OEV27007122 - Specifications.pdf

PDF 248 KB Posted

Attached to
MPA 595 OE Air Compressor Maintenance Repair and Installation
Solicitation number
OEV27007122
Issued by
Rhode Island

About this file

This is an Agency Solicitation Specifications document for the State of Rhode Island's MPA 595 Open Enrollment program seeking qualified vendors to provide air compressor maintenance, repair, and installation services statewide. The solicitation encompasses preventative maintenance services on large air compressors performed on varying schedules (twice annually, quarterly, or as required), including comprehensive data collection reporting, coolant analysis, filter and oil changes, equipment inspections, diagnostics, and on-call services. Services must be performed by fully trained, factory-authorized field technicians during normal business hours (Monday through Friday, 8:00 a.m. to 4:00 p.m.). The scope addresses rotary screw compressors, compressed air dryers, and accessories, with specific maintenance requirements based on equipment type and manufacturer recommendations. Vendors must provide three professional references demonstrating similar service experience, technician resumes, and relevant air compressor certifications. No specific response date, due date, site visit provisions, bidder's conference, or award date is identified in this document. The contract term and renewal options are not specified in the provided file.

Evaluation of vendor proposals occurs on a pass/fail basis across all criteria categories: references, resumes, certifications, and overall qualification. All criteria must receive a pass determination for inclusion on the qualified vendor list. Pricing is not evaluated at the vendor qualification stage; rather, individual state agencies will request competitive quotes from qualified vendors when services are needed, with pricing adjusted based on equipment type, size, manufacturer, location, and scope variations. The solicitation explicitly states that no costs other than parts and labor for work described are authorized, with out-of-pocket expenses such as travel, meals, mileage, and portal-to-portal charges prohibited. Technicians must have a minimum of three years' experience with this type of work and maintain proper work attire and work area cleanliness, with all debris removal and disposal costs the responsibility of the contractor.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2019-1 Page 1 of 5 Revised 04/02/2020

OEV – AGENCY SOLICITATION SPECIFICATIONS

TITLE: MPA 595 OE AIR COMPRESSOR MAINTENANCE, REPAIR &

INSTALLATION

SECTION A. BACKGROUND

MPA 595 Open Enrollment seeks qualified vendors with the capabilities to supply air compressor maintenance, repair and installation as described herein.

The scope provided is a generalization that will encompass air compressor maintenance, repair and installation state-wide. Agencies throughout the State will contact vendors placed on the qualified list to provide quotes including but not limited to installation of new compressors, changing out filters, oil, belts, on-call services, quarterly, annually, biannual maintenance, repairs, purchases of parts, and all other general maintenance needs.

Vendors will have the ability to inspect equipment and location prior to submitting a quote. User agencies will conduct min-bids from the qualified list in order to determinate lowest price offer. It is understood that prices will vary due to equipment type, size, manufacture and location. For these reasons and other unknown factors the State is seeking vendor qualifications only that will be evaluated for placement on Master Price Agreement contract. At time of actual services needed vendor will then provide pricing to the agency request.

SECTION B: SCOPE OF WORK AND REQUIREMENTS

This procurement is for the provision of preventative maintenance services on large air compressors to be performed twice annually, quarterly or as required, including but not limited to:

• Comprehensive Data Collection Report that uses data point to record, compare, verify, and show trends where applicable.

• Services must be conducted by fully trained and factory authorized Field Technicians.

• Coolant Analysis by industry leading lubricant experts.

• Data review and recommendations from the vendor’s technicians when analysis identifies items that need to be addressed.

2019-1 Page 2 of 5 Revised 04/02/2020

• Periodic Face to Face meeting with agency staff representative to review planned and preventative maintenance, diagnostic reports and discuss any recommended actions.

Service Requirements

1. Rotary Screw Compressor :

Change air & oil filter per Operator’s Manual recommendation Change separator element per Operator’s Manual recommendation Change Coolant per coolant analysis recommendation Check cooler condition and blow out as needed (power washing not included) Check and clean condensate drain’s as needed

Check condition of belts, adjust tension, and/or change as needed Lubricate main drive motor and cooling fan motor as needed Complete a multipoint inspection and document Control Panel Parameter per visit Review warning shutdown history for any abnormal shutdowns per visit All parts& lubricants will be disposed in accordance with local, state, and federal OSHA/EPA Rebuild compressor inlet valve every 16,000 hrs. (oil free fixed speed rotary units only) Rebuild compressor discharge check valve every 8,000 hrs. (oil free units only) Rebuild blow down valve every 8,000 hrs. (oil free fixed speed rotary units only)

Compressed Air Dryer Perform a multipoint inspection per visit Check and clean condensate drains as needed Check condenser coil condition and blow out as needed (power washing not included) Replace dryer panel filter as needed (refrigerated dryers only) Inspect Desiccant Dryer per visit (Desiccant changes quotes as additional service) Replace Desiccant Dryer mufflers annually (Desiccant Dryers only)

Accessories:

Annual replacement of inline filter elements Annual replacement of oil water separator adsorption modules

Inspection & Diagnostics

Inspection Data Inspection Summary Report: complete Comprehensive report on site by an Certified Technician; record Operational Readings, 22 Visual Checks, Air/Oil/Water safety alarms and shutdown levels; provide analysis and report generation from collected data in order to provide vital trending details; this report

2019-1 Page 3 of 5 Revised 04/02/2020 should provide a full health summary and include recommendations for additional services if required.

