKING DAYS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
NORTH
MATCHLINE; SEE SHEET L1.02
MISC. QTY BOTANICAL/COMMON NAME SPECIFICATIONS
MULCH TBD DESIGNER BROWN HARDWOOD MULCH 3" DEPTH MINIMUM, SHREDDED, FREE OF WEEDS/INVASIVE PLANT MATERIAL
LANDSCAPE NOTES:
- BAHIA SOD TO BE APPLIED TO ALL DISTURBED AREAS
SOD
SOD
SOD
MULCH
SOD
SOD
SOD
MAINTAIN EXISTING
VEGETATION
BENEATH EXISTING
TREES, TYP.
SOD
SOD
MAINTAIN EXISTING
VEGETATION
BENEATH EXISTING
TREES
MAINTAIN EXISTING
VEGETATION
BENEATH EXISTING
TREES, TYP.
PRESERVED
LANDSCAPE
AREA
PRESERVED
LANDSCAPE
AREA
STORMWATER
SWALE
RIGHT OF
WAY
RIGHT-OF-WAY, TYP.
OVERHEAD
POWERLINES
EDGE OF
WETLAND,
TYP.
EDGE OF WETLAND, TYP.
EDGE OF WETLAND, TYP.
EXISTING TREE, SEE
TREE MITIGATION
PLANS (TYP.)
EXISTING TREE, SEE
TREE MITIGATION
PLANS (TYP.)
STORMWATER
POND
PROPERTY
BOUNDARY (TYP.)
FORT FLORIDA
ROAD
FO
R
T FLO
R
ID
A R
O
AD
SOD
25' WETLAND BUFFER LINE /
25' AVG. 15' MIN., TYP.
EXISTING
TREE
TRUE GRID PERVIOUS
PARKING AREA WITH
STABILIZED GRASS
EXISTING FLOODPLAIN LINE,
TYP.
TRANSFORMER, SEE
ELECTRICAL PLANS
TRUE GRID PERVIOUS
PARKING AREA WITH
STABILIZED GRASS
RETAINING WALL, TYP.
LIGHT POLE , TYP.
SEE ELECTRICAL PLANS
1.36%
LF
O F
" H
P S
TO
RM P
P @
9.
LF
O
F
" R C
P
.8
3%
LF
O F 12
" H
P STORM PP @
0.
7 L F O
F 12 " H
P STORM PP @
0.
1 LF OF 12" HP STORM PP @ 0.00%
LF
O
F 8"
P
VC
.0 0%
83 LF OF 8" PVC @
0.00%
LF
O
F 8"
P
ER
FO
R
R
AT
ED
P
IP
E
.0 0%
42 LF OF 12" HP STORM PP @ 0.00%
L
F O
F 8"
P
VC
.4 6%
LF
O
F 8"
P
ER
FO
R
R
AT
ED
P
IP
E
.0 0%
42 LF OF 12" HP STORM PP @ 0.00%
63 LF OF 8" PVC @ 0.00%
34 LF OF 12" HP STORM PP @ 0.00%
W W W
W W W
W
W
W
W
W
WWWWWW
W W
W W
W W
W W
W
W
W
W
RW RW
R W
R W
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
FM
TT
PO
6,504 sf
PA
PA
270 sf
VOS
ZF
MC
VOS
AF
MCW
ZF
DI
IP
AF
LE
QV
VOS
LE
VOS
MC
LE
MC
VOS
LE
TDN
QV
VOS
MCMC
LE
VOS
LE
VOS
MC
VO
DI
2,306 sf
PA
VO
LE
LE
TD
QV
TD1
TD1
VOS
MC
22 AF
VOS
MC
SP1
VOS
VO
DI
DISP2
VOS
SP3
12,150 sf
PA
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT CAL SIZE REMARKS
CANOPY TREE
AF 7 FLORIDA FLAME RED MAPLE ACER RUBRUM 'FLORIDA FLAME' FG 3" CAL. 14` HT., 5` SPR. STRAIGHT, SINGLE LEADER, FULL, FL #1
PO 3 AMERICAN SYCAMORE PLATANUS OCCIDENTALIS F.G. 3" CAL. 14` HT., 6` SPR. STRAIGHT, SINGLE LEADER, FULL, FL #1
QV 10 SOUTHERN LIVE OAK QUERCUS VIRGINIANA FG 3" CAL. 14` HT., 6` SPR. STRAIGHT, SINGLE LEADER, FULL, FL #1
QV2 4 SOUTHERN LIVE OAK QUERCUS VIRGINIANA FG 7" CAL MIN 20` HT STRAIGHT, SINGLE LEADER, FULL, FL #1, 5' CT., SPECIMEN QUALITY
TD1 8 BALD CYPRESS TAXODIUM DISTICHUM FG 3" CAL MIN 12` HT., 5` SPR. SINGLE, STRAIGHT, FL #1, FULL
PALM TREES
SP1 7 SABAL PALM SABAL PALMETTO FG 10` CT STRAIGHT, SINGLE LEADER, FL #1, FULL, FULLY
REGENERATED
SP2 7 SABAL PALM SABAL PALMETTO FG 14` CT STRAIGHT, SINGLE LEADER, FL #1, FULL, FULLY
REGENERATED
SP3 7 SABAL PALM SABAL PALMETTO FG 18` CT STRAIGHT, SINGLE LEADER, FL #1, FULL, FULLY
REGENERATED
SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT SIZE SPACING REMARKS
SHRUBS
CBB 25 AMERICAN BEAUTYBERRY CALLICARPA AMERICANA 7 GAL 18" FULL SEE PLAN FULL
IP 103 FLORIDA ANISE ILLICIUM FLORIDANUM 3 GAL 36" FULL 36" OC FULL
MCW 7 WAX MYRTLE MYRICA CERIFERA 30 GAL 60" HT SEE PLAN FULL TO GROUND
SR 122 SAW PALMETTO SERENOA REPENS 3 GAL 30" FULL 36" OC FULL, SPECIMEN QUALITY
TD 80 FAKAHATCHEE GRASS TRIPSACUM DACTYLOIDES 3 GAL 30" FULL 48" OC FULL
TDN 253 DWARF FAKAHATCHEE GRASS TRIPSACUM DACTYLOIDES NANA 3 GAL 18" FULL 36" OC FULL
PLANT SCHEDULE
VO 114 SWEET VIBURNUM VIBURNUM ODORATISSIMUM 7 GAL 30" HT 30" OC FULL
ZF 37 CARDBOARD PALM ZAMIA FURFURACEA 7 GAL 30" HT 48" OC FULL
SHRUB AREAS
DI 338 AFRICAN IRIS DIETES IRIDIOIDES 3 GAL 24" FULL 24" OC FULL, SYMMETRIAL APPEARANCE
DTB 139 VARIEGATED BLUEBERRY FLAX LILY DIANELLA TASMANICA `BLUEBERRY` 3 GAL 12" FULL 24" OC FULL, VARIEGATED
MC 399 PINK MUHLY GRASS MUHLENBERGIA CAPILLARIS 3 GAL 24" FULL 30" OC FULL
VOS 477 MISS SCHILLERS DELIGHT VIBURNUM VIBURNUM OBOVATUM 'MISS SCHILLERS DELIGHT' 3 GAL 24" FULL 30" OC FULL
ZP 281 COONTIE CYCAD ZAMIA PUMILA 7 GAL 30" FULL 30" OC FULL
GROUND COVERS
LE 778 EMERALD GODDESS LILYTURF LIRIOPE MUSCARI 'EMERALD GODDESS' 1 GAL 12" SPRD MIN 18" OC FULL
LM2 144 TRAILING PURPLE LANTANA LANTANA MONTEVIDENSIS 'TRAILING PURPLE' 1 GAL 12" SPRD MIN 18" OC FULL
SOD
PA 43,437 SF ARGENTINE BAHIA GRASS PASPALUM NOTATUM 'ARGENTINE' SOD - - ROLLED TIGHT, 100%
WEED/INSECT/DIESEASE/DEBRIS FREE
1 2 7
AL
EX
AN
D
ER
IS
LA
N D
PA
R
K
- P
H
AS
E
PR
EP
AR
ED
F O
R
C
IT
Y O
F D
EB
AR
Y
LA
N D
SC
AP
E
PL
AN
L1.02
Know what'sbelow.
