NOAA Standard Specification 0002.0.docx.pdf

PDF 79 KB Posted

Attached to
FY27 NOAA Ship Gordon Gunter Drydock REFERENCES Federal contract opportunity
Solicitation number
1305M226Q0144REF
Issued by
Department of Commerce National Oceanic and Atmospheric Administration

About this file

This is a NOAA Standard Specification document defining temporary services requirements for contract work performed on NOAA vessels at contractor facilities.

The specification establishes comprehensive requirements for supporting NOAA vessels during their time at a contractor's facility. All temporary services must be provided within two hours of ship arrival, with restoration of services within one hour after interruptions. Access requirements include two OSHA-compliant gangways (one forward and one aft) with appropriate lighting, fendering to prevent hull damage, and ice/snow removal without salt-based deicers. Utility services encompass uncontaminated potable water via new hoses (with Safe Drinking Water Act compliance verification), clean regulated electrical power per ANSI and IEEE standards, sanitary and cooling water supplies, pressure-tested fire water with hose trees and independent backup power, and steam supply (if required by the Contracting Officer Representative). Environmental services include sewage and turbid water disposal, garbage and recycling container provision with daily cleaning, and fire alarm system installation per NFPA 72 standards with daily testing near the aft gangway. Personnel support services require at least two toilet facilities (minimum one male and one female, or one per 25 personnel if ship facilities are unavailable), private-line telephones with local and long-distance access (if required), and secure broadband internet with minimum 25/5 Mbps speeds. Additional services include reserved marked NOAA parking as close as reasonably possible to the vessel, a general-purpose golf cart or utility vehicle with daily fuel/charging capability (if requested), equipped and climate-controlled dockside office space with toilets, and security guards on a COR-designated schedule.

View the file

Other files for this federal contract opportunity

Other files attached to FY27 NOAA Ship Gordon Gunter Drydock REFERENCES, newest first.
File Type Posted
Copy of 5100334-01_Salwico Cargo Addressable_Service Maintenance Manual_M_EN_2021_V.pdf PDF
150-6233566_RevJ_Sht1 THRU 6_N_A_MODULE NO. 9C STRL ASSY.pdf PDF
Copy of 5100332-01_Salwico Cargo Addressable_User Guide_M_EN_2021_ADx.pdf PDF
T9555-BA-MMO-010_0_0x.PDF PDF
Copy of TAGO_NONE_150-6233575_RevN_Sht1 THRU 13_N_A_MODULE NO. 10C STRUCTURAL ASSEMBLY.pdf PDF
Copy of m-202-instruction-manual-ocenco-inc.pdf PDF
GG Extinguisher List 5-28-25.xlsx XLSX spreadsheet
Steyr Motor Marine Engines SE SERIES 4 Cylinders 6 Cylinders Operation Maintenance and Warranty Manual P_N 707245 1st Edition February 2021..pdf PDF
Zodiac Hurricane H638 SOLAS Manual MB10247 Rev 11-8-2016.pdf PDF
GU-436-011Rev - Fire Detection Install_123880286.pdf PDF
529-6233819.pdf PDF
620-6233557.pdf PDF
NOAA Ships General Arrangement with camera locations (1).pdf PDF
GU_NONE_T0965-LP-109-1010_Rev1_Sht1 THRU 158_N_A_GU-KA-437-04 TANK LEVEL INDICATING TLI SYSTEM TYPE NO. 36000.pdf PDF
GU-555-001_-.pdf PDF
SFLC-Std-Spec-6310-(2020) - Requirements for Preservations of Ships Structures.pdf PDF
593-6233812.pdf PDF
1005-01 - NOAA Ship Health Plan (public).docx DOCX document
111-001.pdf PDF
NOAA Standard Specification 0000.1.docx.pdf PDF
437-6233672.pdf PDF
Drager Aerotest Navy Drager Tubes Pamphlet 9046651.pdf PDF
Gordon Gunter FY21 Cable Testing.xlsx XLSX spreadsheet
NOAA Ship Gordon Gunter Drawing Index List.xlsx XLSX spreadsheet
SSPC-SP-11-Power-Tool-To-Bare-Metal.pdf PDF
2 Bottle Vertical Inline Rack - UN_ISO Cylinders.pdf PDF
TECHNICAL PUBLICATIONS INDEX - SM638027 - 2203874.pdf PDF
524-6233951.pdf PDF
s1205.pdf PDF
NOAA Standard Specification AMC-300-1_Overhaul of Electrical Rotating Machinery.pdf PDF
SE_NONE_NONE_RevNONE_Sht1 OF 1_N_A_OS-342-6233813-1.pdf PDF
GU_NONE_GU-KA-568-01_RevNONE_Sht1 THRU 76_N_A_GU-KA-568-01 TUNNEL THRUSTER MODEL S-300-L SERIAL NOS. 86.000.435 AND 86.000.436.pdf PDF
Profile References Modules and Erection Sequence.docx DOCX document
90RMC050-D-610_REV- Carrier Operation and Maintenance Manual.pdf PDF
mk-line-2nd-1-26.pdf PDF
524-6233814 (1).pdf PDF
528-6233824.pdf PDF
6233762_G (1).PDF PDF
620-6233548.pdf PDF
GU_NONE_NONE_RevNONE_Sht1 THRU 2_N_A_GENERAL ARRANGEMENT MAIN DECK _ BELOW.pdf PDF
529-001 Revision A (1).pdf PDF
EconoAir General Arrangement Drawing.pdf PDF
E100 Rev -1 Gunter.pdf PDF
DD GU Reference 1 MOC-300-3_General_Requirements_for_Electrical_Electronic_Items_SEP_2000.pdf PDF
AMC-573-1C Weight Handling Gear Testing.pdf PDF
AMC-583-1B General Requirements for Liferaft Inspections.pdf PDF
GU-436-015 37442.03.01 - Connection drawings.pdf PDF
NOAA_Weight_Reporting_Spreadsheet.xlsx XLSX spreadsheet
NOAA Standard Specification 0863.0.docx.pdf PDF
SSPC-SP-1-Solvent-Wipe.pdf PDF
Show all 50

