OEH-8 Proposed Chase.pdf
PDF 496 KB Posted
- Solicitation number
- IHS1507039
About this file
The document is a detailed site plan for a water and sewer service installation project for the Indian Health Service located at the Rikki Chase property in Miami, Oklahoma. The plan specifies installing a 700-gallon capacity aerobic pump tank with a spray area of 6,038 sq ft, along with 275 linear feet of 1 1/2" HDPE DR11 water service line. Technical specifications include installing concrete collars around spray heads, avoiding existing underground utilities, maintaining ODEQ standards, and connecting the system to an installed disconnect box. The water service line will be installed from the existing water meter to the home stub out, with requirements to maintain specific offsets from spray effluent and between water and sewer lines.
The project is part of a federal solicitation (IHS1507039) issued by the Indian Health Service, set aside for 100% Indian Owned businesses under NAICS code 237110. The solicitation has an estimated price range under $25,000, with a 60-calendar day performance period. Key submission requirements include a firm fixed-price quote, technical specifications, two relevant past performance examples, and an Indian Economic Enterprise Representation Form. Quote submissions are due by March 31, 2024, with questions accepted until March 24, 2024. Award will be made to the lowest-priced, technically acceptable offer meeting all specifications.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
© 2024 Microsoft Corporation © 2024 Maxar ©CNES (2024) Distribution Airbus DS
M W W W W W W W W W W W W W W W W W
W
SL
W
SL
W
SL
W
SL
W
SL
W
SL
W
SL
W
SL
W
SL
W
SL
W
SL
IN
D
I A N
HEA LTH SER
V
ICE
1 9 5 5
INSTALL TWO-WAY CLEANOUT
EAST 80 RD
RIKKI CHASE HOME
PROPERTY LINE
INSTALLED FACILITIES
Sewer
· 700 gallon capacity Aerobic
Pump Tank
· Required Spray: 5,840 sq ft
· Actual Spray: 6,038 sq ft
· Install concrete collars around spray heads per BPA specifications
· Avoid existing underground utilities
· ·Maintain offsets per ODEQ standards
· Connect System to Installed Disconnect Box.
Water
· 275 LF of 1 1/2 " HDPE
DR11 Water Service Line
· Install Water Service Line from existing meter to the home stub out
· Avoid existing underground utilities
· Maintain 25' offset from Spray Effluent.
· Maintain 2' vertical offset between water and sewer
PROPOSED 700 GALLON CAPACITY PUMP TANK
DIRT ROAD TO
PROPERTY
MAKE CONNECTION TO DISCONNECT BOX
WATER METER
PROPOSED 275' OF WSL
WATER MAIN
SPRAY HEADS, R=31'
EMPTY TRAILER
AutoCAD SHX Text
INDIAN HEALTH SERVICE
AutoCAD SHX Text
OKLAHOMA CITY AREA
AutoCAD SHX Text
MIAMI OEH&E
AutoCAD SHX Text
SANITATION FACILITIES CONSTRUCTION
AutoCAD SHX Text
LAYOUT NAME:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
FILE NAME:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJ ENG:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
RIKKI, CHASE SR# 1192
AutoCAD SHX Text
OEH-8 PROPOSED
AutoCAD SHX Text
(918) 542-6414
AutoCAD SHX Text Miami, Oklahoma 74354
AutoCAD SHX Text 21 N Eight Tribes Trail
AutoCAD SHX Text Steven Boyd
AutoCAD SHX Text S Boyd
AutoCAD SHX Text R Anderson
AutoCAD SHX Text 1"=50'
AutoCAD SHX Text 10/23/24
AutoCAD SHX Text Ottawa County, OKLAHOMA
AutoCAD SHX Text Miami, OK 74354
AutoCAD SHX Text 62235 E. 80 Road
AutoCAD SHX Text CHASE, RIKKI #1192/Project# OK 21-W60
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets and Views |
| 8.5x11 Portrait |
File details come from the government source that posted it. Updated .