Callbefore you dig.
CALL 2 WORKING DAYS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
NORTH
MATCHLINE; SEE SHEET L1.01
SOD
SOD
SOD
MAINTAIN EXISTING
VEGETATION
BENEATH EXISTING
TREES
SOD
MAINTAIN
EXISTING
VEGETATION
BENEATH
EXISTING
TREES
FO
R
T FLO
R
ID
A R
O
AD
TRUE GRID PERVIOUS
PARKING AREA WITH
STABILIZED GRASS
STABALIZED
GRAVEL PARKING
LOT
RIGHT-OF-WAY
EDGE OF WETLAND, TYP.EDGE OF WETLAND, TYP.
EXISTING OVERHEAD
UTILITIES, TYP.
EXISTING TREE, SEE
TREE MITIGATION
PLANS (TYP.)
PROPERTY BOUNDARY (TYP.)
STORMWATER
POND
STORMWATER
SWALE
SOD
CONTRACTOR TO
COORDINATE RELOCATION
OF POWER POLE TO
ACCOMODATE DRIVEWAY.
RETAINING WALL, TYP.
25' WETLAND BUFFER LINE /
25' AVG. 15' MIN., TYP.
SOD
SOD
MISC. QTY BOTANICAL/COMMON NAME SPECIFICATIONS
MULCH TBD DESIGNER BROWN HARDWOOD MULCH 3" DEPTH MINIMUM, SHREDDED, FREE OF WEEDS/INVASIVE PLANT MATERIAL
LANDSCAPE NOTES:
- BAHIA SOD TO BE APPLIED TO ALL DISTURBED AREAS
TRUE GRID PERVIOUS
PARKING AREA WITH
STABILIZED GRASS
TRANSFORMER, SEE
ELECTRICAL PLANS
LIGHT POLE , TYP.
SEE ELECTRICAL PLANSEXISTING FLOODPLAIN LINE,
TYP.
MAINTAIN EXISTING
VEGETATION
BENEATH EXISTING
TREES
RESTROOM
BUILDING
OP.
BUILDING
LIFT
STATION
STORAGE
GARAGE
1 2 7
AL
EX
AN
D
ER
IS
LA
N D
PA
R
K
- P
H
AS
E
PR
EP
AR
ED
F O
R
C
IT
Y O
F D
EB
AR
Y
LA
N D
SC
AP
E D
ET
AI
LS
L1.50
3X ROOTBALL WIDTH MIN.
6"
12" TYP.
TRUNK/ROOT BALL TO BE CENTERED AND
PLUMB/LEVEL IN PLANTING PIT.
6" DIA. CLEAR OF MULCH AT TRUNK FLARE.2
3" MINIMUM MULCH AS SPECIFIED. WHERE
TREES ARE PLACED IN SOD, MULCH RING
FOR TREES SHALL BE 6' DIAMETER (MIN.) OR
AS DIRECTED BY OWNER'S REPRESENTATIVE.
4" HIGH BERM, FIRMLY COMPACTED.4
TREE FROG ANCHOR SYSTEM INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS.
FINISHED GRADE. (SEE GRADING PLAN)6
TOP OF ROOTBALL MIN. 1" ABOVE FINISHED
GRADE.
PREPARED PLANTING SOIL AS SPECIFIED.8
TOP OF ROOTBALL SHALL BE 1" ABOVE
FINISHED GRADE. ROOTBALLS GREATER
THAN 24" DIAMETER SHALL BE PLACED ON
MOUND OF UNDISTURBED SOIL TO PREVENT
SETTLING. ROOTBALLS SMALLER THAN 24" IN
DIAMETER MAY SIT ON COMPACTED EARTH.
UNDISTURBED NATIVE SOIL.10
SCARIFY BOTTOM AND SIDES OF PLANTING
PIT.
TREE PLANTING
SECTION / PLAN
PLAN
SECTION
MULCH/TOPSOIL BACKFILL
ROOTBALL AND TRUNK
TREE STABILIZATION AND
FERTILIZATION SYSTEM
NOTES:
A. FINAL TREE STAKING DETAILS AND PLACEMENT TO
BE APPROVED BY OWNER.
B. REMOVE BURLAP, WIRE AND STRAPS (ANYTHING
THAT COULD GIRDLE TREE OR RESTRICT ROOT
GROWTH) ON UPPER 1/3 OF ROOTBALL.
C. PRUNE ALL TREES IN ACCORDANCE WITH ANSI
A-300.
NTS
L1.50
TREE PLANTING ON A SLOPE
SECTION / PLAN NTS
PLAN
SECTION
MULCH/TOPSOIL BACKFILL
ROOTBALL AND TRUNK
TREE STABILIZATION AND
FERTILIZATION SYSTEM
NOTES:
A. FINAL TREE STAKING DETAILS AND PLACEMENT TO
BE APPROVED BY OWNER.
B. REMOVE BURLAP, WIRE AND STRAPS (ANYTHING
THAT COULD GIRDLE TREE OR RESTRICT ROOT
GROWTH) ON UPPER 1/3 OF ROOTBALL.
C. PRUNE ALL TREES IN ACCORDANCE WITH ANSI
A-300.
3X ROOTBALL
WIDTH MIN.
6"
12" TYP.
TRUNK/ROOT BALL TO BE CENTERED AND
PLUMB/LEVEL IN PLANTING PIT.
6" DIA. CLEAR OF MULCH AT TRUNK FLARE.2
3. 4" HIGH BERM, FIRMLY COMPACTED.3
3" MINIMUM OF HARDWOOD BARK MULCH
AS SPECIFIED. WHERE TREES ARE PLACED
IN SOD, MULCH RING FOR TREES SHALL BE
6' DIAMETER (MIN.) OR AS DIRECTED BY
OWNER'S REPRESENTATIVE.
TREE FROG ANCHOR SYSTEM INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS.
4" MIN. OF TOPSOIL TO BRING TO FINISHED
GRADE. (SEE GRADING PLAN)
TOP OF ROOTBALL MIN. 1" ABOVE FINISHED
GRADE.
PREPARED PLANTING SOIL AS SPECIFIED.8
ROOTBALLS GREATER THAN 24" DIAMETER
SHALL BE PLACED ON MOUND OF
UNDISTURBED SOIL TO PREVENT SETTLING.
ROOTBALLS SMALLER THAN 24" IN
DIAMETER MAY SIT ON COMPACTED EARTH.
UNDISTURBED NATIVE SOIL.10
SCARIFY BOTTOM AND SIDES OF PLANTING
PIT.
CUT BACK SLOPE TO PROVIDE A FLAT
SURFACE FOR PLANTING.
L1.50
MAINTAIN 12" DEAD ZONE
AT BED EDGE.
REFER TO PLANT
SCHEDULE FOR SPACING.
BEST FACE OF SHRUB/
GROUNDCOVER TO FACE
FRONT OF PLANTING BED.
X X
NOTES:
A. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.
B. WHEN SHRUBS ARE PRUNED IN MASSES, PRUNE ALL SHRUBS TO ACHIEVE UNIFORM MASS / HEIGHT.
C. ALL SHRUBS AND GROUNDCOVERS SHALL BE PLUMB VERTICALLY, UNLESS OTHERWISE DIRECTED BY OWNERS
REPRESENTATIVE.
4" TY
P.
4"
TYP.
3X ROOT BALL WIDTH
MINIMUM
'X'
SHRUB/GROUNDCOVER PLANTING
SECTION / PLAN NTS
PLAN
SECTION
TOP OF SHRUB ROOTBALLS TO
BE PLANTED 1" - 2" HIGH WITH
SOIL MOUNDING UP TO THE TOP
OF ROOTBALL.