Shock Pulse Monitoring: monitor the shock pulse of the drive train of the rotary Compressor; analyze collected data and compare to original equipment specifications; Electronically archive service history data base for future comparative analysis to Subsequent readings; review concerning levels for recommended actions.

Fluid Analysis Report: analyze coolant and rate from “Normal” to “Critical Condition”

With an associated color code (Green to Red); test coolant for wear metals, Contaminates and additive metals; provide fluid properties including viscosity, acid Number, oxidation, and water content; provide details as to the oil change date, filter Change date, and any recommendations.

Shock Pulse Monitoring/Monitor the shock pulse of the drive train of the rotary Compressor:

Analyze collected data and compare to original equipment specifications;

Electronically archive service history data base for future comparative analysis to Subsequent readings; review concerning levels for recommended actions.

Fluid Analysis Report:

Analyze coolant and rate from “Normal to “Critical Condition” With an associated color code (Green to Red); test coolant for wear metals, Contaminates and additive metals; provide fluid properties including viscosity, acid Number, oxidation, and water content; provide details as to the oil change date, filter Change date, and any recommendations.

The Agreement should provide planned maintenance for Air Compressor Systems. It should also assure that factory recommended services are provided on intervals consistent with the manufacturer’s recommendations.

Service visits with associated labor, all necessary consumable parts, lubricants, filters, etc., Must be consistent with the manufacturer’s recommendations based on hours of operation as set forth on the Scope of Service page above. Vendor shall perform the necessary Services during normal business hours Monday through Friday, from 8:00am – 4:00pm

Personnel Requirements

• Technicians must have a minimum of three (3) years of experience with this type of project

• Proper work attire will be maintained by contractor’s employees.

• Contractor shall clean trash, debris, and sweep work area daily.

• All debris removal and cost of disposal shall be the responsibility of the contractor.

2019-1 Page 4 of 5 Revised 04/02/2020

Experience & Qualifications

• Respondents must provide three (3) references of similar scopes of services currently or recently performed as in this proposal. References must include the name of the company/entity, length of service, contact person, and present address and phone number. References may be checked prior to recommendation.

• Resumes must be provided for the technicians that will be assigned to this project.

• Submit certifications held for services for various types of air-compressors.

Change or Addition to Scope of Services

The State without invalidating the Master Contract, may make changes by altering, adding to, or deduction from the Scope of Services at any time during the term of the contract in order to meet current needs.

Individual Contract Agreement pricing offered to each individual agency shall be adjusted accordingly, upon mutual agreement between State Agency and Contractor.

Should the State Agency request additional services during the term of the Contract Agreement an amendment to provide these services at the same price as quoted will be understood as included in the Respondent’s submission.

Example of Equipment List:

Sullair MOD NO. 1800 SERIAL NO. 201410210011 Devair MOD NO. WATC-5000 SERIAL NO. 35274 LI

MOD NO. WATC-5000 SERIAL NO. 35275 LI

Devair MOD TASV – 5052 SERIAL NO. 42573 OG MTA-Ditech dryer unit for the compressors (Dryer C Ditech 0100 model)

2019-1 Page 5 of 5 Revised 04/02/2020

1. Proposal - Vendor Qualification Assessment

Narrative and format: Vendor responses must address specifically each of the following elements:

A. A vendor assessment form will be provided. It is permissible to use additional sheets if needed. In addition submit as separate attachments the following evaluation information with proposal.

SECTION D: EVALUATION AND SELECTION - SOLICITATION SPECIFIC

Proposals shall be reviewed by the Division of Purchases on a “Pass/Fail” basis. All criteria must receive a “Pass” determination for a vendor’s potential inclusion on the resulting OE MPA’s qualified vendor list. Any criteria with a “Fail” determination will not be reviewed further and the vendor will be dropped from consideration.

Proposals shall be reviewed and scored based upon the following criteria:

Criteria

Pass/Fail

References Pass/Fail

Resume Pass/Fail

Certifications Pass/Fail

Overall Pass/Fail Pass/Fail

NOTE: See the “Requirements” tab of this solicitation for additional information on the evaluation and selection process in the “OE Standard Specifications- Vendor Qualification Assessment” section.

SECTION A. BACKGROUND
SECTION B: SCOPE OF WORK AND REQUIREMENTS
1. Proposal - Vendor Qualification Assessment

SECTION D: EVALUATION AND SELECTION - SOLICITATION SPECIFIC