OCS DRAHNER SCS FLOOR PLANS.pdf

PDF 2 MB Posted

Attached to
Oxford Schools Drahner Rd. building structured cabling
Solicitation number
RFP - OXFO - 240000000577
Issued by
Oakland County, Onekama Village, Michigan

About this file

The document provided is a set of floor plans related to the Oxford Schools Drahner Rd. building structured cabling contract opportunity in the state of Michigan, specifically within the jurisdictions of Oakland County and Onekama Village. The plans detail the communications cabling layout, including the placement of data outlets, WAP locations, and other infrastructure. The contract involves the installation of the structured cabling system for this facility. The bidding deadline is 12/5/2023, with an owner review scheduled for 11/20/2023. The contract term and any potential renewal options are not specified in the provided information.

The pricing terms, set asides, incumbents, funding requirements, and other salient financial details are not included in the document. The document focuses on the technical specifications and layout of the communications cabling infrastructure for the Oxford Schools Drahner Rd. building.

View the file

Other files

File Type Posted
OCS Drahner Cable RFP.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

S

S

S

S

S

S

S

G

T X

WVUQPML

COMMERCIAL

LAUNDRY

B003

DRYER

EXH.

ROOM

B019

B002

ELEVATOR

EQUIP.

STAIR

A0

CLEAN

LINEN

B004

OFFICE

B006

B001

CORRIDOR

B018

MECHANICAL/

ELECTRICAL

LAUNDRY

B015

B016A

RESTROOM

RESTROOM

B016

JAN

B017

B009A

CLASSROOM

B014

CLASSROOM

STORAGE

B012

STORAGE

B010

STORAGE

B011

STAIR

B0

B001

CORRIDOR

LPA

LPEA

EMDPTRANSFER SWITCH

MSBD

B009B

SENSORY

AREA

B007

CLASSROOM

LPA-27

(R)

(R)

(R)

(R)

(R)

DP- 1

ELEVATOR

STORAGE

B013

STORAGE

B009

(R)

(R)

ALUMINUM POWER

POLE WITH (4) DUPLEX

RECEPTACLES AND

(4) DATA OUTLETS

CR

CR

MDF

0' 5' 10' 20' 30' 40' 50'

NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS

WAP

2D

1D

2D

2D

1D FUTURE SPKR

2D

2D

1D FUTURE SPKR

2D

1D WAP

4D4D

1D WAP

BASEMENT

FLOOR BOX - DATA, QTY

AS SHOWN

CEILING (WAP) DATA OUTLET -

TERMINATE IN SURFACE BOX

OUTLET - DATA, QTY AS

SHOWN

INSTALL COMMS CABINET,

CABINET BY OTHERS

COMMUNICATIONS

SYMBOLS

WALL PHONE (1) DATA

CEILING (CAMERA) DATA OUTLET

TERMINATE IN SURFACE BOX

12/5/2023 BIDDING EGH

11/20/2023 OWNER REVIEW EGH

DATE ISSUE AUTHOR

OCS DRAHNER

FACILITY

COMMUNICATIONS CABLING

T-100

C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473

Phone: 810.720.3820 www.ctpartners.net

T E C H N O L O G Y P A R T N E R S

TECHNOLOGY DESIGN I CONSULTING I PLANNING

KEYPLAN

LV CABLING NOTES

1. CABINETS PROVIDED BY OWNER, INSTALLATION BY

CONTRACTOR. PROPERLY FASTEN TO FLOOR, GROUND

AND BOND. PROVIDE CABLE SUPPORT TO CABINET WHEN

NOT ADJACENT TO WALL.

2. FIRE-STOP ALL PENETRATIONS TO MATCH FIRE RATING OF

PENETRATED PARTITION.

3. GROUND ONE END ONLY OF ARMORED FIBER OPTIC CABLE.

4. PROVIDE 10' SERVICE LOOP IN ALL CABLES TERMINATED IN

MDF OR IDFS. NEATLY COIL AND FASTEN TO STRUCTURE

ALL SERVICE LOOPS.

5. TERMINATE ALL UTP CABLE AT WAO ENDS WITH 8P/8C

(RJ45) JACKS IN FACEPLATES OR SURFACE HOUSINGS

WHEN IN CEILINGS - FASTEN SURFACE BOXES TO

STRUCTURE.