PRUNE ALL SHRUBS TO
ACHIEVE A UNIFORM
MASS/HEIGHT.
3" MULCH LAYER AS
SPECIFIED.
EXCAVATE ENTIRE BED
SPECIFIED FOR GROUNDCOVER
BED.
FINISHED GRADE (SEE
GRADING PLAN).
PREPARED PLANTING SOIL AS
SPECIFIED. (SEE LANDSCAPE
NOTES) NOTE: WHEN GROUND-
COVERS AND SHRUBS USED IN
MASSES, ENTIRE BED TO BE
AMENDED WITH PLANTING SOIL
MIX AS SPECIFIED.
SCARIFY OF PLANTING PIT
SIDES AND BOTTOM.
4" HIGH BERM FIRMLY
COMPACTED.
UNDISTURBED NATIVE SOIL.9
FERTILIZER TABLETS (MAX 3"
DEEP)
L1.50
NOTES:
A. EXCAVATE A CONTINUOUS 24" DEEP PIT (FROM TOP OF CURB) FOR ENTIRE LENGTH AND WIDTH OF
ISLAND & BACKFILL WITH APPROVED PLANTING MIX.
B. PROTECT AND RETAIN ALL CURBS AND BASE. COMPACTED SUBGRADE TO REMAIN FOR STRUCTURAL
SUPPORT OF CURB SYSTEM (TYP).
C. ALL ISLANDS SHALL UTILIZE POOR DRAINAGE DETAIL WHEN PERCOLATION RATES ARE 2" PER HOUR
OR LESS.
WIDTH VARIES - SEE PLANS
SEE NOTE
PLANTED PARKING LOT ISLANDS/MEDIANS
SECTION NTS
CROWN ISLANDS @ 5:1 SLOPES (OR AS SPECIFIED ON THE LANDSCAPE PLANS).1
CLEAR ZONE: 36" MIN. FROM BACK OF CURB TO CENTER OF NEAREST SHRUB. CLEAR
ZONE SHALL CONTAIN 3" CONTINUOUS MULCH OR TURF, SEE PLANS.
2" MIN VERTICAL CLEARANCE, TOP OF CURB TO TOP OF MULCH.3
L1.50
EXISTING GRADE
(DASHED)
NOTES:
A. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING
PITS PRIOR TO INSTALLATION.
B. WHEN SHRUBS ARE PRUNED IN MASSES, PRUNE ALL SHRUBS TO
ACHIEVE UNIFORM MASS / HEIGHT.
C. ALL SHRUBS AND GROUNDCOVERS SHALL BE PLUMB
VERTICALLY, UNLESS OTHERWISE DIRECTED BY OWNERS
REPRESENTATIVE.
4" T
YP
4" TYP.
3X ROOT BALL
WIDTH MINIMUM
SHRUB/GROUNDCOVER PLANTING ON A SLOPE
SECTION NTS
TOP OF SHRUB ROOTBALLS TO BE
PLANTED 1" - 2" HIGH WITH SOIL
MOUNDING UP TO THE TOP OF
ROOTBALL.
PRUNE SHRUBS AS DIRECTED BY
OWNER'S REPRESENTATIVE.
3" MINIMUM OF MULCH AS
SPECIFIED. WHERE SHRUBS ARE
PLACED IN MASSES, MULCH SHALL
BE SPREAD IN A CONTINUOUS BED.
SOIL BERM TO HOLD WATER. TOP
OF PLANTING PIT 'BERM' TO BE
LEVEL ACROSS PIT. SLOPE
DOWNHILL PORTION OF BERM AS
REQUIRED TO MEET EXISTING
GRADE. MULCH OVER EXPOSED
TOPSOIL.
FINISHED GRADE (SEE GRADING
PLAN)
PREPARED PLANTING SOIL AS
SPECIFIED. (SEE LANDSCAPE
NOTES).
SCARIFY SIDES AND BOTTOM OF
PLANTING PIT.
FERTILIZER TABLETS (MAX 3"
DEEP).
UNDISTURBED NATIVE SOIL9
L1.50
NOTES:
1. CLEAR ZONE: 36" MIN. FROM BUILDING TO CENTER OF NEAREST SHRUB.
2. INSTALL SPECIFIED MULCH: 24" MIN. FROM BUILDING. SPECIFIED MULCH TO BE INSTALLED AT
A DEPTH OF 3" (MIN.)
PLANTINGS ADJACENT TO BUILDINGS
SECTION NTS
24" MIN. CLEAR
MIN. 1/2
MATURE
SHRUB WIDTH
BUILDING
SPECIFIED
MULCH
L1.50
2'-0"
MIN. CLR.
MIN. 1/2 MATURE
SHRUB WIDTH
PARKING SPACE/CURB PLANTING
SECTION NTS
INSTALL CONTINUOUS MULCH BED ADJACENT TO PARKING SPACES AS SHOWN.
MULCH SHALL BE MIN. 3" DEEP. NO POP-UP IRRIGATION HEADS SHALL BE
LOCATED WITHIN 24" OF A PARKING SPACE ON ANY SIDE.
CURB / PARKING LOT EDGE.2
L1.50
4' -0
7'
-6
7'-6" 7'-6"
7'-6"
MIN. 12 MATURE
SHRUB WIDTH
MIN. 15' CLEAR
MIN. 12 MATURE
SHRUB WIDTH
FIRE HYDRANT
SHRUB PLANTING AT FIRE HYDRANT
SECTION / PLAN NTS
PLAN
SECTION
FIRE HYDRANT.1
NO PLANT EXCEEDING 12"
MATURE HEIGHT
MATERIAL SHALL BE
PLACED WITHIN SHOWN
RADIUS OF ALL
PROPOSED OR EXISTING
FIRE HYDRANTS.
CONTRACTOR SHALL
ADJUST PLANT
MATERIAL SO THAT NO
CONFLICTS WITH FIRE
HYDRANTS OCCUR ON
SITE.
FRONT OF HYDRANT
(TOWARD CURB)
L1.50
+H.P.
LIMITS OF PLANTING
PIT
NOTES:
A. THIS DETAIL SHALL BE IMPLEMENTED WHERE
PERCOLATION RATES ARE 2" PER HOUR OR
LESS.
B. CONTRACTOR TO PERFORM PERCOLATION TEST
AS REQUIRED. AND NOTIFY OWNER/LANDSCAPE
ARCHITECT.
C. SEE TYPICAL TREE PLANTING DETAIL THIS SHEET
FOR PLANT STAKING.
3X ROOTBALL
DIAMETER
VA
R
IE
S
POOR DRAINAGE CONDITION
SECTION / PLAN NTS
PLAN
SECTION
FINISH GRADE (SEE GRADING PLANS).1
BACKFILL WITH PREPARED PLANTING
SOIL MIX AS SPECIFIED.
FILTER CLOTH, MIRAFI 500X OR BETTER.3
SLOPE BOTTOM TO DRAIN.4
AUGURED HOLE Ø ±18" PENETRATE
THROUGH OCCLUDING LAYER TO WATER
TABLE OR TO A DEPTH OF 7' TO ASSURE
PROPER PERCOLATION.
BACKFILL WITH 1/2" - 3/4" GRAVEL TO
REQUIRED DEPTH THROUGH OCCLUDING
LAYER TO ASSURE PROPER
PERCOLATION.
WATER TABLE. (DEPTH VARIES)7
UNDISTURBED NATIVE SOIL.8
SET ROOTBALL ON UNDISTURBED STABLE
SUBSOIL SO THAT TOP OF ROOT BALL IS
1" ABOVE FINISHED GRADE.
ROOTBALL
TRUNK
L1.50
INSTALLATION NOTES:
NOTE: IF WIRE TIES ARE USED, AVOID DIRECT CONTACT WITH
FENCE. WIRE MAY DAMAGE FENCE OVER TIME.
