Code 15 OK-410(V)4 H&SG Sources Sought Addendum
Distribution Statement A: Approved for Public Release. Distribution Unlimited.
NUWC Division Newport January 2022
Code 15 OK-410(V)4 H&SG Included in this Addendum
General Requirements
General Layout
Winch Assembly
Levelwind
Overboarding Fairlead
Control Console and Operator Protection Screen
Maintenance Kit
Power Distribution Panel
Maximum Procurement Quantities
H&SG General Requirements
Winch, Levelwind, Fairlead
Survival Snag Load 84,000 lbs
Max Static Load 21,500 lbs
Dynamic Load 6400 – 12,900 lbs
Main and Emergency Drive Modes
Automatic and Manual Control Modes
Power Distribution Panel
Ship Power 440Vac, 3Φ, 60 Hz
Max Power ≤ 40 kWatts
Redundant Levelwind Servo Drives
Distribution Statement A: Approved for Public Release. Distribution Unlimited.
MFTA OK-410(V)4 H&SG
General DDG-51 FLT IIA Layout
Unit 8
Unit 7
Unit 1
Unit 2
Unit 3
Unit 4 Unit 9 Unit
Number Assembly
1 Winch Assembly
2 Levelwind Assembly
3 Overboarding Fairlead
4 Control Station Assembly
7 Operator Protection Screen
8 Maintenance Kit
9 Power Distribution Panel
OK-410(V)4 Winch
5Distribution Statement A: Approved for Public Release. Distribution Unlimited.
OK-410(V)4 Winch Assy
Winch Frame Assy Power Train Emergency Power Train Steel Structural Shapes/ Plating
Port Pedestal support hydraulic motor
Stbd Pedestal support drum bearing block and serves as hydraulic reservoir
Drum is rigid weldment with a hydraulically activated Pawl Brake and Band Brake that is spring set and hydraulically released, both attached to the frame.
Winch drum has self-aligning, spherical roller bearing.
Junction Box for all connections from the Control Console and E- Stop Switch.
40 HP Electric Motor
Hydraulic Pump, Suction Filter, Proportional Control Valve, Manifold, Motor and Pressure Gages
Heat Exchanger
Return Filter
E-Hand Pump to power band brake and pawl.
7.5 HP Electric Motor
Gear Reducer & Drive Sprocket
Bull Gear Sprocket and mechanical locking pins
OK-410(V)4 H&SG Levelwind
LW Support Frame LW Carriage
Proximity Sensor limits carriage over travel
Absolute Encoder tracks cable position
Mounted below Support Frame
Traverse on 2 RoundWay rollers
DC Servo Drive Motor (Port Side) connected to Speed Reducer and Ball Lead Screw
Cable Track routes Signal Connectors to Carriage Junction Box
Carriage Bell Mouth oriented toward Fairlead
Angle Sensor Assy senses cable departure angle as the Carriage transverse the Support Frame
Diameter Sense Roller Assy and Proximity Sensor senses tow cable and towed array diameter changes and provides secondary means for Array Imminent condition
OK-410(V)4 Overboarding Fairlead
OK-410(V)4 H&SG Overboarding Fairlead
Fairlead Plug Assy Wiper and Drain Assy Bell Mouth Monel
Casting
Watertight Door secures winch space when MFTA is stowed
Seals Fairlead against weather/sea when MFTA is deployed
Provides fresh water lubrication
Minimizes water intake into winch space during MFTA retrieval
OK-410(V)4 Control Console and Operator Protection Screen
10Distribution Statement A: Approved for Public Release. Distribution Unlimited.
OK-410(V)4 H&SG Control Console w/ Protection Screen
General Features
Provides standing operator primary control for system operation
Includes:
Upper Control/Lower
Control Panels (UCP/LCP) Low voltage power supplies Control Logic Circuits
(Programmable Automation Controller – PAC)
UCP
Pawl and Brake
Processor and Battleshort
Main Power Controls
2 Alphanumeric Digital Displays for:
Cable/System Status Performance Monitoring Fault
Detection/Localization
LCP
E-Stop and E-Drive Operation
Winch & LW Control Joysticks
Lamp Test
Winch Running Time Counter
OK-410(V)4 H&SG Operator Protection Screen
General Features Lexan (polycarbonate) sheet embedded inside a shock-mounted metal frame
Encloses Control Console on three sides
Protects operator from flying debris caused by either cable separation or winch malfunction.
OK-410(V)4 H&SG Maintenance Kit
General Features
Lockable, watertight container
Holds special tools:
Hydraulic Cable Wire Cutter Reservoir hand pump handle E-Drive Adapter Assy Angle Sense Adjustment Tool Ship Supplied Tools
OK-410(V)4 Power Distribution Panel
14Distribution Statement A: Approved for Public Release. Distribution Unlimited.
OK-410(V)4 H&SG Power Distribution Panel
General Features
Controls application of electrical power to the H&SG
Routes ship 440 VAC to circuit breakers for overload protection
From circuit breakers power is distributed to:
Control Console, Levelwind, winch main and emergency drive motors and hydraulic fluid heaters
Indicator lights show status of:
System power, power supplies, LW Servo Drives and fluid heaters
Power Interlock requires disconnection of power prior to opening Panel door.
System On Timer Counter
OK-410(V)4 Programmatic Items
Procurement quantities tied to fielding plan for
AN/SQQ-89A(V)15
External drivers such as changes to CNO availability schedule for ship installations and Congressional budget adjustments drive actual procurement quantities
Quantities identified represent maximum expected plan
Intent is to exercise yearly procurement during 2nd Qtr of each fiscal year
Distribution Statement A: Approved for Public Release. Distribution Unlimited.
Fiscal Year FY24 FY25 FY26 FY27 FY28 Total Program OK-410 HS&G Buy Plan (Maximum)
8 6 7 6 7 34
| Slide Number 1 |
| Code 15 OK-410(V)4 H&SG�Included in this Addendum |
| H&SG General Requirements |
| MFTA OK-410(V)4 H&SG�General DDG-51 FLT IIA Layout |
| Slide Number 5 |
| Slide Number 6 |
| OK-410(V)4 H&SG Levelwind |
| Slide Number 8 |
| OK-410(V)4 H&SG Overboarding Fairlead |
| Slide Number 10 |
| OK-410(V)4 H&SG Control Console�w/ Protection Screen |
| OK-410(V)4 H&SG Operator�Protection Screen |
| OK-410(V)4 H&SG Maintenance Kit |
| Slide Number 14 |
| OK-410(V)4 H&SG Power Distribution Panel |
| OK-410(V)4 Programmatic Items |
File details come from the government source that posted it. Updated .