6. PROVIDE SUFFICIENT SERVICE LOOP IN UTP SPEAKER

CABLE TO ALLOW PLACEMENT OF SPEAKERS ANYWHERE

IN ROOM.

7. SPEAKERS AND WAPS BY OTHERS

8. PROVIDE 5M OF SERVICE LOOP AT EACH WAP OUTLET

LOCATION IN CEILINGS.

9. NEATLY COIL AND FASTEN TO STRUCTURE ALL WAO

SERVICE LOOPS IN CEILINGS AT OUTLET.

10. COORDINATE ALL CABLE PULLS, PENETRATIONS AND

OUTLET LOCATIONS WITH OTHER TRADES AND OWNER.

S

S

S

S

S

S

S

S

T X Y Z

H I J N O S

MATCH LINE

E3.1A E3.1B

MATCH LINE

E3.1A E3.1B

COMMUNITY

ROOM

STORAGE

STORAGE

STORAGE

STORAGE

STAIR

A1

RECEIVING/

LOADING

DOCK

CIRCULATION

PARENT

ROOM

KITCH.

STOR.

DISH

WASHING

CAFETERIA

KITCHEN

CAFETERIA

CHAIR

STORAGE

STAIR

D1

PPK

LPEDLPD

JAN.

SOUND

SYSTEM

(R)

(R)

(R)

(R)

MIC

(R)

(R)

(R)

(R)

(R)

(R)

SOUND

RACK

EXISTING

GENERATOR

EXISTING

DTE TRANSFORMER

PPK1

K

GARAGE

(R)

48" AFF

48" AFF

0' 5' 10' 20' 30' 40' 50'

NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS

1D WAP

1D WAP

1D WAP

1D FUTURE SPKR

1D

1D

W

W

FOR EXTERIOR

CAMERA

EXTERIOR

FOR CAMERA

FOR EXTERIOR

CAMERA

UNIT A

UNIT B

FLOOR BOX - DATA, QTY

AS SHOWN

CEILING (WAP) DATA OUTLET -

TERMINATE IN SURFACE BOX

OUTLET - DATA, QTY AS

SHOWN

INSTALL COMMS CABINET,

CABINET BY OTHERS

COMMUNICATIONS

SYMBOLS

WALL PHONE (1) DATA

CEILING (CAMERA) DATA OUTLET

TERMINATE IN SURFACE BOX

12/5/2023 BIDDING EGH

11/20/2023 OWNER REVIEW EGH

DATE ISSUE AUTHOR

C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473

Phone: 810.720.3820 www.ctpartners.net

T E C H N O L O G Y P A R T N E R S

TECHNOLOGY DESIGN I CONSULTING I PLANNING

OCS DRAHNER

FACILITY

COMMUNICATIONS CABLING

T-101A

KEYPLAN

LV CABLING NOTES

1. CABINETS PROVIDED BY OWNER, INSTALLATION BY

CONTRACTOR. PROPERLY FASTEN TO FLOOR, GROUND

AND BOND. PROVIDE CABLE SUPPORT TO CABINET WHEN

NOT ADJACENT TO WALL.

2. FIRE-STOP ALL PENETRATIONS TO MATCH FIRE RATING OF

PENETRATED PARTITION.

3. GROUND ONE END ONLY OF ARMORED FIBER OPTIC CABLE.

4. PROVIDE 10' SERVICE LOOP IN ALL CABLES TERMINATED IN

MDF OR IDFS. NEATLY COIL AND FASTEN TO STRUCTURE

ALL SERVICE LOOPS.

5. TERMINATE ALL UTP CABLE AT WAO ENDS WITH 8P/8C

(RJ45) JACKS IN FACEPLATES OR SURFACE HOUSINGS

WHEN IN CEILINGS - FASTEN SURFACE BOXES TO

STRUCTURE.

6. PROVIDE SUFFICIENT SERVICE LOOP IN UTP SPEAKER

CABLE TO ALLOW PLACEMENT OF SPEAKERS ANYWHERE

IN ROOM.

7. SPEAKERS AND WAPS BY OTHERS

8. PROVIDE 5M OF SERVICE LOOP AT EACH WAP OUTLET

LOCATION IN CEILINGS.

9. NEATLY COIL AND FASTEN TO STRUCTURE ALL WAO

SERVICE LOOPS IN CEILINGS AT OUTLET.