A. POST SELECTION SHOULD BE BASED ON EXPECTED
STRENGTH NEEDS AND THE LENGTH OF TIME FENCE WILL
BE IN PLACE. FLEXIBLE FIBERGLASS ROD POSTS ARE
RECOMMENDED FOR PARKS, ATHLETIC EVENTS AND
CROWD CONTROL INSTALLATIONS. METAL "T" POSTS OR
TREATED WOOD POSTS ARE TYPICALLY USED FOR
CONSTRUCTION AND OTHER APPLICATIONS.
B. POSTS SHOULD BE DRIVEN INTO THE GROUND TO A DEPTH
OF 1/3 OF THE HEIGHT OF THE POST. FOR EXAMPLE, A 6'
POST SHOULD BE SET AT LEAST 2' INTO THE GROUND.
C. SPACE POSTS EVERY 6' (MIN.) TO 8' (MAX.).
D. SECURE FENCING TO POST WITH NYLON CABLE TIES
(AVAILABLE FROM CONWED PLASTICS). WOOD STRIPS MAY
BE ALSO BE USED TO PROVIDE ADDITIONAL SUPPORT AND
PROTECTION BETWEEN TIES AND POSTS.
6'-8"oc
6' M
IN
CORNER
CONNECTION
CONNECTION
TREE PROTECTION FENCING
ELEVATION / PLAN NTS
6'H "PERIMETER PLUS" CONSTRUCTION
FENCE BY CONWED PLASTICS OR OWNER'S
REPRESENTATIVE APPROVED EQUAL.
SUBMIT PRODUCT INFORMATION FOR
APPROVAL PRIOR TO INSTALLATION.
8' TALL METAL "T" POSTS OR 2" x 2" X 8'
PRESSURE TREATED WOOD POSTS WITH 24"
BURIAL BELOW GRADE.
ELEVATION
PLAN
DRIPLINE
(TYP.)
DRIPLINE
(TYP.)
L1.50
10 PALM PLANTING
SECTION / PLAN NTS
OA =OVERALL PALM
HEIGHT (MEASURED
TO TOP OF BUD)
CT =CLEAR TRUNK
(MEASURED TO
BOTTOM OF
LEAF SHEATHS)
GW =GRAY WOOD
(MEASURED TO TOP
OF HARDENED
TRUNK)
NOTES:
A. FINAL TREE STAKING DETAILS AND PLACEMENT
TO BE APPROVED BY OWNER.
B. ALL TREE STAKING IS TO BE WITHIN MULCH BED
AREA OUTSIDE TREE PIT.
C. CONTRACTOR SHALL ASSURE PERCOLATION OF
ALL PLANTING PITS PRIOR TO INSTALLATION -
REFER TO POOR DRAINAGE CONDITION DETAIL.
O A
C T
/ G W
12"
6"
PLAN
SECTION
5 LAYERS OF BURLAP TO PROTECT
TRUNK.
FIVE 2" X 4" X 18" WOOD BATTENS.2
SECURE BATTENS WITH 2- 3/4" CARBON
STEEL BANDS TO HOLD BATTENS IN
PLACE. NO NAILS SHALL BE DRIVEN INTO
PALM. HEIGHT OF BATTENS SHALL BE
LOCATED IN RELATION TO THE HEIGHT OF
THE PALM FOR ADEQUATE BRACING.
(3) 2"X4"X8' SUPPORTS. NAIL (DRILL AN
NAIL IF NECESSARY) TO BATTENS AND 2"
4" STAKES. STAIN DARK BROWN.
3" SPECIFIED MULCH5
BERM SOIL TO HOLD WATER.6
FINISH GRADE7
2X4X24" (MIN) P.T. WOOD STAKES (TYP.)
NAIL TO SUPPORT POLES.
PREPARED PLANTING SOIL AS SPECIFIED.
(SEE LANDSCAPE NOTES).
L1.50
1. BASE OF TREE SHALL BE PLANTED SLIGHTLY ABOVE
(1" MIN.) ADJACENT FINISH GRADE. REMOVE ALL
TWINE & STRAPS & CUT BURLAP FROM TOP 1/3 OF
ROOT BALL. NO SYNTHETIC BURLAP WILL BE
ACCEPTED.
2. 4" SHREDDED HARDWOOD MULCH OR APPROVED
EQUAL.
3. DIAMETER OF TREE PIT TO BE TWICE THE DIAMETER
OF ROOT BALL-ROUGHEN SIDES OF TREE PIT.
4. 3" HIGH SOIL BERM TO HOLD WATER.
5. TOPSOIL MIX BACKFILL.
6. TREE WRAP.
7. 4" MIN. OF TOPSOIL TO BRING TO FINISHED GRADE
(SEE GRADING PLAN).
8. ROOT BALLS GREATER THAN 24" DIAMETER SHALL
BE PLACED ON MOUND OF UNDISTURBED SOIL TO
PREVENT SETTLING ROOT BALLS SMALLER THAN 24"
IN DIA. MAY SIT ON COMPACTED EARTH.
9. UNDISTURBED SUBSOIL.
10. PREPARE PLANTING SOIL AS SPECIFIED.
11. Tree Frog® RBK40pt FOR UP TO 4" TREE CALIPER OR
Tree Frog® RBK60pt FOR GREATER THAN 4" AND UP
TO 6" TREE CALIPER. REFER TO SITEWORK
SPECIFICATIONS FOR APPROVED MATERIALS AND
INSTALLATION REQUIREMENTS.
PLAN
SECTION
NOTES:
A. FINAL TREE STAKING DETAILS AND PLACEMENT TO BE
APPROVED BY OWNER.
B. SET TREE AT ORIGINAL DEPTH. REMOVE BURLAP, WIRE AND
STRAPS (ANYTHING THAT COULD GIRDLE TREE OR RESTRICT
ROOT GROWTH) ON UPPER 1/3 OF ROOTBALL.
C. SEE LANDSCAPE NOTES FOR THE TYPE OF MULCH MATERIAL
TO USE.
D. PRUNE TREE AS DIRECTED BY LANDSCAPE ARCHITECT
E. ASSURE PERCOLATION OF ALL PLANTING PITS
O
VE
R
AL
L H
EI
G
H T
(O .H
C
LE
AR
T
R U
N K
(C .T
H
EI
G
H T
12"
TYP.
TREE STAKING
MULCH/
TOPSOIL
BACKFILL
ROOTBALL
AND TRUNK
MULTI-TRUNK TREE PLANTING
SECTION/PLAN NTS
L1.50
EX
AN
D
ER
IS
LA
N D
PA
R
K
- P
H
AS
E
PR
EP
AR
ED
F O
R
C
IT
Y O
F D
EB
AR
Y
LA
N
D
SC
AP
E
AN
D
IR
R
IG
AT
IO
N
SP
EC
IF
IC
AT
IO
N S
L1.51
A. SCOPE OF WORK
1. THE WORK CONSISTS OF: FURNISHING ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, TRANSPORTATION, AND ANY OTHER APPURTENANCES NECESSARY FOR THE COMPLETION OF THIS PROJECT AS SHOWN ON THE DRAWINGS, AS INCLUDED IN THE PLANT LIST, AND AS SPECIFIED
HEREIN.
2. WORK SHALL INCLUDE MAINTENANCE AND WATERING OF ALL CONTRACT PLANTING AREAS UNTIL CERTIFICATION OF ACCEPTANCE BY THE
OWNER.
B. PROTECTION OF EXISTING STRUCTURES
1. ALL EXISTING BUILDINGS, WALKS, WALLS, PAVING, PIPING, OTHER SITE CONSTRUCTION ITEMS, AND PLANTING ALREADY COMPLETED OR ESTABLISHED AND DESIGNATED TO REMAIN SHALL BE PROTECTED FROM DAMAGE BY THE CONTRACTOR UNLESS OTHERWISE SPECIFIED. ALL DAMAGE RESULTING FROM NEGLIGENCE SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER, AT NO COST TO THE
OWNER.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL NECESSARY BMP DEVICES ACCORDING TO ALL REGULATORY AGENCY'S
STANDARDS THROUGH THE DURATION OF ALL CONSTRUCTION ACTIVITIES.