FY27 NOAA Ship Gordon Gunter Drydock REFERENCES has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOAA Standard Specification 0002.0

TEMPORARY SERVICES FOR CONTRACT WORK ON NOAA VESSELS

1.0 SCOPE

1.1 This item contains the requirements for temporary services to be provided to NOAA ship while at the Contractor's facility.

2.0 REFERENCES

2.1 ANSI C84.1 "Electric Power Systems and Equipment"

2.2 IEEE 519 (2014) "Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems"

2.3 IEEE C62.92.4 "IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part IV-Distribution"

2.4 NFPA 72 "National Fire Alarm and Signaling Code"

2.5 CFR 1915, Subpart F "OSHA Standards for Shipyard Employment, General Working Conditions"

2.6 29 CFR 1915.82 "OSHA Lighting Standards"

2.7 29 CFR 1918.22 "OSHA Safety for Longshoring, Gangways and Other Access"

3.0 DEFINITIONS

3.1 None.

4.0 REQUIREMENTS

4.1 Provide all required temporary services within two hours of ship arrival. Include cables, hoses, regulators, and restore services within one hour after interruptions.

4.2 Provide two OSHA-compliant gangways: one forward and one aft. Ensure lighting per OSHA 1915.82. Keep gangways and decks clear of ice and snow; avoid using salt-based deicers.

4.3 Provide fendering to prevent hull damage; repair any resulting damage.

4.4 Provide uncontaminated potable water via new hoses. Flush and verify compliance with SDWA.

4.5 Provide clean, regulated power per ANSI and IEEE standards. Ensure proper cabling and terminal compatibility.

4.6 Sanitary and cooling water services; Supply water to ship systems when drydocked.

4.7 Install a fire alarm system per NFPA 72 near aft gangway. Test daily and ensure reliability.

4.8 Provide pressure-tested fire water with hose trees and an emergency backup system with independent power supply.

4.9 Sewage and Turbid Water Disposal; accept and dispose of effluent from deck connections.

4.10 If required by the COR; supply steam per detailed specification using new hoses.

4.11 Provide one toilet per 25 personnel when ship facilities are not available. At a minimum there shall be 2 toilets (one male and one female).

4.12 If required by the COR, Install private-line telephones with local and long-distance access.

4.13 Provide secure broadband internet with minimum 25/5 Mbps speeds.

4.14 Garbage and Recycling Service, provide and clean disposal containers daily.

4.15 Vessel parking, reserve marked NOAA parking within or near the facility and as close as reasonably possible to the vessel.

4.16 If requested by the COR, provide a general-purpose golf cart or “gator” type vehicle for use at the Port Engineer’s discretion during the availability. Ensure fuel/charging capability for this vehicle is supplied daily.

4.17 Dockside Office Space, provide equipped, climate-controlled offices and toilets for NOAA use as close as reasonably possible to the vessel location.

4.18 Security Service. Provide guards at a schedule designated by the COR to secure the vessel when work is not being performed or during time when normal repair facilities are not onboard the vessel.

5.0 NOTES

5.1 None.