VC

C C

S

S

S

S

C

C

S

S

S

S

S

S

S

S

S

S

A B B1 D E G T X

WVUQPML

N O

MATCH LINE

E3.1A E3.1B

MATCH LINE

E3.1A E3.1B

STAIR

C1

OFFICE

130A

IDF

CORRIDOR

100C

OFFICE

130B

OFFICE

130C

OFFICE

130A

OFFICE

126A

OFFICE

126B

126C

MEETING

ROOM

126D

STORAGE

LOUNGE/

WORKROOM

CLASSROOM

MEETING

ROOM

112A

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

MAIL

SECURITY

LOBBY

VESTIBULE

STAFF

TOILET

STAFF

TOILET

BOYS

133A

CIRCULATION

GIRLS

131A

CORRIDOR

100B

STUDENT

LOUNGE

OFFICE

OFFICE

117ASTAIR

B1

LPEC

LPC

117B

FILE

ROOM

WORKROOM

STORAGE

112B

OFFICE

125A

125B

SENSORY

ROOM /

SPECIAL

EDUCATION

CONDUIT

UP

IDF

RACK

RELOCATED

LPB

CR

ELEC.

132CR

CR

(R)

(R)

(R)

(R)

(R)

(R)

(R) (R)

OFFICE

130D

(R)

UNI.

RESTROOM

133B

UNI.

TOILET

131B

(R)

LPB-12

LPB-16

IRRIGATION

CONTROLLER

LPC-14

CR

JANITOR

CR

CR

FACP

INTERCOM

0' 5' 10' 20' 30' 40' 50'

NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS

1D FUTURE SPKR

1D WAP

1D FUTURE SPKR

1D WAP

1D WAP

1D WAP

2D

2D

2D

2D

2D

2D 2D

2D

2D

2D

1D 2D

2D 2D

2D

2D

1D

2D

2D

1D

1D

2D

1D FUTURE SPKR

1D FUTURE SPKR

1D FUTURE SPKR

1D

1D FUTURE SPKR 1D FUTURE SPKR

2D 2D

1D 1D

2D

2D 2D

2D

2D

1D FUTURE SPKR

4D

48" AFF

W

EXTERIOR

FOR CAMERA

EXTERIOR

FOR CAMERA

FOR EXTERIOR

CAMERA

UNIT A

UNIT B

FLOOR BOX - DATA, QTY

AS SHOWN

CEILING (WAP) DATA OUTLET -

TERMINATE IN SURFACE BOX

OUTLET - DATA, QTY AS

SHOWN

INSTALL COMMS CABINET,

CABINET BY OTHERS

COMMUNICATIONS

SYMBOLS

WALL PHONE (1) DATA

CEILING (CAMERA) DATA OUTLET

TERMINATE IN SURFACE BOX

T-101B

12/5/2023 BIDDING EGH

11/20/2023 OWNER REVIEW EGH

DATE ISSUE AUTHOR

C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473

Phone: 810.720.3820 www.ctpartners.net

T E C H N O L O G Y P A R T N E R S

TECHNOLOGY DESIGN I CONSULTING I PLANNING

OCS DRAHNER

FACILITY

COMMUNICATIONS CABLING

KEYPLAN

LV CABLING NOTES

1. CABINETS PROVIDED BY OWNER, INSTALLATION BY

CONTRACTOR. PROPERLY FASTEN TO FLOOR, GROUND

AND BOND. PROVIDE CABLE SUPPORT TO CABINET WHEN

NOT ADJACENT TO WALL.

2. FIRE-STOP ALL PENETRATIONS TO MATCH FIRE RATING OF

PENETRATED PARTITION.

3. GROUND ONE END ONLY OF ARMORED FIBER OPTIC CABLE.

4. PROVIDE 10' SERVICE LOOP IN ALL CABLES TERMINATED IN

MDF OR IDFS. NEATLY COIL AND FASTEN TO STRUCTURE

ALL SERVICE LOOPS.

5. TERMINATE ALL UTP CABLE AT WAO ENDS WITH 8P/8C

(RJ45) JACKS IN FACEPLATES OR SURFACE HOUSINGS

WHEN IN CEILINGS - FASTEN SURFACE BOXES TO

STRUCTURE.

6. PROVIDE SUFFICIENT SERVICE LOOP IN UTP SPEAKER

CABLE TO ALLOW PLACEMENT OF SPEAKERS ANYWHERE

IN ROOM.

7. SPEAKERS AND WAPS BY OTHERS

8. PROVIDE 5M OF SERVICE LOOP AT EACH WAP OUTLET

LOCATION IN CEILINGS.