3. THE CONTRACTOR SHALL SUBMIT A DETAILED PROJECT SPECIFIC WORK ZONE TRAFFIC CONTROL PLAN UNLESS THE WORK REQUIRES NOTHING MORE THAN A DIRECT APPLICATION OF FDOT DESIGN STANDARDS, INDEX 600. IF A DIRECT APPLICATION OF INDEX 600 IS PROPOSED, THE CONTRACTOR SHALL SUBMIT IN WRITING A STATEMENT INDICATING THE STANDARD INDEX AND PAGE NUMBER NO LESS THAN 10 BUSINESS DAYS PRIOR TO START OF CONSTRUCTION. WHEN A DIRECT APPLICATION OF FDOT STANDARD INDEX 600 IS NOT ACCEPTABLE A PROJECT SPECIFIC WORK ZONE TRAFFIC CONTROL PLAN SHALL BE PREPARED BY A FLORIDA PROFESSIONAL ENGINEER WHO HAS SUCCESSFULLY COMPLETED ADVANCED TRAINING IN MAINTENANCE OF TRAFFIC, AS DEFINED BY FDOT FOR APPROVAL BY THE COUNTY ENGINEER'S
REPRESENTATIVE.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UTILITIES, WHETHER PUBLIC OR PRIVATE, PRIOR TO EXCAVATION. THE INFORMATION AND DATA SHOWN WITH RESPECT TO EXISTING UNDERGROUND FACILITIES AT OR CONTIGUOUS TO THE SITE IS APPROXIMATE AND BASED ON INFORMATION FURNISHED BY THE OWNER OF SUCH UNDERGROUND FACILITIES OR ON PHYSICAL APPURTENANCES OBSERVED IN THE FIELD. THE OWNER AND DESIGN PROFESSIONAL SHALL NOT BE RESPONSIBLE FOR THE ACCURACY AND COMPLETENESS OF ANY SUCH INFORMATION OR DATA. THE CONTRACTOR SHALL HAVE FULL RESPONSIBILITY FOR; REVIEWING AND CHECKING ALL SUCH INFORMATION AND DATA; LOCATING ALL UNDERGROUND FACILITIES DURING CONSTRUCTION; THE SAFETY AND PROTECTION THEREOF; REPAIRING ANY DAMAGE THERETO RESULTING FROM THE WORK. THE COST OF ALL WILL BE CONSIDERED AS HAVING BEEN INCLUDED IN THE CONTRACT PRICE. THE CONTRACTOR SHALL NOTIFY ANY AFFECTED UTILITY COMPANIES OR AGENCIES IN WRITING AT LEAST 48 HOURS PRIOR TO BEGINNING
CONSTRUCTION.
C. PROTECTION OF EXISTING PLANT MATERIALS
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UNAUTHORIZED CUTTING OR DAMAGE TO TREES AND SHRUBS EXISTING OR OTHERWISE, CAUSED BY CARELESS EQUIPMENT OPERATION, MATERIAL STOCKPILING, ETC... THIS SHALL INCLUDE COMPACTION BY DRIVING OR PARKING INSIDE THE DRIP-LINE AND SPILLING OIL, GASOLINE, OR OTHER DELETERIOUS MATERIALS WITHIN THE DRIP-LINE. NO MATERIALS SHALL BE BURNED ON SITE. EXISTING TREES KILLED OR DAMAGED SO THAT THEY ARE MISSHAPEN AND/OR UNSIGHTLY SHALL BE REPLACED AT THE COST TO THE CONTRACTOR OF THREE HUNDRED DOLLARS ($300) PER CALIPER INCH ON AN ESCALATING SCALE WHICH ADDS AN ADDITIONAL TWENTY
(20) PERCENT PER INCH OVER FOUR (4) INCHES CALIPER AS FIXED AND AGREED LIQUIDATED DAMAGES. CALIPER SHALL BE MEASURED SIX (6) INCHES ABOVE GROUND LEVEL FOR TREES UP TO AND INCLUDING FOUR (4) INCHES IN CALIPER AND TWELVE (12) INCHES ABOVE GROUND LEVEL
FOR TREES OVER FOUR (4) INCHES IN CALIPER.
2. SEE TREE MITIGATION PLAN AND NOTES, IF APPLICABLE.
D. MATERIALS
1. GENERAL
MATERIAL SAMPLES LISTED BELOW SHALL BE SUBMITTED FOR APPROVAL, ON SITE OR AS DETERMINED BY THE OWNER. UPON APPROVAL, DELIVERY OF MATERIALS MAY COMMENCE.
MATERIAL SAMPLE SIZE
MULCH ONE (1) CUBIC FOOT
TOPSOIL MIX ONE (1) CUBIC FOOT
PLANTS ONE (1) OF EACH VARIETY (OR TAGGED IN NURSERY)
2. PLANT MATERIALS
a. PLANT SPECIES AND SIZE SHALL CONFORM TO THOSE INDICATED ON THE DRAWINGS. ALL NURSERY STOCK SHALL BE IN ACCORDANCE WITH GRADES AND STANDARDS FOR NURSERY PLANTS, LATEST EDITION, PUBLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. ALL PLANTS SHALL BE FLORIDA GRADE NO. 1 OR BETTER AS DETERMINED BY THE FLORIDA DIVISION OF PLANT INDUSTRY.
ALL PLANTS SHALL BE HEALTHY, VIGOROUS, SOUND, WELL-BRANCHED, AND FREE OF DISEASE AND INSECTS, INSECT EGGS AND LARVAE AND SHALL HAVE ADEQUATE ROOT SYSTEMS. TREES FOR PLANTING IN ROWS SHALL BE UNIFORM IN SIZE AND SHAPE. ALL MATERIALS SHALL BE SUBJECT TO APPROVAL BY THE OWNER. WHERE ANY REQUIREMENTS ARE OMITTED FROM THE PLANT LIST, THE PLANTS FURNISHED SHALL BE NORMAL FOR THE VARIETY. PLANTS SHALL BE PRUNED PRIOR TO DELIVERY ONLY WITH APPROVAL FROM OWNER OR OWNER'S REPRESENTATIVE. NO SUBSTITUTIONS SHALL BE MADE WITHOUT WRITTEN PERMISSION FROM THE OWNER'S REPRESENTATIVE.
b. MEASUREMENTS: THE HEIGHT AND/OR WIDTH OF TREES SHALL BE MEASURED FROM THE GROUND OR ACROSS THE NORMAL SPREAD OF BRANCHES WITH THE PLANTS IN THEIR NORMAL POSITION. THIS MEASUREMENT SHALL NOT INCLUDE THE IMMEDIATE TERMINAL GROWTH.
PLANTS LARGER IN SIZE THAN THOSE SPECIFIED IN THE PLANT LIST MAY BE USED IF APPROVED BY THE OWNER. IF THE USE OF LARGER PLANTS IS APPROVED, THE BALL OF EARTH OR SPREAD OF ROOTS SHALL BE INCREASED IN PROPORTION TO THE SIZE OF THE PLANT.
c. INSPECTION: PLANTS SHALL BE SUBJECT TO INSPECTION AND APPROVAL AT THE PLACE OF GROWTH, OR UPON DELIVERY TO THE SITE, AS DETERMINED BY THE OWNER, FOR QUALITY, SIZE, AND VARIETY. SUCH APPROVAL SHALL NOT IMPAIR THE RIGHT OF INSPECTION AND REJECTION AT THE SITE DURING PROGRESS OF THE WORK OR AFTER COMPLETION FOR SIZE AND CONDITION OF ROOT BALLS OR ROOTS, LATENT DEFECTS OR INJURIES. REJECTED PLANTS SHALL BE REMOVED IMMEDIATELY FROM THE SITE. NOTICE REQUESTING INSPECTION SHALL BE SUBMITTED IN
WRITING BY THE CONTRACTOR AT LEAST ONE (1) WEEK PRIOR TO ANTICIPATED DATE.
