REVISED ATTACHMENT F LOG.pdf

PDF 155 KB Posted

Attached to
NOAA All Hazards Weather Radio Maintenance-Revised
Solicitation number
NWWR4000-20-00092
Issued by

About this file

This document contains a request for information for maintenance services for National Oceanic and Atmospheric Administration All Hazards Weather Radio transmitter sites in Colorado. The anticipated contract would be for a one-year base period and four additional one-year option periods, for a total of five years. Services may include emergency corrective actions, regularly scheduled preventative maintenance, and maintenance logging.

Capability statements are requested to assess contractor experience and qualifications. Statements should be no more than ten pages and address the organization name and contact details, experience completing similar work with past contract details, ability to meet the performance work statement requirements including security clearances and experience with specific transmitter manufacturers. The capability statement will be considered to determine whether a forthcoming request for quotes will be set aside for small businesses or conducted through full and open competition or as a sole-source procurement.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT F

MAINTENANCE

Table 4-4, Maintenance Log Comment Sheet

SR-416 SERIAL # ________________________

SITE # _______________ CITY __________________________

NWS MAINTENANCE LOG COMMENT SHEET

DATE CORRECTIVE ACTION AND/OR NOTES

SR-416 SERIAL # ________________ P OR S Table 4-3, Maintenance Logging Chart NWS MAINTENANCE DATA LOG (Record corrective action and/or notes on comment sheet.)

SITE # _________________ CITY ______________________________________

TEST/ACTION STE

P

UNITS COND. DATE DATE DATE DATE DATE DATE

CORRECTIVE ACTION 1 yes or no

CLEAN AIR FILTERS 2 √

VISUAL INSPECTION 3 √OK

CHECK LAMPS 4 √OK

PA FORWARD POWER 5a W Into 50a

PA REFLECTED POWER 5a W Into 50a ANT. PA FORWARD PWR 5d W Into ant.

ANT. PA REFLECTED PWR 5d W Into ant.

EXCITER PWR PA BYPASS 5b W Into 50a POWER LEVEL RESET? 5c yes or no

EXC. FWD. PWR./DRIVE 6 W

EXC. REFLECTED PWR 6 W

TUBE REPLACED 6 yes or no

ELAPSED TIME 6a hrs.

EXC. DRIVER I 7 A

EXC. P.A. I 7 A

EXC. CONT. V 7 V

EXC. SUPP V 7 V

P.A. GRID I 7 mA

P.A. PLATE I 7 A

FREQUENCY ERROR 8 Hz

RESET TO FREQUENCY? 8 yes or no MODULATION DEV. 9 +kHz

AUDIO QUALITY 9 √OK

UNKEYED LINE VOLTAGE 10 Vac KEYED LINE VOLTAGE 10 Vac

PHONE LINE AUDIO 11 Vrms

INITIAL COL. COMPLETED √

File details come from the government source that posted it. Updated .