9. NEATLY COIL AND FASTEN TO STRUCTURE ALL WAO

SERVICE LOOPS IN CEILINGS AT OUTLET.

S

S

S

S

S

S

S

T X Y Z

H I J N O S

MEETING

ROOM

IDF

STAIR

D2

OFFICE

217A

OFFICE

216A

DATA

DEN

216B

OFFICE

217B

OFFICE

217DOFFICE

216C

OFFICE

217E

STAFF

TOILET

217H

MEETING

ROOM

216D

STAIR

A2

MATCH LINE

E3.2A E3.2B

MATCH LINE

E3.2A E3.2B

217G

UNI. TOILET

217C

OFFICE

(R)

(R)

(R)

(R)

CR

CR

STORAGE

MECHANICAL

HALL

STORAGE

CORRIDOR

201D

IDF

RACK

4" CONDUIT

SLEEVE

PT1

PT1

PT1

LPH- 17

STORAGE

205A

201A

CENTRAL

CORRIDOR

CR

0' 5' 10' 20' 30' 40' 50'

NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS

2D

2D 2D 2D 2D

2D 2D

2D 2D

2D 2D

2D

2D

2D

2D

2D

2D

2D

2D

2D 2D

1D

2D

2D

2D

UNIT A

UNIT B

FLOOR BOX - DATA, QTY

AS SHOWN

CEILING (WAP) DATA OUTLET -

TERMINATE IN SURFACE BOX

OUTLET - DATA, QTY AS

SHOWN

INSTALL COMMS CABINET,

CABINET BY OTHERS

COMMUNICATIONS

SYMBOLS

WALL PHONE (1) DATA

CEILING (CAMERA) DATA OUTLET

TERMINATE IN SURFACE BOX

T-102A

12/5/2023 BIDDING EGH

11/20/2023 OWNER REVIEW EGH

DATE ISSUE AUTHOR

C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473

Phone: 810.720.3820 www.ctpartners.net

T E C H N O L O G Y P A R T N E R S

TECHNOLOGY DESIGN I CONSULTING I PLANNING

OCS DRAHNER

FACILITY

COMMUNICATIONS CABLING

KEYPLAN

LV CABLING NOTES

1. CABINETS PROVIDED BY OWNER, INSTALLATION BY

CONTRACTOR. PROPERLY FASTEN TO FLOOR, GROUND

AND BOND. PROVIDE CABLE SUPPORT TO CABINET WHEN

NOT ADJACENT TO WALL.

2. FIRE-STOP ALL PENETRATIONS TO MATCH FIRE RATING OF

PENETRATED PARTITION.

3. GROUND ONE END ONLY OF ARMORED FIBER OPTIC CABLE.

4. PROVIDE 10' SERVICE LOOP IN ALL CABLES TERMINATED IN

MDF OR IDFS. NEATLY COIL AND FASTEN TO STRUCTURE

ALL SERVICE LOOPS.

5. TERMINATE ALL UTP CABLE AT WAO ENDS WITH 8P/8C

(RJ45) JACKS IN FACEPLATES OR SURFACE HOUSINGS

WHEN IN CEILINGS - FASTEN SURFACE BOXES TO

STRUCTURE.

6. PROVIDE SUFFICIENT SERVICE LOOP IN UTP SPEAKER

CABLE TO ALLOW PLACEMENT OF SPEAKERS ANYWHERE

IN ROOM.

7. SPEAKERS AND WAPS BY OTHERS

8. PROVIDE 5M OF SERVICE LOOP AT EACH WAP OUTLET

LOCATION IN CEILINGS.

9. NEATLY COIL AND FASTEN TO STRUCTURE ALL WAO

SERVICE LOOPS IN CEILINGS AT OUTLET.

S

S

S

S S S

S

S

S

S

S

S

S

S

S

S

A B B1 D E G T X

WVUQPML

N O

MATCH LINE

E3.2A E3.2B

MATCH LINE

E3.2A E3.1B

201A

CENTRAL

CORRIDOR

HIGH

SCHOOL

CLASSROOM

MIDDLE

SCHOOL

CLASSROOM

OFFICE

OFFICE

209A

MEETING

207A

OFFICE

207B

OFFICE

209B

OFFICE

209D

OFFICE

207D

OFFICE

207C

OFFICE

209C

HALLWAY

201B

OFFICE

207F

OFFICE

209F

STAIR

B2

LOUNGE/

WORKROOM

IDF

OFFICE

209E

OFFICE

207E

210F

SENSORY

ROOM /

SPECIAL

EDUCATION

ELEC.