E. SOIL MIXTURE (PLANTING MEDIUM, PLANTING MIX, TOPSOIL MIX)
1. CONTRACTOR SHALL TEST EXISTING SOIL AND AMEND AS NECESSARY IN ACCORDANCE WITH THE GUIDELINES BELOW:
2. SOIL MIXTURE (PLANTING MEDIUM FOR PLANT PITS) SHALL CONSIST OF TWO PARTS OF TOPSOIL AND ONE PART SAND, AS DESCRIBED BELOW.
CONTRACTOR TO SUBMIT SAMPLES AND PH TESTING RESULTS OF SOIL MIXTURE FOR OWNER'S REPRESENTATIVE APPROVAL PRIOR TO PLANT
INSTALLATION OPERATIONS COMMENCE.
a. TOPSOIL FOR USE IN PREPARING SOIL MIXTURE FOR BACKFILLING PLANT PITS SHALL BE FERTILE, FRIABLE, AND OF A LOAMY CHARACTER;
REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH WEEDS AND OTHER LITTER; FREE OF ROOTS, STUMPS, STONES LARGER THAN 2" IN ANY DIRECTION, AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH. IT SHALL CONTAIN THREE (3) TO FIVE (5) PERCENT
DECOMPOSED ORGANIC MATTER AND HAVE A PH BETWEEN 5.5 AND 7.0.
b. SAND SHALL BE COARSE, CLEAN, WELL-DRAINING, NATIVE SAND.
2. TREES SHALL BE PLANTED IN THE EXISTING NATIVE SOIL ON SITE, UNLESS DETERMINED TO BE UNSUITABLE - AT WHICH POINT THE CONTRACTOR SHALL CONTACT OWNER'S REPRESENTATIVE TO DISCUSS ALTERNATE RECOMMENDATION PRIOR TO PLANTING.
F. WATER
1. WATER NECESSARY FOR PLANTING AND MAINTENANCE SHALL BE OF SATISFACTORY QUALITY TO SUSTAIN ADEQUATE PLANT GROWTH AND SHALL NOT CONTAIN HARMFUL, NATURAL OR MAN-MADE ELEMENTS DETRIMENTAL TO PLANTS. WATER MEETING THE ABOVE STANDARD SHALL BE OBTAINED ON THE SITE FROM THE OWNER, IF AVAILABLE, AND THE CONTRACTOR SHALL BE RESPONSIBLE TO MAKE ARRANGEMENTS FOR ITS USE BY HIS TANKS, HOSES, SPRINKLERS, ETC.... IF SUCH WATER IS NOT AVAILABLE AT THE SITE, THE CONTRACTOR SHALL PROVIDE
SATISFACTORY WATER FROM SOURCES OFF THE SITE AT NO ADDITIONAL COST TO THE OWNER.
* WATERING/IRRIGATION RESTRICTIONS MAY APPLY - REFER TO PROPERTY'S JURISDICTIONAL AUTHORITY.
G. FERTILIZER
CONTRACTOR SHALL PROVIDE FERTILIZER APPLICATION SCHEDULE TO OWNER, AS APPLICABLE TO SOIL TYPE, PLANT INSTALLATION TYPE, AND SITE'S PROPOSED USE. SUGGESTED FERTILIZER TYPES SHALL BE ORGANIC OR OTHERWISE NATURALLY-DERIVED.
* FERTILIZER RESTRICTIONS MAY APPLY - REFER TO PROPERTY'S JURISDICTIONAL AUTHORITY.
H. MULCH
1. MULCH MATERIAL SHALL BE MOISTENED AT THE TIME OF APPLICATION TO PREVENT WIND DISPLACEMENT, AND APPLIED AT A DEPTH OF THREE
(3) INCHES. CLEAR MULCH FROM EACH PLANT'S CROWN (BASE). MULCH SHALL BE "FLORIMULCH," EUCALYPTUS MULCH, OR SIMILAR
SUSTAINABLY HARVESTED MULCH UNLESS SPECIFIED OTHERWISE.
2. PROVIDE A THREE (3) INCH MINIMUM LAYER OF SPECIFIED MULCH OVER THE ENTIRE AREA OF EACH SHRUB BED, GROUND COVER, VINE BED, AND TREE PIT (6' MINIMUM) PLANTED UNDER THIS CONTRACT.
I. DIGGING AND HANDLING
1. PROTECT ROOTS OR ROOT BALLS OF PLANTS AT ALL TIMES FROM SUN, DRYING WINDS, WATER AND FREEZING, AS NECESSARY UNTIL PLANTING.
PLANT MATERIALS SHALL BE ADEQUATELY PACKED TO PREVENT DAMAGE DURING TRANSIT. TREES TRANSPORTED MORE THAN TEN (10) MILES OR WHICH ARE NOT PLANTED WITHIN THREE (3) DAYS OF DELIVERY TO THE SITE SHALL BE SPRAYED WITH AN ANTITRANSPIRANT PRODUCT
("WILTPRUF" OR EQUAL) TO MINIMIZE TRANSPIRATIONAL WATER LOSS.
2. BALLED AND BURLAPPED (B&B), AND FIELD GROWN (FG) PLANTS SHALL BE DUG WITH FIRM, NATURAL BALLS OF SOIL OF SUFFICIENT SIZE TO ENCOMPASS THE FIBROUS AND FEEDING ROOTS OF THE PLANTS. NO PLANTS MOVED WITH A ROOT BALL SHALL BE PLANTED IF THE BALL IS
CRACKED OR BROKEN. PLANTS SHALL NOT BE HANDLED BY STEMS.
3. PLANTS MARKED "BR" IN THE PLANT LIST SHALL BE DUG WITH BARE ROOTS. CARE SHALL BE EXERCISED THAT THE ROOTS DO NOT DRY OUT
DURING TRANSPORTATION AND PRIOR TO PLANTING.
4. PROTECTION OF PALMS: ONLY A MINIMUM OF FRONDS SHALL BE REMOVED FROM THE CROWN OF THE PALM TREES TO FACILITATE MOVING AND HANDLING. CLEAR TRUNK (CT) SHALL BE AS SPECIFIED AFTER THE MINIMUM OF FRONDS HAVE BEEN REMOVED. ALL PALMS SHALL BE BRACED
PER PALM PLANTING DETAIL.
5. EXCAVATION OF TREE PITS SHALL BE PERFORMED USING EXTREME CARE TO AVOID DAMAGE TO SURFACE AND SUBSURFACE ELEMENTS SUCH
AS UTILITIES OR HARDSCAPE ELEMENTS, FOOTERS AND PREPARED SUB-BASES.
J. CONTAINER GROWN STOCK
1. ALL CONTAINER GROWN MATERIAL SHALL BE HEALTHY, VIGOROUS, WELL-ROOTED PLANTS ESTABLISHED IN THE CONTAINER IN WHICH THEY ARE SOLD. THE PLANTS SHALL HAVE TOPS WHICH ARE OF GOOD QUALITY AND ARE IN A HEALTHY GROWING CONDITION.
2. AN ESTABLISHED CONTAINER GROWN PLANT SHALL BE TRANSPLANTED INTO A CONTAINER AND GROWN IN THAT CONTAINER SUFFICIENTLY LONG ENOUGH FOR THE NEW FIBROUS ROOTS TO HAVE DEVELOPED SO THAT THE ROOT MASS WILL RETAIN ITS SHAPE AND HOLD TOGETHER WHEN REMOVED FROM THE CONTAINER. CONTAINER GROWN STOCK SHALL NOT BE HANDLED BY THEIR STEMS.