BOYS

OFFICE

211E

OFFICE

211D

OFFICE

210D

OFFICE

210E

OFFICE

210C

OFFICE

210B

OFFICE

210A

IDF

STAIR

C2

OFFICE

211A

LOUNGE/

WORKROOM

OFFICE

211B

OFFICE

211C

JANITOR

LPEG

LPG

LPH

(RELOCATED)

LPF

(RELOCATED)

RELOCATED

EAGLE SECURITY

PANEL

(R)

(R)

(R)

CR

(R)

CR

CR

CR

(R)(R)(R)

CORRIDOR

201C

4" SLEEVE

IDF

RACK

4" SLEEVE

IDF

RACK

CR

CR

CR

0' 5' 10' 20' 30' 40' 50'

NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

1D WAP 1D WAP

1D FUTURE SPKR

2D FUTURE SPKR

1D FUTURE SPKR

1D 2D

1D

2D

1D WAP

1D WAP

1D WAP

1D FUTURE SPKR

2D

1D2D

2D

2D

2D

2D

2D 2D

2D 2D

2D 2D 2D 2D

2D 2D2D 2D

2D2D 2D 2D

W

48" AFF

2D

UNIT A

UNIT B

FLOOR BOX - DATA, QTY

AS SHOWN

CEILING (WAP) DATA OUTLET -

TERMINATE IN SURFACE BOX

OUTLET - DATA, QTY AS

SHOWN

INSTALL COMMS CABINET,

CABINET BY OTHERS

COMMUNICATIONS

SYMBOLS

WALL PHONE (1) DATA

CEILING (CAMERA) DATA OUTLET

TERMINATE IN SURFACE BOX

T-102B

12/5/2023 BIDDING EGH

11/20/2023 OWNER REVIEW EGH

DATE ISSUE AUTHOR

C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473

Phone: 810.720.3820 www.ctpartners.net

T E C H N O L O G Y P A R T N E R S

TECHNOLOGY DESIGN I CONSULTING I PLANNING

OCS DRAHNER

FACILITY

COMMUNICATIONS CABLING

KEYPLAN

LV CABLING NOTES

1. CABINETS PROVIDED BY OWNER, INSTALLATION BY

CONTRACTOR. PROPERLY FASTEN TO FLOOR, GROUND

AND BOND. PROVIDE CABLE SUPPORT TO CABINET WHEN

NOT ADJACENT TO WALL.

2. FIRE-STOP ALL PENETRATIONS TO MATCH FIRE RATING OF

PENETRATED PARTITION.

3. GROUND ONE END ONLY OF ARMORED FIBER OPTIC CABLE.

4. PROVIDE 10' SERVICE LOOP IN ALL CABLES TERMINATED IN

MDF OR IDFS. NEATLY COIL AND FASTEN TO STRUCTURE

ALL SERVICE LOOPS.

5. TERMINATE ALL UTP CABLE AT WAO ENDS WITH 8P/8C

(RJ45) JACKS IN FACEPLATES OR SURFACE HOUSINGS

WHEN IN CEILINGS - FASTEN SURFACE BOXES TO

STRUCTURE.

6. PROVIDE SUFFICIENT SERVICE LOOP IN UTP SPEAKER

CABLE TO ALLOW PLACEMENT OF SPEAKERS ANYWHERE

IN ROOM.

7. SPEAKERS AND WAPS BY OTHERS

8. PROVIDE 5M OF SERVICE LOOP AT EACH WAP OUTLET

LOCATION IN CEILINGS.

9. NEATLY COIL AND FASTEN TO STRUCTURE ALL WAO

SERVICE LOOPS IN CEILINGS AT OUTLET.

Sheets and Views
OCS DRAHNER SCS 11-21-23-BASEMENT
Sheets and Views
OCS DRAHNER SCS 11-21-23-1ST FLOOR A
Sheets and Views
OCS DRAHNER SCS 11-21-23-1ST FLOOR B
Sheets and Views
OCS DRAHNER SCS 11-21-23-2ND FLOOR A
Sheets and Views
OCS DRAHNER SCS 11-21-23-2ND FLOOR B

File details come from the government source that posted it. Updated .