3. ROOT BOUND PLANTS ARE NOT ACCEPTABLE AND WILL BE REJECTED.
4. RPG= "ROOTS PLUS GROWER" CONTAINER PRODUCTS SHALL BE USED WHERE SPECIFIED.
K. COLLECTED STOCK
WHEN THE USE OF COLLECTED STOCK IS PERMITTED AS INDICATED BY THE OWNER OR OWNER'S REPRESENTATIVE, THE MINIMUM SIZES OF ROOTBALLS SHALL BE EQUAL TO THAT SPECIFIED FOR THE NEXT LARGER SIZE OF NURSERY GROWN STOCK OF THE SAME VARIETY.
L. NATIVE STOCK
PLANTS COLLECTED FROM WILD OR NATIVE STANDS SHALL BE CONSIDERED NURSERY GROWN WHEN THEY HAVE BEEN SUCCESSFULLY RE-ESTABLISHED IN A NURSERY ROW AND GROWN UNDER REGULAR NURSERY CULTURAL PRACTICES FOR A MINIMUM OF TWO (2) GROWING SEASONS AND HAVE ATTAINED ADEQUATE ROOT AND TOP GROWTH TO INDICATE FULL RECOVERY FROM TRANSPLANTING INTO THE NURSERY ROW.
M. MATERIALS LIST
QUANTITIES NECESSARY TO COMPLETE THE WORK ON THE DRAWINGS SHALL BE FURNISHED BY THE CONTRACTOR. QUANTITY ESTIMATES HAVE BEEN MADE CAREFULLY, BUT THE LANDSCAPE ARCHITECT OR OWNER ASSUMES NO LIABILITY FOR OMISSIONS OR ERRORS. SHOULD A DISCREPANCY OCCUR BETWEEN THE PLANS AND THE PLANT LIST QUANTITY, THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED FOR CLARIFICATION PRIOR TO BIDDING OR INSTALLATION. ALL DIMENSIONS AND/OR SIZES SPECIFIED SHALL BE THE MINIMUM ACCEPTABLE SIZE.
N. FINE GRADING
1. FINE GRADING UNDER THIS CONTRACT SHALL CONSIST OF FINAL FINISHED GRADING OF LAWN AND PLANTING AREAS THAT HAVE BEEN ROUGH GRADED BY OTHERS. BERMING AS SHOWN ON THE DRAWINGS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, UNLESS OTHERWISE
NOTED.
2. THE CONTRACTOR SHALL FINE GRADE THE LAWN AND PLANTING AREAS TO BRING THE ROUGH GRADE UP TO FINAL FINISHED GRADE ALLOWING FOR THICKNESS OF SOD AND/OR MULCH DEPTH. CONTRACTOR SHALL FINE GRADE BY HAND AND/OR WITH ALL EQUIPMENT NECESSARY INCLUDING A GRADING TRACTOR WITH FRONT-END LOADER FOR TRANSPORTING SOIL WITHIN THE SITE.
3. ALL PLANTING AREAS SHALL BE GRADED AND MAINTAINED FOR POSITIVE DRAINAGE TO SURFACE/SUBSURFACE STORM DRAIN SYSTEMS. AREAS ADJACENT TO BUILDINGS SHALL SLOPE AWAY FROM THE BUILDINGS. REFER TO CIVIL ENGINEER'S PLANS FOR FINAL GRADES, IF APPLICABLE.
O. PLANTING PROCEDURES
1. CLEANING UP BEFORE COMMENCING WORK: THE CONTRACTOR SHALL CLEAN WORK AND SURROUNDING AREAS OF ALL RUBBISH OR OBJECTIONABLE MATTER DAILY. ALL MORTAR, CEMENT, AND TOXIC MATERIAL SHALL BE REMOVED FROM THE SURFACE OF ALL PLANT BEDS.
THESE MATERIALS SHALL NOT BE MIXED WITH THE SOIL. SHOULD THE CONTRACTOR FIND SUCH SOIL CONDITIONS BENEATH THE SOIL WHICH WILL IN ANY WAY ADVERSELY AFFECT THE PLANT GROWTH, HE SHALL IMMEDIATELY CALL IT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. FAILURE TO DO SO BEFORE PLANTING SHALL MAKE THE CORRECTIVE MEASURES THE RESPONSIBILITY OF THE CONTRACTOR.
2. VERIFY LOCATIONS OF ALL UTILITIES, CONDUITS, SUPPLY LINES AND CABLES, INCLUDING BUT NOT LIMITED TO: ELECTRIC, GAS (LINES AND TANKS), WATER, SANITARY SEWER, STORMWATER SYSTEMS, CABLE, AND TELEPHONE. PROPERLY MAINTAIN AND PROTECT EXISTING UTILITIES.
CALL SUNSHINE STATE ONE CALL OF FLORIDA, INC. (811) TO LOCATE UTILITIES AT LEAST 48 HOURS PRIOR TO CONSTRUCTION.
3. SUBGRADE EXCAVATION: CONTRACTOR IS RESPONSIBLE TO REMOVE ALL EXISTING AND IMPORTED LIMEROCK AND LIMEROCK SUB-BASE FROM ALL LANDSCAPE PLANTING AREAS TO A MINIMUM DEPTH OF 36" OR TO NATIVE SOIL. CONTRACTOR IS RESPONSIBLE TO BACKFILL THESE PLANTING AREAS TO ROUGH FINISHED GRADE WITH CLEAN TOPSOIL FROM AN ON-SITE SOURCE OR AN IMPORTED SOURCE. IF LIMEROCK OR OTHER ADVERSE CONDITIONS OCCUR IN PLANTED AREAS AFTER 36" DEEP EXCAVATION BY THE CONTRACTOR, AND POSITIVE DRAINAGE CAN NOT BE ACHIEVED, CONTRACTOR SHALL UTILIZE POOR DRAINAGE CONDITION PLANTING DETAIL.
4. FURNISH NURSERY'S CERTIFICATE OF COMPLIANCE WITH ALL REQUIREMENTS AS SPECIFIED HEREIN. INSPECT AND SELECT PLANT MATERIALS
BEFORE PLANTS ARE DUG AT NURSERY OR GROWING SITE.
5. COMPLY WITH APPLICABLE FEDERAL, STATE, COUNTY, AND LOCAL REGULATIONS GOVERNING LANDSCAPE MATERIALS AND WORK. CONFORM TO ACCEPTED HORTICULTURAL PRACTICES AS USED IN THE TRADE. UPON ARRIVAL AT THE SITE, PLANTS SHALL BE THOROUGHLY WATERED AND PROPERLY MAINTAINED UNTIL PLANTED. PLANTS STORED ONSITE SHALL NOT REMAIN UNPLANTED OR APPROPRIATELY HEALED IN FOR A PERIOD EXCEEDING TWENTY-FOUR (24) HOURS. AT ALL TIMES WORKMANLIKE METHODS CUSTOMARY IN GOOD HORTICULTURAL PRACTICES
SHALL BE EXERCISED.
6. THE WORK SHALL BE COORDINATED WITH OTHER TRADES TO PREVENT CONFLICTS. COORDINATE PLANTING WITH IRRIGATION WORK TO ASSURE AVAILABILITY OF WATER AND PROPER LOCATION OF IRRIGATION APPURTENANCES AND PLANTS.
7. ALL PLANTING PITS SHALL BE EXCAVATED TO SIZE AND DEPTH IN ACCORDANCE WITH THE USA STANDARD FOR NURSERY STOCK 260.1, UNLESS SHOWN OTHERWISE ON THE DRAWINGS, AND BACK FILLED WITH THE PREPARED PLANTING SOIL MIXTURE AS SPECIFIED IN SECTION E. TEST ALL TREE PITS WITH WATER BEFORE PLANTING TO ASSURE PROPER DRAINAGE PERCOLATION IS AVAILABLE. NO ALLOWANCE WILL BE MADE FOR LOST PLANTS DUE TO IMPROPER DRAINAGE. IF POOR DRAINAGE EXISTS, UTILIZE "POOR DRAINAGE CONDITION" PLANTING DETAIL. TREES SHALL BE SET PLUMB AND HELD IN POSITION UNTIL THE PLANTING MIXTURE HAS BEEN FLUSHED INTO PLACE WITH A SLOW, FULL HOSE STREAM. ALL PLANTING SHALL BE PERFORMED BY PERSONNEL FAMILIAR WITH PLANTING PROCEDURES AND UNDER THE SUPERVISION OF A QUALIFIED LANDSCAPE FOREMAN. PROPER "JETTING IN" SHALL BE ASSURED TO ELIMINATE AIR POCKETS AROUND THE ROOTS. "JET STICK" OR EQUAL IS
RECOMMENDED.
8. TAKE ALL NECESSARY PRECAUTIONS TO AVOID DAMAGE TO BUILDINGS AND BUILDING STRUCTURES WHILE INSTALLING TREES.
9. SOIL MIXTURE SHALL BE AS SPECIFIED IN SECTION E OF THESE SPECIFICATIONS.
10. TREES AND SHRUBS SHALL BE SET STRAIGHT AT AN ELEVATION THAT, AFTER SETTLEMENT, THE PLANT CROWN WILL STAND ONE (1) TO TWO (2) INCHES ABOVE GRADE. EACH PLANT SHALL BE SET IN THE CENTER OF THE PIT. PLANTING SOIL MIXTURE SHALL BE BACK FILLED, THOROUGHLY
TAMPED AROUND THE BALL, AND SETTLED BY WATER (AFTER TAMPING).
11. AMEND PINE AND OAK PLANT PITS WITH ECTOMYCORRHIZAL SOIL APPLICATION PER MANUFACTURER'S RECOMMENDATION. ALL OTHER PLANT PITS SHALL BE AMENDED WITH ENDOMYCORRHIZAL SOIL APPLICATION PER MANUFACTURER'S RECOMMENDATION. PROVIDE PRODUCT
INFORMATION SUBMITTAL PRIOR TO INOCULATION.
12. FILL HOLE WITH SOIL MIXTURE, MAKING CERTAIN ALL SOIL IS SATURATED. TO DO THIS, FILL HOLE WITH WATER AND ALLOW TO SOAK MINIMUM TWENTY (20) MINUTES, STIRRING IF NECESSARY TO GET SOIL THOROUGHLY WET. PACK LIGHTLY WITH FEET, ADD MORE WET SOIL MIXTURE. DO NOT COVER TOP OF BALL WITH SOIL MIXTURE. ALL BURLAP, ROPE, WIRES, BASKETS, ETC.., SHALL BE REMOVED FROM THE SIDES AND TOPS OF
BALLS, BUT NO BURLAP SHALL BE PULLED FROM UNDERNEATH.
13. TREES SHALL BE PRUNED, AT THE DIRECTION OF THE OWNER OR OWNER'S REPRESENTATIVE, TO PRESERVE THE NATURAL CHARACTER OF THE PLANT. ALL SOFT WOOD OR SUCKER GROWTH AND ALL BROKEN OR BADLY DAMAGED BRANCHES SHALL BE REMOVED WITH A CLEAN CUT. ALL
PRUNING TO BE PERFORMED BY CERTIFIED ARBORIST, IN ACCORDANCE WITH ANSI A-300.
14. SHRUBS AND GROUND COVER PLANTS SHALL BE EVENLY SPACED IN ACCORDANCE WITH THE DRAWINGS AND AS INDICATED ON THE PLANT LIST.
MATERIALS INSTALLED SHALL MEET MINIMUM SPECIMEN REQUIREMENTS OR QUANTITIES SHOW ON PLANS, WHICHEVER IS GREATER. CULTIVATE ALL PLANTING AREAS TO A MINIMUM DEPTH OF 6", REMOVE AND DISPOSE ALL DEBRIS. MIX TOP 4" THE PLANTING SOIL MIXTURE AS SPECIFIED IN
SECTION E. THOROUGHLY WATER ALL PLANTS AFTER INSTALLATION.
15. TREE GUYING AND BRACING SHALL BE INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH THE PLANS TO INSURE STABILITY AND MAINTAIN TREES IN AN UPRIGHT POSITION. IF THE CONTRACTOR AND OWNER DECIDE TO WAIVE THE TREE GUYING AND BRACING, THE OWNER SHALL NOTIFY THE PROJECT LANDSCAPE ARCHITECT IN WRITING AND AGREE TO INDEMNIFY AND HOLD HARMLESS THE PROJECT LANDSCAPE ARCHITECT IN THE EVENT UNSUPPORTED TREES PLANTED UNDER THIS CONTRACT FALL AND DAMAGE PERSON OR PROPERTY.
16. ALL PLANT BEDS SHALL BE KEPT FREE OF NOXIOUS WEEDS UNTIL FINAL ACCEPTANCE OF WORK. IF DIRECTED BY THE OWNER, "ROUND-UP" SHALL BE APPLIED FOR WEED CONTROL BY QUALIFIED PERSONNEL TO ALL PLANTING AREAS IN SPOT APPLICATIONS PER MANUFACTURER'S PRECAUTIONS AND SPECIFICATIONS. PRIOR TO FINAL INSPECTION, TREAT ALL PLANTING BEDS WITH AN APPROVED PRE-EMERGENT HERBICIDE AT AN APPLICATION RATE RECOMMENDED BY THE MANUFACTURER. (AS ALLOWED BY JURISDICTIONAL AUTHORITY)
P. LAWN SODDING
1. THE WORK CONSISTS OF LAWN BED PREPARATION, SOIL PREPARATION, AND SODDING COMPLETE, IN STRICT ACCORDANCE WITH THE SPECIFICATIONS AND THE APPLICABLE DRAWINGS TO PRODUCE A TURF GRASS LAWN ACCEPTABLE TO THE OWNER.
2. ALL AREAS THAT ARE TO BE SODDED SHALL BE CLEARED OF ANY ROUGH GRASS, WEEDS, AND DEBRIS BY MEANS OF A SOD CUTTER TO A DEPTH OF THREE (3) INCHES, AND THE GROUND BROUGHT TO AN EVEN GRADE. THE ENTIRE SURFACE SHALL BE ROLLED WITH A ROLLER WEIGHING NOT MORE THAN ONE-HUNDRED (100) POUNDS PER FOOT OF WIDTH. DURING THE ROLLING, ALL DEPRESSIONS CAUSED BY SETTLEMENT SHALL BE FILLED WITH ADDITIONAL SOIL, AND THE SURFACE SHALL BE REGRADED AND ROLLED UNTIL PRESENTING A SMOOTH AND EVEN FINISH TO THE
REQUIRED GRADE.
3. PREPARE LOOSE BED FOUR (4) INCHES DEEP. HAND RAKE UNTIL ALL BUMPS AND DEPRESSIONS ARE REMOVED. WET PREPARED AREA
THOROUGHLY.
4. SODDING
a. THE CONTRACTOR SHALL SOD ALL AREAS THAT ARE NOT PAVED OR PLANTED AS DESIGNATED ON THE DRAWINGS WITHIN THE CONTRACT
LIMITS, UNLESS SPECIFICALLY NOTED OTHERWISE.
b. THE SOD SHALL BE CERTIFIED TO MEET FLORIDA STATE PLANT BOARD SPECIFICATIONS, ABSOLUTELY TRUE TO VARIETAL TYPE, AND FREE FROM
WEEDS, FUNGUS, INSECTS AND DISEASE OF ANY KIND.
c. SOD PANELS SHALL BE LAID TIGHTLY TOGETHER SO AS TO MAKE A SOLID SODDED LAWN AREA. SOD SHALL BE LAID UNIFORMLY AGAINST THE EDGES OF ALL CURBS AND OTHER HARDSCAPE ELEMENTS, PAVED AND PLANTED AREAS. ADJACENT TO BUILDINGS, A 24 INCH STONE MULCH STRIP SHALL BE PROVIDED.